Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    698 vulnerabilities

    CVE-2026-9593 (GCVE-0-2026-9593)

    Vulnerability from cvelistv5 – Published: 2026-08-03 06:28 – Updated: 2026-08-03 14:44
    VLAI
    Title
    iDTM FDI Unauthorized Debug Interface Enablement
    Summary
    A vulnerability in the iDTM FDI allows an attacker with elevated privileges and access to the host system to enable the debug interface by placing a crafted file in the application directory, potentially resulting in unauthorized access to connected devices and exposure, modification, or disruption of device data or operation.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-427 - Uncontrolled Search Path Element
    Assigner
    References
    Impacted products
    Vendor Product Version
    Endress+Hauser FDI Package library Affected: 1.00.00 , < 2.01.00 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9593",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-03T14:33:33.859182Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-03T14:44:52.802Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FDI Package library",
              "vendor": "Endress+Hauser",
              "versions": [
                {
                  "lessThan": "2.01.00",
                  "status": "affected",
                  "version": "1.00.00",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:endress_hauser:fdi_package_library:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.01.00",
                      "versionStartIncluding": "1.00.00",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA vulnerability in the iDTM FDI allows an attacker with elevated privileges and access to the host system to enable the debug interface by placing a crafted file in the application directory, potentially resulting in unauthorized access to connected devices and exposure, modification, or disruption of device data or operation.\u003c/p\u003e"
                }
              ],
              "value": "A vulnerability in the iDTM FDI allows an attacker with elevated privileges and access to the host system to enable the debug interface by placing a crafted file in the application directory, potentially resulting in unauthorized access to connected devices and exposure, modification, or disruption of device data or operation."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-427",
                  "description": "CWE-427 Uncontrolled Search Path Element",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-03T06:28:19.769Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-065/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-065",
            "defect": [
              "CERT@VDE#642088"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "iDTM FDI Unauthorized Debug Interface Enablement",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-9593",
        "datePublished": "2026-08-03T06:28:19.769Z",
        "dateReserved": "2026-05-26T14:03:32.923Z",
        "dateUpdated": "2026-08-03T14:44:52.802Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-7849 (GCVE-0-2026-7849)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:54 – Updated: 2026-07-30 14:06
    VLAI
    Title
    Command Injection in SCM (idledisconnect parameter)
    Summary
    Due to improper neutralization of special elements, an unauthenticated remote attacker is able to inject a command into the system configuration which is subsequently executed as root.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-7849",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T14:06:34.517268Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T14:06:42.780Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eDue to improper neutralization of special elements, an unauthenticated remote attacker is able to inject a command into the system configuration which is subsequently executed as root.\u003c/p\u003e"
                }
              ],
              "value": "Due to improper neutralization of special elements, an unauthenticated remote attacker is able to inject a command into the system configuration which is subsequently executed as root."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:54:03.542Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Command Injection in SCM (idledisconnect parameter)",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-7849",
        "datePublished": "2026-07-30T06:54:03.542Z",
        "dateReserved": "2026-05-05T10:57:27.620Z",
        "dateUpdated": "2026-07-30T14:06:42.780Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44108 (GCVE-0-2026-44108)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:53 – Updated: 2026-07-30 12:59
    VLAI
    Title
    Firewall bypass during shutdown
    Summary
    Due to a flaw in the execution order of scripts during shutdown, the firewall is terminated prematurely during system shutdown. This creates a temporary window in which internal services may become externally accessible, potentially allowing an unauthenticated remote attacker to connect to these services, resulting in full system compromise.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-696 - Incorrect Behavior Order
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44108",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T12:56:52.796665Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T12:59:30.573Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eDue to a flaw in the execution order of scripts during shutdown, the firewall is terminated prematurely during system shutdown. This creates a temporary window in which internal services may become externally accessible, potentially allowing an unauthenticated remote attacker to connect to these services, resulting in full system compromise.\u003c/p\u003e"
                }
              ],
              "value": "Due to a flaw in the execution order of scripts during shutdown, the firewall is terminated prematurely during system shutdown. This creates a temporary window in which internal services may become externally accessible, potentially allowing an unauthenticated remote attacker to connect to these services, resulting in full system compromise."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-696",
                  "description": "CWE-696 Incorrect Behavior Order",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:53:42.718Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Firewall bypass during shutdown",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44108",
        "datePublished": "2026-07-30T06:53:42.718Z",
        "dateReserved": "2026-05-05T10:48:08.227Z",
        "dateUpdated": "2026-07-30T12:59:30.573Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44107 (GCVE-0-2026-44107)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:53 – Updated: 2026-07-30 15:16
    VLAI
    Title
    Exposed Reboot via Modbus
    Summary
    A reboot of the charging controller can be triggered via Modbus TCP without authentication. Therefore, when the Modbus functionality is enabled by opening the port that CharxModbusServer is listening, an unauthenticated attacker can perform a Denial-of-Service attack.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-749 - Exposed Dangerous Method or Function
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44107",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T15:13:19.629103Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T15:16:52.455Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA reboot of the charging controller can be triggered via Modbus TCP without authentication. Therefore, when the Modbus functionality is enabled by opening the port that CharxModbusServer is listening, an unauthenticated attacker can perform a Denial-of-Service attack.\u003c/p\u003e"
                }
              ],
              "value": "A reboot of the charging controller can be triggered via Modbus TCP without authentication. Therefore, when the Modbus functionality is enabled by opening the port that CharxModbusServer is listening, an unauthenticated attacker can perform a Denial-of-Service attack."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-749",
                  "description": "CWE-749 Exposed Dangerous Method or Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:53:28.559Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Exposed Reboot via Modbus",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44107",
        "datePublished": "2026-07-30T06:53:28.559Z",
        "dateReserved": "2026-05-05T10:48:08.227Z",
        "dateUpdated": "2026-07-30T15:16:52.455Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44105 (GCVE-0-2026-44105)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:53 – Updated: 2026-07-30 12:28
    VLAI
    Title
    Cleartext password in logs
    Summary
    The credentials for the local user "user-app" may be exposed in log files, potentially enabling a low-privileged local attacker with access to the logs to authenticate via SSH as the limited user "user-app". Charging could be interrupted.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-532 - Insertion of Sensitive Information into Log File
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44105",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T12:28:28.043093Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T12:28:47.946Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe credentials for the local user \u0026quot;user-app\u0026quot; may be exposed in log files, potentially enabling a low-privileged local attacker with access to the logs to authenticate via SSH as the limited user \u0026quot;user-app\u0026quot;. Charging could be interrupted.\u003c/p\u003e"
                }
              ],
              "value": "The credentials for the local user \"user-app\" may be exposed in log files, potentially enabling a low-privileged local attacker with access to the logs to authenticate via SSH as the limited user \"user-app\". Charging could be interrupted."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 5.8,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-532",
                  "description": "CWE-532 Insertion of Sensitive Information into Log File",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:53:13.068Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Cleartext password in logs",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44105",
        "datePublished": "2026-07-30T06:53:13.068Z",
        "dateReserved": "2026-05-05T10:48:08.227Z",
        "dateUpdated": "2026-07-30T12:28:47.946Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44106 (GCVE-0-2026-44106)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:52 – Updated: 2026-07-31 22:47
    VLAI
    Title
    Local Privilege Escalation vulnerability in /etc/init.d/user-applications via customer website file
    Summary
    A privilege escalation vulnerability in the init-script for user-applications allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44106",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-31T22:47:02.500187Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-31T22:47:27.002Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA privilege escalation vulnerability in the init-script for user-applications allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.\u003c/p\u003e"
                }
              ],
              "value": "A privilege escalation vulnerability in the init-script for user-applications allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:52:58.069Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Local Privilege Escalation vulnerability in /etc/init.d/user-applications via customer website file",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44106",
        "datePublished": "2026-07-30T06:52:58.069Z",
        "dateReserved": "2026-05-05T10:48:08.227Z",
        "dateUpdated": "2026-07-31T22:47:27.002Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44104 (GCVE-0-2026-44104)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:52 – Updated: 2026-07-30 14:05
    VLAI
    Title
    ControllerAgent does not perform validation of firmware
    Summary
    The firmware update process for the basemodule of the charging controller only validates the CRC32 checksum without cryptographic signature verification. This allows an unauthenticated remote attacker to install a modified firmware, resulting in full system compromise.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-347 - Improper Verification of Cryptographic Signature
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44104",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T14:05:30.366585Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T14:05:46.344Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe firmware update process for the basemodule of the charging controller only validates the\nCRC32 checksum without cryptographic signature verification. This allows an unauthenticated remote attacker to install a modified firmware, resulting in full system compromise.\u003c/p\u003e"
                }
              ],
              "value": "The firmware update process for the basemodule of the charging controller only validates the\nCRC32 checksum without cryptographic signature verification. This allows an unauthenticated remote attacker to install a modified firmware, resulting in full system compromise."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-347",
                  "description": "CWE-347 Improper Verification of Cryptographic Signature",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:52:31.346Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "ControllerAgent does not perform validation of firmware",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44104",
        "datePublished": "2026-07-30T06:52:31.346Z",
        "dateReserved": "2026-05-05T10:48:08.226Z",
        "dateUpdated": "2026-07-30T14:05:46.344Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44103 (GCVE-0-2026-44103)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:52 – Updated: 2026-07-30 12:56
    VLAI
    Title
    JupiCore does not perform validation of firmware
    Summary
    An unauthenticated remote attacker can inject malicious firmware into the internal charging module because the JupiCore service transmits firmware updates without performing integrity or verification check. Successful exploitation may compromise the integrity of the affected device. This vulnerability could be used in chain with CVE-2026-44104.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-434 - Unrestricted Upload of File with Dangerous Type
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44103",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T12:56:30.769176Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T12:56:38.642Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn unauthenticated remote attacker can inject malicious firmware into the internal charging module because the JupiCore service transmits firmware updates without performing integrity or verification check. Successful exploitation may compromise the integrity of the affected device. This vulnerability could be used in chain with CVE-2026-44104.\u003c/p\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker can inject malicious firmware into the internal charging module because the JupiCore service transmits firmware updates without performing integrity or verification check. Successful exploitation may compromise the integrity of the affected device. This vulnerability could be used in chain with CVE-2026-44104."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:52:07.531Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "JupiCore does not perform validation of firmware",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44103",
        "datePublished": "2026-07-30T06:52:07.531Z",
        "dateReserved": "2026-05-05T10:48:08.226Z",
        "dateUpdated": "2026-07-30T12:56:38.642Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44102 (GCVE-0-2026-44102)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:51 – Updated: 2026-07-30 15:16
    VLAI
    Title
    OCPP Firmware download is not properly locked
    Summary
    An unauthenticated remote attacker can trigger a firmware update download via the OCPP backend by supplying an invalid firmware file. This will cause the file to remain accessible for a short period before it is deleted due to improper locking during the cleanup process.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-362 - Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44102",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T15:12:48.143130Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T15:16:59.628Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn unauthenticated remote attacker can trigger a firmware update download via the OCPP backend by supplying an invalid firmware file. This will cause the file to remain accessible for a short period before it is deleted due to improper locking during the cleanup process.\u003c/p\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker can trigger a firmware update download via the OCPP backend by supplying an invalid firmware file. This will cause the file to remain accessible for a short period before it is deleted due to improper locking during the cleanup process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-362",
                  "description": "CWE-362 Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:51:42.011Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "OCPP Firmware download is not properly locked",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44102",
        "datePublished": "2026-07-30T06:51:42.011Z",
        "dateReserved": "2026-05-05T10:48:08.226Z",
        "dateUpdated": "2026-07-30T15:16:59.628Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44101 (GCVE-0-2026-44101)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:51 – Updated: 2026-07-31 22:46
    VLAI
    Title
    OCPP reconfiguration vulnerability
    Summary
    Due to missing authentication the CHARX OCPP Agent service allows an unauthenticated remote attacker to reconfigure the backend connection. This can lead to Denial-of-Service and confidential data being disclosed to the attacker.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44101",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-31T22:45:41.515538Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-31T22:46:01.757Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eDue to missing authentication the CHARX OCPP Agent service allows an unauthenticated remote attacker to reconfigure the backend connection. This can lead to Denial-of-Service and confidential data being disclosed to the attacker.\u003c/p\u003e"
                }
              ],
              "value": "Due to missing authentication the CHARX OCPP Agent service allows an unauthenticated remote attacker to reconfigure the backend connection. This can lead to Denial-of-Service and confidential data being disclosed to the attacker."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:51:09.276Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "OCPP reconfiguration vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44101",
        "datePublished": "2026-07-30T06:51:09.276Z",
        "dateReserved": "2026-05-05T10:48:08.226Z",
        "dateUpdated": "2026-07-31T22:46:01.757Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44100 (GCVE-0-2026-44100)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:50 – Updated: 2026-07-30 12:29
    VLAI
    Title
    JupiCore charging point reconfiguration without auth
    Summary
    The CHARX JupiCore service allows an unauthenticated remote attacker to reconfigure charging points. This can lead to disclosure of charging point UIDs, Denial-of-Service and files tampering.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44100",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T12:29:18.710238Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T12:29:40.648Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe CHARX JupiCore service allows an unauthenticated remote attacker to reconfigure charging points. This can lead to disclosure of charging point UIDs, Denial-of-Service and files tampering.\u003c/p\u003e"
                }
              ],
              "value": "The CHARX JupiCore service allows an unauthenticated remote attacker to reconfigure charging points. This can lead to disclosure of charging point UIDs, Denial-of-Service and files tampering."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:50:41.583Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "JupiCore charging point reconfiguration without auth",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44100",
        "datePublished": "2026-07-30T06:50:41.583Z",
        "dateReserved": "2026-05-05T10:48:08.226Z",
        "dateUpdated": "2026-07-30T12:29:40.648Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44099 (GCVE-0-2026-44099)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:50 – Updated: 2026-07-30 14:09
    VLAI
    Title
    Local Privilege Escalation via pppd password injection
    Summary
    A privilege escalation vulnerability in the system configuration allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44099",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T14:07:24.229416Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T14:09:31.734Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA privilege escalation vulnerability in the system configuration allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.\u003c/p\u003e"
                }
              ],
              "value": "A privilege escalation vulnerability in the system configuration allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:50:08.946Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Local Privilege Escalation via pppd password injection",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44099",
        "datePublished": "2026-07-30T06:50:08.946Z",
        "dateReserved": "2026-05-05T10:48:08.226Z",
        "dateUpdated": "2026-07-30T14:09:31.734Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44098 (GCVE-0-2026-44098)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:49 – Updated: 2026-07-30 12:56
    VLAI
    Title
    OS Command Injection in OCPP Agent via charge_box_id
    Summary
    This vulnerability allows an unauthenticated remote attacker with control over the OCPP backend via firewall-bypass to perform an OS command injection, resulting in the execution of arbitrary commands as the limited user charx-oa. Charging could be interrupted.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44098",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T12:56:06.191535Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T12:56:14.535Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThis vulnerability allows an unauthenticated remote attacker with control over the OCPP backend via firewall-bypass to perform an OS command injection, resulting in the execution of arbitrary commands as the  limited user charx-oa. Charging could be interrupted.\u003c/p\u003e"
                }
              ],
              "value": "This vulnerability allows an unauthenticated remote attacker with control over the OCPP backend via firewall-bypass to perform an OS command injection, resulting in the execution of arbitrary commands as the  limited user charx-oa. Charging could be interrupted."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:49:53.260Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "OS Command Injection in OCPP Agent via charge_box_id",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44098",
        "datePublished": "2026-07-30T06:49:53.260Z",
        "dateReserved": "2026-05-05T10:48:08.226Z",
        "dateUpdated": "2026-07-30T12:56:14.535Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44097 (GCVE-0-2026-44097)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:49 – Updated: 2026-07-30 15:17
    VLAI
    Title
    File Upload vulnerability
    Summary
    A low-privileged remote attacker with "operator" access can upload arbitrary files via the REST endpoint intended for firmware updates, resulting in persistent storage of attacker-controlled files and potentially exhausting resources, which might lead to Denial-of-Service.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-434 - Unrestricted Upload of File with Dangerous Type
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44097",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T15:12:31.352458Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T15:17:09.218Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA low-privileged remote attacker with \u0026quot;operator\u0026quot; access can upload arbitrary files via the REST endpoint intended for firmware updates, resulting in persistent storage of attacker-controlled files and potentially exhausting resources, which might lead to Denial-of-Service.\u003c/p\u003e"
                }
              ],
              "value": "A low-privileged remote attacker with \"operator\" access can upload arbitrary files via the REST endpoint intended for firmware updates, resulting in persistent storage of attacker-controlled files and potentially exhausting resources, which might lead to Denial-of-Service."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:49:34.687Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "File Upload vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44097",
        "datePublished": "2026-07-30T06:49:34.687Z",
        "dateReserved": "2026-05-05T10:48:08.226Z",
        "dateUpdated": "2026-07-30T15:17:09.218Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44096 (GCVE-0-2026-44096)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:49 – Updated: 2026-07-31 22:45
    VLAI
    Title
    udhcpc Privilege Escalation
    Summary
    A privilege escalation vulnerability in udhcpc allows a local user "charx-web" to execute arbitrary commands as root, resulting in full system compromise.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44096",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-31T22:44:52.933019Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-31T22:45:06.024Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA privilege escalation vulnerability in udhcpc allows a local user \u0026quot;charx-web\u0026quot; to execute arbitrary commands as root, resulting in full system compromise.\u003c/p\u003e"
                }
              ],
              "value": "A privilege escalation vulnerability in udhcpc allows a local user \"charx-web\" to execute arbitrary commands as root, resulting in full system compromise."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:49:16.576Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "udhcpc Privilege Escalation",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44096",
        "datePublished": "2026-07-30T06:49:16.576Z",
        "dateReserved": "2026-05-05T10:48:08.226Z",
        "dateUpdated": "2026-07-31T22:45:06.024Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44095 (GCVE-0-2026-44095)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:48 – Updated: 2026-07-30 12:32
    VLAI
    Title
    Local Privilege Escalation via Network scripts
    Summary
    A privilege escalation vulnerability in a script used for network configuration allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44095",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T12:32:40.171249Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T12:32:56.327Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA privilege escalation vulnerability in a script used for network configuration allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.\u003c/p\u003e"
                }
              ],
              "value": "A privilege escalation vulnerability in a script used for network configuration allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:48:55.750Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Local Privilege Escalation via Network scripts",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44095",
        "datePublished": "2026-07-30T06:48:55.750Z",
        "dateReserved": "2026-05-05T10:48:08.226Z",
        "dateUpdated": "2026-07-30T12:32:56.327Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44094 (GCVE-0-2026-44094)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:48 – Updated: 2026-07-30 14:04
    VLAI
    Title
    Fallback to second RAUC slot with default credentials
    Summary
    An unauthenticated remote attacker can enforce the system to fall back to a firmware partition with an insecure configuration including default credentials. This could allow the attacker to gain SSH access to the system as an unprivileged user "user-app". Charging could be interrupted.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-636 - Not Failing Securely ('Failing Open')
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44094",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T14:03:15.366786Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T14:04:15.872Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn unauthenticated remote attacker can enforce the system to fall back to a firmware partition with an insecure configuration including default credentials. This could allow the attacker to gain SSH access to the system as an unprivileged user \u0026quot;user-app\u0026quot;. Charging could be interrupted.\u003c/p\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker can enforce the system to fall back to a firmware partition with an insecure configuration including default credentials. This could allow the attacker to gain SSH access to the system as an unprivileged user \"user-app\". Charging could be interrupted."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-636",
                  "description": "CWE-636 Not Failing Securely (\u0027Failing Open\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:48:37.951Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Fallback to second RAUC slot with default credentials",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44094",
        "datePublished": "2026-07-30T06:48:37.951Z",
        "dateReserved": "2026-05-05T10:48:08.226Z",
        "dateUpdated": "2026-07-30T14:04:15.872Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44093 (GCVE-0-2026-44093)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:48 – Updated: 2026-07-30 12:55
    VLAI
    Title
    Local Privilege Escalation vulnerability in /etc/init.d/user-applications via user-application start script
    Summary
    A local privilege escalation vulnerability in the init-script for user-applications allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44093",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T12:55:32.839061Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T12:55:41.446Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA local privilege escalation vulnerability in the init-script for user-applications allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.\u003c/p\u003e"
                }
              ],
              "value": "A local privilege escalation vulnerability in the init-script for user-applications allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:48:19.608Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Local Privilege Escalation vulnerability in /etc/init.d/user-applications via user-application start script",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44093",
        "datePublished": "2026-07-30T06:48:19.608Z",
        "dateReserved": "2026-05-05T10:48:08.226Z",
        "dateUpdated": "2026-07-30T12:55:41.446Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44092 (GCVE-0-2026-44092)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:47 – Updated: 2026-07-30 15:17
    VLAI
    Title
    Missing input validation / stripping of CRLF characters in SystemConfigManager
    Summary
    An unauthenticated remote attacker can inject malicious input into the ModbusServer application because it does not validate the input it fetches from MQTT. This may lead to integrity and availability loss.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-93 - Improper Neutralization of CRLF Sequences ('CRLF Injection')
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44092",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T14:38:20.576283Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T15:17:18.110Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn unauthenticated remote attacker can inject malicious input into the ModbusServer application because it does not validate the input it fetches from MQTT. This may lead to integrity and availability loss.\u003c/p\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker can inject malicious input into the ModbusServer application because it does not validate the input it fetches from MQTT. This may lead to integrity and availability loss."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-93",
                  "description": "CWE-93 Improper Neutralization of CRLF Sequences (\u0027CRLF Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:47:57.320Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Missing input validation / stripping of CRLF characters in SystemConfigManager",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44092",
        "datePublished": "2026-07-30T06:47:57.320Z",
        "dateReserved": "2026-05-05T10:48:08.226Z",
        "dateUpdated": "2026-07-30T15:17:18.110Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44091 (GCVE-0-2026-44091)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:47 – Updated: 2026-07-31 22:44
    VLAI
    Title
    Creation of a new configuration by posting a malicious ID to MQTT
    Summary
    An unauthenticated remote attacker can post a malicious ID to the MQTT Broker results in the creation of a new configuration entry in the system configuration. This may lead to integrity and availability loss.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-501 - Trust Boundary Violation
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44091",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-31T22:43:51.147978Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-31T22:44:06.392Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn unauthenticated remote attacker can post a malicious ID to the MQTT Broker results in the creation of a new configuration entry in the system configuration. This may lead to integrity and availability loss.\u003c/p\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker can post a malicious ID to the MQTT Broker results in the creation of a new configuration entry in the system configuration. This may lead to integrity and availability loss."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-501",
                  "description": "CWE-501 Trust Boundary Violation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:47:37.456Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Creation of a new configuration by posting a malicious ID to MQTT",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44091",
        "datePublished": "2026-07-30T06:47:37.456Z",
        "dateReserved": "2026-05-05T10:48:08.225Z",
        "dateUpdated": "2026-07-31T22:44:06.392Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44090 (GCVE-0-2026-44090)

    Vulnerability from cvelistv5 – Published: 2026-07-30 06:47 – Updated: 2026-07-30 12:34
    VLAI
    Title
    Missing authentication for MQTT Broker
    Summary
    Due to missing authentication, an unauthenticated remote attacker may access the MQTT broker, which is only protected from external access by a firewall. This may lead to the device being fully compromised.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Credits
    ZDI
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-44090",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-30T12:33:53.011898Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-30T12:34:08.064Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3150",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3100",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3050",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CHARX SEC-3000",
              "vendor": "Phoenix Contact",
              "versions": [
                {
                  "lessThan": "1.9.1",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3150:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3100:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3050:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:phoenix_contact:charx_sec_3000:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.9.1",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ZDI"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eDue to missing authentication, an unauthenticated remote attacker may access the MQTT broker, which is only protected from external access by a firewall. This may lead to the device being fully compromised.\u003c/p\u003e"
                }
              ],
              "value": "Due to missing authentication, an unauthenticated remote attacker may access the MQTT broker, which is only protected from external access by a firewall. This may lead to the device being fully compromised."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-30T06:47:04.767Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-008/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-008",
            "defect": [
              "CERT@VDE#641939"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Missing authentication for MQTT Broker",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-44090",
        "datePublished": "2026-07-30T06:47:04.767Z",
        "dateReserved": "2026-05-05T10:48:08.225Z",
        "dateUpdated": "2026-07-30T12:34:08.064Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-35226 (GCVE-0-2026-35226)

    Vulnerability from cvelistv5 – Published: 2026-07-29 07:05 – Updated: 2026-07-29 14:27
    VLAI
    Title
    Out-of-bounds Write in CODESYS PROFINET Controller
    Summary
    An out‑of‑bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime system and results in a controlled stop of the PLC application.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    CODESYS CODESYS PROFINET Affected: 4.4.0.0 , < 4.8.0.0 (semver)
    Create a notification for this product.
    Credits
    ABB
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-35226",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-29T14:27:26.242820Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-29T14:27:45.179Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS PROFINET",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.8.0.0",
                  "status": "affected",
                  "version": "4.4.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:codesys:codesys_profinet:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "4.8.0.0",
                      "versionStartIncluding": "4.4.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn out\u2011of\u2011bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime system and results in a controlled stop of the PLC application.\u003c/p\u003e"
                }
              ],
              "value": "An out\u2011of\u2011bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime system and results in a controlled stop of the PLC application."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-29T07:05:57.508Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-041/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-041",
            "defect": [
              "CERT@VDE#642012"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Out-of-bounds Write in CODESYS PROFINET Controller",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-35226",
        "datePublished": "2026-07-29T07:05:57.508Z",
        "dateReserved": "2026-04-01T19:54:21.499Z",
        "dateUpdated": "2026-07-29T14:27:45.179Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-16462 (GCVE-0-2026-16462)

    Vulnerability from cvelistv5 – Published: 2026-07-28 09:27 – Updated: 2026-07-28 19:15
    VLAI
    Title
    SQL injection via unauthenticated GetGridData endpoint
    Summary
    In PROCON-WEB SCADA the endpoint 'GetGridData' is not properly sanitized. This allows a remote unauthenticated attacker to execute arbitrary SQL commands.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Weidmueller Interface PROCON-WEB SCADA Affected: 1.0.0 , ≤ 6.11.2 (semver)
    Create a notification for this product.
    Credits
    Marcel Fromkorth (8com)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-16462",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-28T19:15:31.024410Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-28T19:15:38.784Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PROCON-WEB SCADA",
              "vendor": "Weidmueller Interface",
              "versions": [
                {
                  "lessThanOrEqual": "6.11.2",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:weidmueller:procon_web_scada:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "6.11.2",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Marcel Fromkorth (8com)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eIn PROCON-WEB SCADA the endpoint \u0027GetGridData\u0027 is not properly sanitized. This allows a remote unauthenticated attacker to execute arbitrary SQL commands.\u003c/p\u003e"
                }
              ],
              "value": "In PROCON-WEB SCADA the endpoint \u0027GetGridData\u0027 is not properly sanitized. This allows a remote unauthenticated attacker to execute arbitrary SQL commands."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-28T09:27:22.755Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-085/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-085",
            "defect": [
              "CERT@VDE#642183"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "SQL injection via unauthenticated GetGridData endpoint",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-16462",
        "datePublished": "2026-07-28T09:27:22.755Z",
        "dateReserved": "2026-07-21T11:56:03.095Z",
        "dateUpdated": "2026-07-28T19:15:38.784Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-14171 (GCVE-0-2026-14171)

    Vulnerability from cvelistv5 – Published: 2026-07-28 09:08 – Updated: 2026-07-28 15:19
    VLAI
    Title
    ads-tec Industrial IT: Post-login open redirect in the web interface
    Summary
    An unauthenticated remote attacker can abuse the improper validation of the post-login redirect of the web-UI to trick users to a malicious website. This can result in a loss of confidentiality and availability.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-601 - URL Redirection to Untrusted Site ('Open Redirect')
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-14171",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-28T15:19:13.977120Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-28T15:19:52.672Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF1401",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "2.2.5",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF1421",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "2.2.5",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3401",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "2.2.5",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3421",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "2.2.5",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3801",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "2.2.5",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3821",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "2.2.5",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf1000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "2.2.5",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf1000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "2.2.5",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "2.2.5",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "2.2.5",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "2.2.5",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "2.2.5",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn unauthenticated remote attacker can abuse the improper validation of the post-login redirect  of the web-UI to trick users to a malicious website. This can result in a loss of confidentiality and availability.\u003c/p\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker can abuse the improper validation of the post-login redirect  of the web-UI to trick users to a malicious website. This can result in a loss of confidentiality and availability."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-601",
                  "description": "CWE-601 URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-28T09:08:09.315Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-076/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-076",
            "defect": [
              "CERT@VDE#642153"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "ads-tec Industrial IT: Post-login open redirect in the web interface",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-14171",
        "datePublished": "2026-07-28T09:08:09.315Z",
        "dateReserved": "2026-06-30T06:39:09.811Z",
        "dateUpdated": "2026-07-28T15:19:52.672Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-14169 (GCVE-0-2026-14169)

    Vulnerability from cvelistv5 – Published: 2026-07-28 09:07 – Updated: 2026-07-28 13:59
    VLAI
    Title
    ads-tec Industrial IT: Account lockout via non-atomic user creation
    Summary
    Due to incorrect behavior order a low privileged remote attacker could trigger account inconsistent state via crafted input and overwrites existing user passwords which could result in complete administrative unavailability of the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-696 - Incorrect Behavior Order
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-14169",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-28T13:59:08.929622Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-28T13:59:20.151Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF1401",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF1421",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3401",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3421",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3801",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3821",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf1000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf1000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eDue to incorrect behavior order a low privileged remote attacker could trigger account inconsistent state via crafted input and overwrites existing user passwords which could result in complete administrative unavailability of the device.\u003c/p\u003e"
                }
              ],
              "value": "Due to incorrect behavior order a low privileged remote attacker could trigger account inconsistent state via crafted input and overwrites existing user passwords which could result in complete administrative unavailability of the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-696",
                  "description": "CWE-696 Incorrect Behavior Order",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-28T09:07:36.032Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-076/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-076",
            "defect": [
              "CERT@VDE#642153"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "ads-tec Industrial IT: Account lockout via non-atomic user creation",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-14169",
        "datePublished": "2026-07-28T09:07:36.032Z",
        "dateReserved": "2026-06-30T06:39:07.206Z",
        "dateUpdated": "2026-07-28T13:59:20.151Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-14168 (GCVE-0-2026-14168)

    Vulnerability from cvelistv5 – Published: 2026-07-28 09:07 – Updated: 2026-07-28 12:46
    VLAI
    Title
    ads-tec Industrial IT: Vertical privilege escalation via configuration table write
    Summary
    A low privileged remote attacker can gain administrator privileges due to missing authorization at the insert path of the configuration table resulting in gaining full system access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-14168",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-28T12:45:27.040730Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-28T12:46:30.943Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF1401",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF1421",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3401",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3421",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3801",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3821",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf1000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf1000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA low privileged remote attacker can gain administrator privileges due to missing authorization at the insert path of the configuration table resulting in gaining full system access.\u003c/p\u003e"
                }
              ],
              "value": "A low privileged remote attacker can gain administrator privileges due to missing authorization at the insert path of the configuration table resulting in gaining full system access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "CWE-862 Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-28T09:07:26.723Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-076/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-076",
            "defect": [
              "CERT@VDE#642153"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "ads-tec Industrial IT: Vertical privilege escalation via configuration table write",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-14168",
        "datePublished": "2026-07-28T09:07:26.723Z",
        "dateReserved": "2026-06-30T06:39:05.718Z",
        "dateUpdated": "2026-07-28T12:46:30.943Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-14167 (GCVE-0-2026-14167)

    Vulnerability from cvelistv5 – Published: 2026-07-28 09:06 – Updated: 2026-07-28 13:29
    VLAI
    Title
    ads-tec Industrial IT: Privilege escalation during configuration import
    Summary
    A low privileged remote attacker can perform privileged configuration changes reserved for the administrator level including permission management due to incorrect authorization.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-14167",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-28T13:29:43.480793Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-28T13:29:55.370Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF1401",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF1421",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3401",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3421",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3801",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DVG-IRF3821",
              "vendor": "ads-tec Industrial IT",
              "versions": [
                {
                  "lessThan": "2.3.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf1000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf1000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:ads_tec:irf3000_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.3.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA low privileged remote attacker can perform privileged configuration changes reserved for the administrator level including permission management due to incorrect authorization.\u003c/p\u003e"
                }
              ],
              "value": "A low privileged remote attacker can perform privileged configuration changes reserved for the administrator level including permission management due to incorrect authorization."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863 Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-28T09:06:01.009Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-076/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-076",
            "defect": [
              "CERT@VDE#642153"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "ads-tec Industrial IT: Privilege escalation during configuration import",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-14167",
        "datePublished": "2026-07-28T09:06:01.009Z",
        "dateReserved": "2026-06-30T06:39:03.547Z",
        "dateUpdated": "2026-07-28T13:29:55.370Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-14837 (GCVE-0-2026-14837)

    Vulnerability from cvelistv5 – Published: 2026-07-27 07:03 – Updated: 2026-07-27 14:01
    VLAI
    Title
    SSH Enablement Signature Verification Bypass
    Summary
    Multiple Lenze products are affected by an improper signature verification vulnerability in the SSH enablement mechanism. A low-privileged local attacker can bypass verification of the SSH enable file signature and enable SSH access on the device. Successful exploitation may result in unauthorized administrative access and complete system compromise.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-347 - Improper Verification of Cryptographic Signature
    Assigner
    References
    Impacted products
    Vendor Product Version
    Lenze c430 Affected: 1.0.0 , < 1.15.2 (semver)
    Create a notification for this product.
    Lenze c520 Affected: 1.0.0 , < 1.15.2 (semver)
    Create a notification for this product.
    Lenze c550 Affected: 1.0.0 , < 1.15.2 (semver)
    Create a notification for this product.
    Lenze i950 GenA Affected: 1.0.0 , < 1.14.2 (semver)
    Create a notification for this product.
    Lenze i950 GenB Affected: 2.0.0 , < 2.0.3 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-14837",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-27T14:01:41.585468Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-27T14:01:50.573Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "c430",
              "vendor": "Lenze",
              "versions": [
                {
                  "lessThan": "1.15.2",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "c520",
              "vendor": "Lenze",
              "versions": [
                {
                  "lessThan": "1.15.2",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "c550",
              "vendor": "Lenze",
              "versions": [
                {
                  "lessThan": "1.15.2",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "i950 GenA",
              "vendor": "Lenze",
              "versions": [
                {
                  "lessThan": "1.14.2",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "i950 GenB",
              "vendor": "Lenze",
              "versions": [
                {
                  "lessThan": "2.0.3",
                  "status": "affected",
                  "version": "2.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:lenze:c4xx_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.15.2",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:lenze:c5xx_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.15.2",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:lenze:c5xx_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.15.2",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:lenze:i950_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "1.14.2",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:lenze:i950_firmware:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.0.3",
                      "versionStartIncluding": "2.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eMultiple Lenze products are affected by an improper signature verification vulnerability in the SSH enablement mechanism. A low-privileged local attacker can bypass verification of the SSH enable file signature and enable SSH access on the device. Successful exploitation may result in unauthorized administrative access and complete system compromise.\u003c/p\u003e"
                }
              ],
              "value": "Multiple Lenze products are affected by an improper signature verification vulnerability in the SSH enablement mechanism. A low-privileged local attacker can bypass verification of the SSH enable file signature and enable SSH access on the device. Successful exploitation may result in unauthorized administrative access and complete system compromise."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-347",
                  "description": "CWE-347 Improper Verification of Cryptographic Signature",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-27T07:03:27.889Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-077/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-077",
            "defect": [
              "CERT@VDE#642156"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "SSH Enablement Signature Verification Bypass",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-14837",
        "datePublished": "2026-07-27T07:03:27.889Z",
        "dateReserved": "2026-07-06T09:59:37.390Z",
        "dateUpdated": "2026-07-27T14:01:50.573Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-14448 (GCVE-0-2026-14448)

    Vulnerability from cvelistv5 – Published: 2026-07-20 11:40 – Updated: 2026-07-20 13:52
    VLAI
    Title
    Authenticated RCE in system_certificates view
    Summary
    An high privileged remote attacker can exploit an authenticated OS command injection vulnerability in the system_certificates view due to improper neutralization of special elements in an OS command. This can result in a total loss of confidentiality, availability and integrity.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-14448",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-20T13:52:15.023741Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-20T13:52:32.818Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.20.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "lessThanOrEqual": "2.20.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.20.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "mymbCONNECT24",
              "vendor": "MB connect line",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.20.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24V2",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.20.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24V2.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "lessThanOrEqual": "2.20.0",
                  "status": "affected",
                  "version": "1.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24V2",
              "vendor": "Helmholz",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.20.0"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "myREX24V2.virtual",
              "vendor": "Helmholz",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.20.0"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:mb_connect_line:mbconnect24:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "2.20.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:mb_connect_line:mymbconnect24:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "2.20.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:mb_connect_line:mbconnect24:2.20.0:*:*:*:*:*:*:*",
                      "versionStartIncluding": "2.20.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:mb_connect_line:mymbconnect24:2.20.0:*:*:*:*:*:*:*",
                      "versionStartIncluding": "2.20.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:helmholz:myrex24v2:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "2.20.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:helmholz:myrex24v2.virtual:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "2.20.0",
                      "versionStartIncluding": "1.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:helmholz:myrex24v2:2.20.0:*:*:*:*:*:*:*",
                      "versionStartIncluding": "2.20.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            },
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:o:helmholz:myrex24v2virtual:2.20.0:*:*:*:*:*:*:*",
                      "versionStartIncluding": "2.20.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn high privileged remote attacker can exploit an authenticated OS command injection vulnerability in the system_certificates view due to improper neutralization of special elements in an OS command. This can result in a total loss of confidentiality, availability and integrity.\u003c/p\u003e"
                }
              ],
              "value": "An high privileged remote attacker can exploit an authenticated OS command injection vulnerability in the system_certificates view due to improper neutralization of special elements in an OS command. This can result in a total loss of confidentiality, availability and integrity."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-20T11:40:50.055Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-044/"
            },
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-058/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-044, VDE-2026-058",
            "defect": [
              "CERT@VDE#642025"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Authenticated RCE in system_certificates view",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-14448",
        "datePublished": "2026-07-20T11:40:50.055Z",
        "dateReserved": "2026-07-02T07:14:32.098Z",
        "dateUpdated": "2026-07-20T13:52:32.818Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2023-49899 (GCVE-0-2023-49899)

    Vulnerability from cvelistv5 – Published: 2026-07-16 10:11 – Updated: 2026-07-18 02:46
    VLAI
    Title
    Origin Validation Error in X-Rite MA-T6
    Summary
    An unauthenticated remote attacker can execute any command on the affected device due to not correctly verifying the origin of a communication channel.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-346 - Origin Validation Error
    Assigner
    References
    Impacted products
    Vendor Product Version
    X-Rite MA-T6 Affected: 0 , < v2.33 (custom)
    Create a notification for this product.
    Date Public
    2023-12-23 10:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-49899",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-18T02:45:55.345300Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-18T02:46:07.283Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "MA-T6",
              "vendor": "X-Rite",
              "versions": [
                {
                  "lessThan": "v2.33",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:x-rite:ma-t6:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "v2.33",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "datePublic": "2023-12-23T10:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker can\u0026nbsp;execute any command on the affected device due to not correctly verifying the origin of a communication channel."
                }
              ],
              "value": "An unauthenticated remote attacker can\u00a0execute any command on the affected device due to not correctly verifying the origin of a communication channel."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-346",
                  "description": "CWE-346 Origin Validation Error",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-16T10:11:32.404Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "related"
              ],
              "url": "https://claroty.com/team82/disclosure-dashboard/cve-2023-49899"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#642027"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Origin Validation Error in X-Rite MA-T6",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-49899",
        "datePublished": "2026-07-16T10:11:32.404Z",
        "dateReserved": "2023-12-01T08:19:11.319Z",
        "dateUpdated": "2026-07-18T02:46:07.283Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }