    CVE-2026-89207 (GCVE-0-2026-89207)

    Vulnerability from cvelistv5 – Published: 2026-09-16 07:59 – Updated: 2026-09-16 18:13
    VLAI
    Summary
    A vulnerability has been identified in WTV676-HB6035 Web Interface (All versions < V3.94), WTV776-HB6035 Web Interface (All versions < V4.17). Affected devices do not properly validate input received from backend services. This could allow an unauthenticated remote attacker to force the device into protection mode, which results in losing remote connectivity functions (Web Access).
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-16 18:13 UTC
    CWE
    • CWE-1287 - Improper Validation of Specified Type of Input
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-89207",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-16T18:13:09.211468Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-16T18:13:23.189Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "WTV676-HB6035 Web Interface",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.94",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "WTV776-HB6035 Web Interface",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.17",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in WTV676-HB6035 Web Interface (All versions \u003c V3.94), WTV776-HB6035 Web Interface (All versions \u003c V4.17). Affected devices do not properly validate input received from backend services.\r\nThis could allow an unauthenticated remote attacker to force the device into protection mode, which results in losing remote connectivity functions (Web Access)."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1287",
                  "description": "CWE-1287: Improper Validation of Specified Type of Input",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-16T07:59:08.075Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-823812.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-89207",
        "datePublished": "2026-09-16T07:59:08.075Z",
        "dateReserved": "2026-09-11T07:45:20.919Z",
        "dateUpdated": "2026-09-16T18:13:23.189Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-67367 (GCVE-0-2026-67367)

    Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-09 15:56
    VLAI
    Summary
    A vulnerability has been identified in SIMOVE Fleetmanager V3.1 (All versions < V3.1.13), SIMOVE Fleetmanager V3.2 (All versions < V3.2.4), SIMOVE Fleetmanager V3.3 (All versions < V3.3.2), SIMOVE Fleetmanager V4.0 (All versions < V4.0.1), SIPLANT V1.7 (All versions), SIPLANT V2.2 (All versions), SIPLANT V3.0 (All versions), SIPLANT V3.1 (All versions < V3.1.4). Affected devices do not properly validate and neutralize directory traversal sequences in the file-serving endpoint of the embedded HTTP server. This could allow an unauthenticated remote attacker to read arbitrary files from the underlying operating system without any credentials, potentially exposing sensitive data such as credential stores, private keys, and configuration secrets.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-09 15:56 UTC
    CWE
    • CWE-23 - Relative Path Traversal
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-67367",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-09T15:56:26.529587Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-09T15:56:42.377Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMOVE Fleetmanager V3.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOVE Fleetmanager V3.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.2.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOVE Fleetmanager V3.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOVE Fleetmanager V4.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLANT V1.7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLANT V2.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLANT V3.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLANT V3.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMOVE Fleetmanager V3.1 (All versions \u003c V3.1.13), SIMOVE Fleetmanager V3.2 (All versions \u003c V3.2.4), SIMOVE Fleetmanager V3.3 (All versions \u003c V3.3.2), SIMOVE Fleetmanager V4.0 (All versions \u003c V4.0.1), SIPLANT V1.7 (All versions), SIPLANT V2.2 (All versions), SIPLANT V3.0 (All versions), SIPLANT V3.1 (All versions \u003c V3.1.4). Affected devices do not properly validate and neutralize directory traversal sequences in the file-serving endpoint of the embedded HTTP server. This could allow an unauthenticated remote attacker to read arbitrary files from the underlying operating system without any credentials, potentially exposing sensitive data such as credential stores, private keys, and configuration secrets."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-23",
                  "description": "CWE-23: Relative Path Traversal",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T08:11:36.311Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-517424.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-67367",
        "datePublished": "2026-09-08T08:11:36.311Z",
        "dateReserved": "2026-07-29T14:51:27.000Z",
        "dateUpdated": "2026-09-09T15:56:42.377Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-62654 (GCVE-0-2026-62654)

    Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:24
    VLAI
    Summary
    A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). A special maintenance mode can be activated via a physical key sequence during device boot, in which the device downloads and executes program code from a network server without verifying its authenticity or integrity. This could allow an attacker with physical access to the device to upload and execute arbitrary, unsigned code.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 12:24 UTC
    CWE
    • CWE-494 - Download of Code Without Integrity Check
    Impacted products
    Vendor Product Version
    Siemens Reyrolle 7SR5 Affected: 0 , < V2.70 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-62654",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T12:24:21.127677Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T12:24:28.328Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Reyrolle 7SR5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.70",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). A special maintenance mode can be activated via a physical key sequence during device boot, in which the device downloads and executes program code from a network server without verifying its authenticity or integrity. This could allow an attacker with physical access to the device to upload and execute arbitrary, unsigned code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-494",
                  "description": "CWE-494: Download of Code Without Integrity Check",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T08:11:35.239Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-62654",
        "datePublished": "2026-09-08T08:11:35.239Z",
        "dateReserved": "2026-07-14T16:24:23.430Z",
        "dateUpdated": "2026-09-08T12:24:28.328Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-62653 (GCVE-0-2026-62653)

    Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-14 13:50
    VLAI
    Summary
    A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). The input received over a proprietary communication protocol that is exposed when the device is placed into a special firmware-update mode is not properly validated, resulting in a memory corruption condition. This could allow an unauthenticated attacker with physical access to the device to cause a crash and potentially execute arbitrary code on the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-14 13:46 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens Reyrolle 7SR5 Affected: 0 , < V2.70 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-62653",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-14T13:46:49.573069Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-14T13:50:49.465Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Reyrolle 7SR5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.70",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). The input received over a proprietary communication protocol that is exposed when the device is placed into a special firmware-update mode is not properly validated, resulting in a memory corruption condition. This could allow an unauthenticated attacker with physical access to the device to cause a crash and potentially execute arbitrary code on the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T08:11:34.180Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-62653",
        "datePublished": "2026-09-08T08:11:34.180Z",
        "dateReserved": "2026-07-14T16:24:23.430Z",
        "dateUpdated": "2026-09-14T13:50:49.465Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-62652 (GCVE-0-2026-62652)

    Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-10 18:18
    VLAI
    Summary
    A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). The device firmware contains binaries from which debugging symbols have not been removed. This could allow an unauthenticated attacker with access to the publicly available firmware update files to more easily reverse engineer the device's firmware, facilitating the identification of further vulnerabilities.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-10 18:18 UTC
    CWE
    • CWE-215 - Insertion of Sensitive Information Into Debugging Code
    Impacted products
    Vendor Product Version
    Siemens Reyrolle 7SR5 Affected: 0 , < V2.70 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-62652",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-10T18:18:16.274605Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-10T18:18:25.117Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Reyrolle 7SR5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.70",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). The device firmware contains binaries from which debugging symbols have not been removed. This could allow an unauthenticated attacker with access to the publicly available firmware update files to more easily reverse engineer the device\u0027s firmware, facilitating the identification of further vulnerabilities."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-215",
                  "description": "CWE-215: Insertion of Sensitive Information Into Debugging Code",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T08:11:33.091Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-62652",
        "datePublished": "2026-09-08T08:11:33.091Z",
        "dateReserved": "2026-07-14T16:24:23.430Z",
        "dateUpdated": "2026-09-10T18:18:25.117Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-62650 (GCVE-0-2026-62650)

    Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:24
    VLAI
    Summary
    A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). Server-side authorization checks in the web-based management interface are not properly enforced, allowing role-based access control (RBAC) restrictions to be bypassed through manipulation of request data. This could allow an authenticated, low-privileged remote attacker to escalate privileges to an administrative level.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 12:23 UTC
    CWE
    • CWE-288 - Authentication Bypass Using an Alternate Path or Channel
    Impacted products
    Vendor Product Version
    Siemens Reyrolle 7SR5 Affected: 0 , < V2.70 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-62650",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T12:23:11.725916Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T12:24:41.707Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Reyrolle 7SR5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.70",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). Server-side authorization checks in the web-based management interface are not properly enforced, allowing role-based access control (RBAC) restrictions to be bypassed through manipulation of request data. This could allow an authenticated, low-privileged remote attacker to escalate privileges to an administrative level."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-288",
                  "description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T08:11:32.013Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-62650",
        "datePublished": "2026-09-08T08:11:32.013Z",
        "dateReserved": "2026-07-14T16:24:23.430Z",
        "dateUpdated": "2026-09-08T12:24:41.707Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-62649 (GCVE-0-2026-62649)

    Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-09 15:50
    VLAI
    Summary
    A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). The web server does not properly limit or manage system resources when processing a high volume of concurrent HTTP requests. This could allow an unauthenticated remote attacker to cause the entire device to crash and reboot, resulting in a denial-of-service condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-09 15:50 UTC
    CWE
    • CWE-770 - Allocation of Resources Without Limits or Throttling
    Impacted products
    Vendor Product Version
    Siemens Reyrolle 7SR5 Affected: 0 , < V2.70 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-62649",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-09T15:50:39.262220Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-09T15:50:52.432Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Reyrolle 7SR5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.70",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). The web server does not properly limit or manage system resources when processing a high volume of concurrent HTTP requests. This could allow an unauthenticated remote attacker to cause the entire device to crash and reboot, resulting in a denial-of-service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-770",
                  "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T08:11:30.935Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-62649",
        "datePublished": "2026-09-08T08:11:30.935Z",
        "dateReserved": "2026-07-14T16:24:23.430Z",
        "dateUpdated": "2026-09-09T15:50:52.432Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-62648 (GCVE-0-2026-62648)

    Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:24
    VLAI
    Summary
    A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). The length of the URL component contained in pre-authenticated HTTP messages is not properly validated before appending additional data to it, resulting in an out-of-bounds write condition in memory. This could allow an unauthenticated remote attacker to crash the affected device, causing a reboot and resulting in a denial-of-service condition.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 12:24 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens Reyrolle 7SR5 Affected: 0 , < V2.70 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-62648",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T12:24:43.278434Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T12:24:51.786Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Reyrolle 7SR5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.70",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). The length of the URL component contained in pre-authenticated HTTP messages is not properly validated before appending additional data to it, resulting in an out-of-bounds write condition in memory. This could allow an unauthenticated remote attacker to crash the affected device, causing a reboot and resulting in a denial-of-service condition."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T08:11:29.868Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-62648",
        "datePublished": "2026-09-08T08:11:29.868Z",
        "dateReserved": "2026-07-14T16:24:23.430Z",
        "dateUpdated": "2026-09-08T12:24:51.786Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-62647 (GCVE-0-2026-62647)

    Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-14 13:50
    VLAI
    Summary
    A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). A random number generator is used to generate security-relevant values (such as session identifiers used for authentication purposes) that is not initialized with a True Random Number Generator (TRNG), resulting in a predictable sequence of generated values. This could allow an unauthenticated remote attacker to more easily predict the generated values and impersonate a legitimate authenticated user, potentially gaining unauthorized access to the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-14 13:46 UTC
    CWE
    • CWE-20 - Improper Input Validation
    Impacted products
    Vendor Product Version
    Siemens Reyrolle 7SR5 Affected: 0 , < V2.70 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-62647",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-14T13:46:37.396990Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-14T13:50:49.615Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Reyrolle 7SR5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.70",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). A random number generator is used to generate security-relevant values (such as session identifiers used for authentication purposes) that is not initialized with a True Random Number Generator (TRNG), resulting in a predictable sequence of generated values. This could allow an unauthenticated remote attacker to more easily predict the generated values and impersonate a legitimate authenticated user, potentially gaining unauthorized access to the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20: Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T08:11:24.801Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-62647",
        "datePublished": "2026-09-08T08:11:24.801Z",
        "dateReserved": "2026-07-14T16:24:23.430Z",
        "dateUpdated": "2026-09-14T13:50:49.615Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-62646 (GCVE-0-2026-62646)

    Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-10 18:19
    VLAI
    Summary
    A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). A session identifier is generated using an algorithm with insufficient randomness, resulting in a token with low entropy that can be predicted or brute-forced within a feasible number of attempts. This could allow an unauthenticated remote attacker to derive valid session identifiers and bypass authentication.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-10 18:19 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens Reyrolle 7SR5 Affected: 0 , < V2.70 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-62646",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-10T18:19:17.570941Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-10T18:19:25.743Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Reyrolle 7SR5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.70",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). A session identifier is generated using an algorithm with insufficient randomness, resulting in a token with low entropy that can be predicted or brute-forced within a feasible number of attempts. This could allow an unauthenticated remote attacker to derive valid session identifiers and bypass authentication."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-331",
                  "description": "CWE-331: Insufficient Entropy",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T08:11:23.739Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-62646",
        "datePublished": "2026-09-08T08:11:23.739Z",
        "dateReserved": "2026-07-14T16:24:23.430Z",
        "dateUpdated": "2026-09-10T18:19:25.743Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-62645 (GCVE-0-2026-62645)

    Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:26
    VLAI
    Summary
    A vulnerability has been identified in Reyrolle 7SR5 (All versions < V2.70). Information is exposed through the web interface that can be used to calculate the current and past session ID numbers. This could allow an attacker to bypass the authentication and gain unauthorized access to the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 12:26 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Impacted products
    Vendor Product Version
    Siemens Reyrolle 7SR5 Affected: 0 , < V2.70 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-62645",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T12:26:09.683968Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T12:26:29.371Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Reyrolle 7SR5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.70",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). Information is exposed through the web interface that can be used to calculate the current and past session ID numbers. This could allow an attacker to bypass the authentication and gain unauthorized access to the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T08:11:22.667Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-142885.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-62645",
        "datePublished": "2026-09-08T08:11:22.667Z",
        "dateReserved": "2026-07-14T16:24:23.429Z",
        "dateUpdated": "2026-09-08T12:26:29.371Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-58113 (GCVE-0-2026-58113)

    Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-09 15:25
    VLAI
    Summary
    A vulnerability has been identified in Teamcenter V2412 (All versions < V2412.0013), Teamcenter V2506 (All versions < V2506.0010), Teamcenter V2512 (All versions < V2512.2607), Teamcenter V2606 (All versions < V2606.2607). Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint). This could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim's Teamcenter session.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-09 15:25 UTC
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Impacted products
    Vendor Product Version
    Siemens Teamcenter V2412 Affected: 0 , < V2412.0013 (custom)
    Create a notification for this product.
    Siemens Teamcenter V2506 Affected: 0 , < V2506.0010 (custom)
    Create a notification for this product.
    Siemens Teamcenter V2512 Affected: 0 , < V2512.2607 (custom)
    Create a notification for this product.
    Siemens Teamcenter V2606 Affected: 0 , < V2606.2607 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-58113",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-09T15:25:24.743406Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-09T15:25:34.439Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2412.0013",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2506",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2506.0010",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2512",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2512.2607",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2606",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2606.2607",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Teamcenter V2412 (All versions \u003c V2412.0013), Teamcenter V2506 (All versions \u003c V2506.0010), Teamcenter V2512 (All versions \u003c V2512.2607), Teamcenter V2606 (All versions \u003c V2606.2607). Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint).\r\nThis could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim\u0027s Teamcenter session."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:N/SC:L/SI:L/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T08:11:21.609Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-157465.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-58113",
        "datePublished": "2026-09-08T08:11:21.609Z",
        "dateReserved": "2026-06-29T11:49:12.097Z",
        "dateUpdated": "2026-09-09T15:25:34.439Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50093 (GCVE-0-2026-50093)

    Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-08 12:56
    VLAI
    Summary
    A vulnerability has been identified in Siveillance Control Pro V3.0 (All versions < V3.0.12.2173), Siveillance Control Pro V4.0 (All versions < V4.0.9.2178), Siveillance Control V3.0 (All versions < V3.0.22.2177), Siveillance Control V4.0 (All versions < V4.0.11.2177). A vulnerability in the OIS web module allows an attacker to upload arbitrary files to the server. Successful exploitation of this vulnerability could allow an attacker to gain root access on the host system, potentially leading to a full compromise of the affected OIS environment.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-08 12:55 UTC
    CWE
    • CWE-434 - Unrestricted Upload of File with Dangerous Type
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50093",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T12:55:57.191112Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T12:56:05.522Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Siveillance Control Pro V3.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.12.2173",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Siveillance Control Pro V4.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.9.2178",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Siveillance Control V3.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.22.2177",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Siveillance Control V4.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.11.2177",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Siveillance Control Pro V3.0 (All versions \u003c V3.0.12.2173), Siveillance Control Pro V4.0 (All versions \u003c V4.0.9.2178), Siveillance Control V3.0 (All versions \u003c V3.0.22.2177), Siveillance Control V4.0 (All versions \u003c V4.0.11.2177). A vulnerability in the OIS web module allows an attacker to upload arbitrary files to the server. Successful exploitation of this vulnerability could allow an attacker to gain root access on the host system, potentially leading to a full compromise of the affected OIS environment."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.9,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "CWE-434: Unrestricted Upload of File with Dangerous Type",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T08:11:18.207Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-254516.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-50093",
        "datePublished": "2026-09-08T08:11:18.207Z",
        "dateReserved": "2026-06-03T14:44:36.213Z",
        "dateUpdated": "2026-09-08T12:56:05.522Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-34223 (GCVE-0-2026-34223)

    Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-14 13:50
    VLAI
    Summary
    A vulnerability has been identified in Desigo CC ClickOnce Client V6 (All versions), Desigo CC ClickOnce Client V7 (All versions), Desigo CC family V8 (All versions), Desigo CC family V9 (All versions), Desigo CC Flex Client V6 (All versions), Desigo CC Flex Client V7 (All versions), Desigo CC Installed Client V6 (All versions), Desigo CC Installed Client V7 (All versions). The affected application is vulnerable to Client Code Execution (CCE) due to insufficient input validation when handling scripts embedded within user-defined graphics documents. Specifically, when the script within a graphics document is designed or modified by an attacker to include malicious commands. When a user opens a compromised graphics document, the embedded script is executed on the client application instance, allowing an attacker to write arbitrary files to the client's operating system. Successful exploitation requires an attacker to craft a malicious graphics document and entice a user with sufficient privileges to display it. This could lead to compromise of the client operating system and potential lateral movement within the organization.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-14 13:46 UTC
    CWE
    • CWE-94 - Improper Control of Generation of Code ('Code Injection')
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-34223",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-14T13:46:27.584888Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-14T13:50:49.761Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Desigo CC ClickOnce Client V6",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo CC ClickOnce Client V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo CC family V8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo CC family V9",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo CC Flex Client V6",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo CC Flex Client V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo CC Installed Client V6",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo CC Installed Client V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Desigo CC ClickOnce Client V6 (All versions), Desigo CC ClickOnce Client V7 (All versions), Desigo CC family V8 (All versions), Desigo CC family V9 (All versions), Desigo CC Flex Client V6 (All versions), Desigo CC Flex Client V7 (All versions), Desigo CC Installed Client V6 (All versions), Desigo CC Installed Client V7 (All versions). The affected application is vulnerable to Client Code Execution (CCE) due to insufficient input validation when handling scripts embedded within user-defined graphics documents.  Specifically, when the script within a graphics document is designed or modified by an attacker to include malicious commands.  When a user opens a compromised graphics document, the embedded script is executed on the client application instance, allowing an attacker to write arbitrary files to the client\u0027s operating system. Successful exploitation requires an attacker to craft a malicious graphics document and entice a user with sufficient privileges to display it.  This could lead to compromise of the client operating system and potential lateral movement within the organization."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-94",
                  "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T08:11:17.139Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-330084.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-34223",
        "datePublished": "2026-09-08T08:11:17.139Z",
        "dateReserved": "2026-03-26T16:03:07.476Z",
        "dateUpdated": "2026-09-14T13:50:49.761Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-80465 (GCVE-0-2026-80465)

    Vulnerability from cvelistv5 – Published: 2026-09-03 11:25 – Updated: 2026-09-03 18:15
    VLAI
    Summary
    A vulnerability has been identified in Mendix SAML (Mendix 10 compatible) (All versions < V4.2.3), Mendix SAML (Mendix 11 compatible) (All versions < V4.2.3), Mendix SAML (Mendix 9.24 compatible) (All versions < V3.6.27). Affected versions of the module do not properly validate the SAML response signature. This could allow unauthenticated remote attackers to hijack an account (session) in specific SSO configurations.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-03 18:15 UTC
    CWE
    • CWE-347 - Improper Verification of Cryptographic Signature
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-80465",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-03T18:15:27.716259Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-03T18:15:38.743Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Mendix SAML (Mendix 10 compatible)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.2.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Mendix SAML (Mendix 11 compatible)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.2.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Mendix SAML (Mendix 9.24 compatible)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.6.27",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Mendix SAML (Mendix 10 compatible) (All versions \u003c V4.2.3), Mendix SAML (Mendix 11 compatible) (All versions \u003c V4.2.3), Mendix SAML (Mendix 9.24 compatible) (All versions \u003c V3.6.27). Affected versions of the module do not properly validate the SAML response signature. This could allow unauthenticated remote attackers to hijack an account (session) in specific SSO configurations."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:P/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-347",
                  "description": "CWE-347: Improper Verification of Cryptographic Signature",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-03T11:25:10.771Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-887643.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-80465",
        "datePublished": "2026-09-03T11:25:10.771Z",
        "dateReserved": "2026-08-26T12:49:28.232Z",
        "dateUpdated": "2026-09-03T18:15:38.743Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-66155 (GCVE-0-2026-66155)

    Vulnerability from cvelistv5 – Published: 2026-08-27 11:56 – Updated: 2026-08-27 14:56
    VLAI
    Summary
    A vulnerability has been identified in Element maps-ng V47 (All versions < V47.12.3), Element maps-ng V48 (All versions < V48.11.3), Element maps-ng V49 (All versions < V49.16.1). The si-map component does not properly neutralize user-controllable input of the points property that is used to render the tooltip label of map pins. This could allow an attacker to craft a malicious URL that, when loaded by a victim and the map pin is hovered over, executes arbitrary script code within the victim's browser session.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-27 14:52 UTC
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-66155",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-27T14:52:52.987225Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-27T14:56:34.021Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Element maps-ng V47",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V47.12.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Element maps-ng V48",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V48.11.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Element maps-ng V49",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V49.16.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Element maps-ng V47 (All versions \u003c V47.12.3), Element maps-ng V48 (All versions \u003c V48.11.3), Element maps-ng V49 (All versions \u003c V49.16.1). The si-map component does not properly neutralize user-controllable input of the points property that is used to render the tooltip label of map pins.\r\nThis could allow an attacker to craft a malicious URL that, when loaded by a victim and the map pin is hovered over, executes arbitrary script code within the victim\u0027s browser session."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:L/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-27T11:56:48.418Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-682041.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-66155",
        "datePublished": "2026-08-27T11:56:48.418Z",
        "dateReserved": "2026-07-24T09:01:24.331Z",
        "dateUpdated": "2026-08-27T14:56:34.021Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-69109 (GCVE-0-2026-69109)

    Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-11 18:09
    VLAI
    Summary
    A vulnerability has been identified in Siemens License Server (SLS) (All versions < V5.3). The affected application is vulnerable to a path traversal vulnerability due to lack of sanitization of user input. This could allow a remote attacker to access arbitrary files on the application.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-11 18:09 UTC
    CWE
    • CWE-35 - Path Traversal: '.../...//'
    Impacted products
    Vendor Product Version
    Siemens Siemens License Server (SLS) Affected: 0 , < V5.3 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-69109",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-11T18:09:26.390232Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T18:09:36.165Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Siemens License Server (SLS)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Siemens License Server (SLS) (All versions \u003c V5.3). The affected application is vulnerable to a path traversal vulnerability due to lack of sanitization of user input. This could allow a remote attacker to access arbitrary files on the application."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-35",
                  "description": "CWE-35: Path Traversal: \u0027.../...//\u0027",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-11T12:20:31.599Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-077553.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-69109",
        "datePublished": "2026-08-11T12:20:31.599Z",
        "dateReserved": "2026-08-03T13:13:45.768Z",
        "dateUpdated": "2026-08-11T18:09:36.165Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-69108 (GCVE-0-2026-69108)

    Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-11 14:47
    VLAI
    Summary
    A vulnerability has been identified in Siemens License Server (SLS) (All versions < V5.1). The affected application is vulnerable to a local privilege escalation due to an insecure sudoers policy. This could allow an attacker to execute arbitrary commands and plant malicious files as root, leading to full system compromise.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-11 14:47 UTC
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Impacted products
    Vendor Product Version
    Siemens Siemens License Server (SLS) Affected: 0 , < V5.1 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-69108",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-11T14:47:11.495449Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T14:47:32.332Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Siemens License Server (SLS)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Siemens License Server (SLS) (All versions \u003c V5.1). The affected application is vulnerable to a local privilege escalation due to an insecure sudoers policy. This could allow an attacker to execute arbitrary commands and plant malicious files as root, leading to full system compromise."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-11T12:20:30.526Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-077553.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-69108",
        "datePublished": "2026-08-11T12:20:30.526Z",
        "dateReserved": "2026-08-03T13:10:24.060Z",
        "dateUpdated": "2026-08-11T14:47:32.332Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-64629 (GCVE-0-2026-64629)

    Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-12 19:19
    VLAI
    Summary
    A vulnerability has been identified in Parasolid V38.0 (All versions < V38.0.235), Parasolid V38.1 (All versions < V38.1.230). The affected applications contains an out of bounds read vulnerability while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-12 17:58 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens Parasolid V38.0 Affected: 0 , < V38.0.235 (custom)
    Create a notification for this product.
    Siemens Parasolid V38.1 Affected: 0 , < V38.1.230 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-64629",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-12T17:58:57.173944Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-12T19:19:40.181Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Parasolid V38.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V38.0.235",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Parasolid V38.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V38.1.230",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Parasolid V38.0 (All versions \u003c V38.0.235), Parasolid V38.1 (All versions \u003c V38.1.230). The affected applications contains an out of bounds read vulnerability while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-11T12:20:29.453Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-138516.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-64629",
        "datePublished": "2026-08-11T12:20:29.453Z",
        "dateReserved": "2026-07-20T13:21:17.902Z",
        "dateUpdated": "2026-08-12T19:19:40.181Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-59701 (GCVE-0-2026-59701)

    Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-11 13:54
    VLAI
    Summary
    A vulnerability has been identified in Simcenter Femap (All versions < V2606.0001). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-11 13:54 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens Simcenter Femap Affected: 0 , < V2606.0001 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-59701",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-11T13:54:03.462849Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T13:54:29.547Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Femap",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2606.0001",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2606.0001). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-11T12:20:28.387Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-584312.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-59701",
        "datePublished": "2026-08-11T12:20:28.387Z",
        "dateReserved": "2026-07-06T15:11:37.370Z",
        "dateUpdated": "2026-08-11T13:54:29.547Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-59700 (GCVE-0-2026-59700)

    Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-12 19:19
    VLAI
    Summary
    A vulnerability has been identified in Simcenter Femap (All versions < V2606.0001). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-12 17:59 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens Simcenter Femap Affected: 0 , < V2606.0001 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-59700",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-12T17:59:16.034269Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-12T19:19:46.226Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Femap",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2606.0001",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2606.0001). The affected applications contains an out of bounds read vulnerability while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-11T12:20:27.310Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-584312.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-59700",
        "datePublished": "2026-08-11T12:20:27.310Z",
        "dateReserved": "2026-07-06T15:11:37.370Z",
        "dateUpdated": "2026-08-12T19:19:46.226Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-59693 (GCVE-0-2026-59693)

    Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-11 18:08
    VLAI
    Summary
    A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.233.16-7862), Desigo PXC3 (All versions < V01.21.233.16-7862), Desigo PXC4 (All versions < V02.21.194.36-2715), Desigo PXC5.E003 (All versions < V02.21.194.36-2715), Desigo PXC5.E24 (All versions < V02.21.194.36-2715), Desigo PXC7 (All versions < V02.21.194.36-2715). The affected devices are vulnerable to a denial-of-service (DoS) vulnerability. An attacker can exploit this issue by sending a malformed BACnet packet, causing the device to stop responding to BACnet queries. Recovery requires a device reset or reboot to restore normal functionality.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-11 18:08 UTC
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Impacted products
    Vendor Product Version
    Siemens Desigo DXR2 Affected: 0 , < V01.21.233.16-7862 (custom)
    Create a notification for this product.
    Siemens Desigo PXC3 Affected: 0 , < V01.21.233.16-7862 (custom)
    Create a notification for this product.
    Siemens Desigo PXC4 Affected: 0 , < V02.21.194.36-2715 (custom)
    Create a notification for this product.
    Siemens Desigo PXC5.E003 Affected: 0 , < V02.21.194.36-2715 (custom)
    Create a notification for this product.
    Siemens Desigo PXC5.E24 Affected: 0 , < V02.21.194.36-2715 (custom)
    Create a notification for this product.
    Siemens Desigo PXC7 Affected: 0 , < V02.21.194.36-2715 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-59693",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-11T18:08:48.569650Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T18:08:58.835Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Desigo DXR2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V01.21.233.16-7862",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo PXC3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V01.21.233.16-7862",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo PXC4",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V02.21.194.36-2715",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo PXC5.E003",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V02.21.194.36-2715",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo PXC5.E24",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V02.21.194.36-2715",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo PXC7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V02.21.194.36-2715",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Desigo DXR2 (All versions \u003c V01.21.233.16-7862), Desigo PXC3 (All versions \u003c V01.21.233.16-7862), Desigo PXC4 (All versions \u003c V02.21.194.36-2715), Desigo PXC5.E003 (All versions \u003c V02.21.194.36-2715), Desigo PXC5.E24 (All versions \u003c V02.21.194.36-2715), Desigo PXC7 (All versions \u003c V02.21.194.36-2715). The affected devices are vulnerable to a denial-of-service (DoS) vulnerability. An attacker can exploit this issue by sending a malformed BACnet packet, causing the device to stop responding to BACnet queries. Recovery requires a device reset or reboot to restore normal functionality."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-11T12:20:26.209Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-781903.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-59693",
        "datePublished": "2026-08-11T12:20:26.209Z",
        "dateReserved": "2026-07-06T13:50:39.917Z",
        "dateUpdated": "2026-08-11T18:08:58.835Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-59086 (GCVE-0-2026-59086)

    Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-13 09:28
    VLAI
    Summary
    A vulnerability has been identified in Simcenter Femap (All versions < V2606), Simcenter Nastran (All versions < V2606). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-11 14:49 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Impacted products
    Vendor Product Version
    Siemens Simcenter Femap Affected: 0 , < V2606 (custom)
    Create a notification for this product.
    Siemens Simcenter Nastran Affected: 0 , < V2606 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-59086",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-11T14:49:43.272762Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T14:49:55.062Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Femap",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2606",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Nastran",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2606",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2606), Simcenter Nastran (All versions \u003c V2606). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-13T09:28:24.875Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-069220.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-59086",
        "datePublished": "2026-08-11T12:20:25.108Z",
        "dateReserved": "2026-07-02T13:41:41.932Z",
        "dateUpdated": "2026-08-13T09:28:24.875Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-58115 (GCVE-0-2026-58115)

    Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-12 19:19
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4.1 running Industrial OS with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-12 17:59 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Impacted products
    Vendor Product Version
    Siemens SIMATIC IoT2050 Advanced Affected: 0 , < V4.3.4.1 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-58115",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-12T17:59:33.476267Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-12T19:19:54.001Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IoT2050 Advanced",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.3.4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions \u003c V4.3.4.1 running Industrial OS with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server.\r\nThis could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-11T12:20:24.045Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-834709.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-58115",
        "datePublished": "2026-08-11T12:20:24.045Z",
        "dateReserved": "2026-06-29T12:59:54.795Z",
        "dateUpdated": "2026-08-12T19:19:54.001Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-57263 (GCVE-0-2026-57263)

    Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-11 14:00
    VLAI
    Summary
    A vulnerability has been identified in LOGO! Soft Comfort (All versions < V9). The project password feature in the affected products stores the password as an unsalted SHA-256 hash. This could allow an attacker who has obtained the project file to perform efficient offline dictionary or brute-force attacks against the unsalted hash.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-11 13:58 UTC
    CWE
    • CWE-759 - Use of a One-Way Hash without a Salt
    Impacted products
    Vendor Product Version
    Siemens LOGO! Soft Comfort Affected: 0 , < V9 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-57263",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-11T13:58:11.222075Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T14:00:28.936Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "LOGO! Soft Comfort",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in LOGO! Soft Comfort (All versions \u003c V9). The project password feature in the affected products stores the password as an unsalted SHA-256 hash. This could allow an attacker who has obtained the project file to perform efficient offline dictionary or brute-force attacks against the unsalted hash."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-759",
                  "description": "CWE-759: Use of a One-Way Hash without a Salt",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-11T12:20:22.982Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-751328.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-57263",
        "datePublished": "2026-08-11T12:20:22.982Z",
        "dateReserved": "2026-06-24T04:43:34.162Z",
        "dateUpdated": "2026-08-11T14:00:28.936Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-57262 (GCVE-0-2026-57262)

    Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-12 19:20
    VLAI
    Summary
    A vulnerability has been identified in LOGO! Soft Comfort (All versions < V9). Affected products use a static, hardcoded AES master key to encrypt project files. This could allow a local attacker to extract the master key from the application files or memory and use it to decrypt project files or remove project passwords entirely without knowing the actual user-defined password.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-12 18:07 UTC
    CWE
    • CWE-321 - Use of Hard-coded Cryptographic Key
    Impacted products
    Vendor Product Version
    Siemens LOGO! Soft Comfort Affected: 0 , < V9 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-57262",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-12T18:07:20.598978Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-12T19:20:07.024Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "LOGO! Soft Comfort",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in LOGO! Soft Comfort (All versions \u003c V9). Affected products use a static, hardcoded AES master key to encrypt project files. This could allow a local attacker to extract the master key from the application files or memory and use it to decrypt project files or remove project passwords entirely without knowing the actual user-defined password."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "CWE-321: Use of Hard-coded Cryptographic Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-11T12:20:21.896Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-751328.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-57262",
        "datePublished": "2026-08-11T12:20:21.896Z",
        "dateReserved": "2026-06-24T04:43:34.162Z",
        "dateUpdated": "2026-08-12T19:20:07.024Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50064 (GCVE-0-2026-50064)

    Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-11 18:08
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-11 18:08 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2025 Affected: 0 , < V225.0 Update 15 (custom)
    Create a notification for this product.
    Siemens Solid Edge SE2026 Affected: 0 , < V226.0 Update 7 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50064",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-11T18:08:04.058855Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T18:08:15.586Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2025",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V225.0 Update 15",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V226.0 Update 7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2025 (All versions \u003c V225.0 Update 15), Solid Edge SE2026 (All versions \u003c V226.0 Update 7). The affected applications contains an out of bounds write vulnerability while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-11T12:20:20.783Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-621657.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-50064",
        "datePublished": "2026-08-11T12:20:20.783Z",
        "dateReserved": "2026-06-03T11:07:02.668Z",
        "dateUpdated": "2026-08-11T18:08:15.586Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50063 (GCVE-0-2026-50063)

    Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-11 14:51
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-11 14:51 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2025 Affected: 0 , < V225.0 Update 15 (custom)
    Create a notification for this product.
    Siemens Solid Edge SE2026 Affected: 0 , < V226.0 Update 7 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50063",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-11T14:51:12.839825Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T14:51:32.795Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2025",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V225.0 Update 15",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V226.0 Update 7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2025 (All versions \u003c V225.0 Update 15), Solid Edge SE2026 (All versions \u003c V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-11T12:20:19.696Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-621657.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-50063",
        "datePublished": "2026-08-11T12:20:19.696Z",
        "dateReserved": "2026-06-03T11:07:02.668Z",
        "dateUpdated": "2026-08-11T14:51:32.795Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50062 (GCVE-0-2026-50062)

    Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-12 20:55
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-12 20:52 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2025 Affected: 0 , < V225.0 Update 15 (custom)
    Create a notification for this product.
    Siemens Solid Edge SE2026 Affected: 0 , < V226.0 Update 7 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50062",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-12T20:52:45.648082Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-12T20:55:41.329Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2025",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V225.0 Update 15",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V226.0 Update 7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2025 (All versions \u003c V225.0 Update 15), Solid Edge SE2026 (All versions \u003c V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-11T12:20:18.621Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-621657.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-50062",
        "datePublished": "2026-08-11T12:20:18.621Z",
        "dateReserved": "2026-06-03T11:07:02.668Z",
        "dateUpdated": "2026-08-12T20:55:41.329Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50061 (GCVE-0-2026-50061)

    Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-11 14:00
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-11 14:00 UTC
    CWE
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2025 Affected: 0 , < V225.0 Update 15 (custom)
    Create a notification for this product.
    Siemens Solid Edge SE2026 Affected: 0 , < V226.0 Update 7 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-50061",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-11T14:00:40.251127Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T14:00:55.110Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2025",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V225.0 Update 15",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Solid Edge SE2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V226.0 Update 7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2025 (All versions \u003c V225.0 Update 15), Solid Edge SE2026 (All versions \u003c V226.0 Update 7). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-416",
                  "description": "CWE-416: Use After Free",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-11T12:20:17.413Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-621657.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-50061",
        "datePublished": "2026-08-11T12:20:17.413Z",
        "dateReserved": "2026-06-03T11:07:02.668Z",
        "dateUpdated": "2026-08-11T14:00:55.110Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }