    CVE-2026-61892 (GCVE-0-2026-61892)

    Vulnerability from nvd – Published: 2026-07-24 22:16 – Updated: 2026-07-27 14:31
    VLAI
    Title
    Weintek cMT3092X Incorrect Permission Assignment for Critical Resource
    Summary
    Weintek cMT3092X HMI allows a non-privileged user to modify tokens to escalate privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Weintek cMT3092X firmware Affected: 0 , < 20210218 (custom)
    Create a notification for this product.
    Weintek EasyWeb Affected: 0 , < v2.1.20 (custom)
    Unaffected: 2.3.17-typeb
    Create a notification for this product.
    Credits
    Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-61892",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-27T14:30:54.856897Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-27T14:31:09.468Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT3092X firmware",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EasyWeb",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "v2.1.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2.3.17-typeb"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek cMT3092X HMI allows a non-privileged user to modify tokens to escalate privileges.\u003c/span\u003e"
                }
              ],
              "value": "Weintek cMT3092X HMI allows a non-privileged user to modify tokens to escalate privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-24T22:16:58.155Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
                }
              ],
              "value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            }
          ],
          "source": {
            "advisory": "ICSA-26-204-03",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek cMT3092X Incorrect Permission Assignment for Critical Resource",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-61892",
        "datePublished": "2026-07-24T22:16:58.155Z",
        "dateReserved": "2026-07-16T16:04:55.185Z",
        "dateUpdated": "2026-07-27T14:31:09.468Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-61886 (GCVE-0-2026-61886)

    Vulnerability from nvd – Published: 2026-07-24 22:10 – Updated: 2026-07-27 14:32
    VLAI
    Title
    Weintek cMT3092X Plaintext Storage of a Password
    Summary
    Weintek cMT3092X HMI stores user account passwords in plaintext.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Weintek cMT3092X firmware Affected: 0 , < 20210218 (custom)
    Create a notification for this product.
    Weintek EasyWeb Affected: 0 , < v2.1.20 (custom)
    Unaffected: 2.3.17-typeb
    Create a notification for this product.
    Credits
    Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-61886",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-27T14:31:58.631398Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-27T14:32:07.257Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT3092X firmware",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EasyWeb",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "v2.1.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2.3.17-typeb"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek cMT3092X HMI stores user account passwords in plaintext.\u003c/span\u003e"
                }
              ],
              "value": "Weintek cMT3092X HMI stores user account passwords in plaintext."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-256",
                  "description": "CWE-256",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-24T22:10:03.065Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
                }
              ],
              "value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            }
          ],
          "source": {
            "advisory": "ICSA-26-204-03",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek cMT3092X Plaintext Storage of a Password",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-61886",
        "datePublished": "2026-07-24T22:10:03.065Z",
        "dateReserved": "2026-07-16T16:04:55.182Z",
        "dateUpdated": "2026-07-27T14:32:07.257Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-60135 (GCVE-0-2026-60135)

    Vulnerability from nvd – Published: 2026-07-24 22:06 – Updated: 2026-07-27 14:32
    VLAI
    Title
    Weintek cMT3092X Incorrect User Management
    Summary
    An attacker can modify data that should be restricted to read‑only access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Weintek cMT3092X firmware Affected: 0 , < 20210218 (custom)
    Create a notification for this product.
    Weintek EasyWeb Affected: 0 , < v2.1.20 (custom)
    Unaffected: 2.3.17-typeb
    Create a notification for this product.
    Credits
    Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-60135",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-27T14:32:24.119978Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-27T14:32:32.622Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT3092X firmware",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EasyWeb",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "v2.1.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2.3.17-typeb"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eAn attacker can modify data that should be restricted to read\u2011only access.\u003c/span\u003e"
                }
              ],
              "value": "An attacker can modify data that should be restricted to read\u2011only access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-286",
                  "description": "CWE-286",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-24T22:06:12.337Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
                }
              ],
              "value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            }
          ],
          "source": {
            "advisory": "ICSA-26-204-03",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek cMT3092X Incorrect User Management",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-60135",
        "datePublished": "2026-07-24T22:06:12.337Z",
        "dateReserved": "2026-07-16T16:04:55.177Z",
        "dateUpdated": "2026-07-27T14:32:32.622Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-60134 (GCVE-0-2026-60134)

    Vulnerability from nvd – Published: 2026-07-24 22:20 – Updated: 2026-07-27 14:30
    VLAI
    Title
    Weintek cMT3092X Reliance on Cookies without Validation and Integrity Checking in a Security Decision
    Summary
    Weintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Weintek cMT3092X firmware Affected: 0 , < 20210218 (custom)
    Create a notification for this product.
    Weintek EasyWeb Affected: 0 , < v2.1.20 (custom)
    Unaffected: 2.3.17-typeb
    Create a notification for this product.
    Credits
    Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-60134",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-27T14:30:24.338784Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-27T14:30:33.224Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT3092X firmware",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EasyWeb",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "v2.1.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2.3.17-typeb"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges.\u003c/span\u003e"
                }
              ],
              "value": "Weintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-784",
                  "description": "CWE-784",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-24T22:20:20.024Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
                }
              ],
              "value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            }
          ],
          "source": {
            "advisory": "ICSA-26-204-03",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek cMT3092X Reliance on Cookies without Validation and Integrity Checking in a Security Decision",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-60134",
        "datePublished": "2026-07-24T22:20:20.024Z",
        "dateReserved": "2026-07-16T16:04:55.188Z",
        "dateUpdated": "2026-07-27T14:30:33.224Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14751 (GCVE-0-2025-14751)

    Vulnerability from nvd – Published: 2026-01-22 21:42 – Updated: 2026-01-26 21:02
    VLAI
    Title
    Unverified Password Change in Weintek cMT X Series HMI EasyWeb Service
    Summary
    A low-privileged user can bypass account credentials without confirming the user's current authentication state, which may lead to unauthorized privilege escalation.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-620 - Unverified Password Change
    Assigner
    References
    Impacted products
    Vendor Product Version
    Weintek cMT3072XH Affected: 20200630 , < 20241112 (custom)
    Create a notification for this product.
    Weintek cMT3072XH(T) Affected: 20200630 , < 20241112 (custom)
    Create a notification for this product.
    Weintek cMT-SVRX-820 Affected: 20220413 , < 20240919 (custom)
    Create a notification for this product.
    Weintek cMT-CTRL01 Affected: 20230308 , < 20250827 (custom)
    Create a notification for this product.
    Credits
    Joel Aviad Ossi of WebSec B.V reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14751",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-26T21:01:59.502514Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-26T21:02:09.222Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT3072XH",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20241112",
                  "status": "affected",
                  "version": "20200630",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3072XH(T)",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20241112",
                  "status": "affected",
                  "version": "20200630",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT-SVRX-820",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20240919",
                  "status": "affected",
                  "version": "20220413",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT-CTRL01",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20250827",
                  "status": "affected",
                  "version": "20230308",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joel Aviad Ossi of WebSec B.V reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A low-privileged user can bypass account credentials without confirming the user\u0027s current authentication state, which may lead to unauthorized privilege escalation.\u003cbr\u003e"
                }
              ],
              "value": "A low-privileged user can bypass account credentials without confirming the user\u0027s current authentication state, which may lead to unauthorized privilege escalation."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-620",
                  "description": "CWE-620 Unverified Password Change",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-22T21:42:50.871Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Weintek recommends users implement the following mitigation techniques: \u003cbr\u003e\u003cbr\u003e* cMT3072XH: Version 20241112\u003cbr\u003e* cMT3072XH(T): Version 20241112\u003cbr\u003e* cMT-SVRX-820: Version 20240919\u003cbr\u003e* cMT-CTRL01: Version 20250827\u003cbr\u003e\u003cbr\u003eFor more information, see Weintek\u0027s planned notice: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e\u003cbr\u003e"
                }
              ],
              "value": "Weintek recommends users implement the following mitigation techniques: \n\n* cMT3072XH: Version 20241112\n* cMT3072XH(T): Version 20241112\n* cMT-SVRX-820: Version 20240919\n* cMT-CTRL01: Version 20250827\n\nFor more information, see Weintek\u0027s planned notice:  https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unverified Password Change in Weintek cMT X Series HMI EasyWeb Service",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-14751",
        "datePublished": "2026-01-22T21:42:50.871Z",
        "dateReserved": "2025-12-15T20:40:05.015Z",
        "dateUpdated": "2026-01-26T21:02:09.222Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14750 (GCVE-0-2025-14750)

    Vulnerability from nvd – Published: 2026-01-22 21:40 – Updated: 2026-01-26 21:01
    VLAI
    Title
    External Control of Assumed-Immutable Web Parameter in Weintek cMT X Series HMI EasyWeb Service
    Summary
    The web application does not sufficiently verify inputs that are assumed to be immutable but are actually externally controllable. A low-privileged user can modify the parameters and potentially manipulate account-level privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-472 - External Control of Assumed-Immutable Web Parameter
    Assigner
    References
    Impacted products
    Vendor Product Version
    Weintek cMT3072XH Affected: 20200630 , < 20241112 (custom)
    Create a notification for this product.
    Weintek cMT3072XH(T) Affected: 20200630 , < 20241112 (custom)
    Create a notification for this product.
    Weintek cMT-SVRX-820 Affected: 20220413 , < 20240919 (custom)
    Create a notification for this product.
    Weintek cMT-CTRL01 Affected: 20230308 , < 20250827 (custom)
    Create a notification for this product.
    Credits
    Joel Aviad Ossi of WebSec B.V reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14750",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-26T21:01:22.166872Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-26T21:01:31.626Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT3072XH",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20241112",
                  "status": "affected",
                  "version": "20200630",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3072XH(T)",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20241112",
                  "status": "affected",
                  "version": "20200630",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT-SVRX-820",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20240919",
                  "status": "affected",
                  "version": "20220413",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT-CTRL01",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20250827",
                  "status": "affected",
                  "version": "20230308",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joel Aviad Ossi of WebSec B.V reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The web application does not sufficiently verify inputs that are assumed to be immutable but are actually externally controllable. A low-privileged user can modify the parameters and potentially manipulate account-level privileges. \u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The web application does not sufficiently verify inputs that are assumed to be immutable but are actually externally controllable. A low-privileged user can modify the parameters and potentially manipulate account-level privileges."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-472",
                  "description": "CWE-472 External Control of Assumed-Immutable Web Parameter",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-22T21:40:56.977Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Weintek recommends users implement the following mitigation techniques: \u003cbr\u003e\u003cbr\u003e* cMT3072XH: Version 20241112\u003cbr\u003e* cMT3072XH(T): Version 20241112\u003cbr\u003e* cMT-SVRX-820: Version 20240919\u003cbr\u003e* cMT-CTRL01: Version 20250827\u003cbr\u003e\u003cbr\u003eFor more information, see Weintek\u0027s planned notice: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e\u003cbr\u003e"
                }
              ],
              "value": "Weintek recommends users implement the following mitigation techniques: \n\n* cMT3072XH: Version 20241112\n* cMT3072XH(T): Version 20241112\n* cMT-SVRX-820: Version 20240919\n* cMT-CTRL01: Version 20250827\n\nFor more information, see Weintek\u0027s planned notice:  https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "External Control of Assumed-Immutable Web Parameter in Weintek cMT X Series HMI EasyWeb Service",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-14750",
        "datePublished": "2026-01-22T21:40:56.977Z",
        "dateReserved": "2025-12-15T20:40:03.048Z",
        "dateUpdated": "2026-01-26T21:01:31.626Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2023-5777 (GCVE-0-2023-5777)

    Vulnerability from nvd – Published: 2023-11-06 19:26 – Updated: 2025-01-16 21:26
    VLAI
    Title
    Weintek EasyBuilder Pro Use of Hard-coded Credentials
    Summary
    Weintek EasyBuilder Pro contains a vulnerability that, even when the private key is immediately deleted after the crash report transmission is finished, the private key is exposed to the public, which could result in obtaining remote control of the crash report server.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    Impacted products
    Vendor Product Version
    Weintek EasyBuilder Pro Affected: 0 , < v6.07.02 (custom)
    Affected: 0 , ≤ 6.08.01.592 (custom)
    Affected: 0 , ≤ 6.08.02.470 (custom)
    Create a notification for this product.
    Date Public
    2023-11-02 17:00
    Credits
    Hank Chen (PSIRT and Threat Research of TXOne Networks) reported this vulnerability to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T08:07:32.769Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-306-05"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-5777",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-16T21:22:21.675124Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-16T21:26:49.870Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyBuilder Pro",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "v6.07.02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.08.01.592",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.08.02.470",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Hank Chen (PSIRT and Threat Research of TXOne Networks) reported this vulnerability to CISA."
            }
          ],
          "datePublic": "2023-11-02T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWeintek EasyBuilder Pro contains a vulnerability that, even when the private key is immediately deleted after the crash report transmission is finished, the private key is exposed to the public, which could result in obtaining remote control of the crash report server.\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\n\n\nWeintek EasyBuilder Pro contains a vulnerability that, even when the private key is immediately deleted after the crash report transmission is finished, the private key is exposed to the public, which could result in obtaining remote control of the crash report server.\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-06T19:26:09.044Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-306-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eWeintek recommends users apply the following mitigations:\u003c/p\u003e\u003cul\u003e\u003cli\u003eUpdate EasyBuilder Pro to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.weintek.com/globalw/Download/Download.aspx\"\u003ev6.08.01.614\u003c/a\u003e\u003c/li\u003e\u003cli\u003eUpdate EasyBuilder Pro to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.weintek.com/globalw/Download/Download.aspx\"\u003ev6.08.02.500\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n\n\n\n\nWeintek recommends users apply the following mitigations:\n\n  *  Update EasyBuilder Pro to  v6.08.01.614 https://www.weintek.com/globalw/Download/Download.aspx \n  *  Update EasyBuilder Pro to  v6.08.02.500 https://www.weintek.com/globalw/Download/Download.aspx \n\n\n\n\n\n\n\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSA-23-306-05",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek EasyBuilder Pro Use of Hard-coded Credentials",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-5777",
        "datePublished": "2023-11-06T19:26:09.044Z",
        "dateReserved": "2023-10-25T22:32:36.999Z",
        "dateUpdated": "2025-01-16T21:26:49.870Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-43492 (GCVE-0-2023-43492)

    Vulnerability from nvd – Published: 2023-10-19 19:28 – Updated: 2025-01-16 21:28
    VLAI
    Title
    Weintek cMT3000 HMI Web CGI Stack-based Buffer Overflow
    Summary
    In Weintek's cMT3000 HMI Web CGI device, the cgi-bin codesys.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Impacted products
    Vendor Product Version
    Weintek cMT-FHD Affected: 0 , ≤ 20210210 (custom)
    Create a notification for this product.
    Weintek cMT-HDM Affected: 0 , ≤ 20210204 (custom)
    Create a notification for this product.
    Weintek cMT3071 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3072 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3103 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3090 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3151 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Date Public
    2023-10-12 17:00
    Credits
    Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T19:44:43.206Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-12"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-43492",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-16T21:22:40.211272Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-16T21:28:29.900Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT-FHD",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210210 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT-HDM",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210204 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3071",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3072",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3103",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3090",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3151",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-10-12T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIn Weintek\u0027s cMT3000 HMI Web CGI device, the cgi-bin codesys.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e"
                }
              ],
              "value": "\n\n\n\n\n\n\n\n\nIn Weintek\u0027s cMT3000 HMI Web CGI device, the cgi-bin codesys.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-19T19:28:59.236Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-12"
            },
            {
              "url": "https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\n\n\u003cp\u003eWeintek recommends users follow their \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/UM0/UM018010E_cMT_Series_OS_Update_Instructions_eng.pdf\"\u003eUpgrade Instructions\u003c/a\u003e\u0026nbsp;to update the following products to the latest versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003ecMT-FHD: OS version 20210211\u003c/li\u003e\u003cli\u003ecMT-HDM: OS version 20210205\u003c/li\u003e\u003cli\u003ecMT3071: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3072: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3103: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3090: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3151: OS version 20210219\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor additional information, refer to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf\"\u003eWeintek\u0027s security bulletin\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n\n\n\n\nWeintek recommends users follow their  Upgrade Instructions https://dl.weintek.com/public/Document/UM0/UM018010E_cMT_Series_OS_Update_Instructions_eng.pdf \u00a0to update the following products to the latest versions:\n\n  *  cMT-FHD: OS version 20210211\n  *  cMT-HDM: OS version 20210205\n  *  cMT3071: OS version 20210219\n  *  cMT3072: OS version 20210219\n  *  cMT3103: OS version 20210219\n  *  cMT3090: OS version 20210219\n  *  cMT3151: OS version 20210219\n\n\nFor additional information, refer to  Weintek\u0027s security bulletin https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf .\n\n\n\n\n\n\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSMA-23-285-12",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek cMT3000 HMI Web CGI Stack-based Buffer Overflow",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-43492",
        "datePublished": "2023-10-19T19:28:59.236Z",
        "dateReserved": "2023-09-20T14:26:47.014Z",
        "dateUpdated": "2025-01-16T21:28:29.900Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-40145 (GCVE-0-2023-40145)

    Vulnerability from nvd – Published: 2023-10-19 19:26 – Updated: 2025-01-16 21:28
    VLAI
    Title
    Weintek cMT3000 HMI Web CGI OS Command Injection
    Summary
    In Weintek's cMT3000 HMI Web CGI device, an anonymous attacker can execute arbitrary commands after login to the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - OS Command Injection
    Assigner
    Impacted products
    Vendor Product Version
    Weintek cMT-FHD Affected: 0 , ≤ 20210210 (custom)
    Create a notification for this product.
    Weintek cMT-HDM Affected: 0 , ≤ 20210204 (custom)
    Create a notification for this product.
    Weintek cMT3071 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3072 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3103 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3090 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3151 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Date Public
    2023-10-12 17:00
    Credits
    Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T18:24:55.542Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-12"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-40145",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-16T21:20:09.729366Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-16T21:28:39.035Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT-FHD",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210210 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT-HDM",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210204 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3071",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3072",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3103",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3090",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3151",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-10-12T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIn Weintek\u0027s cMT3000 HMI Web CGI device, an anonymous attacker can execute arbitrary commands after login to the device.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e"
                }
              ],
              "value": "\n\n\n\n\n\n\n\n\nIn Weintek\u0027s cMT3000 HMI Web CGI device, an anonymous attacker can execute arbitrary commands after login to the device.\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-19T19:26:20.948Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-12"
            },
            {
              "url": "https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\n\n\u003cp\u003eWeintek recommends users follow their \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/UM0/UM018010E_cMT_Series_OS_Update_Instructions_eng.pdf\"\u003eUpgrade Instructions\u003c/a\u003e\u0026nbsp;to update the following products to the latest versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003ecMT-FHD: OS version 20210211\u003c/li\u003e\u003cli\u003ecMT-HDM: OS version 20210205\u003c/li\u003e\u003cli\u003ecMT3071: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3072: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3103: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3090: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3151: OS version 20210219\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor additional information, refer to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf\"\u003eWeintek\u0027s security bulletin\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n\n\n\n\nWeintek recommends users follow their  Upgrade Instructions https://dl.weintek.com/public/Document/UM0/UM018010E_cMT_Series_OS_Update_Instructions_eng.pdf \u00a0to update the following products to the latest versions:\n\n  *  cMT-FHD: OS version 20210211\n  *  cMT-HDM: OS version 20210205\n  *  cMT3071: OS version 20210219\n  *  cMT3072: OS version 20210219\n  *  cMT3103: OS version 20210219\n  *  cMT3090: OS version 20210219\n  *  cMT3151: OS version 20210219\n\n\nFor additional information, refer to  Weintek\u0027s security bulletin https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf .\n\n\n\n\n\n\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSMA-23-285-12",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek cMT3000 HMI Web CGI OS Command Injection",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-40145",
        "datePublished": "2023-10-19T19:26:20.948Z",
        "dateReserved": "2023-09-20T14:26:47.028Z",
        "dateUpdated": "2025-01-16T21:28:39.035Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-38584 (GCVE-0-2023-38584)

    Vulnerability from nvd – Published: 2023-10-19 19:20 – Updated: 2025-01-16 21:28
    VLAI
    Title
    Weintek cMT3000 HMI Web CGI Stack-based Buffer Overflow
    Summary
    In Weintek's cMT3000 HMI Web CGI device, the cgi-bin command_wb.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Impacted products
    Vendor Product Version
    Weintek cMT-FHD Affected: 0 , ≤ 20210210 (custom)
    Create a notification for this product.
    Weintek cMT-HDM Affected: 0 , ≤ 20210204 (custom)
    Create a notification for this product.
    Weintek cMT3071 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3072 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3103 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3090 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3151 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Date Public
    2023-10-12 17:00
    Credits
    Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:46:56.458Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-12"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-38584",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-16T21:22:44.800664Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-16T21:28:46.086Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT-FHD",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210210 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT-HDM",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210204 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3071",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3072",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3103",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3090",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3151",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-10-12T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIn Weintek\u0027s cMT3000 HMI Web CGI device, the cgi-bin command_wb.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.\u003c/span\u003e\n\n\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e"
                }
              ],
              "value": "\n\n\n\n\n\n\nIn Weintek\u0027s cMT3000 HMI Web CGI device, the cgi-bin command_wb.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-19T19:20:20.059Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-12"
            },
            {
              "url": "https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\n\n\u003cp\u003eWeintek recommends users follow their \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/UM0/UM018010E_cMT_Series_OS_Update_Instructions_eng.pdf\"\u003eUpgrade Instructions\u003c/a\u003e\u0026nbsp;to update the following products to the latest versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003ecMT-FHD: OS version 20210211\u003c/li\u003e\u003cli\u003ecMT-HDM: OS version 20210205\u003c/li\u003e\u003cli\u003ecMT3071: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3072: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3103: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3090: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3151: OS version 20210219\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor additional information, refer to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf\"\u003eWeintek\u0027s security bulletin\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n\n\n\n\nWeintek recommends users follow their  Upgrade Instructions https://dl.weintek.com/public/Document/UM0/UM018010E_cMT_Series_OS_Update_Instructions_eng.pdf \u00a0to update the following products to the latest versions:\n\n  *  cMT-FHD: OS version 20210211\n  *  cMT-HDM: OS version 20210205\n  *  cMT3071: OS version 20210219\n  *  cMT3072: OS version 20210219\n  *  cMT3103: OS version 20210219\n  *  cMT3090: OS version 20210219\n  *  cMT3151: OS version 20210219\n\n\nFor additional information, refer to  Weintek\u0027s security bulletin https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf .\n\n\n\n\n\n\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSMA-23-285-12",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek cMT3000 HMI Web CGI Stack-based Buffer Overflow",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-38584",
        "datePublished": "2023-10-19T19:20:20.059Z",
        "dateReserved": "2023-09-20T14:26:47.021Z",
        "dateUpdated": "2025-01-16T21:28:46.086Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-37362 (GCVE-0-2023-37362)

    Vulnerability from nvd – Published: 2023-07-19 21:50 – Updated: 2025-03-06 15:04
    VLAI
    Title
    Weintek Weincloud Improper Authentication
    Summary
    Weintek Weincloud v0.13.6 could allow an attacker to abuse the registration functionality to login with testing credentials to the official website.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-522 - Insufficiently Protected Credentials
    Assigner
    Impacted products
    Vendor Product Version
    Weintek Weincloud Affected: 0 , ≤ 0.13.6 (custom)
    Create a notification for this product.
    Date Public
    2023-07-18 17:00
    Credits
    ​Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:09:34.107Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-37362",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-28T14:20:12.749745Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-28T14:20:20.599Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Weincloud",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "0.13.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "\u200bHank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-07-18T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWeintek Weincloud v\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e0.13.6\u003c/span\u003e\n\n \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ecould allow an attacker to abuse the registration functionality to login with testing credentials to the official website.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Weintek Weincloud v0.13.6\n\n \n\ncould allow an attacker to abuse the registration functionality to login with testing credentials to the official website."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-522",
                  "description": "CWE-522 Insufficiently Protected Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-06T15:04:53.644Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users.\u003c/p\u003e\u003cp\u003e\u003cbr\u003e\u003c/p\u003e"
                }
              ],
              "value": "\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users."
            }
          ],
          "source": {
            "advisory": "ICSA-23-199-04",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek Weincloud Improper Authentication",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\u200bAdditional mitigations are recommended to help reduce risk:\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\u003c/li\u003e\u003cli\u003e\u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\u003c/li\u003e\u003cli\u003e\u200bRegularly change passwords to reduce risks.\u003c/li\u003e\u003cli\u003e\u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\u200bAdditional mitigations are recommended to help reduce risk:\n\n  *  \u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\n  *  \u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\n  *  \u200bRegularly change passwords to reduce risks.\n  *  \u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-37362",
        "datePublished": "2023-07-19T21:50:42.036Z",
        "dateReserved": "2023-07-13T15:55:48.885Z",
        "dateUpdated": "2025-03-06T15:04:53.644Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-35134 (GCVE-0-2023-35134)

    Vulnerability from nvd – Published: 2023-07-19 21:43 – Updated: 2024-10-28 14:30
    VLAI
    Title
    Weintek Weincloud Weak Password Recovery Mechanism for Forgotten Password
    Summary
    Weintek Weincloud v0.13.6 could allow an attacker to reset a password with the corresponding account’s JWT token only.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-640 - Weak Password Recovery Mechanism for Forgotten Password
    Assigner
    Impacted products
    Vendor Product Version
    Weintek Weincloud Affected: 0 , ≤ 0.13.6 (custom)
    Create a notification for this product.
    Date Public
    2023-07-18 17:00
    Credits
    ​Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:23:59.280Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-35134",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-28T14:29:57.942492Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-28T14:30:07.804Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Weincloud",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "0.13.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "\u200bHank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-07-18T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWeintek Weincloud v\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e0.13.6\u003c/span\u003e\n\n could allow an attacker to reset a password with the corresponding account\u2019s JWT token only.\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\n\n\nWeintek Weincloud v0.13.6\n\n could allow an attacker to reset a password with the corresponding account\u2019s JWT token only.\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-640",
                  "description": "CWE-640 Weak Password Recovery Mechanism for Forgotten Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-19T21:43:20.562Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users.\u003c/p\u003e\u003cp\u003e\u003cbr\u003e\u003c/p\u003e"
                }
              ],
              "value": "\n\n\n\n\n\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users.\n\n\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSA-23-199-04",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek Weincloud Weak Password Recovery Mechanism for Forgotten Password",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003e\u200bAdditional mitigations are recommended to help reduce risk:\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\u003c/li\u003e\u003cli\u003e\u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\u003c/li\u003e\u003cli\u003e\u200bRegularly change passwords to reduce risks.\u003c/li\u003e\u003cli\u003e\u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n\u200bAdditional mitigations are recommended to help reduce risk:\n\n  *  \u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\n  *  \u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\n  *  \u200bRegularly change passwords to reduce risks.\n  *  \u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet.\n\n\n\n\n\n"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-35134",
        "datePublished": "2023-07-19T21:43:20.562Z",
        "dateReserved": "2023-07-13T15:55:48.879Z",
        "dateUpdated": "2024-10-28T14:30:07.804Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-34429 (GCVE-0-2023-34429)

    Vulnerability from nvd – Published: 2023-07-19 21:45 – Updated: 2024-10-28 14:29
    VLAI
    Title
    Weintek Weincloud Improper Handling of Structural Elements
    Summary
    Weintek Weincloud v0.13.6 could allow an attacker to cause a denial-of-service condition for Weincloud by sending a forged JWT token.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-237 - Improper Handling of Structural Elements
    Assigner
    Impacted products
    Vendor Product Version
    Weintek Weincloud Affected: 0 , ≤ 0.13.6 (custom)
    Create a notification for this product.
    Date Public
    2023-07-18 17:00
    Credits
    ​Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:10:07.023Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-34429",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-28T14:29:27.447079Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-28T14:29:40.049Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Weincloud",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "0.13.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "\u200bHank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-07-18T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWeintek Weincloud v\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e0.13.6\u003c/span\u003e\n\n \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ecould \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eallow an attacker to cause a denial-of-service condition for Weincloud by sending a forged JWT token.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\n\n\nWeintek Weincloud v0.13.6\n\n \n\ncould allow an attacker to cause a denial-of-service condition for Weincloud by sending a forged JWT token.\n\n\n\n\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-237",
                  "description": "CWE-237 Improper Handling of Structural Elements",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-19T21:45:39.544Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users.\u003c/p\u003e\u003cp\u003e\u200b\u003c/p\u003e"
                }
              ],
              "value": "\n\n\n\n\n\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users.\n\n\u200b\n\n"
            }
          ],
          "source": {
            "advisory": "ICSA-23-199-04",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek Weincloud Improper Handling of Structural Elements",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003eAdditional mitigations are recommended to help reduce risk:\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\u003c/li\u003e\u003cli\u003e\u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\u003c/li\u003e\u003cli\u003e\u200bRegularly change passwords to reduce risks.\u003c/li\u003e\u003cli\u003e\u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nAdditional mitigations are recommended to help reduce risk:\n\n  *  \u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\n  *  \u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\n  *  \u200bRegularly change passwords to reduce risks.\n  *  \u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet.\n\n\n\n\n\n"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-34429",
        "datePublished": "2023-07-19T21:45:39.544Z",
        "dateReserved": "2023-07-13T15:55:48.894Z",
        "dateUpdated": "2024-10-28T14:29:40.049Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-32657 (GCVE-0-2023-32657)

    Vulnerability from nvd – Published: 2023-07-19 21:47 – Updated: 2024-10-28 14:20
    VLAI
    Title
    Weintek Weincloud Improper Restriction of Excessive Authentication Attempts
    Summary
    Weintek Weincloud v0.13.6 could allow an attacker to efficiently develop a brute force attack on credentials with authentication hints from error message responses.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-307 - Improper Restriction of Excessive Authentication Attempts
    Assigner
    Impacted products
    Vendor Product Version
    Weintek Weincloud Affected: 0 , ≤ 0.13.6 (custom)
    Create a notification for this product.
    Date Public
    2023-07-18 17:00
    Credits
    ​Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:25:36.554Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-32657",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-28T14:20:43.540823Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-28T14:20:52.959Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Weincloud",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "0.13.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "\u200bHank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-07-18T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWeintek Weincloud v\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e0.13.6\u003c/span\u003e\n\n \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ecould \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eallow an attacker to efficiently develop a brute force attack on credentials with authentication hints from error message responses.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\n\n\nWeintek Weincloud v0.13.6\n\n \n\ncould allow an attacker to efficiently develop a brute force attack on credentials with authentication hints from error message responses.\n\n\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-307",
                  "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-19T21:47:37.160Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users.\u003c/p\u003e\u003cp\u003e\u003cbr\u003e\u003c/p\u003e"
                }
              ],
              "value": "\n\n\n\n\n\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users.\n\n\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSA-23-199-04",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek Weincloud Improper Restriction of Excessive Authentication Attempts",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003e\u200bAdditional mitigations are recommended to help reduce risk:\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\u003c/li\u003e\u003cli\u003e\u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\u003c/li\u003e\u003cli\u003e\u200bRegularly change passwords to reduce risks.\u003c/li\u003e\u003cli\u003e\u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n\u200bAdditional mitigations are recommended to help reduce risk:\n\n  *  \u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\n  *  \u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\n  *  \u200bRegularly change passwords to reduce risks.\n  *  \u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet.\n\n\n\n\n\n"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-32657",
        "datePublished": "2023-07-19T21:47:37.160Z",
        "dateReserved": "2023-07-13T15:55:48.890Z",
        "dateUpdated": "2024-10-28T14:20:52.959Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-0104 (GCVE-0-2023-0104)

    Vulnerability from nvd – Published: 2023-02-22 20:25 – Updated: 2025-01-16 21:55
    VLAI
    Summary
    The listed versions for Weintek EasyBuilder Pro are vulnerable to a ZipSlip attack caused by decompiling a malicious project file. This may allow an attacker to gain control of the user’s computer or gain access to sensitive data.  
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-29 - Path Traversal: '\..\filename'
    Assigner
    Impacted products
    Vendor Product Version
    Weintek EasyBuilder Pro cMT Affected: 0 , ≤ 6.07.01 (custom)
    Affected: 0 , ≤ 6.07.02.479 (custom)
    Affected: 0 , ≤ 6.08.01.349 (custom)
    Create a notification for this product.
    Credits
    Hank Chen and Mars Cheng of PSIRT and Threat Research of TXOne Networks reported this vulnerability to CISA. Patrick Kuo of TXOne Networks also contributed to this research.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:02:43.504Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-045-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-0104",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-16T20:21:56.130362Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-16T21:55:59.469Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyBuilder Pro cMT ",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "6.07.01",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.07.02.479 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.08.01.349 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Hank Chen and Mars Cheng of PSIRT and Threat Research of TXOne Networks reported this vulnerability to CISA. Patrick Kuo of TXOne Networks also contributed to this research."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003eThe listed versions for Weintek EasyBuilder Pro are vulnerable to a ZipSlip attack caused by decompiling a malicious project file. This may allow an attacker to gain control of the user\u2019s computer or gain access to sensitive data. \u0026nbsp; \u003c/p\u003e\u003cbr\u003e\n\n"
                }
              ],
              "value": "\nThe listed versions for Weintek EasyBuilder Pro are vulnerable to a ZipSlip attack caused by decompiling a malicious project file. This may allow an attacker to gain control of the user\u2019s computer or gain access to sensitive data. \u00a0 \n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-29",
                  "description": "CWE-29 Path Traversal: \u0027\\..\\filename\u0027",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-22T20:25:04.680Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-045-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: var(--wht);\"\u003eWeintek recommends users to implement the following\nmitigation techniques:\u003c/span\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nUpgrade EasyBuilder Pro to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/EBPro/Installer/EBproV60702480.zip\"\u003ev6.07.02.480\u003c/a\u003e,\n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/EBPro/Installer/EBproV60801350.zip\"\u003ev6.08.01.350\u003c/a\u003e\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nUse Decompile only on trusted sources and only when\nneeded.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
                }
              ],
              "value": "Weintek recommends users to implement the following\nmitigation techniques:\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nUpgrade EasyBuilder Pro to  v6.07.02.480 https://dl.weintek.com/EBPro/Installer/EBproV60702480.zip ,\n v6.08.01.350 https://dl.weintek.com/EBPro/Installer/EBproV60801350.zip \nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nUse Decompile only on trusted sources and only when\nneeded.\n\n\n\n\n\n\n\n\n"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-0104",
        "datePublished": "2023-02-22T20:25:04.680Z",
        "dateReserved": "2023-01-06T18:50:05.156Z",
        "dateUpdated": "2025-01-16T21:55:59.469Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-60134 (GCVE-0-2026-60134)

    Vulnerability from cvelistv5 – Published: 2026-07-24 22:20 – Updated: 2026-07-27 14:30
    VLAI
    Title
    Weintek cMT3092X Reliance on Cookies without Validation and Integrity Checking in a Security Decision
    Summary
    Weintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Weintek cMT3092X firmware Affected: 0 , < 20210218 (custom)
    Create a notification for this product.
    Weintek EasyWeb Affected: 0 , < v2.1.20 (custom)
    Unaffected: 2.3.17-typeb
    Create a notification for this product.
    Credits
    Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-60134",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-27T14:30:24.338784Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-27T14:30:33.224Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT3092X firmware",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EasyWeb",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "v2.1.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2.3.17-typeb"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges.\u003c/span\u003e"
                }
              ],
              "value": "Weintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-784",
                  "description": "CWE-784",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-24T22:20:20.024Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
                }
              ],
              "value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            }
          ],
          "source": {
            "advisory": "ICSA-26-204-03",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek cMT3092X Reliance on Cookies without Validation and Integrity Checking in a Security Decision",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-60134",
        "datePublished": "2026-07-24T22:20:20.024Z",
        "dateReserved": "2026-07-16T16:04:55.188Z",
        "dateUpdated": "2026-07-27T14:30:33.224Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-61892 (GCVE-0-2026-61892)

    Vulnerability from cvelistv5 – Published: 2026-07-24 22:16 – Updated: 2026-07-27 14:31
    VLAI
    Title
    Weintek cMT3092X Incorrect Permission Assignment for Critical Resource
    Summary
    Weintek cMT3092X HMI allows a non-privileged user to modify tokens to escalate privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Weintek cMT3092X firmware Affected: 0 , < 20210218 (custom)
    Create a notification for this product.
    Weintek EasyWeb Affected: 0 , < v2.1.20 (custom)
    Unaffected: 2.3.17-typeb
    Create a notification for this product.
    Credits
    Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-61892",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-27T14:30:54.856897Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-27T14:31:09.468Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT3092X firmware",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EasyWeb",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "v2.1.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2.3.17-typeb"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek cMT3092X HMI allows a non-privileged user to modify tokens to escalate privileges.\u003c/span\u003e"
                }
              ],
              "value": "Weintek cMT3092X HMI allows a non-privileged user to modify tokens to escalate privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-24T22:16:58.155Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
                }
              ],
              "value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            }
          ],
          "source": {
            "advisory": "ICSA-26-204-03",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek cMT3092X Incorrect Permission Assignment for Critical Resource",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-61892",
        "datePublished": "2026-07-24T22:16:58.155Z",
        "dateReserved": "2026-07-16T16:04:55.185Z",
        "dateUpdated": "2026-07-27T14:31:09.468Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-61886 (GCVE-0-2026-61886)

    Vulnerability from cvelistv5 – Published: 2026-07-24 22:10 – Updated: 2026-07-27 14:32
    VLAI
    Title
    Weintek cMT3092X Plaintext Storage of a Password
    Summary
    Weintek cMT3092X HMI stores user account passwords in plaintext.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Weintek cMT3092X firmware Affected: 0 , < 20210218 (custom)
    Create a notification for this product.
    Weintek EasyWeb Affected: 0 , < v2.1.20 (custom)
    Unaffected: 2.3.17-typeb
    Create a notification for this product.
    Credits
    Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-61886",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-27T14:31:58.631398Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-27T14:32:07.257Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT3092X firmware",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EasyWeb",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "v2.1.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2.3.17-typeb"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek cMT3092X HMI stores user account passwords in plaintext.\u003c/span\u003e"
                }
              ],
              "value": "Weintek cMT3092X HMI stores user account passwords in plaintext."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-256",
                  "description": "CWE-256",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-24T22:10:03.065Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
                }
              ],
              "value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            }
          ],
          "source": {
            "advisory": "ICSA-26-204-03",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek cMT3092X Plaintext Storage of a Password",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-61886",
        "datePublished": "2026-07-24T22:10:03.065Z",
        "dateReserved": "2026-07-16T16:04:55.182Z",
        "dateUpdated": "2026-07-27T14:32:07.257Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-60135 (GCVE-0-2026-60135)

    Vulnerability from cvelistv5 – Published: 2026-07-24 22:06 – Updated: 2026-07-27 14:32
    VLAI
    Title
    Weintek cMT3092X Incorrect User Management
    Summary
    An attacker can modify data that should be restricted to read‑only access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Weintek cMT3092X firmware Affected: 0 , < 20210218 (custom)
    Create a notification for this product.
    Weintek EasyWeb Affected: 0 , < v2.1.20 (custom)
    Unaffected: 2.3.17-typeb
    Create a notification for this product.
    Credits
    Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-60135",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-07-27T14:32:24.119978Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-07-27T14:32:32.622Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT3092X firmware",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EasyWeb",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "v2.1.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "2.3.17-typeb"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eAn attacker can modify data that should be restricted to read\u2011only access.\u003c/span\u003e"
                }
              ],
              "value": "An attacker can modify data that should be restricted to read\u2011only access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-286",
                  "description": "CWE-286",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-24T22:06:12.337Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (\u003c/span\u003e\u003ca href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\"\u003ehttps://www.weintek.com/globalw/Support/Knowledge.aspx\u003c/a\u003e\u003cspan\u003e) or from distributors.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors."
            },
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eWeintek has published a document with more details about this issue at:\u0026nbsp;\u003c/span\u003e\u003cbr\u003e\u003ca href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e"
                }
              ],
              "value": "Weintek has published a document with more details about this issue at:\u00a0\n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            }
          ],
          "source": {
            "advisory": "ICSA-26-204-03",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek cMT3092X Incorrect User Management",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-60135",
        "datePublished": "2026-07-24T22:06:12.337Z",
        "dateReserved": "2026-07-16T16:04:55.177Z",
        "dateUpdated": "2026-07-27T14:32:32.622Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14751 (GCVE-0-2025-14751)

    Vulnerability from cvelistv5 – Published: 2026-01-22 21:42 – Updated: 2026-01-26 21:02
    VLAI
    Title
    Unverified Password Change in Weintek cMT X Series HMI EasyWeb Service
    Summary
    A low-privileged user can bypass account credentials without confirming the user's current authentication state, which may lead to unauthorized privilege escalation.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-620 - Unverified Password Change
    Assigner
    References
    Impacted products
    Vendor Product Version
    Weintek cMT3072XH Affected: 20200630 , < 20241112 (custom)
    Create a notification for this product.
    Weintek cMT3072XH(T) Affected: 20200630 , < 20241112 (custom)
    Create a notification for this product.
    Weintek cMT-SVRX-820 Affected: 20220413 , < 20240919 (custom)
    Create a notification for this product.
    Weintek cMT-CTRL01 Affected: 20230308 , < 20250827 (custom)
    Create a notification for this product.
    Credits
    Joel Aviad Ossi of WebSec B.V reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14751",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-26T21:01:59.502514Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-26T21:02:09.222Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT3072XH",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20241112",
                  "status": "affected",
                  "version": "20200630",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3072XH(T)",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20241112",
                  "status": "affected",
                  "version": "20200630",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT-SVRX-820",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20240919",
                  "status": "affected",
                  "version": "20220413",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT-CTRL01",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20250827",
                  "status": "affected",
                  "version": "20230308",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joel Aviad Ossi of WebSec B.V reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A low-privileged user can bypass account credentials without confirming the user\u0027s current authentication state, which may lead to unauthorized privilege escalation.\u003cbr\u003e"
                }
              ],
              "value": "A low-privileged user can bypass account credentials without confirming the user\u0027s current authentication state, which may lead to unauthorized privilege escalation."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-620",
                  "description": "CWE-620 Unverified Password Change",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-22T21:42:50.871Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Weintek recommends users implement the following mitigation techniques: \u003cbr\u003e\u003cbr\u003e* cMT3072XH: Version 20241112\u003cbr\u003e* cMT3072XH(T): Version 20241112\u003cbr\u003e* cMT-SVRX-820: Version 20240919\u003cbr\u003e* cMT-CTRL01: Version 20250827\u003cbr\u003e\u003cbr\u003eFor more information, see Weintek\u0027s planned notice: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e\u003cbr\u003e"
                }
              ],
              "value": "Weintek recommends users implement the following mitigation techniques: \n\n* cMT3072XH: Version 20241112\n* cMT3072XH(T): Version 20241112\n* cMT-SVRX-820: Version 20240919\n* cMT-CTRL01: Version 20250827\n\nFor more information, see Weintek\u0027s planned notice:  https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unverified Password Change in Weintek cMT X Series HMI EasyWeb Service",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-14751",
        "datePublished": "2026-01-22T21:42:50.871Z",
        "dateReserved": "2025-12-15T20:40:05.015Z",
        "dateUpdated": "2026-01-26T21:02:09.222Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14750 (GCVE-0-2025-14750)

    Vulnerability from cvelistv5 – Published: 2026-01-22 21:40 – Updated: 2026-01-26 21:01
    VLAI
    Title
    External Control of Assumed-Immutable Web Parameter in Weintek cMT X Series HMI EasyWeb Service
    Summary
    The web application does not sufficiently verify inputs that are assumed to be immutable but are actually externally controllable. A low-privileged user can modify the parameters and potentially manipulate account-level privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-472 - External Control of Assumed-Immutable Web Parameter
    Assigner
    References
    Impacted products
    Vendor Product Version
    Weintek cMT3072XH Affected: 20200630 , < 20241112 (custom)
    Create a notification for this product.
    Weintek cMT3072XH(T) Affected: 20200630 , < 20241112 (custom)
    Create a notification for this product.
    Weintek cMT-SVRX-820 Affected: 20220413 , < 20240919 (custom)
    Create a notification for this product.
    Weintek cMT-CTRL01 Affected: 20230308 , < 20250827 (custom)
    Create a notification for this product.
    Credits
    Joel Aviad Ossi of WebSec B.V reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14750",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-26T21:01:22.166872Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-26T21:01:31.626Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT3072XH",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20241112",
                  "status": "affected",
                  "version": "20200630",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3072XH(T)",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20241112",
                  "status": "affected",
                  "version": "20200630",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT-SVRX-820",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20240919",
                  "status": "affected",
                  "version": "20220413",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT-CTRL01",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "20250827",
                  "status": "affected",
                  "version": "20230308",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Joel Aviad Ossi of WebSec B.V reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The web application does not sufficiently verify inputs that are assumed to be immutable but are actually externally controllable. A low-privileged user can modify the parameters and potentially manipulate account-level privileges. \u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "The web application does not sufficiently verify inputs that are assumed to be immutable but are actually externally controllable. A low-privileged user can modify the parameters and potentially manipulate account-level privileges."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-472",
                  "description": "CWE-472 External Control of Assumed-Immutable Web Parameter",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-22T21:40:56.977Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Weintek recommends users implement the following mitigation techniques: \u003cbr\u003e\u003cbr\u003e* cMT3072XH: Version 20241112\u003cbr\u003e* cMT3072XH(T): Version 20241112\u003cbr\u003e* cMT-SVRX-820: Version 20240919\u003cbr\u003e* cMT-CTRL01: Version 20250827\u003cbr\u003e\u003cbr\u003eFor more information, see Weintek\u0027s planned notice: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\"\u003ehttps://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\u003c/a\u003e\u003cbr\u003e"
                }
              ],
              "value": "Weintek recommends users implement the following mitigation techniques: \n\n* cMT3072XH: Version 20241112\n* cMT3072XH(T): Version 20241112\n* cMT-SVRX-820: Version 20240919\n* cMT-CTRL01: Version 20250827\n\nFor more information, see Weintek\u0027s planned notice:  https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "External Control of Assumed-Immutable Web Parameter in Weintek cMT X Series HMI EasyWeb Service",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-14750",
        "datePublished": "2026-01-22T21:40:56.977Z",
        "dateReserved": "2025-12-15T20:40:03.048Z",
        "dateUpdated": "2026-01-26T21:01:31.626Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2023-5777 (GCVE-0-2023-5777)

    Vulnerability from cvelistv5 – Published: 2023-11-06 19:26 – Updated: 2025-01-16 21:26
    VLAI
    Title
    Weintek EasyBuilder Pro Use of Hard-coded Credentials
    Summary
    Weintek EasyBuilder Pro contains a vulnerability that, even when the private key is immediately deleted after the crash report transmission is finished, the private key is exposed to the public, which could result in obtaining remote control of the crash report server.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    Impacted products
    Vendor Product Version
    Weintek EasyBuilder Pro Affected: 0 , < v6.07.02 (custom)
    Affected: 0 , ≤ 6.08.01.592 (custom)
    Affected: 0 , ≤ 6.08.02.470 (custom)
    Create a notification for this product.
    Date Public
    2023-11-02 17:00
    Credits
    Hank Chen (PSIRT and Threat Research of TXOne Networks) reported this vulnerability to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T08:07:32.769Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-306-05"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-5777",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-16T21:22:21.675124Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-16T21:26:49.870Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyBuilder Pro",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThan": "v6.07.02",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.08.01.592",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.08.02.470",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Hank Chen (PSIRT and Threat Research of TXOne Networks) reported this vulnerability to CISA."
            }
          ],
          "datePublic": "2023-11-02T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWeintek EasyBuilder Pro contains a vulnerability that, even when the private key is immediately deleted after the crash report transmission is finished, the private key is exposed to the public, which could result in obtaining remote control of the crash report server.\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\n\n\nWeintek EasyBuilder Pro contains a vulnerability that, even when the private key is immediately deleted after the crash report transmission is finished, the private key is exposed to the public, which could result in obtaining remote control of the crash report server.\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-06T19:26:09.044Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-306-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eWeintek recommends users apply the following mitigations:\u003c/p\u003e\u003cul\u003e\u003cli\u003eUpdate EasyBuilder Pro to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.weintek.com/globalw/Download/Download.aspx\"\u003ev6.08.01.614\u003c/a\u003e\u003c/li\u003e\u003cli\u003eUpdate EasyBuilder Pro to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.weintek.com/globalw/Download/Download.aspx\"\u003ev6.08.02.500\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n\n\n\n\nWeintek recommends users apply the following mitigations:\n\n  *  Update EasyBuilder Pro to  v6.08.01.614 https://www.weintek.com/globalw/Download/Download.aspx \n  *  Update EasyBuilder Pro to  v6.08.02.500 https://www.weintek.com/globalw/Download/Download.aspx \n\n\n\n\n\n\n\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSA-23-306-05",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek EasyBuilder Pro Use of Hard-coded Credentials",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-5777",
        "datePublished": "2023-11-06T19:26:09.044Z",
        "dateReserved": "2023-10-25T22:32:36.999Z",
        "dateUpdated": "2025-01-16T21:26:49.870Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-43492 (GCVE-0-2023-43492)

    Vulnerability from cvelistv5 – Published: 2023-10-19 19:28 – Updated: 2025-01-16 21:28
    VLAI
    Title
    Weintek cMT3000 HMI Web CGI Stack-based Buffer Overflow
    Summary
    In Weintek's cMT3000 HMI Web CGI device, the cgi-bin codesys.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Impacted products
    Vendor Product Version
    Weintek cMT-FHD Affected: 0 , ≤ 20210210 (custom)
    Create a notification for this product.
    Weintek cMT-HDM Affected: 0 , ≤ 20210204 (custom)
    Create a notification for this product.
    Weintek cMT3071 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3072 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3103 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3090 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3151 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Date Public
    2023-10-12 17:00
    Credits
    Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T19:44:43.206Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-12"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-43492",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-16T21:22:40.211272Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-16T21:28:29.900Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT-FHD",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210210 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT-HDM",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210204 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3071",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3072",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3103",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3090",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3151",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-10-12T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIn Weintek\u0027s cMT3000 HMI Web CGI device, the cgi-bin codesys.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e"
                }
              ],
              "value": "\n\n\n\n\n\n\n\n\nIn Weintek\u0027s cMT3000 HMI Web CGI device, the cgi-bin codesys.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-19T19:28:59.236Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-12"
            },
            {
              "url": "https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\n\n\u003cp\u003eWeintek recommends users follow their \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/UM0/UM018010E_cMT_Series_OS_Update_Instructions_eng.pdf\"\u003eUpgrade Instructions\u003c/a\u003e\u0026nbsp;to update the following products to the latest versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003ecMT-FHD: OS version 20210211\u003c/li\u003e\u003cli\u003ecMT-HDM: OS version 20210205\u003c/li\u003e\u003cli\u003ecMT3071: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3072: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3103: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3090: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3151: OS version 20210219\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor additional information, refer to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf\"\u003eWeintek\u0027s security bulletin\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n\n\n\n\nWeintek recommends users follow their  Upgrade Instructions https://dl.weintek.com/public/Document/UM0/UM018010E_cMT_Series_OS_Update_Instructions_eng.pdf \u00a0to update the following products to the latest versions:\n\n  *  cMT-FHD: OS version 20210211\n  *  cMT-HDM: OS version 20210205\n  *  cMT3071: OS version 20210219\n  *  cMT3072: OS version 20210219\n  *  cMT3103: OS version 20210219\n  *  cMT3090: OS version 20210219\n  *  cMT3151: OS version 20210219\n\n\nFor additional information, refer to  Weintek\u0027s security bulletin https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf .\n\n\n\n\n\n\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSMA-23-285-12",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek cMT3000 HMI Web CGI Stack-based Buffer Overflow",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-43492",
        "datePublished": "2023-10-19T19:28:59.236Z",
        "dateReserved": "2023-09-20T14:26:47.014Z",
        "dateUpdated": "2025-01-16T21:28:29.900Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-40145 (GCVE-0-2023-40145)

    Vulnerability from cvelistv5 – Published: 2023-10-19 19:26 – Updated: 2025-01-16 21:28
    VLAI
    Title
    Weintek cMT3000 HMI Web CGI OS Command Injection
    Summary
    In Weintek's cMT3000 HMI Web CGI device, an anonymous attacker can execute arbitrary commands after login to the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - OS Command Injection
    Assigner
    Impacted products
    Vendor Product Version
    Weintek cMT-FHD Affected: 0 , ≤ 20210210 (custom)
    Create a notification for this product.
    Weintek cMT-HDM Affected: 0 , ≤ 20210204 (custom)
    Create a notification for this product.
    Weintek cMT3071 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3072 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3103 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3090 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3151 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Date Public
    2023-10-12 17:00
    Credits
    Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T18:24:55.542Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-12"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-40145",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-16T21:20:09.729366Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-16T21:28:39.035Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT-FHD",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210210 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT-HDM",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210204 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3071",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3072",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3103",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3090",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3151",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-10-12T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIn Weintek\u0027s cMT3000 HMI Web CGI device, an anonymous attacker can execute arbitrary commands after login to the device.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e"
                }
              ],
              "value": "\n\n\n\n\n\n\n\n\nIn Weintek\u0027s cMT3000 HMI Web CGI device, an anonymous attacker can execute arbitrary commands after login to the device.\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-19T19:26:20.948Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-12"
            },
            {
              "url": "https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\n\n\u003cp\u003eWeintek recommends users follow their \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/UM0/UM018010E_cMT_Series_OS_Update_Instructions_eng.pdf\"\u003eUpgrade Instructions\u003c/a\u003e\u0026nbsp;to update the following products to the latest versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003ecMT-FHD: OS version 20210211\u003c/li\u003e\u003cli\u003ecMT-HDM: OS version 20210205\u003c/li\u003e\u003cli\u003ecMT3071: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3072: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3103: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3090: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3151: OS version 20210219\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor additional information, refer to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf\"\u003eWeintek\u0027s security bulletin\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n\n\n\n\nWeintek recommends users follow their  Upgrade Instructions https://dl.weintek.com/public/Document/UM0/UM018010E_cMT_Series_OS_Update_Instructions_eng.pdf \u00a0to update the following products to the latest versions:\n\n  *  cMT-FHD: OS version 20210211\n  *  cMT-HDM: OS version 20210205\n  *  cMT3071: OS version 20210219\n  *  cMT3072: OS version 20210219\n  *  cMT3103: OS version 20210219\n  *  cMT3090: OS version 20210219\n  *  cMT3151: OS version 20210219\n\n\nFor additional information, refer to  Weintek\u0027s security bulletin https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf .\n\n\n\n\n\n\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSMA-23-285-12",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek cMT3000 HMI Web CGI OS Command Injection",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-40145",
        "datePublished": "2023-10-19T19:26:20.948Z",
        "dateReserved": "2023-09-20T14:26:47.028Z",
        "dateUpdated": "2025-01-16T21:28:39.035Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-38584 (GCVE-0-2023-38584)

    Vulnerability from cvelistv5 – Published: 2023-10-19 19:20 – Updated: 2025-01-16 21:28
    VLAI
    Title
    Weintek cMT3000 HMI Web CGI Stack-based Buffer Overflow
    Summary
    In Weintek's cMT3000 HMI Web CGI device, the cgi-bin command_wb.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Impacted products
    Vendor Product Version
    Weintek cMT-FHD Affected: 0 , ≤ 20210210 (custom)
    Create a notification for this product.
    Weintek cMT-HDM Affected: 0 , ≤ 20210204 (custom)
    Create a notification for this product.
    Weintek cMT3071 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3072 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3103 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3090 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Weintek cMT3151 Affected: 0 , ≤ 20210218 (custom)
    Create a notification for this product.
    Date Public
    2023-10-12 17:00
    Credits
    Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:46:56.458Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-12"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-38584",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-16T21:22:44.800664Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-16T21:28:46.086Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cMT-FHD",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210210 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT-HDM",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210204 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3071",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3072",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3103",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3090",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "cMT3151",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "20210218",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-10-12T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIn Weintek\u0027s cMT3000 HMI Web CGI device, the cgi-bin command_wb.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.\u003c/span\u003e\n\n\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e"
                }
              ],
              "value": "\n\n\n\n\n\n\nIn Weintek\u0027s cMT3000 HMI Web CGI device, the cgi-bin command_wb.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-19T19:20:20.059Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-12"
            },
            {
              "url": "https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\n\n\u003cp\u003eWeintek recommends users follow their \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/UM0/UM018010E_cMT_Series_OS_Update_Instructions_eng.pdf\"\u003eUpgrade Instructions\u003c/a\u003e\u0026nbsp;to update the following products to the latest versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003ecMT-FHD: OS version 20210211\u003c/li\u003e\u003cli\u003ecMT-HDM: OS version 20210205\u003c/li\u003e\u003cli\u003ecMT3071: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3072: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3103: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3090: OS version 20210219\u003c/li\u003e\u003cli\u003ecMT3151: OS version 20210219\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor additional information, refer to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf\"\u003eWeintek\u0027s security bulletin\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n\n\n\n\nWeintek recommends users follow their  Upgrade Instructions https://dl.weintek.com/public/Document/UM0/UM018010E_cMT_Series_OS_Update_Instructions_eng.pdf \u00a0to update the following products to the latest versions:\n\n  *  cMT-FHD: OS version 20210211\n  *  cMT-HDM: OS version 20210205\n  *  cMT3071: OS version 20210219\n  *  cMT3072: OS version 20210219\n  *  cMT3103: OS version 20210219\n  *  cMT3090: OS version 20210219\n  *  cMT3151: OS version 20210219\n\n\nFor additional information, refer to  Weintek\u0027s security bulletin https://dl.weintek.com/public/Document/TEC/TEC23005E_cMT_Web_Security_Update.pdf .\n\n\n\n\n\n\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSMA-23-285-12",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek cMT3000 HMI Web CGI Stack-based Buffer Overflow",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-38584",
        "datePublished": "2023-10-19T19:20:20.059Z",
        "dateReserved": "2023-09-20T14:26:47.021Z",
        "dateUpdated": "2025-01-16T21:28:46.086Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-37362 (GCVE-0-2023-37362)

    Vulnerability from cvelistv5 – Published: 2023-07-19 21:50 – Updated: 2025-03-06 15:04
    VLAI
    Title
    Weintek Weincloud Improper Authentication
    Summary
    Weintek Weincloud v0.13.6 could allow an attacker to abuse the registration functionality to login with testing credentials to the official website.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-522 - Insufficiently Protected Credentials
    Assigner
    Impacted products
    Vendor Product Version
    Weintek Weincloud Affected: 0 , ≤ 0.13.6 (custom)
    Create a notification for this product.
    Date Public
    2023-07-18 17:00
    Credits
    ​Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:09:34.107Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-37362",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-28T14:20:12.749745Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-28T14:20:20.599Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Weincloud",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "0.13.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "\u200bHank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-07-18T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWeintek Weincloud v\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e0.13.6\u003c/span\u003e\n\n \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ecould allow an attacker to abuse the registration functionality to login with testing credentials to the official website.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Weintek Weincloud v0.13.6\n\n \n\ncould allow an attacker to abuse the registration functionality to login with testing credentials to the official website."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-522",
                  "description": "CWE-522 Insufficiently Protected Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-03-06T15:04:53.644Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users.\u003c/p\u003e\u003cp\u003e\u003cbr\u003e\u003c/p\u003e"
                }
              ],
              "value": "\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users."
            }
          ],
          "source": {
            "advisory": "ICSA-23-199-04",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek Weincloud Improper Authentication",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\u200bAdditional mitigations are recommended to help reduce risk:\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\u003c/li\u003e\u003cli\u003e\u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\u003c/li\u003e\u003cli\u003e\u200bRegularly change passwords to reduce risks.\u003c/li\u003e\u003cli\u003e\u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\u200bAdditional mitigations are recommended to help reduce risk:\n\n  *  \u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\n  *  \u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\n  *  \u200bRegularly change passwords to reduce risks.\n  *  \u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-37362",
        "datePublished": "2023-07-19T21:50:42.036Z",
        "dateReserved": "2023-07-13T15:55:48.885Z",
        "dateUpdated": "2025-03-06T15:04:53.644Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-32657 (GCVE-0-2023-32657)

    Vulnerability from cvelistv5 – Published: 2023-07-19 21:47 – Updated: 2024-10-28 14:20
    VLAI
    Title
    Weintek Weincloud Improper Restriction of Excessive Authentication Attempts
    Summary
    Weintek Weincloud v0.13.6 could allow an attacker to efficiently develop a brute force attack on credentials with authentication hints from error message responses.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-307 - Improper Restriction of Excessive Authentication Attempts
    Assigner
    Impacted products
    Vendor Product Version
    Weintek Weincloud Affected: 0 , ≤ 0.13.6 (custom)
    Create a notification for this product.
    Date Public
    2023-07-18 17:00
    Credits
    ​Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:25:36.554Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-32657",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-28T14:20:43.540823Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-28T14:20:52.959Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Weincloud",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "0.13.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "\u200bHank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-07-18T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWeintek Weincloud v\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e0.13.6\u003c/span\u003e\n\n \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ecould \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eallow an attacker to efficiently develop a brute force attack on credentials with authentication hints from error message responses.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\n\n\nWeintek Weincloud v0.13.6\n\n \n\ncould allow an attacker to efficiently develop a brute force attack on credentials with authentication hints from error message responses.\n\n\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-307",
                  "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-19T21:47:37.160Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users.\u003c/p\u003e\u003cp\u003e\u003cbr\u003e\u003c/p\u003e"
                }
              ],
              "value": "\n\n\n\n\n\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users.\n\n\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSA-23-199-04",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek Weincloud Improper Restriction of Excessive Authentication Attempts",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003e\u200bAdditional mitigations are recommended to help reduce risk:\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\u003c/li\u003e\u003cli\u003e\u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\u003c/li\u003e\u003cli\u003e\u200bRegularly change passwords to reduce risks.\u003c/li\u003e\u003cli\u003e\u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n\u200bAdditional mitigations are recommended to help reduce risk:\n\n  *  \u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\n  *  \u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\n  *  \u200bRegularly change passwords to reduce risks.\n  *  \u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet.\n\n\n\n\n\n"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-32657",
        "datePublished": "2023-07-19T21:47:37.160Z",
        "dateReserved": "2023-07-13T15:55:48.890Z",
        "dateUpdated": "2024-10-28T14:20:52.959Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-34429 (GCVE-0-2023-34429)

    Vulnerability from cvelistv5 – Published: 2023-07-19 21:45 – Updated: 2024-10-28 14:29
    VLAI
    Title
    Weintek Weincloud Improper Handling of Structural Elements
    Summary
    Weintek Weincloud v0.13.6 could allow an attacker to cause a denial-of-service condition for Weincloud by sending a forged JWT token.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-237 - Improper Handling of Structural Elements
    Assigner
    Impacted products
    Vendor Product Version
    Weintek Weincloud Affected: 0 , ≤ 0.13.6 (custom)
    Create a notification for this product.
    Date Public
    2023-07-18 17:00
    Credits
    ​Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:10:07.023Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-34429",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-28T14:29:27.447079Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-28T14:29:40.049Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Weincloud",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "0.13.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "\u200bHank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-07-18T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWeintek Weincloud v\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e0.13.6\u003c/span\u003e\n\n \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ecould \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eallow an attacker to cause a denial-of-service condition for Weincloud by sending a forged JWT token.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\n\n\nWeintek Weincloud v0.13.6\n\n \n\ncould allow an attacker to cause a denial-of-service condition for Weincloud by sending a forged JWT token.\n\n\n\n\n\n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-237",
                  "description": "CWE-237 Improper Handling of Structural Elements",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-19T21:45:39.544Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users.\u003c/p\u003e\u003cp\u003e\u200b\u003c/p\u003e"
                }
              ],
              "value": "\n\n\n\n\n\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users.\n\n\u200b\n\n"
            }
          ],
          "source": {
            "advisory": "ICSA-23-199-04",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek Weincloud Improper Handling of Structural Elements",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003eAdditional mitigations are recommended to help reduce risk:\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\u003c/li\u003e\u003cli\u003e\u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\u003c/li\u003e\u003cli\u003e\u200bRegularly change passwords to reduce risks.\u003c/li\u003e\u003cli\u003e\u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nAdditional mitigations are recommended to help reduce risk:\n\n  *  \u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\n  *  \u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\n  *  \u200bRegularly change passwords to reduce risks.\n  *  \u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet.\n\n\n\n\n\n"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-34429",
        "datePublished": "2023-07-19T21:45:39.544Z",
        "dateReserved": "2023-07-13T15:55:48.894Z",
        "dateUpdated": "2024-10-28T14:29:40.049Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-35134 (GCVE-0-2023-35134)

    Vulnerability from cvelistv5 – Published: 2023-07-19 21:43 – Updated: 2024-10-28 14:30
    VLAI
    Title
    Weintek Weincloud Weak Password Recovery Mechanism for Forgotten Password
    Summary
    Weintek Weincloud v0.13.6 could allow an attacker to reset a password with the corresponding account’s JWT token only.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-640 - Weak Password Recovery Mechanism for Forgotten Password
    Assigner
    Impacted products
    Vendor Product Version
    Weintek Weincloud Affected: 0 , ≤ 0.13.6 (custom)
    Create a notification for this product.
    Date Public
    2023-07-18 17:00
    Credits
    ​Hank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:23:59.280Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-35134",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-28T14:29:57.942492Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-28T14:30:07.804Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Weincloud",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "0.13.6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "\u200bHank Chen (PSIRT and Threat Research of TXOne Networks) reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-07-18T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWeintek Weincloud v\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e0.13.6\u003c/span\u003e\n\n could allow an attacker to reset a password with the corresponding account\u2019s JWT token only.\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\n\n\nWeintek Weincloud v0.13.6\n\n could allow an attacker to reset a password with the corresponding account\u2019s JWT token only.\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-640",
                  "description": "CWE-640 Weak Password Recovery Mechanism for Forgotten Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-19T21:43:20.562Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-199-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users.\u003c/p\u003e\u003cp\u003e\u003cbr\u003e\u003c/p\u003e"
                }
              ],
              "value": "\n\n\n\n\n\u200bWeintek has updated their account API to v0.13.8, which has fixed the issue. This fix does not require any action for users.\n\n\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSA-23-199-04",
            "discovery": "EXTERNAL"
          },
          "title": "Weintek Weincloud Weak Password Recovery Mechanism for Forgotten Password",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003e\u200bAdditional mitigations are recommended to help reduce risk:\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\u003c/li\u003e\u003cli\u003e\u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\u003c/li\u003e\u003cli\u003e\u200bRegularly change passwords to reduce risks.\u003c/li\u003e\u003cli\u003e\u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n\u200bAdditional mitigations are recommended to help reduce risk:\n\n  *  \u200bLog in on trusted computers if possible. Log out after usage on un-trusted ones.\n  *  \u200bOn the HMIs, if the online services are not used, set to offline mode for EasyAccess 2.0 or Dashboard services using system reserved addresses.\n  *  \u200bRegularly change passwords to reduce risks.\n  *  \u200bMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible- only applicable devices and/or systems have access to the internet.\n\n\n\n\n\n"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-35134",
        "datePublished": "2023-07-19T21:43:20.562Z",
        "dateReserved": "2023-07-13T15:55:48.879Z",
        "dateUpdated": "2024-10-28T14:30:07.804Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-0104 (GCVE-0-2023-0104)

    Vulnerability from cvelistv5 – Published: 2023-02-22 20:25 – Updated: 2025-01-16 21:55
    VLAI
    Summary
    The listed versions for Weintek EasyBuilder Pro are vulnerable to a ZipSlip attack caused by decompiling a malicious project file. This may allow an attacker to gain control of the user’s computer or gain access to sensitive data.  
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-29 - Path Traversal: '\..\filename'
    Assigner
    Impacted products
    Vendor Product Version
    Weintek EasyBuilder Pro cMT Affected: 0 , ≤ 6.07.01 (custom)
    Affected: 0 , ≤ 6.07.02.479 (custom)
    Affected: 0 , ≤ 6.08.01.349 (custom)
    Create a notification for this product.
    Credits
    Hank Chen and Mars Cheng of PSIRT and Threat Research of TXOne Networks reported this vulnerability to CISA. Patrick Kuo of TXOne Networks also contributed to this research.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:02:43.504Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-045-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-0104",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-16T20:21:56.130362Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-16T21:55:59.469Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EasyBuilder Pro cMT ",
              "vendor": "Weintek",
              "versions": [
                {
                  "lessThanOrEqual": "6.07.01",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.07.02.479 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.08.01.349 ",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Hank Chen and Mars Cheng of PSIRT and Threat Research of TXOne Networks reported this vulnerability to CISA. Patrick Kuo of TXOne Networks also contributed to this research."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003eThe listed versions for Weintek EasyBuilder Pro are vulnerable to a ZipSlip attack caused by decompiling a malicious project file. This may allow an attacker to gain control of the user\u2019s computer or gain access to sensitive data. \u0026nbsp; \u003c/p\u003e\u003cbr\u003e\n\n"
                }
              ],
              "value": "\nThe listed versions for Weintek EasyBuilder Pro are vulnerable to a ZipSlip attack caused by decompiling a malicious project file. This may allow an attacker to gain control of the user\u2019s computer or gain access to sensitive data. \u00a0 \n\n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-29",
                  "description": "CWE-29 Path Traversal: \u0027\\..\\filename\u0027",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-22T20:25:04.680Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-045-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: var(--wht);\"\u003eWeintek recommends users to implement the following\nmitigation techniques:\u003c/span\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nUpgrade EasyBuilder Pro to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/EBPro/Installer/EBproV60702480.zip\"\u003ev6.07.02.480\u003c/a\u003e,\n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://dl.weintek.com/EBPro/Installer/EBproV60801350.zip\"\u003ev6.08.01.350\u003c/a\u003e\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nUse Decompile only on trusted sources and only when\nneeded.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
                }
              ],
              "value": "Weintek recommends users to implement the following\nmitigation techniques:\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nUpgrade EasyBuilder Pro to  v6.07.02.480 https://dl.weintek.com/EBPro/Installer/EBproV60702480.zip ,\n v6.08.01.350 https://dl.weintek.com/EBPro/Installer/EBproV60801350.zip \nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nUse Decompile only on trusted sources and only when\nneeded.\n\n\n\n\n\n\n\n\n"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-0104",
        "datePublished": "2023-02-22T20:25:04.680Z",
        "dateReserved": "2023-01-06T18:50:05.156Z",
        "dateUpdated": "2025-01-16T21:55:59.469Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }