CVE-2026-50610 (GCVE-0-2026-50610)
Vulnerability from nvd – Published: 2026-09-17 08:26 – Updated: 2026-09-17 12:18
VLAI
EPSS
VEX
Title
Improper Access control Vulnerability in NitroSense and PredatorSense Software
Summary
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications, potentially resulting in local privilege escalation.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 12:16 UTC
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | System Monitoring |
Affected:
* , ≤ 1.0.19.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50610",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T12:16:15.601033Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T12:18:12.672Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "System Monitoring",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.0.19.2",
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Cassius GARAT"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications, potentially resulting in local privilege escalation."
}
],
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications, potentially resulting in local privilege escalation."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233: Privilege Escalation"
}
]
},
{
"capecId": "CAPEC-180",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-180: Exploiting Incorrectly Configured Access Control Security Levels"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T08:26:21.362Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19877"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Update to one of the following versions or later:\n\n * NitroSense v5.2.84\n * PredatorSense v5.2.109"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Improper Access control Vulnerability in NitroSense and PredatorSense Software",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50610",
"datePublished": "2026-09-17T08:26:21.362Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T12:18:12.672Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50609 (GCVE-0-2026-50609)
Vulnerability from nvd – Published: 2026-09-17 08:21 – Updated: 2026-09-17 12:24
VLAI
EPSS
VEX
Title
Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software
Summary
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 12:23 UTC
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | System Monitoring |
Affected:
* , ≤ 1.0.19.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50609",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T12:23:07.250428Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T12:24:11.273Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "System Monitoring",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.0.19.2",
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Cassius GARAT"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system."
}
],
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system."
}
],
"impacts": [
{
"capecId": "CAPEC-180",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
}
]
},
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T08:21:29.786Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19876"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Update to one of the following versions or later:\n\n * NitroSense v5.2.84\n * PredatorSense v5.2.109"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50609",
"datePublished": "2026-09-17T08:21:29.786Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T12:24:11.273Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50608 (GCVE-0-2026-50608)
Vulnerability from nvd – Published: 2026-09-17 08:15 – Updated: 2026-09-17 12:25
VLAI
EPSS
VEX
Title
Authentication Vulnerability in NitroSense and PredatorSense Software
Summary
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The WebSocket handshake process does not properly require authentication before allowing connections to the service. Under certain circumstances, unauthorized access to service functionality may be possible.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 12:25 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | System Monitoring |
Affected:
* , ≤ 1.0.19.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50608",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T12:25:32.773472Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T12:25:51.670Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "System Monitoring",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.0.19.2",
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Ayush Choudhary"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The WebSocket handshake process does not properly require authentication before allowing connections to the service. Under certain circumstances, unauthorized access to service functionality may be possible."
}
],
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The WebSocket handshake process does not properly require authentication before allowing connections to the service. Under certain circumstances, unauthorized access to service functionality may be possible."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 1.2,
"baseSeverity": "LOW",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T08:15:17.327Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19875"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Update to one of the following versions or later:\n\n * NitroSense v5.2.84\n * PredatorSense v5.2.109"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authentication Vulnerability in NitroSense and PredatorSense Software",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50608",
"datePublished": "2026-09-17T08:15:17.327Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T12:25:51.670Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50607 (GCVE-0-2026-50607)
Vulnerability from nvd – Published: 2026-09-17 08:05 – Updated: 2026-09-17 12:26
VLAI
EPSS
VEX
Title
WebSocket Exposure Vulnerability in NitroSense and PredatorSense Software
Summary
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 12:26 UTC
CWE
- CWE-668 - All-Interface Binding
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | System Monitoring |
Affected:
* , ≤ 1.0.19.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50607",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T12:26:05.665465Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T12:26:18.604Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "System Monitoring",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.0.19.2",
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Tolga Cohce"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access."
}
],
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access."
}
],
"impacts": [
{
"capecId": "CAPEC-118",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-118: Collect and Analyze Information"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 2.7,
"baseSeverity": "LOW",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 All-Interface Binding",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T08:22:19.514Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19879"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "WebSocket Exposure Vulnerability in NitroSense and PredatorSense Software",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50607",
"datePublished": "2026-09-17T08:05:44.472Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T12:26:18.604Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50606 (GCVE-0-2026-50606)
Vulnerability from nvd – Published: 2026-09-17 07:59 – Updated: 2026-09-17 12:30
VLAI
EPSS
VEX
Title
Hard-coded Encryption Key Vulnerability in Acer System Monitoring for NitroSense and PredatorSense Software
Summary
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 12:26 UTC
CWE
- CWE-321 - Hardcoded AES-128-ECB Key
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | System Monitoring |
Affected:
* , ≤ 1.0.19.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50606",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T12:26:30.763323Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T12:30:03.105Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "System Monitoring",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.0.19.2",
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Tolga Cohce"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
}
],
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126 Leveraging Hard-coded Credentials"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 1.2,
"baseSeverity": "LOW",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321 Hardcoded AES-128-ECB Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T08:01:19.643Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19873"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Update to one of the following versions or later:\n\n * NitroSense v5.2.84\n * PredatorSense v5.2.109"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Hard-coded Encryption Key Vulnerability in Acer System Monitoring for NitroSense and PredatorSense Software",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50606",
"datePublished": "2026-09-17T07:59:52.258Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T12:30:03.105Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50605 (GCVE-0-2026-50605)
Vulnerability from nvd – Published: 2026-09-17 07:53 – Updated: 2026-09-17 12:31
VLAI
EPSS
VEX
Title
Privilege Escalation Vulnerability in NitroSense and PredatorSense Software
Summary
A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. Insufficient access controls within a privileged service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 12:31 UTC
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | Agent Serivce |
Affected:
* , ≤ 1.2.110.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50605",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T12:31:23.408055Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T12:31:34.878Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Agent Serivce",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.2.110.2",
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. Insufficient access controls within a privileged service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system."
}
],
"value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. Insufficient access controls within a privileged service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
},
{
"capecId": "CAPEC-180",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T07:53:44.292Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19872"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Update to one of the following versions or later:\n\n * NitroSense v5.2.84\n * PredatorSense v5.2.109"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Privilege Escalation Vulnerability in NitroSense and PredatorSense Software",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50605",
"datePublished": "2026-09-17T07:53:44.292Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T12:31:34.878Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50604 (GCVE-0-2026-50604)
Vulnerability from nvd – Published: 2026-09-17 04:06 – Updated: 2026-09-17 12:52
VLAI
EPSS
VEX
Title
Unauthenticated Access Vulnerability in NitroSense and PredatorSense Software
Summary
A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The socket handshake process does not properly require authentication before granting access to the service. Under certain circumstances, an unauthorized connection may be established, potentially allowing access to functionality that should be restricted.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 12:52 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | Agent Service |
Affected:
* , ≤ 1.2.110.2
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50604",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T12:52:33.105111Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T12:52:56.787Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Agent Service",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.2.110.2",
"status": "affected",
"version": "*",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Tolga Cohce"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The socket handshake process does not properly require authentication before granting access to the service. Under certain circumstances, an unauthorized connection may be established, potentially allowing access to functionality that should be restricted."
}
],
"value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The socket handshake process does not properly require authentication before granting access to the service. Under certain circumstances, an unauthorized connection may be established, potentially allowing access to functionality that should be restricted."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T07:55:36.264Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19871"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Update to one of the following versions or later:\n\n * NitroSense v5.2.84\n * PredatorSense v5.2.109"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unauthenticated Access Vulnerability in NitroSense and PredatorSense Software",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50604",
"datePublished": "2026-09-17T04:06:40.354Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T12:52:56.787Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50603 (GCVE-0-2026-50603)
Vulnerability from nvd – Published: 2026-09-17 04:01 – Updated: 2026-09-17 14:48
VLAI
EPSS
VEX
Title
Hard-coded encryption key vulnerability in Acer Agent Service for NitroSense and PredatorSense
Summary
A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 14:47 UTC
CWE
- CWE-321 - Hardcoded AES-128-ECB Key
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | Agent Service |
Affected:
* , ≤ 1.2.110.2
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50603",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T14:47:57.377766Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T14:48:17.751Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Agent Service",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.2.110.2",
"status": "affected",
"version": "*",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Tolga Cohce"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
}
],
"value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126 Leveraging Hard-coded Credentials"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321 Hardcoded AES-128-ECB Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T07:54:47.332Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19878"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Update to one of the following versions or later:\n\n * NitroSense v5.2.84\n * PredatorSense v5.2.109"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Hard-coded encryption key vulnerability in Acer Agent Service for NitroSense and PredatorSense",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50603",
"datePublished": "2026-09-17T04:01:12.295Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T14:48:17.751Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50602 (GCVE-0-2026-50602)
Vulnerability from nvd – Published: 2026-08-17 02:16 – Updated: 2026-08-17 15:55
VLAI
EPSS
VEX
Title
Planet9 Incorrect Permission Assignment Vulnerability Information
Summary
A security vulnerability has been identified in Planet9 due to incorrect file permissions assigned to an application executable used by the Planet9 background service. The service runs with SYSTEM privileges, while the affected executable grants excessive permissions to non-administrative users. As a result, an authenticated local user could potentially modify or replace the executable and execute arbitrary code with SYSTEM privileges when the service starts or the system is restarted.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-17 15:54 UTC
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | Planet9 background service |
Affected:
NA
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50602",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-17T15:54:48.740071Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T15:55:59.301Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Planet9 background service",
"vendor": "Acer",
"versions": [
{
"status": "affected",
"version": "NA",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Tolga C\u00f6hce"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A security vulnerability has been identified in Planet9 due to incorrect file permissions assigned to an application executable used by the Planet9 background service. The service runs with SYSTEM privileges, while the affected executable grants excessive permissions to non-administrative users. As a result, an authenticated local user could potentially modify or replace the executable and execute arbitrary code with SYSTEM privileges when the service starts or the system is restarted."
}
],
"value": "A security vulnerability has been identified in Planet9 due to incorrect file permissions assigned to an application executable used by the Planet9 background service. The service runs with SYSTEM privileges, while the affected executable grants excessive permissions to non-administrative users. As a result, an authenticated local user could potentially modify or replace the executable and execute arbitrary code with SYSTEM privileges when the service starts or the system is restarted."
}
],
"impacts": [
{
"capecId": "CAPEC-234",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-234 Hijacking a Privileged Process"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T02:16:49.131Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19870"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An update is available that resolves this vulnerability by removing the affected executable files and uninstalling the background service (\u003ccode\u003ePLANET9DAService\u003c/code\u003e). Planet9 will automatically upgrade to the latest version."
}
],
"value": "An update is available that resolves this vulnerability by removing the affected executable files and uninstalling the background service (PLANET9DAService). Planet9 will automatically upgrade to the latest version."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Planet9 Incorrect Permission Assignment Vulnerability Information",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50602",
"datePublished": "2026-08-17T02:16:49.131Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-08-17T15:55:59.301Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50601 (GCVE-0-2026-50601)
Vulnerability from nvd – Published: 2026-08-17 02:02 – Updated: 2026-08-17 15:57
VLAI
EPSS
VEX
Title
Planet9 Hardcoded Credentials Vulnerability Information
Summary
A security vulnerability has been identified in the Planet9 desktop application where a hardcoded read-only API key permitted unauthorized access to internal repositories. An attacker could exploit this access to extract embedded administrative keys and secrets, potentially allowing them to gain administrative access to repository infrastructure and modify software source code. To mitigate this security risk, Acer has released an update to resolve the issue.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-17 15:56 UTC
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | Planet9 desktop application |
Affected:
2.6.131 , ≤ 2.8.124
(custom)
|
Date Public
2026-08-17 01:54
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50601",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-17T15:56:35.523735Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T15:57:28.016Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows",
"64 bit"
],
"product": "Planet9 desktop application",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "2.8.124",
"status": "affected",
"version": "2.6.131",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Ayush Choudhary"
}
],
"datePublic": "2026-08-17T01:54:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A security vulnerability has been identified in the Planet9 desktop application where a hardcoded read-only API key permitted unauthorized access to internal repositories. An attacker could exploit this access to extract embedded administrative keys and secrets, potentially allowing them to gain administrative access to repository infrastructure and modify software source code. To mitigate this security risk, Acer has released an update to resolve the issue."
}
],
"value": "A security vulnerability has been identified in the Planet9 desktop application where a hardcoded read-only API key permitted unauthorized access to internal repositories. An attacker could exploit this access to extract embedded administrative keys and secrets, potentially allowing them to gain administrative access to repository infrastructure and modify software source code. To mitigate this security risk, Acer has released an update to resolve the issue."
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37: Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T02:02:40.508Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19869"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Planet9 Version v2.8.128 contains a resolution to this vulnerability. The application will automatically update to the patched version (v2.8.128) in the background."
}
],
"value": "Planet9 Version v2.8.128 contains a resolution to this vulnerability. The application will automatically update to the patched version (v2.8.128) in the background."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Planet9 Hardcoded Credentials Vulnerability Information",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50601",
"datePublished": "2026-08-17T02:02:40.508Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-08-17T15:57:28.016Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-9789 (GCVE-0-2026-9789)
Vulnerability from nvd – Published: 2026-05-28 02:39 – Updated: 2026-05-28 13:12
VLAI
EPSS
VEX
Title
NitroSense V3: Security Vulnerability Information
Summary
A Local Privilege Escalation (LPE) vulnerability affects Acer NitroSense software versions prior to 3.01.3052. The vulnerability stems from the the PSAdminAgent service, which creates a Named Pipe with a weak Access Control List (ACL). This allows any authenticated local user to connect and send commands. Because the service does not check the caller's privileges before running file deletion commands, a low-privileged local user can exploit this to delete arbitrary files with system authority.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-28 13:11 UTC
CWE
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | NitrorSense V3 |
Affected:
3.01.3001 , ≤ 3.01.3052
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9789",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T13:11:55.727489Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T13:12:02.598Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "NitrorSense V3",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "3.01.3052",
"status": "affected",
"version": "3.01.3001",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Vo Duc Thang"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A Local Privilege Escalation (LPE) vulnerability affects Acer NitroSense software versions prior to 3.01.3052. The vulnerability stems from the the PSAdminAgent service, which creates a Named Pipe with a weak Access Control List (ACL). This allows any authenticated local user to connect and send commands. Because the service does not check the caller\u0027s privileges before running file deletion commands, a low-privileged local user can exploit this to delete arbitrary files with system authority."
}
],
"value": "A Local Privilege Escalation (LPE) vulnerability affects Acer NitroSense software versions prior to 3.01.3052. The vulnerability stems from the the PSAdminAgent service, which creates a Named Pipe with a weak Access Control List (ACL). This allows any authenticated local user to connect and send commands. Because the service does not check the caller\u0027s privileges before running file deletion commands, a low-privileged local user can exploit this to delete arbitrary files with system authority."
}
],
"impacts": [
{
"capecId": "CAPEC-69",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-69 Target Programs with Elevated Privileges"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269: Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T02:39:40.930Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19670"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This issue is resolved in NitroSense versions V3.01.3056."
}
],
"value": "This issue is resolved in NitroSense versions V3.01.3056."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "NitroSense V3: Security Vulnerability Information",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-9789",
"datePublished": "2026-05-28T02:39:40.930Z",
"dateReserved": "2026-05-28T02:16:31.420Z",
"dateUpdated": "2026-05-28T13:12:02.598Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-9490 (GCVE-0-2026-9490)
Vulnerability from nvd – Published: 2026-05-25 07:25 – Updated: 2026-05-26 14:43
VLAI
EPSS
VEX
Title
Acer Care Center creates a Named Pipe with a weak Security Descriptor
Summary
A security vulnerability has been identified in Acer Care Center where the ACCSvc service creates a Named Pipe with a weak Security Descriptor. This vulnerability allows an authenticated local user to connect and send a specially crafted message (message type 0x03) to the pipe, causing the service to crash with exit code 1067 (ERROR_PROCESS_ABORTED). To mitigate this potential local service disruption, Acer requires users to update the software to the latest version.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-26 14:37 UTC
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | Care Center |
Affected:
4.0 , ≤ 4.00.3058
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9490",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T14:37:24.296733Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T14:43:23.306Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Care Center",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "4.00.3058",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Vo Duc Thang"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A security vulnerability has been identified in Acer Care Center where the ACCSvc service creates a Named Pipe with a weak Security Descriptor. This vulnerability allows an authenticated local user to connect and send a specially crafted message (message type 0x03) to the pipe, causing the service to crash with exit code 1067 (ERROR_PROCESS_ABORTED). To mitigate this potential local service disruption, Acer requires users to update the software to the latest version."
}
],
"value": "A security vulnerability has been identified in Acer Care Center where the ACCSvc service creates a Named Pipe with a weak Security Descriptor. This vulnerability allows an authenticated local user to connect and send a specially crafted message (message type 0x03) to the pipe, causing the service to crash with exit code 1067 (ERROR_PROCESS_ABORTED). To mitigate this potential local service disruption, Acer requires users to update the software to the latest version."
}
],
"impacts": [
{
"capecId": "CAPEC-610",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-610: Inter-Process Communication (IPC) Misconfiguration"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/RE:M",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-25T07:25:02.310Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19668"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Please update to v4.00.3060."
}
],
"value": "Please update to v4.00.3060."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Acer Care Center creates a Named Pipe with a weak Security Descriptor",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-9490",
"datePublished": "2026-05-25T07:25:02.310Z",
"dateReserved": "2026-05-25T01:34:19.934Z",
"dateUpdated": "2026-05-26T14:43:23.306Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-9489 (GCVE-0-2026-9489)
Vulnerability from nvd – Published: 2026-05-25 01:50 – Updated: 2026-05-26 15:20
VLAI
EPSS
VEX
Title
NitroSense V3: Local Privilege Escalation (LPE) vulnerability
Summary
NitroSense 3.x before 3.01.3052 contains Local Privilege Escalation (LPE) vulnerability.The program exposes a Windows Named Pipe that uses a custom protocol to invoke internal functions. However, this Named Pipe is misconfigured, allowing any authenticated local user to execute arbitrary code with NT AUTHORITY\SYSTEM privileges and to delete arbitrary files with SYSTEM privileges. By leveraging this, an attacker can execute arbitrary code on the target system with elevated privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-26 15:11 UTC
CWE
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | NitrorSense V3 |
Affected:
3.01.3001 , ≤ 3.01.3052
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9489",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T15:11:04.376350Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T15:20:21.624Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "NitrorSense V3",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "3.01.3052",
"status": "affected",
"version": "3.01.3001",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Artem Domarev"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "NitroSense 3.x before 3.01.3052 contains Local Privilege Escalation (LPE) vulnerability.The program exposes a Windows Named Pipe that uses a custom protocol to invoke internal functions. However, this Named Pipe is misconfigured, allowing any authenticated local user to execute arbitrary code with NT AUTHORITY\\SYSTEM privileges and to delete arbitrary files with SYSTEM privileges. By leveraging this, an attacker can execute arbitrary code on the target system with elevated privileges."
}
],
"value": "NitroSense 3.x before 3.01.3052 contains Local Privilege Escalation (LPE) vulnerability.The program exposes a Windows Named Pipe that uses a custom protocol to invoke internal functions. However, this Named Pipe is misconfigured, allowing any authenticated local user to execute arbitrary code with NT AUTHORITY\\SYSTEM privileges and to delete arbitrary files with SYSTEM privileges. By leveraging this, an attacker can execute arbitrary code on the target system with elevated privileges."
}
],
"impacts": [
{
"capecId": "CAPEC-69",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-69 Target Programs with Elevated Privileges"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269: Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-25T01:50:32.063Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19652"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Please update for version\u0026nbsp;\n3.01.3056."
}
],
"value": "Please update for version\u00a0\n3.01.3056."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "NitroSense V3: Local Privilege Escalation (LPE) vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-9489",
"datePublished": "2026-05-25T01:50:32.063Z",
"dateReserved": "2026-05-25T01:34:16.727Z",
"dateUpdated": "2026-05-26T15:20:21.624Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-8069 (GCVE-0-2026-8069)
Vulnerability from nvd – Published: 2026-05-08 05:57 – Updated: 2026-05-08 12:51
VLAI
EPSS
VEX
Title
PredatorSense V3: Local Privilege Escalation (LPE) vulnerability
Summary
PredatorSense version 3.00.3136 to 3.00.3196 contain Local Privilege Escalation (LPE) vulnerability.The program exposes a Windows Named Pipe that uses a custom protocol to invoke internal functions. However, this Named Pipe is misconfigured, allowing any authenticated local user to execute arbitrary code with NT AUTHORITY\SYSTEM privileges and to delete arbitrary files with SYSTEM privileges. By leveraging this, an attacker can execute arbitrary code on the target system with elevated privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-08 12:51 UTC
CWE
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | PredatorSense V3 |
Affected:
3.00.3136 , ≤ 3.00.3196
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-8069",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-08T12:51:31.268398Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-08T12:51:41.992Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "PredatorSense V3",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "3.00.3196",
"status": "affected",
"version": "3.00.3136",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Artem Domarev"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PredatorSense version 3.00.3136 to 3.00.3196 contain Local Privilege Escalation (LPE) vulnerability.The program exposes a Windows Named Pipe that uses a custom protocol to invoke internal functions. However, this Named Pipe is misconfigured, allowing any authenticated local user to execute arbitrary code with NT AUTHORITY\\SYSTEM privileges and to delete arbitrary files with SYSTEM privileges. By leveraging this, an attacker can execute arbitrary code on the target system with elevated privileges."
}
],
"value": "PredatorSense version 3.00.3136 to 3.00.3196 contain Local Privilege Escalation (LPE) vulnerability.The program exposes a Windows Named Pipe that uses a custom protocol to invoke internal functions. However, this Named Pipe is misconfigured, allowing any authenticated local user to execute arbitrary code with NT AUTHORITY\\SYSTEM privileges and to delete arbitrary files with SYSTEM privileges. By leveraging this, an attacker can execute arbitrary code on the target system with elevated privileges."
}
],
"impacts": [
{
"capecId": "CAPEC-69",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-69 Target Programs with Elevated Privileges"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269: Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-08T05:57:22.797Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19652"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update to version\u0026nbsp;3.00.3198."
}
],
"value": "Update to version\u00a03.00.3198."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "PredatorSense V3: Local Privilege Escalation (LPE) vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-8069",
"datePublished": "2026-05-08T05:57:22.797Z",
"dateReserved": "2026-05-07T06:26:33.337Z",
"dateUpdated": "2026-05-08T12:51:41.992Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-25302 (GCVE-0-2019-25302)
Vulnerability from nvd – Published: 2026-02-06 16:41 – Updated: 2026-02-06 20:00
VLAI
EPSS
VEX
Title
Acer Launch Manager 6.1.7600.16385 - 'DsiWMIService' Unquoted Service Path
Summary
Acer Launch Manager 6.1.7600.16385 contains an unquoted service path vulnerability in the DsiWMIService that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\Program Files (x86)\Launch Manager\dsiwmis.exe to insert malicious code that would execute with system-level permissions during service startup.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-06 19:59 UTC
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.exploit-db.com/exploits/47577 | exploit |
| https://www.acer.com/ | product |
| https://www.vulncheck.com/advisories/acer-launch-… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | Launch Manager |
Affected:
6.1.7600.16385
|
Date Public
2019-11-03 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2019-25302",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-06T19:59:54.324307Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-06T20:00:24.847Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Launch Manager",
"vendor": "Acer",
"versions": [
{
"status": "affected",
"version": "6.1.7600.16385"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gustavo Brise\u00f1o"
}
],
"datePublic": "2019-11-03T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Acer Launch Manager 6.1.7600.16385 contains an unquoted service path vulnerability in the DsiWMIService that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\\Program Files (x86)\\Launch Manager\\dsiwmis.exe to insert malicious code that would execute with system-level permissions during service startup."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-06T16:41:37.484Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "ExploitDB-47577",
"tags": [
"exploit"
],
"url": "https://www.exploit-db.com/exploits/47577"
},
{
"name": "Acer Official Website",
"tags": [
"product"
],
"url": "https://www.acer.com/"
},
{
"name": "VulnCheck Advisory: Acer Launch Manager 6.1.7600.16385 - \u0027DsiWMIService\u0027 Unquoted Service Path",
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/acer-launch-manager-dsiwmiservice-unquoted-service-path"
}
],
"title": "Acer Launch Manager 6.1.7600.16385 - \u0027DsiWMIService\u0027 Unquoted Service Path",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2019-25302",
"datePublished": "2026-02-06T16:41:37.484Z",
"dateReserved": "2026-02-06T16:31:11.974Z",
"dateUpdated": "2026-02-06T20:00:24.847Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50610 (GCVE-0-2026-50610)
Vulnerability from cvelistv5 – Published: 2026-09-17 08:26 – Updated: 2026-09-17 12:18
VLAI
EPSS
VEX
Title
Improper Access control Vulnerability in NitroSense and PredatorSense Software
Summary
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications, potentially resulting in local privilege escalation.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 12:16 UTC
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | System Monitoring |
Affected:
* , ≤ 1.0.19.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50610",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T12:16:15.601033Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T12:18:12.672Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "System Monitoring",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.0.19.2",
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Cassius GARAT"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications, potentially resulting in local privilege escalation."
}
],
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications, potentially resulting in local privilege escalation."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233: Privilege Escalation"
}
]
},
{
"capecId": "CAPEC-180",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-180: Exploiting Incorrectly Configured Access Control Security Levels"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T08:26:21.362Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19877"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Update to one of the following versions or later:\n\n * NitroSense v5.2.84\n * PredatorSense v5.2.109"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Improper Access control Vulnerability in NitroSense and PredatorSense Software",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50610",
"datePublished": "2026-09-17T08:26:21.362Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T12:18:12.672Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50609 (GCVE-0-2026-50609)
Vulnerability from cvelistv5 – Published: 2026-09-17 08:21 – Updated: 2026-09-17 12:24
VLAI
EPSS
VEX
Title
Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software
Summary
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 12:23 UTC
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | System Monitoring |
Affected:
* , ≤ 1.0.19.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50609",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T12:23:07.250428Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T12:24:11.273Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "System Monitoring",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.0.19.2",
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Cassius GARAT"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system."
}
],
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system."
}
],
"impacts": [
{
"capecId": "CAPEC-180",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
}
]
},
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T08:21:29.786Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19876"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Update to one of the following versions or later:\n\n * NitroSense v5.2.84\n * PredatorSense v5.2.109"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50609",
"datePublished": "2026-09-17T08:21:29.786Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T12:24:11.273Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50608 (GCVE-0-2026-50608)
Vulnerability from cvelistv5 – Published: 2026-09-17 08:15 – Updated: 2026-09-17 12:25
VLAI
EPSS
VEX
Title
Authentication Vulnerability in NitroSense and PredatorSense Software
Summary
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The WebSocket handshake process does not properly require authentication before allowing connections to the service. Under certain circumstances, unauthorized access to service functionality may be possible.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 12:25 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | System Monitoring |
Affected:
* , ≤ 1.0.19.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50608",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T12:25:32.773472Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T12:25:51.670Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "System Monitoring",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.0.19.2",
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Ayush Choudhary"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The WebSocket handshake process does not properly require authentication before allowing connections to the service. Under certain circumstances, unauthorized access to service functionality may be possible."
}
],
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The WebSocket handshake process does not properly require authentication before allowing connections to the service. Under certain circumstances, unauthorized access to service functionality may be possible."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 1.2,
"baseSeverity": "LOW",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T08:15:17.327Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19875"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Update to one of the following versions or later:\n\n * NitroSense v5.2.84\n * PredatorSense v5.2.109"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authentication Vulnerability in NitroSense and PredatorSense Software",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50608",
"datePublished": "2026-09-17T08:15:17.327Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T12:25:51.670Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50607 (GCVE-0-2026-50607)
Vulnerability from cvelistv5 – Published: 2026-09-17 08:05 – Updated: 2026-09-17 12:26
VLAI
EPSS
VEX
Title
WebSocket Exposure Vulnerability in NitroSense and PredatorSense Software
Summary
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 12:26 UTC
CWE
- CWE-668 - All-Interface Binding
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | System Monitoring |
Affected:
* , ≤ 1.0.19.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50607",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T12:26:05.665465Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T12:26:18.604Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "System Monitoring",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.0.19.2",
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Tolga Cohce"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access."
}
],
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access."
}
],
"impacts": [
{
"capecId": "CAPEC-118",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-118: Collect and Analyze Information"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 2.7,
"baseSeverity": "LOW",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 All-Interface Binding",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T08:22:19.514Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19879"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "WebSocket Exposure Vulnerability in NitroSense and PredatorSense Software",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50607",
"datePublished": "2026-09-17T08:05:44.472Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T12:26:18.604Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50606 (GCVE-0-2026-50606)
Vulnerability from cvelistv5 – Published: 2026-09-17 07:59 – Updated: 2026-09-17 12:30
VLAI
EPSS
VEX
Title
Hard-coded Encryption Key Vulnerability in Acer System Monitoring for NitroSense and PredatorSense Software
Summary
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 12:26 UTC
CWE
- CWE-321 - Hardcoded AES-128-ECB Key
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | System Monitoring |
Affected:
* , ≤ 1.0.19.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50606",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T12:26:30.763323Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T12:30:03.105Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "System Monitoring",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.0.19.2",
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Tolga Cohce"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
}
],
"value": "A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126 Leveraging Hard-coded Credentials"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 1.2,
"baseSeverity": "LOW",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321 Hardcoded AES-128-ECB Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T08:01:19.643Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19873"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Update to one of the following versions or later:\n\n * NitroSense v5.2.84\n * PredatorSense v5.2.109"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Hard-coded Encryption Key Vulnerability in Acer System Monitoring for NitroSense and PredatorSense Software",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50606",
"datePublished": "2026-09-17T07:59:52.258Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T12:30:03.105Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50605 (GCVE-0-2026-50605)
Vulnerability from cvelistv5 – Published: 2026-09-17 07:53 – Updated: 2026-09-17 12:31
VLAI
EPSS
VEX
Title
Privilege Escalation Vulnerability in NitroSense and PredatorSense Software
Summary
A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. Insufficient access controls within a privileged service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 12:31 UTC
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | Agent Serivce |
Affected:
* , ≤ 1.2.110.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50605",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T12:31:23.408055Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T12:31:34.878Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Agent Serivce",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.2.110.2",
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. Insufficient access controls within a privileged service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system."
}
],
"value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. Insufficient access controls within a privileged service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
},
{
"capecId": "CAPEC-180",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T07:53:44.292Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19872"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Update to one of the following versions or later:\n\n * NitroSense v5.2.84\n * PredatorSense v5.2.109"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Privilege Escalation Vulnerability in NitroSense and PredatorSense Software",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50605",
"datePublished": "2026-09-17T07:53:44.292Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T12:31:34.878Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50604 (GCVE-0-2026-50604)
Vulnerability from cvelistv5 – Published: 2026-09-17 04:06 – Updated: 2026-09-17 12:52
VLAI
EPSS
VEX
Title
Unauthenticated Access Vulnerability in NitroSense and PredatorSense Software
Summary
A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The socket handshake process does not properly require authentication before granting access to the service. Under certain circumstances, an unauthorized connection may be established, potentially allowing access to functionality that should be restricted.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 12:52 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | Agent Service |
Affected:
* , ≤ 1.2.110.2
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50604",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T12:52:33.105111Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T12:52:56.787Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Agent Service",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.2.110.2",
"status": "affected",
"version": "*",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Tolga Cohce"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The socket handshake process does not properly require authentication before granting access to the service. Under certain circumstances, an unauthorized connection may be established, potentially allowing access to functionality that should be restricted."
}
],
"value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The socket handshake process does not properly require authentication before granting access to the service. Under certain circumstances, an unauthorized connection may be established, potentially allowing access to functionality that should be restricted."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T07:55:36.264Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19871"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Update to one of the following versions or later:\n\n * NitroSense v5.2.84\n * PredatorSense v5.2.109"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unauthenticated Access Vulnerability in NitroSense and PredatorSense Software",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50604",
"datePublished": "2026-09-17T04:06:40.354Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T12:52:56.787Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50603 (GCVE-0-2026-50603)
Vulnerability from cvelistv5 – Published: 2026-09-17 04:01 – Updated: 2026-09-17 14:48
VLAI
EPSS
VEX
Title
Hard-coded encryption key vulnerability in Acer Agent Service for NitroSense and PredatorSense
Summary
A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-17 14:47 UTC
CWE
- CWE-321 - Hardcoded AES-128-ECB Key
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | Agent Service |
Affected:
* , ≤ 1.2.110.2
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50603",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-17T14:47:57.377766Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T14:48:17.751Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Agent Service",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "1.2.110.2",
"status": "affected",
"version": "*",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Tolga Cohce"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
}
],
"value": "A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to access protected information or perform unauthorized actions."
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126 Leveraging Hard-coded Credentials"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321 Hardcoded AES-128-ECB Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-17T07:54:47.332Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19878"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate to one of the following versions or later:\u003c/p\u003e\u003cul\u003e\u003cli\u003eNitroSense v5.2.84\u003c/li\u003e\u003cli\u003ePredatorSense v5.2.109\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "Update to one of the following versions or later:\n\n * NitroSense v5.2.84\n * PredatorSense v5.2.109"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Hard-coded encryption key vulnerability in Acer Agent Service for NitroSense and PredatorSense",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50603",
"datePublished": "2026-09-17T04:01:12.295Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-09-17T14:48:17.751Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50602 (GCVE-0-2026-50602)
Vulnerability from cvelistv5 – Published: 2026-08-17 02:16 – Updated: 2026-08-17 15:55
VLAI
EPSS
VEX
Title
Planet9 Incorrect Permission Assignment Vulnerability Information
Summary
A security vulnerability has been identified in Planet9 due to incorrect file permissions assigned to an application executable used by the Planet9 background service. The service runs with SYSTEM privileges, while the affected executable grants excessive permissions to non-administrative users. As a result, an authenticated local user could potentially modify or replace the executable and execute arbitrary code with SYSTEM privileges when the service starts or the system is restarted.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-17 15:54 UTC
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | Planet9 background service |
Affected:
NA
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50602",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-17T15:54:48.740071Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T15:55:59.301Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Planet9 background service",
"vendor": "Acer",
"versions": [
{
"status": "affected",
"version": "NA",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Tolga C\u00f6hce"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A security vulnerability has been identified in Planet9 due to incorrect file permissions assigned to an application executable used by the Planet9 background service. The service runs with SYSTEM privileges, while the affected executable grants excessive permissions to non-administrative users. As a result, an authenticated local user could potentially modify or replace the executable and execute arbitrary code with SYSTEM privileges when the service starts or the system is restarted."
}
],
"value": "A security vulnerability has been identified in Planet9 due to incorrect file permissions assigned to an application executable used by the Planet9 background service. The service runs with SYSTEM privileges, while the affected executable grants excessive permissions to non-administrative users. As a result, an authenticated local user could potentially modify or replace the executable and execute arbitrary code with SYSTEM privileges when the service starts or the system is restarted."
}
],
"impacts": [
{
"capecId": "CAPEC-234",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-234 Hijacking a Privileged Process"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T02:16:49.131Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19870"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An update is available that resolves this vulnerability by removing the affected executable files and uninstalling the background service (\u003ccode\u003ePLANET9DAService\u003c/code\u003e). Planet9 will automatically upgrade to the latest version."
}
],
"value": "An update is available that resolves this vulnerability by removing the affected executable files and uninstalling the background service (PLANET9DAService). Planet9 will automatically upgrade to the latest version."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Planet9 Incorrect Permission Assignment Vulnerability Information",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50602",
"datePublished": "2026-08-17T02:16:49.131Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-08-17T15:55:59.301Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-50601 (GCVE-0-2026-50601)
Vulnerability from cvelistv5 – Published: 2026-08-17 02:02 – Updated: 2026-08-17 15:57
VLAI
EPSS
VEX
Title
Planet9 Hardcoded Credentials Vulnerability Information
Summary
A security vulnerability has been identified in the Planet9 desktop application where a hardcoded read-only API key permitted unauthorized access to internal repositories. An attacker could exploit this access to extract embedded administrative keys and secrets, potentially allowing them to gain administrative access to repository infrastructure and modify software source code. To mitigate this security risk, Acer has released an update to resolve the issue.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-17 15:56 UTC
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | Planet9 desktop application |
Affected:
2.6.131 , ≤ 2.8.124
(custom)
|
Date Public
2026-08-17 01:54
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-50601",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-17T15:56:35.523735Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T15:57:28.016Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows",
"64 bit"
],
"product": "Planet9 desktop application",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "2.8.124",
"status": "affected",
"version": "2.6.131",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Ayush Choudhary"
}
],
"datePublic": "2026-08-17T01:54:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A security vulnerability has been identified in the Planet9 desktop application where a hardcoded read-only API key permitted unauthorized access to internal repositories. An attacker could exploit this access to extract embedded administrative keys and secrets, potentially allowing them to gain administrative access to repository infrastructure and modify software source code. To mitigate this security risk, Acer has released an update to resolve the issue."
}
],
"value": "A security vulnerability has been identified in the Planet9 desktop application where a hardcoded read-only API key permitted unauthorized access to internal repositories. An attacker could exploit this access to extract embedded administrative keys and secrets, potentially allowing them to gain administrative access to repository infrastructure and modify software source code. To mitigate this security risk, Acer has released an update to resolve the issue."
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37: Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"exploitMaturity": "UNREPORTED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:U",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-17T02:02:40.508Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19869"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Planet9 Version v2.8.128 contains a resolution to this vulnerability. The application will automatically update to the patched version (v2.8.128) in the background."
}
],
"value": "Planet9 Version v2.8.128 contains a resolution to this vulnerability. The application will automatically update to the patched version (v2.8.128) in the background."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Planet9 Hardcoded Credentials Vulnerability Information",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-50601",
"datePublished": "2026-08-17T02:02:40.508Z",
"dateReserved": "2026-06-05T07:22:32.054Z",
"dateUpdated": "2026-08-17T15:57:28.016Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-9789 (GCVE-0-2026-9789)
Vulnerability from cvelistv5 – Published: 2026-05-28 02:39 – Updated: 2026-05-28 13:12
VLAI
EPSS
VEX
Title
NitroSense V3: Security Vulnerability Information
Summary
A Local Privilege Escalation (LPE) vulnerability affects Acer NitroSense software versions prior to 3.01.3052. The vulnerability stems from the the PSAdminAgent service, which creates a Named Pipe with a weak Access Control List (ACL). This allows any authenticated local user to connect and send commands. Because the service does not check the caller's privileges before running file deletion commands, a low-privileged local user can exploit this to delete arbitrary files with system authority.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-28 13:11 UTC
CWE
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | NitrorSense V3 |
Affected:
3.01.3001 , ≤ 3.01.3052
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9789",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-28T13:11:55.727489Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T13:12:02.598Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "NitrorSense V3",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "3.01.3052",
"status": "affected",
"version": "3.01.3001",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Vo Duc Thang"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A Local Privilege Escalation (LPE) vulnerability affects Acer NitroSense software versions prior to 3.01.3052. The vulnerability stems from the the PSAdminAgent service, which creates a Named Pipe with a weak Access Control List (ACL). This allows any authenticated local user to connect and send commands. Because the service does not check the caller\u0027s privileges before running file deletion commands, a low-privileged local user can exploit this to delete arbitrary files with system authority."
}
],
"value": "A Local Privilege Escalation (LPE) vulnerability affects Acer NitroSense software versions prior to 3.01.3052. The vulnerability stems from the the PSAdminAgent service, which creates a Named Pipe with a weak Access Control List (ACL). This allows any authenticated local user to connect and send commands. Because the service does not check the caller\u0027s privileges before running file deletion commands, a low-privileged local user can exploit this to delete arbitrary files with system authority."
}
],
"impacts": [
{
"capecId": "CAPEC-69",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-69 Target Programs with Elevated Privileges"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269: Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-28T02:39:40.930Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19670"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This issue is resolved in NitroSense versions V3.01.3056."
}
],
"value": "This issue is resolved in NitroSense versions V3.01.3056."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "NitroSense V3: Security Vulnerability Information",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-9789",
"datePublished": "2026-05-28T02:39:40.930Z",
"dateReserved": "2026-05-28T02:16:31.420Z",
"dateUpdated": "2026-05-28T13:12:02.598Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-9490 (GCVE-0-2026-9490)
Vulnerability from cvelistv5 – Published: 2026-05-25 07:25 – Updated: 2026-05-26 14:43
VLAI
EPSS
VEX
Title
Acer Care Center creates a Named Pipe with a weak Security Descriptor
Summary
A security vulnerability has been identified in Acer Care Center where the ACCSvc service creates a Named Pipe with a weak Security Descriptor. This vulnerability allows an authenticated local user to connect and send a specially crafted message (message type 0x03) to the pipe, causing the service to crash with exit code 1067 (ERROR_PROCESS_ABORTED). To mitigate this potential local service disruption, Acer requires users to update the software to the latest version.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-26 14:37 UTC
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | Care Center |
Affected:
4.0 , ≤ 4.00.3058
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9490",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T14:37:24.296733Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T14:43:23.306Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Care Center",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "4.00.3058",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Vo Duc Thang"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A security vulnerability has been identified in Acer Care Center where the ACCSvc service creates a Named Pipe with a weak Security Descriptor. This vulnerability allows an authenticated local user to connect and send a specially crafted message (message type 0x03) to the pipe, causing the service to crash with exit code 1067 (ERROR_PROCESS_ABORTED). To mitigate this potential local service disruption, Acer requires users to update the software to the latest version."
}
],
"value": "A security vulnerability has been identified in Acer Care Center where the ACCSvc service creates a Named Pipe with a weak Security Descriptor. This vulnerability allows an authenticated local user to connect and send a specially crafted message (message type 0x03) to the pipe, causing the service to crash with exit code 1067 (ERROR_PROCESS_ABORTED). To mitigate this potential local service disruption, Acer requires users to update the software to the latest version."
}
],
"impacts": [
{
"capecId": "CAPEC-610",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-610: Inter-Process Communication (IPC) Misconfiguration"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/RE:M",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-25T07:25:02.310Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19668"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Please update to v4.00.3060."
}
],
"value": "Please update to v4.00.3060."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Acer Care Center creates a Named Pipe with a weak Security Descriptor",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-9490",
"datePublished": "2026-05-25T07:25:02.310Z",
"dateReserved": "2026-05-25T01:34:19.934Z",
"dateUpdated": "2026-05-26T14:43:23.306Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-9489 (GCVE-0-2026-9489)
Vulnerability from cvelistv5 – Published: 2026-05-25 01:50 – Updated: 2026-05-26 15:20
VLAI
EPSS
VEX
Title
NitroSense V3: Local Privilege Escalation (LPE) vulnerability
Summary
NitroSense 3.x before 3.01.3052 contains Local Privilege Escalation (LPE) vulnerability.The program exposes a Windows Named Pipe that uses a custom protocol to invoke internal functions. However, this Named Pipe is misconfigured, allowing any authenticated local user to execute arbitrary code with NT AUTHORITY\SYSTEM privileges and to delete arbitrary files with SYSTEM privileges. By leveraging this, an attacker can execute arbitrary code on the target system with elevated privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-26 15:11 UTC
CWE
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | NitrorSense V3 |
Affected:
3.01.3001 , ≤ 3.01.3052
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9489",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T15:11:04.376350Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T15:20:21.624Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "NitrorSense V3",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "3.01.3052",
"status": "affected",
"version": "3.01.3001",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Artem Domarev"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "NitroSense 3.x before 3.01.3052 contains Local Privilege Escalation (LPE) vulnerability.The program exposes a Windows Named Pipe that uses a custom protocol to invoke internal functions. However, this Named Pipe is misconfigured, allowing any authenticated local user to execute arbitrary code with NT AUTHORITY\\SYSTEM privileges and to delete arbitrary files with SYSTEM privileges. By leveraging this, an attacker can execute arbitrary code on the target system with elevated privileges."
}
],
"value": "NitroSense 3.x before 3.01.3052 contains Local Privilege Escalation (LPE) vulnerability.The program exposes a Windows Named Pipe that uses a custom protocol to invoke internal functions. However, this Named Pipe is misconfigured, allowing any authenticated local user to execute arbitrary code with NT AUTHORITY\\SYSTEM privileges and to delete arbitrary files with SYSTEM privileges. By leveraging this, an attacker can execute arbitrary code on the target system with elevated privileges."
}
],
"impacts": [
{
"capecId": "CAPEC-69",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-69 Target Programs with Elevated Privileges"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269: Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-25T01:50:32.063Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19652"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Please update for version\u0026nbsp;\n3.01.3056."
}
],
"value": "Please update for version\u00a0\n3.01.3056."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "NitroSense V3: Local Privilege Escalation (LPE) vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-9489",
"datePublished": "2026-05-25T01:50:32.063Z",
"dateReserved": "2026-05-25T01:34:16.727Z",
"dateUpdated": "2026-05-26T15:20:21.624Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-8069 (GCVE-0-2026-8069)
Vulnerability from cvelistv5 – Published: 2026-05-08 05:57 – Updated: 2026-05-08 12:51
VLAI
EPSS
VEX
Title
PredatorSense V3: Local Privilege Escalation (LPE) vulnerability
Summary
PredatorSense version 3.00.3136 to 3.00.3196 contain Local Privilege Escalation (LPE) vulnerability.The program exposes a Windows Named Pipe that uses a custom protocol to invoke internal functions. However, this Named Pipe is misconfigured, allowing any authenticated local user to execute arbitrary code with NT AUTHORITY\SYSTEM privileges and to delete arbitrary files with SYSTEM privileges. By leveraging this, an attacker can execute arbitrary code on the target system with elevated privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-08 12:51 UTC
CWE
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | PredatorSense V3 |
Affected:
3.00.3136 , ≤ 3.00.3196
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-8069",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-08T12:51:31.268398Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-08T12:51:41.992Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "PredatorSense V3",
"vendor": "Acer",
"versions": [
{
"lessThanOrEqual": "3.00.3196",
"status": "affected",
"version": "3.00.3136",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Artem Domarev"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PredatorSense version 3.00.3136 to 3.00.3196 contain Local Privilege Escalation (LPE) vulnerability.The program exposes a Windows Named Pipe that uses a custom protocol to invoke internal functions. However, this Named Pipe is misconfigured, allowing any authenticated local user to execute arbitrary code with NT AUTHORITY\\SYSTEM privileges and to delete arbitrary files with SYSTEM privileges. By leveraging this, an attacker can execute arbitrary code on the target system with elevated privileges."
}
],
"value": "PredatorSense version 3.00.3136 to 3.00.3196 contain Local Privilege Escalation (LPE) vulnerability.The program exposes a Windows Named Pipe that uses a custom protocol to invoke internal functions. However, this Named Pipe is misconfigured, allowing any authenticated local user to execute arbitrary code with NT AUTHORITY\\SYSTEM privileges and to delete arbitrary files with SYSTEM privileges. By leveraging this, an attacker can execute arbitrary code on the target system with elevated privileges."
}
],
"impacts": [
{
"capecId": "CAPEC-69",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-69 Target Programs with Elevated Privileges"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269: Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-08T05:57:22.797Z",
"orgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"shortName": "Acer"
},
"references": [
{
"url": "https://community.acer.com/en/kb/articles/19652"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update to version\u0026nbsp;3.00.3198."
}
],
"value": "Update to version\u00a03.00.3198."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "PredatorSense V3: Local Privilege Escalation (LPE) vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "8fc372e3-d9c5-46e4-9410-38469745c639",
"assignerShortName": "Acer",
"cveId": "CVE-2026-8069",
"datePublished": "2026-05-08T05:57:22.797Z",
"dateReserved": "2026-05-07T06:26:33.337Z",
"dateUpdated": "2026-05-08T12:51:41.992Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-25302 (GCVE-0-2019-25302)
Vulnerability from cvelistv5 – Published: 2026-02-06 16:41 – Updated: 2026-02-06 20:00
VLAI
EPSS
VEX
Title
Acer Launch Manager 6.1.7600.16385 - 'DsiWMIService' Unquoted Service Path
Summary
Acer Launch Manager 6.1.7600.16385 contains an unquoted service path vulnerability in the DsiWMIService that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\Program Files (x86)\Launch Manager\dsiwmis.exe to insert malicious code that would execute with system-level permissions during service startup.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-06 19:59 UTC
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.exploit-db.com/exploits/47577 | exploit |
| https://www.acer.com/ | product |
| https://www.vulncheck.com/advisories/acer-launch-… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Acer | Launch Manager |
Affected:
6.1.7600.16385
|
Date Public
2019-11-03 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2019-25302",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-06T19:59:54.324307Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-06T20:00:24.847Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Launch Manager",
"vendor": "Acer",
"versions": [
{
"status": "affected",
"version": "6.1.7600.16385"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gustavo Brise\u00f1o"
}
],
"datePublic": "2019-11-03T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Acer Launch Manager 6.1.7600.16385 contains an unquoted service path vulnerability in the DsiWMIService that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\\Program Files (x86)\\Launch Manager\\dsiwmis.exe to insert malicious code that would execute with system-level permissions during service startup."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-06T16:41:37.484Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "ExploitDB-47577",
"tags": [
"exploit"
],
"url": "https://www.exploit-db.com/exploits/47577"
},
{
"name": "Acer Official Website",
"tags": [
"product"
],
"url": "https://www.acer.com/"
},
{
"name": "VulnCheck Advisory: Acer Launch Manager 6.1.7600.16385 - \u0027DsiWMIService\u0027 Unquoted Service Path",
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/acer-launch-manager-dsiwmiservice-unquoted-service-path"
}
],
"title": "Acer Launch Manager 6.1.7600.16385 - \u0027DsiWMIService\u0027 Unquoted Service Path",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2019-25302",
"datePublished": "2026-02-06T16:41:37.484Z",
"dateReserved": "2026-02-06T16:31:11.974Z",
"dateUpdated": "2026-02-06T20:00:24.847Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}