CVE-2021-46304
Vulnerability from cvelistv5
Published
2022-08-10 11:17
Modified
2024-08-04 05:02
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions), CP-8021 MASTER MODULE (All versions), CP-8022 MASTER MODULE WITH GPRS (All versions). The component allows to activate a web server module which provides unauthenticated access to its web pages. This could allow an attacker to retrieve debug-level information from the component such as internal network topology or connected systems.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | CP-8000 MASTER MODULE WITH I/O -25/+70°C |
Version: All versions |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T05:02:11.304Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185638.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "CP-8021 MASTER MODULE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "CP-8022 MASTER MODULE WITH GPRS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C (All versions), CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C (All versions), CP-8021 MASTER MODULE (All versions), CP-8022 MASTER MODULE WITH GPRS (All versions). The component allows to activate a web server module which provides unauthenticated access to its web pages. This could allow an attacker to retrieve debug-level information from the component such as internal network topology or connected systems." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284: Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:17:23", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185638.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-46304", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "CP-8021 MASTER MODULE", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "CP-8022 MASTER MODULE WITH GPRS", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C (All versions), CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C (All versions), CP-8021 MASTER MODULE (All versions), CP-8022 MASTER MODULE WITH GPRS (All versions). The component allows to activate a web server module which provides unauthenticated access to its web pages. This could allow an attacker to retrieve debug-level information from the component such as internal network topology or connected systems." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-284: Improper Access Control" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-185638.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185638.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-46304", "datePublished": "2022-08-10T11:17:23", "dateReserved": "2022-01-14T00:00:00", "dateUpdated": "2024-08-04T05:02:11.304Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-46304\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-08-10T12:15:11.567\",\"lastModified\":\"2024-11-21T06:33:50.907\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C (All versions), CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C (All versions), CP-8021 MASTER MODULE (All versions), CP-8022 MASTER MODULE WITH GPRS (All versions). The component allows to activate a web server module which provides unauthenticated access to its web pages. This could allow an attacker to retrieve debug-level information from the component such as internal network topology or connected systems.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en el M\u00d3DULO MASTER CP-8000 CON E/S -25/+70\u00b0C (Todas las versiones), M\u00d3DULO MASTER CP-8000 CON E/S -40/+70\u00b0C (Todas las versiones), M\u00d3DULO MASTER CP-8021 (Todas las versiones), M\u00d3DULO MASTER CP-8022 CON GPRS (Todas las versiones). El componente permite activar un m\u00f3dulo de servidor web que proporciona acceso no autenticado a sus p\u00e1ginas web. Esto podr\u00eda permitir a un atacante recuperar informaci\u00f3n a nivel de depuraci\u00f3n del componente, como la topolog\u00eda de la red interna o los sistemas conectados\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:cp-8021_master_module_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FE530A72-33F3-48B5-8F10-1B093762C8AE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:cp-8021_master_module:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0F257456-CB80-485A-94B7-B996D388D38D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:cp-8000_master_module_with_i\\\\/o_-25\\\\/\\\\+70_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8EFF2EB1-B4D1-4A81-8453-BCAA221E693A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:cp-8000_master_module_with_i\\\\/o_-25\\\\/\\\\+70:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5BC48F66-67A4-4788-B9AC-8C1E682375DF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:cp-8000_master_module_with_i\\\\/o_-40\\\\/\\\\+70_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"78987EEB-1919-4E9F-A011-364B6D815C2D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:cp-8000_master_module_with_i\\\\/o_-40\\\\/\\\\+70:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"218B8555-E36A-4149-91D4-CF56DE6EFD4C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:cp-8022_master_module_with_gprs_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"88907B10-5555-465C-A048-791E80EC2F35\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:cp-8022_master_module_with_gprs:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6807A5B6-F103-460A-83FD-7D7C7AA25D71\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-185638.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-185638.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.