fkie_cve-2021-46304
Vulnerability from fkie_nvd
Published
2022-08-10 12:15
Modified
2024-11-21 06:33
Severity ?
Summary
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions), CP-8021 MASTER MODULE (All versions), CP-8022 MASTER MODULE WITH GPRS (All versions). The component allows to activate a web server module which provides unauthenticated access to its web pages. This could allow an attacker to retrieve debug-level information from the component such as internal network topology or connected systems.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:cp-8021_master_module_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE530A72-33F3-48B5-8F10-1B093762C8AE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:cp-8021_master_module:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F257456-CB80-485A-94B7-B996D388D38D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:cp-8000_master_module_with_i\\/o_-25\\/\\+70_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8EFF2EB1-B4D1-4A81-8453-BCAA221E693A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:cp-8000_master_module_with_i\\/o_-25\\/\\+70:-:*:*:*:*:*:*:*", "matchCriteriaId": "5BC48F66-67A4-4788-B9AC-8C1E682375DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:cp-8000_master_module_with_i\\/o_-40\\/\\+70_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "78987EEB-1919-4E9F-A011-364B6D815C2D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:cp-8000_master_module_with_i\\/o_-40\\/\\+70:-:*:*:*:*:*:*:*", "matchCriteriaId": "218B8555-E36A-4149-91D4-CF56DE6EFD4C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:cp-8022_master_module_with_gprs_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "88907B10-5555-465C-A048-791E80EC2F35", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:cp-8022_master_module_with_gprs:-:*:*:*:*:*:*:*", "matchCriteriaId": "6807A5B6-F103-460A-83FD-7D7C7AA25D71", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C (All versions), CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C (All versions), CP-8021 MASTER MODULE (All versions), CP-8022 MASTER MODULE WITH GPRS (All versions). The component allows to activate a web server module which provides unauthenticated access to its web pages. This could allow an attacker to retrieve debug-level information from the component such as internal network topology or connected systems." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en el M\u00d3DULO MASTER CP-8000 CON E/S -25/+70\u00b0C (Todas las versiones), M\u00d3DULO MASTER CP-8000 CON E/S -40/+70\u00b0C (Todas las versiones), M\u00d3DULO MASTER CP-8021 (Todas las versiones), M\u00d3DULO MASTER CP-8022 CON GPRS (Todas las versiones). El componente permite activar un m\u00f3dulo de servidor web que proporciona acceso no autenticado a sus p\u00e1ginas web. Esto podr\u00eda permitir a un atacante recuperar informaci\u00f3n a nivel de depuraci\u00f3n del componente, como la topolog\u00eda de la red interna o los sistemas conectados" } ], "id": "CVE-2021-46304", "lastModified": "2024-11-21T06:33:50.907", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-08-10T12:15:11.567", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185638.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185638.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-284" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.