CVE-2026-49499 (GCVE-0-2026-49499)
Vulnerability from nvd – Published: 2026-07-22 15:39 – Updated: 2026-07-24 03:56
VLAI
EPSS
VEX
Summary
Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) a Generation of Incorrect Security Tokens vulnerability in the IAM. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-1270 - Generation of Incorrect Security Tokens
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048884… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Manager |
Affected:
0 , < 20.2.0.0 or later
(semver)
|
Date Public
2026-07-14 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-49499",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-23T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T03:56:08.365Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "20.2.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-14T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) a Generation of Incorrect Security Tokens vulnerability in the IAM. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) a Generation of Incorrect Security Tokens vulnerability in the IAM. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1270",
"description": "CWE-1270: Generation of Incorrect Security Tokens",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-22T15:39:48.244Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-49499",
"datePublished": "2026-07-22T15:39:48.244Z",
"dateReserved": "2026-05-31T17:04:24.517Z",
"dateUpdated": "2026-07-24T03:56:08.365Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46738 (GCVE-0-2026-46738)
Vulnerability from nvd – Published: 2026-07-22 15:34 – Updated: 2026-07-24 03:56
VLAI
EPSS
VEX
Summary
Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048884… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Manager |
Affected:
0 , < 20.2.0.0 or later
(semver)
|
Date Public
2026-07-14 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-46738",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-23T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T03:56:07.554Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "20.2.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank WinD39 - Huynh Dinh Vu and Haxship1337 - Huynh Dinh Van for reporting this issue."
}
],
"datePublic": "2026-07-14T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-22T15:34:12.800Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46738",
"datePublished": "2026-07-22T15:34:12.800Z",
"dateReserved": "2026-05-17T17:04:27.066Z",
"dateUpdated": "2026-07-24T03:56:07.554Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46737 (GCVE-0-2026-46737)
Vulnerability from nvd – Published: 2026-07-22 15:49 – Updated: 2026-07-24 20:12
VLAI
EPSS
VEX
Summary
Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Remote execution.
Severity
6.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048884… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Manager |
Affected:
0 , < 20.2.0.0 or later
(semver)
|
Date Public
2026-07-14 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-46737",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-24T03:56:09.645163Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T20:12:11.641Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "20.2.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank WinD39 - Huynh Dinh Vu for reporting this issue."
}
],
"datePublic": "2026-07-14T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Remote execution."
}
],
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Remote execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-22T15:49:40.557Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46737",
"datePublished": "2026-07-22T15:49:40.557Z",
"dateReserved": "2026-05-17T17:04:27.066Z",
"dateUpdated": "2026-07-24T20:12:11.641Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-44276 (GCVE-0-2026-44276)
Vulnerability from nvd – Published: 2026-07-22 15:13 – Updated: 2026-07-22 15:55
VLAI
EPSS
VEX
Summary
Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the REST API. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure.
Severity
6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048884… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Manager |
Affected:
0 , < 20.2.0.0 or later
(semver)
|
Date Public
2026-07-14 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-44276",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-22T15:54:59.985096Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-22T15:55:09.983Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "20.2.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank shauntp for reporting this issue."
}
],
"datePublic": "2026-07-14T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the REST API. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure."
}
],
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the REST API. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-22T15:13:07.215Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-44276",
"datePublished": "2026-07-22T15:13:07.215Z",
"dateReserved": "2026-05-05T17:04:45.714Z",
"dateUpdated": "2026-07-22T15:55:09.983Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-40714 (GCVE-0-2026-40714)
Vulnerability from nvd – Published: 2026-07-22 15:20 – Updated: 2026-07-24 03:56
VLAI
EPSS
VEX
Summary
Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
Severity
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048884… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Manager |
Affected:
0 , < 20.2.0.0 or later
(semver)
|
Date Public
2026-07-14 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40714",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-23T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T03:56:05.881Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "20.2.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank WinD39 - Huynh Dinh Vu for reporting this issue."
}
],
"datePublic": "2026-07-14T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-22T15:20:35.358Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-40714",
"datePublished": "2026-07-22T15:20:35.358Z",
"dateReserved": "2026-04-15T05:04:31.837Z",
"dateUpdated": "2026-07-24T03:56:05.881Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-40712 (GCVE-0-2026-40712)
Vulnerability from nvd – Published: 2026-07-22 15:28 – Updated: 2026-07-24 03:56
VLAI
EPSS
VEX
Summary
Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048884… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Manager |
Affected:
0 , < 20.2.0.0 or later
(semver)
|
Date Public
2026-07-14 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40712",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-23T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T03:56:06.739Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "20.2.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank WinD39 - Huynh Dinh Vu and Haxship1337 - Huynh Dinh Van for reporting this issue."
}
],
"datePublic": "2026-07-14T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-22T15:28:15.113Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-40712",
"datePublished": "2026-07-22T15:28:15.113Z",
"dateReserved": "2026-04-15T05:04:31.837Z",
"dateUpdated": "2026-07-24T03:56:06.739Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-56687 (GCVE-0-2026-56687)
Vulnerability from nvd – Published: 2026-07-15 17:33 – Updated: 2026-07-16 03:55
VLAI
EPSS
VEX
Summary
Dell ThinOS 10, versions prior to 2605_10.2100, contain an Obsolete Feature in UI vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-448 - Obsolete Feature in UI
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048964… | vendor-advisory |
Impacted products
Date Public
2026-07-15 17:31
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-56687",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-16T03:55:52.361Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ThinOS 10",
"vendor": "Dell",
"versions": [
{
"lessThan": "2605_10.2100",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-15T17:31:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell ThinOS 10, versions prior to 2605_10.2100, contain an Obsolete Feature in UI vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"value": "Dell ThinOS 10, versions prior to 2605_10.2100, contain an Obsolete Feature in UI vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-448",
"description": "CWE-448: Obsolete Feature in UI",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T17:33:07.011Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000489640/dsa-2026-300-security-update-for-dell-thinos-10-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-56687",
"datePublished": "2026-07-15T17:33:07.011Z",
"dateReserved": "2026-06-22T17:04:26.238Z",
"dateUpdated": "2026-07-16T03:55:52.361Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-56087 (GCVE-0-2026-56087)
Vulnerability from nvd – Published: 2026-07-15 17:28 – Updated: 2026-07-15 19:30
VLAI
EPSS
VEX
Summary
Dell ThinOS 10, versions prior to 2605_10.2100 contain a Protection Mechanism Failure vulnerability. An attacker with physical access could potentially exploit this vulnerability, leading to unauthorized access to encrypted data.
Severity
6.1 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-693 - Protection Mechanism Failure
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048964… | vendor-advisory |
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-56087",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T19:30:30.327093Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T19:30:38.769Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ThinOS 10",
"vendor": "Dell",
"versions": [
{
"lessThan": "2605_10.2100",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell Technologies would like to thank Darren McDonald at AmberWolf for reporting this issue"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell ThinOS 10, versions prior to 2605_10.2100 contain a Protection Mechanism Failure vulnerability. An attacker with physical access could potentially exploit this vulnerability, leading to unauthorized access to encrypted data."
}
],
"value": "Dell ThinOS 10, versions prior to 2605_10.2100 contain a Protection Mechanism Failure vulnerability. An attacker with physical access could potentially exploit this vulnerability, leading to unauthorized access to encrypted data."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-693",
"description": "CWE-693: Protection Mechanism Failure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T17:28:03.944Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000489640/dsa-2026-300-security-update-for-dell-thinos-10-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-56087",
"datePublished": "2026-07-15T17:28:03.944Z",
"dateReserved": "2026-06-18T17:04:56.016Z",
"dateUpdated": "2026-07-15T19:30:38.769Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-40633 (GCVE-0-2026-40633)
Vulnerability from nvd – Published: 2026-07-15 10:07 – Updated: 2026-07-15 15:11
VLAI
EPSS
VEX
Summary
Dell PowerScale OneFS versions 9.5.0.0 through 9.10.1.7, versions 9.11.0.0 through 9.13.0.2 contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048360… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale OneFS |
Affected:
0 , < 9.10.1.8 or later
(semver)
Affected: 0 , < 9.13.1.0 or later (semver) |
Date Public
2026-06-30 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40633",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T13:42:56.612736Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T15:11:44.976Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale OneFS",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.10.1.8 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "9.13.1.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-06-30T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale OneFS versions 9.5.0.0 through 9.10.1.7, versions 9.11.0.0 through 9.13.0.2 contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell PowerScale OneFS versions 9.5.0.0 through 9.10.1.7, versions 9.11.0.0 through 9.13.0.2 contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T10:07:27.568Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000483600/dsa-2026-261-security-update-for-dell-powerscale-onefs-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-40633",
"datePublished": "2026-07-15T10:07:27.568Z",
"dateReserved": "2026-04-14T16:10:47.674Z",
"dateUpdated": "2026-07-15T15:11:44.976Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-49501 (GCVE-0-2026-49501)
Vulnerability from nvd – Published: 2026-07-15 10:01 – Updated: 2026-07-16 03:55
VLAI
EPSS
VEX
Summary
Dell PowerScale OneFS versions 9.5.0.0 through 9.10.1.7, and versions 9.11.0.0 through 9.13.0.2 contains an Improper Privilege Management vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.
Severity
6.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048360… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale OneFS |
Affected:
0 , < 9.10.1.8 or later
(semver)
Affected: 0 , < 9.13.1.0 or later (semver) |
Date Public
2026-06-30 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-49501",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-16T03:55:21.048Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale OneFS",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.10.1.8 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "9.13.1.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-06-30T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale OneFS versions 9.5.0.0 through 9.10.1.7, and versions 9.11.0.0 through 9.13.0.2 contains an Improper Privilege Management vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell PowerScale OneFS versions 9.5.0.0 through 9.10.1.7, and versions 9.11.0.0 through 9.13.0.2 contains an Improper Privilege Management vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269: Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T10:01:11.925Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000483600/dsa-2026-261-security-update-for-dell-powerscale-onefs-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-49501",
"datePublished": "2026-07-15T10:01:11.925Z",
"dateReserved": "2026-05-31T17:04:24.517Z",
"dateUpdated": "2026-07-16T03:55:21.048Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-54470 (GCVE-0-2026-54470)
Vulnerability from nvd – Published: 2026-07-10 12:20 – Updated: 2026-07-10 14:43
VLAI
EPSS
VEX
Summary
Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access.
Severity
5.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-611 - Improper Restriction of XML External Entity Reference
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048354… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Unisphere for PowerMax |
Affected:
0 , < 10.3.0.7 or later
(semver)
Affected: 0 , < 10.3.1.1 Patch 11360 or later (semver) |
Date Public
2026-07-09 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-54470",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-10T14:42:54.892451Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T14:43:05.838Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax",
"vendor": "Dell",
"versions": [
{
"lessThan": "10.3.0.7 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "10.3.1.1 Patch 11360 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-09T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"value": "Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-611",
"description": "CWE-611: Improper Restriction of XML External Entity Reference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T12:20:16.742Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000483543/dsa-2026-272-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtualappliance-dell-unisphere-360-dell-solutionsenabler-and-dell-solutionsenabler-virtualappliance-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-54470",
"datePublished": "2026-07-10T12:20:16.742Z",
"dateReserved": "2026-06-15T16:28:29.012Z",
"dateUpdated": "2026-07-10T14:43:05.838Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-54469 (GCVE-0-2026-54469)
Vulnerability from nvd – Published: 2026-07-10 12:14 – Updated: 2026-07-14 03:55
VLAI
EPSS
VEX
Summary
Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior, contain(s) a Deserialization of Untrusted Data vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048354… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Unisphere for PowerMax |
Affected:
0 , < 10.3.0.7 or later
(semver)
Affected: 0 , < 10.3.1.1 Patch 11360 or later (semver) |
Date Public
2026-07-09 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-54469",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-13T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T03:55:41.008Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax",
"vendor": "Dell",
"versions": [
{
"lessThan": "10.3.0.7 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "10.3.1.1 Patch 11360 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-09T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior, contain(s) a Deserialization of Untrusted Data vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges."
}
],
"value": "Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior, contain(s) a Deserialization of Untrusted Data vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T12:14:48.803Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000483543/dsa-2026-272-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtualappliance-dell-unisphere-360-dell-solutionsenabler-and-dell-solutionsenabler-virtualappliance-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-54469",
"datePublished": "2026-07-10T12:14:48.803Z",
"dateReserved": "2026-06-15T16:28:29.012Z",
"dateUpdated": "2026-07-14T03:55:41.008Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-56690 (GCVE-0-2026-56690)
Vulnerability from nvd – Published: 2026-07-10 11:43 – Updated: 2026-07-10 13:14
VLAI
EPSS
VEX
Summary
Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure, Information exposure, and Unauthorized access.
Severity
8.5 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00047753… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerFlex Manager |
Affected:
0 , < 5.1.0.1 or later
(semver)
Affected: 0 , < 4.5.5.2 or later (semver) |
Date Public
2026-07-06 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-56690",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-10T13:14:21.210025Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T13:14:31.666Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerFlex Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "5.1.0.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "4.5.5.2 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-06T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure, Information exposure, and Unauthorized access."
}
],
"value": "Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure, Information exposure, and Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T11:43:44.004Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000477538/dsa-2026-066-security-update-for-powerflex-software-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-56690",
"datePublished": "2026-07-10T11:43:44.004Z",
"dateReserved": "2026-06-22T17:04:26.238Z",
"dateUpdated": "2026-07-10T13:14:31.666Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-56689 (GCVE-0-2026-56689)
Vulnerability from nvd – Published: 2026-07-10 11:51 – Updated: 2026-07-10 13:00
VLAI
EPSS
VEX
Summary
Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure.
Severity
7.7 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00047753… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerFlex Manager |
Affected:
0 , < 5.1.0.1 or later
(semver)
Affected: 0 , < 4.5.5.2 or later (semver) |
Date Public
2026-07-06 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-56689",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-10T12:59:59.557962Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T13:00:10.810Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerFlex Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "5.1.0.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "4.5.5.2 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-06T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure."
}
],
"value": "Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T11:51:27.171Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000477538/dsa-2026-066-security-update-for-powerflex-software-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-56689",
"datePublished": "2026-07-10T11:51:27.171Z",
"dateReserved": "2026-06-22T17:04:26.238Z",
"dateUpdated": "2026-07-10T13:00:10.810Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-56688 (GCVE-0-2026-56688)
Vulnerability from nvd – Published: 2026-07-10 11:57 – Updated: 2026-07-10 17:01
VLAI
EPSS
VEX
Summary
Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00047753… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerFlex Manager |
Affected:
0 , < 5.1.0.1 or later
(semver)
Affected: 0 , < 4.5.5.2 or later (semver) |
Date Public
2026-07-06 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-56688",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-10T16:49:45.463721Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T17:01:12.022Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerFlex Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "5.1.0.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "4.5.5.2 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-06T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure."
}
],
"value": "Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T11:57:41.752Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000477538/dsa-2026-066-security-update-for-powerflex-software-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-56688",
"datePublished": "2026-07-10T11:57:41.752Z",
"dateReserved": "2026-06-22T17:04:26.238Z",
"dateUpdated": "2026-07-10T17:01:12.022Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-54468 (GCVE-0-2026-54468)
Vulnerability from nvd – Published: 2026-07-10 12:09 – Updated: 2026-07-10 18:53
VLAI
EPSS
VEX
Summary
Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior, contain(s) a path traversal vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048354… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Unisphere for PowerMax |
Affected:
0 , < 10.3.0.7 or later
(semver)
Affected: 0 , < 10.3.1.1 Patch 11360 or later (semver) |
Date Public
2026-07-09 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-54468",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-10T18:52:53.950887Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T18:53:01.001Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax",
"vendor": "Dell",
"versions": [
{
"lessThan": "10.3.0.7 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "10.3.1.1 Patch 11360 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-09T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior, contain(s) a path traversal vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files."
}
],
"value": "Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior, contain(s) a path traversal vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T12:09:05.546Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000483543/dsa-2026-272-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtualappliance-dell-unisphere-360-dell-solutionsenabler-and-dell-solutionsenabler-virtualappliance-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-54468",
"datePublished": "2026-07-10T12:09:05.546Z",
"dateReserved": "2026-06-15T16:28:29.012Z",
"dateUpdated": "2026-07-10T18:53:01.001Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46737 (GCVE-0-2026-46737)
Vulnerability from cvelistv5 – Published: 2026-07-22 15:49 – Updated: 2026-07-24 20:12
VLAI
EPSS
VEX
Summary
Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Remote execution.
Severity
6.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048884… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Manager |
Affected:
0 , < 20.2.0.0 or later
(semver)
|
Date Public
2026-07-14 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-46737",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-24T03:56:09.645163Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T20:12:11.641Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "20.2.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank WinD39 - Huynh Dinh Vu for reporting this issue."
}
],
"datePublic": "2026-07-14T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Remote execution."
}
],
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Remote execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-22T15:49:40.557Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46737",
"datePublished": "2026-07-22T15:49:40.557Z",
"dateReserved": "2026-05-17T17:04:27.066Z",
"dateUpdated": "2026-07-24T20:12:11.641Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-49499 (GCVE-0-2026-49499)
Vulnerability from cvelistv5 – Published: 2026-07-22 15:39 – Updated: 2026-07-24 03:56
VLAI
EPSS
VEX
Summary
Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) a Generation of Incorrect Security Tokens vulnerability in the IAM. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-1270 - Generation of Incorrect Security Tokens
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048884… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Manager |
Affected:
0 , < 20.2.0.0 or later
(semver)
|
Date Public
2026-07-14 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-49499",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-23T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T03:56:08.365Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "20.2.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-14T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) a Generation of Incorrect Security Tokens vulnerability in the IAM. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) a Generation of Incorrect Security Tokens vulnerability in the IAM. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1270",
"description": "CWE-1270: Generation of Incorrect Security Tokens",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-22T15:39:48.244Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-49499",
"datePublished": "2026-07-22T15:39:48.244Z",
"dateReserved": "2026-05-31T17:04:24.517Z",
"dateUpdated": "2026-07-24T03:56:08.365Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-46738 (GCVE-0-2026-46738)
Vulnerability from cvelistv5 – Published: 2026-07-22 15:34 – Updated: 2026-07-24 03:56
VLAI
EPSS
VEX
Summary
Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048884… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Manager |
Affected:
0 , < 20.2.0.0 or later
(semver)
|
Date Public
2026-07-14 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-46738",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-23T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T03:56:07.554Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "20.2.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank WinD39 - Huynh Dinh Vu and Haxship1337 - Huynh Dinh Van for reporting this issue."
}
],
"datePublic": "2026-07-14T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-22T15:34:12.800Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-46738",
"datePublished": "2026-07-22T15:34:12.800Z",
"dateReserved": "2026-05-17T17:04:27.066Z",
"dateUpdated": "2026-07-24T03:56:07.554Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-40712 (GCVE-0-2026-40712)
Vulnerability from cvelistv5 – Published: 2026-07-22 15:28 – Updated: 2026-07-24 03:56
VLAI
EPSS
VEX
Summary
Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048884… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Manager |
Affected:
0 , < 20.2.0.0 or later
(semver)
|
Date Public
2026-07-14 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40712",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-23T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T03:56:06.739Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "20.2.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank WinD39 - Huynh Dinh Vu and Haxship1337 - Huynh Dinh Van for reporting this issue."
}
],
"datePublic": "2026-07-14T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability in the REST API. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-22T15:28:15.113Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-40712",
"datePublished": "2026-07-22T15:28:15.113Z",
"dateReserved": "2026-04-15T05:04:31.837Z",
"dateUpdated": "2026-07-24T03:56:06.739Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-40714 (GCVE-0-2026-40714)
Vulnerability from cvelistv5 – Published: 2026-07-22 15:20 – Updated: 2026-07-24 03:56
VLAI
EPSS
VEX
Summary
Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
Severity
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048884… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Manager |
Affected:
0 , < 20.2.0.0 or later
(semver)
|
Date Public
2026-07-14 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40714",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-23T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-24T03:56:05.881Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "20.2.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank WinD39 - Huynh Dinh Vu for reporting this issue."
}
],
"datePublic": "2026-07-14T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Improper Input Validation vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-22T15:20:35.358Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-40714",
"datePublished": "2026-07-22T15:20:35.358Z",
"dateReserved": "2026-04-15T05:04:31.837Z",
"dateUpdated": "2026-07-24T03:56:05.881Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-44276 (GCVE-0-2026-44276)
Vulnerability from cvelistv5 – Published: 2026-07-22 15:13 – Updated: 2026-07-22 15:55
VLAI
EPSS
VEX
Summary
Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the REST API. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure.
Severity
6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048884… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Manager |
Affected:
0 , < 20.2.0.0 or later
(semver)
|
Date Public
2026-07-14 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-44276",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-22T15:54:59.985096Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-22T15:55:09.983Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "20.2.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank shauntp for reporting this issue."
}
],
"datePublic": "2026-07-14T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the REST API. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure."
}
],
"value": "Dell PowerProtect Data Manager, versions prior to 20.2.0.0, contain(s) an Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the REST API. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information exposure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-22T15:13:07.215Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000488847/dsa-2026-287-security-update-dell-powerprotect-data-manager-for-multiple-security-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-44276",
"datePublished": "2026-07-22T15:13:07.215Z",
"dateReserved": "2026-05-05T17:04:45.714Z",
"dateUpdated": "2026-07-22T15:55:09.983Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-56687 (GCVE-0-2026-56687)
Vulnerability from cvelistv5 – Published: 2026-07-15 17:33 – Updated: 2026-07-16 03:55
VLAI
EPSS
VEX
Summary
Dell ThinOS 10, versions prior to 2605_10.2100, contain an Obsolete Feature in UI vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-448 - Obsolete Feature in UI
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048964… | vendor-advisory |
Impacted products
Date Public
2026-07-15 17:31
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-56687",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-16T03:55:52.361Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ThinOS 10",
"vendor": "Dell",
"versions": [
{
"lessThan": "2605_10.2100",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-15T17:31:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell ThinOS 10, versions prior to 2605_10.2100, contain an Obsolete Feature in UI vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"value": "Dell ThinOS 10, versions prior to 2605_10.2100, contain an Obsolete Feature in UI vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-448",
"description": "CWE-448: Obsolete Feature in UI",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T17:33:07.011Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000489640/dsa-2026-300-security-update-for-dell-thinos-10-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-56687",
"datePublished": "2026-07-15T17:33:07.011Z",
"dateReserved": "2026-06-22T17:04:26.238Z",
"dateUpdated": "2026-07-16T03:55:52.361Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-56087 (GCVE-0-2026-56087)
Vulnerability from cvelistv5 – Published: 2026-07-15 17:28 – Updated: 2026-07-15 19:30
VLAI
EPSS
VEX
Summary
Dell ThinOS 10, versions prior to 2605_10.2100 contain a Protection Mechanism Failure vulnerability. An attacker with physical access could potentially exploit this vulnerability, leading to unauthorized access to encrypted data.
Severity
6.1 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-693 - Protection Mechanism Failure
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048964… | vendor-advisory |
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-56087",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T19:30:30.327093Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T19:30:38.769Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ThinOS 10",
"vendor": "Dell",
"versions": [
{
"lessThan": "2605_10.2100",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell Technologies would like to thank Darren McDonald at AmberWolf for reporting this issue"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell ThinOS 10, versions prior to 2605_10.2100 contain a Protection Mechanism Failure vulnerability. An attacker with physical access could potentially exploit this vulnerability, leading to unauthorized access to encrypted data."
}
],
"value": "Dell ThinOS 10, versions prior to 2605_10.2100 contain a Protection Mechanism Failure vulnerability. An attacker with physical access could potentially exploit this vulnerability, leading to unauthorized access to encrypted data."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-693",
"description": "CWE-693: Protection Mechanism Failure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T17:28:03.944Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000489640/dsa-2026-300-security-update-for-dell-thinos-10-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-56087",
"datePublished": "2026-07-15T17:28:03.944Z",
"dateReserved": "2026-06-18T17:04:56.016Z",
"dateUpdated": "2026-07-15T19:30:38.769Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-40633 (GCVE-0-2026-40633)
Vulnerability from cvelistv5 – Published: 2026-07-15 10:07 – Updated: 2026-07-15 15:11
VLAI
EPSS
VEX
Summary
Dell PowerScale OneFS versions 9.5.0.0 through 9.10.1.7, versions 9.11.0.0 through 9.13.0.2 contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048360… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale OneFS |
Affected:
0 , < 9.10.1.8 or later
(semver)
Affected: 0 , < 9.13.1.0 or later (semver) |
Date Public
2026-06-30 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40633",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T13:42:56.612736Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T15:11:44.976Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale OneFS",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.10.1.8 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "9.13.1.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-06-30T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale OneFS versions 9.5.0.0 through 9.10.1.7, versions 9.11.0.0 through 9.13.0.2 contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell PowerScale OneFS versions 9.5.0.0 through 9.10.1.7, versions 9.11.0.0 through 9.13.0.2 contains an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T10:07:27.568Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000483600/dsa-2026-261-security-update-for-dell-powerscale-onefs-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-40633",
"datePublished": "2026-07-15T10:07:27.568Z",
"dateReserved": "2026-04-14T16:10:47.674Z",
"dateUpdated": "2026-07-15T15:11:44.976Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-49501 (GCVE-0-2026-49501)
Vulnerability from cvelistv5 – Published: 2026-07-15 10:01 – Updated: 2026-07-16 03:55
VLAI
EPSS
VEX
Summary
Dell PowerScale OneFS versions 9.5.0.0 through 9.10.1.7, and versions 9.11.0.0 through 9.13.0.2 contains an Improper Privilege Management vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.
Severity
6.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048360… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale OneFS |
Affected:
0 , < 9.10.1.8 or later
(semver)
Affected: 0 , < 9.13.1.0 or later (semver) |
Date Public
2026-06-30 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-49501",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-16T03:55:21.048Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerScale OneFS",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.10.1.8 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "9.13.1.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-06-30T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerScale OneFS versions 9.5.0.0 through 9.10.1.7, and versions 9.11.0.0 through 9.13.0.2 contains an Improper Privilege Management vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell PowerScale OneFS versions 9.5.0.0 through 9.10.1.7, and versions 9.11.0.0 through 9.13.0.2 contains an Improper Privilege Management vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269: Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T10:01:11.925Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000483600/dsa-2026-261-security-update-for-dell-powerscale-onefs-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-49501",
"datePublished": "2026-07-15T10:01:11.925Z",
"dateReserved": "2026-05-31T17:04:24.517Z",
"dateUpdated": "2026-07-16T03:55:21.048Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-54470 (GCVE-0-2026-54470)
Vulnerability from cvelistv5 – Published: 2026-07-10 12:20 – Updated: 2026-07-10 14:43
VLAI
EPSS
VEX
Summary
Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access.
Severity
5.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-611 - Improper Restriction of XML External Entity Reference
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048354… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Unisphere for PowerMax |
Affected:
0 , < 10.3.0.7 or later
(semver)
Affected: 0 , < 10.3.1.1 Patch 11360 or later (semver) |
Date Public
2026-07-09 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-54470",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-10T14:42:54.892451Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T14:43:05.838Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax",
"vendor": "Dell",
"versions": [
{
"lessThan": "10.3.0.7 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "10.3.1.1 Patch 11360 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-09T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"value": "Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior contain(s) an Improper Restriction of XML External Entity Reference vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-611",
"description": "CWE-611: Improper Restriction of XML External Entity Reference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T12:20:16.742Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000483543/dsa-2026-272-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtualappliance-dell-unisphere-360-dell-solutionsenabler-and-dell-solutionsenabler-virtualappliance-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-54470",
"datePublished": "2026-07-10T12:20:16.742Z",
"dateReserved": "2026-06-15T16:28:29.012Z",
"dateUpdated": "2026-07-10T14:43:05.838Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-54469 (GCVE-0-2026-54469)
Vulnerability from cvelistv5 – Published: 2026-07-10 12:14 – Updated: 2026-07-14 03:55
VLAI
EPSS
VEX
Summary
Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior, contain(s) a Deserialization of Untrusted Data vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048354… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Unisphere for PowerMax |
Affected:
0 , < 10.3.0.7 or later
(semver)
Affected: 0 , < 10.3.1.1 Patch 11360 or later (semver) |
Date Public
2026-07-09 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-54469",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-13T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T03:55:41.008Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax",
"vendor": "Dell",
"versions": [
{
"lessThan": "10.3.0.7 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "10.3.1.1 Patch 11360 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-09T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior, contain(s) a Deserialization of Untrusted Data vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges."
}
],
"value": "Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior, contain(s) a Deserialization of Untrusted Data vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T12:14:48.803Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000483543/dsa-2026-272-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtualappliance-dell-unisphere-360-dell-solutionsenabler-and-dell-solutionsenabler-virtualappliance-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-54469",
"datePublished": "2026-07-10T12:14:48.803Z",
"dateReserved": "2026-06-15T16:28:29.012Z",
"dateUpdated": "2026-07-14T03:55:41.008Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-54468 (GCVE-0-2026-54468)
Vulnerability from cvelistv5 – Published: 2026-07-10 12:09 – Updated: 2026-07-10 18:53
VLAI
EPSS
VEX
Summary
Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior, contain(s) a path traversal vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048354… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Unisphere for PowerMax |
Affected:
0 , < 10.3.0.7 or later
(semver)
Affected: 0 , < 10.3.1.1 Patch 11360 or later (semver) |
Date Public
2026-07-09 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-54468",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-10T18:52:53.950887Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T18:53:01.001Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Unisphere for PowerMax",
"vendor": "Dell",
"versions": [
{
"lessThan": "10.3.0.7 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "10.3.1.1 Patch 11360 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-09T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior, contain(s) a path traversal vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files."
}
],
"value": "Dell Unisphere for PowerMax, version(s) 10.3.0.5 and prior, contain(s) a path traversal vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability to read arbitrary files."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T12:09:05.546Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000483543/dsa-2026-272-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtualappliance-dell-unisphere-360-dell-solutionsenabler-and-dell-solutionsenabler-virtualappliance-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-54468",
"datePublished": "2026-07-10T12:09:05.546Z",
"dateReserved": "2026-06-15T16:28:29.012Z",
"dateUpdated": "2026-07-10T18:53:01.001Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-56688 (GCVE-0-2026-56688)
Vulnerability from cvelistv5 – Published: 2026-07-10 11:57 – Updated: 2026-07-10 17:01
VLAI
EPSS
VEX
Summary
Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00047753… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerFlex Manager |
Affected:
0 , < 5.1.0.1 or later
(semver)
Affected: 0 , < 4.5.5.2 or later (semver) |
Date Public
2026-07-06 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-56688",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-10T16:49:45.463721Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T17:01:12.022Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerFlex Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "5.1.0.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "4.5.5.2 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-06T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure."
}
],
"value": "Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T11:57:41.752Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000477538/dsa-2026-066-security-update-for-powerflex-software-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-56688",
"datePublished": "2026-07-10T11:57:41.752Z",
"dateReserved": "2026-06-22T17:04:26.238Z",
"dateUpdated": "2026-07-10T17:01:12.022Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}