Search
Find a vulnerability
Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
14 vulnerabilities by csa-iot
CVE-2025-56365 (GCVE-0-2025-56365)
Vulnerability from nvd – Published: 2026-07-14 00:00 – Updated: 2026-07-15 14:17
VLAI
EPSS
VEX
Summary
A reachable assertion vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.0, in the interaction model command processing logic. When an InvokeCommandRequest is sent to a nonexistent endpoint and cluster (e.g., 0x34), the code incorrectly treats the endpoint as valid due to missing checks in CodegenDataModelProvider::Invoke. This causes a VerifyOrDie failure in ProcessCommandDataIB and results in a crash (SIGABRT). The issue has been acknowledged and fixed in a later revision (PR #37207).
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-617 - Reachable Assertion
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-56365",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T14:17:47.869230Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-617",
"description": "CWE-617 Reachable Assertion",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T14:17:52.828Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/project-chip/connectedhomeip/issues/37184"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A reachable assertion vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.0, in the interaction model command processing logic. When an InvokeCommandRequest is sent to a nonexistent endpoint and cluster (e.g., 0x34), the code incorrectly treats the endpoint as valid due to missing checks in CodegenDataModelProvider::Invoke. This causes a VerifyOrDie failure in ProcessCommandDataIB and results in a crash (SIGABRT). The issue has been acknowledged and fixed in a later revision (PR #37207)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T22:17:14.897Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/project-chip/connectedhomeip/issues/37184"
},
{
"url": "https://github.com/project-chip/connectedhomeip/pull/37207"
},
{
"url": "https://github.com/project-chip/connectedhomeip/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-56365",
"datePublished": "2026-07-14T00:00:00.000Z",
"dateReserved": "2025-08-16T00:00:00.000Z",
"dateUpdated": "2026-07-15T14:17:52.828Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-56364 (GCVE-0-2025-56364)
Vulnerability from nvd – Published: 2026-07-14 00:00 – Updated: 2026-07-15 14:20
VLAI
EPSS
VEX
Summary
A use of uninitialized value vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.0, where the `GetDestinationGroupId().Value()` method is called without first checking whether a value exists. This leads to a crash when an InvokeCommand is sent without initializing the destination group ID. The issue affects all versions before commit 0360cc3 (Dec 5, 2024) and leads to denial of service through SIGABRT. It is fixed by adding a .HasValue() check before access.
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-457 - Use of Uninitialized Variable
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-56364",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T14:19:58.487174Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-457",
"description": "CWE-457 Use of Uninitialized Variable",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T14:20:03.829Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/project-chip/connectedhomeip/issues/36711"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A use of uninitialized value vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.0, where the `GetDestinationGroupId().Value()` method is called without first checking whether a value exists. This leads to a crash when an InvokeCommand is sent without initializing the destination group ID. The issue affects all versions before commit 0360cc3 (Dec 5, 2024) and leads to denial of service through SIGABRT. It is fixed by adding a .HasValue() check before access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T22:14:34.080Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/project-chip/connectedhomeip/issues/36711"
},
{
"url": "https://github.com/project-chip/connectedhomeip/pull/36729"
},
{
"url": "https://github.com/project-chip/connectedhomeip/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-56364",
"datePublished": "2026-07-14T00:00:00.000Z",
"dateReserved": "2025-08-16T00:00:00.000Z",
"dateUpdated": "2026-07-15T14:20:03.829Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-56363 (GCVE-0-2025-56363)
Vulnerability from nvd – Published: 2026-07-14 00:00 – Updated: 2026-07-15 14:21
VLAI
EPSS
VEX
Summary
A null pointer dereference vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.0, affecting the ReadRevisionAttribute function used in multiple clusters (Channel, Account Login, TargetNavigator, etc.). The function lacks proper validation of the delegate pointer before dereferencing. A remote unauthenticated attacker can exploit this issue by sending a crafted read request, causing the device to crash (denial of service). This issue has been confirmed in SDK version v1.4 (commit ab3d5ae).
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-476 - NULL Pointer Dereference
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-56363",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T14:21:44.328878Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476 NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T14:21:50.878Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/project-chip/connectedhomeip/issues/39173"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A null pointer dereference vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.0, affecting the ReadRevisionAttribute function used in multiple clusters (Channel, Account Login, TargetNavigator, etc.). The function lacks proper validation of the delegate pointer before dereferencing. A remote unauthenticated attacker can exploit this issue by sending a crafted read request, causing the device to crash (denial of service). This issue has been confirmed in SDK version v1.4 (commit ab3d5ae)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T22:19:59.869Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/project-chip/connectedhomeip/issues/39173"
},
{
"url": "https://github.com/project-chip/connectedhomeip/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-56363",
"datePublished": "2026-07-14T00:00:00.000Z",
"dateReserved": "2025-08-16T00:00:00.000Z",
"dateUpdated": "2026-07-15T14:21:50.878Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-56362 (GCVE-0-2025-56362)
Vulnerability from nvd – Published: 2026-07-14 00:00 – Updated: 2026-07-15 14:23
VLAI
EPSS
VEX
Summary
A reachable assertion vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.2, specifically within the Level Control cluster's periodic server tick logic. When a MoveToLevel command is sent and immediately followed by a write of OperationMode=2 (in the Pump Configuration and Control cluster), the server tick function violates the assertion `currentLevel < maxLevel`, resulting in a crash. This can be exploited remotely without authentication to cause denial of service. Affected versions include 1.3 and 1.4 (commit ab3d5ae).
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-617 - Reachable Assertion
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-56362",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T14:23:12.573010Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-617",
"description": "CWE-617 Reachable Assertion",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T14:23:19.667Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/project-chip/connectedhomeip/issues/38618"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A reachable assertion vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.2, specifically within the Level Control cluster\u0027s periodic server tick logic. When a MoveToLevel command is sent and immediately followed by a write of OperationMode=2 (in the Pump Configuration and Control cluster), the server tick function violates the assertion `currentLevel \u003c maxLevel`, resulting in a crash. This can be exploited remotely without authentication to cause denial of service. Affected versions include 1.3 and 1.4 (commit ab3d5ae)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T22:11:46.567Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/project-chip/connectedhomeip/issues/38618"
},
{
"url": "https://github.com/project-chip/connectedhomeip/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-56362",
"datePublished": "2026-07-14T00:00:00.000Z",
"dateReserved": "2025-08-16T00:00:00.000Z",
"dateUpdated": "2026-07-15T14:23:19.667Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-56361 (GCVE-0-2025-56361)
Vulnerability from nvd – Published: 2026-07-14 00:00 – Updated: 2026-07-15 14:27
VLAI
EPSS
VEX
Summary
A reachable assertion vulnerability exists in the Matter SDK (connectedhomeip) 1.3 thru 1.4, specifically within the Level Control cluster's server tick logic (`emberAfLevelControlClusterServerTickCallback`). When a MoveToLevel command is executed and followed by a conflicting write to the OperationMode attribute (in the Pump Configuration and Control cluster), an invariant check (`minLevel < currentLevel`) fails and causes the device to abort. This leads to a denial of service condition. The issue is confirmed in SDK versions 1.3 and 1.4 (commit ab3d5ae), and is triggered remotely without authentication.
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-617 - Reachable Assertion
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-56361",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T14:27:10.701001Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-617",
"description": "CWE-617 Reachable Assertion",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T14:27:15.683Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/project-chip/connectedhomeip/issues/38619"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A reachable assertion vulnerability exists in the Matter SDK (connectedhomeip) 1.3 thru 1.4, specifically within the Level Control cluster\u0027s server tick logic (`emberAfLevelControlClusterServerTickCallback`). When a MoveToLevel command is executed and followed by a conflicting write to the OperationMode attribute (in the Pump Configuration and Control cluster), an invariant check (`minLevel \u003c currentLevel`) fails and causes the device to abort. This leads to a denial of service condition. The issue is confirmed in SDK versions 1.3 and 1.4 (commit ab3d5ae), and is triggered remotely without authentication."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T21:32:49.588Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/project-chip/connectedhomeip/issues/38619"
},
{
"url": "https://github.com/project-chip/connectedhomeip/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-56361",
"datePublished": "2026-07-14T00:00:00.000Z",
"dateReserved": "2025-08-16T00:00:00.000Z",
"dateUpdated": "2026-07-15T14:27:15.683Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-3454 (GCVE-0-2024-3454)
Vulnerability from nvd – Published: 2024-07-24 07:58 – Updated: 2024-08-01 20:12
VLAI
EPSS
VEX
Title
In-Fabric Matter Cluster Attribute Disclosure
Summary
An implementation issue in the Connectivity Standards Alliance Matter 1.2 protocol as used in the connectedhomeip SDK allows a third party to disclose information about devices part of the same fabric (footprinting), even though the protocol is designed to prevent access to such information.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-209 - Generation of Error Message Containing Sensitive Information
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.bitdefender.com/support/security-advi… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Connectivity Standards Alliance | connectedhomeip |
Affected:
1.2.0.1
|
Date Public
2024-07-22 09:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3454",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-26T17:10:03.662727Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-26T17:10:19.118Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:12:06.908Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://www.bitdefender.com/support/security-advisories/in-fabric-matter-cluster-attribute-disclosure/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "connectedhomeip",
"vendor": "Connectivity Standards Alliance",
"versions": [
{
"status": "affected",
"version": "1.2.0.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bela Genge, Bitdefender"
}
],
"datePublic": "2024-07-22T09:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An implementation issue in the Connectivity Standards Alliance Matter 1.2 protocol as used in the connectedhomeip SDK allows a third party to disclose information about devices part of the same fabric (footprinting), even though the protocol is designed to prevent access to such information."
}
],
"value": "An implementation issue in the Connectivity Standards Alliance Matter 1.2 protocol as used in the connectedhomeip SDK allows a third party to disclose information about devices part of the same fabric (footprinting), even though the protocol is designed to prevent access to such information."
}
],
"impacts": [
{
"capecId": "CAPEC-169",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-169 Footprinting"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-209",
"description": "CWE-209: Generation of Error Message Containing Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-24T07:58:40.219Z",
"orgId": "b3d5ebe7-963e-41fb-98e1-2edaeabb8f82",
"shortName": "Bitdefender"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.bitdefender.com/support/security-advisories/in-fabric-matter-cluster-attribute-disclosure/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "In-Fabric Matter Cluster Attribute Disclosure",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b3d5ebe7-963e-41fb-98e1-2edaeabb8f82",
"assignerShortName": "Bitdefender",
"cveId": "CVE-2024-3454",
"datePublished": "2024-07-24T07:58:40.219Z",
"dateReserved": "2024-04-08T10:10:40.308Z",
"dateUpdated": "2024-08-01T20:12:06.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3297 (GCVE-0-2024-3297)
Vulnerability from nvd – Published: 2024-07-24 08:02 – Updated: 2024-08-01 20:05
VLAI
EPSS
VEX
Title
Session establishment lock-up during replay of CASE Sigma1 messages
Summary
An issue in the Certificate Authenticated Session Establishment (CASE) protocol for establishing secure sessions between two devices, as implemented in the Matter protocol versions before Matter 1.1 allows an attacker to replay manipulated CASE Sigma1 messages to make the device unresponsive until the device is power-cycled.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Connectivity Standards Alliance | Matter |
Affected:
0 , < 1.1
(custom)
|
Date Public
2024-06-24 08:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3297",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-24T13:05:02.563355Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-24T13:05:27.852Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:05:08.480Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.bitdefender.com/support/security-advisories/session-establishment-lock-up-during-replay-of-case-sigma1-messages/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Matter",
"vendor": "Connectivity Standards Alliance",
"versions": [
{
"lessThan": "1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bela Genge, Bitdefender"
}
],
"datePublic": "2024-06-24T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An issue in the Certificate Authenticated Session Establishment (CASE) protocol for establishing secure sessions between two devices, as implemented in the Matter protocol versions before Matter 1.1 allows an attacker to replay manipulated CASE Sigma1 messages to make the device unresponsive until\u0026nbsp;the device is power-cycled."
}
],
"value": "An issue in the Certificate Authenticated Session Establishment (CASE) protocol for establishing secure sessions between two devices, as implemented in the Matter protocol versions before Matter 1.1 allows an attacker to replay manipulated CASE Sigma1 messages to make the device unresponsive until\u00a0the device is power-cycled."
}
],
"impacts": [
{
"capecId": "CAPEC-125",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-125 Flooding"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-24T08:02:52.777Z",
"orgId": "b3d5ebe7-963e-41fb-98e1-2edaeabb8f82",
"shortName": "Bitdefender"
},
"references": [
{
"url": "https://www.bitdefender.com/support/security-advisories/session-establishment-lock-up-during-replay-of-case-sigma1-messages/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Session establishment lock-up during replay of CASE Sigma1 messages",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b3d5ebe7-963e-41fb-98e1-2edaeabb8f82",
"assignerShortName": "Bitdefender",
"cveId": "CVE-2024-3297",
"datePublished": "2024-07-24T08:02:52.777Z",
"dateReserved": "2024-04-04T08:52:49.854Z",
"dateUpdated": "2024-08-01T20:05:08.480Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-56364 (GCVE-0-2025-56364)
Vulnerability from cvelistv5 – Published: 2026-07-14 00:00 – Updated: 2026-07-15 14:20
VLAI
EPSS
VEX
Summary
A use of uninitialized value vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.0, where the `GetDestinationGroupId().Value()` method is called without first checking whether a value exists. This leads to a crash when an InvokeCommand is sent without initializing the destination group ID. The issue affects all versions before commit 0360cc3 (Dec 5, 2024) and leads to denial of service through SIGABRT. It is fixed by adding a .HasValue() check before access.
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-457 - Use of Uninitialized Variable
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-56364",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T14:19:58.487174Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-457",
"description": "CWE-457 Use of Uninitialized Variable",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T14:20:03.829Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/project-chip/connectedhomeip/issues/36711"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A use of uninitialized value vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.0, where the `GetDestinationGroupId().Value()` method is called without first checking whether a value exists. This leads to a crash when an InvokeCommand is sent without initializing the destination group ID. The issue affects all versions before commit 0360cc3 (Dec 5, 2024) and leads to denial of service through SIGABRT. It is fixed by adding a .HasValue() check before access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T22:14:34.080Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/project-chip/connectedhomeip/issues/36711"
},
{
"url": "https://github.com/project-chip/connectedhomeip/pull/36729"
},
{
"url": "https://github.com/project-chip/connectedhomeip/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-56364",
"datePublished": "2026-07-14T00:00:00.000Z",
"dateReserved": "2025-08-16T00:00:00.000Z",
"dateUpdated": "2026-07-15T14:20:03.829Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-56361 (GCVE-0-2025-56361)
Vulnerability from cvelistv5 – Published: 2026-07-14 00:00 – Updated: 2026-07-15 14:27
VLAI
EPSS
VEX
Summary
A reachable assertion vulnerability exists in the Matter SDK (connectedhomeip) 1.3 thru 1.4, specifically within the Level Control cluster's server tick logic (`emberAfLevelControlClusterServerTickCallback`). When a MoveToLevel command is executed and followed by a conflicting write to the OperationMode attribute (in the Pump Configuration and Control cluster), an invariant check (`minLevel < currentLevel`) fails and causes the device to abort. This leads to a denial of service condition. The issue is confirmed in SDK versions 1.3 and 1.4 (commit ab3d5ae), and is triggered remotely without authentication.
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-617 - Reachable Assertion
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-56361",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T14:27:10.701001Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-617",
"description": "CWE-617 Reachable Assertion",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T14:27:15.683Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/project-chip/connectedhomeip/issues/38619"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A reachable assertion vulnerability exists in the Matter SDK (connectedhomeip) 1.3 thru 1.4, specifically within the Level Control cluster\u0027s server tick logic (`emberAfLevelControlClusterServerTickCallback`). When a MoveToLevel command is executed and followed by a conflicting write to the OperationMode attribute (in the Pump Configuration and Control cluster), an invariant check (`minLevel \u003c currentLevel`) fails and causes the device to abort. This leads to a denial of service condition. The issue is confirmed in SDK versions 1.3 and 1.4 (commit ab3d5ae), and is triggered remotely without authentication."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T21:32:49.588Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/project-chip/connectedhomeip/issues/38619"
},
{
"url": "https://github.com/project-chip/connectedhomeip/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-56361",
"datePublished": "2026-07-14T00:00:00.000Z",
"dateReserved": "2025-08-16T00:00:00.000Z",
"dateUpdated": "2026-07-15T14:27:15.683Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-56363 (GCVE-0-2025-56363)
Vulnerability from cvelistv5 – Published: 2026-07-14 00:00 – Updated: 2026-07-15 14:21
VLAI
EPSS
VEX
Summary
A null pointer dereference vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.0, affecting the ReadRevisionAttribute function used in multiple clusters (Channel, Account Login, TargetNavigator, etc.). The function lacks proper validation of the delegate pointer before dereferencing. A remote unauthenticated attacker can exploit this issue by sending a crafted read request, causing the device to crash (denial of service). This issue has been confirmed in SDK version v1.4 (commit ab3d5ae).
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-476 - NULL Pointer Dereference
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-56363",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T14:21:44.328878Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476 NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T14:21:50.878Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/project-chip/connectedhomeip/issues/39173"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A null pointer dereference vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.0, affecting the ReadRevisionAttribute function used in multiple clusters (Channel, Account Login, TargetNavigator, etc.). The function lacks proper validation of the delegate pointer before dereferencing. A remote unauthenticated attacker can exploit this issue by sending a crafted read request, causing the device to crash (denial of service). This issue has been confirmed in SDK version v1.4 (commit ab3d5ae)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T22:19:59.869Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/project-chip/connectedhomeip/issues/39173"
},
{
"url": "https://github.com/project-chip/connectedhomeip/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-56363",
"datePublished": "2026-07-14T00:00:00.000Z",
"dateReserved": "2025-08-16T00:00:00.000Z",
"dateUpdated": "2026-07-15T14:21:50.878Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-56362 (GCVE-0-2025-56362)
Vulnerability from cvelistv5 – Published: 2026-07-14 00:00 – Updated: 2026-07-15 14:23
VLAI
EPSS
VEX
Summary
A reachable assertion vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.2, specifically within the Level Control cluster's periodic server tick logic. When a MoveToLevel command is sent and immediately followed by a write of OperationMode=2 (in the Pump Configuration and Control cluster), the server tick function violates the assertion `currentLevel < maxLevel`, resulting in a crash. This can be exploited remotely without authentication to cause denial of service. Affected versions include 1.3 and 1.4 (commit ab3d5ae).
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-617 - Reachable Assertion
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-56362",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T14:23:12.573010Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-617",
"description": "CWE-617 Reachable Assertion",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T14:23:19.667Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/project-chip/connectedhomeip/issues/38618"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A reachable assertion vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.2, specifically within the Level Control cluster\u0027s periodic server tick logic. When a MoveToLevel command is sent and immediately followed by a write of OperationMode=2 (in the Pump Configuration and Control cluster), the server tick function violates the assertion `currentLevel \u003c maxLevel`, resulting in a crash. This can be exploited remotely without authentication to cause denial of service. Affected versions include 1.3 and 1.4 (commit ab3d5ae)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T22:11:46.567Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/project-chip/connectedhomeip/issues/38618"
},
{
"url": "https://github.com/project-chip/connectedhomeip/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-56362",
"datePublished": "2026-07-14T00:00:00.000Z",
"dateReserved": "2025-08-16T00:00:00.000Z",
"dateUpdated": "2026-07-15T14:23:19.667Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-56365 (GCVE-0-2025-56365)
Vulnerability from cvelistv5 – Published: 2026-07-14 00:00 – Updated: 2026-07-15 14:17
VLAI
EPSS
VEX
Summary
A reachable assertion vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.0, in the interaction model command processing logic. When an InvokeCommandRequest is sent to a nonexistent endpoint and cluster (e.g., 0x34), the code incorrectly treats the endpoint as valid due to missing checks in CodegenDataModelProvider::Invoke. This causes a VerifyOrDie failure in ProcessCommandDataIB and results in a crash (SIGABRT). The issue has been acknowledged and fixed in a later revision (PR #37207).
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-617 - Reachable Assertion
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-56365",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-15T14:17:47.869230Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-617",
"description": "CWE-617 Reachable Assertion",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T14:17:52.828Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/project-chip/connectedhomeip/issues/37184"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A reachable assertion vulnerability exists in the Matter SDK (connectedhomeip) before 1.4.0, in the interaction model command processing logic. When an InvokeCommandRequest is sent to a nonexistent endpoint and cluster (e.g., 0x34), the code incorrectly treats the endpoint as valid due to missing checks in CodegenDataModelProvider::Invoke. This causes a VerifyOrDie failure in ProcessCommandDataIB and results in a crash (SIGABRT). The issue has been acknowledged and fixed in a later revision (PR #37207)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T22:17:14.897Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/project-chip/connectedhomeip/issues/37184"
},
{
"url": "https://github.com/project-chip/connectedhomeip/pull/37207"
},
{
"url": "https://github.com/project-chip/connectedhomeip/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-56365",
"datePublished": "2026-07-14T00:00:00.000Z",
"dateReserved": "2025-08-16T00:00:00.000Z",
"dateUpdated": "2026-07-15T14:17:52.828Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-3297 (GCVE-0-2024-3297)
Vulnerability from cvelistv5 – Published: 2024-07-24 08:02 – Updated: 2024-08-01 20:05
VLAI
EPSS
VEX
Title
Session establishment lock-up during replay of CASE Sigma1 messages
Summary
An issue in the Certificate Authenticated Session Establishment (CASE) protocol for establishing secure sessions between two devices, as implemented in the Matter protocol versions before Matter 1.1 allows an attacker to replay manipulated CASE Sigma1 messages to make the device unresponsive until the device is power-cycled.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Connectivity Standards Alliance | Matter |
Affected:
0 , < 1.1
(custom)
|
Date Public
2024-06-24 08:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3297",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-24T13:05:02.563355Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-24T13:05:27.852Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:05:08.480Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.bitdefender.com/support/security-advisories/session-establishment-lock-up-during-replay-of-case-sigma1-messages/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Matter",
"vendor": "Connectivity Standards Alliance",
"versions": [
{
"lessThan": "1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bela Genge, Bitdefender"
}
],
"datePublic": "2024-06-24T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An issue in the Certificate Authenticated Session Establishment (CASE) protocol for establishing secure sessions between two devices, as implemented in the Matter protocol versions before Matter 1.1 allows an attacker to replay manipulated CASE Sigma1 messages to make the device unresponsive until\u0026nbsp;the device is power-cycled."
}
],
"value": "An issue in the Certificate Authenticated Session Establishment (CASE) protocol for establishing secure sessions between two devices, as implemented in the Matter protocol versions before Matter 1.1 allows an attacker to replay manipulated CASE Sigma1 messages to make the device unresponsive until\u00a0the device is power-cycled."
}
],
"impacts": [
{
"capecId": "CAPEC-125",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-125 Flooding"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-24T08:02:52.777Z",
"orgId": "b3d5ebe7-963e-41fb-98e1-2edaeabb8f82",
"shortName": "Bitdefender"
},
"references": [
{
"url": "https://www.bitdefender.com/support/security-advisories/session-establishment-lock-up-during-replay-of-case-sigma1-messages/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Session establishment lock-up during replay of CASE Sigma1 messages",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b3d5ebe7-963e-41fb-98e1-2edaeabb8f82",
"assignerShortName": "Bitdefender",
"cveId": "CVE-2024-3297",
"datePublished": "2024-07-24T08:02:52.777Z",
"dateReserved": "2024-04-04T08:52:49.854Z",
"dateUpdated": "2024-08-01T20:05:08.480Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3454 (GCVE-0-2024-3454)
Vulnerability from cvelistv5 – Published: 2024-07-24 07:58 – Updated: 2024-08-01 20:12
VLAI
EPSS
VEX
Title
In-Fabric Matter Cluster Attribute Disclosure
Summary
An implementation issue in the Connectivity Standards Alliance Matter 1.2 protocol as used in the connectedhomeip SDK allows a third party to disclose information about devices part of the same fabric (footprinting), even though the protocol is designed to prevent access to such information.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-209 - Generation of Error Message Containing Sensitive Information
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.bitdefender.com/support/security-advi… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Connectivity Standards Alliance | connectedhomeip |
Affected:
1.2.0.1
|
Date Public
2024-07-22 09:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3454",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-26T17:10:03.662727Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-26T17:10:19.118Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:12:06.908Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://www.bitdefender.com/support/security-advisories/in-fabric-matter-cluster-attribute-disclosure/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "connectedhomeip",
"vendor": "Connectivity Standards Alliance",
"versions": [
{
"status": "affected",
"version": "1.2.0.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bela Genge, Bitdefender"
}
],
"datePublic": "2024-07-22T09:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An implementation issue in the Connectivity Standards Alliance Matter 1.2 protocol as used in the connectedhomeip SDK allows a third party to disclose information about devices part of the same fabric (footprinting), even though the protocol is designed to prevent access to such information."
}
],
"value": "An implementation issue in the Connectivity Standards Alliance Matter 1.2 protocol as used in the connectedhomeip SDK allows a third party to disclose information about devices part of the same fabric (footprinting), even though the protocol is designed to prevent access to such information."
}
],
"impacts": [
{
"capecId": "CAPEC-169",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-169 Footprinting"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-209",
"description": "CWE-209: Generation of Error Message Containing Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-24T07:58:40.219Z",
"orgId": "b3d5ebe7-963e-41fb-98e1-2edaeabb8f82",
"shortName": "Bitdefender"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.bitdefender.com/support/security-advisories/in-fabric-matter-cluster-attribute-disclosure/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "In-Fabric Matter Cluster Attribute Disclosure",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b3d5ebe7-963e-41fb-98e1-2edaeabb8f82",
"assignerShortName": "Bitdefender",
"cveId": "CVE-2024-3454",
"datePublished": "2024-07-24T07:58:40.219Z",
"dateReserved": "2024-04-08T10:10:40.308Z",
"dateUpdated": "2024-08-01T20:12:06.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}