Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    18 vulnerabilities by Elcomplus

    CVE-2022-2140 (GCVE-0-2022-2140)

    Vulnerability from nvd – Published: 2022-06-27 16:14 – Updated: 2025-04-16 17:51
    VLAI
    Title
    Elcomplus SmartICS Cross-site Scripting
    Summary
    Elcomplus SmartICS v2.3.4.0 does not neutralize user-controllable input, which allows an authenticated user to inject arbitrary code into specific parameters.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Cross-site Scripting
    Assigner
    References
    Impacted products
    Vendor Product Version
    Elcomplus SmartICS Affected: v2.3.4.0
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T00:24:44.252Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-2140",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:28:23.195962Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:51:46.939Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartICS",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "v2.3.4.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartICS v2.3.4.0 does not neutralize user-controllable input, which allows an authenticated user to inject arbitrary code into specific parameters."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Cross-site Scripting",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-27T16:14:48.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released Version 2.4 to address these vulnerabilities and recommends users update to the newest version. Users can obtain the new version on request on the official SmartICS website https://smartics.io/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Elcomplus SmartICS Cross-site Scripting",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2022-2140",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartICS Cross-site Scripting"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartICS",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "v2.3.4.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartICS v2.3.4.0 does not neutralize user-controllable input, which allows an authenticated user to inject arbitrary code into specific parameters."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-79: Cross-site Scripting"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released Version 2.4 to address these vulnerabilities and recommends users update to the newest version. Users can obtain the new version on request on the official SmartICS website https://smartics.io/"
              }
            ],
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-2140",
        "datePublished": "2022-06-27T16:14:48.000Z",
        "dateReserved": "2022-06-20T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:51:46.939Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-2106 (GCVE-0-2022-2106)

    Vulnerability from nvd – Published: 2022-06-27 16:15 – Updated: 2025-04-16 16:15
    VLAI
    Title
    Elcomplus SmartICS Path Traversal
    Summary
    Elcomplus SmartICS v2.3.4.0 does not validate the filenames sufficiently, which enables authenticated administrator-level users to perform path traversal attacks and specify arbitrary files.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-23 - Relative Path Traversal
    Assigner
    References
    Impacted products
    Vendor Product Version
    Elcomplus SmartICS Affected: v2.3.4.0
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T00:24:44.184Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-2106",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:51:19.632959Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:15:46.034Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartICS",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "v2.3.4.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartICS v2.3.4.0 does not validate the filenames sufficiently, which enables authenticated administrator-level users to perform path traversal attacks and specify arbitrary files."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 3.8,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-23",
                  "description": "CWE-23 Relative Path Traversal",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-27T16:15:32.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released Version 2.4 to address these vulnerabilities and recommends users update to the newest version. Users can obtain the new version on request on the official SmartICS website https://smartics.io/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Elcomplus SmartICS Path Traversal",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2022-2106",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartICS Path Traversal"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartICS",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "v2.3.4.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartICS v2.3.4.0 does not validate the filenames sufficiently, which enables authenticated administrator-level users to perform path traversal attacks and specify arbitrary files."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 3.8,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-23 Relative Path Traversal"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released Version 2.4 to address these vulnerabilities and recommends users update to the newest version. Users can obtain the new version on request on the official SmartICS website https://smartics.io/"
              }
            ],
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-2106",
        "datePublished": "2022-06-27T16:15:32.000Z",
        "dateReserved": "2022-06-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:15:46.034Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-2088 (GCVE-0-2022-2088)

    Vulnerability from nvd – Published: 2022-06-27 16:14 – Updated: 2025-04-16 16:15
    VLAI
    Title
    Elcomplus SmartICS Access Control
    Summary
    An authenticated user with admin privileges may be able to terminate any process on the system running Elcomplus SmartICS v2.3.4.0.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    Elcomplus SmartICS Affected: v2.3.4.0
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T00:24:44.271Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-2088",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:51:23.100138Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:15:53.017Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartICS",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "v2.3.4.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An authenticated user with admin privileges may be able to terminate any process on the system running Elcomplus SmartICS v2.3.4.0."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-27T16:14:07.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released Version 2.4 to address these vulnerabilities and recommends users update to the newest version. Users can obtain the new version on request on the official SmartICS website https://smartics.io/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Elcomplus SmartICS Access Control",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2022-2088",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartICS Access Control"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartICS",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "v2.3.4.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An authenticated user with admin privileges may be able to terminate any process on the system running Elcomplus SmartICS v2.3.4.0."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-284: Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released Version 2.4 to address these vulnerabilities and recommends users update to the newest version. Users can obtain the new version on request on the official SmartICS website https://smartics.io/"
              }
            ],
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-2088",
        "datePublished": "2022-06-27T16:14:07.000Z",
        "dateReserved": "2022-06-15T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:15:53.017Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43938 (GCVE-0-2021-43938)

    Vulnerability from nvd – Published: 2022-04-29 15:18 – Updated: 2025-04-16 17:54
    VLAI
    Title
    Elcomplus SmartPTT SCADA Server Information Exposure
    Summary
    Elcomplus SmartPTT SCADA Server is vulnerable to an unauthenticated user can request various files from the server without any authentication or authorization.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.167Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43938",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:29:23.959570Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:54:48.244Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartPTT SCADA Server",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.4"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartPTT SCADA Server is vulnerable to an unauthenticated user can request various files from the server without any authentication or authorization."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-29T15:18:14.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-05",
            "discovery": "UNKNOWN"
          },
          "title": "Elcomplus SmartPTT SCADA Server Information Exposure",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2021-43938",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartPTT SCADA Server Information Exposure"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartPTT SCADA Server",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartPTT SCADA Server is vulnerable to an unauthenticated user can request various files from the server without any authentication or authorization."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-200 Information Exposure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-05",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43938",
        "datePublished": "2022-04-29T15:18:14.000Z",
        "dateReserved": "2021-11-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:54:48.244Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43937 (GCVE-0-2021-43937)

    Vulnerability from nvd – Published: 2022-04-29 15:17 – Updated: 2025-04-16 16:27
    VLAI
    Title
    Elcomplus SmartPTT SCADA Server Cross-site Request Forgery
    Summary
    Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.001Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43937",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:53:11.629914Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:27:36.910Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartPTT SCADA Server",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.4"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-29T15:17:35.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-05",
            "discovery": "UNKNOWN"
          },
          "title": "Elcomplus SmartPTT SCADA Server Cross-site Request Forgery",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2021-43937",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartPTT SCADA Server Cross-site Request Forgery"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartPTT SCADA Server",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-200 Information Exposure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-05",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43937",
        "datePublished": "2022-04-29T15:17:35.000Z",
        "dateReserved": "2021-11-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:27:36.910Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43939 (GCVE-0-2021-43939)

    Vulnerability from nvd – Published: 2022-04-28 14:55 – Updated: 2025-04-16 17:54
    VLAI
    Title
    Elcomplus SmartPtt Improper Authorization
    Summary
    Elcomplus SmartPTT is vulnerable when a low-authenticated user can access higher level administration authorization by issuing requests directly to the desired endpoints.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Elcomplus SmartPTT Affected: 1.1
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.163Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43939",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:29:26.986605Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:54:55.849Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartPTT",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartPTT is vulnerable when a low-authenticated user can access higher level administration authorization by issuing requests directly to the desired endpoints."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-285",
                  "description": "CWE-285 Improper Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-28T14:55:52.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-04",
            "discovery": "UNKNOWN"
          },
          "title": "Elcomplus SmartPtt Improper Authorization",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2021-43939",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartPtt Improper Authorization"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartPTT",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartPTT is vulnerable when a low-authenticated user can access higher level administration authorization by issuing requests directly to the desired endpoints."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-285 Improper Authorization"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-04",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43939",
        "datePublished": "2022-04-28T14:55:52.000Z",
        "dateReserved": "2021-11-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:54:55.849Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43934 (GCVE-0-2021-43934)

    Vulnerability from nvd – Published: 2022-04-28 14:54 – Updated: 2025-04-16 16:27
    VLAI
    Title
    Elcomplus SmartPtt Unrestricted Upload of File with Dangerous Type
    Summary
    Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate upload requests, enabling a malicious user to potentially upload arbitrary files.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-434 - Unrestricted Upload of File with Dangerous Type
    Assigner
    References
    Impacted products
    Vendor Product Version
    Elcomplus SmartPTT Affected: 1.1
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.090Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43934",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:56:01.823973Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:27:44.690Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartPTT",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate upload requests, enabling a malicious user to potentially upload arbitrary files."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-28T14:54:20.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-04",
            "discovery": "UNKNOWN"
          },
          "title": "Elcomplus SmartPtt Unrestricted Upload of File with Dangerous Type",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2021-43934",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartPtt Unrestricted Upload of File with Dangerous Type"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartPTT",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate upload requests, enabling a malicious user to potentially upload arbitrary files."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-434 Unrestricted Upload of File with Dangerous Type"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-04",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43934",
        "datePublished": "2022-04-28T14:54:20.000Z",
        "dateReserved": "2021-11-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:27:44.690Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43932 (GCVE-0-2021-43932)

    Vulnerability from nvd – Published: 2022-04-28 14:54 – Updated: 2025-04-16 17:55
    VLAI
    Title
    Elcomplus SmartPtt Cross-site Scripting
    Summary
    Elcomplus SmartPTT is vulnerable when an attacker injects JavaScript code into a specific parameter that can executed upon accessing the dashboard or the main page.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Cross-site Scripting (XSS)
    Assigner
    References
    Impacted products
    Vendor Product Version
    Elcomplus SmartPTT Affected: 1.1
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:16.306Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43932",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:29:30.624901Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:55:04.470Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartPTT",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartPTT is vulnerable when an attacker injects JavaScript code into a specific parameter that can executed upon accessing the dashboard or the main page."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Cross-site Scripting (XSS)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-28T14:54:57.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-04",
            "discovery": "UNKNOWN"
          },
          "title": "Elcomplus SmartPtt Cross-site Scripting",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2021-43932",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartPtt Cross-site Scripting"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartPTT",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartPTT is vulnerable when an attacker injects JavaScript code into a specific parameter that can executed upon accessing the dashboard or the main page."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-79 Cross-site Scripting (XSS)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-04",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43932",
        "datePublished": "2022-04-28T14:54:57.000Z",
        "dateReserved": "2021-11-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:55:04.470Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43930 (GCVE-0-2021-43930)

    Vulnerability from nvd – Published: 2022-04-28 14:53 – Updated: 2025-04-16 16:27
    VLAI
    Title
    Elcomplus SmartPtt Path Traversal
    Summary
    Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate download requests, enabling malicious users to perform path traversal attacks and potentially download arbitrary files from the system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Elcomplus SmartPTT Affected: 1.1
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:16.986Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43930",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:53:15.384399Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:27:52.498Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartPTT",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate download requests, enabling malicious users to perform path traversal attacks and potentially download arbitrary files from the system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-28T14:53:29.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-04",
            "discovery": "UNKNOWN"
          },
          "title": "Elcomplus SmartPtt Path Traversal",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2021-43930",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartPtt Path Traversal"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartPTT",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate download requests, enabling malicious users to perform path traversal attacks and potentially download arbitrary files from the system."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-04",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43930",
        "datePublished": "2022-04-28T14:53:29.000Z",
        "dateReserved": "2021-11-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:27:52.498Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-2106 (GCVE-0-2022-2106)

    Vulnerability from cvelistv5 – Published: 2022-06-27 16:15 – Updated: 2025-04-16 16:15
    VLAI
    Title
    Elcomplus SmartICS Path Traversal
    Summary
    Elcomplus SmartICS v2.3.4.0 does not validate the filenames sufficiently, which enables authenticated administrator-level users to perform path traversal attacks and specify arbitrary files.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-23 - Relative Path Traversal
    Assigner
    References
    Impacted products
    Vendor Product Version
    Elcomplus SmartICS Affected: v2.3.4.0
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T00:24:44.184Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-2106",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:51:19.632959Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:15:46.034Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartICS",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "v2.3.4.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartICS v2.3.4.0 does not validate the filenames sufficiently, which enables authenticated administrator-level users to perform path traversal attacks and specify arbitrary files."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 3.8,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-23",
                  "description": "CWE-23 Relative Path Traversal",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-27T16:15:32.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released Version 2.4 to address these vulnerabilities and recommends users update to the newest version. Users can obtain the new version on request on the official SmartICS website https://smartics.io/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Elcomplus SmartICS Path Traversal",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2022-2106",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartICS Path Traversal"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartICS",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "v2.3.4.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartICS v2.3.4.0 does not validate the filenames sufficiently, which enables authenticated administrator-level users to perform path traversal attacks and specify arbitrary files."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 3.8,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-23 Relative Path Traversal"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released Version 2.4 to address these vulnerabilities and recommends users update to the newest version. Users can obtain the new version on request on the official SmartICS website https://smartics.io/"
              }
            ],
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-2106",
        "datePublished": "2022-06-27T16:15:32.000Z",
        "dateReserved": "2022-06-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:15:46.034Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-2140 (GCVE-0-2022-2140)

    Vulnerability from cvelistv5 – Published: 2022-06-27 16:14 – Updated: 2025-04-16 17:51
    VLAI
    Title
    Elcomplus SmartICS Cross-site Scripting
    Summary
    Elcomplus SmartICS v2.3.4.0 does not neutralize user-controllable input, which allows an authenticated user to inject arbitrary code into specific parameters.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Cross-site Scripting
    Assigner
    References
    Impacted products
    Vendor Product Version
    Elcomplus SmartICS Affected: v2.3.4.0
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T00:24:44.252Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-2140",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:28:23.195962Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:51:46.939Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartICS",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "v2.3.4.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartICS v2.3.4.0 does not neutralize user-controllable input, which allows an authenticated user to inject arbitrary code into specific parameters."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Cross-site Scripting",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-27T16:14:48.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released Version 2.4 to address these vulnerabilities and recommends users update to the newest version. Users can obtain the new version on request on the official SmartICS website https://smartics.io/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Elcomplus SmartICS Cross-site Scripting",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2022-2140",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartICS Cross-site Scripting"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartICS",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "v2.3.4.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartICS v2.3.4.0 does not neutralize user-controllable input, which allows an authenticated user to inject arbitrary code into specific parameters."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-79: Cross-site Scripting"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released Version 2.4 to address these vulnerabilities and recommends users update to the newest version. Users can obtain the new version on request on the official SmartICS website https://smartics.io/"
              }
            ],
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-2140",
        "datePublished": "2022-06-27T16:14:48.000Z",
        "dateReserved": "2022-06-20T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:51:46.939Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-2088 (GCVE-0-2022-2088)

    Vulnerability from cvelistv5 – Published: 2022-06-27 16:14 – Updated: 2025-04-16 16:15
    VLAI
    Title
    Elcomplus SmartICS Access Control
    Summary
    An authenticated user with admin privileges may be able to terminate any process on the system running Elcomplus SmartICS v2.3.4.0.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    Elcomplus SmartICS Affected: v2.3.4.0
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T00:24:44.271Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-2088",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:51:23.100138Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:15:53.017Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartICS",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "v2.3.4.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An authenticated user with admin privileges may be able to terminate any process on the system running Elcomplus SmartICS v2.3.4.0."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-27T16:14:07.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released Version 2.4 to address these vulnerabilities and recommends users update to the newest version. Users can obtain the new version on request on the official SmartICS website https://smartics.io/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Elcomplus SmartICS Access Control",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2022-2088",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartICS Access Control"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartICS",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "v2.3.4.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An authenticated user with admin privileges may be able to terminate any process on the system running Elcomplus SmartICS v2.3.4.0."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-284: Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-05"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released Version 2.4 to address these vulnerabilities and recommends users update to the newest version. Users can obtain the new version on request on the official SmartICS website https://smartics.io/"
              }
            ],
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-2088",
        "datePublished": "2022-06-27T16:14:07.000Z",
        "dateReserved": "2022-06-15T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:15:53.017Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43938 (GCVE-0-2021-43938)

    Vulnerability from cvelistv5 – Published: 2022-04-29 15:18 – Updated: 2025-04-16 17:54
    VLAI
    Title
    Elcomplus SmartPTT SCADA Server Information Exposure
    Summary
    Elcomplus SmartPTT SCADA Server is vulnerable to an unauthenticated user can request various files from the server without any authentication or authorization.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.167Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43938",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:29:23.959570Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:54:48.244Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartPTT SCADA Server",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.4"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartPTT SCADA Server is vulnerable to an unauthenticated user can request various files from the server without any authentication or authorization."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-29T15:18:14.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-05",
            "discovery": "UNKNOWN"
          },
          "title": "Elcomplus SmartPTT SCADA Server Information Exposure",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2021-43938",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartPTT SCADA Server Information Exposure"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartPTT SCADA Server",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartPTT SCADA Server is vulnerable to an unauthenticated user can request various files from the server without any authentication or authorization."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-200 Information Exposure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-05",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43938",
        "datePublished": "2022-04-29T15:18:14.000Z",
        "dateReserved": "2021-11-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:54:48.244Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43937 (GCVE-0-2021-43937)

    Vulnerability from cvelistv5 – Published: 2022-04-29 15:17 – Updated: 2025-04-16 16:27
    VLAI
    Title
    Elcomplus SmartPTT SCADA Server Cross-site Request Forgery
    Summary
    Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.001Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43937",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:53:11.629914Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:27:36.910Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartPTT SCADA Server",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.4"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-29T15:17:35.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-05",
            "discovery": "UNKNOWN"
          },
          "title": "Elcomplus SmartPTT SCADA Server Cross-site Request Forgery",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2021-43937",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartPTT SCADA Server Cross-site Request Forgery"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartPTT SCADA Server",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-200 Information Exposure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-05"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-05",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43937",
        "datePublished": "2022-04-29T15:17:35.000Z",
        "dateReserved": "2021-11-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:27:36.910Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43939 (GCVE-0-2021-43939)

    Vulnerability from cvelistv5 – Published: 2022-04-28 14:55 – Updated: 2025-04-16 17:54
    VLAI
    Title
    Elcomplus SmartPtt Improper Authorization
    Summary
    Elcomplus SmartPTT is vulnerable when a low-authenticated user can access higher level administration authorization by issuing requests directly to the desired endpoints.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Elcomplus SmartPTT Affected: 1.1
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.163Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43939",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:29:26.986605Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:54:55.849Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartPTT",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartPTT is vulnerable when a low-authenticated user can access higher level administration authorization by issuing requests directly to the desired endpoints."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-285",
                  "description": "CWE-285 Improper Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-28T14:55:52.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-04",
            "discovery": "UNKNOWN"
          },
          "title": "Elcomplus SmartPtt Improper Authorization",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2021-43939",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartPtt Improper Authorization"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartPTT",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartPTT is vulnerable when a low-authenticated user can access higher level administration authorization by issuing requests directly to the desired endpoints."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-285 Improper Authorization"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-04",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43939",
        "datePublished": "2022-04-28T14:55:52.000Z",
        "dateReserved": "2021-11-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:54:55.849Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43932 (GCVE-0-2021-43932)

    Vulnerability from cvelistv5 – Published: 2022-04-28 14:54 – Updated: 2025-04-16 17:55
    VLAI
    Title
    Elcomplus SmartPtt Cross-site Scripting
    Summary
    Elcomplus SmartPTT is vulnerable when an attacker injects JavaScript code into a specific parameter that can executed upon accessing the dashboard or the main page.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Cross-site Scripting (XSS)
    Assigner
    References
    Impacted products
    Vendor Product Version
    Elcomplus SmartPTT Affected: 1.1
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:16.306Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43932",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:29:30.624901Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:55:04.470Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartPTT",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartPTT is vulnerable when an attacker injects JavaScript code into a specific parameter that can executed upon accessing the dashboard or the main page."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Cross-site Scripting (XSS)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-28T14:54:57.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-04",
            "discovery": "UNKNOWN"
          },
          "title": "Elcomplus SmartPtt Cross-site Scripting",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2021-43932",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartPtt Cross-site Scripting"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartPTT",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartPTT is vulnerable when an attacker injects JavaScript code into a specific parameter that can executed upon accessing the dashboard or the main page."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-79 Cross-site Scripting (XSS)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-04",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43932",
        "datePublished": "2022-04-28T14:54:57.000Z",
        "dateReserved": "2021-11-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T17:55:04.470Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43934 (GCVE-0-2021-43934)

    Vulnerability from cvelistv5 – Published: 2022-04-28 14:54 – Updated: 2025-04-16 16:27
    VLAI
    Title
    Elcomplus SmartPtt Unrestricted Upload of File with Dangerous Type
    Summary
    Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate upload requests, enabling a malicious user to potentially upload arbitrary files.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-434 - Unrestricted Upload of File with Dangerous Type
    Assigner
    References
    Impacted products
    Vendor Product Version
    Elcomplus SmartPTT Affected: 1.1
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.090Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43934",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:56:01.823973Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:27:44.690Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartPTT",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate upload requests, enabling a malicious user to potentially upload arbitrary files."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-28T14:54:20.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-04",
            "discovery": "UNKNOWN"
          },
          "title": "Elcomplus SmartPtt Unrestricted Upload of File with Dangerous Type",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2021-43934",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartPtt Unrestricted Upload of File with Dangerous Type"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartPTT",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate upload requests, enabling a malicious user to potentially upload arbitrary files."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-434 Unrestricted Upload of File with Dangerous Type"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-04",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43934",
        "datePublished": "2022-04-28T14:54:20.000Z",
        "dateReserved": "2021-11-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:27:44.690Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43930 (GCVE-0-2021-43930)

    Vulnerability from cvelistv5 – Published: 2022-04-28 14:53 – Updated: 2025-04-16 16:27
    VLAI
    Title
    Elcomplus SmartPtt Path Traversal
    Summary
    Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate download requests, enabling malicious users to perform path traversal attacks and potentially download arbitrary files from the system.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Elcomplus SmartPTT Affected: 1.1
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:16.986Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43930",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:53:15.384399Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:27:52.498Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SmartPTT",
              "vendor": "Elcomplus",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported these vulnerabilities to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate download requests, enabling malicious users to perform path traversal attacks and potentially download arbitrary files from the system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-28T14:53:29.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-04",
            "discovery": "UNKNOWN"
          },
          "title": "Elcomplus SmartPtt Path Traversal",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2021-43930",
              "STATE": "PUBLIC",
              "TITLE": "Elcomplus SmartPtt Path Traversal"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SmartPTT",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Elcomplus"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported these vulnerabilities to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate download requests, enabling malicious users to perform path traversal attacks and potentially download arbitrary files from the system."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04",
                  "refsource": "CONFIRM",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-04"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Elcomplus has released an update to fix these vulnerabilities and recommends users upgrade to Version 2.3.4 or later.\n\nFor more information, please contact Elcomplus support."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-04",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43930",
        "datePublished": "2022-04-28T14:53:29.000Z",
        "dateReserved": "2021-11-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:27:52.498Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }