ssa-868282
Vulnerability from csaf_siemens
Published
2024-07-09 00:00
Modified
2024-07-09 00:00
Summary
SSA-868282: Multiple Vulnerabilities in SINEMA Remote Connect Client before V3.2 HF1
Notes
Summary
SINEMA Remote Connect Server before V3.2 HF1 is affected by multiple vulnerabilities.
Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "SINEMA Remote Connect Server before V3.2 HF1 is affected by multiple vulnerabilities.\n\nSiemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-868282: Multiple Vulnerabilities in SINEMA Remote Connect Client before V3.2 HF1 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-868282.html" }, { "category": "self", "summary": "SSA-868282: Multiple Vulnerabilities in SINEMA Remote Connect Client before V3.2 HF1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-868282.json" }, { "category": "self", "summary": "SSA-868282: Multiple Vulnerabilities in SINEMA Remote Connect Client before V3.2 HF1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-868282.pdf" }, { "category": "self", "summary": "SSA-868282: Multiple Vulnerabilities in SINEMA Remote Connect Client before V3.2 HF1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-868282.txt" } ], "title": "SSA-868282: Multiple Vulnerabilities in SINEMA Remote Connect Client before V3.2 HF1", "tracking": { "current_release_date": "2024-07-09T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-868282", "initial_release_date": "2024-07-09T00:00:00Z", "revision_history": [ { "date": "2024-07-09T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V3.2 HF1", "product": { "name": "SINEMA Remote Connect Client", "product_id": "1" } } ], "category": "product_name", "name": "SINEMA Remote Connect Client" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-39567", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 HF1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109954687/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39567" }, { "cve": "CVE-2024-39568", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading proxy configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 HF1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109954687/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39568" }, { "cve": "CVE-2024-39569", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an administrative remote attacker running a corresponding SINEMA Remote Connect Server to execute arbitrary code with system privileges on the client system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V3.2 HF1 or later version", "product_ids": [ "1" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109954687/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-39569" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.