ssa-626856
Vulnerability from csaf_siemens
Published
2025-12-09 00:00
Modified
2025-12-09 00:00
Summary
SSA-626856: Multiple Vulnerabilities in SINEMA Remote Connect Sever Before V3.2 SP4
Notes
Summary
SINEMA Remote Connect Server Before V3.2 SP4 is affected by multiple vulnerabilities.
Siemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "SINEMA Remote Connect Server Before V3.2 SP4 is affected by multiple vulnerabilities.\n\nSiemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-626856: Multiple Vulnerabilities in SINEMA Remote Connect Sever Before V3.2 SP4 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-626856.html"
},
{
"category": "self",
"summary": "SSA-626856: Multiple Vulnerabilities in SINEMA Remote Connect Sever Before V3.2 SP4 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-626856.json"
}
],
"title": "SSA-626856: Multiple Vulnerabilities in SINEMA Remote Connect Sever Before V3.2 SP4",
"tracking": {
"current_release_date": "2025-12-09T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-626856",
"initial_release_date": "2025-12-09T00:00:00Z",
"revision_history": [
{
"date": "2025-12-09T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V3.2 SP4",
"product": {
"name": "SINEMA Remote Connect Server",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SINEMA Remote Connect Server"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-40818",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"category": "summary",
"text": "Affected applications contain private SSL/TLS keys on the server that are not properly protected allowing any user with server access to read these keys. This could allow an authenticated attacker to impersonate the server potentially enabling man-in-the-middle, traffic decryption or unauthorized access to services that trust these certificates.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2 SP4 or later version",
"product_ids": [
"1"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109995084/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-40818"
},
{
"cve": "CVE-2025-40819",
"cwe": {
"id": "CWE-863",
"name": "Incorrect Authorization"
},
"notes": [
{
"category": "summary",
"text": "Affected applications do not properly validate license restrictions against the database, allowing direct modification of the system_ticketinfo table to bypass license limitations without proper enforcement checks. This could allow with database access to circumvent licensing restrictions by directly modifying database values and potentially enabling unauthorized use beyond the permitted scope.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2 SP4 or later version",
"product_ids": [
"1"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109995084/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-40819"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…