ssa-401167
Vulnerability from csaf_siemens
Published
2022-06-14 00:00
Modified
2022-06-14 00:00
Summary
SSA-401167: Cross-site scripting Vulnerability in Teamcenter Active Workspace
Notes
Summary
Teamcenter Active Workspace is affected by a cross site scripting vulnerability. Siemens has released updates for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{
"document": {
"acknowledgments": [
{
"names": [
"Han Lee"
],
"organization": "Apple Information Security",
"summary": "reporting the vulnerability"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "Teamcenter Active Workspace is affected by a cross site scripting vulnerability. Siemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-401167: Cross-site scripting Vulnerability in Teamcenter Active Workspace - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-401167.pdf"
},
{
"category": "self",
"summary": "SSA-401167: Cross-site scripting Vulnerability in Teamcenter Active Workspace - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-401167.txt"
},
{
"category": "self",
"summary": "SSA-401167: Cross-site scripting Vulnerability in Teamcenter Active Workspace - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-401167.json"
}
],
"title": "SSA-401167: Cross-site scripting Vulnerability in Teamcenter Active Workspace",
"tracking": {
"current_release_date": "2022-06-14T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-401167",
"initial_release_date": "2022-06-14T00:00:00Z",
"revision_history": [
{
"date": "2022-06-14T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V5.2.9",
"product": {
"name": "Teamcenter Active Workspace V5.2",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Teamcenter Active Workspace V5.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V6.0.3",
"product": {
"name": "Teamcenter Active Workspace V6.0",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Teamcenter Active Workspace V6.0"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-32145",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious code by tricking users into accessing a malicious link.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"references": [
{
"summary": "CVE-2022-32145 - Teamcenter Active Workspace V5.2",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2022-32145 - Teamcenter Active Workspace V6.0",
"url": "https://support.sw.siemens.com/"
},
{
"summary": "CVE-2022-32145 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-32145.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V5.2.9 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V6.0.3 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "mitigation",
"details": "Utilize a modern web browser with integrated XSS filtering mechanisms",
"product_ids": [
"1",
"2"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2022-32145"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…