GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

GSD-2021-37203

Vulnerability from gsd - Updated: 2023-12-13 01:23
Details
A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2021-37203",
    "description": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.",
    "id": "GSD-2021-37203"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2021-37203"
      ],
      "details": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.",
      "id": "GSD-2021-37203",
      "modified": "2023-12-13T01:23:09.871291Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "productcert@siemens.com",
        "ID": "CVE-2021-37203",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "NX 1980 Series",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions \u003c V1984"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Solid Edge SE2021",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions \u003c SE2021MP8"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Siemens"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-125: Out-of-bounds Read"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf",
            "refsource": "MISC",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf"
          },
          {
            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf",
            "refsource": "MISC",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:nx_1980:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "1984",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "se2021",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-37203"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-125"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf",
              "refsource": "MISC",
              "tags": [
                "Patch",
                "Vendor Advisory"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf",
              "refsource": "MISC",
              "tags": [
                "Patch",
                "Vendor Advisory"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P",
            "version": "2.0"
          },
          "exploitabilityScore": 8.6,
          "impactScore": 4.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": true
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 1.8,
          "impactScore": 5.2
        }
      },
      "lastModifiedDate": "2021-11-18T16:08Z",
      "publishedDate": "2021-09-14T11:15Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…