Action not permitted
Modal body text goes here.
Modal Title
Modal Body
cve-2019-10915
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/109124 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf | Patch, Third Party Advisory | |
productcert@siemens.com | https://www.us-cert.gov/ics/advisories/icsa-19-253-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/109124 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf | Patch, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-253-02 | Third Party Advisory, US Government Resource |
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens AG | TIA Administrator |
Version: All versions < V1.0 SP1 Upd1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T22:40:15.369Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "name": "109124", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/109124" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "TIA Administrator", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0 SP1 Upd1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-09-24T15:35:14", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "name": "109124", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/109124" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-10915", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "TIA Administrator", "version": { "version_data": [ { "version_value": "All versions \u003c V1.0 SP1 Upd1" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "name": "109124", "refsource": "BID", "url": "http://www.securityfocus.com/bid/109124" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-10915", "datePublished": "2019-07-11T21:17:46", "dateReserved": "2019-04-08T00:00:00", "dateUpdated": "2024-08-04T22:40:15.369Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-10915\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2019-07-11T22:15:11.047\",\"lastModified\":\"2024-11-21T04:20:08.523\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en TIA Administrator (todas las versiones anteriores a V1.0 SP1 Upd1). La aplicaci\u00f3n web de configuraci\u00f3n integrada (TIA Administrator) permite ejecutar determinados comandos de la aplicaci\u00f3n sin la autenticaci\u00f3n apropiada. La vulnerabilidad podr\u00eda ser explotada por un atacante con acceso local en el sistema afectado. La explotaci\u00f3n con \u00e9xito no requiere privilegios ni interacci\u00f3n con el usuario. Un atacante podr\u00eda usar la vulnerabilidad para comprometer la confidencialidad, la integridad y la disponibilidad del sistema afectado. En el momento de la publicaci\u00f3n de asesoramiento, no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tia_administrator:1.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"3DC7C974-2812-4760-B2AE-F264AD2335A9\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinetplan:2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"77BA7DF4-7836-43FC-8163-86F0F9BC2FB7\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/109124\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-253-02\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://www.securityfocus.com/bid/109124\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-253-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
ghsa-pvc7-g7m2-hrpc
Vulnerability from github
A vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
{ "affected": [], "aliases": [ "CVE-2019-10915" ], "database_specific": { "cwe_ids": [ "CWE-306" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2019-07-11T22:15:00Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "id": "GHSA-pvc7-g7m2-hrpc", "modified": "2024-04-04T01:15:21Z", "published": "2022-05-24T16:50:11Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2019-10915" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "type": "WEB", "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02" }, { "type": "WEB", "url": "http://www.securityfocus.com/bid/109124" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
ICSA-19-192-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Joseph Bingham" ], "organization": "Tenable", "summary": "reporting this vulnerability to Siemens" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow an execution of some commands without proper authentication.", "title": "Risk evaluation" }, { "category": "other", "text": "Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nNCCIC also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and \nsolutions, please contact the Siemens ProductCERT:\n\nhttps://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-19-192-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-192-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-19-192-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-192-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-496604: SSA-721298: Missing Authentication Vulnerability in TIA Administrator (TIA Portal) - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/SSA-721298.txt" } ], "title": "Siemens TIA Administrator (TIA Portal)", "tracking": { "current_release_date": "2019-07-11T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-192-03", "initial_release_date": "2019-07-11T00:00:00.000000Z", "revision_history": [ { "date": "2019-07-11T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-19-192-03 Siemens TIA Administrator (Tia Portal)" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V1.0 SP1 Upd1", "product": { "name": "TIA Administrator: All versions \u003c V1.0 SP1 Upd1", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "TIA Administrator" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-10915", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication.", "title": "Summary" }, { "category": "summary", "text": "The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system.", "title": "Summary" }, { "category": "summary", "text": "At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/ww/en/view/114358", "url": "https://support.industry.siemens.com/cs/ww/en/view/114358" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-10915" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Restrict access to port 8888/tcp to localhost (default)", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V1.0 SP1 Upd1 - Download: https://support.industry.siemens.com/cs/ww/en/view/114358 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/114358" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u2019 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
icsa-19-253-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting this vulnerability to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow information disclosure, code execution, and denial-of-service.", "title": "Risk evaluation" }, { "category": "other", "text": "Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and \nsolutions, please contact the Siemens ProductCERT:\n\nhttps://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-19-253-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-253-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-19-253-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-253-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-496604: SSA-834884: Vulnerability in SINETPLAN - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/SSA-834884.txt" } ], "title": "Siemens SINETPLAN", "tracking": { "current_release_date": "2019-09-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-253-02", "initial_release_date": "2019-09-10T00:00:00.000000Z", "revision_history": [ { "date": "2019-09-10T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-19-253-02 Siemens SINETPLAN" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "V2.0", "product": { "name": "SINETPLAN: V2.0", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SINETPLAN" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-10915", "cwe": { "id": "CWE-285", "name": "Improper Authorization" }, "notes": [ { "category": "summary", "text": "The integrated configuration web application allows to execute certain application commands without proper authentication.", "title": "Summary" }, { "category": "summary", "text": "The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system.", "title": "Summary" }, { "category": "summary", "text": "At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/ww/en/view/114358", "url": "https://support.industry.siemens.com/cs/ww/en/view/114358" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-10915" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Restrict access to port 8888/tcp to localhost", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Install TIA Administrator V1.0 SP1 Upd1 - Download: https://support.industry.siemens.com/cs/ww/en/view/114358 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/114358" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
icsa-19-192-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Joseph Bingham" ], "organization": "Tenable", "summary": "reporting this vulnerability to Siemens" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow an execution of some commands without proper authentication.", "title": "Risk evaluation" }, { "category": "other", "text": "Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nNCCIC also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and \nsolutions, please contact the Siemens ProductCERT:\n\nhttps://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-19-192-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-192-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-19-192-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-192-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-496604: SSA-721298: Missing Authentication Vulnerability in TIA Administrator (TIA Portal) - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/SSA-721298.txt" } ], "title": "Siemens TIA Administrator (TIA Portal)", "tracking": { "current_release_date": "2019-07-11T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-192-03", "initial_release_date": "2019-07-11T00:00:00.000000Z", "revision_history": [ { "date": "2019-07-11T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-19-192-03 Siemens TIA Administrator (Tia Portal)" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V1.0 SP1 Upd1", "product": { "name": "TIA Administrator: All versions \u003c V1.0 SP1 Upd1", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "TIA Administrator" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-10915", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication.", "title": "Summary" }, { "category": "summary", "text": "The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system.", "title": "Summary" }, { "category": "summary", "text": "At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/ww/en/view/114358", "url": "https://support.industry.siemens.com/cs/ww/en/view/114358" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-10915" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Restrict access to port 8888/tcp to localhost (default)", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V1.0 SP1 Upd1 - Download: https://support.industry.siemens.com/cs/ww/en/view/114358 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/114358" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u2019 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
ICSA-19-253-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting this vulnerability to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow information disclosure, code execution, and denial-of-service.", "title": "Risk evaluation" }, { "category": "other", "text": "Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and \nsolutions, please contact the Siemens ProductCERT:\n\nhttps://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-19-253-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-253-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-19-253-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-253-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-496604: SSA-834884: Vulnerability in SINETPLAN - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/SSA-834884.txt" } ], "title": "Siemens SINETPLAN", "tracking": { "current_release_date": "2019-09-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-253-02", "initial_release_date": "2019-09-10T00:00:00.000000Z", "revision_history": [ { "date": "2019-09-10T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-19-253-02 Siemens SINETPLAN" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "V2.0", "product": { "name": "SINETPLAN: V2.0", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SINETPLAN" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-10915", "cwe": { "id": "CWE-285", "name": "Improper Authorization" }, "notes": [ { "category": "summary", "text": "The integrated configuration web application allows to execute certain application commands without proper authentication.", "title": "Summary" }, { "category": "summary", "text": "The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system.", "title": "Summary" }, { "category": "summary", "text": "At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/ww/en/view/114358", "url": "https://support.industry.siemens.com/cs/ww/en/view/114358" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-10915" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Restrict access to port 8888/tcp to localhost", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Install TIA Administrator V1.0 SP1 Upd1 - Download: https://support.industry.siemens.com/cs/ww/en/view/114358 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/114358" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.0, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
fkie_cve-2019-10915
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/109124 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf | Patch, Third Party Advisory | |
productcert@siemens.com | https://www.us-cert.gov/ics/advisories/icsa-19-253-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/109124 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf | Patch, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-253-02 | Third Party Advisory, US Government Resource |
Vendor | Product | Version | |
---|---|---|---|
siemens | tia_administrator | 1.0 | |
siemens | sinetplan | 2.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:tia_administrator:1.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "3DC7C974-2812-4760-B2AE-F264AD2335A9", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:sinetplan:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "77BA7DF4-7836-43FC-8163-86F0F9BC2FB7", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en TIA Administrator (todas las versiones anteriores a V1.0 SP1 Upd1). La aplicaci\u00f3n web de configuraci\u00f3n integrada (TIA Administrator) permite ejecutar determinados comandos de la aplicaci\u00f3n sin la autenticaci\u00f3n apropiada. La vulnerabilidad podr\u00eda ser explotada por un atacante con acceso local en el sistema afectado. La explotaci\u00f3n con \u00e9xito no requiere privilegios ni interacci\u00f3n con el usuario. Un atacante podr\u00eda usar la vulnerabilidad para comprometer la confidencialidad, la integridad y la disponibilidad del sistema afectado. En el momento de la publicaci\u00f3n de asesoramiento, no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad." } ], "id": "CVE-2019-10915", "lastModified": "2024-11-21T04:20:08.523", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-07-11T22:15:11.047", "references": [ { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/109124" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/109124" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
gsd-2019-10915
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2019-10915", "description": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "id": "GSD-2019-10915" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-10915" ], "details": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "id": "GSD-2019-10915", "modified": "2023-12-13T01:23:59.681296Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-10915", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "TIA Administrator", "version": { "version_data": [ { "version_value": "All versions \u003c V1.0 SP1 Upd1" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "name": "109124", "refsource": "BID", "url": "http://www.securityfocus.com/bid/109124" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:tia_administrator:1.0:sp1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:sinetplan:2.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-10915" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-306" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf", "refsource": "MISC", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "name": "109124", "refsource": "BID", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/109124" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf", "refsource": "CONFIRM", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02", "refsource": "MISC", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } }, "lastModifiedDate": "2020-10-02T14:29Z", "publishedDate": "2019-07-11T22:15Z" } } }
var-201907-1466
Vulnerability from variot
A vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. TIA Administrator Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SimaticWinCC (TIAPortal) is an engineering software for configuring and programming Simatic panels, Simatic industrial PCs and standard PCWinccruntime professional visualization software running WinCC RuntimeAdvanced or SCADA systems. An authentication vulnerability exists in SiemensTIAAdministrator. An attacker can exploit this issue to bypass the authentication mechanism or execute arbitrary commands. This may aid in further attacks
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1466", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinetplan", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "tia administrator", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "1.0" }, { "model": "tia administrator", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "1.0 sp1 upd1" }, { "model": "tia administrato sp1 upd1", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v1.0" }, { "model": "tia administrator", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "tia administrator sp1 upd1", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1.0" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "tia administrator", "version": "1.0" } ], "sources": [ { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "db": "CNVD", "id": "CNVD-2019-22235" }, { "db": "BID", "id": "109124" }, { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "NVD", "id": "CVE-2019-10915" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:tia_administrator", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-007049" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Joseph Bingham from Tenable.", "sources": [ { "db": "BID", "id": "109124" }, { "db": "CNNVD", "id": "CNNVD-201907-692" } ], "trust": 0.9 }, "cve": "CVE-2019-10915", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "CVE-2019-10915", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "CNVD-2019-22235", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "c0202593-9236-4865-9b2d-ebb56c677ca4", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2019-10915", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2019-10915", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-10915", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2019-10915", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-22235", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201907-692", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4", "trust": 0.2, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "db": "CNVD", "id": "CNVD-2019-22235" }, { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "CNNVD", "id": "CNNVD-201907-692" }, { "db": "NVD", "id": "CVE-2019-10915" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. TIA Administrator Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SimaticWinCC (TIAPortal) is an engineering software for configuring and programming Simatic panels, Simatic industrial PCs and standard PCWinccruntime professional visualization software running WinCC RuntimeAdvanced or SCADA systems. An authentication vulnerability exists in SiemensTIAAdministrator. \nAn attacker can exploit this issue to bypass the authentication mechanism or execute arbitrary commands. This may aid in further attacks", "sources": [ { "db": "NVD", "id": "CVE-2019-10915" }, { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "CNVD", "id": "CNVD-2019-22235" }, { "db": "BID", "id": "109124" }, { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" } ], "trust": 2.61 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-10915", "trust": 3.5 }, { "db": "SIEMENS", "id": "SSA-721298", "trust": 2.5 }, { "db": "ICS CERT", "id": "ICSA-19-253-02", "trust": 2.4 }, { "db": "BID", "id": "109124", "trust": 1.9 }, { "db": "ICS CERT", "id": "ICSA-19-192-03", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-834884", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2019-22235", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201907-692", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-007049", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2019.3444", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.2587", "trust": 0.6 }, { "db": "IVD", "id": "C0202593-9236-4865-9B2D-EBB56C677CA4", "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "db": "CNVD", "id": "CNVD-2019-22235" }, { "db": "BID", "id": "109124" }, { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "CNNVD", "id": "CNNVD-201907-692" }, { "db": "NVD", "id": "CVE-2019-10915" } ] }, "id": "VAR-201907-1466", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "db": "CNVD", "id": "CNVD-2019-22235" } ], "trust": 1.8 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "db": "CNVD", "id": "CNVD-2019-22235" } ] }, "last_update_date": "2024-11-23T22:41:26.821000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-721298", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "title": "SSA-834884", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "title": "Patch for SiemensTIAAdministrator authentication vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/168525" }, { "title": "Siemens TIA Administrator Fixes for access control error vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=95226" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-22235" }, { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "CNNVD", "id": "CNNVD-201907-692" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-306", "trust": 1.0 }, { "problemtype": "CWE-264", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "NVD", "id": "CVE-2019-10915" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "trust": 2.4, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02" }, { "trust": 2.2, "url": "http://www.securityfocus.com/bid/109124" }, { "trust": 1.7, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-192-03" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-10915" }, { "trust": 0.9, "url": "https://medium.com/tenable-techblog/nuclear-meltdown-with-critical-ics-vulnerabilities-8af3a1a13e6a" }, { "trust": 0.9, "url": "http://www.siemens.com/" }, { "trust": 0.9, "url": "https://github.com/tenable/poc/tree/master/siemens/tiaportal" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10915" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.3444/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.2587/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-22235" }, { "db": "BID", "id": "109124" }, { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "CNNVD", "id": "CNNVD-201907-692" }, { "db": "NVD", "id": "CVE-2019-10915" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "db": "CNVD", "id": "CNVD-2019-22235" }, { "db": "BID", "id": "109124" }, { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "CNNVD", "id": "CNNVD-201907-692" }, { "db": "NVD", "id": "CVE-2019-10915" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-07-12T00:00:00", "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "date": "2019-07-12T00:00:00", "db": "CNVD", "id": "CNVD-2019-22235" }, { "date": "2019-07-09T00:00:00", "db": "BID", "id": "109124" }, { "date": "2019-07-31T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "date": "2019-07-11T00:00:00", "db": "CNNVD", "id": "CNNVD-201907-692" }, { "date": "2019-07-11T22:15:11.047000", "db": "NVD", "id": "CVE-2019-10915" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-07-12T00:00:00", "db": "CNVD", "id": "CNVD-2019-22235" }, { "date": "2019-07-09T00:00:00", "db": "BID", "id": "109124" }, { "date": "2019-10-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "date": "2020-10-28T00:00:00", "db": "CNNVD", "id": "CNNVD-201907-692" }, { "date": "2024-11-21T04:20:08.523000", "db": "NVD", "id": "CVE-2019-10915" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "BID", "id": "109124" }, { "db": "CNNVD", "id": "CNNVD-201907-692" } ], "trust": 0.9 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens TIA Administrator Authentication vulnerability", "sources": [ { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "db": "CNVD", "id": "CNVD-2019-22235" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "access control error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201907-692" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.