CVE-2020-28396
Vulnerability from cvelistv5
Published
2020-12-14 21:05
Modified
2024-08-04 16:33
Severity ?
Summary
A vulnerability has been identified in SICAM A8000 CP-8000 (All versions < V16), SICAM A8000 CP-8021 (All versions < V16), SICAM A8000 CP-8022 (All versions < V16). A web server misconfiguration of the affected device can cause insecure ciphers usage by a user´s browser. An attacker in a privileged position could decrypt the communication and compromise confidentiality and integrity of the transmitted information.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:59.131Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-415783.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-062/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SICAM A8000 CP-8000",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16"
            }
          ]
        },
        {
          "product": "SICAM A8000 CP-8021",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16"
            }
          ]
        },
        {
          "product": "SICAM A8000 CP-8022",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SICAM A8000 CP-8000 (All versions \u003c V16), SICAM A8000 CP-8021 (All versions \u003c V16), SICAM A8000 CP-8022 (All versions \u003c V16). A web server misconfiguration of the affected device can cause insecure ciphers usage by a user\u00b4s browser. An attacker in a privileged position could decrypt the communication and compromise confidentiality and integrity of the transmitted information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-693",
              "description": "CWE-693: Protection Mechanism Failure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-14T17:06:09",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-415783.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-062/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-28396",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SICAM A8000 CP-8000",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SICAM A8000 CP-8021",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SICAM A8000 CP-8022",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V16"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SICAM A8000 CP-8000 (All versions \u003c V16), SICAM A8000 CP-8021 (All versions \u003c V16), SICAM A8000 CP-8022 (All versions \u003c V16). A web server misconfiguration of the affected device can cause insecure ciphers usage by a user\u00b4s browser. An attacker in a privileged position could decrypt the communication and compromise confidentiality and integrity of the transmitted information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-693: Protection Mechanism Failure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-415783.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-415783.pdf"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-062/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-062/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28396",
    "datePublished": "2020-12-14T21:05:19",
    "dateReserved": "2020-11-10T00:00:00",
    "dateUpdated": "2024-08-04T16:33:59.131Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-28396\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2020-12-14T21:15:21.067\",\"lastModified\":\"2024-11-21T05:22:43.117\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SICAM A8000 CP-8000 (All versions \u003c V16), SICAM A8000 CP-8021 (All versions \u003c V16), SICAM A8000 CP-8022 (All versions \u003c V16). A web server misconfiguration of the affected device can cause insecure ciphers usage by a user\u00b4s browser. An attacker in a privileged position could decrypt the communication and compromise confidentiality and integrity of the transmitted information.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SICAM A8000 CP-8000 (Todas las versiones anteriores a V16), SICAM A8000 CP-8021 (Todas las versiones anteriores a V16), SICAM A8000 CP-8022 (Todas las versiones anteriores a V16).\u0026#xa0;Una configuraci\u00f3n inapropiada del servidor web del dispositivo afectado puede causar un uso de cifrado no seguro por parte del navegador del usuario.\u0026#xa0;Un atacante en una posici\u00f3n privilegiada podr\u00eda descifrar la comunicaci\u00f3n y comprometer la confidencialidad e integridad de la informaci\u00f3n transmitida\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.1,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:P/I:P/A:N\",\"baseScore\":4.9,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":6.8,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-693\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-327\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sicam_a8000_cp-8000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"54920AB7-5A34-499A-BF46-11A165AE60B4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sicam_a8000_cp-8000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8DEF18ED-BF87-4CFA-A4BA-3387AC8964B3\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sicam_a8000_cp-8021_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"193BC64A-AA97-42B1-9F80-C8DB9517C0DA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sicam_a8000_cp-8021:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"65362A2F-DB6D-4D7F-87B5-10E18EE990F0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sicam_a8000_cp-8022_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"AD842813-A944-4F52-A0C8-C80FFEFF3B7E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sicam_a8000_cp-8022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"64D59FE8-03FD-4E5B-B7D2-47F31E98A187\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-415783.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-062/\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Not Applicable\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-415783.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-062/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Not Applicable\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.