Find a vulnerability
Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
73 vulnerabilities by vivotek
CVE-2026-22755 (GCVE-0-2026-22755)
Vulnerability from cvelistv5 – Published: 2026-01-13 15:12 – Updated: 2026-01-20 20:33- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
| Vendor | Product | Version | |
|---|---|---|---|
| Vivotek | Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 |
Affected:
0100a
(custom)
Affected: 0106a (custom) Affected: 0106b (custom) Affected: 0107a (custom) Affected: 0107b_1 (custom) Affected: 0109a (custom) Affected: 0112a (custom) Affected: 0113a (custom) Affected: 0113d (custom) Affected: 0117b (custom) Affected: 0119e (custom) Affected: 0120b (custom) Affected: 0121 (custom) Affected: 0121d (custom) Affected: 0121d_48573_1 (custom) Affected: 0122e (custom) Affected: 0124d_48573_1 (custom) Affected: 012501 (custom) Affected: 012502 (custom) Affected: 0125c (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-22755",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-13T15:29:25.879272Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-13T15:29:57.030Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://ftpmirror.your.org/pub/misc/ftp.vivotek.com/Firmware/",
"defaultStatus": "unaffected",
"modules": [
"Firmware"
],
"product": "Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "0100a",
"versionType": "custom"
},
{
"status": "affected",
"version": "0106a",
"versionType": "custom"
},
{
"status": "affected",
"version": "0106b",
"versionType": "custom"
},
{
"status": "affected",
"version": "0107a",
"versionType": "custom"
},
{
"status": "affected",
"version": "0107b_1",
"versionType": "custom"
},
{
"status": "affected",
"version": "0109a",
"versionType": "custom"
},
{
"status": "affected",
"version": "0112a",
"versionType": "custom"
},
{
"status": "affected",
"version": "0113a",
"versionType": "custom"
},
{
"status": "affected",
"version": "0113d",
"versionType": "custom"
},
{
"status": "affected",
"version": "0117b",
"versionType": "custom"
},
{
"status": "affected",
"version": "0119e",
"versionType": "custom"
},
{
"status": "affected",
"version": "0120b",
"versionType": "custom"
},
{
"status": "affected",
"version": "0121",
"versionType": "custom"
},
{
"status": "affected",
"version": "0121d",
"versionType": "custom"
},
{
"status": "affected",
"version": "0121d_48573_1",
"versionType": "custom"
},
{
"status": "affected",
"version": "0122e",
"versionType": "custom"
},
{
"status": "affected",
"version": "0124d_48573_1",
"versionType": "custom"
},
{
"status": "affected",
"version": "012501",
"versionType": "custom"
},
{
"status": "affected",
"version": "012502",
"versionType": "custom"
},
{
"status": "affected",
"version": "0125c",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Larry W. Cashdollar"
}
],
"datePublic": "2026-01-08T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.\u003cp\u003eThis issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c.\u003c/p\u003e"
}
],
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.This issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c."
}
],
"exploits": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Not public but easy to reproduce."
}
],
"value": "Not public but easy to reproduce."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "PROOF_OF_CONCEPT",
"privilegesRequired": "NONE",
"providerUrgency": "AMBER",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/AU:Y/U:Amber",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-20T20:33:02.780Z",
"orgId": "461b2335-328f-427d-ae3d-eff7d6814455",
"shortName": "larry_cashdollar"
},
"references": [
{
"url": "http://www.vapidlabs.com/advisory.php?v=220"
},
{
"url": "https://www.akamai.com/blog/security-research/command-injection-vivotek-legacy-firmware-need-to-know"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Legacy Vivotek Camera Firmware Command Injection in upload_map.cgi",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "461b2335-328f-427d-ae3d-eff7d6814455",
"assignerShortName": "larry_cashdollar",
"cveId": "CVE-2026-22755",
"datePublished": "2026-01-13T15:12:53.126Z",
"dateReserved": "2026-01-09T14:27:11.646Z",
"dateUpdated": "2026-01-20T20:33:02.780Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-66052 (GCVE-0-2025-66052)
Vulnerability from cvelistv5 – Published: 2026-01-09 11:54 – Updated: 2026-01-09 12:51 Unsupported When Assigned- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| URL | Tags |
|---|---|
| https://cert.pl/posts/2026/01/CVE-2025-66049 | third-party-advisory |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-66052",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T12:50:56.686031Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T12:51:10.558Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "IP7137",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "0200a",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Szymon Paszun"
}
],
"datePublic": "2026-01-09T11:50:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter \"system_ntpIt\" used by \"/cgi-bin/admin/setparam.cgi\" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,\u0026nbsp;\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released."
}
],
"value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter \"system_ntpIt\" used by \"/cgi-bin/admin/setparam.cgi\" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,\u00a0\nThe vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:54:16.626Z",
"orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"shortName": "CERT-PL"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
}
],
"source": {
"discovery": "EXTERNAL"
},
"tags": [
"unsupported-when-assigned"
],
"title": "Command injection in Vivotek IP7137 cameras",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"assignerShortName": "CERT-PL",
"cveId": "CVE-2025-66052",
"datePublished": "2026-01-09T11:54:16.626Z",
"dateReserved": "2025-11-21T10:41:30.020Z",
"dateUpdated": "2026-01-09T12:51:10.558Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-66051 (GCVE-0-2025-66051)
Vulnerability from cvelistv5 – Published: 2026-01-09 11:54 – Updated: 2026-01-09 14:07 Unsupported When Assigned- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
| URL | Tags |
|---|---|
| https://cert.pl/posts/2026/01/CVE-2025-66049 | third-party-advisory |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-66051",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T14:06:46.935487Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T14:07:13.457Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "IP7137",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "0200a",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Szymon Paszun"
}
],
"datePublic": "2026-01-09T11:22:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. I\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003et is possible for an authenticated attacker to access resources beyond webroot directory using a\u0026nbsp;\u003c/span\u003edirect HTTP request. Due to\u0026nbsp;CVE-2025-66050, a password for administration panel is not set \u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eby default\u003c/span\u003e.\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released. \u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a\u00a0direct HTTP request. Due to\u00a0CVE-2025-66050, a password for administration panel is not set by default.\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
}
],
"impacts": [
{
"capecId": "CAPEC-139",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-139 Relative Path Traversal"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:54:09.170Z",
"orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"shortName": "CERT-PL"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
}
],
"source": {
"discovery": "EXTERNAL"
},
"tags": [
"unsupported-when-assigned"
],
"title": "Path traversal in Vivotek IP7137 cameras",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"assignerShortName": "CERT-PL",
"cveId": "CVE-2025-66051",
"datePublished": "2026-01-09T11:54:09.170Z",
"dateReserved": "2025-11-21T10:41:30.020Z",
"dateUpdated": "2026-01-09T14:07:13.457Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-66050 (GCVE-0-2025-66050)
Vulnerability from cvelistv5 – Published: 2026-01-09 11:53 – Updated: 2026-01-09 14:08 Unsupported When Assigned- CWE-1393 - Use of Default Password
| URL | Tags |
|---|---|
| https://cert.pl/posts/2026/01/CVE-2025-66049 | third-party-advisory |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-66050",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T14:07:49.180246Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T14:08:08.233Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "IP7137",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "0200a",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Szymon Paszun"
}
],
"datePublic": "2026-01-09T11:50:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released. \u003cbr\u003e"
}
],
"value": "Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1393",
"description": "CWE-1393 Use of Default Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:53:45.338Z",
"orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"shortName": "CERT-PL"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
}
],
"source": {
"discovery": "EXTERNAL"
},
"tags": [
"unsupported-when-assigned"
],
"title": "No password set for administrative account in Vivotek IP7137 cameras",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"assignerShortName": "CERT-PL",
"cveId": "CVE-2025-66050",
"datePublished": "2026-01-09T11:53:45.338Z",
"dateReserved": "2025-11-21T10:41:30.020Z",
"dateUpdated": "2026-01-09T14:08:08.233Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-66049 (GCVE-0-2025-66049)
Vulnerability from cvelistv5 – Published: 2026-01-09 11:53 – Updated: 2026-01-09 16:22 Unsupported When Assigned- CWE-306 - Missing Authentication for Critical Function
| URL | Tags |
|---|---|
| https://cert.pl/posts/2026/01/CVE-2025-66049 | third-party-advisory |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-66049",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T16:22:03.331793Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T16:22:19.535Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "IP7137",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "0200a",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Szymon Paszun"
}
],
"datePublic": "2026-01-09T11:50:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek\u0026nbsp;IP7137\u0026nbsp;camera with firmware version\u0026nbsp;0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera\u0027s feed, potentially compromising user privacy and security.\u0026nbsp;\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected.\u0026nbsp;\u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released.\u0026nbsp;"
}
],
"value": "Vivotek\u00a0IP7137\u00a0camera with firmware version\u00a00200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera\u0027s feed, potentially compromising user privacy and security.\u00a0\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected.\u00a0Since the product has met End-Of-Life phase, a fix is not expected to be released."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:53:41.060Z",
"orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"shortName": "CERT-PL"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
}
],
"source": {
"discovery": "EXTERNAL"
},
"tags": [
"unsupported-when-assigned"
],
"title": "Unprotected RTSP stream in Vivotek\u00a0IP7137 cameras",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"assignerShortName": "CERT-PL",
"cveId": "CVE-2025-66049",
"datePublished": "2026-01-09T11:53:41.060Z",
"dateReserved": "2025-11-21T10:41:30.019Z",
"dateUpdated": "2026-01-09T16:22:19.535Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-12592 (GCVE-0-2025-12592)
Vulnerability from cvelistv5 – Published: 2025-11-19 12:30 – Updated: 2025-11-19 16:07- CWE-1392 - CWE-1392: Use of Default Credentials
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-12592",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-19T16:07:31.532330Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-19T16:07:56.677Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://ftpmirror.your.org/pub/misc/ftp.vivotek.com/Firmware/",
"defaultStatus": "unaffected",
"modules": [
"Firmware"
],
"product": "Affected device model numbers are FD7131-VVTK,FD7131-VVTK,FD7131-VVTK,FD7141-VVTK,IP7131-VVTK,IP7133-VVTK,IP7133-VVTK,IP7133-VVTK,IP7134-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7138-VVTK,IP7142-VVTK,IP7142-VVTK,IP7151-VVTK,IP7152-VVTK,IP7153-VVTK,IP7153-VVTK,IP7154-VVTK,IP7330-VVTK,IP7330-VVTK,IP7330-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131W-VVTK,PT7135-VVTK,PT7137-TCON,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PZ7131-VVTK,PZ7131-VVTK,PZ71X1-VVTK,PZ71X1-VVTK,PZ71X2-VVTK,SD73X3-VVTK,SD73X3-VVTK,SD73X3-VVTK,TC5330-VVTK,TC5332-TCVV,TC5333-TCVV,TC5633-TCVV,TC5633-VVTK,VS7100-VVTK,VS7100-VVTK,VS7100-VVTK",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "0100b",
"versionType": "custom"
},
{
"status": "affected",
"version": "0100e"
},
{
"status": "affected",
"version": "0100e1"
},
{
"status": "affected",
"version": "0100e2"
},
{
"status": "affected",
"version": "0100f"
},
{
"status": "affected",
"version": "0100g"
},
{
"status": "affected",
"version": "0100i"
},
{
"status": "affected",
"version": "0101c"
},
{
"status": "affected",
"version": "0103c"
},
{
"status": "affected",
"version": "0199z"
},
{
"status": "affected",
"version": "0200a"
},
{
"status": "affected",
"version": "0200b"
},
{
"status": "affected",
"version": "0200c"
},
{
"status": "affected",
"version": "0200g"
},
{
"status": "affected",
"version": "0201a"
},
{
"status": "affected",
"version": "0201a1"
},
{
"status": "affected",
"version": "0201c"
},
{
"status": "affected",
"version": "0201k"
},
{
"status": "affected",
"version": "0202a"
},
{
"status": "affected",
"version": "0202b"
},
{
"status": "affected",
"version": "0203a"
},
{
"status": "affected",
"version": "0300a"
},
{
"status": "affected",
"version": "0300b"
},
{
"status": "affected",
"version": "0301b3"
},
{
"status": "affected",
"version": "0302a"
},
{
"status": "affected",
"version": "0302c"
},
{
"status": "affected",
"version": "0400a"
},
{
"status": "affected",
"version": "0400b"
},
{
"status": "affected",
"version": "0401a"
},
{
"status": "affected",
"version": "0500a"
},
{
"status": "affected",
"version": "0500b"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Larry W. Cashdollar"
}
],
"datePublic": "2025-11-02T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Legacy Vivotek Device firmware uses default credetials for the root and user login accounts."
}
],
"value": "Legacy Vivotek Device firmware uses default credetials for the root and user login accounts."
}
],
"exploits": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Public"
}
],
"value": "Public"
}
],
"impacts": [
{
"capecId": "CAPEC-70",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-70 Try Common or Default Usernames and Passwords"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "PROOF_OF_CONCEPT",
"privilegesRequired": "NONE",
"providerUrgency": "RED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/AU:Y/U:Red",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392 CWE-1392: Use of Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-19T12:30:32.854Z",
"orgId": "461b2335-328f-427d-ae3d-eff7d6814455",
"shortName": "larry_cashdollar"
},
"references": [
{
"url": "https://www.akamai.com/blog/security-research/rce-zero-day-in-legacy-vivotek-firmware"
},
{
"url": "http://www.vapidlabs.com/advisory.php?v=219"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Use of default login credentials in Legacy Vivotek Devices",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "461b2335-328f-427d-ae3d-eff7d6814455",
"assignerShortName": "larry_cashdollar",
"cveId": "CVE-2025-12592",
"datePublished": "2025-11-19T12:30:32.854Z",
"dateReserved": "2025-11-01T12:15:08.915Z",
"dateUpdated": "2025-11-19T16:07:56.677Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-3403 (GCVE-0-2025-3403)
Vulnerability from cvelistv5 – Published: 2025-04-08 03:00 – Updated: 2025-04-08 18:24| URL | Tags |
|---|---|
| https://vuldb.com/?id.303648 | vdb-entry |
| https://vuldb.com/?ctiid.303648 | signaturepermissions-required |
| https://vuldb.com/?submit.543589 | third-party-advisory |
| https://github.com/lfparizzi/CVE-VIVOTEK-ID/blob/… | exploit |
| Vendor | Product | Version | |
|---|---|---|---|
| Vivotek | NVR ND8422P |
Affected:
2.4.0.204
Affected: 3.3.0.104 Affected: 4.2.0.101 |
|
| Vivotek | NVR ND9525P |
Affected:
2.4.0.204
Affected: 3.3.0.104 Affected: 4.2.0.101 |
|
| Vivotek | NVR ND9541P |
Affected:
2.4.0.204
Affected: 3.3.0.104 Affected: 4.2.0.101 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3403",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-08T15:46:08.310718Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-08T18:24:22.074Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/lfparizzi/CVE-VIVOTEK-ID/blob/main/README.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTML Form Handler"
],
"product": "NVR ND8422P",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "2.4.0.204"
},
{
"status": "affected",
"version": "3.3.0.104"
},
{
"status": "affected",
"version": "4.2.0.101"
}
]
},
{
"modules": [
"HTML Form Handler"
],
"product": "NVR ND9525P",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "2.4.0.204"
},
{
"status": "affected",
"version": "3.3.0.104"
},
{
"status": "affected",
"version": "4.2.0.101"
}
]
},
{
"modules": [
"HTML Form Handler"
],
"product": "NVR ND9541P",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "2.4.0.204"
},
{
"status": "affected",
"version": "3.3.0.104"
},
{
"status": "affected",
"version": "4.2.0.101"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Syrtain (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Vivotek NVR ND8422P, NVR ND9525P and NVR ND9541P 2.4.0.204/3.3.0.104/4.2.0.101. It has been classified as problematic. Affected is an unknown function of the component HTML Form Handler. The manipulation leads to inclusion of sensitive information in source code. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine problematische Schwachstelle in Vivotek NVR ND8422P, NVR ND9525P and NVR ND9541P 2.4.0.204/3.3.0.104/4.2.0.101 ausgemacht. Dabei betrifft es einen unbekannter Codeteil der Komponente HTML Form Handler. Durch Manipulation mit unbekannten Daten kann eine inclusion of sensitive information in source code-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:P/I:N/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-540",
"description": "Inclusion of Sensitive Information in Source Code",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "Information Disclosure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-08T03:00:11.278Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-303648 | Vivotek NVR ND8422P/NVR ND9525P/NVR ND9541P HTML Form sensitive information in source",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.303648"
},
{
"name": "VDB-303648 | CTI Indicators (IOB, IOC, TTP)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.303648"
},
{
"name": "Submit #543589 | VIVOTEK NVR Core + 4.2.0.101 and below Cleartext Storage of Sensitive Information in GUI",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.543589"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/lfparizzi/CVE-VIVOTEK-ID/blob/main/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-04-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-04-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-04-07T12:27:05.000Z",
"value": "VulDB entry last update"
}
],
"title": "Vivotek NVR ND8422P/NVR ND9525P/NVR ND9541P HTML Form sensitive information in source"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-3403",
"datePublished": "2025-04-08T03:00:11.278Z",
"dateReserved": "2025-04-07T10:22:01.598Z",
"dateUpdated": "2025-04-08T18:24:22.074Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7443 (GCVE-0-2024-7443)
Vulnerability from cvelistv5 – Published: 2024-08-03 19:00 – Updated: 2024-08-05 18:43 Unsupported When Assigned- CWE-77 - Command Injection
| URL | Tags |
|---|---|
| https://vuldb.com/?id.273528 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.273528 | signaturepermissions-required |
| https://vuldb.com/?submit.383844 | third-party-advisory |
| https://yjz233.notion.site/vivotek-IB8367A-has-co… | broken-link |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:vivotek:ib8367a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ib8367a",
"vendor": "vivotek",
"versions": [
{
"status": "affected",
"version": "vvtk-0100b"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7443",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-05T18:41:22.552464Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-05T18:43:32.506Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "IB8367A",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "VVTK-0100b"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in Vivotek IB8367A VVTK-0100b. Affected is the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-273528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Vivotek IB8367A VVTK-0100b entdeckt. Dabei betrifft es die Funktion getenv der Datei upload_file.cgi. Mit der Manipulation des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-03T19:00:09.314Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-273528 | Vivotek IB8367A upload_file.cgi getenv command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.273528"
},
{
"name": "VDB-273528 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.273528"
},
{
"name": "Submit #383844 | vivotek IB8367A VVTK-0100b command injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.383844"
},
{
"tags": [
"broken-link"
],
"url": "https://yjz233.notion.site/vivotek-IB8367A-has-command-injection-vulnerability-in-upload_file-cgi-899e5d529fb14b4189534b2b9830bfff?pvs=4"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-08-02T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-02T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-02T23:46:28.000Z",
"value": "VulDB entry last update"
}
],
"title": "Vivotek IB8367A upload_file.cgi getenv command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7443",
"datePublished": "2024-08-03T19:00:09.314Z",
"dateReserved": "2024-08-02T21:36:43.428Z",
"dateUpdated": "2024-08-05T18:43:32.506Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7442 (GCVE-0-2024-7442)
Vulnerability from cvelistv5 – Published: 2024-08-03 18:00 – Updated: 2024-08-05 15:04 Unsupported When Assigned- CWE-77 - Command Injection
| URL | Tags |
|---|---|
| https://vuldb.com/?id.273527 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.273527 | signaturepermissions-required |
| https://vuldb.com/?submit.383843 | third-party-advisory |
| https://yjz233.notion.site/vivotek-SD9364-has-com… | broken-link |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7442",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-05T15:04:20.396388Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-05T15:04:43.133Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SD9364",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "VVTK-0103f"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical. This issue affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Vivotek SD9364 VVTK-0103f ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion getenv der Datei upload_file.cgi. Dank Manipulation des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-03T18:00:09.890Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-273527 | Vivotek SD9364 upload_file.cgi getenv command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.273527"
},
{
"name": "VDB-273527 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.273527"
},
{
"name": "Submit #383843 | vivotek SD9364 VVTK-0103f command injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.383843"
},
{
"tags": [
"broken-link"
],
"url": "https://yjz233.notion.site/vivotek-SD9364-has-command-injection-vulnerability-in-upload_file-cgi-5cef6da27b25479497dda0b73670f565?pvs=4"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-08-02T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-02T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-02T23:46:16.000Z",
"value": "VulDB entry last update"
}
],
"title": "Vivotek SD9364 upload_file.cgi getenv command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7442",
"datePublished": "2024-08-03T18:00:09.890Z",
"dateReserved": "2024-08-02T21:36:40.547Z",
"dateUpdated": "2024-08-05T15:04:43.133Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7441 (GCVE-0-2024-7441)
Vulnerability from cvelistv5 – Published: 2024-08-03 17:31 – Updated: 2024-08-07 16:24 Unsupported When Assigned- CWE-121 - Stack-based Buffer Overflow
| URL | Tags |
|---|---|
| https://vuldb.com/?id.273526 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.273526 | signaturepermissions-required |
| https://vuldb.com/?submit.383842 | third-party-advisory |
| https://yjz233.notion.site/vivotek-SD9364-has-sta… | broken-linkexploit |
| Vendor | Product | Version | |
|---|---|---|---|
| Vivotek | SD9364 |
Affected:
VVTK-0103f
|
|
| vivotek | sd9364_firmware |
Affected:
vvtk-0103f
cpe:2.3:o:vivotek:sd9364_firmware:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:vivotek:sd9364_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sd9364_firmware",
"vendor": "vivotek",
"versions": [
{
"status": "affected",
"version": "vvtk-0103f"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7441",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-07T16:17:09.130706Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-07T16:24:42.771Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "SD9364",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "VVTK-0103f"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
},
{
"lang": "de",
"value": "In Vivotek SD9364 VVTK-0103f wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Das betrifft die Funktion read der Komponente httpd. Dank der Manipulation des Arguments Content-Length mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-03T17:31:04.573Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-273526 | Vivotek SD9364 httpd read stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.273526"
},
{
"name": "VDB-273526 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.273526"
},
{
"name": "Submit #383842 | vivotek SD9364 VVTK-0103f buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.383842"
},
{
"tags": [
"broken-link",
"exploit"
],
"url": "https://yjz233.notion.site/vivotek-SD9364-has-stack-buffer-overflow-vulnerability-in-httpd-c9dabd0511d04093865d1d75110429d1?pvs=4"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-08-02T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-02T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-02T23:46:19.000Z",
"value": "VulDB entry last update"
}
],
"title": "Vivotek SD9364 httpd read stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7441",
"datePublished": "2024-08-03T17:31:04.573Z",
"dateReserved": "2024-08-02T21:36:37.042Z",
"dateUpdated": "2024-08-07T16:24:42.771Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7440 (GCVE-0-2024-7440)
Vulnerability from cvelistv5 – Published: 2024-08-03 16:31 – Updated: 2024-08-07 20:36 Unsupported When Assigned- CWE-77 - Command Injection
| URL | Tags |
|---|---|
| https://vuldb.com/?id.273525 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.273525 | signaturepermissions-required |
| https://vuldb.com/?submit.383839 | third-party-advisory |
| https://yjz233.notion.site/0213043a8c7e498a9e73a0… | broken-link |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7440",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-07T20:35:43.991104Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-07T20:36:03.492Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "CC8160",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "VVTK-0100d"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d. It has been classified as critical. This affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to initiate the attack remotely. The identifier VDB-273525 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Vivotek CC8160 VVTK-0100d ausgemacht. Sie wurde als kritisch eingestuft. Es betrifft die Funktion getenv der Datei upload_file.cgi. Durch Beeinflussen des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-03T16:31:04.256Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-273525 | Vivotek CC8160 upload_file.cgi getenv command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.273525"
},
{
"name": "VDB-273525 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.273525"
},
{
"name": "Submit #383839 | vivotek CC8160 VVTK-0100d command injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.383839"
},
{
"tags": [
"broken-link"
],
"url": "https://yjz233.notion.site/0213043a8c7e498a9e73a0b6f0fa9f29?pvs=4"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-08-02T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-02T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-02T23:46:14.000Z",
"value": "VulDB entry last update"
}
],
"title": "Vivotek CC8160 upload_file.cgi getenv command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7440",
"datePublished": "2024-08-03T16:31:04.256Z",
"dateReserved": "2024-08-02T21:36:34.385Z",
"dateUpdated": "2024-08-07T20:36:03.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7439 (GCVE-0-2024-7439)
Vulnerability from cvelistv5 – Published: 2024-08-03 16:00 – Updated: 2024-08-05 15:09 Unsupported When Assigned- CWE-121 - Stack-based Buffer Overflow
| URL | Tags |
|---|---|
| https://vuldb.com/?id.273524 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.273524 | signaturepermissions-required |
| https://vuldb.com/?submit.383830 | third-party-advisory |
| https://yjz233.notion.site/vivotek-CC8160-has-sta… | broken-linkexploit |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:vivotek:cc8160:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cc8160",
"vendor": "vivotek",
"versions": [
{
"status": "affected",
"version": "VVTK-0100d"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7439",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-05T15:07:46.604884Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-05T15:09:25.672Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "CC8160",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "VVTK-0100d"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d and classified as critical. Affected by this issue is the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-273524. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Vivotek CC8160 VVTK-0100d gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion read der Komponente httpd. Durch das Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-03T16:00:07.798Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-273524 | Vivotek CC8160 httpd read stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.273524"
},
{
"name": "VDB-273524 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.273524"
},
{
"name": "Submit #383830 | VIVOTEK CC8160 VVTK-0100d buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.383830"
},
{
"tags": [
"broken-link",
"exploit"
],
"url": "https://yjz233.notion.site/vivotek-CC8160-has-stack-buffer-overflow-vulnerability-in-httpd-8409f967d3064493b649720f36d59081?pvs=4"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-08-02T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-02T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-02T23:46:03.000Z",
"value": "VulDB entry last update"
}
],
"title": "Vivotek CC8160 httpd read stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7439",
"datePublished": "2024-08-03T16:00:07.798Z",
"dateReserved": "2024-08-02T21:36:32.099Z",
"dateUpdated": "2024-08-05T15:09:25.672Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-22755 (GCVE-0-2026-22755)
Vulnerability from nvd – Published: 2026-01-13 15:12 – Updated: 2026-01-20 20:33- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
| Vendor | Product | Version | |
|---|---|---|---|
| Vivotek | Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 |
Affected:
0100a
(custom)
Affected: 0106a (custom) Affected: 0106b (custom) Affected: 0107a (custom) Affected: 0107b_1 (custom) Affected: 0109a (custom) Affected: 0112a (custom) Affected: 0113a (custom) Affected: 0113d (custom) Affected: 0117b (custom) Affected: 0119e (custom) Affected: 0120b (custom) Affected: 0121 (custom) Affected: 0121d (custom) Affected: 0121d_48573_1 (custom) Affected: 0122e (custom) Affected: 0124d_48573_1 (custom) Affected: 012501 (custom) Affected: 012502 (custom) Affected: 0125c (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-22755",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-13T15:29:25.879272Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-13T15:29:57.030Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://ftpmirror.your.org/pub/misc/ftp.vivotek.com/Firmware/",
"defaultStatus": "unaffected",
"modules": [
"Firmware"
],
"product": "Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "0100a",
"versionType": "custom"
},
{
"status": "affected",
"version": "0106a",
"versionType": "custom"
},
{
"status": "affected",
"version": "0106b",
"versionType": "custom"
},
{
"status": "affected",
"version": "0107a",
"versionType": "custom"
},
{
"status": "affected",
"version": "0107b_1",
"versionType": "custom"
},
{
"status": "affected",
"version": "0109a",
"versionType": "custom"
},
{
"status": "affected",
"version": "0112a",
"versionType": "custom"
},
{
"status": "affected",
"version": "0113a",
"versionType": "custom"
},
{
"status": "affected",
"version": "0113d",
"versionType": "custom"
},
{
"status": "affected",
"version": "0117b",
"versionType": "custom"
},
{
"status": "affected",
"version": "0119e",
"versionType": "custom"
},
{
"status": "affected",
"version": "0120b",
"versionType": "custom"
},
{
"status": "affected",
"version": "0121",
"versionType": "custom"
},
{
"status": "affected",
"version": "0121d",
"versionType": "custom"
},
{
"status": "affected",
"version": "0121d_48573_1",
"versionType": "custom"
},
{
"status": "affected",
"version": "0122e",
"versionType": "custom"
},
{
"status": "affected",
"version": "0124d_48573_1",
"versionType": "custom"
},
{
"status": "affected",
"version": "012501",
"versionType": "custom"
},
{
"status": "affected",
"version": "012502",
"versionType": "custom"
},
{
"status": "affected",
"version": "0125c",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Larry W. Cashdollar"
}
],
"datePublic": "2026-01-08T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.\u003cp\u003eThis issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c.\u003c/p\u003e"
}
],
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.This issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c."
}
],
"exploits": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Not public but easy to reproduce."
}
],
"value": "Not public but easy to reproduce."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "PROOF_OF_CONCEPT",
"privilegesRequired": "NONE",
"providerUrgency": "AMBER",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/AU:Y/U:Amber",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-20T20:33:02.780Z",
"orgId": "461b2335-328f-427d-ae3d-eff7d6814455",
"shortName": "larry_cashdollar"
},
"references": [
{
"url": "http://www.vapidlabs.com/advisory.php?v=220"
},
{
"url": "https://www.akamai.com/blog/security-research/command-injection-vivotek-legacy-firmware-need-to-know"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Legacy Vivotek Camera Firmware Command Injection in upload_map.cgi",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "461b2335-328f-427d-ae3d-eff7d6814455",
"assignerShortName": "larry_cashdollar",
"cveId": "CVE-2026-22755",
"datePublished": "2026-01-13T15:12:53.126Z",
"dateReserved": "2026-01-09T14:27:11.646Z",
"dateUpdated": "2026-01-20T20:33:02.780Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-66052 (GCVE-0-2025-66052)
Vulnerability from nvd – Published: 2026-01-09 11:54 – Updated: 2026-01-09 12:51 Unsupported When Assigned- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| URL | Tags |
|---|---|
| https://cert.pl/posts/2026/01/CVE-2025-66049 | third-party-advisory |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-66052",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T12:50:56.686031Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T12:51:10.558Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "IP7137",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "0200a",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Szymon Paszun"
}
],
"datePublic": "2026-01-09T11:50:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter \"system_ntpIt\" used by \"/cgi-bin/admin/setparam.cgi\" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,\u0026nbsp;\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released."
}
],
"value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter \"system_ntpIt\" used by \"/cgi-bin/admin/setparam.cgi\" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,\u00a0\nThe vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:54:16.626Z",
"orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"shortName": "CERT-PL"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
}
],
"source": {
"discovery": "EXTERNAL"
},
"tags": [
"unsupported-when-assigned"
],
"title": "Command injection in Vivotek IP7137 cameras",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"assignerShortName": "CERT-PL",
"cveId": "CVE-2025-66052",
"datePublished": "2026-01-09T11:54:16.626Z",
"dateReserved": "2025-11-21T10:41:30.020Z",
"dateUpdated": "2026-01-09T12:51:10.558Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-66051 (GCVE-0-2025-66051)
Vulnerability from nvd – Published: 2026-01-09 11:54 – Updated: 2026-01-09 14:07 Unsupported When Assigned- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
| URL | Tags |
|---|---|
| https://cert.pl/posts/2026/01/CVE-2025-66049 | third-party-advisory |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-66051",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T14:06:46.935487Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T14:07:13.457Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "IP7137",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "0200a",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Szymon Paszun"
}
],
"datePublic": "2026-01-09T11:22:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. I\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003et is possible for an authenticated attacker to access resources beyond webroot directory using a\u0026nbsp;\u003c/span\u003edirect HTTP request. Due to\u0026nbsp;CVE-2025-66050, a password for administration panel is not set \u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eby default\u003c/span\u003e.\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released. \u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a\u00a0direct HTTP request. Due to\u00a0CVE-2025-66050, a password for administration panel is not set by default.\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
}
],
"impacts": [
{
"capecId": "CAPEC-139",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-139 Relative Path Traversal"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:54:09.170Z",
"orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"shortName": "CERT-PL"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
}
],
"source": {
"discovery": "EXTERNAL"
},
"tags": [
"unsupported-when-assigned"
],
"title": "Path traversal in Vivotek IP7137 cameras",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"assignerShortName": "CERT-PL",
"cveId": "CVE-2025-66051",
"datePublished": "2026-01-09T11:54:09.170Z",
"dateReserved": "2025-11-21T10:41:30.020Z",
"dateUpdated": "2026-01-09T14:07:13.457Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-66050 (GCVE-0-2025-66050)
Vulnerability from nvd – Published: 2026-01-09 11:53 – Updated: 2026-01-09 14:08 Unsupported When Assigned- CWE-1393 - Use of Default Password
| URL | Tags |
|---|---|
| https://cert.pl/posts/2026/01/CVE-2025-66049 | third-party-advisory |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-66050",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T14:07:49.180246Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T14:08:08.233Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "IP7137",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "0200a",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Szymon Paszun"
}
],
"datePublic": "2026-01-09T11:50:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released. \u003cbr\u003e"
}
],
"value": "Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1393",
"description": "CWE-1393 Use of Default Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:53:45.338Z",
"orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"shortName": "CERT-PL"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
}
],
"source": {
"discovery": "EXTERNAL"
},
"tags": [
"unsupported-when-assigned"
],
"title": "No password set for administrative account in Vivotek IP7137 cameras",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"assignerShortName": "CERT-PL",
"cveId": "CVE-2025-66050",
"datePublished": "2026-01-09T11:53:45.338Z",
"dateReserved": "2025-11-21T10:41:30.020Z",
"dateUpdated": "2026-01-09T14:08:08.233Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-66049 (GCVE-0-2025-66049)
Vulnerability from nvd – Published: 2026-01-09 11:53 – Updated: 2026-01-09 16:22 Unsupported When Assigned- CWE-306 - Missing Authentication for Critical Function
| URL | Tags |
|---|---|
| https://cert.pl/posts/2026/01/CVE-2025-66049 | third-party-advisory |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-66049",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T16:22:03.331793Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T16:22:19.535Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "IP7137",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "0200a",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Szymon Paszun"
}
],
"datePublic": "2026-01-09T11:50:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek\u0026nbsp;IP7137\u0026nbsp;camera with firmware version\u0026nbsp;0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera\u0027s feed, potentially compromising user privacy and security.\u0026nbsp;\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected.\u0026nbsp;\u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released.\u0026nbsp;"
}
],
"value": "Vivotek\u00a0IP7137\u00a0camera with firmware version\u00a00200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera\u0027s feed, potentially compromising user privacy and security.\u00a0\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected.\u00a0Since the product has met End-Of-Life phase, a fix is not expected to be released."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:53:41.060Z",
"orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"shortName": "CERT-PL"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
}
],
"source": {
"discovery": "EXTERNAL"
},
"tags": [
"unsupported-when-assigned"
],
"title": "Unprotected RTSP stream in Vivotek\u00a0IP7137 cameras",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"assignerShortName": "CERT-PL",
"cveId": "CVE-2025-66049",
"datePublished": "2026-01-09T11:53:41.060Z",
"dateReserved": "2025-11-21T10:41:30.019Z",
"dateUpdated": "2026-01-09T16:22:19.535Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-12592 (GCVE-0-2025-12592)
Vulnerability from nvd – Published: 2025-11-19 12:30 – Updated: 2025-11-19 16:07- CWE-1392 - CWE-1392: Use of Default Credentials
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-12592",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-19T16:07:31.532330Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-19T16:07:56.677Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://ftpmirror.your.org/pub/misc/ftp.vivotek.com/Firmware/",
"defaultStatus": "unaffected",
"modules": [
"Firmware"
],
"product": "Affected device model numbers are FD7131-VVTK,FD7131-VVTK,FD7131-VVTK,FD7141-VVTK,IP7131-VVTK,IP7133-VVTK,IP7133-VVTK,IP7133-VVTK,IP7134-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7138-VVTK,IP7142-VVTK,IP7142-VVTK,IP7151-VVTK,IP7152-VVTK,IP7153-VVTK,IP7153-VVTK,IP7154-VVTK,IP7330-VVTK,IP7330-VVTK,IP7330-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131W-VVTK,PT7135-VVTK,PT7137-TCON,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PZ7131-VVTK,PZ7131-VVTK,PZ71X1-VVTK,PZ71X1-VVTK,PZ71X2-VVTK,SD73X3-VVTK,SD73X3-VVTK,SD73X3-VVTK,TC5330-VVTK,TC5332-TCVV,TC5333-TCVV,TC5633-TCVV,TC5633-VVTK,VS7100-VVTK,VS7100-VVTK,VS7100-VVTK",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "0100b",
"versionType": "custom"
},
{
"status": "affected",
"version": "0100e"
},
{
"status": "affected",
"version": "0100e1"
},
{
"status": "affected",
"version": "0100e2"
},
{
"status": "affected",
"version": "0100f"
},
{
"status": "affected",
"version": "0100g"
},
{
"status": "affected",
"version": "0100i"
},
{
"status": "affected",
"version": "0101c"
},
{
"status": "affected",
"version": "0103c"
},
{
"status": "affected",
"version": "0199z"
},
{
"status": "affected",
"version": "0200a"
},
{
"status": "affected",
"version": "0200b"
},
{
"status": "affected",
"version": "0200c"
},
{
"status": "affected",
"version": "0200g"
},
{
"status": "affected",
"version": "0201a"
},
{
"status": "affected",
"version": "0201a1"
},
{
"status": "affected",
"version": "0201c"
},
{
"status": "affected",
"version": "0201k"
},
{
"status": "affected",
"version": "0202a"
},
{
"status": "affected",
"version": "0202b"
},
{
"status": "affected",
"version": "0203a"
},
{
"status": "affected",
"version": "0300a"
},
{
"status": "affected",
"version": "0300b"
},
{
"status": "affected",
"version": "0301b3"
},
{
"status": "affected",
"version": "0302a"
},
{
"status": "affected",
"version": "0302c"
},
{
"status": "affected",
"version": "0400a"
},
{
"status": "affected",
"version": "0400b"
},
{
"status": "affected",
"version": "0401a"
},
{
"status": "affected",
"version": "0500a"
},
{
"status": "affected",
"version": "0500b"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Larry W. Cashdollar"
}
],
"datePublic": "2025-11-02T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Legacy Vivotek Device firmware uses default credetials for the root and user login accounts."
}
],
"value": "Legacy Vivotek Device firmware uses default credetials for the root and user login accounts."
}
],
"exploits": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Public"
}
],
"value": "Public"
}
],
"impacts": [
{
"capecId": "CAPEC-70",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-70 Try Common or Default Usernames and Passwords"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "PROOF_OF_CONCEPT",
"privilegesRequired": "NONE",
"providerUrgency": "RED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/AU:Y/U:Red",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392 CWE-1392: Use of Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-19T12:30:32.854Z",
"orgId": "461b2335-328f-427d-ae3d-eff7d6814455",
"shortName": "larry_cashdollar"
},
"references": [
{
"url": "https://www.akamai.com/blog/security-research/rce-zero-day-in-legacy-vivotek-firmware"
},
{
"url": "http://www.vapidlabs.com/advisory.php?v=219"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Use of default login credentials in Legacy Vivotek Devices",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "461b2335-328f-427d-ae3d-eff7d6814455",
"assignerShortName": "larry_cashdollar",
"cveId": "CVE-2025-12592",
"datePublished": "2025-11-19T12:30:32.854Z",
"dateReserved": "2025-11-01T12:15:08.915Z",
"dateUpdated": "2025-11-19T16:07:56.677Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-3403 (GCVE-0-2025-3403)
Vulnerability from nvd – Published: 2025-04-08 03:00 – Updated: 2025-04-08 18:24| URL | Tags |
|---|---|
| https://vuldb.com/?id.303648 | vdb-entry |
| https://vuldb.com/?ctiid.303648 | signaturepermissions-required |
| https://vuldb.com/?submit.543589 | third-party-advisory |
| https://github.com/lfparizzi/CVE-VIVOTEK-ID/blob/… | exploit |
| Vendor | Product | Version | |
|---|---|---|---|
| Vivotek | NVR ND8422P |
Affected:
2.4.0.204
Affected: 3.3.0.104 Affected: 4.2.0.101 |
|
| Vivotek | NVR ND9525P |
Affected:
2.4.0.204
Affected: 3.3.0.104 Affected: 4.2.0.101 |
|
| Vivotek | NVR ND9541P |
Affected:
2.4.0.204
Affected: 3.3.0.104 Affected: 4.2.0.101 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3403",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-08T15:46:08.310718Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-08T18:24:22.074Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/lfparizzi/CVE-VIVOTEK-ID/blob/main/README.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTML Form Handler"
],
"product": "NVR ND8422P",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "2.4.0.204"
},
{
"status": "affected",
"version": "3.3.0.104"
},
{
"status": "affected",
"version": "4.2.0.101"
}
]
},
{
"modules": [
"HTML Form Handler"
],
"product": "NVR ND9525P",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "2.4.0.204"
},
{
"status": "affected",
"version": "3.3.0.104"
},
{
"status": "affected",
"version": "4.2.0.101"
}
]
},
{
"modules": [
"HTML Form Handler"
],
"product": "NVR ND9541P",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "2.4.0.204"
},
{
"status": "affected",
"version": "3.3.0.104"
},
{
"status": "affected",
"version": "4.2.0.101"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Syrtain (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Vivotek NVR ND8422P, NVR ND9525P and NVR ND9541P 2.4.0.204/3.3.0.104/4.2.0.101. It has been classified as problematic. Affected is an unknown function of the component HTML Form Handler. The manipulation leads to inclusion of sensitive information in source code. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine problematische Schwachstelle in Vivotek NVR ND8422P, NVR ND9525P and NVR ND9541P 2.4.0.204/3.3.0.104/4.2.0.101 ausgemacht. Dabei betrifft es einen unbekannter Codeteil der Komponente HTML Form Handler. Durch Manipulation mit unbekannten Daten kann eine inclusion of sensitive information in source code-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:P/I:N/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-540",
"description": "Inclusion of Sensitive Information in Source Code",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "Information Disclosure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-08T03:00:11.278Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-303648 | Vivotek NVR ND8422P/NVR ND9525P/NVR ND9541P HTML Form sensitive information in source",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.303648"
},
{
"name": "VDB-303648 | CTI Indicators (IOB, IOC, TTP)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.303648"
},
{
"name": "Submit #543589 | VIVOTEK NVR Core + 4.2.0.101 and below Cleartext Storage of Sensitive Information in GUI",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.543589"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/lfparizzi/CVE-VIVOTEK-ID/blob/main/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-04-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-04-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-04-07T12:27:05.000Z",
"value": "VulDB entry last update"
}
],
"title": "Vivotek NVR ND8422P/NVR ND9525P/NVR ND9541P HTML Form sensitive information in source"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-3403",
"datePublished": "2025-04-08T03:00:11.278Z",
"dateReserved": "2025-04-07T10:22:01.598Z",
"dateUpdated": "2025-04-08T18:24:22.074Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7443 (GCVE-0-2024-7443)
Vulnerability from nvd – Published: 2024-08-03 19:00 – Updated: 2024-08-05 18:43 Unsupported When Assigned- CWE-77 - Command Injection
| URL | Tags |
|---|---|
| https://vuldb.com/?id.273528 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.273528 | signaturepermissions-required |
| https://vuldb.com/?submit.383844 | third-party-advisory |
| https://yjz233.notion.site/vivotek-IB8367A-has-co… | broken-link |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:vivotek:ib8367a:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ib8367a",
"vendor": "vivotek",
"versions": [
{
"status": "affected",
"version": "vvtk-0100b"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7443",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-05T18:41:22.552464Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-05T18:43:32.506Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "IB8367A",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "VVTK-0100b"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in Vivotek IB8367A VVTK-0100b. Affected is the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-273528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Vivotek IB8367A VVTK-0100b entdeckt. Dabei betrifft es die Funktion getenv der Datei upload_file.cgi. Mit der Manipulation des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-03T19:00:09.314Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-273528 | Vivotek IB8367A upload_file.cgi getenv command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.273528"
},
{
"name": "VDB-273528 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.273528"
},
{
"name": "Submit #383844 | vivotek IB8367A VVTK-0100b command injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.383844"
},
{
"tags": [
"broken-link"
],
"url": "https://yjz233.notion.site/vivotek-IB8367A-has-command-injection-vulnerability-in-upload_file-cgi-899e5d529fb14b4189534b2b9830bfff?pvs=4"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-08-02T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-02T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-02T23:46:28.000Z",
"value": "VulDB entry last update"
}
],
"title": "Vivotek IB8367A upload_file.cgi getenv command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7443",
"datePublished": "2024-08-03T19:00:09.314Z",
"dateReserved": "2024-08-02T21:36:43.428Z",
"dateUpdated": "2024-08-05T18:43:32.506Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7442 (GCVE-0-2024-7442)
Vulnerability from nvd – Published: 2024-08-03 18:00 – Updated: 2024-08-05 15:04 Unsupported When Assigned- CWE-77 - Command Injection
| URL | Tags |
|---|---|
| https://vuldb.com/?id.273527 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.273527 | signaturepermissions-required |
| https://vuldb.com/?submit.383843 | third-party-advisory |
| https://yjz233.notion.site/vivotek-SD9364-has-com… | broken-link |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7442",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-05T15:04:20.396388Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-05T15:04:43.133Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SD9364",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "VVTK-0103f"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical. This issue affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Vivotek SD9364 VVTK-0103f ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion getenv der Datei upload_file.cgi. Dank Manipulation des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-03T18:00:09.890Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-273527 | Vivotek SD9364 upload_file.cgi getenv command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.273527"
},
{
"name": "VDB-273527 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.273527"
},
{
"name": "Submit #383843 | vivotek SD9364 VVTK-0103f command injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.383843"
},
{
"tags": [
"broken-link"
],
"url": "https://yjz233.notion.site/vivotek-SD9364-has-command-injection-vulnerability-in-upload_file-cgi-5cef6da27b25479497dda0b73670f565?pvs=4"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-08-02T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-02T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-02T23:46:16.000Z",
"value": "VulDB entry last update"
}
],
"title": "Vivotek SD9364 upload_file.cgi getenv command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7442",
"datePublished": "2024-08-03T18:00:09.890Z",
"dateReserved": "2024-08-02T21:36:40.547Z",
"dateUpdated": "2024-08-05T15:04:43.133Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7441 (GCVE-0-2024-7441)
Vulnerability from nvd – Published: 2024-08-03 17:31 – Updated: 2024-08-07 16:24 Unsupported When Assigned- CWE-121 - Stack-based Buffer Overflow
| URL | Tags |
|---|---|
| https://vuldb.com/?id.273526 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.273526 | signaturepermissions-required |
| https://vuldb.com/?submit.383842 | third-party-advisory |
| https://yjz233.notion.site/vivotek-SD9364-has-sta… | broken-linkexploit |
| Vendor | Product | Version | |
|---|---|---|---|
| Vivotek | SD9364 |
Affected:
VVTK-0103f
|
|
| vivotek | sd9364_firmware |
Affected:
vvtk-0103f
cpe:2.3:o:vivotek:sd9364_firmware:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:vivotek:sd9364_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sd9364_firmware",
"vendor": "vivotek",
"versions": [
{
"status": "affected",
"version": "vvtk-0103f"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7441",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-07T16:17:09.130706Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-07T16:24:42.771Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "SD9364",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "VVTK-0103f"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
},
{
"lang": "de",
"value": "In Vivotek SD9364 VVTK-0103f wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Das betrifft die Funktion read der Komponente httpd. Dank der Manipulation des Arguments Content-Length mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-03T17:31:04.573Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-273526 | Vivotek SD9364 httpd read stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.273526"
},
{
"name": "VDB-273526 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.273526"
},
{
"name": "Submit #383842 | vivotek SD9364 VVTK-0103f buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.383842"
},
{
"tags": [
"broken-link",
"exploit"
],
"url": "https://yjz233.notion.site/vivotek-SD9364-has-stack-buffer-overflow-vulnerability-in-httpd-c9dabd0511d04093865d1d75110429d1?pvs=4"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-08-02T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-02T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-02T23:46:19.000Z",
"value": "VulDB entry last update"
}
],
"title": "Vivotek SD9364 httpd read stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7441",
"datePublished": "2024-08-03T17:31:04.573Z",
"dateReserved": "2024-08-02T21:36:37.042Z",
"dateUpdated": "2024-08-07T16:24:42.771Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7440 (GCVE-0-2024-7440)
Vulnerability from nvd – Published: 2024-08-03 16:31 – Updated: 2024-08-07 20:36 Unsupported When Assigned- CWE-77 - Command Injection
| URL | Tags |
|---|---|
| https://vuldb.com/?id.273525 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.273525 | signaturepermissions-required |
| https://vuldb.com/?submit.383839 | third-party-advisory |
| https://yjz233.notion.site/0213043a8c7e498a9e73a0… | broken-link |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7440",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-07T20:35:43.991104Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-07T20:36:03.492Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "CC8160",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "VVTK-0100d"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d. It has been classified as critical. This affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to initiate the attack remotely. The identifier VDB-273525 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Vivotek CC8160 VVTK-0100d ausgemacht. Sie wurde als kritisch eingestuft. Es betrifft die Funktion getenv der Datei upload_file.cgi. Durch Beeinflussen des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-03T16:31:04.256Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-273525 | Vivotek CC8160 upload_file.cgi getenv command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.273525"
},
{
"name": "VDB-273525 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.273525"
},
{
"name": "Submit #383839 | vivotek CC8160 VVTK-0100d command injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.383839"
},
{
"tags": [
"broken-link"
],
"url": "https://yjz233.notion.site/0213043a8c7e498a9e73a0b6f0fa9f29?pvs=4"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-08-02T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-02T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-02T23:46:14.000Z",
"value": "VulDB entry last update"
}
],
"title": "Vivotek CC8160 upload_file.cgi getenv command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7440",
"datePublished": "2024-08-03T16:31:04.256Z",
"dateReserved": "2024-08-02T21:36:34.385Z",
"dateUpdated": "2024-08-07T20:36:03.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7439 (GCVE-0-2024-7439)
Vulnerability from nvd – Published: 2024-08-03 16:00 – Updated: 2024-08-05 15:09 Unsupported When Assigned- CWE-121 - Stack-based Buffer Overflow
| URL | Tags |
|---|---|
| https://vuldb.com/?id.273524 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.273524 | signaturepermissions-required |
| https://vuldb.com/?submit.383830 | third-party-advisory |
| https://yjz233.notion.site/vivotek-CC8160-has-sta… | broken-linkexploit |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:vivotek:cc8160:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cc8160",
"vendor": "vivotek",
"versions": [
{
"status": "affected",
"version": "VVTK-0100d"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7439",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-05T15:07:46.604884Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-05T15:09:25.672Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"httpd"
],
"product": "CC8160",
"vendor": "Vivotek",
"versions": [
{
"status": "affected",
"version": "VVTK-0100d"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jylsec (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d and classified as critical. Affected by this issue is the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-273524. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Vivotek CC8160 VVTK-0100d gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion read der Komponente httpd. Durch das Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-03T16:00:07.798Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-273524 | Vivotek CC8160 httpd read stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.273524"
},
{
"name": "VDB-273524 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.273524"
},
{
"name": "Submit #383830 | VIVOTEK CC8160 VVTK-0100d buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.383830"
},
{
"tags": [
"broken-link",
"exploit"
],
"url": "https://yjz233.notion.site/vivotek-CC8160-has-stack-buffer-overflow-vulnerability-in-httpd-8409f967d3064493b649720f36d59081?pvs=4"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2024-08-02T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-08-02T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-08-02T23:46:03.000Z",
"value": "VulDB entry last update"
}
],
"title": "Vivotek CC8160 httpd read stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7439",
"datePublished": "2024-08-03T16:00:07.798Z",
"dateReserved": "2024-08-02T21:36:32.099Z",
"dateUpdated": "2024-08-05T15:09:25.672Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
VAR-201907-1136
Vulnerability from variot - Updated: 2024-05-17 23:09Vivotek FD8136 devices allow Remote Command Injection, related to BusyBox and wget. NOTE: the vendor sent a clarification on 2019-09-17 explaining that, although this CVE was first populated in July 2019, it is a historical vulnerability that does not apply to any current or recent Vivotek hardware or firmware. Vivotek FD8136 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China's Taiwan Vivotek. There is a command injection vulnerability in VivotekFD8136. The vulnerability stems from the fact that external input data constructs executable commands, and the network system or product does not properly filter the special elements. An attacker could exploit the vulnerability to execute an illegal command
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201907-1136",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "fd8136",
"scope": "eq",
"trust": 1.0,
"vendor": "vivotek",
"version": "0301a"
},
{
"model": "network camera fd8136",
"scope": null,
"trust": 0.8,
"vendor": "vivotek",
"version": null
},
{
"model": "fd8136",
"scope": null,
"trust": 0.6,
"vendor": "vivotek",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22783"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015834"
},
{
"db": "NVD",
"id": "CVE-2018-14494"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:vivotek:fd8136_firmware:0301a:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:vivotek:fd8136:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-14494"
}
]
},
"cve": "CVE-2018-14494",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2018-14494",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-22783",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-124659",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-14494",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-14494",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2019-22783",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201907-552",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-124659",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22783"
},
{
"db": "VULHUB",
"id": "VHN-124659"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015834"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-552"
},
{
"db": "NVD",
"id": "CVE-2018-14494"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vivotek FD8136 devices allow Remote Command Injection, related to BusyBox and wget. NOTE: the vendor sent a clarification on 2019-09-17 explaining that, although this CVE was first populated in July 2019, it is a historical vulnerability that does not apply to any current or recent Vivotek hardware or firmware. Vivotek FD8136 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China\u0027s Taiwan Vivotek. There is a command injection vulnerability in VivotekFD8136. The vulnerability stems from the fact that external input data constructs executable commands, and the network system or product does not properly filter the special elements. An attacker could exploit the vulnerability to execute an illegal command",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-14494"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015834"
},
{
"db": "CNVD",
"id": "CNVD-2019-22783"
},
{
"db": "VULHUB",
"id": "VHN-124659"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-14494",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015834",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201907-552",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2019-22783",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-124659",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22783"
},
{
"db": "VULHUB",
"id": "VHN-124659"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015834"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-552"
},
{
"db": "NVD",
"id": "CVE-2018-14494"
}
]
},
"id": "VAR-201907-1136",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22783"
},
{
"db": "VULHUB",
"id": "VHN-124659"
}
],
"trust": 1.45
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22783"
}
]
},
"last_update_date": "2024-05-17T23:09:49.734000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "FD8136",
"trust": 0.8,
"url": "https://www.vivotek.com/fd8136"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-015834"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.1
},
{
"problemtype": "CWE-77",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-124659"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015834"
},
{
"db": "NVD",
"id": "CVE-2018-14494"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.vdalabs.com/2018/07/23/professional-iot-hacking-series-target-selection-firmware-analysis/"
},
{
"trust": 2.3,
"url": "https://www.vdalabs.com/2018/08/06/professional-iot-hacking-series-hunting-remote-command-injection/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-14494"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14494"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22783"
},
{
"db": "VULHUB",
"id": "VHN-124659"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015834"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-552"
},
{
"db": "NVD",
"id": "CVE-2018-14494"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-22783"
},
{
"db": "VULHUB",
"id": "VHN-124659"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015834"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-552"
},
{
"db": "NVD",
"id": "CVE-2018-14494"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-07-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-22783"
},
{
"date": "2019-07-10T00:00:00",
"db": "VULHUB",
"id": "VHN-124659"
},
{
"date": "2019-07-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-015834"
},
{
"date": "2019-07-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201907-552"
},
{
"date": "2019-07-10T13:15:10.590000",
"db": "NVD",
"id": "CVE-2018-14494"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-07-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-22783"
},
{
"date": "2020-08-24T00:00:00",
"db": "VULHUB",
"id": "VHN-124659"
},
{
"date": "2019-07-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-015834"
},
{
"date": "2020-10-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201907-552"
},
{
"date": "2024-05-17T01:23:56.227000",
"db": "NVD",
"id": "CVE-2018-14494"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201907-552"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vivotek FD8136 Command injection vulnerability in devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-015834"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201907-552"
}
],
"trust": 0.6
}
}
VAR-201907-1138
Vulnerability from variot - Updated: 2024-05-17 23:09Vivotek FD8136 devices allow remote memory corruption and remote code execution because of a stack-based buffer overflow, related to sprintf, vlocal_buff_4326, and set_getparam.cgi. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance. Vivotek FD8136 The device contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China's Taiwan Vivotek. A buffer overflow vulnerability exists in VivotekFD8136 that could allow an attacker to cause a buffer overflow or heap overflow. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201907-1138",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "fd8136",
"scope": "eq",
"trust": 1.0,
"vendor": "vivotek",
"version": "0301a"
},
{
"model": "network camera fd8136",
"scope": null,
"trust": 0.8,
"vendor": "vivotek",
"version": null
},
{
"model": "fd8136",
"scope": null,
"trust": 0.6,
"vendor": "vivotek",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22271"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015836"
},
{
"db": "NVD",
"id": "CVE-2018-14496"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:vivotek:fd8136_firmware:0301a:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:vivotek:fd8136:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-14496"
}
]
},
"cve": "CVE-2018-14496",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2018-14496",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-22271",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-124661",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-14496",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-14496",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2019-22271",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201907-555",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-124661",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22271"
},
{
"db": "VULHUB",
"id": "VHN-124661"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015836"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-555"
},
{
"db": "NVD",
"id": "CVE-2018-14496"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vivotek FD8136 devices allow remote memory corruption and remote code execution because of a stack-based buffer overflow, related to sprintf, vlocal_buff_4326, and set_getparam.cgi. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it\u0027s performance. Vivotek FD8136 The device contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China\u0027s Taiwan Vivotek. A buffer overflow vulnerability exists in VivotekFD8136 that could allow an attacker to cause a buffer overflow or heap overflow. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-14496"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015836"
},
{
"db": "CNVD",
"id": "CNVD-2019-22271"
},
{
"db": "VULHUB",
"id": "VHN-124661"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-14496",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015836",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201907-555",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2019-22271",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-124661",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22271"
},
{
"db": "VULHUB",
"id": "VHN-124661"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015836"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-555"
},
{
"db": "NVD",
"id": "CVE-2018-14496"
}
]
},
"id": "VAR-201907-1138",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22271"
},
{
"db": "VULHUB",
"id": "VHN-124661"
}
],
"trust": 1.45
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22271"
}
]
},
"last_update_date": "2024-05-17T23:09:26.724000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "FD8136",
"trust": 0.8,
"url": "https://www.vivotek.com/fd8136"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-015836"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.1
},
{
"problemtype": "CWE-119",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-124661"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015836"
},
{
"db": "NVD",
"id": "CVE-2018-14496"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "https://www.vdalabs.com/2018/07/23/professional-iot-hacking-series-target-selection-firmware-analysis/"
},
{
"trust": 2.3,
"url": "https://www.vdalabs.com/2018/11/29/professional-iot-hacking-series-hunting-remote-memory-corruption/"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-14496"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14496"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22271"
},
{
"db": "VULHUB",
"id": "VHN-124661"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015836"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-555"
},
{
"db": "NVD",
"id": "CVE-2018-14496"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-22271"
},
{
"db": "VULHUB",
"id": "VHN-124661"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015836"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-555"
},
{
"db": "NVD",
"id": "CVE-2018-14496"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-07-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-22271"
},
{
"date": "2019-07-10T00:00:00",
"db": "VULHUB",
"id": "VHN-124661"
},
{
"date": "2019-07-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-015836"
},
{
"date": "2019-07-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201907-555"
},
{
"date": "2019-07-10T14:15:10.730000",
"db": "NVD",
"id": "CVE-2018-14496"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-07-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-22271"
},
{
"date": "2020-08-24T00:00:00",
"db": "VULHUB",
"id": "VHN-124661"
},
{
"date": "2019-07-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-015836"
},
{
"date": "2020-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201907-555"
},
{
"date": "2024-05-17T01:23:56.470000",
"db": "NVD",
"id": "CVE-2018-14496"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201907-555"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vivotek FD8136 Device buffer error vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-015836"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201907-555"
}
],
"trust": 0.6
}
}
VAR-201907-1137
Vulnerability from variot - Updated: 2024-05-17 22:51Vivotek FD8136 devices allow Remote Command Injection, aka "another command injection vulnerability in our target device," a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance. This vulnerability CVE-2018-14494 Is a different vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China's Taiwan Vivotek. This vulnerability is caused by external input data constructing executable commands. The network system or product does not properly filter the special elements. Attackers can use this vulnerability to execute illegal commands
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201907-1137",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "fd8136",
"scope": "eq",
"trust": 1.0,
"vendor": "vivotek",
"version": "0301a"
},
{
"model": "network camera fd8136",
"scope": null,
"trust": 0.8,
"vendor": "vivotek",
"version": null
},
{
"model": "fd8136",
"scope": null,
"trust": 0.6,
"vendor": "vivotek",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:vivotek:fd8136_firmware:0301a:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:vivotek:fd8136:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"cve": "CVE-2018-14495",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2018-14495",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-22270",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-124660",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-14495",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-14495",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2019-22270",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201907-553",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-124660",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2018-14495",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"db": "VULHUB",
"id": "VHN-124660"
},
{
"db": "VULMON",
"id": "CVE-2018-14495"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-553"
},
{
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vivotek FD8136 devices allow Remote Command Injection, aka \"another command injection vulnerability in our target device,\" a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it\u0027s performance. This vulnerability CVE-2018-14494 Is a different vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China\u0027s Taiwan Vivotek. This vulnerability is caused by external input data constructing executable commands. The network system or product does not properly filter the special elements. Attackers can use this vulnerability to execute illegal commands",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-14495"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"db": "VULHUB",
"id": "VHN-124660"
},
{
"db": "VULMON",
"id": "CVE-2018-14495"
}
],
"trust": 2.34
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-14495",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201907-553",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2019-22270",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-124660",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2018-14495",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"db": "VULHUB",
"id": "VHN-124660"
},
{
"db": "VULMON",
"id": "CVE-2018-14495"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-553"
},
{
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"id": "VAR-201907-1137",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"db": "VULHUB",
"id": "VHN-124660"
}
],
"trust": 1.45
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22270"
}
]
},
"last_update_date": "2024-05-17T22:51:07.153000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "FD8136",
"trust": 0.8,
"url": "https://www.vivotek.com/fd8136"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.1
},
{
"problemtype": "CWE-77",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-124660"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.2,
"url": "https://www.vdalabs.com/2018/07/23/professional-iot-hacking-series-target-selection-firmware-analysis/"
},
{
"trust": 2.4,
"url": "https://www.vdalabs.com/2018/08/06/professional-iot-hacking-series-hunting-remote-command-injection/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-14495"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14495"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/78.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"db": "VULHUB",
"id": "VHN-124660"
},
{
"db": "VULMON",
"id": "CVE-2018-14495"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-553"
},
{
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"db": "VULHUB",
"id": "VHN-124660"
},
{
"db": "VULMON",
"id": "CVE-2018-14495"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-553"
},
{
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-07-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"date": "2019-07-10T00:00:00",
"db": "VULHUB",
"id": "VHN-124660"
},
{
"date": "2019-07-10T00:00:00",
"db": "VULMON",
"id": "CVE-2018-14495"
},
{
"date": "2019-07-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"date": "2019-07-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201907-553"
},
{
"date": "2019-07-10T14:15:10.637000",
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-07-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"date": "2020-08-24T00:00:00",
"db": "VULHUB",
"id": "VHN-124660"
},
{
"date": "2020-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2018-14495"
},
{
"date": "2019-07-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"date": "2020-10-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201907-553"
},
{
"date": "2024-05-17T01:23:56.370000",
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201907-553"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vivotek FD8136 Command injection vulnerability in devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201907-553"
}
],
"trust": 0.6
}
}
VAR-201809-0170
Vulnerability from variot - Updated: 2024-02-06 23:05VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi. VIVOTEK FD8177 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VIVOTEKFD8177 is a network camera product from Vivotek. A command injection vulnerability exists in versions prior to VIVOTEKFD8177XXXXXX-VVTK-xx06a
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201809-0170",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "camera",
"scope": "eq",
"trust": 1.6,
"vendor": "vivotek",
"version": null
},
{
"model": "camera",
"scope": null,
"trust": 0.8,
"vendor": "vivotek",
"version": null
},
{
"model": "fd8177 \u003cxxxxxx-vvtk-xx06a",
"scope": null,
"trust": 0.6,
"vendor": "vivotek",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06202"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010299"
},
{
"db": "CNNVD",
"id": "CNNVD-201809-207"
},
{
"db": "NVD",
"id": "CVE-2018-14771"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:vivotek:camera:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-14771"
}
]
},
"cve": "CVE-2018-14771",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2018-14771",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2019-06202",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "VHN-124964",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-14771",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-14771",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2019-06202",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201809-207",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-124964",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2018-14771",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06202"
},
{
"db": "VULHUB",
"id": "VHN-124964"
},
{
"db": "VULMON",
"id": "CVE-2018-14771"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010299"
},
{
"db": "CNNVD",
"id": "CNNVD-201809-207"
},
{
"db": "NVD",
"id": "CVE-2018-14771"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi. VIVOTEK FD8177 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VIVOTEKFD8177 is a network camera product from Vivotek. A command injection vulnerability exists in versions prior to VIVOTEKFD8177XXXXXX-VVTK-xx06a",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-14771"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010299"
},
{
"db": "CNVD",
"id": "CNVD-2019-06202"
},
{
"db": "VULHUB",
"id": "VHN-124964"
},
{
"db": "VULMON",
"id": "CVE-2018-14771"
}
],
"trust": 2.34
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-14771",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010299",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201809-207",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2019-06202",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-124964",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2018-14771",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06202"
},
{
"db": "VULHUB",
"id": "VHN-124964"
},
{
"db": "VULMON",
"id": "CVE-2018-14771"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010299"
},
{
"db": "CNNVD",
"id": "CNNVD-201809-207"
},
{
"db": "NVD",
"id": "CVE-2018-14771"
}
]
},
"id": "VAR-201809-0170",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06202"
},
{
"db": "VULHUB",
"id": "VHN-124964"
}
],
"trust": 1.6391892
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06202"
}
]
},
"last_update_date": "2024-02-06T23:05:15.846000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "VVTK-SA-2018-003",
"trust": 0.8,
"url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
},
{
"title": "Cybersecurity",
"trust": 0.8,
"url": "https://www.vivotek.com/website/support/cybersecurity/"
},
{
"title": "VIVOTEKFD8177 command to inject vulnerability patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/155263"
},
{
"title": "VIVOTEK FD8177 Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=84543"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06202"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010299"
},
{
"db": "CNNVD",
"id": "CNNVD-201809-207"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "CWE-77",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-124964"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010299"
},
{
"db": "NVD",
"id": "CVE-2018-14771"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
},
{
"trust": 1.8,
"url": "https://www.vivotek.com/website/support/cybersecurity/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14771"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-14771"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06202"
},
{
"db": "VULHUB",
"id": "VHN-124964"
},
{
"db": "VULMON",
"id": "CVE-2018-14771"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010299"
},
{
"db": "CNNVD",
"id": "CNNVD-201809-207"
},
{
"db": "NVD",
"id": "CVE-2018-14771"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-06202"
},
{
"db": "VULHUB",
"id": "VHN-124964"
},
{
"db": "VULMON",
"id": "CVE-2018-14771"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010299"
},
{
"db": "CNNVD",
"id": "CNNVD-201809-207"
},
{
"db": "NVD",
"id": "CVE-2018-14771"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-03-06T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-06202"
},
{
"date": "2018-09-05T00:00:00",
"db": "VULHUB",
"id": "VHN-124964"
},
{
"date": "2018-09-05T00:00:00",
"db": "VULMON",
"id": "CVE-2018-14771"
},
{
"date": "2018-12-11T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-010299"
},
{
"date": "2018-09-06T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201809-207"
},
{
"date": "2018-09-05T21:29:00.907000",
"db": "NVD",
"id": "CVE-2018-14771"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-03-06T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-06202"
},
{
"date": "2020-08-24T00:00:00",
"db": "VULHUB",
"id": "VHN-124964"
},
{
"date": "2020-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2018-14771"
},
{
"date": "2018-12-11T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-010299"
},
{
"date": "2020-10-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201809-207"
},
{
"date": "2020-08-24T17:37:01.140000",
"db": "NVD",
"id": "CVE-2018-14771"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201809-207"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "VIVOTEK FD8177 Command Injection Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06202"
},
{
"db": "CNNVD",
"id": "CNNVD-201809-207"
}
],
"trust": 1.2
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "command injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201809-207"
}
],
"trust": 0.6
}
}
VAR-201909-1017
Vulnerability from variot - Updated: 2023-12-18 14:00VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header. VIVOTEK IP Camera The device firmware contains a classic buffer overflow vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201909-1017",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "camera",
"scope": "eq",
"trust": 1.0,
"vendor": "vivotek",
"version": null
},
{
"model": "camera",
"scope": "lt",
"trust": 0.8,
"vendor": "vivotek",
"version": "0x20x"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-009359"
},
{
"db": "NVD",
"id": "CVE-2019-14457"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:vivotek:camera:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-14457"
}
]
},
"cve": "CVE-2019-14457",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2019-14457",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-146405",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-14457",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-14457",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-201909-456",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-146405",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-146405"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009359"
},
{
"db": "NVD",
"id": "CVE-2019-14457"
},
{
"db": "CNNVD",
"id": "CNNVD-201909-456"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header. VIVOTEK IP Camera The device firmware contains a classic buffer overflow vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-14457"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009359"
},
{
"db": "VULHUB",
"id": "VHN-146405"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-14457",
"trust": 2.5
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009359",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201909-456",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-146405",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-146405"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009359"
},
{
"db": "NVD",
"id": "CVE-2019-14457"
},
{
"db": "CNNVD",
"id": "CNNVD-201909-456"
}
]
},
"id": "VAR-201909-1017",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-146405"
}
],
"trust": 0.9783784
},
"last_update_date": "2023-12-18T14:00:48.490000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "VVTK\u2212SA-2019-002",
"trust": 0.8,
"url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
},
{
"title": "VIVOTEK IP Camera Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=98049"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-009359"
},
{
"db": "CNNVD",
"id": "CNNVD-201909-456"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "CWE-120",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-146405"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009359"
},
{
"db": "NVD",
"id": "CVE-2019-14457"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-14457"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-14457"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-146405"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009359"
},
{
"db": "NVD",
"id": "CVE-2019-14457"
},
{
"db": "CNNVD",
"id": "CNNVD-201909-456"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-146405"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009359"
},
{
"db": "NVD",
"id": "CVE-2019-14457"
},
{
"db": "CNNVD",
"id": "CNNVD-201909-456"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-09-10T00:00:00",
"db": "VULHUB",
"id": "VHN-146405"
},
{
"date": "2019-09-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-009359"
},
{
"date": "2019-09-10T18:15:12.900000",
"db": "NVD",
"id": "CVE-2019-14457"
},
{
"date": "2019-09-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201909-456"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-09-16T00:00:00",
"db": "VULHUB",
"id": "VHN-146405"
},
{
"date": "2019-09-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-009359"
},
{
"date": "2021-07-21T11:39:23.747000",
"db": "NVD",
"id": "CVE-2019-14457"
},
{
"date": "2021-07-26T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201909-456"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201909-456"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "VIVOTEK IP Camera Classic buffer overflow vulnerability in device firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-009359"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201909-456"
}
],
"trust": 0.6
}
}
VAR-201706-1010
Vulnerability from variot - Updated: 2023-12-18 13:57'/cgi-bin/admin/downloadMedias.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable, which allows remote attackers to read any file on the camera's Linux filesystem via a crafted HTTP request containing ".." sequences. This vulnerability is already verified on VIVOTEK Network Camera IB8369/FD8164/FD816BA; most others have similar firmware that may be affected. VIVOTEKNetworkCameras IB8369, FD8164 and FD816BA are all network camera products of China VIVOTEK
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201706-1010",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "network camera fd816ba",
"scope": "eq",
"trust": 1.6,
"vendor": "vivotek",
"version": "fd816ba-vvtk-010101."
},
{
"model": "network camera fd8164",
"scope": "eq",
"trust": 1.6,
"vendor": "vivotek",
"version": "fd8164-_vvtk-0200b"
},
{
"model": "network camera ib8369",
"scope": "eq",
"trust": 1.6,
"vendor": "vivotek",
"version": "ib8369-vvtk-0102a"
},
{
"model": "network camera fd8164",
"scope": null,
"trust": 0.8,
"vendor": "vivotek",
"version": null
},
{
"model": "network camera fd816ba",
"scope": null,
"trust": 0.8,
"vendor": "vivotek",
"version": null
},
{
"model": "network camera ib8369",
"scope": null,
"trust": 0.8,
"vendor": "vivotek",
"version": null
},
{
"model": "ib8369",
"scope": null,
"trust": 0.6,
"vendor": "vivotek",
"version": null
},
{
"model": "fd8164",
"scope": null,
"trust": 0.6,
"vendor": "vivotek",
"version": null
},
{
"model": "fd816ba",
"scope": null,
"trust": 0.6,
"vendor": "vivotek",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-12592"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-005191"
},
{
"db": "NVD",
"id": "CVE-2017-9829"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-1060"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:vivotek:network_camera_ib8369_firmware:ib8369-vvtk-0102a:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:vivotek:network_camera_ib8369:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:vivotek:network_camera_fd8164_firmware:fd8164-_vvtk-0200b:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:vivotek:network_camera_fd8164:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:vivotek:network_camera_fd816ba_firmware:fd816ba-vvtk-010101.:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:vivotek:network_camera_fd816ba:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-9829"
}
]
},
"cve": "CVE-2017-9829",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2017-9829",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2017-12592",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-118032",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2017-9829",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-9829",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2017-12592",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201706-1060",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-118032",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-12592"
},
{
"db": "VULHUB",
"id": "VHN-118032"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-005191"
},
{
"db": "NVD",
"id": "CVE-2017-9829"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-1060"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "\u0027/cgi-bin/admin/downloadMedias.cgi\u0027 of the web service in most of the VIVOTEK Network Cameras is vulnerable, which allows remote attackers to read any file on the camera\u0027s Linux filesystem via a crafted HTTP request containing \"..\" sequences. This vulnerability is already verified on VIVOTEK Network Camera IB8369/FD8164/FD816BA; most others have similar firmware that may be affected. VIVOTEKNetworkCameras IB8369, FD8164 and FD816BA are all network camera products of China VIVOTEK",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-9829"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-005191"
},
{
"db": "CNVD",
"id": "CNVD-2017-12592"
},
{
"db": "VULHUB",
"id": "VHN-118032"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-9829",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2017-005191",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201706-1060",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2017-12592",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-118032",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-12592"
},
{
"db": "VULHUB",
"id": "VHN-118032"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-005191"
},
{
"db": "NVD",
"id": "CVE-2017-9829"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-1060"
}
]
},
"id": "VAR-201706-1010",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-12592"
},
{
"db": "VULHUB",
"id": "VHN-118032"
}
],
"trust": 1.60625
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-12592"
}
]
},
"last_update_date": "2023-12-18T13:57:18.539000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "VIVOTEK Network Cameras",
"trust": 0.8,
"url": "http://www.vivotek.com/network-cameras/#type-filter:path=default|resolution-filter:path=default|snv-filter:path=default|wdr-filter:path=default|lens-filter:path=default|ir-filter:path=default|environment-filter:path=default|views:view=jplist-grid-view"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-005191"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-22",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-118032"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-005191"
},
{
"db": "NVD",
"id": "CVE-2017-9829"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "https://blog.cal1.cn/post/an%20easy%20way%20to%20pwn%20most%20of%20the%20vivotek%20network%20cameras"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9829"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-9829"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-12592"
},
{
"db": "VULHUB",
"id": "VHN-118032"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-005191"
},
{
"db": "NVD",
"id": "CVE-2017-9829"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-1060"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2017-12592"
},
{
"db": "VULHUB",
"id": "VHN-118032"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-005191"
},
{
"db": "NVD",
"id": "CVE-2017-9829"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-1060"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-07-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-12592"
},
{
"date": "2017-06-23T00:00:00",
"db": "VULHUB",
"id": "VHN-118032"
},
{
"date": "2017-07-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-005191"
},
{
"date": "2017-06-23T22:29:00.210000",
"db": "NVD",
"id": "CVE-2017-9829"
},
{
"date": "2017-06-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201706-1060"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-07-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-12592"
},
{
"date": "2017-07-05T00:00:00",
"db": "VULHUB",
"id": "VHN-118032"
},
{
"date": "2017-07-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-005191"
},
{
"date": "2017-07-05T17:49:02.913000",
"db": "NVD",
"id": "CVE-2017-9829"
},
{
"date": "2017-06-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201706-1060"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201706-1060"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural VIVOTEK Network Camera Product Web Service of /cgi-bin/admin/downloadMedias.cgi Vulnerable to reading arbitrary files",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-005191"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "path traversal",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201706-1060"
}
],
"trust": 0.6
}
}