Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    73 vulnerabilities by vivotek

    CVE-2026-22755 (GCVE-0-2026-22755)

    Vulnerability from cvelistv5 – Published: 2026-01-13 15:12 – Updated: 2026-01-20 20:33
    VLAI
    Title
    Legacy Vivotek Camera Firmware Command Injection in upload_map.cgi
    Summary
    Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.This issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 Affected: 0100a (custom)
    Affected: 0106a (custom)
    Affected: 0106b (custom)
    Affected: 0107a (custom)
    Affected: 0107b_1 (custom)
    Affected: 0109a (custom)
    Affected: 0112a (custom)
    Affected: 0113a (custom)
    Affected: 0113d (custom)
    Affected: 0117b (custom)
    Affected: 0119e (custom)
    Affected: 0120b (custom)
    Affected: 0121 (custom)
    Affected: 0121d (custom)
    Affected: 0121d_48573_1 (custom)
    Affected: 0122e (custom)
    Affected: 0124d_48573_1 (custom)
    Affected: 012501 (custom)
    Affected: 012502 (custom)
    Affected: 0125c (custom)
    Create a notification for this product.
    Date Public
    2026-01-08 17:00
    Credits
    Larry W. Cashdollar
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22755",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-13T15:29:25.879272Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-13T15:29:57.030Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "collectionURL": "https://ftpmirror.your.org/pub/misc/ftp.vivotek.com/Firmware/",
              "defaultStatus": "unaffected",
              "modules": [
                "Firmware"
              ],
              "product": "Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0100a",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0106a",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0106b",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0107a",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0107b_1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0109a",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0112a",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0113a",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0113d",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0117b",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0119e",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0120b",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0121",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0121d",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0121d_48573_1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0122e",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0124d_48573_1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "012501",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "012502",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0125c",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Larry W. Cashdollar"
            }
          ],
          "datePublic": "2026-01-08T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.\u003cp\u003eThis issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c.\u003c/p\u003e"
                }
              ],
              "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.This issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c."
            }
          ],
          "exploits": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Not public but easy to reproduce."
                }
              ],
              "value": "Not public but easy to reproduce."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "NONE",
                "providerUrgency": "AMBER",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/AU:Y/U:Amber",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-20T20:33:02.780Z",
            "orgId": "461b2335-328f-427d-ae3d-eff7d6814455",
            "shortName": "larry_cashdollar"
          },
          "references": [
            {
              "url": "http://www.vapidlabs.com/advisory.php?v=220"
            },
            {
              "url": "https://www.akamai.com/blog/security-research/command-injection-vivotek-legacy-firmware-need-to-know"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Legacy Vivotek Camera Firmware Command Injection in upload_map.cgi",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "461b2335-328f-427d-ae3d-eff7d6814455",
        "assignerShortName": "larry_cashdollar",
        "cveId": "CVE-2026-22755",
        "datePublished": "2026-01-13T15:12:53.126Z",
        "dateReserved": "2026-01-09T14:27:11.646Z",
        "dateUpdated": "2026-01-20T20:33:02.780Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66052 (GCVE-0-2025-66052)

    Vulnerability from cvelistv5 – Published: 2026-01-09 11:54 – Updated: 2026-01-09 12:51 Unsupported When Assigned
    VLAI
    Title
    Command injection in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,  The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:50
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66052",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T12:50:56.686031Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T12:51:10.558Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter \"system_ntpIt\" used by \"/cgi-bin/admin/setparam.cgi\" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,\u0026nbsp;\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released."
                }
              ],
              "value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter \"system_ntpIt\" used by \"/cgi-bin/admin/setparam.cgi\" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,\u00a0\nThe vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:54:16.626Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Command injection in Vivotek IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66052",
        "datePublished": "2026-01-09T11:54:16.626Z",
        "dateReserved": "2025-11-21T10:41:30.020Z",
        "dateUpdated": "2026-01-09T12:51:10.558Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66051 (GCVE-0-2025-66051)

    Vulnerability from cvelistv5 – Published: 2026-01-09 11:54 – Updated: 2026-01-09 14:07 Unsupported When Assigned
    VLAI
    Title
    Path traversal in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:22
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66051",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T14:06:46.935487Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T14:07:13.457Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:22:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. I\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003et is possible for an authenticated attacker to access resources beyond webroot directory using a\u0026nbsp;\u003c/span\u003edirect HTTP request. Due to\u0026nbsp;CVE-2025-66050, a password for administration panel is not set \u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eby default\u003c/span\u003e.\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released.  \u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a\u00a0direct HTTP request. Due to\u00a0CVE-2025-66050, a password for administration panel is not set by default.\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-139",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-139 Relative Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:54:09.170Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Path traversal in Vivotek IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66051",
        "datePublished": "2026-01-09T11:54:09.170Z",
        "dateReserved": "2025-11-21T10:41:30.020Z",
        "dateUpdated": "2026-01-09T14:07:13.457Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66050 (GCVE-0-2025-66050)

    Vulnerability from cvelistv5 – Published: 2026-01-09 11:53 – Updated: 2026-01-09 14:08 Unsupported When Assigned
    VLAI
    Title
    No password set for administrative account in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:50
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66050",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T14:07:49.180246Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T14:08:08.233Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released.  \u003cbr\u003e"
                }
              ],
              "value": "Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1393",
                  "description": "CWE-1393 Use of Default Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:53:45.338Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "No password set for administrative account in Vivotek IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66050",
        "datePublished": "2026-01-09T11:53:45.338Z",
        "dateReserved": "2025-11-21T10:41:30.020Z",
        "dateUpdated": "2026-01-09T14:08:08.233Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66049 (GCVE-0-2025-66049)

    Vulnerability from cvelistv5 – Published: 2026-01-09 11:53 – Updated: 2026-01-09 16:22 Unsupported When Assigned
    VLAI
    Title
    Unprotected RTSP stream in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.  The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:50
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66049",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T16:22:03.331793Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T16:22:19.535Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek\u0026nbsp;IP7137\u0026nbsp;camera with firmware version\u0026nbsp;0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera\u0027s feed, potentially compromising user privacy and security.\u0026nbsp;\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected.\u0026nbsp;\u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released.\u0026nbsp;"
                }
              ],
              "value": "Vivotek\u00a0IP7137\u00a0camera with firmware version\u00a00200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera\u0027s feed, potentially compromising user privacy and security.\u00a0\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected.\u00a0Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:53:41.060Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Unprotected RTSP stream in Vivotek\u00a0IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66049",
        "datePublished": "2026-01-09T11:53:41.060Z",
        "dateReserved": "2025-11-21T10:41:30.019Z",
        "dateUpdated": "2026-01-09T16:22:19.535Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-12592 (GCVE-0-2025-12592)

    Vulnerability from cvelistv5 – Published: 2025-11-19 12:30 – Updated: 2025-11-19 16:07
    VLAI
    Title
    Use of default login credentials in Legacy Vivotek Devices
    Summary
    Legacy Vivotek Device firmware uses default credetials for the root and user login accounts.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-1392 - CWE-1392: Use of Default Credentials
    Assigner
    Impacted products
    Vendor Product Version
    Vivotek Affected device model numbers are FD7131-VVTK,FD7131-VVTK,FD7131-VVTK,FD7141-VVTK,IP7131-VVTK,IP7133-VVTK,IP7133-VVTK,IP7133-VVTK,IP7134-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7138-VVTK,IP7142-VVTK,IP7142-VVTK,IP7151-VVTK,IP7152-VVTK,IP7153-VVTK,IP7153-VVTK,IP7154-VVTK,IP7330-VVTK,IP7330-VVTK,IP7330-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131W-VVTK,PT7135-VVTK,PT7137-TCON,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PZ7131-VVTK,PZ7131-VVTK,PZ71X1-VVTK,PZ71X1-VVTK,PZ71X2-VVTK,SD73X3-VVTK,SD73X3-VVTK,SD73X3-VVTK,TC5330-VVTK,TC5332-TCVV,TC5333-TCVV,TC5633-TCVV,TC5633-VVTK,VS7100-VVTK,VS7100-VVTK,VS7100-VVTK Affected: 0100b (custom)
    Affected: 0100e
    Affected: 0100e1
    Affected: 0100e2
    Affected: 0100f
    Affected: 0100g
    Affected: 0100i
    Affected: 0101c
    Affected: 0103c
    Affected: 0199z
    Affected: 0200a
    Affected: 0200b
    Affected: 0200c
    Affected: 0200g
    Affected: 0201a
    Affected: 0201a1
    Affected: 0201c
    Affected: 0201k
    Affected: 0202a
    Affected: 0202b
    Affected: 0203a
    Affected: 0300a
    Affected: 0300b
    Affected: 0301b3
    Affected: 0302a
    Affected: 0302c
    Affected: 0400a
    Affected: 0400b
    Affected: 0401a
    Affected: 0500a
    Affected: 0500b
    Create a notification for this product.
    Date Public
    2025-11-02 17:00
    Credits
    Larry W. Cashdollar
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-12592",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-19T16:07:31.532330Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-19T16:07:56.677Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "collectionURL": "https://ftpmirror.your.org/pub/misc/ftp.vivotek.com/Firmware/",
              "defaultStatus": "unaffected",
              "modules": [
                "Firmware"
              ],
              "product": "Affected device model numbers are FD7131-VVTK,FD7131-VVTK,FD7131-VVTK,FD7141-VVTK,IP7131-VVTK,IP7133-VVTK,IP7133-VVTK,IP7133-VVTK,IP7134-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7138-VVTK,IP7142-VVTK,IP7142-VVTK,IP7151-VVTK,IP7152-VVTK,IP7153-VVTK,IP7153-VVTK,IP7154-VVTK,IP7330-VVTK,IP7330-VVTK,IP7330-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131W-VVTK,PT7135-VVTK,PT7137-TCON,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PZ7131-VVTK,PZ7131-VVTK,PZ71X1-VVTK,PZ71X1-VVTK,PZ71X2-VVTK,SD73X3-VVTK,SD73X3-VVTK,SD73X3-VVTK,TC5330-VVTK,TC5332-TCVV,TC5333-TCVV,TC5633-TCVV,TC5633-VVTK,VS7100-VVTK,VS7100-VVTK,VS7100-VVTK",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0100b",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0100e"
                },
                {
                  "status": "affected",
                  "version": "0100e1"
                },
                {
                  "status": "affected",
                  "version": "0100e2"
                },
                {
                  "status": "affected",
                  "version": "0100f"
                },
                {
                  "status": "affected",
                  "version": "0100g"
                },
                {
                  "status": "affected",
                  "version": "0100i"
                },
                {
                  "status": "affected",
                  "version": "0101c"
                },
                {
                  "status": "affected",
                  "version": "0103c"
                },
                {
                  "status": "affected",
                  "version": "0199z"
                },
                {
                  "status": "affected",
                  "version": "0200a"
                },
                {
                  "status": "affected",
                  "version": "0200b"
                },
                {
                  "status": "affected",
                  "version": "0200c"
                },
                {
                  "status": "affected",
                  "version": "0200g"
                },
                {
                  "status": "affected",
                  "version": "0201a"
                },
                {
                  "status": "affected",
                  "version": "0201a1"
                },
                {
                  "status": "affected",
                  "version": "0201c"
                },
                {
                  "status": "affected",
                  "version": "0201k"
                },
                {
                  "status": "affected",
                  "version": "0202a"
                },
                {
                  "status": "affected",
                  "version": "0202b"
                },
                {
                  "status": "affected",
                  "version": "0203a"
                },
                {
                  "status": "affected",
                  "version": "0300a"
                },
                {
                  "status": "affected",
                  "version": "0300b"
                },
                {
                  "status": "affected",
                  "version": "0301b3"
                },
                {
                  "status": "affected",
                  "version": "0302a"
                },
                {
                  "status": "affected",
                  "version": "0302c"
                },
                {
                  "status": "affected",
                  "version": "0400a"
                },
                {
                  "status": "affected",
                  "version": "0400b"
                },
                {
                  "status": "affected",
                  "version": "0401a"
                },
                {
                  "status": "affected",
                  "version": "0500a"
                },
                {
                  "status": "affected",
                  "version": "0500b"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Larry W. Cashdollar"
            }
          ],
          "datePublic": "2025-11-02T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Legacy Vivotek Device firmware uses default credetials for the root and user login accounts."
                }
              ],
              "value": "Legacy Vivotek Device firmware uses default credetials for the root and user login accounts."
            }
          ],
          "exploits": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Public"
                }
              ],
              "value": "Public"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-70",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-70 Try Common or Default Usernames and Passwords"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "NONE",
                "providerUrgency": "RED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/AU:Y/U:Red",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1392",
                  "description": "CWE-1392 CWE-1392: Use of Default Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-19T12:30:32.854Z",
            "orgId": "461b2335-328f-427d-ae3d-eff7d6814455",
            "shortName": "larry_cashdollar"
          },
          "references": [
            {
              "url": "https://www.akamai.com/blog/security-research/rce-zero-day-in-legacy-vivotek-firmware"
            },
            {
              "url": "http://www.vapidlabs.com/advisory.php?v=219"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Use of default login credentials in Legacy Vivotek Devices",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "461b2335-328f-427d-ae3d-eff7d6814455",
        "assignerShortName": "larry_cashdollar",
        "cveId": "CVE-2025-12592",
        "datePublished": "2025-11-19T12:30:32.854Z",
        "dateReserved": "2025-11-01T12:15:08.915Z",
        "dateUpdated": "2025-11-19T16:07:56.677Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-3403 (GCVE-0-2025-3403)

    Vulnerability from cvelistv5 – Published: 2025-04-08 03:00 – Updated: 2025-04-08 18:24
    VLAI
    Title
    Vivotek NVR ND8422P/NVR ND9525P/NVR ND9541P HTML Form sensitive information in source
    Summary
    A vulnerability was found in Vivotek NVR ND8422P, NVR ND9525P and NVR ND9541P 2.4.0.204/3.3.0.104/4.2.0.101. It has been classified as problematic. Affected is an unknown function of the component HTML Form Handler. The manipulation leads to inclusion of sensitive information in source code. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-540 - Inclusion of Sensitive Information in Source Code
    • CWE-200 - Information Disclosure
    Assigner
    References
    Impacted products
    Vendor Product Version
    Vivotek NVR ND8422P Affected: 2.4.0.204
    Affected: 3.3.0.104
    Affected: 4.2.0.101
    Create a notification for this product.
    Vivotek NVR ND9525P Affected: 2.4.0.204
    Affected: 3.3.0.104
    Affected: 4.2.0.101
    Create a notification for this product.
    Vivotek NVR ND9541P Affected: 2.4.0.204
    Affected: 3.3.0.104
    Affected: 4.2.0.101
    Create a notification for this product.
    Credits
    Syrtain (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3403",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-08T15:46:08.310718Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-08T18:24:22.074Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/lfparizzi/CVE-VIVOTEK-ID/blob/main/README.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "HTML Form Handler"
              ],
              "product": "NVR ND8422P",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.4.0.204"
                },
                {
                  "status": "affected",
                  "version": "3.3.0.104"
                },
                {
                  "status": "affected",
                  "version": "4.2.0.101"
                }
              ]
            },
            {
              "modules": [
                "HTML Form Handler"
              ],
              "product": "NVR ND9525P",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.4.0.204"
                },
                {
                  "status": "affected",
                  "version": "3.3.0.104"
                },
                {
                  "status": "affected",
                  "version": "4.2.0.101"
                }
              ]
            },
            {
              "modules": [
                "HTML Form Handler"
              ],
              "product": "NVR ND9541P",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.4.0.204"
                },
                {
                  "status": "affected",
                  "version": "3.3.0.104"
                },
                {
                  "status": "affected",
                  "version": "4.2.0.101"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Syrtain (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Vivotek NVR ND8422P, NVR ND9525P and NVR ND9541P 2.4.0.204/3.3.0.104/4.2.0.101. It has been classified as problematic. Affected is an unknown function of the component HTML Form Handler. The manipulation leads to inclusion of sensitive information in source code. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Es wurde eine problematische Schwachstelle in Vivotek NVR ND8422P, NVR ND9525P and NVR ND9541P 2.4.0.204/3.3.0.104/4.2.0.101 ausgemacht. Dabei betrifft es einen unbekannter Codeteil der Komponente HTML Form Handler. Durch Manipulation mit unbekannten Daten kann eine inclusion of sensitive information in source code-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 3.3,
                "vectorString": "AV:N/AC:L/Au:M/C:P/I:N/A:N",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-540",
                  "description": "Inclusion of Sensitive Information in Source Code",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "Information Disclosure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-08T03:00:11.278Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-303648 | Vivotek NVR ND8422P/NVR ND9525P/NVR ND9541P HTML Form sensitive information in source",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.303648"
            },
            {
              "name": "VDB-303648 | CTI Indicators (IOB, IOC, TTP)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.303648"
            },
            {
              "name": "Submit #543589 | VIVOTEK NVR Core + 4.2.0.101 and below Cleartext Storage of Sensitive Information in GUI",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.543589"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/lfparizzi/CVE-VIVOTEK-ID/blob/main/README.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-04-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-04-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-04-07T12:27:05.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Vivotek NVR ND8422P/NVR ND9525P/NVR ND9541P HTML Form sensitive information in source"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-3403",
        "datePublished": "2025-04-08T03:00:11.278Z",
        "dateReserved": "2025-04-07T10:22:01.598Z",
        "dateUpdated": "2025-04-08T18:24:22.074Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7443 (GCVE-0-2024-7443)

    Vulnerability from cvelistv5 – Published: 2024-08-03 19:00 – Updated: 2024-08-05 18:43 Unsupported When Assigned
    VLAI
    Title
    Vivotek IB8367A upload_file.cgi getenv command injection
    Summary
    ** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in Vivotek IB8367A VVTK-0100b. Affected is the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-273528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273528 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273528 signaturepermissions-required
    https://vuldb.com/?submit.383844 third-party-advisory
    https://yjz233.notion.site/vivotek-IB8367A-has-co… broken-link
    Impacted products
    Vendor Product Version
    Vivotek IB8367A Affected: VVTK-0100b
    Create a notification for this product.
    vivotek ib8367a Affected: vvtk-0100b
        cpe:2.3:h:vivotek:ib8367a:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    jylsec (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:vivotek:ib8367a:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ib8367a",
                "vendor": "vivotek",
                "versions": [
                  {
                    "status": "affected",
                    "version": "vvtk-0100b"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7443",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-05T18:41:22.552464Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-05T18:43:32.506Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "IB8367A",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "VVTK-0100b"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jylsec (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in Vivotek IB8367A VVTK-0100b. Affected is the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-273528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
            },
            {
              "lang": "de",
              "value": "Es wurde eine kritische Schwachstelle in Vivotek IB8367A VVTK-0100b entdeckt. Dabei betrifft es die Funktion getenv der Datei upload_file.cgi. Mit der Manipulation des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-03T19:00:09.314Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273528 | Vivotek IB8367A upload_file.cgi getenv command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273528"
            },
            {
              "name": "VDB-273528 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273528"
            },
            {
              "name": "Submit #383844 | vivotek IB8367A VVTK-0100b command injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.383844"
            },
            {
              "tags": [
                "broken-link"
              ],
              "url": "https://yjz233.notion.site/vivotek-IB8367A-has-command-injection-vulnerability-in-upload_file-cgi-899e5d529fb14b4189534b2b9830bfff?pvs=4"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-02T23:46:28.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Vivotek IB8367A upload_file.cgi getenv command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7443",
        "datePublished": "2024-08-03T19:00:09.314Z",
        "dateReserved": "2024-08-02T21:36:43.428Z",
        "dateUpdated": "2024-08-05T18:43:32.506Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7442 (GCVE-0-2024-7442)

    Vulnerability from cvelistv5 – Published: 2024-08-03 18:00 – Updated: 2024-08-05 15:04 Unsupported When Assigned
    VLAI
    Title
    Vivotek SD9364 upload_file.cgi getenv command injection
    Summary
    ** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical. This issue affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273527 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273527 signaturepermissions-required
    https://vuldb.com/?submit.383843 third-party-advisory
    https://yjz233.notion.site/vivotek-SD9364-has-com… broken-link
    Impacted products
    Vendor Product Version
    Vivotek SD9364 Affected: VVTK-0103f
    Create a notification for this product.
    Credits
    jylsec (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7442",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-05T15:04:20.396388Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-05T15:04:43.133Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD9364",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "VVTK-0103f"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jylsec (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical. This issue affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Vivotek SD9364 VVTK-0103f ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion getenv der Datei upload_file.cgi. Dank Manipulation des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-03T18:00:09.890Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273527 | Vivotek SD9364 upload_file.cgi getenv command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273527"
            },
            {
              "name": "VDB-273527 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273527"
            },
            {
              "name": "Submit #383843 | vivotek SD9364 VVTK-0103f command injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.383843"
            },
            {
              "tags": [
                "broken-link"
              ],
              "url": "https://yjz233.notion.site/vivotek-SD9364-has-command-injection-vulnerability-in-upload_file-cgi-5cef6da27b25479497dda0b73670f565?pvs=4"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-02T23:46:16.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Vivotek SD9364 upload_file.cgi getenv command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7442",
        "datePublished": "2024-08-03T18:00:09.890Z",
        "dateReserved": "2024-08-02T21:36:40.547Z",
        "dateUpdated": "2024-08-05T15:04:43.133Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7441 (GCVE-0-2024-7441)

    Vulnerability from cvelistv5 – Published: 2024-08-03 17:31 – Updated: 2024-08-07 16:24 Unsupported When Assigned
    VLAI
    Title
    Vivotek SD9364 httpd read stack-based overflow
    Summary
    ** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273526 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273526 signaturepermissions-required
    https://vuldb.com/?submit.383842 third-party-advisory
    https://yjz233.notion.site/vivotek-SD9364-has-sta… broken-linkexploit
    Impacted products
    Vendor Product Version
    Vivotek SD9364 Affected: VVTK-0103f
    Create a notification for this product.
    vivotek sd9364_firmware Affected: vvtk-0103f
        cpe:2.3:o:vivotek:sd9364_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    jylsec (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:vivotek:sd9364_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sd9364_firmware",
                "vendor": "vivotek",
                "versions": [
                  {
                    "status": "affected",
                    "version": "vvtk-0103f"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7441",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-07T16:17:09.130706Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-07T16:24:42.771Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "httpd"
              ],
              "product": "SD9364",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "VVTK-0103f"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jylsec (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
            },
            {
              "lang": "de",
              "value": "In Vivotek SD9364 VVTK-0103f wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Das betrifft die Funktion read der Komponente httpd. Dank der Manipulation des Arguments Content-Length mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-03T17:31:04.573Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273526 | Vivotek SD9364 httpd read stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273526"
            },
            {
              "name": "VDB-273526 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273526"
            },
            {
              "name": "Submit #383842 | vivotek SD9364 VVTK-0103f buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.383842"
            },
            {
              "tags": [
                "broken-link",
                "exploit"
              ],
              "url": "https://yjz233.notion.site/vivotek-SD9364-has-stack-buffer-overflow-vulnerability-in-httpd-c9dabd0511d04093865d1d75110429d1?pvs=4"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-02T23:46:19.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Vivotek SD9364 httpd read stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7441",
        "datePublished": "2024-08-03T17:31:04.573Z",
        "dateReserved": "2024-08-02T21:36:37.042Z",
        "dateUpdated": "2024-08-07T16:24:42.771Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7440 (GCVE-0-2024-7440)

    Vulnerability from cvelistv5 – Published: 2024-08-03 16:31 – Updated: 2024-08-07 20:36 Unsupported When Assigned
    VLAI
    Title
    Vivotek CC8160 upload_file.cgi getenv command injection
    Summary
    ** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d. It has been classified as critical. This affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to initiate the attack remotely. The identifier VDB-273525 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273525 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273525 signaturepermissions-required
    https://vuldb.com/?submit.383839 third-party-advisory
    https://yjz233.notion.site/0213043a8c7e498a9e73a0… broken-link
    Impacted products
    Vendor Product Version
    Vivotek CC8160 Affected: VVTK-0100d
    Create a notification for this product.
    Credits
    jylsec (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7440",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-07T20:35:43.991104Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-07T20:36:03.492Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CC8160",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "VVTK-0100d"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jylsec (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d. It has been classified as critical. This affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to initiate the attack remotely. The identifier VDB-273525 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
            },
            {
              "lang": "de",
              "value": "Es wurde eine Schwachstelle in Vivotek CC8160 VVTK-0100d ausgemacht. Sie wurde als kritisch eingestuft. Es betrifft die Funktion getenv der Datei upload_file.cgi. Durch Beeinflussen des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-03T16:31:04.256Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273525 | Vivotek CC8160 upload_file.cgi getenv command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273525"
            },
            {
              "name": "VDB-273525 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273525"
            },
            {
              "name": "Submit #383839 | vivotek CC8160 VVTK-0100d command injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.383839"
            },
            {
              "tags": [
                "broken-link"
              ],
              "url": "https://yjz233.notion.site/0213043a8c7e498a9e73a0b6f0fa9f29?pvs=4"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-02T23:46:14.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Vivotek CC8160 upload_file.cgi getenv command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7440",
        "datePublished": "2024-08-03T16:31:04.256Z",
        "dateReserved": "2024-08-02T21:36:34.385Z",
        "dateUpdated": "2024-08-07T20:36:03.492Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7439 (GCVE-0-2024-7439)

    Vulnerability from cvelistv5 – Published: 2024-08-03 16:00 – Updated: 2024-08-05 15:09 Unsupported When Assigned
    VLAI
    Title
    Vivotek CC8160 httpd read stack-based overflow
    Summary
    ** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d and classified as critical. Affected by this issue is the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-273524. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273524 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273524 signaturepermissions-required
    https://vuldb.com/?submit.383830 third-party-advisory
    https://yjz233.notion.site/vivotek-CC8160-has-sta… broken-linkexploit
    Impacted products
    Vendor Product Version
    Vivotek CC8160 Affected: VVTK-0100d
    Create a notification for this product.
    vivotek cc8160 Affected: VVTK-0100d
        cpe:2.3:h:vivotek:cc8160:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    jylsec (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:vivotek:cc8160:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cc8160",
                "vendor": "vivotek",
                "versions": [
                  {
                    "status": "affected",
                    "version": "VVTK-0100d"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7439",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-05T15:07:46.604884Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-05T15:09:25.672Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "httpd"
              ],
              "product": "CC8160",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "VVTK-0100d"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jylsec (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d and classified as critical. Affected by this issue is the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-273524. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Vivotek CC8160 VVTK-0100d gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion read der Komponente httpd. Durch das Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-03T16:00:07.798Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273524 | Vivotek CC8160 httpd read stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273524"
            },
            {
              "name": "VDB-273524 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273524"
            },
            {
              "name": "Submit #383830 | VIVOTEK CC8160 VVTK-0100d buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.383830"
            },
            {
              "tags": [
                "broken-link",
                "exploit"
              ],
              "url": "https://yjz233.notion.site/vivotek-CC8160-has-stack-buffer-overflow-vulnerability-in-httpd-8409f967d3064493b649720f36d59081?pvs=4"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-02T23:46:03.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Vivotek CC8160 httpd read stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7439",
        "datePublished": "2024-08-03T16:00:07.798Z",
        "dateReserved": "2024-08-02T21:36:32.099Z",
        "dateUpdated": "2024-08-05T15:09:25.672Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-22755 (GCVE-0-2026-22755)

    Vulnerability from nvd – Published: 2026-01-13 15:12 – Updated: 2026-01-20 20:33
    VLAI
    Title
    Legacy Vivotek Camera Firmware Command Injection in upload_map.cgi
    Summary
    Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.This issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 Affected: 0100a (custom)
    Affected: 0106a (custom)
    Affected: 0106b (custom)
    Affected: 0107a (custom)
    Affected: 0107b_1 (custom)
    Affected: 0109a (custom)
    Affected: 0112a (custom)
    Affected: 0113a (custom)
    Affected: 0113d (custom)
    Affected: 0117b (custom)
    Affected: 0119e (custom)
    Affected: 0120b (custom)
    Affected: 0121 (custom)
    Affected: 0121d (custom)
    Affected: 0121d_48573_1 (custom)
    Affected: 0122e (custom)
    Affected: 0124d_48573_1 (custom)
    Affected: 012501 (custom)
    Affected: 012502 (custom)
    Affected: 0125c (custom)
    Create a notification for this product.
    Date Public
    2026-01-08 17:00
    Credits
    Larry W. Cashdollar
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22755",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-13T15:29:25.879272Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-13T15:29:57.030Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "collectionURL": "https://ftpmirror.your.org/pub/misc/ftp.vivotek.com/Firmware/",
              "defaultStatus": "unaffected",
              "modules": [
                "Firmware"
              ],
              "product": "Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0100a",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0106a",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0106b",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0107a",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0107b_1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0109a",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0112a",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0113a",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0113d",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0117b",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0119e",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0120b",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0121",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0121d",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0121d_48573_1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0122e",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0124d_48573_1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "012501",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "012502",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0125c",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Larry W. Cashdollar"
            }
          ],
          "datePublic": "2026-01-08T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.\u003cp\u003eThis issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c.\u003c/p\u003e"
                }
              ],
              "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Vivotek Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330 (Firmware modules) allows OS Command Injection.This issue affects Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330: 0100a, 0106a, 0106b, 0107a, 0107b_1, 0109a, 0112a, 0113a, 0113d, 0117b, 0119e, 0120b, 0121, 0121d, 0121d_48573_1, 0122e, 0124d_48573_1, 012501, 012502, 0125c."
            }
          ],
          "exploits": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Not public but easy to reproduce."
                }
              ],
              "value": "Not public but easy to reproduce."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "NONE",
                "providerUrgency": "AMBER",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/AU:Y/U:Amber",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-20T20:33:02.780Z",
            "orgId": "461b2335-328f-427d-ae3d-eff7d6814455",
            "shortName": "larry_cashdollar"
          },
          "references": [
            {
              "url": "http://www.vapidlabs.com/advisory.php?v=220"
            },
            {
              "url": "https://www.akamai.com/blog/security-research/command-injection-vivotek-legacy-firmware-need-to-know"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Legacy Vivotek Camera Firmware Command Injection in upload_map.cgi",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "461b2335-328f-427d-ae3d-eff7d6814455",
        "assignerShortName": "larry_cashdollar",
        "cveId": "CVE-2026-22755",
        "datePublished": "2026-01-13T15:12:53.126Z",
        "dateReserved": "2026-01-09T14:27:11.646Z",
        "dateUpdated": "2026-01-20T20:33:02.780Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66052 (GCVE-0-2025-66052)

    Vulnerability from nvd – Published: 2026-01-09 11:54 – Updated: 2026-01-09 12:51 Unsupported When Assigned
    VLAI
    Title
    Command injection in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,  The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:50
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66052",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T12:50:56.686031Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T12:51:10.558Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter \"system_ntpIt\" used by \"/cgi-bin/admin/setparam.cgi\" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,\u0026nbsp;\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released."
                }
              ],
              "value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter \"system_ntpIt\" used by \"/cgi-bin/admin/setparam.cgi\" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,\u00a0\nThe vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:54:16.626Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Command injection in Vivotek IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66052",
        "datePublished": "2026-01-09T11:54:16.626Z",
        "dateReserved": "2025-11-21T10:41:30.020Z",
        "dateUpdated": "2026-01-09T12:51:10.558Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66051 (GCVE-0-2025-66051)

    Vulnerability from nvd – Published: 2026-01-09 11:54 – Updated: 2026-01-09 14:07 Unsupported When Assigned
    VLAI
    Title
    Path traversal in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:22
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66051",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T14:06:46.935487Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T14:07:13.457Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:22:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. I\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003et is possible for an authenticated attacker to access resources beyond webroot directory using a\u0026nbsp;\u003c/span\u003edirect HTTP request. Due to\u0026nbsp;CVE-2025-66050, a password for administration panel is not set \u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eby default\u003c/span\u003e.\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released.  \u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a\u00a0direct HTTP request. Due to\u00a0CVE-2025-66050, a password for administration panel is not set by default.\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-139",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-139 Relative Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:54:09.170Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Path traversal in Vivotek IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66051",
        "datePublished": "2026-01-09T11:54:09.170Z",
        "dateReserved": "2025-11-21T10:41:30.020Z",
        "dateUpdated": "2026-01-09T14:07:13.457Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66050 (GCVE-0-2025-66050)

    Vulnerability from nvd – Published: 2026-01-09 11:53 – Updated: 2026-01-09 14:08 Unsupported When Assigned
    VLAI
    Title
    No password set for administrative account in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:50
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66050",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T14:07:49.180246Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T14:08:08.233Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected. \u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released.  \u003cbr\u003e"
                }
              ],
              "value": "Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need.\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1393",
                  "description": "CWE-1393 Use of Default Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:53:45.338Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "No password set for administrative account in Vivotek IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66050",
        "datePublished": "2026-01-09T11:53:45.338Z",
        "dateReserved": "2025-11-21T10:41:30.020Z",
        "dateUpdated": "2026-01-09T14:08:08.233Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-66049 (GCVE-0-2025-66049)

    Vulnerability from nvd – Published: 2026-01-09 11:53 – Updated: 2026-01-09 16:22 Unsupported When Assigned
    VLAI
    Title
    Unprotected RTSP stream in Vivotek IP7137 cameras
    Summary
    Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.  The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    URL Tags
    https://cert.pl/posts/2026/01/CVE-2025-66049 third-party-advisory
    Impacted products
    Vendor Product Version
    Vivotek IP7137 Affected: 0200a (custom)
    Create a notification for this product.
    Date Public
    2026-01-09 11:50
    Credits
    Szymon Paszun
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-66049",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T16:22:03.331793Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T16:22:19.535Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "IP7137",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0200a",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Szymon Paszun"
            }
          ],
          "datePublic": "2026-01-09T11:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eVivotek\u0026nbsp;IP7137\u0026nbsp;camera with firmware version\u0026nbsp;0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera\u0027s feed, potentially compromising user privacy and security.\u0026nbsp;\u003cbr\u003e\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vendor has not replied to the CNA. Possibly all firmware versions are affected.\u0026nbsp;\u003c/span\u003eSince the product has met End-Of-Life phase, a fix is not expected to be released.\u0026nbsp;"
                }
              ],
              "value": "Vivotek\u00a0IP7137\u00a0camera with firmware version\u00a00200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera\u0027s feed, potentially compromising user privacy and security.\u00a0\nThe vendor has not replied to the CNA. Possibly all firmware versions are affected.\u00a0Since the product has met End-Of-Life phase, a fix is not expected to be released."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:53:41.060Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2026/01/CVE-2025-66049"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Unprotected RTSP stream in Vivotek\u00a0IP7137 cameras",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-66049",
        "datePublished": "2026-01-09T11:53:41.060Z",
        "dateReserved": "2025-11-21T10:41:30.019Z",
        "dateUpdated": "2026-01-09T16:22:19.535Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-12592 (GCVE-0-2025-12592)

    Vulnerability from nvd – Published: 2025-11-19 12:30 – Updated: 2025-11-19 16:07
    VLAI
    Title
    Use of default login credentials in Legacy Vivotek Devices
    Summary
    Legacy Vivotek Device firmware uses default credetials for the root and user login accounts.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-1392 - CWE-1392: Use of Default Credentials
    Assigner
    Impacted products
    Vendor Product Version
    Vivotek Affected device model numbers are FD7131-VVTK,FD7131-VVTK,FD7131-VVTK,FD7141-VVTK,IP7131-VVTK,IP7133-VVTK,IP7133-VVTK,IP7133-VVTK,IP7134-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7138-VVTK,IP7142-VVTK,IP7142-VVTK,IP7151-VVTK,IP7152-VVTK,IP7153-VVTK,IP7153-VVTK,IP7154-VVTK,IP7330-VVTK,IP7330-VVTK,IP7330-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131W-VVTK,PT7135-VVTK,PT7137-TCON,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PZ7131-VVTK,PZ7131-VVTK,PZ71X1-VVTK,PZ71X1-VVTK,PZ71X2-VVTK,SD73X3-VVTK,SD73X3-VVTK,SD73X3-VVTK,TC5330-VVTK,TC5332-TCVV,TC5333-TCVV,TC5633-TCVV,TC5633-VVTK,VS7100-VVTK,VS7100-VVTK,VS7100-VVTK Affected: 0100b (custom)
    Affected: 0100e
    Affected: 0100e1
    Affected: 0100e2
    Affected: 0100f
    Affected: 0100g
    Affected: 0100i
    Affected: 0101c
    Affected: 0103c
    Affected: 0199z
    Affected: 0200a
    Affected: 0200b
    Affected: 0200c
    Affected: 0200g
    Affected: 0201a
    Affected: 0201a1
    Affected: 0201c
    Affected: 0201k
    Affected: 0202a
    Affected: 0202b
    Affected: 0203a
    Affected: 0300a
    Affected: 0300b
    Affected: 0301b3
    Affected: 0302a
    Affected: 0302c
    Affected: 0400a
    Affected: 0400b
    Affected: 0401a
    Affected: 0500a
    Affected: 0500b
    Create a notification for this product.
    Date Public
    2025-11-02 17:00
    Credits
    Larry W. Cashdollar
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-12592",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-19T16:07:31.532330Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-19T16:07:56.677Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "collectionURL": "https://ftpmirror.your.org/pub/misc/ftp.vivotek.com/Firmware/",
              "defaultStatus": "unaffected",
              "modules": [
                "Firmware"
              ],
              "product": "Affected device model numbers are FD7131-VVTK,FD7131-VVTK,FD7131-VVTK,FD7141-VVTK,IP7131-VVTK,IP7133-VVTK,IP7133-VVTK,IP7133-VVTK,IP7134-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7138-VVTK,IP7142-VVTK,IP7142-VVTK,IP7151-VVTK,IP7152-VVTK,IP7153-VVTK,IP7153-VVTK,IP7154-VVTK,IP7330-VVTK,IP7330-VVTK,IP7330-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131W-VVTK,PT7135-VVTK,PT7137-TCON,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PZ7131-VVTK,PZ7131-VVTK,PZ71X1-VVTK,PZ71X1-VVTK,PZ71X2-VVTK,SD73X3-VVTK,SD73X3-VVTK,SD73X3-VVTK,TC5330-VVTK,TC5332-TCVV,TC5333-TCVV,TC5633-TCVV,TC5633-VVTK,VS7100-VVTK,VS7100-VVTK,VS7100-VVTK",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "0100b",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "0100e"
                },
                {
                  "status": "affected",
                  "version": "0100e1"
                },
                {
                  "status": "affected",
                  "version": "0100e2"
                },
                {
                  "status": "affected",
                  "version": "0100f"
                },
                {
                  "status": "affected",
                  "version": "0100g"
                },
                {
                  "status": "affected",
                  "version": "0100i"
                },
                {
                  "status": "affected",
                  "version": "0101c"
                },
                {
                  "status": "affected",
                  "version": "0103c"
                },
                {
                  "status": "affected",
                  "version": "0199z"
                },
                {
                  "status": "affected",
                  "version": "0200a"
                },
                {
                  "status": "affected",
                  "version": "0200b"
                },
                {
                  "status": "affected",
                  "version": "0200c"
                },
                {
                  "status": "affected",
                  "version": "0200g"
                },
                {
                  "status": "affected",
                  "version": "0201a"
                },
                {
                  "status": "affected",
                  "version": "0201a1"
                },
                {
                  "status": "affected",
                  "version": "0201c"
                },
                {
                  "status": "affected",
                  "version": "0201k"
                },
                {
                  "status": "affected",
                  "version": "0202a"
                },
                {
                  "status": "affected",
                  "version": "0202b"
                },
                {
                  "status": "affected",
                  "version": "0203a"
                },
                {
                  "status": "affected",
                  "version": "0300a"
                },
                {
                  "status": "affected",
                  "version": "0300b"
                },
                {
                  "status": "affected",
                  "version": "0301b3"
                },
                {
                  "status": "affected",
                  "version": "0302a"
                },
                {
                  "status": "affected",
                  "version": "0302c"
                },
                {
                  "status": "affected",
                  "version": "0400a"
                },
                {
                  "status": "affected",
                  "version": "0400b"
                },
                {
                  "status": "affected",
                  "version": "0401a"
                },
                {
                  "status": "affected",
                  "version": "0500a"
                },
                {
                  "status": "affected",
                  "version": "0500b"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Larry W. Cashdollar"
            }
          ],
          "datePublic": "2025-11-02T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Legacy Vivotek Device firmware uses default credetials for the root and user login accounts."
                }
              ],
              "value": "Legacy Vivotek Device firmware uses default credetials for the root and user login accounts."
            }
          ],
          "exploits": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Public"
                }
              ],
              "value": "Public"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-70",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-70 Try Common or Default Usernames and Passwords"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "NONE",
                "providerUrgency": "RED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/AU:Y/U:Red",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1392",
                  "description": "CWE-1392 CWE-1392: Use of Default Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-19T12:30:32.854Z",
            "orgId": "461b2335-328f-427d-ae3d-eff7d6814455",
            "shortName": "larry_cashdollar"
          },
          "references": [
            {
              "url": "https://www.akamai.com/blog/security-research/rce-zero-day-in-legacy-vivotek-firmware"
            },
            {
              "url": "http://www.vapidlabs.com/advisory.php?v=219"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Use of default login credentials in Legacy Vivotek Devices",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "461b2335-328f-427d-ae3d-eff7d6814455",
        "assignerShortName": "larry_cashdollar",
        "cveId": "CVE-2025-12592",
        "datePublished": "2025-11-19T12:30:32.854Z",
        "dateReserved": "2025-11-01T12:15:08.915Z",
        "dateUpdated": "2025-11-19T16:07:56.677Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-3403 (GCVE-0-2025-3403)

    Vulnerability from nvd – Published: 2025-04-08 03:00 – Updated: 2025-04-08 18:24
    VLAI
    Title
    Vivotek NVR ND8422P/NVR ND9525P/NVR ND9541P HTML Form sensitive information in source
    Summary
    A vulnerability was found in Vivotek NVR ND8422P, NVR ND9525P and NVR ND9541P 2.4.0.204/3.3.0.104/4.2.0.101. It has been classified as problematic. Affected is an unknown function of the component HTML Form Handler. The manipulation leads to inclusion of sensitive information in source code. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-540 - Inclusion of Sensitive Information in Source Code
    • CWE-200 - Information Disclosure
    Assigner
    References
    Impacted products
    Vendor Product Version
    Vivotek NVR ND8422P Affected: 2.4.0.204
    Affected: 3.3.0.104
    Affected: 4.2.0.101
    Create a notification for this product.
    Vivotek NVR ND9525P Affected: 2.4.0.204
    Affected: 3.3.0.104
    Affected: 4.2.0.101
    Create a notification for this product.
    Vivotek NVR ND9541P Affected: 2.4.0.204
    Affected: 3.3.0.104
    Affected: 4.2.0.101
    Create a notification for this product.
    Credits
    Syrtain (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3403",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-08T15:46:08.310718Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-08T18:24:22.074Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://github.com/lfparizzi/CVE-VIVOTEK-ID/blob/main/README.md"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "HTML Form Handler"
              ],
              "product": "NVR ND8422P",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.4.0.204"
                },
                {
                  "status": "affected",
                  "version": "3.3.0.104"
                },
                {
                  "status": "affected",
                  "version": "4.2.0.101"
                }
              ]
            },
            {
              "modules": [
                "HTML Form Handler"
              ],
              "product": "NVR ND9525P",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.4.0.204"
                },
                {
                  "status": "affected",
                  "version": "3.3.0.104"
                },
                {
                  "status": "affected",
                  "version": "4.2.0.101"
                }
              ]
            },
            {
              "modules": [
                "HTML Form Handler"
              ],
              "product": "NVR ND9541P",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.4.0.204"
                },
                {
                  "status": "affected",
                  "version": "3.3.0.104"
                },
                {
                  "status": "affected",
                  "version": "4.2.0.101"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Syrtain (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Vivotek NVR ND8422P, NVR ND9525P and NVR ND9541P 2.4.0.204/3.3.0.104/4.2.0.101. It has been classified as problematic. Affected is an unknown function of the component HTML Form Handler. The manipulation leads to inclusion of sensitive information in source code. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Es wurde eine problematische Schwachstelle in Vivotek NVR ND8422P, NVR ND9525P and NVR ND9541P 2.4.0.204/3.3.0.104/4.2.0.101 ausgemacht. Dabei betrifft es einen unbekannter Codeteil der Komponente HTML Form Handler. Durch Manipulation mit unbekannten Daten kann eine inclusion of sensitive information in source code-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 3.3,
                "vectorString": "AV:N/AC:L/Au:M/C:P/I:N/A:N",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-540",
                  "description": "Inclusion of Sensitive Information in Source Code",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "Information Disclosure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-04-08T03:00:11.278Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-303648 | Vivotek NVR ND8422P/NVR ND9525P/NVR ND9541P HTML Form sensitive information in source",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.303648"
            },
            {
              "name": "VDB-303648 | CTI Indicators (IOB, IOC, TTP)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.303648"
            },
            {
              "name": "Submit #543589 | VIVOTEK NVR Core + 4.2.0.101 and below Cleartext Storage of Sensitive Information in GUI",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.543589"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/lfparizzi/CVE-VIVOTEK-ID/blob/main/README.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-04-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-04-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-04-07T12:27:05.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Vivotek NVR ND8422P/NVR ND9525P/NVR ND9541P HTML Form sensitive information in source"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-3403",
        "datePublished": "2025-04-08T03:00:11.278Z",
        "dateReserved": "2025-04-07T10:22:01.598Z",
        "dateUpdated": "2025-04-08T18:24:22.074Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7443 (GCVE-0-2024-7443)

    Vulnerability from nvd – Published: 2024-08-03 19:00 – Updated: 2024-08-05 18:43 Unsupported When Assigned
    VLAI
    Title
    Vivotek IB8367A upload_file.cgi getenv command injection
    Summary
    ** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in Vivotek IB8367A VVTK-0100b. Affected is the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-273528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273528 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273528 signaturepermissions-required
    https://vuldb.com/?submit.383844 third-party-advisory
    https://yjz233.notion.site/vivotek-IB8367A-has-co… broken-link
    Impacted products
    Vendor Product Version
    Vivotek IB8367A Affected: VVTK-0100b
    Create a notification for this product.
    vivotek ib8367a Affected: vvtk-0100b
        cpe:2.3:h:vivotek:ib8367a:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    jylsec (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:vivotek:ib8367a:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ib8367a",
                "vendor": "vivotek",
                "versions": [
                  {
                    "status": "affected",
                    "version": "vvtk-0100b"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7443",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-05T18:41:22.552464Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-05T18:43:32.506Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "IB8367A",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "VVTK-0100b"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jylsec (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in Vivotek IB8367A VVTK-0100b. Affected is the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-273528. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
            },
            {
              "lang": "de",
              "value": "Es wurde eine kritische Schwachstelle in Vivotek IB8367A VVTK-0100b entdeckt. Dabei betrifft es die Funktion getenv der Datei upload_file.cgi. Mit der Manipulation des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-03T19:00:09.314Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273528 | Vivotek IB8367A upload_file.cgi getenv command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273528"
            },
            {
              "name": "VDB-273528 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273528"
            },
            {
              "name": "Submit #383844 | vivotek IB8367A VVTK-0100b command injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.383844"
            },
            {
              "tags": [
                "broken-link"
              ],
              "url": "https://yjz233.notion.site/vivotek-IB8367A-has-command-injection-vulnerability-in-upload_file-cgi-899e5d529fb14b4189534b2b9830bfff?pvs=4"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-02T23:46:28.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Vivotek IB8367A upload_file.cgi getenv command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7443",
        "datePublished": "2024-08-03T19:00:09.314Z",
        "dateReserved": "2024-08-02T21:36:43.428Z",
        "dateUpdated": "2024-08-05T18:43:32.506Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7442 (GCVE-0-2024-7442)

    Vulnerability from nvd – Published: 2024-08-03 18:00 – Updated: 2024-08-05 15:04 Unsupported When Assigned
    VLAI
    Title
    Vivotek SD9364 upload_file.cgi getenv command injection
    Summary
    ** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical. This issue affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273527 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273527 signaturepermissions-required
    https://vuldb.com/?submit.383843 third-party-advisory
    https://yjz233.notion.site/vivotek-SD9364-has-com… broken-link
    Impacted products
    Vendor Product Version
    Vivotek SD9364 Affected: VVTK-0103f
    Create a notification for this product.
    Credits
    jylsec (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7442",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-05T15:04:20.396388Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-05T15:04:43.133Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SD9364",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "VVTK-0103f"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jylsec (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical. This issue affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Vivotek SD9364 VVTK-0103f ausgemacht. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion getenv der Datei upload_file.cgi. Dank Manipulation des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-03T18:00:09.890Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273527 | Vivotek SD9364 upload_file.cgi getenv command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273527"
            },
            {
              "name": "VDB-273527 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273527"
            },
            {
              "name": "Submit #383843 | vivotek SD9364 VVTK-0103f command injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.383843"
            },
            {
              "tags": [
                "broken-link"
              ],
              "url": "https://yjz233.notion.site/vivotek-SD9364-has-command-injection-vulnerability-in-upload_file-cgi-5cef6da27b25479497dda0b73670f565?pvs=4"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-02T23:46:16.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Vivotek SD9364 upload_file.cgi getenv command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7442",
        "datePublished": "2024-08-03T18:00:09.890Z",
        "dateReserved": "2024-08-02T21:36:40.547Z",
        "dateUpdated": "2024-08-05T15:04:43.133Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7441 (GCVE-0-2024-7441)

    Vulnerability from nvd – Published: 2024-08-03 17:31 – Updated: 2024-08-07 16:24 Unsupported When Assigned
    VLAI
    Title
    Vivotek SD9364 httpd read stack-based overflow
    Summary
    ** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273526 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273526 signaturepermissions-required
    https://vuldb.com/?submit.383842 third-party-advisory
    https://yjz233.notion.site/vivotek-SD9364-has-sta… broken-linkexploit
    Impacted products
    Vendor Product Version
    Vivotek SD9364 Affected: VVTK-0103f
    Create a notification for this product.
    vivotek sd9364_firmware Affected: vvtk-0103f
        cpe:2.3:o:vivotek:sd9364_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    jylsec (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:vivotek:sd9364_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sd9364_firmware",
                "vendor": "vivotek",
                "versions": [
                  {
                    "status": "affected",
                    "version": "vvtk-0103f"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7441",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-07T16:17:09.130706Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-07T16:24:42.771Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "httpd"
              ],
              "product": "SD9364",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "VVTK-0103f"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jylsec (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
            },
            {
              "lang": "de",
              "value": "In Vivotek SD9364 VVTK-0103f wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Das betrifft die Funktion read der Komponente httpd. Dank der Manipulation des Arguments Content-Length mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-03T17:31:04.573Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273526 | Vivotek SD9364 httpd read stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273526"
            },
            {
              "name": "VDB-273526 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273526"
            },
            {
              "name": "Submit #383842 | vivotek SD9364 VVTK-0103f buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.383842"
            },
            {
              "tags": [
                "broken-link",
                "exploit"
              ],
              "url": "https://yjz233.notion.site/vivotek-SD9364-has-stack-buffer-overflow-vulnerability-in-httpd-c9dabd0511d04093865d1d75110429d1?pvs=4"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-02T23:46:19.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Vivotek SD9364 httpd read stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7441",
        "datePublished": "2024-08-03T17:31:04.573Z",
        "dateReserved": "2024-08-02T21:36:37.042Z",
        "dateUpdated": "2024-08-07T16:24:42.771Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7440 (GCVE-0-2024-7440)

    Vulnerability from nvd – Published: 2024-08-03 16:31 – Updated: 2024-08-07 20:36 Unsupported When Assigned
    VLAI
    Title
    Vivotek CC8160 upload_file.cgi getenv command injection
    Summary
    ** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d. It has been classified as critical. This affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to initiate the attack remotely. The identifier VDB-273525 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273525 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273525 signaturepermissions-required
    https://vuldb.com/?submit.383839 third-party-advisory
    https://yjz233.notion.site/0213043a8c7e498a9e73a0… broken-link
    Impacted products
    Vendor Product Version
    Vivotek CC8160 Affected: VVTK-0100d
    Create a notification for this product.
    Credits
    jylsec (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7440",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-07T20:35:43.991104Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-07T20:36:03.492Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CC8160",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "VVTK-0100d"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jylsec (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d. It has been classified as critical. This affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to initiate the attack remotely. The identifier VDB-273525 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
            },
            {
              "lang": "de",
              "value": "Es wurde eine Schwachstelle in Vivotek CC8160 VVTK-0100d ausgemacht. Sie wurde als kritisch eingestuft. Es betrifft die Funktion getenv der Datei upload_file.cgi. Durch Beeinflussen des Arguments QUERY_STRING mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-03T16:31:04.256Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273525 | Vivotek CC8160 upload_file.cgi getenv command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273525"
            },
            {
              "name": "VDB-273525 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273525"
            },
            {
              "name": "Submit #383839 | vivotek CC8160 VVTK-0100d command injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.383839"
            },
            {
              "tags": [
                "broken-link"
              ],
              "url": "https://yjz233.notion.site/0213043a8c7e498a9e73a0b6f0fa9f29?pvs=4"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-02T23:46:14.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Vivotek CC8160 upload_file.cgi getenv command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7440",
        "datePublished": "2024-08-03T16:31:04.256Z",
        "dateReserved": "2024-08-02T21:36:34.385Z",
        "dateUpdated": "2024-08-07T20:36:03.492Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7439 (GCVE-0-2024-7439)

    Vulnerability from nvd – Published: 2024-08-03 16:00 – Updated: 2024-08-05 15:09 Unsupported When Assigned
    VLAI
    Title
    Vivotek CC8160 httpd read stack-based overflow
    Summary
    ** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d and classified as critical. Affected by this issue is the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-273524. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.273524 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.273524 signaturepermissions-required
    https://vuldb.com/?submit.383830 third-party-advisory
    https://yjz233.notion.site/vivotek-CC8160-has-sta… broken-linkexploit
    Impacted products
    Vendor Product Version
    Vivotek CC8160 Affected: VVTK-0100d
    Create a notification for this product.
    vivotek cc8160 Affected: VVTK-0100d
        cpe:2.3:h:vivotek:cc8160:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    jylsec (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:vivotek:cc8160:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cc8160",
                "vendor": "vivotek",
                "versions": [
                  {
                    "status": "affected",
                    "version": "VVTK-0100d"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7439",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-05T15:07:46.604884Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-05T15:09:25.672Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "httpd"
              ],
              "product": "CC8160",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "VVTK-0100d"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jylsec (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d and classified as critical. Affected by this issue is the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-273524. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Vivotek CC8160 VVTK-0100d gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion read der Komponente httpd. Durch das Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-03T16:00:07.798Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273524 | Vivotek CC8160 httpd read stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273524"
            },
            {
              "name": "VDB-273524 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273524"
            },
            {
              "name": "Submit #383830 | VIVOTEK CC8160 VVTK-0100d buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.383830"
            },
            {
              "tags": [
                "broken-link",
                "exploit"
              ],
              "url": "https://yjz233.notion.site/vivotek-CC8160-has-stack-buffer-overflow-vulnerability-in-httpd-8409f967d3064493b649720f36d59081?pvs=4"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-02T23:46:03.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Vivotek CC8160 httpd read stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7439",
        "datePublished": "2024-08-03T16:00:07.798Z",
        "dateReserved": "2024-08-02T21:36:32.099Z",
        "dateUpdated": "2024-08-05T15:09:25.672Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    VAR-201907-1136

    Vulnerability from variot - Updated: 2024-05-17 23:09

    Vivotek FD8136 devices allow Remote Command Injection, related to BusyBox and wget. NOTE: the vendor sent a clarification on 2019-09-17 explaining that, although this CVE was first populated in July 2019, it is a historical vulnerability that does not apply to any current or recent Vivotek hardware or firmware. Vivotek FD8136 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China's Taiwan Vivotek. There is a command injection vulnerability in VivotekFD8136. The vulnerability stems from the fact that external input data constructs executable commands, and the network system or product does not properly filter the special elements. An attacker could exploit the vulnerability to execute an illegal command

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1136",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "fd8136",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "vivotek",
            "version": "0301a"
          },
          {
            "model": "network camera fd8136",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "fd8136",
            "scope": null,
            "trust": 0.6,
            "vendor": "vivotek",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:vivotek:fd8136_firmware:0301a:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:vivotek:fd8136:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "cve": "CVE-2018-14494",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 10.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2018-14494",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-22783",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-124659",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-14494",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-14494",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-22783",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201907-552",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-124659",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124659"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vivotek FD8136 devices allow Remote Command Injection, related to BusyBox and wget. NOTE: the vendor sent a clarification on 2019-09-17 explaining that, although this CVE was first populated in July 2019, it is a historical vulnerability that does not apply to any current or recent Vivotek hardware or firmware. Vivotek FD8136 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China\u0027s Taiwan Vivotek. There is a command injection vulnerability in VivotekFD8136. The vulnerability stems from the fact that external input data constructs executable commands, and the network system or product does not properly filter the special elements. An attacker could exploit the vulnerability to execute an illegal command",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124659"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-14494",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-552",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-124659",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124659"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "id": "VAR-201907-1136",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124659"
          }
        ],
        "trust": 1.45
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS",
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          }
        ]
      },
      "last_update_date": "2024-05-17T23:09:49.734000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "FD8136",
            "trust": 0.8,
            "url": "https://www.vivotek.com/fd8136"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-77",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124659"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://www.vdalabs.com/2018/07/23/professional-iot-hacking-series-target-selection-firmware-analysis/"
          },
          {
            "trust": 2.3,
            "url": "https://www.vdalabs.com/2018/08/06/professional-iot-hacking-series-hunting-remote-command-injection/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14494"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14494"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124659"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124659"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "date": "2019-07-10T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124659"
          },
          {
            "date": "2019-07-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "date": "2019-07-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          },
          {
            "date": "2019-07-10T13:15:10.590000",
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-16T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-22783"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124659"
          },
          {
            "date": "2019-07-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          },
          {
            "date": "2020-10-28T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          },
          {
            "date": "2024-05-17T01:23:56.227000",
            "db": "NVD",
            "id": "CVE-2018-14494"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vivotek FD8136 Command injection vulnerability in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015834"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-552"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201907-1138

    Vulnerability from variot - Updated: 2024-05-17 23:09

    Vivotek FD8136 devices allow remote memory corruption and remote code execution because of a stack-based buffer overflow, related to sprintf, vlocal_buff_4326, and set_getparam.cgi. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance. Vivotek FD8136 The device contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China's Taiwan Vivotek. A buffer overflow vulnerability exists in VivotekFD8136 that could allow an attacker to cause a buffer overflow or heap overflow. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1138",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "fd8136",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "vivotek",
            "version": "0301a"
          },
          {
            "model": "network camera fd8136",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "fd8136",
            "scope": null,
            "trust": 0.6,
            "vendor": "vivotek",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:vivotek:fd8136_firmware:0301a:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:vivotek:fd8136:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "cve": "CVE-2018-14496",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 7.5,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2018-14496",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-22271",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-124661",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-14496",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-14496",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-22271",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201907-555",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-124661",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124661"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vivotek FD8136 devices allow remote memory corruption and remote code execution because of a stack-based buffer overflow, related to sprintf, vlocal_buff_4326, and set_getparam.cgi. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it\u0027s performance. Vivotek FD8136 The device contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China\u0027s Taiwan Vivotek. A buffer overflow vulnerability exists in VivotekFD8136 that could allow an attacker to cause a buffer overflow or heap overflow. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124661"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-14496",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-555",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-124661",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124661"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "id": "VAR-201907-1138",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124661"
          }
        ],
        "trust": 1.45
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          }
        ]
      },
      "last_update_date": "2024-05-17T23:09:26.724000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "FD8136",
            "trust": 0.8,
            "url": "https://www.vivotek.com/fd8136"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-119",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124661"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.1,
            "url": "https://www.vdalabs.com/2018/07/23/professional-iot-hacking-series-target-selection-firmware-analysis/"
          },
          {
            "trust": 2.3,
            "url": "https://www.vdalabs.com/2018/11/29/professional-iot-hacking-series-hunting-remote-memory-corruption/"
          },
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14496"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14496"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124661"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124661"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "date": "2019-07-10T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124661"
          },
          {
            "date": "2019-07-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "date": "2019-07-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          },
          {
            "date": "2019-07-10T14:15:10.730000",
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-22271"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124661"
          },
          {
            "date": "2019-07-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          },
          {
            "date": "2020-08-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          },
          {
            "date": "2024-05-17T01:23:56.470000",
            "db": "NVD",
            "id": "CVE-2018-14496"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vivotek FD8136 Device buffer error vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015836"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-555"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201907-1137

    Vulnerability from variot - Updated: 2024-05-17 22:51

    Vivotek FD8136 devices allow Remote Command Injection, aka "another command injection vulnerability in our target device," a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance. This vulnerability CVE-2018-14494 Is a different vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China's Taiwan Vivotek. This vulnerability is caused by external input data constructing executable commands. The network system or product does not properly filter the special elements. Attackers can use this vulnerability to execute illegal commands

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1137",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "fd8136",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "vivotek",
            "version": "0301a"
          },
          {
            "model": "network camera fd8136",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "fd8136",
            "scope": null,
            "trust": 0.6,
            "vendor": "vivotek",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:vivotek:fd8136_firmware:0301a:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:vivotek:fd8136:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "cve": "CVE-2018-14495",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 10.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2018-14495",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.9,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-22270",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-124660",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-14495",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-14495",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-22270",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201907-553",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-124660",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2018-14495",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14495"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vivotek FD8136 devices allow Remote Command Injection, aka \"another command injection vulnerability in our target device,\" a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it\u0027s performance. This vulnerability CVE-2018-14494 Is a different vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China\u0027s Taiwan Vivotek. This vulnerability is caused by external input data constructing executable commands. The network system or product does not properly filter the special elements. Attackers can use this vulnerability to execute illegal commands",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14495"
          }
        ],
        "trust": 2.34
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-14495",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-553",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-124660",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14495",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14495"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "id": "VAR-201907-1137",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124660"
          }
        ],
        "trust": 1.45
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          }
        ]
      },
      "last_update_date": "2024-05-17T22:51:07.153000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "FD8136",
            "trust": 0.8,
            "url": "https://www.vivotek.com/fd8136"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-77",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.2,
            "url": "https://www.vdalabs.com/2018/07/23/professional-iot-hacking-series-target-selection-firmware-analysis/"
          },
          {
            "trust": 2.4,
            "url": "https://www.vdalabs.com/2018/08/06/professional-iot-hacking-series-hunting-remote-command-injection/"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14495"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14495"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/78.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14495"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14495"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "date": "2019-07-10T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "date": "2019-07-10T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-14495"
          },
          {
            "date": "2019-07-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "date": "2019-07-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          },
          {
            "date": "2019-07-10T14:15:10.637000",
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-07-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-22270"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124660"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-14495"
          },
          {
            "date": "2019-07-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          },
          {
            "date": "2020-10-28T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          },
          {
            "date": "2024-05-17T01:23:56.370000",
            "db": "NVD",
            "id": "CVE-2018-14495"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vivotek FD8136 Command injection vulnerability in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-015835"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201907-553"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201809-0170

    Vulnerability from variot - Updated: 2024-02-06 23:05

    VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi. VIVOTEK FD8177 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VIVOTEKFD8177 is a network camera product from Vivotek. A command injection vulnerability exists in versions prior to VIVOTEKFD8177XXXXXX-VVTK-xx06a

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0170",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "camera",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "camera",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "fd8177 \u003cxxxxxx-vvtk-xx06a",
            "scope": null,
            "trust": 0.6,
            "vendor": "vivotek",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:vivotek:camera:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "cve": "CVE-2018-14771",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2018-14771",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.9,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2019-06202",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "VHN-124964",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-14771",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-14771",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-06202",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201809-207",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-124964",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2018-14771",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14771"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi. VIVOTEK FD8177 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VIVOTEKFD8177 is a network camera product from Vivotek. A command injection vulnerability exists in versions prior to VIVOTEKFD8177XXXXXX-VVTK-xx06a",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14771"
          }
        ],
        "trust": 2.34
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-14771",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-124964",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14771",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14771"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "id": "VAR-201809-0170",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124964"
          }
        ],
        "trust": 1.6391892
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          }
        ]
      },
      "last_update_date": "2024-02-06T23:05:15.846000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "VVTK-SA-2018-003",
            "trust": 0.8,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
          },
          {
            "title": "Cybersecurity",
            "trust": 0.8,
            "url": "https://www.vivotek.com/website/support/cybersecurity/"
          },
          {
            "title": "VIVOTEKFD8177 command to inject vulnerability patch",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/155263"
          },
          {
            "title": "VIVOTEK FD8177 Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=84543"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-77",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
          },
          {
            "trust": 1.8,
            "url": "https://www.vivotek.com/website/support/cybersecurity/"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14771"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14771"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14771"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14771"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-03-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "date": "2018-09-05T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "date": "2018-09-05T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-14771"
          },
          {
            "date": "2018-12-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "date": "2018-09-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          },
          {
            "date": "2018-09-05T21:29:00.907000",
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-03-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-14771"
          },
          {
            "date": "2018-12-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "date": "2020-10-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          },
          {
            "date": "2020-08-24T17:37:01.140000",
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK FD8177 Command Injection Vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          }
        ],
        "trust": 1.2
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201909-1017

    Vulnerability from variot - Updated: 2023-12-18 14:00

    VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header. VIVOTEK IP Camera The device firmware contains a classic buffer overflow vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201909-1017",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "camera",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "camera",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "vivotek",
            "version": "0x20x"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:vivotek:camera:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          }
        ]
      },
      "cve": "CVE-2019-14457",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 7.5,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2019-14457",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-146405",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-14457",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-14457",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201909-456",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-146405",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-146405"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header. VIVOTEK IP Camera The device firmware contains a classic buffer overflow vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "VULHUB",
            "id": "VHN-146405"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-14457",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-146405",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-146405"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          }
        ]
      },
      "id": "VAR-201909-1017",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-146405"
          }
        ],
        "trust": 0.9783784
      },
      "last_update_date": "2023-12-18T14:00:48.490000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "VVTK\u2212SA-2019-002",
            "trust": 0.8,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
          },
          {
            "title": "VIVOTEK IP Camera Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=98049"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-120",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-146405"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-14457"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-14457"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-146405"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-146405"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-09-10T00:00:00",
            "db": "VULHUB",
            "id": "VHN-146405"
          },
          {
            "date": "2019-09-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "date": "2019-09-10T18:15:12.900000",
            "db": "NVD",
            "id": "CVE-2019-14457"
          },
          {
            "date": "2019-09-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-09-16T00:00:00",
            "db": "VULHUB",
            "id": "VHN-146405"
          },
          {
            "date": "2019-09-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "date": "2021-07-21T11:39:23.747000",
            "db": "NVD",
            "id": "CVE-2019-14457"
          },
          {
            "date": "2021-07-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK IP Camera Classic buffer overflow vulnerability in device firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201706-1010

    Vulnerability from variot - Updated: 2023-12-18 13:57

    '/cgi-bin/admin/downloadMedias.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable, which allows remote attackers to read any file on the camera's Linux filesystem via a crafted HTTP request containing ".." sequences. This vulnerability is already verified on VIVOTEK Network Camera IB8369/FD8164/FD816BA; most others have similar firmware that may be affected. VIVOTEKNetworkCameras IB8369, FD8164 and FD816BA are all network camera products of China VIVOTEK

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201706-1010",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "network camera fd816ba",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "vivotek",
            "version": "fd816ba-vvtk-010101."
          },
          {
            "model": "network camera fd8164",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "vivotek",
            "version": "fd8164-_vvtk-0200b"
          },
          {
            "model": "network camera ib8369",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "vivotek",
            "version": "ib8369-vvtk-0102a"
          },
          {
            "model": "network camera fd8164",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "network camera fd816ba",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "network camera ib8369",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "ib8369",
            "scope": null,
            "trust": 0.6,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "fd8164",
            "scope": null,
            "trust": 0.6,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "fd816ba",
            "scope": null,
            "trust": 0.6,
            "vendor": "vivotek",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-12592"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-005191"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9829"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-1060"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:vivotek:network_camera_ib8369_firmware:ib8369-vvtk-0102a:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:vivotek:network_camera_ib8369:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:vivotek:network_camera_fd8164_firmware:fd8164-_vvtk-0200b:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:vivotek:network_camera_fd8164:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:vivotek:network_camera_fd816ba_firmware:fd816ba-vvtk-010101.:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:vivotek:network_camera_fd816ba:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-9829"
          }
        ]
      },
      "cve": "CVE-2017-9829",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 5.0,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2017-9829",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2017-12592",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-118032",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2017-9829",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2017-9829",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-12592",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201706-1060",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-118032",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-12592"
          },
          {
            "db": "VULHUB",
            "id": "VHN-118032"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-005191"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9829"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-1060"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "\u0027/cgi-bin/admin/downloadMedias.cgi\u0027 of the web service in most of the VIVOTEK Network Cameras is vulnerable, which allows remote attackers to read any file on the camera\u0027s Linux filesystem via a crafted HTTP request containing \"..\" sequences. This vulnerability is already verified on VIVOTEK Network Camera IB8369/FD8164/FD816BA; most others have similar firmware that may be affected. VIVOTEKNetworkCameras IB8369, FD8164 and FD816BA are all network camera products of China VIVOTEK",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-9829"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-005191"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-12592"
          },
          {
            "db": "VULHUB",
            "id": "VHN-118032"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-9829",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-005191",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-1060",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-12592",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-118032",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-12592"
          },
          {
            "db": "VULHUB",
            "id": "VHN-118032"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-005191"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9829"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-1060"
          }
        ]
      },
      "id": "VAR-201706-1010",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-12592"
          },
          {
            "db": "VULHUB",
            "id": "VHN-118032"
          }
        ],
        "trust": 1.60625
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-12592"
          }
        ]
      },
      "last_update_date": "2023-12-18T13:57:18.539000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "VIVOTEK Network Cameras",
            "trust": 0.8,
            "url": "http://www.vivotek.com/network-cameras/#type-filter:path=default|resolution-filter:path=default|snv-filter:path=default|wdr-filter:path=default|lens-filter:path=default|ir-filter:path=default|environment-filter:path=default|views:view=jplist-grid-view"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-005191"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-22",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-118032"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-005191"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9829"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.1,
            "url": "https://blog.cal1.cn/post/an%20easy%20way%20to%20pwn%20most%20of%20the%20vivotek%20network%20cameras"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9829"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9829"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-12592"
          },
          {
            "db": "VULHUB",
            "id": "VHN-118032"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-005191"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9829"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-1060"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-12592"
          },
          {
            "db": "VULHUB",
            "id": "VHN-118032"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-005191"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9829"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-1060"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-07-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-12592"
          },
          {
            "date": "2017-06-23T00:00:00",
            "db": "VULHUB",
            "id": "VHN-118032"
          },
          {
            "date": "2017-07-20T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-005191"
          },
          {
            "date": "2017-06-23T22:29:00.210000",
            "db": "NVD",
            "id": "CVE-2017-9829"
          },
          {
            "date": "2017-06-28T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-1060"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-07-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-12592"
          },
          {
            "date": "2017-07-05T00:00:00",
            "db": "VULHUB",
            "id": "VHN-118032"
          },
          {
            "date": "2017-07-20T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-005191"
          },
          {
            "date": "2017-07-05T17:49:02.913000",
            "db": "NVD",
            "id": "CVE-2017-9829"
          },
          {
            "date": "2017-06-28T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-1060"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-1060"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  VIVOTEK Network Camera Product  Web Service of  /cgi-bin/admin/downloadMedias.cgi Vulnerable to reading arbitrary files",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-005191"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "path traversal",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-1060"
          }
        ],
        "trust": 0.6
      }
    }