CVE-2026-76105 (GCVE-0-2026-76105)
Vulnerability from nvd – Published: 2026-10-06 15:10 – Updated: 2026-10-06 19:30- CWE-330 - Use of Insufficiently Random Values
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-76105",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T19:25:50.986173Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:30:04.529Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0 contain(s) an Use of Insufficiently Random Values vulnerability. An unauthenticated attacker with local access could potentially exploit this vulnerability, leading to Information tampering."
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0 contain(s) an Use of Insufficiently Random Values vulnerability. An unauthenticated attacker with local access could potentially exploit this vulnerability, leading to Information tampering."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-330",
"description": "CWE-330: Use of Insufficiently Random Values",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T15:10:01.583Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-76105",
"datePublished": "2026-10-06T15:10:01.583Z",
"dateReserved": "2026-08-18T23:05:02.337Z",
"dateUpdated": "2026-10-06T19:30:04.529Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-67273 (GCVE-0-2026-67273)
Vulnerability from nvd – Published: 2026-10-06 15:02 – Updated: 2026-10-06 15:02- CWE-1336 - Improper Neutralization of Special Elements Used in a Template Engine
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank rudra_16 for reporting this issue."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1336",
"description": "CWE-1336: Improper Neutralization of Special Elements Used in a Template Engine",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T15:02:34.658Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-67273",
"datePublished": "2026-10-06T15:02:34.658Z",
"dateReserved": "2026-07-29T11:04:32.679Z",
"dateUpdated": "2026-10-06T15:02:34.658Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-63691 (GCVE-0-2026-63691)
Vulnerability from nvd – Published: 2026-10-06 15:25 – Updated: 2026-10-06 15:25- CWE-862 - Missing Authorization
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank chwrld for reporting these issues."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) a Missing Authorization vulnerability in the Dell CSI Driver for PowerMax - csireverseproxy . An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) a Missing Authorization vulnerability in the Dell CSI Driver for PowerMax - csireverseproxy . An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862: Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T15:25:41.217Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-63691",
"datePublished": "2026-10-06T15:25:41.217Z",
"dateReserved": "2026-07-17T17:05:09.170Z",
"dateUpdated": "2026-10-06T15:25:41.217Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-63690 (GCVE-0-2026-63690)
Vulnerability from nvd – Published: 2026-10-06 15:29 – Updated: 2026-10-06 17:19- CWE-306 - Missing Authentication for Critical Function
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-63690",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T17:19:51.218446Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T17:19:59.815Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank chwrld for reporting these issues."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) a Missing Authentication for Critical Function vulnerability in the csi-powerflex; csi-powermax; csi-powerstore. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) a Missing Authentication for Critical Function vulnerability in the csi-powerflex; csi-powermax; csi-powerstore. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T15:29:48.237Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-63690",
"datePublished": "2026-10-06T15:29:48.237Z",
"dateReserved": "2026-07-17T17:05:09.170Z",
"dateUpdated": "2026-10-06T17:19:59.815Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-63689 (GCVE-0-2026-63689)
Vulnerability from nvd – Published: 2026-10-06 15:21 – Updated: 2026-10-06 16:27- CWE-532 - Insertion of Sensitive Information into Log File
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-63689",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T16:27:15.348394Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T16:27:39.369Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank chwrld for reporting these issues."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T15:21:23.703Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-63689",
"datePublished": "2026-10-06T15:21:23.703Z",
"dateReserved": "2026-07-17T17:05:09.170Z",
"dateUpdated": "2026-10-06T16:27:39.369Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-61411 (GCVE-0-2026-61411)
Vulnerability from nvd – Published: 2026-10-06 15:14 – Updated: 2026-10-06 17:19- CWE-532 - Insertion of Sensitive Information into Log File
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-61411",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T17:19:32.014393Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T17:19:41.233Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank chwrld for reporting these issues."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T15:14:01.271Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-61411",
"datePublished": "2026-10-06T15:14:01.271Z",
"dateReserved": "2026-07-09T11:05:01.705Z",
"dateUpdated": "2026-10-06T17:19:41.233Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-63692 (GCVE-0-2026-63692)
Vulnerability from nvd – Published: 2026-10-06 14:38 – Updated: 2026-10-06 14:38- CWE-306 - Missing Authentication for Critical Function
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank chwrld for reporting these issues."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.\u0026nbsp;"
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T14:38:07.064Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-63692",
"datePublished": "2026-10-06T14:38:07.064Z",
"dateReserved": "2026-07-17T17:05:09.170Z",
"dateUpdated": "2026-10-06T14:38:07.064Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-61421 (GCVE-0-2026-61421)
Vulnerability from nvd – Published: 2026-10-06 14:57 – Updated: 2026-10-06 15:25- CWE-798 - Use of Hard-coded Credentials
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-61421",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T15:21:09.908355Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T15:25:08.047Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank heyysaiii for reporting this issue."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Use of Hard-coded Credentials vulnerability in the CSM Authorization. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.\u0026nbsp;"
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Use of Hard-coded Credentials vulnerability in the CSM Authorization. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T14:57:50.795Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-61421",
"datePublished": "2026-10-06T14:57:50.795Z",
"dateReserved": "2026-07-09T11:05:01.707Z",
"dateUpdated": "2026-10-06T15:25:08.047Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-54472 (GCVE-0-2026-54472)
Vulnerability from nvd – Published: 2026-10-06 14:51 – Updated: 2026-10-06 19:30- CWE-798 - Use of Hard-coded Credentials
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-54472",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T19:28:12.439501Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:30:17.052Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank lolsaiii for reporting this issue."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Use of Hard-coded Credentials vulnerability in the csm-docs. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.9.8"
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Use of Hard-coded Credentials vulnerability in the csm-docs. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.9.8"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T14:51:00.817Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-54472",
"datePublished": "2026-10-06T14:51:00.817Z",
"dateReserved": "2026-06-15T16:28:29.012Z",
"dateUpdated": "2026-10-06T19:30:17.052Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-40711 (GCVE-0-2026-40711)
Vulnerability from nvd – Published: 2026-06-26 12:31 – Updated: 2026-06-26 12:47- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-za/00047830… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 2.15.2 or later
(semver)
Affected: 0 , < 2.17.0 or later (semver) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40711",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-26T12:47:21.617512Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-26T12:47:26.963Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.15.2 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "2.17.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-06-18T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Dell Container Storage Modules, version(s) csi-powerstore v2.16.0, csi-unity v2.16.0, csi-powerflex v2.16.0, csi-powermax v2.16.0, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution."
}
],
"value": "Dell Dell Container Storage Modules, version(s) csi-powerstore v2.16.0, csi-unity v2.16.0, csi-powerflex v2.16.0, csi-powermax v2.16.0, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-26T12:31:00.184Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-za/000478300/dsa-2026-259-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=2e06327ba9266050201f2467a8f461dd"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-40711",
"datePublished": "2026-06-26T12:31:00.184Z",
"dateReserved": "2026-04-15T05:04:31.837Z",
"dateUpdated": "2026-06-26T12:47:26.963Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-63690 (GCVE-0-2026-63690)
Vulnerability from cvelistv5 – Published: 2026-10-06 15:29 – Updated: 2026-10-06 17:19- CWE-306 - Missing Authentication for Critical Function
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-63690",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T17:19:51.218446Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T17:19:59.815Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank chwrld for reporting these issues."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) a Missing Authentication for Critical Function vulnerability in the csi-powerflex; csi-powermax; csi-powerstore. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) a Missing Authentication for Critical Function vulnerability in the csi-powerflex; csi-powermax; csi-powerstore. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T15:29:48.237Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-63690",
"datePublished": "2026-10-06T15:29:48.237Z",
"dateReserved": "2026-07-17T17:05:09.170Z",
"dateUpdated": "2026-10-06T17:19:59.815Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-63691 (GCVE-0-2026-63691)
Vulnerability from cvelistv5 – Published: 2026-10-06 15:25 – Updated: 2026-10-06 15:25- CWE-862 - Missing Authorization
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank chwrld for reporting these issues."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) a Missing Authorization vulnerability in the Dell CSI Driver for PowerMax - csireverseproxy . An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) a Missing Authorization vulnerability in the Dell CSI Driver for PowerMax - csireverseproxy . An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862: Missing Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T15:25:41.217Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-63691",
"datePublished": "2026-10-06T15:25:41.217Z",
"dateReserved": "2026-07-17T17:05:09.170Z",
"dateUpdated": "2026-10-06T15:25:41.217Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-63689 (GCVE-0-2026-63689)
Vulnerability from cvelistv5 – Published: 2026-10-06 15:21 – Updated: 2026-10-06 16:27- CWE-532 - Insertion of Sensitive Information into Log File
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-63689",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T16:27:15.348394Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T16:27:39.369Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank chwrld for reporting these issues."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T15:21:23.703Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-63689",
"datePublished": "2026-10-06T15:21:23.703Z",
"dateReserved": "2026-07-17T17:05:09.170Z",
"dateUpdated": "2026-10-06T16:27:39.369Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-61411 (GCVE-0-2026-61411)
Vulnerability from cvelistv5 – Published: 2026-10-06 15:14 – Updated: 2026-10-06 17:19- CWE-532 - Insertion of Sensitive Information into Log File
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-61411",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T17:19:32.014393Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T17:19:41.233Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank chwrld for reporting these issues."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T15:14:01.271Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-61411",
"datePublished": "2026-10-06T15:14:01.271Z",
"dateReserved": "2026-07-09T11:05:01.705Z",
"dateUpdated": "2026-10-06T17:19:41.233Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-76105 (GCVE-0-2026-76105)
Vulnerability from cvelistv5 – Published: 2026-10-06 15:10 – Updated: 2026-10-06 19:30- CWE-330 - Use of Insufficiently Random Values
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-76105",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T19:25:50.986173Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:30:04.529Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0 contain(s) an Use of Insufficiently Random Values vulnerability. An unauthenticated attacker with local access could potentially exploit this vulnerability, leading to Information tampering."
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0 contain(s) an Use of Insufficiently Random Values vulnerability. An unauthenticated attacker with local access could potentially exploit this vulnerability, leading to Information tampering."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-330",
"description": "CWE-330: Use of Insufficiently Random Values",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T15:10:01.583Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-76105",
"datePublished": "2026-10-06T15:10:01.583Z",
"dateReserved": "2026-08-18T23:05:02.337Z",
"dateUpdated": "2026-10-06T19:30:04.529Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-67273 (GCVE-0-2026-67273)
Vulnerability from cvelistv5 – Published: 2026-10-06 15:02 – Updated: 2026-10-06 15:02- CWE-1336 - Improper Neutralization of Special Elements Used in a Template Engine
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank rudra_16 for reporting this issue."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1336",
"description": "CWE-1336: Improper Neutralization of Special Elements Used in a Template Engine",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T15:02:34.658Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-67273",
"datePublished": "2026-10-06T15:02:34.658Z",
"dateReserved": "2026-07-29T11:04:32.679Z",
"dateUpdated": "2026-10-06T15:02:34.658Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-61421 (GCVE-0-2026-61421)
Vulnerability from cvelistv5 – Published: 2026-10-06 14:57 – Updated: 2026-10-06 15:25- CWE-798 - Use of Hard-coded Credentials
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-61421",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T15:21:09.908355Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T15:25:08.047Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank heyysaiii for reporting this issue."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Use of Hard-coded Credentials vulnerability in the CSM Authorization. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.\u0026nbsp;"
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Use of Hard-coded Credentials vulnerability in the CSM Authorization. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T14:57:50.795Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-61421",
"datePublished": "2026-10-06T14:57:50.795Z",
"dateReserved": "2026-07-09T11:05:01.707Z",
"dateUpdated": "2026-10-06T15:25:08.047Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-54472 (GCVE-0-2026-54472)
Vulnerability from cvelistv5 – Published: 2026-10-06 14:51 – Updated: 2026-10-06 19:30- CWE-798 - Use of Hard-coded Credentials
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-54472",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T19:28:12.439501Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:30:17.052Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank lolsaiii for reporting this issue."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Use of Hard-coded Credentials vulnerability in the csm-docs. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.9.8"
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Use of Hard-coded Credentials vulnerability in the csm-docs. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.9.8"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T14:51:00.817Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-54472",
"datePublished": "2026-10-06T14:51:00.817Z",
"dateReserved": "2026-06-15T16:28:29.012Z",
"dateUpdated": "2026-10-06T19:30:17.052Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-63692 (GCVE-0-2026-63692)
Vulnerability from cvelistv5 – Published: 2026-10-06 14:38 – Updated: 2026-10-06 14:38- CWE-306 - Missing Authentication for Critical Function
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00051577… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 1.18.0 or later
(semver)
|
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.18.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Dell would like to thank chwrld for reporting these issues."
}
],
"datePublic": "2026-10-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.\u0026nbsp;"
}
],
"value": "Dell Container Storage Modules, versions prior to 1.18.0, contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T14:38:07.064Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000515771/dsa-2026-448-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-63692",
"datePublished": "2026-10-06T14:38:07.064Z",
"dateReserved": "2026-07-17T17:05:09.170Z",
"dateUpdated": "2026-10-06T14:38:07.064Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-40711 (GCVE-0-2026-40711)
Vulnerability from cvelistv5 – Published: 2026-06-26 12:31 – Updated: 2026-06-26 12:47- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-za/00047830… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Container Storage Modules |
Affected:
0 , < 2.15.2 or later
(semver)
Affected: 0 , < 2.17.0 or later (semver) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40711",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-26T12:47:21.617512Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-26T12:47:26.963Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Container Storage Modules",
"vendor": "Dell",
"versions": [
{
"lessThan": "2.15.2 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "2.17.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-06-18T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Dell Container Storage Modules, version(s) csi-powerstore v2.16.0, csi-unity v2.16.0, csi-powerflex v2.16.0, csi-powermax v2.16.0, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution."
}
],
"value": "Dell Dell Container Storage Modules, version(s) csi-powerstore v2.16.0, csi-unity v2.16.0, csi-powerflex v2.16.0, csi-powermax v2.16.0, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-26T12:31:00.184Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-za/000478300/dsa-2026-259-security-update-for-dell-container-storage-modules-multiple-vulnerabilities?msockid=2e06327ba9266050201f2467a8f461dd"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-40711",
"datePublished": "2026-06-26T12:31:00.184Z",
"dateReserved": "2026-04-15T05:04:31.837Z",
"dateUpdated": "2026-06-26T12:47:26.963Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
VAR-202210-0666
Vulnerability from variot - Updated: 2023-12-18 13:11Dell Container Storage Modules 1.2 contains an Improper Limitation of a Pathname to a Restricted Directory in goiscsi and gobrick libraries which could lead to OS command injection. A remote unauthenticated attacker could exploit this vulnerability leading to unintentional access to path outside of restricted directory. Dell's container storage modules Exists in a past traversal vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202210-0666",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "container storage modules",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "1.3.0"
},
{
"model": "container storage modules",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "2.0.0"
},
{
"model": "container storage modules",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "container storage modules",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "1.3.0 that\u0027s all 2.0.0"
},
{
"model": "container storage modules",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018705"
},
{
"db": "NVD",
"id": "CVE-2022-34426"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:dell:container_storage_modules:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.0.0",
"versionStartIncluding": "1.3.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-34426"
}
]
},
"cve": "CVE-2022-34426",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-34426",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-34426",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2022-34426",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202210-536",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018705"
},
{
"db": "NVD",
"id": "CVE-2022-34426"
},
{
"db": "NVD",
"id": "CVE-2022-34426"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-536"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell Container Storage Modules 1.2 contains an Improper Limitation of a Pathname to a Restricted Directory in goiscsi and gobrick libraries which could lead to OS command injection. A remote unauthenticated attacker could exploit this vulnerability leading to unintentional access to path outside of restricted directory. Dell\u0027s container storage modules Exists in a past traversal vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-34426"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018705"
},
{
"db": "VULHUB",
"id": "VHN-426742"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-34426",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018705",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202210-536",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-426742",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426742"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018705"
},
{
"db": "NVD",
"id": "CVE-2022-34426"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-536"
}
]
},
"id": "VAR-202210-0666",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-426742"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T13:11:47.851000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Dell Container Storage Modules Repair measures for path traversal vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=210807"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-536"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-22",
"trust": 1.1
},
{
"problemtype": "Path traversal (CWE-22) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426742"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018705"
},
{
"db": "NVD",
"id": "CVE-2022-34426"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.dell.com/support/kbdoc/en-vc/000203352/dsa-2022-259-dell-container-storage-modules-security-update-for-multiple-vulnerabilities"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-34426"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-34426/"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426742"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018705"
},
{
"db": "NVD",
"id": "CVE-2022-34426"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-536"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-426742"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018705"
},
{
"db": "NVD",
"id": "CVE-2022-34426"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-536"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-10-11T00:00:00",
"db": "VULHUB",
"id": "VHN-426742"
},
{
"date": "2023-10-23T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-018705"
},
{
"date": "2022-10-11T17:15:10.977000",
"db": "NVD",
"id": "CVE-2022-34426"
},
{
"date": "2022-10-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-536"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-10-14T00:00:00",
"db": "VULHUB",
"id": "VHN-426742"
},
{
"date": "2023-10-23T02:28:00",
"db": "JVNDB",
"id": "JVNDB-2022-018705"
},
{
"date": "2022-10-14T14:00:49.937000",
"db": "NVD",
"id": "CVE-2022-34426"
},
{
"date": "2022-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-536"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-536"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u0027s \u00a0container\u00a0storage\u00a0modules\u00a0 Past traversal vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018705"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "path traversal",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-536"
}
],
"trust": 0.6
}
}
VAR-202208-2199
Vulnerability from variot - Updated: 2023-12-18 13:06Dell Container Storage Modules 1.2 contains a path traversal vulnerability in goiscsi and gobrick libraries. A remote authenticated malicious user with low privileges could exploit this vulnerability leading to unintentional access to path outside of restricted directory
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-2199",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "container storage modules",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "1.3.0"
},
{
"model": "container storage modules",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "container storage modules",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "1.3.0"
},
{
"model": "container storage modules",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-016138"
},
{
"db": "NVD",
"id": "CVE-2022-34375"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:dell:container_storage_modules:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.3.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-34375"
}
]
},
"cve": "CVE-2022-34375",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "security_alert@emc.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-34375",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-34375",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2022-34375",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-4464",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-016138"
},
{
"db": "NVD",
"id": "CVE-2022-34375"
},
{
"db": "NVD",
"id": "CVE-2022-34375"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-4464"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell Container Storage Modules 1.2 contains a path traversal vulnerability in goiscsi and gobrick libraries. A remote authenticated malicious user with low privileges could exploit this vulnerability leading to unintentional access to path outside of restricted directory",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-34375"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-016138"
},
{
"db": "VULHUB",
"id": "VHN-426691"
},
{
"db": "VULMON",
"id": "CVE-2022-34375"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-34375",
"trust": 3.4
},
{
"db": "JVNDB",
"id": "JVNDB-2022-016138",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202208-4464",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-426691",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2022-34375",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426691"
},
{
"db": "VULMON",
"id": "CVE-2022-34375"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-016138"
},
{
"db": "NVD",
"id": "CVE-2022-34375"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-4464"
}
]
},
"id": "VAR-202208-2199",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-426691"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T13:06:34.880000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Dell Container Storage Modules Repair measures for path traversal vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=206808"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-4464"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-22",
"trust": 1.1
},
{
"problemtype": "Path traversal (CWE-22) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426691"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-016138"
},
{
"db": "NVD",
"id": "CVE-2022-34375"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "https://www.dell.com/support/kbdoc/en-us/000201835/dsa-2022-202-dell-container-storage-modules-security-update-for-multiple-vulnerabilities"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-34375"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-34375/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426691"
},
{
"db": "VULMON",
"id": "CVE-2022-34375"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-016138"
},
{
"db": "NVD",
"id": "CVE-2022-34375"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-4464"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-426691"
},
{
"db": "VULMON",
"id": "CVE-2022-34375"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-016138"
},
{
"db": "NVD",
"id": "CVE-2022-34375"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-4464"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-08-30T00:00:00",
"db": "VULHUB",
"id": "VHN-426691"
},
{
"date": "2022-08-30T00:00:00",
"db": "VULMON",
"id": "CVE-2022-34375"
},
{
"date": "2023-10-02T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-016138"
},
{
"date": "2022-08-30T21:15:08.940000",
"db": "NVD",
"id": "CVE-2022-34375"
},
{
"date": "2022-08-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-4464"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-09-07T00:00:00",
"db": "VULHUB",
"id": "VHN-426691"
},
{
"date": "2022-08-30T00:00:00",
"db": "VULMON",
"id": "CVE-2022-34375"
},
{
"date": "2023-10-02T08:10:00",
"db": "JVNDB",
"id": "JVNDB-2022-016138"
},
{
"date": "2022-09-07T01:17:48.880000",
"db": "NVD",
"id": "CVE-2022-34375"
},
{
"date": "2022-09-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-4464"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-4464"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u0027s \u00a0container\u00a0storage\u00a0modules\u00a0 Past traversal vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-016138"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "path traversal",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-4464"
}
],
"trust": 0.6
}
}
VAR-202208-2167
Vulnerability from variot - Updated: 2023-12-18 12:41Dell Container Storage Modules 1.2 contains an OS command injection in goiscsi and gobrick libraries. A remote authenticated malicious user with low privileges could exploit this vulnerability leading to to execute arbitrary OS commands on the affected system. (DoS) It may be in a state. Designed to provide additional functionality beyond what is available with container storage. The vulnerability stems from the inclusion of operating system command injection in the goiscsi and gobrick libraries
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-2167",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "container storage modules",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "1.3.0"
},
{
"model": "container storage modules",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "container storage modules",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "1.3.0"
},
{
"model": "container storage modules",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015985"
},
{
"db": "NVD",
"id": "CVE-2022-34374"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:dell:container_storage_modules:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.3.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-34374"
}
]
},
"cve": "CVE-2022-34374",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-34374",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-34374",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2022-34374",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-4463",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015985"
},
{
"db": "NVD",
"id": "CVE-2022-34374"
},
{
"db": "NVD",
"id": "CVE-2022-34374"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-4463"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell Container Storage Modules 1.2 contains an OS command injection in goiscsi and gobrick libraries. A remote authenticated malicious user with low privileges could exploit this vulnerability leading to to execute arbitrary OS commands on the affected system. (DoS) It may be in a state. Designed to provide additional functionality beyond what is available with container storage. The vulnerability stems from the inclusion of operating system command injection in the goiscsi and gobrick libraries",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-34374"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015985"
},
{
"db": "VULHUB",
"id": "VHN-426690"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-34374",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015985",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202208-4463",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-426690",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426690"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015985"
},
{
"db": "NVD",
"id": "CVE-2022-34374"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-4463"
}
]
},
"id": "VAR-202208-2167",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-426690"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T12:41:42.699000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Dell Container Storage Modules Fixes for operating system command injection vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=206520"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-4463"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.1
},
{
"problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426690"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015985"
},
{
"db": "NVD",
"id": "CVE-2022-34374"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.dell.com/support/kbdoc/en-us/000201835/dsa-2022-202-dell-container-storage-modules-security-update-for-multiple-vulnerabilities"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-34374"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-34374/"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426690"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015985"
},
{
"db": "NVD",
"id": "CVE-2022-34374"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-4463"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-426690"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-015985"
},
{
"db": "NVD",
"id": "CVE-2022-34374"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-4463"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-08-30T00:00:00",
"db": "VULHUB",
"id": "VHN-426690"
},
{
"date": "2023-09-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-015985"
},
{
"date": "2022-08-30T21:15:08.867000",
"db": "NVD",
"id": "CVE-2022-34374"
},
{
"date": "2022-08-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-4463"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-09-02T00:00:00",
"db": "VULHUB",
"id": "VHN-426690"
},
{
"date": "2023-09-29T08:07:00",
"db": "JVNDB",
"id": "JVNDB-2022-015985"
},
{
"date": "2022-09-02T19:48:48.493000",
"db": "NVD",
"id": "CVE-2022-34374"
},
{
"date": "2022-09-05T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-4463"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-4463"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u0027s \u00a0container\u00a0storage\u00a0modules\u00a0 In \u00a0OS\u00a0 Command injection vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-015985"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-4463"
}
],
"trust": 0.6
}
}
VAR-202210-0919
Vulnerability from variot - Updated: 2023-12-18 11:55Dell Container Storage Modules 1.2 contains an OS Command Injection in goiscsi and gobrick libraries. A remote unauthenticated attacker could exploit this vulnerability leading to modification of intended OS command execution. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202210-0919",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "container storage modules",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "1.3.0"
},
{
"model": "container storage modules",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "2.0.0"
},
{
"model": "container storage modules",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "container storage modules",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "container storage modules",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "1.3.0 that\u0027s all 2.0.0"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018858"
},
{
"db": "NVD",
"id": "CVE-2022-34427"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:dell:container_storage_modules:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.0.0",
"versionStartIncluding": "1.3.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-34427"
}
]
},
"cve": "CVE-2022-34427",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-34427",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-34427",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2022-34427",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202210-529",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018858"
},
{
"db": "NVD",
"id": "CVE-2022-34427"
},
{
"db": "NVD",
"id": "CVE-2022-34427"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-529"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell Container Storage Modules 1.2 contains an OS Command Injection in goiscsi and gobrick libraries. A remote unauthenticated attacker could exploit this vulnerability leading to modification of intended OS command execution. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-34427"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018858"
},
{
"db": "VULHUB",
"id": "VHN-426743"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-34427",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018858",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202210-529",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-426743",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426743"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018858"
},
{
"db": "NVD",
"id": "CVE-2022-34427"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-529"
}
]
},
"id": "VAR-202210-0919",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-426743"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T11:55:28.728000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Dell Container Storage Modules Fixes for operating system command injection vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=210603"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-529"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.1
},
{
"problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426743"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018858"
},
{
"db": "NVD",
"id": "CVE-2022-34427"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.dell.com/support/kbdoc/en-vc/000203352/dsa-2022-259-dell-container-storage-modules-security-update-for-multiple-vulnerabilities"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-34427"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-34427/"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426743"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018858"
},
{
"db": "NVD",
"id": "CVE-2022-34427"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-529"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-426743"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018858"
},
{
"db": "NVD",
"id": "CVE-2022-34427"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-529"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-10-11T00:00:00",
"db": "VULHUB",
"id": "VHN-426743"
},
{
"date": "2023-10-23T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-018858"
},
{
"date": "2022-10-11T17:15:11.060000",
"db": "NVD",
"id": "CVE-2022-34427"
},
{
"date": "2022-10-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-529"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-10-13T00:00:00",
"db": "VULHUB",
"id": "VHN-426743"
},
{
"date": "2023-10-23T08:13:00",
"db": "JVNDB",
"id": "JVNDB-2022-018858"
},
{
"date": "2022-10-13T16:16:37.087000",
"db": "NVD",
"id": "CVE-2022-34427"
},
{
"date": "2022-10-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-529"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-529"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u0027s \u00a0container\u00a0storage\u00a0modules\u00a0 In \u00a0OS\u00a0 Command injection vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018858"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-529"
}
],
"trust": 0.6
}
}