var-202305-1415
Vulnerability from variot

In multiple products of WAGO a vulnerability allows an unauthenticated, remote attacker to create new users and change the device configuration which can result in unintended behaviour, Denial of Service and full system compromise. compact controller 100 firmware, Edge Controller firmware, PFC100 firmware etc. WAGO The product has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202305-1415",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "edge controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "wago",
        "version": "22"
      },
      {
        "model": "touch panel 600 marine",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "wago",
        "version": "22"
      },
      {
        "model": "pfc100",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "wago",
        "version": "23"
      },
      {
        "model": "touch panel 600 advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "wago",
        "version": "22"
      },
      {
        "model": "compact controller 100",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "wago",
        "version": "20"
      },
      {
        "model": "compact controller 100",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "wago",
        "version": "23"
      },
      {
        "model": "pfc100",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "wago",
        "version": "20"
      },
      {
        "model": "touch panel 600 standard",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "wago",
        "version": "22"
      },
      {
        "model": "pfc200",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "wago",
        "version": "20"
      },
      {
        "model": "pfc200",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "wago",
        "version": "23"
      },
      {
        "model": "compact controller 100",
        "scope": null,
        "trust": 0.8,
        "vendor": "wago",
        "version": null
      },
      {
        "model": "touch panel 600 marine",
        "scope": null,
        "trust": 0.8,
        "vendor": "wago",
        "version": null
      },
      {
        "model": "pfc200",
        "scope": null,
        "trust": 0.8,
        "vendor": "wago",
        "version": null
      },
      {
        "model": "edge controller",
        "scope": null,
        "trust": 0.8,
        "vendor": "wago",
        "version": null
      },
      {
        "model": "pfc100",
        "scope": null,
        "trust": 0.8,
        "vendor": "wago",
        "version": null
      },
      {
        "model": "touch panel 600 standard",
        "scope": null,
        "trust": 0.8,
        "vendor": "wago",
        "version": null
      },
      {
        "model": "touch panel 600 advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "wago",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009971"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-1698"
      }
    ]
  },
  "cve": "CVE-2023-1698",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "info@cert.vde.com",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-1698",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2023-009971",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "info@cert.vde.com",
            "id": "CVE-2023-1698",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2023-009971",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009971"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-1698"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "In multiple products of WAGO a vulnerability allows an unauthenticated, remote attacker to create new users and change the device configuration which can result in unintended behaviour, Denial of Service and full system compromise. compact controller 100 firmware, Edge Controller firmware, PFC100 firmware etc. WAGO The product has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-1698"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009971"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-1698"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-1698",
        "trust": 2.7
      },
      {
        "db": "CERT@VDE",
        "id": "VDE-2023-007",
        "trust": 1.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009971",
        "trust": 0.8
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-1698",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-1698"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009971"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-1698"
      }
    ]
  },
  "id": "VAR-202305-1415",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.5522721100000001
  },
  "last_update_date": "2024-08-14T14:54:47.011000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.0
      },
      {
        "problemtype": "OS Command injection (CWE-78) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009971"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-1698"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://cert.vde.com/en/advisories/vde-2023-007/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-1698"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/78.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-1698"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009971"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-1698"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2023-1698"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009971"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-1698"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-05-15T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-1698"
      },
      {
        "date": "2023-12-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-009971"
      },
      {
        "date": "2023-05-15T09:15:09.510000",
        "db": "NVD",
        "id": "CVE-2023-1698"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-05-15T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-1698"
      },
      {
        "date": "2023-12-07T05:39:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-009971"
      },
      {
        "date": "2023-05-26T17:09:45.837000",
        "db": "NVD",
        "id": "CVE-2023-1698"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0WAGO\u00a0 In the product \u00a0OS\u00a0 Command injection vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-009971"
      }
    ],
    "trust": 0.8
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.