SSA-827383
Vulnerability from csaf_siemens - Published: 2026-05-12 00:00 - Updated: 2026-05-12 00:00Summary
SSA-827383: Multiple Vulnerabilities in Teamcenter
Notes
Summary: Siemens Teamcenter is affected by multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality.
Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
5.6 (Medium)
Affected products
Known affected
2 products
Known not affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Teamcenter V2512
Siemens / Teamcenter V2512
|
vers:all/* |
Threats
Impact
Vulnerable component not present
7.3 (High)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Teamcenter V2312
Siemens / Teamcenter V2312
|
vers:intdot/<2312.0014 |
Vendor Fix
fix
|
|
|
Teamcenter V2406
Siemens / Teamcenter V2406
|
vers:intdot/<2406.0012 |
Vendor Fix
fix
|
|
|
Teamcenter V2412
Siemens / Teamcenter V2412
|
vers:intdot/<2412.0009 |
Vendor Fix
fix
|
|
|
Teamcenter V2506
Siemens / Teamcenter V2506
|
vers:intdot/<2506.0005 |
Vendor Fix
fix
|
Known not affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Teamcenter V2512
Siemens / Teamcenter V2512
|
vers:all/* |
Threats
Impact
Vulnerable component not present
7.5 (High)
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Teamcenter V2312
Siemens / Teamcenter V2312
|
vers:intdot/<2312.0014 |
Vendor Fix
fix
|
|
|
Teamcenter V2406
Siemens / Teamcenter V2406
|
vers:intdot/<2406.0012 |
Vendor Fix
fix
|
|
|
Teamcenter V2412
Siemens / Teamcenter V2412
|
vers:intdot/<2412.0009 |
Vendor Fix
fix
|
|
|
Teamcenter V2506
Siemens / Teamcenter V2506
|
vers:intdot/<2506.0005 |
Vendor Fix
fix
|
Known not affected
1 product
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Teamcenter V2512
Siemens / Teamcenter V2512
|
vers:all/* |
Threats
Impact
Vulnerable component not present
References
2 references
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Siemens Teamcenter is affected by multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-827383: Multiple Vulnerabilities in Teamcenter - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-827383.html"
},
{
"category": "self",
"summary": "SSA-827383: Multiple Vulnerabilities in Teamcenter - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-827383.json"
}
],
"title": "SSA-827383: Multiple Vulnerabilities in Teamcenter",
"tracking": {
"current_release_date": "2026-05-12T00:00:00.000Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-827383",
"initial_release_date": "2026-05-12T00:00:00.000Z",
"revision_history": [
{
"date": "2026-05-12T00:00:00.000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2312.0014",
"product": {
"name": "Teamcenter V2312",
"product_id": "1"
}
},
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2312.0009",
"product": {
"name": "Teamcenter V2312",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Teamcenter V2312"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2406.0012",
"product": {
"name": "Teamcenter V2406",
"product_id": "3"
}
},
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2406.0006",
"product": {
"name": "Teamcenter V2406",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Teamcenter V2406"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2412.0009",
"product": {
"name": "Teamcenter V2412",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "Teamcenter V2412"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2506.0005",
"product": {
"name": "Teamcenter V2506",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "Teamcenter V2506"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Teamcenter V2512",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "Teamcenter V2512"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-4367",
"cwe": {
"id": "CWE-754",
"name": "Improper Check for Unusual or Exceptional Conditions"
},
"flags": [
{
"label": "component_not_present",
"product_ids": [
"7"
]
}
],
"notes": [
{
"category": "summary",
"text": "A type check was missing when handling fonts in PDF.js, which would allow arbitrary JavaScript execution in the PDF.js context. This vulnerability affects Firefox \u003c 126, Firefox ESR \u003c 115.11, and Thunderbird \u003c 115.11.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"4"
],
"known_not_affected": [
"7"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2312.0009 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/product/282219420/"
},
{
"category": "vendor_fix",
"details": "Update to V2406.0006 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/product/282219420/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"products": [
"2",
"4"
]
}
],
"threats": [
{
"category": "impact",
"details": "Vulnerable component not present",
"product_ids": [
"7"
]
}
],
"title": "CVE-2024-4367"
},
{
"cve": "CVE-2026-33862",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"flags": [
{
"label": "component_not_present",
"product_ids": [
"7"
]
}
],
"notes": [
{
"category": "summary",
"text": "The affected application does not properly encode or filter user-supplied data. This could allow an attacker to inject malicious code that can be executed by other users when they visit the affected page.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"3",
"5",
"6"
],
"known_not_affected": [
"7"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2312.0014 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/product/282219420/"
},
{
"category": "vendor_fix",
"details": "Update to V2406.0012 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/product/282219420/"
},
{
"category": "vendor_fix",
"details": "Update to V2412.0009 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/product/282219420/"
},
{
"category": "vendor_fix",
"details": "Update to V2506.0005 or later version",
"product_ids": [
"6"
],
"url": "https://support.sw.siemens.com/product/282219420/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"products": [
"1",
"3",
"5",
"6"
]
}
],
"threats": [
{
"category": "impact",
"details": "Vulnerable component not present",
"product_ids": [
"7"
]
}
],
"title": "CVE-2026-33862"
},
{
"cve": "CVE-2026-33893",
"cwe": {
"id": "CWE-798",
"name": "Use of Hard-coded Credentials"
},
"flags": [
{
"label": "component_not_present",
"product_ids": [
"7"
]
}
],
"notes": [
{
"category": "summary",
"text": "The affected application contains hardcoded key which is used for obfuscation stored directly into the application.\r\nThis could allow an attacker to obtain these keys and misuse them to gain unauthorized access.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"3",
"5",
"6"
],
"known_not_affected": [
"7"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2312.0014 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/product/282219420/"
},
{
"category": "vendor_fix",
"details": "Update to V2406.0012 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/product/282219420/"
},
{
"category": "vendor_fix",
"details": "Update to V2412.0009 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/product/282219420/"
},
{
"category": "vendor_fix",
"details": "Update to V2506.0005 or later version",
"product_ids": [
"6"
],
"url": "https://support.sw.siemens.com/product/282219420/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"1",
"3",
"5",
"6"
]
}
],
"threats": [
{
"category": "impact",
"details": "Vulnerable component not present",
"product_ids": [
"7"
]
}
],
"title": "CVE-2026-33893"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…