SSA-686975

Vulnerability from csaf_siemens - Published: 2023-02-14 00:00 - Updated: 2026-08-11 00:00
Summary
SSA-686975: IPU 2022.3 Vulnerabilities in Siemens Industrial Products using Intel CPUs
Notes
Summary: Intel has published information on vulnerabilities in Intel products in November 2022. This advisory lists the related Siemens Industrial products affected by these vulnerabilities that can be patched by applying the corresponding BIOS update ("2022.3 IPU – BIOS Advisory" Intel-SA-00688). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.

Time-of-check time-of-use race condition in the BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.

CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Affected products
Product Identifier Version Remediation
SIMATIC Field PG M5 < V22.01.11
Siemens / SIMATIC Field PG M5
vers:intdot/<22.01.11
Mitigation
Vendor Fix fix
SIMATIC Field PG M6 < V26.01.11
Siemens / SIMATIC Field PG M6
vers:intdot/<26.01.11
Mitigation
Vendor Fix fix
SIMATIC IPC BX-39A < V29.01.03
Siemens / SIMATIC IPC BX-39A
vers:intdot/<29.01.03
Mitigation
Vendor Fix fix
SIMATIC IPC PX-39A < V29.01.03
Siemens / SIMATIC IPC PX-39A
vers:intdot/<29.01.03
Mitigation
Vendor Fix fix
SIMATIC IPC PX-39A PRO < V29.01.03
Siemens / SIMATIC IPC PX-39A PRO
vers:intdot/<29.01.03
Mitigation
Vendor Fix fix
SIMATIC IPC427E < V21.01.19
Siemens / SIMATIC IPC427E
vers:intdot/<21.01.19
Mitigation
Vendor Fix fix
SIMATIC IPC477E < V21.01.19
Siemens / SIMATIC IPC477E
vers:intdot/<21.01.19
Mitigation
Vendor Fix fix
SIMATIC IPC477E PRO < V21.01.19
Siemens / SIMATIC IPC477E PRO
vers:intdot/<21.01.19
Mitigation
Vendor Fix fix
SIMATIC IPC627E < V25.02.14
Siemens / SIMATIC IPC627E
vers:intdot/<25.02.14
Mitigation
Vendor Fix fix
SIMATIC IPC647E < V25.02.14
Siemens / SIMATIC IPC647E
vers:intdot/<25.02.14
Mitigation
Vendor Fix fix
SIMATIC IPC677E < V25.02.14
Siemens / SIMATIC IPC677E
vers:intdot/<25.02.14
Mitigation
Vendor Fix fix
SIMATIC IPC847E < V25.02.14
Siemens / SIMATIC IPC847E
vers:intdot/<25.02.14
Mitigation
Vendor Fix fix
SIMATIC ITP1000
Siemens / SIMATIC ITP1000
vers:all/*
Mitigation
No Fix Planned
SIPLUS IPC427E < V21.01.19
Siemens / SIPLUS IPC427E
vers:intdot/<21.01.19
Mitigation
Vendor Fix fix

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "Intel has published information on vulnerabilities in Intel products in November 2022. This advisory lists the related Siemens Industrial products affected by these vulnerabilities that can be patched by applying the corresponding BIOS update (\"2022.3 IPU \u2013 BIOS Advisory\" Intel-SA-00688).\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-686975: IPU 2022.3 Vulnerabilities in Siemens Industrial Products using Intel CPUs - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-686975.html"
      },
      {
        "category": "self",
        "summary": "SSA-686975: IPU 2022.3 Vulnerabilities in Siemens Industrial Products using Intel CPUs - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-686975.json"
      }
    ],
    "title": "SSA-686975: IPU 2022.3 Vulnerabilities in Siemens Industrial Products using Intel CPUs",
    "tracking": {
      "current_release_date": "2026-08-11T00:00:00.000Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-686975",
      "initial_release_date": "2023-02-14T00:00:00.000Z",
      "revision_history": [
        {
          "date": "2023-02-14T00:00:00.000Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2023-05-09T00:00:00.000Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Added affected products SIMATIC IPC PX-39A and SIMATIC IPC PX-39A pro"
        },
        {
          "date": "2023-07-11T00:00:00.000Z",
          "legacy_version": "1.2",
          "number": "3",
          "summary": "Added fix for SIMATIC Field PG M5"
        },
        {
          "date": "2023-08-08T00:00:00.000Z",
          "legacy_version": "1.3",
          "number": "4",
          "summary": "Added fix for SIMATIC IPC BX-39A, SIMATIC IPC PX-39A, and SIMATIC IPC PX-39A pro"
        },
        {
          "date": "2024-07-09T00:00:00.000Z",
          "legacy_version": "1.4",
          "number": "5",
          "summary": "Added fix for SIMATIC IPC627E / IPC647E / IPC677E / IPC847E"
        },
        {
          "date": "2024-08-13T00:00:00.000Z",
          "legacy_version": "1.5",
          "number": "6",
          "summary": "Added fix for SIMATIC Field PG M6"
        },
        {
          "date": "2025-04-08T00:00:00.000Z",
          "legacy_version": "1.6",
          "number": "7",
          "summary": "Added fix for SIMATIC IPC427E / IPC477E / IPC477E PRO"
        },
        {
          "date": "2026-08-11T00:00:00.000Z",
          "legacy_version": "1.7",
          "number": "8",
          "summary": "Added no fix planned for SIMATIC ITP1000"
        }
      ],
      "status": "interim",
      "version": "8"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c22.01.11",
                "product": {
                  "name": "SIMATIC Field PG M5 \u003c V22.01.11",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Field PG M5"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c26.01.11",
                "product": {
                  "name": "SIMATIC Field PG M6 \u003c V26.01.11",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Field PG M6"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c29.01.03",
                "product": {
                  "name": "SIMATIC IPC BX-39A \u003c V29.01.03",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC BX-39A"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c29.01.03",
                "product": {
                  "name": "SIMATIC IPC PX-39A \u003c V29.01.03",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC PX-39A"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c29.01.03",
                "product": {
                  "name": "SIMATIC IPC PX-39A PRO \u003c V29.01.03",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC PX-39A PRO"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c21.01.19",
                "product": {
                  "name": "SIMATIC IPC427E \u003c V21.01.19",
                  "product_id": "6"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC427E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c21.01.19",
                "product": {
                  "name": "SIMATIC IPC477E \u003c V21.01.19",
                  "product_id": "7"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC477E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c21.01.19",
                "product": {
                  "name": "SIMATIC IPC477E PRO \u003c V21.01.19",
                  "product_id": "8"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC477E PRO"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c25.02.14",
                "product": {
                  "name": "SIMATIC IPC627E \u003c V25.02.14",
                  "product_id": "9"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC627E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c25.02.14",
                "product": {
                  "name": "SIMATIC IPC647E \u003c V25.02.14",
                  "product_id": "10"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC647E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c25.02.14",
                "product": {
                  "name": "SIMATIC IPC677E \u003c V25.02.14",
                  "product_id": "11"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC677E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c25.02.14",
                "product": {
                  "name": "SIMATIC IPC847E \u003c V25.02.14",
                  "product_id": "12"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC847E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC ITP1000",
                  "product_id": "13"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC ITP1000"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c21.01.19",
                "product": {
                  "name": "SIPLUS IPC427E \u003c V21.01.19",
                  "product_id": "14"
                }
              }
            ],
            "category": "product_name",
            "name": "SIPLUS IPC427E"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2022-21198",
      "cwe": {
        "id": "CWE-367",
        "name": "Time-of-check Time-of-use (TOCTOU) Race Condition"
      },
      "notes": [
        {
          "category": "description",
          "text": "Time-of-check time-of-use race condition in the BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14"
          ]
        },
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "13"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V21.01.19 or later version",
          "product_ids": [
            "6",
            "7",
            "8",
            "14"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V22.01.11 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V25.02.14 or later version",
          "product_ids": [
            "9",
            "10",
            "11",
            "12"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V26.01.11 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V29.01.03 or later version",
          "product_ids": [
            "3",
            "4",
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.9,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14"
          ]
        }
      ],
      "title": "CVE-2022-21198"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Loading…