fkie_cve-2024-37995
Vulnerability from fkie_nvd
Published
2024-09-10 10:15
Modified
2024-09-18 15:37
Summary
A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected application improperly handles error while a faulty certificate upload leading to crashing of application. This vulnerability could allow an attacker to disclose sensitive information.
Impacted products
Vendor Product Version
siemens simatic_rf360r_firmware *
siemens simatic_rf360r -
siemens simatic_rf1170r_firmware *
siemens simatic_rf1170r -
siemens simatic_rf1140r_firmware *
siemens simatic_rf1140r -
siemens simatic_reader_rf685r_fcc_firmware *
siemens simatic_reader_rf685r_fcc -
siemens simatic_reader_rf685r_etsi_firmware *
siemens simatic_reader_rf685r_etsi -
siemens simatic_reader_rf685r_cmiit_firmware *
siemens simatic_reader_rf685r_cmiit -
siemens simatic_reader_rf685r_arib_firmware *
siemens simatic_reader_rf685r_arib -
siemens simatic_reader_rf680r_fcc_firmware *
siemens simatic_reader_rf680r_fcc -
siemens simatic_reader_rf680r_etsi_firmware *
siemens simatic_reader_rf680r_etsi -
siemens simatic_reader_rf680r_cmiit_firmware *
siemens simatic_reader_rf680r_cmiit -
siemens simatic_reader_rf680r_arib_firmware *
siemens simatic_reader_rf680r_arib -
siemens simatic_reader_rf650r_fcc_firmware *
siemens simatic_reader_rf650r_fcc -
siemens simatic_reader_rf650r_etsi_firmware *
siemens simatic_reader_rf650r_etsi -
siemens simatic_reader_rf650r_cmiit_firmware *
siemens simatic_reader_rf650r_cmiit -
siemens simatic_reader_rf650r_arib_firmware *
siemens simatic_reader_rf650r_arib -
siemens simatic_reader_rf615r_fcc_firmware *
siemens simatic_reader_rf615r_fcc -
siemens simatic_reader_rf615r_etsi_firmware *
siemens simatic_reader_rf615r_etsi -
siemens simatic_reader_rf615r_cmiit_firmware *
siemens simatic_reader_rf615r_cmiit -
siemens simatic_reader_rf610r_fcc_firmware *
siemens simatic_reader_rf610r_fcc -
siemens simatic_reader_rf610r_etsi_firmware *
siemens simatic_reader_rf610r_etsi -
siemens simatic_reader_rf610r_cmiit_firmware *
siemens simatic_reader_rf610r_cmiit -
siemens simatic_rf188ci_firmware *
siemens simatic_rf188ci -
siemens simatic_rf188c_firmware *
siemens simatic_rf188c -
siemens simatic_rf186ci_firmware *
siemens simatic_rf186ci -
siemens simatic_rf186c_firmware *
siemens simatic_rf186c -
siemens simatic_rf185c_firmware *
siemens simatic_rf185c -
siemens simatic_rf166c_firmware *
siemens simatic_rf166c -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf360r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8930F2B-7C37-4059-85FC-0316B631C860",
              "versionEndExcluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf360r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "63F05227-208B-42C8-8D56-A5D106CAD32F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf1170r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC216594-D56B-454D-BD2C-50631B8C8F9C",
              "versionEndExcluding": "1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf1170r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD8AD128-F6E2-45BD-9098-EC559D193194",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf1140r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "11F4F714-F802-4D13-A965-0A22B80DA9D0",
              "versionEndExcluding": "1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf1140r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1EA20BB5-024E-4389-A0FE-C218E15D31A8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf685r_fcc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F61801B9-80FD-45EC-9A20-5C703CB8BE76",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf685r_fcc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76F5073F-CAE9-4071-9C86-2B29FB529A49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf685r_etsi_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "058EDB3A-31B8-482F-B825-B0A7E192356E",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf685r_etsi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D00C8A81-53EB-425F-A730-AC7505285B73",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf685r_cmiit_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "62FC4D21-B225-4349-A8E8-68780CC465D1",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf685r_cmiit:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3C8FC67-825D-4E55-8341-E449EA98B6AD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf685r_arib_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E84B475-1FB7-4BF1-880B-8DB5137BB941",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf685r_arib:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFAA7370-1B78-4AF8-8358-830460A5E81C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf680r_fcc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "970B3705-6172-4C00-B402-30A7F23C5A08",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf680r_fcc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40D5F6C3-3AC5-40F2-B755-130E24169AB3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf680r_etsi_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D261FBC-1E4C-4016-AD0E-F234EE36F09A",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf680r_etsi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "08729226-19DB-410A-A764-B84E5213839D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf680r_cmiit_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5B465BD-D425-44C7-931C-E6DAABB79B67",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf680r_cmiit:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA13A689-EBB3-47D3-83AB-4EAFCB0CCF14",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf680r_arib_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1B9A6C1-E7AD-46DE-A0EC-E6E03B957A13",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf680r_arib:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC372090-E9D1-4CB7-8CDC-8FA439764359",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf650r_fcc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BBDF6C6-A67A-412F-8ACF-27E3AA0EE8E9",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf650r_fcc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EFD9ED6C-B948-4F73-ADC9-2EA7AFB646C9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf650r_etsi_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "28C49CB8-179A-47B7-9B04-FC214382B643",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf650r_etsi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "70C73C18-EC1D-431A-808F-1C16706B7F26",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf650r_cmiit_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "896E8488-0AB0-4C39-9729-1E42F4C28419",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf650r_cmiit:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "838474F2-85A2-4315-8F0C-B1AAC9B20373",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf650r_arib_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E525612D-8273-42FD-8DAD-D589ED61C9D6",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf650r_arib:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5735D69B-EBA4-4ADD-9D02-AFFBDB14B085",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf615r_fcc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "130361E8-6979-492F-89A3-4EFFF8F5379F",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf615r_fcc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "557BB258-1B9D-457F-9573-85439950C361",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf615r_etsi_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC98A393-C374-4411-94FE-9832CD8690ED",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf615r_etsi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C951AC92-DD7E-4C24-BC38-1D041D81691C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf615r_cmiit_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2AA399AA-B0C4-48D5-B5F5-EE7A65D10A95",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf615r_cmiit:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4C96D63-0711-48F8-ADE2-261FCF306049",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf610r_fcc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C902FA6A-3E5D-471C-8513-27FE8BB5B2DC",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf610r_fcc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F85BC978-9C30-4484-B6D7-B7A4543EFDA5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf610r_etsi_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FA5DA457-347E-4B6B-8003-882BD4D95D64",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf610r_etsi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E0BFFE2B-5843-4A03-A6A7-1098A4FB9A0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf610r_cmiit_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B07B2FDF-E6A5-4E06-9328-01F311E85AF9",
              "versionEndExcluding": "4.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf610r_cmiit:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3CE2417-B29E-4CBD-9A30-3DB5C30771D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf188ci_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84F1472B-A584-4712-BEF7-7B4BDE166CE2",
              "versionEndExcluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf188ci:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0927991-E820-4FC3-9EFE-96E4C9BFCCCD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7DB4915-E989-4085-B201-C5CCC86AB924",
              "versionEndExcluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf186ci_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B280EE0D-F3F9-46E3-949F-109844428C35",
              "versionEndExcluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf186ci:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1EAEB335-BD22-4CEF-A3EA-9D98A09FEBF0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E86AC831-9FB9-4D17-AA06-E68C176F1A23",
              "versionEndExcluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B0933EB-82BE-42BB-978B-C9EC2FE1C795",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A27B28F-A037-4730-A0DD-96BB568F4A58",
              "versionEndExcluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "82494B5E-80EE-47ED-B87E-CF8C8907B6FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf166c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D48EE1B0-3010-44F2-AEF9-A3E35BD03971",
              "versionEndExcluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf166c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "391AD485-A49D-43D0-AAE5-1F58B38D4E22",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions \u003c V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions \u003c V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions \u003c V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions \u003c V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions \u003c V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions \u003c V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions \u003c V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions \u003c V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions \u003c V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions \u003c V2.2). The affected application improperly handles error while a faulty certificate upload leading to crashing of application. This vulnerability could allow an attacker to disclose sensitive information."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (Todas las versiones \u0026lt; V4.2), SIMATIC RF1140R (6GT2831-6CB00) (Todas las versiones \u0026lt; V1.1), SIMATIC RF1170R (6GT2831-6BB00) (Todas las versiones \u0026lt; V1.1), SIMATIC RF166C (6GT2002-0EE20) (Todas las versiones \u0026lt; V2.2), SIMATIC RF185C (6GT2002-0JE10) (Todas las versiones \u0026lt; V2.2), SIMATIC RF186C (6GT2002-0JE20) (Todas las versiones \u0026lt; V2.2), SIMATIC RF186CI (6GT2002-0JE50) (Todas las versiones \u0026lt; V2.2), SIMATIC RF188C (6GT2002-0JE40) (Todas las versiones \u0026lt; V2.2), SIMATIC RF188CI (6GT2002-0JE60) (Todas las versiones \u0026lt; V2.2), SIMATIC RF360R (6GT2801-5BA30) (Todas las versiones \u0026lt; V2.2). La aplicaci\u00f3n afectada maneja incorrectamente el error durante la carga de un certificado defectuoso, lo que provoca el bloqueo de la aplicaci\u00f3n. Esta vulnerabilidad podr\u00eda permitir a un atacante revelar informaci\u00f3n confidencial."
    }
  ],
  "id": "CVE-2024-37995",
  "lastModified": "2024-09-18T15:37:15.130",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 2.7,
          "baseSeverity": "LOW",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 1.4,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "PRESENT",
          "attackVector": "NETWORK",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 2.1,
          "baseSeverity": "LOW",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "HIGH",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "NONE",
          "subsequentSystemConfidentiality": "NONE",
          "subsequentSystemIntegrity": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "LOW",
          "vulnerableSystemConfidentiality": "NONE",
          "vulnerableSystemIntegrity": "NONE"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-09-10T10:15:11.570",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-765405.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-703"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.