fkie_cve-2023-49121
Vulnerability from fkie_nvd
Published
2024-01-09 10:15
Modified
2024-11-21 08:32
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6708C521-2523-4FFE-8D66-01386DF0FAAF",
              "versionEndExcluding": "223.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*",
              "matchCriteriaId": "619B13A0-ADF3-4CC9-A5BD-6C99AE369D43",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*",
              "matchCriteriaId": "E4C4B3EA-853A-4C75-AA5F-319E2802A722",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*",
              "matchCriteriaId": "28C04B66-7E6F-49E6-B7A9-E7357ADE5936",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*",
              "matchCriteriaId": "99A72C67-00A3-499A-9DDC-73AD29672A08",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*",
              "matchCriteriaId": "9C7B34D6-925F-4DB9-8418-962F35FE11C6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*",
              "matchCriteriaId": "211C7830-D4B9-4315-BDE8-F108FF6A609C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*",
              "matchCriteriaId": "52647713-2F45-4D35-B31A-5BB2E15175EF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*",
              "matchCriteriaId": "4378378B-BAEA-4200-9336-936835322DF6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*",
              "matchCriteriaId": "57968030-2B5F-41C1-B8B4-2405C84E3A06",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2023 (todas las versiones "
    }
  ],
  "id": "CVE-2023-49121",
  "lastModified": "2024-11-21T08:32:52.500",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-01-09T10:15:16.760",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.