Summary
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The affected devices contain the hash of the root password in a hard-coded form, which could be exploited for UART console login to the device. An attacker with direct physical access could exploit this vulnerability.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | cpci85_firmware | * | |
siemens | cp-8050_master_module | - | |
siemens | cpci85_firmware | * | |
siemens | cp-8031_master_module | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:cpci85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "59D83EB4-A263-4070-A864-56EB7B120CE2", "versionEndExcluding": "v05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:cp-8050_master_module:-:*:*:*:*:*:*:*", "matchCriteriaId": "E7686251-7011-46F9-9CEB-CC5DADCB5284", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:cpci85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "59D83EB4-A263-4070-A864-56EB7B120CE2", "versionEndExcluding": "v05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:cp-8031_master_module:-:*:*:*:*:*:*:*", "matchCriteriaId": "E84CEC33-3B34-42EF-A698-164AF0343316", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in CP-8031 MASTER MODULE (All versions \u003c CPCI85 V05), CP-8050 MASTER MODULE (All versions \u003c CPCI85 V05). The affected devices contain the hash of the root password in a hard-coded form, which could be exploited for UART console login to the device. An attacker with direct physical access could exploit this vulnerability." } ], "id": "CVE-2023-33920", "lastModified": "2024-11-21T08:06:12.620", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-06-13T09:15:18.677", "references": [ { "source": "productcert@siemens.com", "url": "http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html" }, { "source": "productcert@siemens.com", "url": "http://seclists.org/fulldisclosure/2023/Jul/14" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://packetstormsecurity.com/files/173370/Siemens-A8000-CP-8050-CP-8031-Code-Execution-Command-Injection.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://seclists.org/fulldisclosure/2023/Jul/14" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731916.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.