fkie_cve-2022-23449
Vulnerability from fkie_nvd
Published
2022-04-12 09:15
Modified
2024-11-21 06:48
Severity ?
Summary
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf | Mitigation, Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf | Mitigation, Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_energy_manager_basic | * | |
siemens | simatic_energy_manager_basic | 7.3 | |
siemens | simatic_energy_manager_pro | * | |
siemens | simatic_energy_manager_pro | 7.3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*", "matchCriteriaId": "2BDBCB2C-E9EB-4AF6-B47A-22B27AE41178", "versionEndExcluding": "7.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_energy_manager_basic:7.3:-:*:*:*:*:*:*", "matchCriteriaId": "1BB78E93-7C0A-4F59-B6EA-3D5A681BFE8F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B1E608C-3C6F-45FB-86C9-E99E7F21836D", "versionEndExcluding": "7.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_energy_manager_pro:7.3:-:*:*:*:*:*:*", "matchCriteriaId": "34A11AF9-7F0C-4151-8A4D-A8E1BDCBA525", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.3 Update 1), SIMATIC Energy Manager PRO (All versions \u003c V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC Energy Manager Basic (todas las versiones anteriores a V7.3 Update 1), SIMATIC Energy Manager PRO (todas las versiones anteriores a V7.3 Update 1). Una vulnerabilidad de DLL Hijacking podr\u00eda permitir a un atacante local ejecutar c\u00f3digo con altos privilegios al colocar una DLL maliciosa en uno de los directorios de la ruta de b\u00fasqueda de DLL" } ], "id": "CVE-2022-23449", "lastModified": "2024-11-21T06:48:34.670", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 6.9, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.4, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.3, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-04-12T09:15:14.297", "references": [ { "source": "productcert@siemens.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-427" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-427" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.