A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cp-8000_master_module_with_i\\/o_-25\\/\\+70_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C5EE859-1395-4644-A272-3CA2823E2D26",
              "versionEndExcluding": "16.20",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cp-8000_master_module_with_i\\/o_-25\\/\\+70:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9836DAE0-946B-4B65-98DF-2B82F7F3AF94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cp-8000_master_module_with_i\\/o_-40\\/\\+70_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A9D8EE5-3D2C-420C-9969-0910C6FB8342",
              "versionEndExcluding": "16.20",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cp-8000_master_module_with_i\\/o_-40\\/\\+70:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A6D94AE-9F7E-46F0-92F6-C651E0EE580B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cp-8021_master_module_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B97277D-0D30-4914-BA1E-1E5B07153A52",
              "versionEndExcluding": "16.20",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cp-8021_master_module:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8820652-44D8-43EF-8865-BE8E7967829E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cp-8022_master_module_with_gprs_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEA73D9E-CFAD-4DAF-9E34-51DBD2AF6FD6",
              "versionEndExcluding": "16.20",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cp-8022_master_module_with_gprs:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6815071-0D49-4288-8128-B9A980ECB64C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C (All versions \u003c V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C (All versions \u003c V16.20), CP-8021 MASTER MODULE (All versions \u003c V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions \u003c V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en el M\u00d3DULO MASTER CP-8000 CON E/S -25/+70\u00b0C (Todas las versiones anteriores a V16.20), M\u00d3DULO MASTER CP-8000 CON E/S -40/+70\u00b0C (Todas las versiones anteriores a V16.20), M\u00d3DULO MASTER CP-8021 (Todas las versiones anteriores a V16.20), M\u00d3DULO MASTER CP-8022 CON GPRS (Todas las versiones anteriores a V16.20). El servidor web del sistema afectado permite el acceso a los archivos de registro y datos de diagn\u00f3stico generados por un usuario privilegiado. Un atacante no autenticado podr\u00eda acceder a los archivos conociendo los enlaces de descarga correspondientes"
    }
  ],
  "id": "CVE-2021-45034",
  "lastModified": "2024-11-21T06:31:50.140",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-01-11T12:15:10.143",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://packetstormsecurity.com/files/166743/Siemens-A8000-CP-8050-CP-8031-SICAM-WEB-Missing-File-Download-Missing-Authentication.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Exploit",
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://seclists.org/fulldisclosure/2022/Apr/20"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://packetstormsecurity.com/files/166743/Siemens-A8000-CP-8050-CP-8031-SICAM-WEB-Missing-File-Download-Missing-Authentication.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://seclists.org/fulldisclosure/2022/Apr/20"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324998.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.