fkie_cve-2017-9946
Vulnerability from fkie_nvd
Published
2017-10-23 08:29
Modified
2024-11-21 03:37
Severity ?
Summary
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | apogee_pxc_firmware | * | |
siemens | apogee_pxc | - | |
siemens | apogee_pxc_modular_firmware | * | |
siemens | apogee_pxc_modular | - | |
siemens | talon_tc_compact_firmware | * | |
siemens | talon_tc_compact | - | |
siemens | talon_tc_modular_firmware | * | |
siemens | talon_tc_modular | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:apogee_pxc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2449F533-CA42-44D4-B69E-B7B9F3A4EAD9", "versionEndExcluding": "3.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:apogee_pxc:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73DAA70-4CFB-4E63-ADC7-EC8A93E0BBBB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B1604D4C-3E06-46D0-8D39-0A5BC7CE5A1D", "versionEndExcluding": "3.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:*", "matchCriteriaId": "D9485F0B-03E0-4442-B615-2DA91AE1CD00", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "23756E05-4AD6-4888-AC07-C8E906CA5722", "versionEndExcluding": "3.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:*", "matchCriteriaId": "46D32EF0-8AEC-4594-8928-45F34DC60600", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AB1AF7BE-295B-4386-81F3-B08A1E15DD5F", "versionEndExcluding": "3.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:*", "matchCriteriaId": "00C647D8-1725-42FA-8042-6C413EE67573", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions \u003cV3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Siemens APOGEE PXC y TALON TC BACnet Automation Controllers en todas las versiones anteriores a la V3.5. Un atacante con acceso de red al servidor web integrado (80/tcp y 443/tcp) podr\u00c3\u00ada omitir la autenticaci\u00c3\u00b3n y descargar informaci\u00c3\u00b3n sensble del dispositivo." } ], "id": "CVE-2017-9946", "lastModified": "2024-11-21T03:37:13.760", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2017-10-23T08:29:00.820", "references": [ { "source": "productcert@siemens.com", "tags": [ "Exploit", "Third Party Advisory", "VDB Entry" ], "url": "http://packetstormsecurity.com/files/169544/Siemens-APOGEE-PXC-TALON-TC-Authentication-Bypass.html" }, { "source": "productcert@siemens.com", "tags": [ "Broken Link", "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/101248" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148078.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Broken Link", "Vendor Advisory" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-148078.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory", "VDB Entry" ], "url": "http://packetstormsecurity.com/files/169544/Siemens-APOGEE-PXC-TALON-TC-Authentication-Bypass.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/101248" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148078.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Vendor Advisory" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-148078.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.