CVE-2025-23172 (GCVE-0-2025-23172)
Vulnerability from cvelistv5 – Published: 2025-06-18 23:30 – Updated: 2025-06-23 16:05
VLAI
EPSS
VEX
Summary
The Versa Director SD-WAN orchestration platform includes a Webhook feature for sending notifications to external HTTP endpoints. However, the "Add Webhook" and "Test Webhook" functionalities can be abused by an authenticated user to send crafted HTTP requests to localhost. This can be leveraged to execute commands on behalf of the versa user, who has sudo privileges, potentially leading to privilege escalation or remote code execution.
Exploitation Status:
Versa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers.
Workarounds or Mitigation:
There are no workarounds to disable the GUI option. Versa recommends that Director be upgraded to one of the remediated software versions.
Severity
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-06-23 15:45 UTC
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
References
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23172",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-23T15:45:55.286324Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "CWE-918 Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-23T16:05:24.756Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Director",
"vendor": "Versa",
"versions": [
{
"lessThanOrEqual": "21.2.2",
"status": "affected",
"version": "21.2.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "21.2.3",
"status": "affected",
"version": "21.2.3",
"versionType": "semver"
},
{
"lessThanOrEqual": "22.1.1",
"status": "affected",
"version": "22.1.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "22.1.2",
"status": "affected",
"version": "22.1.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "22.1.3",
"status": "affected",
"version": "22.1.3",
"versionType": "semver"
},
{
"lessThanOrEqual": "22.1.4",
"status": "affected",
"version": "22.1.4",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Versa Director SD-WAN orchestration platform includes a Webhook feature for sending notifications to external HTTP endpoints. However, the \"Add Webhook\" and \"Test Webhook\" functionalities can be abused by an authenticated user to send crafted HTTP requests to localhost. This can be leveraged to execute commands on behalf of the versa user, who has sudo privileges, potentially leading to privilege escalation or remote code execution. \r\n \r\nExploitation Status: \r\n\r\nVersa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers. \r\n\r\nWorkarounds or Mitigation: \r\n\r\nThere are no workarounds to disable the GUI option. Versa recommends that Director be upgraded to one of the remediated software versions."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-18T23:30:51.224Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://security-portal.versa-networks.com/emailbulletins/68526e7bdc94d6b9f2faf71b"
},
{
"url": "https://support.versa-networks.com/support/solutions/articles/23000026708-release-22-1-4"
},
{
"url": "https://support.versa-networks.com/support/solutions/articles/23000026033-release-22-1-3"
},
{
"url": "https://support.versa-networks.com/support/solutions/articles/23000025680-release-22-1-2"
},
{
"url": "https://support.versa-networks.com/support/solutions/articles/23000024323-release-21-2-3"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2025-23172",
"datePublished": "2025-06-18T23:30:51.224Z",
"dateReserved": "2025-01-12T01:00:00.649Z",
"dateUpdated": "2025-06-23T16:05:24.756Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-23172",
"date": "2026-09-26",
"epss": "0.0111",
"percentile": "0.64551"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Director",
"vendor": "Versa",
"versions": [
{
"lessThanOrEqual": "21.2.2",
"status": "affected",
"version": "21.2.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "21.2.3",
"status": "affected",
"version": "21.2.3",
"versionType": "semver"
},
{
"lessThanOrEqual": "22.1.1",
"status": "affected",
"version": "22.1.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "22.1.2",
"status": "affected",
"version": "22.1.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "22.1.3",
"status": "affected",
"version": "22.1.3",
"versionType": "semver"
},
{
"lessThanOrEqual": "22.1.4",
"status": "affected",
"version": "22.1.4",
"versionType": "semver"
}
]
}
],
"source": "support@hackerone.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:versa-networks:versa_director:21.2.2:*:*:*:*:*:*:*",
"matchCriteriaId": "59E2F7B6-200B-4008-A5C6-FD33B05DFF8F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:versa-networks:versa_director:21.2.3:-:*:*:*:*:*:*",
"matchCriteriaId": "BB85151A-2B0A-4C44-A63A-B521A1578A4B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:versa-networks:versa_director:22.1.1:*:*:*:*:*:*:*",
"matchCriteriaId": "BE334340-8D19-4A10-AB58-B9028D96851C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:versa-networks:versa_director:22.1.2:-:*:*:*:*:*:*",
"matchCriteriaId": "2EB7153D-77F2-47E1-BEE0-F2071DF8C21A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:versa-networks:versa_director:22.1.3:-:*:*:*:*:*:*",
"matchCriteriaId": "C0CB9A88-8347-45E9-8E80-F46FE1391B8C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:versa-networks:versa_director:22.1.4:-:*:*:*:*:*:*",
"matchCriteriaId": "272A25D5-8B29-4919-9C8A-D36DE8B592BF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Versa Director SD-WAN orchestration platform includes a Webhook feature for sending notifications to external HTTP endpoints. However, the \"Add Webhook\" and \"Test Webhook\" functionalities can be abused by an authenticated user to send crafted HTTP requests to localhost. This can be leveraged to execute commands on behalf of the versa user, who has sudo privileges, potentially leading to privilege escalation or remote code execution. \r\n \r\nExploitation Status: \r\n\r\nVersa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers. \r\n\r\nWorkarounds or Mitigation: \r\n\r\nThere are no workarounds to disable the GUI option. Versa recommends that Director be upgraded to one of the remediated software versions."
},
{
"lang": "es",
"value": "La plataforma de orquestaci\u00f3n Versa Director SD-WAN incluye una funci\u00f3n de webhook para enviar notificaciones a endpoints HTTP externos. Sin embargo, un usuario autenticado puede abusar de las funciones \"A\u00f1adir webhook\" y \"Probar webhook\" para enviar solicitudes HTTP manipuladas al host local. Esto puede aprovecharse para ejecutar comandos en nombre del usuario de Versa, que tiene privilegios de sudo, lo que podr\u00eda provocar una escalada de privilegios o la ejecuci\u00f3n remota de c\u00f3digo. Estado de explotaci\u00f3n: Versa Networks no tiene constancia de ning\u00fan caso reportado de explotaci\u00f3n de esta vulnerabilidad. Investigadores de seguridad externos han divulgado una prueba de concepto para esta vulnerabilidad. Soluciones alternativas o mitigaci\u00f3n: No existen soluciones alternativas para deshabilitar la opci\u00f3n de la interfaz gr\u00e1fica de usuario (GUI). Versa recomienda actualizar Director a una de las versiones de software corregidas."
}
],
"id": "CVE-2025-23172",
"lastModified": "2026-09-03T18:22:02.170",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "support@hackerone.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-23172",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-23T15:45:55.286324Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-06-19T00:15:21.857",
"references": [
{
"source": "support@hackerone.com",
"tags": [
"Vendor Advisory"
],
"url": "https://security-portal.versa-networks.com/emailbulletins/68526e7bdc94d6b9f2faf71b"
},
{
"source": "support@hackerone.com",
"tags": [
"Product"
],
"url": "https://support.versa-networks.com/support/solutions/articles/23000024323-release-21-2-3"
},
{
"source": "support@hackerone.com",
"tags": [
"Product"
],
"url": "https://support.versa-networks.com/support/solutions/articles/23000025680-release-22-1-2"
},
{
"source": "support@hackerone.com",
"tags": [
"Product"
],
"url": "https://support.versa-networks.com/support/solutions/articles/23000026033-release-22-1-3"
},
{
"source": "support@hackerone.com",
"tags": [
"Product"
],
"url": "https://support.versa-networks.com/support/solutions/articles/23000026708-release-22-1-4"
}
],
"sourceIdentifier": "support@hackerone.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-918"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-06-23T08:38:57+00:00",
"cve": "CVE-2025-23172",
"id": "CVE-2025-23172",
"initial_release_date": "2025-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2025-23172",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-23172.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23172",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-23T15:45:55.286324Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-918",
"description": "CWE-918 Server-Side Request Forgery (SSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-23T15:45:56.371Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Director",
"vendor": "Versa",
"versions": [
{
"lessThanOrEqual": "21.2.2",
"status": "affected",
"version": "21.2.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "21.2.3",
"status": "affected",
"version": "21.2.3",
"versionType": "semver"
},
{
"lessThanOrEqual": "22.1.1",
"status": "affected",
"version": "22.1.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "22.1.2",
"status": "affected",
"version": "22.1.2",
"versionType": "semver"
},
{
"lessThanOrEqual": "22.1.3",
"status": "affected",
"version": "22.1.3",
"versionType": "semver"
},
{
"lessThanOrEqual": "22.1.4",
"status": "affected",
"version": "22.1.4",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Versa Director SD-WAN orchestration platform includes a Webhook feature for sending notifications to external HTTP endpoints. However, the \"Add Webhook\" and \"Test Webhook\" functionalities can be abused by an authenticated user to send crafted HTTP requests to localhost. This can be leveraged to execute commands on behalf of the versa user, who has sudo privileges, potentially leading to privilege escalation or remote code execution. \r\n \r\nExploitation Status: \r\n\r\nVersa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers. \r\n\r\nWorkarounds or Mitigation: \r\n\r\nThere are no workarounds to disable the GUI option. Versa recommends that Director be upgraded to one of the remediated software versions."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-18T23:30:51.224Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://security-portal.versa-networks.com/emailbulletins/68526e7bdc94d6b9f2faf71b"
},
{
"url": "https://support.versa-networks.com/support/solutions/articles/23000026708-release-22-1-4"
},
{
"url": "https://support.versa-networks.com/support/solutions/articles/23000026033-release-22-1-3"
},
{
"url": "https://support.versa-networks.com/support/solutions/articles/23000025680-release-22-1-2"
},
{
"url": "https://support.versa-networks.com/support/solutions/articles/23000024323-release-21-2-3"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2025-23172",
"datePublished": "2025-06-18T23:30:51.224Z",
"dateReserved": "2025-01-12T01:00:00.649Z",
"dateUpdated": "2025-06-23T16:05:24.756Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…