cve-2024-9489
Vulnerability from cvelistv5
Published
2024-10-29 21:44
Modified
2025-02-03 18:04
Severity ?
EPSS score ?
Summary
A maliciously crafted DWG file when parsed in ACAD.exe through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process.
References
▼ | URL | Tags | |
---|---|---|---|
psirt@autodesk.com | https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0021 | Vendor Advisory |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Autodesk | AutoCAD |
Version: 2025 < 2025.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-9489", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-30T13:51:32.196438Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-30T15:01:17.148Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "cpe": [ "cpe:2.3:a:autodesk:autocad:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "AutoCAD", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:autocad_lt:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "AutoCAD LT", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:autocad_architecture:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "AutoCAD Architecture", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:autocad_electrical:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "AutoCAD Electrical", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:autocad_mechanical:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "AutoCAD Mechanical", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:autocad_mep:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "AutoCAD MEP", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:autocad_plant_3d:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "AutoCAD Plant 3D", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:autocad_civil_3d:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "Civil 3D", "vendor": "AutoCAD", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:autocad_advance_steel:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "Advance Steel", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:dwg_trueview:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "DWG TrueView", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:infrastructure_parts_editor:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "Infrastructure Parts Editor", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:inventor:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "Inventor", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:navisworks_manage:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "Navisworks Manage", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:navisworks_simulate:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "Navisworks Simulate", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:revit:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "Revit", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] }, { "cpe": [ "cpe:2.3:a:autodesk:vault_basic_client:2025:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "Vault Basic Client", "vendor": "Autodesk", "versions": [ { "lessThan": "2025.1.1", "status": "affected", "version": "2025", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A maliciously crafted DWG file when parsed in ACAD.exe through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process." } ], "value": "A maliciously crafted DWG file when parsed in ACAD.exe through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process." } ], "impacts": [ { "capecId": "CAPEC-100", "descriptions": [ { "lang": "en", "value": "CAPEC-100 Overflow Buffers" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-03T18:04:44.972Z", "orgId": "7e40ea87-bc65-4944-9723-dd79dd760601", "shortName": "autodesk" }, "references": [ { "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0021" } ], "source": { "discovery": "UNKNOWN" }, "title": "Autodesk AutoCAD DWG File Parsing Memory Corruption Code Execution Vulnerability", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "7e40ea87-bc65-4944-9723-dd79dd760601", "assignerShortName": "autodesk", "cveId": "CVE-2024-9489", "datePublished": "2024-10-29T21:44:39.027Z", "dateReserved": "2024-10-03T18:19:18.769Z", "dateUpdated": "2025-02-03T18:04:44.972Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-9489\",\"sourceIdentifier\":\"psirt@autodesk.com\",\"published\":\"2024-10-29T22:15:08.703\",\"lastModified\":\"2024-11-01T16:27:25.937\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A maliciously crafted DWG file when parsed in ACAD.exe through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Un archivo DWG creado con fines malintencionados, al analizarse en ACAD.exe a trav\u00e9s de Autodesk AutoCAD, puede provocar una vulnerabilidad de corrupci\u00f3n de memoria. Un actor malintencionado puede aprovechar esta vulnerabilidad para provocar un bloqueo, escribir datos confidenciales o ejecutar c\u00f3digo arbitrario en el contexto del proceso actual.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@autodesk.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"psirt@autodesk.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"8108219C-2977-47DF-8818-F7360E0AEA31\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_advance_steel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"583DCDB2-2170-4A06-B532-31886E2F1B12\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"A993F4D4-A2BA-42F7-B840-36BCCE6FF725\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_civil_3d:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"F4C616A7-A68D-42C5-88EB-9A6FE2C53116\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"F08AC00E-D022-401C-9A0F-55C5943591C8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"889BB63A-C63B-4558-B1D6-49F76E1BB2C1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"FA51DA68-070A-40F6-BF50-DBC31DCDD224\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"9DF22F44-1D3F-4F18-9835-8E0AE817377C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"C1E9CD44-2AD4-4145-9816-60D0BD468D37\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:dwg_trueview:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2025\",\"versionEndExcluding\":\"2025.1.1\",\"matchCriteriaId\":\"B6F2BC95-E948-4B22-9765-D5008ABD88E8\"}]}]}],\"references\":[{\"url\":\"https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0021\",\"source\":\"psirt@autodesk.com\",\"tags\":[\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-9489\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-30T13:51:32.196438Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-30T14:02:18.360Z\"}}], \"cna\": {\"title\": \"Autodesk AutoCAD DWG File Parsing Memory Corruption Code Execution Vulnerability\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-100\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-100 Overflow Buffers\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"cpe\": [\"cpe:2.3:a:autodesk:autocad:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"AutoCAD\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:autocad_lt:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"AutoCAD LT\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:autocad_architecture:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"AutoCAD Architecture\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:autocad_electrical:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"AutoCAD Electrical\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:autocad_mechanical:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"AutoCAD Mechanical\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:autocad_mep:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"AutoCAD MEP\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:autocad_plant_3d:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"AutoCAD Plant 3D\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:autocad_civil_3d:2025:*:*:*:*:*:*:*\"], \"vendor\": \"AutoCAD\", \"product\": \"Civil 3D\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:autocad_advance_steel:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"Advance Steel\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:dwg_trueview:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"DWG TrueView\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:infrastructure_parts_editor:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"Infrastructure Parts Editor\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:inventor:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"Inventor\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:navisworks_manage:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"Navisworks Manage\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:navisworks_simulate:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"Navisworks Simulate\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:revit:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"Revit\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"cpe\": [\"cpe:2.3:a:autodesk:vault_basic_client:2025:*:*:*:*:*:*:*\"], \"vendor\": \"Autodesk\", \"product\": \"Vault Basic Client\", \"versions\": [{\"status\": \"affected\", \"version\": \"2025\", \"lessThan\": \"2025.1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.autodesk.com/trust/security-advisories/adsk-sa-2024-0021\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A maliciously crafted DWG file when parsed in ACAD.exe through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"A maliciously crafted DWG file when parsed in ACAD.exe through Autodesk AutoCAD can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to cause a crash, write sensitive data, or execute arbitrary code in the context of the current process.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-119\", \"description\": \"CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer\"}]}], \"providerMetadata\": {\"orgId\": \"7e40ea87-bc65-4944-9723-dd79dd760601\", \"shortName\": \"autodesk\", \"dateUpdated\": \"2025-02-03T18:04:44.972Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2024-9489\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-03T18:04:44.972Z\", \"dateReserved\": \"2024-10-03T18:19:18.769Z\", \"assignerOrgId\": \"7e40ea87-bc65-4944-9723-dd79dd760601\", \"datePublished\": \"2024-10-29T21:44:39.027Z\", \"assignerShortName\": \"autodesk\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.