CVE-2024-3701 (GCVE-0-2024-3701)
Vulnerability from cvelistv5 – Published: 2024-04-15 07:56 – Updated: 2024-08-21 03:07
VLAI
Title
Improper Authentication in com.transsion.kolun.aiservice
Summary
The system application (com.transsion.kolun.aiservice) component does not perform an authentication check, which allows attackers to perform malicious exploitations and affect system services.
Severity
9.8 (Critical)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| TECNO | com.transsion.kolun.aiservice |
Affected:
13.0.0
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tecno-mobile:hios:13.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hios",
"vendor": "tecno-mobile",
"versions": [
{
"status": "affected",
"version": "13.0.0"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-3701",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-31T15:10:10.634794Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T15:16:51.326Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:20:01.065Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://security.tecno.com/SRC/blogdetail/236?lang=en_US"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.tecno.com/SRC/securityUpdates?type=SA"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"HiOS"
],
"product": "com.transsion.kolun.aiservice",
"vendor": "TECNO",
"versions": [
{
"status": "affected",
"version": "13.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The system application (com.transsion.kolun.aiservice) component \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003edoes not perform an authentication check\u003c/span\u003e, which allows attackers to perform malicious exploitations and affect system services."
}
],
"value": "The system application (com.transsion.kolun.aiservice) component does not perform an authentication check, which allows attackers to perform malicious exploitations and affect system services."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T03:07:48.011Z",
"orgId": "907edf6c-bf03-423e-ab1a-8da27e1aa1ea",
"shortName": "TECNOMobile"
},
"references": [
{
"url": "https://security.tecno.com/SRC/blogdetail/236?lang=en_US"
},
{
"url": "https://security.tecno.com/SRC/securityUpdates?type=SA"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Improper Authentication in com.transsion.kolun.aiservice",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "907edf6c-bf03-423e-ab1a-8da27e1aa1ea",
"assignerShortName": "TECNOMobile",
"cveId": "CVE-2024-3701",
"datePublished": "2024-04-15T07:56:07.521Z",
"dateReserved": "2024-04-12T08:54:13.659Z",
"dateUpdated": "2024-08-21T03:07:48.011Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-3701",
"date": "2026-05-29",
"epss": "0.00484",
"percentile": "0.65564"
},
"fkie_nvd": {
"descriptions": "[{\"lang\": \"en\", \"value\": \"The system application (com.transsion.kolun.aiservice) component does not perform an authentication check, which allows attackers to perform malicious exploitations and affect system services.\"}, {\"lang\": \"es\", \"value\": \"El componente de la aplicaci\\u00f3n del sistema (com.transsion.kolun.aiservice) no realiza una verificaci\\u00f3n de autenticaci\\u00f3n, lo que permite a los atacantes realizar explotaciones maliciosas y afectar los servicios del sistema.\"}]",
"id": "CVE-2024-3701",
"lastModified": "2024-11-21T09:30:12.500",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}]}",
"published": "2024-04-15T08:15:18.377",
"references": "[{\"url\": \"https://security.tecno.com/SRC/blogdetail/236?lang=en_US\", \"source\": \"907edf6c-bf03-423e-ab1a-8da27e1aa1ea\"}, {\"url\": \"https://security.tecno.com/SRC/securityUpdates?type=SA\", \"source\": \"907edf6c-bf03-423e-ab1a-8da27e1aa1ea\"}, {\"url\": \"https://security.tecno.com/SRC/blogdetail/236?lang=en_US\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://security.tecno.com/SRC/securityUpdates?type=SA\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "907edf6c-bf03-423e-ab1a-8da27e1aa1ea",
"vulnStatus": "Awaiting Analysis",
"weaknesses": "[{\"source\": \"907edf6c-bf03-423e-ab1a-8da27e1aa1ea\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}, {\"source\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-287\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-3701\",\"sourceIdentifier\":\"907edf6c-bf03-423e-ab1a-8da27e1aa1ea\",\"published\":\"2024-04-15T08:15:18.377\",\"lastModified\":\"2025-06-17T20:58:01.017\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The system application (com.transsion.kolun.aiservice) component does not perform an authentication check, which allows attackers to perform malicious exploitations and affect system services.\"},{\"lang\":\"es\",\"value\":\"El componente de la aplicaci\u00f3n del sistema (com.transsion.kolun.aiservice) no realiza una verificaci\u00f3n de autenticaci\u00f3n, lo que permite a los atacantes realizar explotaciones maliciosas y afectar los servicios del sistema.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"907edf6c-bf03-423e-ab1a-8da27e1aa1ea\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tecno:hios:13.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A463C431-4A55-44BB-ABA9-73891B31D4E7\"}]}]}],\"references\":[{\"url\":\"https://security.tecno.com/SRC/blogdetail/236?lang=en_US\",\"source\":\"907edf6c-bf03-423e-ab1a-8da27e1aa1ea\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://security.tecno.com/SRC/securityUpdates?type=SA\",\"source\":\"907edf6c-bf03-423e-ab1a-8da27e1aa1ea\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://security.tecno.com/SRC/blogdetail/236?lang=en_US\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://security.tecno.com/SRC/securityUpdates?type=SA\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://security.tecno.com/SRC/blogdetail/236?lang=en_US\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://security.tecno.com/SRC/securityUpdates?type=SA\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T20:20:01.065Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-3701\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-31T15:10:10.634794Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:tecno-mobile:hios:13.0.0:*:*:*:*:*:*:*\"], \"vendor\": \"tecno-mobile\", \"product\": \"hios\", \"versions\": [{\"status\": \"affected\", \"version\": \"13.0.0\"}], \"defaultStatus\": \"unknown\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-287\", \"description\": \"CWE-287 Improper Authentication\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-31T15:16:06.093Z\"}}], \"cna\": {\"title\": \"Improper Authentication in com.transsion.kolun.aiservice\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"affected\": [{\"vendor\": \"TECNO\", \"product\": \"com.transsion.kolun.aiservice\", \"versions\": [{\"status\": \"affected\", \"version\": \"13.0.0\"}], \"platforms\": [\"HiOS\"], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://security.tecno.com/SRC/blogdetail/236?lang=en_US\"}, {\"url\": \"https://security.tecno.com/SRC/securityUpdates?type=SA\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The system application (com.transsion.kolun.aiservice) component does not perform an authentication check, which allows attackers to perform malicious exploitations and affect system services.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"The system application (com.transsion.kolun.aiservice) component \u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003edoes not perform an authentication check\u003c/span\u003e, which allows attackers to perform malicious exploitations and affect system services.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-306\", \"description\": \"CWE-306 Missing Authentication for Critical Function\"}]}], \"providerMetadata\": {\"orgId\": \"907edf6c-bf03-423e-ab1a-8da27e1aa1ea\", \"shortName\": \"TECNOMobile\", \"dateUpdated\": \"2024-08-21T03:07:48.011Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-3701\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-21T03:07:48.011Z\", \"dateReserved\": \"2024-04-12T08:54:13.659Z\", \"assignerOrgId\": \"907edf6c-bf03-423e-ab1a-8da27e1aa1ea\", \"datePublished\": \"2024-04-15T07:56:07.521Z\", \"assignerShortName\": \"TECNOMobile\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…