CVE-2024-31146 (GCVE-0-2024-31146)
Vulnerability from cvelistv5 – Published: 2024-09-25 10:31 – Updated: 2024-09-25 13:24
VLAI
EPSS
VEX
Title
PCI device pass-through with shared resources
Summary
When multiple devices share resources and one of them is to be passed
through to a guest, security of the entire system and of respective
guests individually cannot really be guaranteed without knowing
internals of any of the involved guests. Therefore such a configuration
cannot really be security-supported, yet making that explicit was so far
missing.
Resources the sharing of which is known to be problematic include, but
are not limited to
- - PCI Base Address Registers (BARs) of multiple devices mapping to the
same page (4k on x86),
- - INTx lines.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-25 13:14 UTC
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
Impacted products
Date Public
2024-08-13 12:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-09-25T11:02:55.207Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://xenbits.xen.org/xsa/advisory-461.html"
},
{
"url": "http://www.openwall.com/lists/oss-security/2024/08/14/3"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:xen:xen:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "xen",
"vendor": "xen",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-31146",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-25T13:14:46.996097Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T13:24:47.409Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Xen",
"vendor": "Xen",
"versions": [
{
"status": "unknown",
"version": "consult Xen advisory XSA-461"
}
]
}
],
"configurations": [
{
"lang": "en",
"value": "All systems making use of PCI pass-through are in principle vulnerable,\nwhen any kind of resource is shared. Just to re-iterate, even in the\nabsence of resource sharing caveats apply to passing through of PCI\ndevices to entirely untrusted guests."
}
],
"datePublic": "2024-08-13T12:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "When multiple devices share resources and one of them is to be passed\nthrough to a guest, security of the entire system and of respective\nguests individually cannot really be guaranteed without knowing\ninternals of any of the involved guests. Therefore such a configuration\ncannot really be security-supported, yet making that explicit was so far\nmissing.\n\nResources the sharing of which is known to be problematic include, but\nare not limited to\n- - PCI Base Address Registers (BARs) of multiple devices mapping to the\n same page (4k on x86),\n- - INTx lines."
}
],
"impacts": [
{
"descriptions": [
{
"lang": "en",
"value": "The precise effects when shared resources are in use are system, device,\nguest, and resource specific. None of privilege escalation, information\nleaks, or Denial of Service (DoS) can be ruled out."
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T10:31:51.154Z",
"orgId": "23aa2041-22e1-471f-9209-9b7396fa234f",
"shortName": "XEN"
},
"references": [
{
"url": "https://xenbits.xenproject.org/xsa/advisory-461.html"
}
],
"title": "PCI device pass-through with shared resources",
"workarounds": [
{
"lang": "en",
"value": "Passing through only SR-IOV virtual functions or devices with well-\nseparated resources will avoid this particular vulnerability. Passing\nthrough all devices sharing a given resource to the same guest will also\navoid this particular vulnerability."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "23aa2041-22e1-471f-9209-9b7396fa234f",
"assignerShortName": "XEN",
"cveId": "CVE-2024-31146",
"datePublished": "2024-09-25T10:31:51.154Z",
"dateReserved": "2024-03-28T18:14:12.893Z",
"dateUpdated": "2024-09-25T13:24:47.409Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-31146",
"date": "2026-09-15",
"epss": "0.00235",
"percentile": "0.14617"
},
"fkie_nvd": {
"descriptions": "[{\"lang\": \"en\", \"value\": \"When multiple devices share resources and one of them is to be passed\\nthrough to a guest, security of the entire system and of respective\\nguests individually cannot really be guaranteed without knowing\\ninternals of any of the involved guests. Therefore such a configuration\\ncannot really be security-supported, yet making that explicit was so far\\nmissing.\\n\\nResources the sharing of which is known to be problematic include, but\\nare not limited to\\n- - PCI Base Address Registers (BARs) of multiple devices mapping to the\\n same page (4k on x86),\\n- - INTx lines.\"}, {\"lang\": \"es\", \"value\": \"Cuando varios dispositivos comparten recursos y uno de ellos debe pasarse a un invitado, la seguridad de todo el sistema y de los respectivos invitados individualmente no se puede garantizar realmente sin conocer los detalles internos de cualquiera de los invitados involucrados. Por lo tanto, una configuraci\\u00f3n de este tipo no puede realmente ser compatible con la seguridad, aunque hasta ahora no se hab\\u00eda hecho expl\\u00edcita. Los recursos cuyo uso compartido se sabe que es problem\\u00e1tico incluyen, entre otros: - Registros de direcci\\u00f3n base PCI (BAR) de varios dispositivos que se asignan a la misma p\\u00e1gina (4k en x86), - L\\u00edneas INTx.\"}]",
"id": "CVE-2024-31146",
"lastModified": "2024-11-21T09:12:55.600",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.8, \"impactScore\": 6.0}]}",
"published": "2024-09-25T11:15:12.220",
"references": "[{\"url\": \"https://xenbits.xenproject.org/xsa/advisory-461.html\", \"source\": \"security@xen.org\"}, {\"url\": \"http://www.openwall.com/lists/oss-security/2024/08/14/3\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"http://xenbits.xen.org/xsa/advisory-461.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "security@xen.org",
"vulnStatus": "Awaiting Analysis",
"weaknesses": "[{\"source\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-400\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-31146\",\"sourceIdentifier\":\"security@xen.org\",\"published\":\"2024-09-25T11:15:12.220\",\"lastModified\":\"2026-06-17T07:27:52.223\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"When multiple devices share resources and one of them is to be passed\\nthrough to a guest, security of the entire system and of respective\\nguests individually cannot really be guaranteed without knowing\\ninternals of any of the involved guests. Therefore such a configuration\\ncannot really be security-supported, yet making that explicit was so far\\nmissing.\\n\\nResources the sharing of which is known to be problematic include, but\\nare not limited to\\n- - PCI Base Address Registers (BARs) of multiple devices mapping to the\\n same page (4k on x86),\\n- - INTx lines.\"},{\"lang\":\"es\",\"value\":\"Cuando varios dispositivos comparten recursos y uno de ellos debe pasarse a un invitado, la seguridad de todo el sistema y de los respectivos invitados individualmente no se puede garantizar realmente sin conocer los detalles internos de cualquiera de los invitados involucrados. Por lo tanto, una configuraci\u00f3n de este tipo no puede realmente ser compatible con la seguridad, aunque hasta ahora no se hab\u00eda hecho expl\u00edcita. Los recursos cuyo uso compartido se sabe que es problem\u00e1tico incluyen, entre otros: - Registros de direcci\u00f3n base PCI (BAR) de varios dispositivos que se asignan a la misma p\u00e1gina (4k en x86), - L\u00edneas INTx.\"}],\"affected\":[{\"source\":\"security@xen.org\",\"affectedData\":[{\"vendor\":\"Xen\",\"product\":\"Xen\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"consult Xen advisory XSA-461\",\"status\":\"unknown\"}]}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"affectedData\":[{\"vendor\":\"xen\",\"product\":\"xen\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:xen:xen:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThanOrEqual\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.8,\"impactScore\":6.0}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2024-09-25T13:14:46.996097Z\",\"id\":\"CVE-2024-31146\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"total\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:xen:xen:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BFA1950D-1D9F-4401-AA86-CF3028EFD286\"}]}]}],\"references\":[{\"url\":\"https://xenbits.xenproject.org/xsa/advisory-461.html\",\"source\":\"security@xen.org\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.openwall.com/lists/oss-security/2024/08/14/3\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"http://xenbits.xen.org/xsa/advisory-461.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}",
"redhat_vex": {
"current_release_date": "2025-11-21T14:34:36+00:00",
"cve": "CVE-2024-31146",
"id": "CVE-2024-31146",
"initial_release_date": "2024-09-25T11:15:12.220000+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "xen: PCI device pass-through with shared resources",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-31146.json",
"version": "3"
},
"suse_vex": {
"aggregate_severity": "moderate",
"current_release_date": "2026-08-29T01:56:25Z",
"cve": "CVE-2024-31146",
"id": "CVE-2024-31146",
"initial_release_date": "2024-08-15T02:03:45Z",
"product_status:known_affected": "371",
"product_status:recommended": "145",
"source": "SUSE CSAF VEX",
"status": "interim",
"title": "SUSE CVE CVE-2024-31146",
"url": "https://ftp.suse.com/pub/projects/security/csaf-vex/cve-2024-31146.json",
"version": "46"
},
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"http://xenbits.xen.org/xsa/advisory-461.html\"}, {\"url\": \"http://www.openwall.com/lists/oss-security/2024/08/14/3\"}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-09-25T11:02:55.207Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-31146\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-25T13:14:46.996097Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:xen:xen:-:*:*:*:*:*:*:*\"], \"vendor\": \"xen\", \"product\": \"xen\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"*\"}], \"defaultStatus\": \"unknown\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-400\", \"description\": \"CWE-400 Uncontrolled Resource Consumption\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-25T13:24:24.913Z\"}}], \"cna\": {\"title\": \"PCI device pass-through with shared resources\", \"impacts\": [{\"descriptions\": [{\"lang\": \"en\", \"value\": \"The precise effects when shared resources are in use are system, device,\\nguest, and resource specific. None of privilege escalation, information\\nleaks, or Denial of Service (DoS) can be ruled out.\"}]}], \"affected\": [{\"vendor\": \"Xen\", \"product\": \"Xen\", \"versions\": [{\"status\": \"unknown\", \"version\": \"consult Xen advisory XSA-461\"}], \"defaultStatus\": \"unknown\"}], \"datePublic\": \"2024-08-13T12:00:00Z\", \"references\": [{\"url\": \"https://xenbits.xenproject.org/xsa/advisory-461.html\"}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"Passing through only SR-IOV virtual functions or devices with well-\\nseparated resources will avoid this particular vulnerability. Passing\\nthrough all devices sharing a given resource to the same guest will also\\navoid this particular vulnerability.\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"When multiple devices share resources and one of them is to be passed\\nthrough to a guest, security of the entire system and of respective\\nguests individually cannot really be guaranteed without knowing\\ninternals of any of the involved guests. Therefore such a configuration\\ncannot really be security-supported, yet making that explicit was so far\\nmissing.\\n\\nResources the sharing of which is known to be problematic include, but\\nare not limited to\\n- - PCI Base Address Registers (BARs) of multiple devices mapping to the\\n same page (4k on x86),\\n- - INTx lines.\"}], \"configurations\": [{\"lang\": \"en\", \"value\": \"All systems making use of PCI pass-through are in principle vulnerable,\\nwhen any kind of resource is shared. Just to re-iterate, even in the\\nabsence of resource sharing caveats apply to passing through of PCI\\ndevices to entirely untrusted guests.\"}], \"providerMetadata\": {\"orgId\": \"23aa2041-22e1-471f-9209-9b7396fa234f\", \"shortName\": \"XEN\", \"dateUpdated\": \"2024-09-25T10:31:51.154Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-31146\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-09-25T13:24:47.409Z\", \"dateReserved\": \"2024-03-28T18:14:12.893Z\", \"assignerOrgId\": \"23aa2041-22e1-471f-9209-9b7396fa234f\", \"datePublished\": \"2024-09-25T10:31:51.154Z\", \"assignerShortName\": \"XEN\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Loading…
Loading…