Action not permitted
Modal body text goes here.
Modal Title
Modal Body
cve-2023-26293
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Totally Integrated Automation Portal (TIA Portal) V15 |
Version: 0 < * |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:46:23.955Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-26293", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-25T21:18:47.172683Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-25T21:18:55.576Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "V16 Update 7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 1", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions \u003c V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20: Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-13T07:50:28.798Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-116924.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-26293", "datePublished": "2023-04-11T09:03:02.235Z", "dateReserved": "2023-02-21T17:13:44.190Z", "dateUpdated": "2024-11-25T21:18:55.576Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-26293\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-04-11T10:15:18.157\",\"lastModified\":\"2024-11-21T07:51:04.510\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions \u003c V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":1.8,\"impactScore\":5.5},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tia_portal:15:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FB7DAF87-8685-402D-B8AF-30E3DBC8B37C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tia_portal:16:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"85B6CBCC-CBF6-45F3-A475-FF154208E58C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tia_portal:17:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"85EDE398-4E18-4F39-9F00-66E9EDB17AD7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tia_portal:17:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"7C4DFB46-947A-4156-B760-5754D3A502B7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tia_portal:17:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"4A46017D-5AF4-4063-92E8-83228CCDEB45\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tia_portal:17:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"903EA460-9F1F-4BB1-AAF4-9B17A864892A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tia_portal:17:update4:*:*:*:*:*:*\",\"matchCriteriaId\":\"D63A193B-18EB-4399-8528-BC58C88CB19C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tia_portal:17:update5:*:*:*:*:*:*\",\"matchCriteriaId\":\"931BB5EB-D243-4E06-844B-567B899905F2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tia_portal:18:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"50C20804-6D7D-49AB-8789-625CA57C077B\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-116924.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T11:46:23.955Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-26293\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-25T21:18:47.172683Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-25T21:18:51.854Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"Totally Integrated Automation Portal (TIA Portal) V15\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Totally Integrated Automation Portal (TIA Portal) V16\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V16 Update 7\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Totally Integrated Automation Portal (TIA Portal) V17\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V17 Update 6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Totally Integrated Automation Portal (TIA Portal) V18\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V18 Update 1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-116924.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions \u003c V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-20\", \"description\": \"CWE-20: Improper Input Validation\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2024-08-13T07:50:28.798Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2023-26293\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-25T21:18:55.576Z\", \"dateReserved\": \"2023-02-21T17:13:44.190Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2023-04-11T09:03:02.235Z\", \"assignerShortName\": \"siemens\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
SSA-116924
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "TIA Portal contains a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-116924.html" }, { "category": "self", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-116924.json" } ], "title": "SSA-116924: Path Traversal Vulnerability in TIA Portal", "tracking": { "current_release_date": "2024-08-13T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-116924", "initial_release_date": "2023-04-11T00:00:00Z", "revision_history": [ { "date": "2023-04-11T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2023-05-09T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added fix for Totally Integrated Automation Portal (TIA Portal) V17" }, { "date": "2024-08-13T00:00:00Z", "legacy_version": "1.2", "number": "3", "summary": "Added fix for Totally Integrated Automation Portal (TIA Portal) V16" } ], "status": "interim", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V15", "product_id": "1" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V15" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V16 Update 7", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V16", "product_id": "2" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V16" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V17 Update 6", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V17", "product_id": "3" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V17" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V18 Update 1", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V18", "product_id": "4" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V18" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-26293", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted project files or PC system configuration files", "product_ids": [ "1", "2", "3", "4" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V16 Update 7 or later version", "product_ids": [ "2" ] }, { "category": "vendor_fix", "details": "Update to V17 Update 6 or later version", "product_ids": [ "3" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 1 or later version", "product_ids": [ "4" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4" ] } ], "title": "CVE-2023-26293" } ] }
ssa-116924
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "TIA Portal contains a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-116924.html" }, { "category": "self", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-116924.json" } ], "title": "SSA-116924: Path Traversal Vulnerability in TIA Portal", "tracking": { "current_release_date": "2024-08-13T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-116924", "initial_release_date": "2023-04-11T00:00:00Z", "revision_history": [ { "date": "2023-04-11T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2023-05-09T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added fix for Totally Integrated Automation Portal (TIA Portal) V17" }, { "date": "2024-08-13T00:00:00Z", "legacy_version": "1.2", "number": "3", "summary": "Added fix for Totally Integrated Automation Portal (TIA Portal) V16" } ], "status": "interim", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V15", "product_id": "1" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V15" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V16 Update 7", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V16", "product_id": "2" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V16" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V17 Update 6", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V17", "product_id": "3" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V17" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V18 Update 1", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V18", "product_id": "4" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V18" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-26293", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted project files or PC system configuration files", "product_ids": [ "1", "2", "3", "4" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V16 Update 7 or later version", "product_ids": [ "2" ] }, { "category": "vendor_fix", "details": "Update to V17 Update 6 or later version", "product_ids": [ "3" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 1 or later version", "product_ids": [ "4" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4" ] } ], "title": "CVE-2023-26293" } ] }
icsa-23-103-04
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting this vulnerability to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow an attacker to achieve arbitrary code execution. ", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-116924.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-103-04 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-103-04.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-103-04 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-04" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://cisa.gov/ics" }, { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-116924.html" }, { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf" }, { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-116924.txt" } ], "title": "Siemens TIA Portal", "tracking": { "current_release_date": "2023-04-18T19:27:35.039557Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-103-04", "initial_release_date": "2023-04-18T19:27:35.039557Z", "revision_history": [ { "date": "2023-04-18T19:27:35.039557Z", "legacy_version": "1", "number": "1", "summary": "CSAF Creation Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V15", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V15" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V16", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V16" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV17 Update 6", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V17", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V17" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV18 Update 1", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V18", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V18" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-26293", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-26293" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted project files or PC system configuration files", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V17 Update 6 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109784441/" }, { "category": "vendor_fix", "details": "Update to V18 Update 1 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109817218/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2023-26293" } ] }
ICSA-23-103-08
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting this vulnerability to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of the vulnerability could allow an attacker to retrieve sensitive information. ", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-116924.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-103-08 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-103-08.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-103-08 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-08" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://cisa.gov/ics" }, { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-116924.html" }, { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf" }, { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-116924.txt" } ], "title": "Siemens Mendix Forgot Password Module", "tracking": { "current_release_date": "2023-04-18T19:27:35.031502Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-103-08", "initial_release_date": "2023-04-18T19:27:35.031502Z", "revision_history": [ { "date": "2023-04-18T19:27:35.031502Z", "legacy_version": "1", "number": "1", "summary": "CSAF Creation Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V15", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V15" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V16", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V16" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV17 Update 6", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V17", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V17" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV18 Update 1", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V18", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V18" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-26293", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted project files or PC system configuration files", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V17 Update 6 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109784441/" }, { "category": "vendor_fix", "details": "Update to V18 Update 1 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109817218/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2023-26293" } ] }
icsa-23-103-08
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting this vulnerability to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of the vulnerability could allow an attacker to retrieve sensitive information. ", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-116924.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-103-08 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-103-08.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-103-08 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-08" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://cisa.gov/ics" }, { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-116924.html" }, { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf" }, { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-116924.txt" } ], "title": "Siemens Mendix Forgot Password Module", "tracking": { "current_release_date": "2023-04-18T19:27:35.031502Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-103-08", "initial_release_date": "2023-04-18T19:27:35.031502Z", "revision_history": [ { "date": "2023-04-18T19:27:35.031502Z", "legacy_version": "1", "number": "1", "summary": "CSAF Creation Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V15", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V15" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V16", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V16" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV17 Update 6", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V17", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V17" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV18 Update 1", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V18", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V18" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-26293", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted project files or PC system configuration files", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V17 Update 6 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109784441/" }, { "category": "vendor_fix", "details": "Update to V18 Update 1 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109817218/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2023-26293" } ] }
ICSA-23-103-04
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting this vulnerability to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow an attacker to achieve arbitrary code execution. ", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-116924.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-103-04 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-103-04.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-103-04 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-04" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://cisa.gov/ics" }, { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-116924.html" }, { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf" }, { "category": "external", "summary": "SSA-116924: Path Traversal Vulnerability in TIA Portal - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-116924.txt" } ], "title": "Siemens TIA Portal", "tracking": { "current_release_date": "2023-04-18T19:27:35.039557Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-103-04", "initial_release_date": "2023-04-18T19:27:35.039557Z", "revision_history": [ { "date": "2023-04-18T19:27:35.039557Z", "legacy_version": "1", "number": "1", "summary": "CSAF Creation Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V15", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V15" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V16", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V16" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV17 Update 6", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V17", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V17" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV18 Update 1", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V18", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V18" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-26293", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-26293" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L" } ], "remediations": [ { "category": "mitigation", "details": "Do not open untrusted project files or PC system configuration files", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V17 Update 6 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109784441/" }, { "category": "vendor_fix", "details": "Update to V18 Update 1 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109817218/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2023-26293" } ] }
var-202304-0844
Vulnerability from variot
A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions < V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution. Siemens' tia portal There is an input validation vulnerability in.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0844", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "tia portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15" }, { "model": "tia portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "18" }, { "model": "tia portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "tia portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "17" }, { "model": "tia portal", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "17" }, { "model": "tia portal", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "tia portal", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "18" }, { "model": "tia portal", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "tia portal", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "16" }, { "model": "tia portal", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "15" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006565" }, { "db": "NVD", "id": "CVE-2023-26293" } ] }, "cve": "CVE-2023-26293", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "productcert@siemens.com", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2023-26293", "impactScore": 5.5, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2023-26293", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "OTHER", "availabilityImpact": "Low", "baseScore": 7.3, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2023-006565", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L", "version": "3.0" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-26293", "trust": 1.0, "value": "HIGH" }, { "author": "nvd@nist.gov", "id": "CVE-2023-26293", "trust": 1.0, "value": "HIGH" }, { "author": "OTHER", "id": "JVNDB-2023-006565", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202304-722", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006565" }, { "db": "CNNVD", "id": "CNNVD-202304-722" }, { "db": "NVD", "id": "CVE-2023-26293" }, { "db": "NVD", "id": "CVE-2023-26293" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions \u003c V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution. Siemens\u0027 tia portal There is an input validation vulnerability in.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-26293" }, { "db": "JVNDB", "id": "JVNDB-2023-006565" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-26293", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-116924", "trust": 2.4 }, { "db": "ICS CERT", "id": "ICSA-23-103-04", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU94715153", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-006565", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-722", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006565" }, { "db": "CNNVD", "id": "CNNVD-202304-722" }, { "db": "NVD", "id": "CVE-2023-26293" } ] }, "id": "VAR-202304-0844", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 1.0 }, "last_update_date": "2024-08-14T12:11:50.760000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens TIA Portal Enter the fix for the verification error vulnerability", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=236715" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-722" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-20", "trust": 1.0 }, { "problemtype": "CWE-22", "trust": 1.0 }, { "problemtype": "Inappropriate input confirmation (CWE-20) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006565" }, { "db": "NVD", "id": "CVE-2023-26293" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-116924.html" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu94715153/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-26293" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-04" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-26293/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006565" }, { "db": "CNNVD", "id": "CNNVD-202304-722" }, { "db": "NVD", "id": "CVE-2023-26293" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-006565" }, { "db": "CNNVD", "id": "CNNVD-202304-722" }, { "db": "NVD", "id": "CVE-2023-26293" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-11-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006565" }, { "date": "2023-04-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-722" }, { "date": "2023-04-11T10:15:18.157000", "db": "NVD", "id": "CVE-2023-26293" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-11-15T05:44:00", "db": "JVNDB", "id": "JVNDB-2023-006565" }, { "date": "2023-05-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-722" }, { "date": "2024-08-13T08:15:05.880000", "db": "NVD", "id": "CVE-2023-26293" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-722" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens\u0027 \u00a0tia\u00a0portal\u00a0 Input verification vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006565" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "input validation error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-722" } ], "trust": 0.6 } }
ghsa-pfr5-cpm3-g35v
Vulnerability from github
A vulnerability has been identified in TIA Portal V15 (All versions), TIA Portal V16 (All versions), TIA Portal V17 (All versions), TIA Portal V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.
{ "affected": [], "aliases": [ "CVE-2023-26293" ], "database_specific": { "cwe_ids": [ "CWE-20", "CWE-22" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2023-04-11T10:15:00Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in TIA Portal V15 (All versions), TIA Portal V16 (All versions), TIA Portal V17 (All versions), TIA Portal V18 (All versions \u003c V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.", "id": "GHSA-pfr5-cpm3-g35v", "modified": "2024-08-13T09:30:50Z", "published": "2023-04-11T12:30:26Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-26293" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-116924.html" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L", "type": "CVSS_V3" } ] }
wid-sec-w-2023-0909
Vulnerability from csaf_certbund
Notes
{ "document": { "aggregate_severity": { "text": "mittel" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "TIA-Portal ist ein Automatisierungsframework f\u00fcr Steuerungen und andere Automatisierungsger\u00e4te der SIMATIC-Serie.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein entfernter, anonymer Angreifer kann eine Schwachstelle in Siemens TIA Portal ausnutzen, um beliebigen Programmcode auszuf\u00fchren.", "title": "Angriff" }, { "category": "general", "text": "- Appliance", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2023-0909 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2023/wid-sec-w-2023-0909.json" }, { "category": "self", "summary": "WID-SEC-2023-0909 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2023-0909" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-04-10", "url": "https://cert-portal.siemens.com/productcert/html/ssa-116924.html" } ], "source_lang": "en-US", "title": "Siemens TIA Portal: Schwachstelle erm\u00f6glicht Codeausf\u00fchrung", "tracking": { "current_release_date": "2023-04-10T22:00:00.000+00:00", "generator": { "date": "2024-08-15T17:48:25.623+00:00", "engine": { "name": "BSI-WID", "version": "1.3.5" } }, "id": "WID-SEC-W-2023-0909", "initial_release_date": "2023-04-10T22:00:00.000+00:00", "revision_history": [ { "date": "2023-04-10T22:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_name", "name": "Siemens TIA Portal \u003c V18 Update 1", "product": { "name": "Siemens TIA Portal \u003c V18 Update 1", "product_id": "T027137", "product_identification_helper": { "cpe": "cpe:/a:siemens:tia_portal:v18_update_1" } } }, { "category": "product_name", "name": "Siemens TIA Portal V15", "product": { "name": "Siemens TIA Portal V15", "product_id": "T027139", "product_identification_helper": { "cpe": "cpe:/a:siemens:tia_portal:v15" } } }, { "category": "product_name", "name": "Siemens TIA Portal V16", "product": { "name": "Siemens TIA Portal V16", "product_id": "T027140", "product_identification_helper": { "cpe": "cpe:/a:siemens:tia_portal:v16" } } }, { "category": "product_name", "name": "Siemens TIA Portal V17", "product": { "name": "Siemens TIA Portal V17", "product_id": "T027141", "product_identification_helper": { "cpe": "cpe:/a:siemens:tia_portal:v17" } } } ], "category": "product_name", "name": "TIA Portal" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-26293", "notes": [ { "category": "description", "text": "Es existiert eine Schwachstelle in Siemens TIA Portal. Es besteht eine Anf\u00e4lligkeit f\u00fcr einen Path-Traversal-Angriff aufgrund unsachgem\u00e4\u00dfer Eingabevalidierungen. Ein entfernter, anonymer Angreifer kann diese Schwachstelle ausnutzen, um beliebigen Programmcode auszuf\u00fchren. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich." } ], "product_status": { "known_affected": [ "T027140", "T027141", "T027139" ] }, "release_date": "2023-04-10T22:00:00.000+00:00", "title": "CVE-2023-26293" } ] }
WID-SEC-W-2023-0909
Vulnerability from csaf_certbund
Notes
{ "document": { "aggregate_severity": { "text": "mittel" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "TIA-Portal ist ein Automatisierungsframework f\u00fcr Steuerungen und andere Automatisierungsger\u00e4te der SIMATIC-Serie.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein entfernter, anonymer Angreifer kann eine Schwachstelle in Siemens TIA Portal ausnutzen, um beliebigen Programmcode auszuf\u00fchren.", "title": "Angriff" }, { "category": "general", "text": "- Appliance", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2023-0909 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2023/wid-sec-w-2023-0909.json" }, { "category": "self", "summary": "WID-SEC-2023-0909 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2023-0909" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-04-10", "url": "https://cert-portal.siemens.com/productcert/html/ssa-116924.html" } ], "source_lang": "en-US", "title": "Siemens TIA Portal: Schwachstelle erm\u00f6glicht Codeausf\u00fchrung", "tracking": { "current_release_date": "2023-04-10T22:00:00.000+00:00", "generator": { "date": "2024-08-15T17:48:25.623+00:00", "engine": { "name": "BSI-WID", "version": "1.3.5" } }, "id": "WID-SEC-W-2023-0909", "initial_release_date": "2023-04-10T22:00:00.000+00:00", "revision_history": [ { "date": "2023-04-10T22:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_name", "name": "Siemens TIA Portal \u003c V18 Update 1", "product": { "name": "Siemens TIA Portal \u003c V18 Update 1", "product_id": "T027137", "product_identification_helper": { "cpe": "cpe:/a:siemens:tia_portal:v18_update_1" } } }, { "category": "product_name", "name": "Siemens TIA Portal V15", "product": { "name": "Siemens TIA Portal V15", "product_id": "T027139", "product_identification_helper": { "cpe": "cpe:/a:siemens:tia_portal:v15" } } }, { "category": "product_name", "name": "Siemens TIA Portal V16", "product": { "name": "Siemens TIA Portal V16", "product_id": "T027140", "product_identification_helper": { "cpe": "cpe:/a:siemens:tia_portal:v16" } } }, { "category": "product_name", "name": "Siemens TIA Portal V17", "product": { "name": "Siemens TIA Portal V17", "product_id": "T027141", "product_identification_helper": { "cpe": "cpe:/a:siemens:tia_portal:v17" } } } ], "category": "product_name", "name": "TIA Portal" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-26293", "notes": [ { "category": "description", "text": "Es existiert eine Schwachstelle in Siemens TIA Portal. Es besteht eine Anf\u00e4lligkeit f\u00fcr einen Path-Traversal-Angriff aufgrund unsachgem\u00e4\u00dfer Eingabevalidierungen. Ein entfernter, anonymer Angreifer kann diese Schwachstelle ausnutzen, um beliebigen Programmcode auszuf\u00fchren. Zur erfolgreichen Ausnutzung ist eine Benutzeraktion erforderlich." } ], "product_status": { "known_affected": [ "T027140", "T027141", "T027139" ] }, "release_date": "2023-04-10T22:00:00.000+00:00", "title": "CVE-2023-26293" } ] }
fkie_cve-2023-26293
Vulnerability from fkie_nvd
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
siemens | tia_portal | 15 | |
siemens | tia_portal | 16 | |
siemens | tia_portal | 17 | |
siemens | tia_portal | 17 | |
siemens | tia_portal | 17 | |
siemens | tia_portal | 17 | |
siemens | tia_portal | 17 | |
siemens | tia_portal | 17 | |
siemens | tia_portal | 18 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:tia_portal:15:*:*:*:*:*:*:*", "matchCriteriaId": "FB7DAF87-8685-402D-B8AF-30E3DBC8B37C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:16:*:*:*:*:*:*:*", "matchCriteriaId": "85B6CBCC-CBF6-45F3-A475-FF154208E58C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:17:-:*:*:*:*:*:*", "matchCriteriaId": "85EDE398-4E18-4F39-9F00-66E9EDB17AD7", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:17:update1:*:*:*:*:*:*", "matchCriteriaId": "7C4DFB46-947A-4156-B760-5754D3A502B7", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:17:update2:*:*:*:*:*:*", "matchCriteriaId": "4A46017D-5AF4-4063-92E8-83228CCDEB45", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:17:update3:*:*:*:*:*:*", "matchCriteriaId": "903EA460-9F1F-4BB1-AAF4-9B17A864892A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:17:update4:*:*:*:*:*:*", "matchCriteriaId": "D63A193B-18EB-4399-8528-BC58C88CB19C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:17:update5:*:*:*:*:*:*", "matchCriteriaId": "931BB5EB-D243-4E06-844B-567B899905F2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:18:-:*:*:*:*:*:*", "matchCriteriaId": "50C20804-6D7D-49AB-8789-625CA57C077B", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions \u003c V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution." } ], "id": "CVE-2023-26293", "lastModified": "2024-11-21T07:51:04.510", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.5, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-04-11T10:15:18.157", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-116924.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
gsd-2023-26293
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2023-26293", "id": "GSD-2023-26293" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-26293" ], "details": "A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.", "id": "GSD-2023-26293", "modified": "2023-12-13T01:20:53.814715Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2023-26293", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Totally Integrated Automation Portal (TIA Portal) V15", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions" } ] } }, { "product_name": "Totally Integrated Automation Portal (TIA Portal) V16", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions" } ] } }, { "product_name": "Totally Integrated Automation Portal (TIA Portal) V17", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V17 Update 6" } ] } }, { "product_name": "Totally Integrated Automation Portal (TIA Portal) V18", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V18 Update 1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution." } ] }, "impact": { "cvss": [ { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-20", "lang": "eng", "value": "CWE-20: Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf" } ] } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:tia_portal:15:*:*:*:*:*:*:*", "matchCriteriaId": "FB7DAF87-8685-402D-B8AF-30E3DBC8B37C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:16:*:*:*:*:*:*:*", "matchCriteriaId": "85B6CBCC-CBF6-45F3-A475-FF154208E58C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:17:-:*:*:*:*:*:*", "matchCriteriaId": "85EDE398-4E18-4F39-9F00-66E9EDB17AD7", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:17:update1:*:*:*:*:*:*", "matchCriteriaId": "7C4DFB46-947A-4156-B760-5754D3A502B7", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:17:update2:*:*:*:*:*:*", "matchCriteriaId": "4A46017D-5AF4-4063-92E8-83228CCDEB45", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:17:update3:*:*:*:*:*:*", "matchCriteriaId": "903EA460-9F1F-4BB1-AAF4-9B17A864892A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:17:update4:*:*:*:*:*:*", "matchCriteriaId": "D63A193B-18EB-4399-8528-BC58C88CB19C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:17:update5:*:*:*:*:*:*", "matchCriteriaId": "931BB5EB-D243-4E06-844B-567B899905F2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_portal:18:-:*:*:*:*:*:*", "matchCriteriaId": "50C20804-6D7D-49AB-8789-625CA57C077B", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution." } ], "id": "CVE-2023-26293", "lastModified": "2024-02-01T15:19:36.830", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.5, "source": "productcert@siemens.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-04-11T10:15:18.157", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116924.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] } } } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.