Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2022-36324 (GCVE-0-2022-36324)
Vulnerability from cvelistv5 – Published: 2022-08-10 11:18 – Updated: 2026-04-14 08:35- CWE-770 - Allocation of Resources Without Limits or Throttling
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | RUGGEDCOM RM1224 LTE(4G) NAM |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE M804PB |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE M812-1 ADSL-Router |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE M812-1 ADSL-Router |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE M816-1 ADSL-Router |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE M816-1 ADSL-Router |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE M826-2 SHDSL-Router |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE M874-2 |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE M874-3 |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE M876-3 |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE M876-3 (ROK) |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE M876-4 (EU) |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE M876-4 (NAM) |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE MUM853-1 (EU) |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (EU) |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE MUM856-1 (RoW) |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE S615 LAN-Router |
Affected:
0 , < V7.1.2
(custom)
|
|
| Siemens | SCALANCE SC622-2C |
Affected:
0 , < V2.3.1
(custom)
|
|
| Siemens | SCALANCE SC626-2C |
Affected:
0 , < V2.3.1
(custom)
|
|
| Siemens | SCALANCE SC632-2C |
Affected:
0 , < V2.3.1
(custom)
|
|
| Siemens | SCALANCE SC636-2C |
Affected:
0 , < V2.3.1
(custom)
|
|
| Siemens | SCALANCE SC642-2C |
Affected:
0 , < V2.3.1
(custom)
|
|
| Siemens | SCALANCE SC646-2C |
Affected:
0 , < V2.3.1
(custom)
|
|
| Siemens | SCALANCE W1748-1 M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1748-1 M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-1 M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-2 EEC M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-2 M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W1788-2IA M12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SCALANCE W721-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W721-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W721-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W721-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W722-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W722-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W722-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W722-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W722-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W722-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W734-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W734-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W734-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W734-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W734-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W734-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W734-1 RJ45 (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W734-1 RJ45 (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W738-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W738-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W738-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W738-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W748-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W748-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W748-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W748-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W748-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W748-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W748-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W748-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W761-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W761-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W761-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W761-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W774-1 RJ45 (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 EEC (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W778-1 M12 EEC (USA) |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 SFP |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 SFP |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 SFP |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2 SFP |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2IA RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2IA RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2IA RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W786-2IA RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-1 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-1 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 M12 EEC |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE W788-2 RJ45 |
Affected:
0 , < V6.6.0
(custom)
|
|
| Siemens | SCALANCE WAM763-1 |
Affected:
0 , < V2.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 |
Affected:
0 , < V2.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 (US) |
Affected:
0 , < V2.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 EEC |
Affected:
0 , < V2.0.0
(custom)
|
|
| Siemens | SCALANCE WAM766-1 EEC (US) |
Affected:
0 , < V2.0.0
(custom)
|
|
| Siemens | SCALANCE WUM763-1 |
Affected:
0 , < V2.0.0
(custom)
|
|
| Siemens | SCALANCE WUM763-1 |
Affected:
0 , < V2.0.0
(custom)
|
|
| Siemens | SCALANCE WUM766-1 |
Affected:
0 , < V2.0.0
(custom)
|
|
| Siemens | SCALANCE WUM766-1 (USA) |
Affected:
0 , < V2.0.0
(custom)
|
|
| Siemens | SCALANCE XB205-3 (SC, PN) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB205-3 (ST, E/IP) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB205-3 (ST, E/IP) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB205-3 (ST, PN) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB205-3LD (SC, E/IP) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB205-3LD (SC, PN) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB208 (E/IP) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB208 (PN) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB213-3 (SC, E/IP) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB213-3 (SC, PN) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB213-3 (ST, E/IP) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB213-3 (ST, PN) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB213-3LD (SC, E/IP) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB213-3LD (SC, PN) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB216 (E/IP) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XB216 (PN) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC206-2 (SC) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC206-2 (ST/BFOC) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC206-2G PoE |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC206-2G PoE (54 V DC) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC206-2G PoE EEC (54 V DC) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP EEC |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP G |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP G (EIP DEF.) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC206-2SFP G EEC |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC208 |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC208EEC |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC208G |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC208G (EIP def.) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC208G EEC |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC208G PoE |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC208G PoE (54 V DC) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC216 |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC216-3G PoE |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC216-3G PoE (54 V DC) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC216-4C |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC216-4C G |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC216-4C G (EIP Def.) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC216-4C G EEC |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC216EEC |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC224 |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC224-4C G |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC224-4C G (EIP Def.) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XC224-4C G EEC |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XF204 |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XF204 DNA |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XF204-2BA |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XF204-2BA DNA |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XM408-4C |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XM408-4C (L3 int.) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XM408-8C |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XM408-8C (L3 int.) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XM416-4C |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XM416-4C (L3 int.) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XP208 |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XP208 (Ethernet/IP) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XP208EEC |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XP208PoE EEC |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XP216 |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XP216 (Ethernet/IP) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XP216EEC |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XP216POE EEC |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XR324WG (24 x FE, AC 230V) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XR324WG (24 X FE, DC 24V) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XR326-2C PoE WG |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XR326-2C PoE WG (without UL) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (28xGE, AC 230V) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XR328-4C WG (28xGE, DC 24V) |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 1x230V |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 1x230V (L3 int.) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 24V |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 24V (L3 int.) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 2x230V |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR524-8C, 2x230V (L3 int.) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 1x230V |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 1x230V (L3 int.) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 24V |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 24V (L3 int.) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 2x230V |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR526-8C, 2x230V (L3 int.) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR528-6M |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR528-6M (2HR2, L3 int.) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR528-6M (2HR2) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR528-6M (L3 int.) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR552-12M |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR552-12M (2HR2, L3 int.) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR552-12M (2HR2) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SCALANCE XR552-12M (2HR2) |
Affected:
0 , < V6.6
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC206-2 |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC206-2SFP |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC208 |
Affected:
0 , < V4.4
(custom)
|
|
| Siemens | SIPLUS NET SCALANCE XC216-4C |
Affected:
0 , < V4.4
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:00:04.354Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-36324",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:12:22.854913Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:51:04.290Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) EU",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 LTE(4G) NAM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM853-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (EU)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE MUM856-1 (RoW)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC622-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC626-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC632-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC636-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC642-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE SC646-2C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 EEC M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W1788-2IA M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W721-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W722-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W734-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W738-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W748-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W761-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W774-1 RJ45 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W778-1 M12 EEC (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2 SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W786-2IA RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-1 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 M12 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W788-2 RJ45",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WAM766-1 EEC (US)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM763-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE WUM766-1 (USA)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB205-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB208 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3 (ST, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB213-3LD (SC, PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (E/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB216 (PN)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2 (ST/BFOC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G (EIP DEF.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC206-2SFP G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G (EIP def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC208G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-3G PoE (54 V DC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G (EIP Def.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC224-4C G EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204 DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA DNA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM408-8C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM416-4C (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP208PoE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216 (Ethernet/IP)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP216POE EEC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 x FE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324WG (24 X FE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR326-2C PoE WG (without UL)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 24V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR528-6M (L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2, L3 int.)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR552-12M (2HR2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC206-2SFP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC208",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE XC216-4C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770: Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-14T08:35:27.763Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-019200.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-36324",
"datePublished": "2022-08-10T11:18:39.000Z",
"dateReserved": "2022-07-20T00:00:00.000Z",
"dateUpdated": "2026-04-14T08:35:27.763Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-36324",
"date": "2026-05-12",
"epss": "0.01536",
"percentile": "0.81484"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A43ECBDD-F831-4364-8869-C696D1AC531A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DFB9921A-5204-40A3-88AB-B7755F5C6875\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6EF65A06-2222-47D2-83B5-4C61E6D8731E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E917CBBB-EF41-4113-B0CA-EB91889235E7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_w700_ieee_802.11ax_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"23DDDAEC-C0B4-4E14-9840-101B6F24DBE5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_w700_ieee_802.11ax:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"09908B6A-6655-42F0-A20B-79FFBF81937A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F05D6764-79B4-4787-B2D2-E685910453C3\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"880644DA-9280-4498-AD72-5CBD59CC8142\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_w700_ieee_802.11ac_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8D7CF655-D174-4CE8-A2AC-C14967A8283B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_w700_ieee_802.11ac:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C93984BD-70E6-496C-BA20-18464B0E84B3\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E673B450-C436-49F3-B2F3-872B704FE075\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8CB0BE85-4A96-45EB-9EAA-A2D9E5D45508\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B9F9F101-6042-4D11-98CE-16A996023B38\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D9E6A2AB-7F15-4ABB-B00A-F5667B615ABE\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"18DC9125-FC41-4BAB-9638-C42DEF40235B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"713ADE75-1915-4DBB-9FC3-59E9A03AB5A8\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5C19D54A-8070-4EC6-9B30-B1B04A8BDABD\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D0113244-9647-4E95-B1E4-DBD26ADD3786\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1FF67A06-D93B-4E4E-A639-29E0E49654FE\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"692B60D5-696D-4680-BB38-3C0EC0F2D034\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D83C08F3-C6F7-46D1-B3F6-0173F9B7E983\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C08F92C8-0A5D-470E-8CFC-F622C3014336\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7719E194-EE3D-4CE8-8C85-CF0D82A553AA\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1C93B717-35A4-4824-9B85-DB046E38DA33\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"49C5CBD8-9799-4EBA-8297-EAE04F43DDD5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4F02CFE9-6058-4B0D-9FD5-6C84ED4A3EAD\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"39310380-7D17-46C5-B91A-DFDF602D56A5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C4EA7C54-4200-4E33-B2EA-0F82AA3ECD9D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0C21EC27-F0A8-4DCA-88AD-92D07477B5AD\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4B9CA045-5DB1-422C-ABE2-AC89F5A27847\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CC286693-55D6-4949-8164-262EB6C022C9\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"81AD4EB0-A125-4E4B-9348-AA6E670061B2\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BC7B235D-0141-46E5-9057-2203555AE58A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\\\(e\\\\/ip\\\\)_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"82708B62-47F9-4909-A52C-D96BC3AA567D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\\\(e\\\\/ip\\\\):-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CB6B6ED1-7057-4240-B1C9-660173BF1A6A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"49EBEDA9-A826-45DD-A5BB-D5B55FB47B60\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6F7D1CCD-4DFD-4037-9BDC-65466D639456\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"822CB559-BAFC-4674-A64B-BDCF1AAFDD0E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"316A0742-A32F-453E-922A-F084D9BEAA19\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B6550B2D-4B8E-414C-B4CB-7B12D6D4EA4A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"62C9A709-2AB4-4836-B925-988D78AEB278\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8E922B78-7951-4115-8985-D824F6DDE41B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc208g_\\\\(e\\\\/ip\\\\)_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"17E1B7ED-A272-43C6-9CA5-4CF370F8ED1C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc208g_\\\\(e\\\\/ip\\\\):-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"62852B4B-AF5A-4967-AFC2-14CEC2F6972C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1ABF1FC1-2FB5-42D8-867C-0B93AB67C096\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9CCF0CEF-2E48-472E-9BDE-6E63F4CEA467\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"429647B3-1C26-42EF-94DC-B9630AA627CD\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"585424EB-F9AB-45FB-B5C5-78FE45E3341A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D2F04D78-74F0-4471-9AF6-54EA822F1992\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4ABC0D8D-4F32-487F-835C-DADAB647EC21\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"00C80C92-FC92-4B96-8B80-6F7E0B07EBAD\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7668BC0B-A47A-4E05-9933-51CD43F3B7BA\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AA3B23C3-8880-4640-A6B2-EA870A85AAFE\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"78645734-50C1-4331-9FC4-AC8A8679B6AF\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc216-4c_g_\\\\(e\\\\/ip\\\\)_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B2765D0D-9A77-45E5-9F58-BF877E6F94B7\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc216-4c_g_\\\\(e\\\\/ip\\\\):-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"22B8B758-9781-474E-93C3-17DDDF263CC2\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"09F27730-5DB8-4736-B6ED-A46C3888F48D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"323CEAEA-8122-43A5-BB87-97C7133FF510\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A5A04F9F-133C-4C02-BA65-CABA47E1F329\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6BE498F8-A9D8-4A92-90CE-21BA30234947\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2EA0205D-A280-4903-927A-AC4FEC051E2A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"39AB9EB3-0F05-41C2-A32F-27B6D0C9C039\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CFF36832-3023-4AEA-800E-ED4D87271E3A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E7806CF9-4DA5-4090-84BD-D098C5FB1178\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc224-4c_g_\\\\(e\\\\/ip\\\\)_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"33C3BB4B-63C9-4770-9CC0-053A0B655ED7\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc224-4c_g_\\\\(e\\\\/ip\\\\):-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EE4E3630-DB15-46EA-B320-E4E457240B9F\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D9089DA8-FEF8-4927-B56A-139B67571671\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"34F19168-C521-4D67-BF88-1551F079859E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"58377C58-F660-4C17-A3CB-BFC2F28848CD\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A6C7A93D-B629-4A56-B961-5D4FD012E6E6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FAF28152-D6CA-4D20-BDF1-1EF4B7D10429\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4F316894-3BBB-4B72-8636-23868BF557AB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"99E6AFAA-B903-47BB-B0F3-7650B039C0FB\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B6BF5436-1BCB-4945-8F2D-68F766D3567F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9FC408A8-903F-43A2-9D05-65AD4482FDBB\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"813D5C37-C5CF-4B50-920A-38C9CF042966\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2AA81823-013F-4990-B62D-86C404F04BCB\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0DFCB811-4CE6-4FA9-A722-86ED0D434FD9\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B2FB222B-0414-4A1E-8BBD-6470CDB3BFF8\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"24722F13-7DA7-4CA6-A141-293DE72B15B4\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7096DBA5-95BB-44D7-B7CA-B1845C87F70E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CFE568ED-3604-428E-82E7-4027CB2DDD62\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"78562689-B494-4500-9725-B418F1EC3CAB\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"616BB0A9-47FB-4F72-8241-0ADF50E6E236\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F9102A41-5812-4014-BC07-E571E815ED49\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"04B56011-74F9-4760-A4AD-850F0CCF0B62\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"86A2A766-9046-484F-9D49-4A1F4F0F96A4\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3491A486-47F3-4B30-B613-DCC412F6EF5B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8F962FC7-0616-467F-8CCA-ADEA224B5F7B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"54BB088B-67FC-4C34-98A0-EC05B67B2396\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"24C7FB09-D247-48F0-B87C-6A478BDC0A5A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xp208_\\\\(eip\\\\)_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BF3C7B31-25AA-4D74-AB2D-5C7F1D8025C1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xp208_\\\\(eip\\\\):-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"17BD41C2-2398-4A03-9C5F-43AEF424261E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DCFA1A9B-1130-46BC-9A5F-FFBB527517FF\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2B313A4C-D3E7-4964-BA51-3401546B36C5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E5AAC31E-42DE-423E-8F43-A5600E24160F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D6E888EA-73A7-42B8-A617-621CF192F2A9\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7D5F9D33-F74A-4FFB-9327-5CE691F0C1D6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"67E4D039-5BF8-469B-A6FE-A391A6D1BDA4\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xp216_\\\\(eip\\\\)_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7E0BC528-5B72-48AB-A70A-B116770A8587\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xp216_\\\\(eip\\\\):-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"33D044BD-12AD-42C9-B01C-957BEC6C6790\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"18D7E470-D872-4C37-8669-B66328F173D6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"12512EC4-FB7D-420F-9A8A-547562BE1B49\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F51CE85F-16D1-4E49-83C7-70C90233E294\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B357AD42-1806-4BE5-B76D-F798E475F659\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"889CF2C0-EE6C-447F-85F1-005730EAD232\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr-300eec_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"17115730-97BF-473F-A4A7-03D5AE0F1A6D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6FF41E9F-4627-49EE-BCF1-08B5AADE964A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr-300poe_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"18537338-DF5C-4F7A-995E-7F953B380657\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CC118867-1A6C-4C3B-AD75-5D24551DB0BC\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"64A47C63-7150-4F8D-BFD9-2F5C2761DBDF\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0AC751E0-FC87-4DEB-85E8-C3E028B76482\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"36C9AE74-4683-4ED0-A605-3A6B065C230E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EB09860F-9DC8-476B-9AF7-6FFE57101D6C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4356417E-B4CB-45B0-B395-CE9D423FAB44\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1E6AB4BE-D669-4A95-8F8A-F2DA146D5FB1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6F952542-6B79-4681-A236-15C188AAEB1E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1F4B8E2B-DEFF-4F1C-B5A4-0C4671C605C1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"664D9C76-BC13-4874-939C-A8211DA33903\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9F4DE2B7-1AB3-4BA5-B261-926B774B01DD\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4834A67B-7B0B-4F88-BBFB-25667FD68EC5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr324wg_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"82D18854-D803-40C6-BB14-A28594C37CDB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E767C461-8FA6-4700-98CB-734AFD309140\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr326-2c_poe_wg_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4B7EC611-120E-4002-BF1E-4B45E431B7FC\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr326-2c_poe_wg:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CBD19EFB-12D2-4401-B87A-91873528E474\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AFA83BBC-C6F3-4F98-A92B-2611EACBC093\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A5B7DEDC-66BD-4701-BBDD-16273263ADC9\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FC8637DA-CA1E-46C6-AD1D-4F90B2A0BB35\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"080E722F-FCD4-4967-86EE-151ADC5702E7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BA8C39A2-1989-49ED-91FC-7BCE7002F250\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7DEEA300-16C3-4FEE-88A8-674DE2AEEC95\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BA970560-8AE2-49B1-BCD0-E7913DEA50ED\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AC7CB42C-666C-4DFD-B3CB-DD9509363E94\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A1509C8A-89FC-445D-BB22-BF9A811E853B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8709D27F-90B9-4AF8-8784-E974CE859518\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"756A07F8-4F9F-4A76-942E-82CB92216943\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"554455C1-19FF-4F71-BC36-13DDE7FE0087\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"67661569-6233-4C74-9C72-88BD14B257FE\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"10F66ADC-91EC-4ED0-B768-03F94241B300\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0921AD23-44BA-4F5C-9DC8-A5F90753C977\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F41F6AE6-0E43-4D12-B379-FCF3A2A104DB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FDE5E54D-FFED-4C2C-B89D-E085E61D44E4\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B0630BF0-8EFD-425A-A371-E1B0E5074D4D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3E048C4A-A414-4C87-A865-4D4218AE32EE\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DEAA4C6F-F234-4895-9D0D-B89E3F07F038\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr528-6m_2hr2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"03DFEC43-5E84-460A-A50E-6BF378E83A70\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_l3_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"64CCA458-1F7F-44ED-ACD5-E9355B112194\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr528-6m_2hr2_l3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FD9EACF0-ECE5-40DD-8280-41707A637E9E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr528-6m_l3_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7B7870B9-F1CF-4503-A64C-6258FFB9D78D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr528-6m_l3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"81355370-BE69-434F-ABAC-8611F9909E46\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7319A333-EAA2-4ED2-A814-1AAEDFAC4E04\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AB16A0BE-5AF3-4168-B755-D023E497A35F\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B490BBD4-458F-4077-8404-9208499226E7\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"09743616-31C9-4E47-8A4A-B15D76204BE7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr552-12m_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"87B35693-9D07-4507-8070-43B8F756F772\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4A806691-3F4B-46AA-9718-2F6BF0FD3D7A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B05DE63D-186B-46CC-B3CE-66923F290B6B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr552-12m_2hr2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C97B2B53-F40E-4FB1-B3BA-5D0E0F8501F0\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_l3_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EF61A53B-E4AD-4379-B053-1A25FDF65BD0\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_xr552-12m_2hr2_l3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BA9921B1-38FD-4404-9986-3023C577FE5C\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.\"}, {\"lang\": \"es\", \"value\": \"Los dispositivos afectados no manejan adecuadamente la renegociaci\\u00f3n de los par\\u00e1metros SSL/TLS. Esto podr\\u00eda permitir a un atacante remoto no autenticado eludir la prevenci\\u00f3n de fuerza bruta de TCP y provocar una condici\\u00f3n de denegaci\\u00f3n de servicio mientras dure el ataque\"}]",
"id": "CVE-2022-36324",
"lastModified": "2024-11-21T07:12:47.307",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
"published": "2022-08-10T12:15:12.930",
"references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-770\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-770\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-36324\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-08-10T12:15:12.930\",\"lastModified\":\"2026-04-14T09:16:30.903\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.\"},{\"lang\":\"es\",\"value\":\"Los dispositivos afectados no manejan adecuadamente la renegociaci\u00f3n de los par\u00e1metros SSL/TLS. Esto podr\u00eda permitir a un atacante remoto no autenticado eludir la prevenci\u00f3n de fuerza bruta de TCP y provocar una condici\u00f3n de denegaci\u00f3n de servicio mientras dure el ataque\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-770\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-770\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A43ECBDD-F831-4364-8869-C696D1AC531A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DFB9921A-5204-40A3-88AB-B7755F5C6875\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6EF65A06-2222-47D2-83B5-4C61E6D8731E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E917CBBB-EF41-4113-B0CA-EB91889235E7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_w700_ieee_802.11ax_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"23DDDAEC-C0B4-4E14-9840-101B6F24DBE5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_w700_ieee_802.11ax:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"09908B6A-6655-42F0-A20B-79FFBF81937A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F05D6764-79B4-4787-B2D2-E685910453C3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"880644DA-9280-4498-AD72-5CBD59CC8142\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_w700_ieee_802.11ac_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8D7CF655-D174-4CE8-A2AC-C14967A8283B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_w700_ieee_802.11ac:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C93984BD-70E6-496C-BA20-18464B0E84B3\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E673B450-C436-49F3-B2F3-872B704FE075\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8CB0BE85-4A96-45EB-9EAA-A2D9E5D45508\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B9F9F101-6042-4D11-98CE-16A996023B38\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D9E6A2AB-7F15-4ABB-B00A-F5667B615ABE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18DC9125-FC41-4BAB-9638-C42DEF40235B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"713ADE75-1915-4DBB-9FC3-59E9A03AB5A8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5C19D54A-8070-4EC6-9B30-B1B04A8BDABD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D0113244-9647-4E95-B1E4-DBD26ADD3786\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1FF67A06-D93B-4E4E-A639-29E0E49654FE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"692B60D5-696D-4680-BB38-3C0EC0F2D034\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D83C08F3-C6F7-46D1-B3F6-0173F9B7E983\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C08F92C8-0A5D-470E-8CFC-F622C3014336\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7719E194-EE3D-4CE8-8C85-CF0D82A553AA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1C93B717-35A4-4824-9B85-DB046E38DA33\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"49C5CBD8-9799-4EBA-8297-EAE04F43DDD5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4F02CFE9-6058-4B0D-9FD5-6C84ED4A3EAD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"39310380-7D17-46C5-B91A-DFDF602D56A5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C4EA7C54-4200-4E33-B2EA-0F82AA3ECD9D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0C21EC27-F0A8-4DCA-88AD-92D07477B5AD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4B9CA045-5DB1-422C-ABE2-AC89F5A27847\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC286693-55D6-4949-8164-262EB6C022C9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"81AD4EB0-A125-4E4B-9348-AA6E670061B2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BC7B235D-0141-46E5-9057-2203555AE58A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\\\(e\\\\/ip\\\\)_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"82708B62-47F9-4909-A52C-D96BC3AA567D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\\\(e\\\\/ip\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CB6B6ED1-7057-4240-B1C9-660173BF1A6A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"49EBEDA9-A826-45DD-A5BB-D5B55FB47B60\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F7D1CCD-4DFD-4037-9BDC-65466D639456\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"822CB559-BAFC-4674-A64B-BDCF1AAFDD0E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"316A0742-A32F-453E-922A-F084D9BEAA19\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B6550B2D-4B8E-414C-B4CB-7B12D6D4EA4A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"62C9A709-2AB4-4836-B925-988D78AEB278\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8E922B78-7951-4115-8985-D824F6DDE41B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc208g_\\\\(e\\\\/ip\\\\)_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"17E1B7ED-A272-43C6-9CA5-4CF370F8ED1C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc208g_\\\\(e\\\\/ip\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"62852B4B-AF5A-4967-AFC2-14CEC2F6972C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1ABF1FC1-2FB5-42D8-867C-0B93AB67C096\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9CCF0CEF-2E48-472E-9BDE-6E63F4CEA467\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"429647B3-1C26-42EF-94DC-B9630AA627CD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"585424EB-F9AB-45FB-B5C5-78FE45E3341A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2F04D78-74F0-4471-9AF6-54EA822F1992\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4ABC0D8D-4F32-487F-835C-DADAB647EC21\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"00C80C92-FC92-4B96-8B80-6F7E0B07EBAD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7668BC0B-A47A-4E05-9933-51CD43F3B7BA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AA3B23C3-8880-4640-A6B2-EA870A85AAFE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"78645734-50C1-4331-9FC4-AC8A8679B6AF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc216-4c_g_\\\\(e\\\\/ip\\\\)_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B2765D0D-9A77-45E5-9F58-BF877E6F94B7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc216-4c_g_\\\\(e\\\\/ip\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"22B8B758-9781-474E-93C3-17DDDF263CC2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"09F27730-5DB8-4736-B6ED-A46C3888F48D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"323CEAEA-8122-43A5-BB87-97C7133FF510\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A5A04F9F-133C-4C02-BA65-CABA47E1F329\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6BE498F8-A9D8-4A92-90CE-21BA30234947\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2EA0205D-A280-4903-927A-AC4FEC051E2A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"39AB9EB3-0F05-41C2-A32F-27B6D0C9C039\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CFF36832-3023-4AEA-800E-ED4D87271E3A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E7806CF9-4DA5-4090-84BD-D098C5FB1178\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc224-4c_g_\\\\(e\\\\/ip\\\\)_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"33C3BB4B-63C9-4770-9CC0-053A0B655ED7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc224-4c_g_\\\\(e\\\\/ip\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EE4E3630-DB15-46EA-B320-E4E457240B9F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D9089DA8-FEF8-4927-B56A-139B67571671\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"34F19168-C521-4D67-BF88-1551F079859E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"58377C58-F660-4C17-A3CB-BFC2F28848CD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A6C7A93D-B629-4A56-B961-5D4FD012E6E6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FAF28152-D6CA-4D20-BDF1-1EF4B7D10429\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4F316894-3BBB-4B72-8636-23868BF557AB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"99E6AFAA-B903-47BB-B0F3-7650B039C0FB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B6BF5436-1BCB-4945-8F2D-68F766D3567F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9FC408A8-903F-43A2-9D05-65AD4482FDBB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"813D5C37-C5CF-4B50-920A-38C9CF042966\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2AA81823-013F-4990-B62D-86C404F04BCB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0DFCB811-4CE6-4FA9-A722-86ED0D434FD9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B2FB222B-0414-4A1E-8BBD-6470CDB3BFF8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"24722F13-7DA7-4CA6-A141-293DE72B15B4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7096DBA5-95BB-44D7-B7CA-B1845C87F70E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CFE568ED-3604-428E-82E7-4027CB2DDD62\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"78562689-B494-4500-9725-B418F1EC3CAB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"616BB0A9-47FB-4F72-8241-0ADF50E6E236\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F9102A41-5812-4014-BC07-E571E815ED49\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"04B56011-74F9-4760-A4AD-850F0CCF0B62\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"86A2A766-9046-484F-9D49-4A1F4F0F96A4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3491A486-47F3-4B30-B613-DCC412F6EF5B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8F962FC7-0616-467F-8CCA-ADEA224B5F7B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"54BB088B-67FC-4C34-98A0-EC05B67B2396\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"24C7FB09-D247-48F0-B87C-6A478BDC0A5A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xp208_\\\\(eip\\\\)_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BF3C7B31-25AA-4D74-AB2D-5C7F1D8025C1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xp208_\\\\(eip\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"17BD41C2-2398-4A03-9C5F-43AEF424261E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DCFA1A9B-1130-46BC-9A5F-FFBB527517FF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2B313A4C-D3E7-4964-BA51-3401546B36C5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E5AAC31E-42DE-423E-8F43-A5600E24160F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D6E888EA-73A7-42B8-A617-621CF192F2A9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7D5F9D33-F74A-4FFB-9327-5CE691F0C1D6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"67E4D039-5BF8-469B-A6FE-A391A6D1BDA4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xp216_\\\\(eip\\\\)_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7E0BC528-5B72-48AB-A70A-B116770A8587\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xp216_\\\\(eip\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"33D044BD-12AD-42C9-B01C-957BEC6C6790\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18D7E470-D872-4C37-8669-B66328F173D6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"12512EC4-FB7D-420F-9A8A-547562BE1B49\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F51CE85F-16D1-4E49-83C7-70C90233E294\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B357AD42-1806-4BE5-B76D-F798E475F659\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"889CF2C0-EE6C-447F-85F1-005730EAD232\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr-300eec_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"17115730-97BF-473F-A4A7-03D5AE0F1A6D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6FF41E9F-4627-49EE-BCF1-08B5AADE964A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr-300poe_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18537338-DF5C-4F7A-995E-7F953B380657\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC118867-1A6C-4C3B-AD75-5D24551DB0BC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"64A47C63-7150-4F8D-BFD9-2F5C2761DBDF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0AC751E0-FC87-4DEB-85E8-C3E028B76482\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"36C9AE74-4683-4ED0-A605-3A6B065C230E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EB09860F-9DC8-476B-9AF7-6FFE57101D6C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4356417E-B4CB-45B0-B395-CE9D423FAB44\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1E6AB4BE-D669-4A95-8F8A-F2DA146D5FB1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F952542-6B79-4681-A236-15C188AAEB1E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1F4B8E2B-DEFF-4F1C-B5A4-0C4671C605C1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"664D9C76-BC13-4874-939C-A8211DA33903\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9F4DE2B7-1AB3-4BA5-B261-926B774B01DD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4834A67B-7B0B-4F88-BBFB-25667FD68EC5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr324wg_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"82D18854-D803-40C6-BB14-A28594C37CDB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E767C461-8FA6-4700-98CB-734AFD309140\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr326-2c_poe_wg_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4B7EC611-120E-4002-BF1E-4B45E431B7FC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr326-2c_poe_wg:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CBD19EFB-12D2-4401-B87A-91873528E474\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AFA83BBC-C6F3-4F98-A92B-2611EACBC093\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A5B7DEDC-66BD-4701-BBDD-16273263ADC9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FC8637DA-CA1E-46C6-AD1D-4F90B2A0BB35\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"080E722F-FCD4-4967-86EE-151ADC5702E7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BA8C39A2-1989-49ED-91FC-7BCE7002F250\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7DEEA300-16C3-4FEE-88A8-674DE2AEEC95\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BA970560-8AE2-49B1-BCD0-E7913DEA50ED\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AC7CB42C-666C-4DFD-B3CB-DD9509363E94\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A1509C8A-89FC-445D-BB22-BF9A811E853B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8709D27F-90B9-4AF8-8784-E974CE859518\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"756A07F8-4F9F-4A76-942E-82CB92216943\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"554455C1-19FF-4F71-BC36-13DDE7FE0087\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"67661569-6233-4C74-9C72-88BD14B257FE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"10F66ADC-91EC-4ED0-B768-03F94241B300\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0921AD23-44BA-4F5C-9DC8-A5F90753C977\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F41F6AE6-0E43-4D12-B379-FCF3A2A104DB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FDE5E54D-FFED-4C2C-B89D-E085E61D44E4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B0630BF0-8EFD-425A-A371-E1B0E5074D4D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3E048C4A-A414-4C87-A865-4D4218AE32EE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DEAA4C6F-F234-4895-9D0D-B89E3F07F038\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr528-6m_2hr2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"03DFEC43-5E84-460A-A50E-6BF378E83A70\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_l3_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"64CCA458-1F7F-44ED-ACD5-E9355B112194\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr528-6m_2hr2_l3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FD9EACF0-ECE5-40DD-8280-41707A637E9E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr528-6m_l3_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7B7870B9-F1CF-4503-A64C-6258FFB9D78D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr528-6m_l3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"81355370-BE69-434F-ABAC-8611F9909E46\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7319A333-EAA2-4ED2-A814-1AAEDFAC4E04\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AB16A0BE-5AF3-4168-B755-D023E497A35F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B490BBD4-458F-4077-8404-9208499226E7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"09743616-31C9-4E47-8A4A-B15D76204BE7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr552-12m_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"87B35693-9D07-4507-8070-43B8F756F772\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4A806691-3F4B-46AA-9718-2F6BF0FD3D7A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B05DE63D-186B-46CC-B3CE-66923F290B6B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr552-12m_2hr2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C97B2B53-F40E-4FB1-B3BA-5D0E0F8501F0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_l3_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EF61A53B-E4AD-4379-B053-1A25FDF65BD0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr552-12m_2hr2_l3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BA9921B1-38FD-4404-9986-3023C577FE5C\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-019200.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-710008.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T10:00:04.354Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-36324\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-18T15:12:22.854913Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-18T15:12:24.916Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RM1224 LTE(4G) EU\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RM1224 LTE(4G) NAM\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M804PB\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M812-1 ADSL-Router\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M812-1 ADSL-Router\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M816-1 ADSL-Router\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M816-1 ADSL-Router\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M826-2 SHDSL-Router\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M874-2\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M874-3\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M876-3\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M876-3 (ROK)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M876-4 (EU)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M876-4 (NAM)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE MUM853-1 (EU)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE MUM856-1 (EU)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE MUM856-1 (RoW)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE S615 LAN-Router\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V7.1.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC622-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.3.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC626-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.3.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC632-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.3.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC636-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.3.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC642-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.3.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE SC646-2C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.3.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W1748-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W1748-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W1788-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W1788-2 EEC M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W1788-2 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W1788-2IA M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W721-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W721-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W721-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W721-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W722-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W722-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W722-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W722-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W722-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W722-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W734-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W734-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W734-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W734-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W734-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W734-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W734-1 RJ45 (USA)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W734-1 RJ45 (USA)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W738-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W738-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W738-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W738-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W748-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W748-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W748-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W748-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W748-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W748-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W748-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W748-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W761-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W761-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W761-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W761-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W774-1 M12 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W774-1 M12 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W774-1 M12 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W774-1 M12 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W774-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W774-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W774-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W774-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W774-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W774-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W774-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W774-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W774-1 RJ45 (USA)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W774-1 RJ45 (USA)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W778-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W778-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W778-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W778-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W778-1 M12 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W778-1 M12 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W778-1 M12 EEC (USA)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W778-1 M12 EEC (USA)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-2 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-2 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-2 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-2 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-2 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-2 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-2 SFP\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-2 SFP\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-2 SFP\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-2 SFP\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-2IA RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-2IA RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-2IA RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W786-2IA RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-1 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-1 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 M12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 M12 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 M12 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 M12 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 M12 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 M12 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 M12 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE W788-2 RJ45\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM763-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM766-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM766-1 (US)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM766-1 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM766-1 EEC (US)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM763-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM763-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM766-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM766-1 (USA)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB205-3 (SC, PN)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB205-3 (ST, E/IP)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB205-3 (ST, E/IP)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB205-3 (ST, PN)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB205-3LD (SC, E/IP)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB205-3LD (SC, PN)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB208 (E/IP)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB208 (PN)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB213-3 (SC, E/IP)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB213-3 (SC, PN)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB213-3 (ST, E/IP)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB213-3 (ST, PN)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB213-3LD (SC, E/IP)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB213-3LD (SC, PN)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB216 (E/IP)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XB216 (PN)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC206-2 (SC)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC206-2 (ST/BFOC)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC206-2G PoE\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC206-2G PoE (54 V DC)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC206-2G PoE EEC (54 V DC)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC206-2SFP\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC206-2SFP EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC206-2SFP G\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC206-2SFP G (EIP DEF.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC206-2SFP G EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC208\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC208EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC208G\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC208G (EIP def.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC208G EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC208G PoE\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC208G PoE (54 V DC)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC216\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC216-3G PoE\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC216-3G PoE (54 V DC)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC216-4C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC216-4C G\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC216-4C G (EIP Def.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC216-4C G EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC216EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC224\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC224-4C G\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC224-4C G (EIP Def.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XC224-4C G EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XF204\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XF204 DNA\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XF204-2BA\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XF204-2BA DNA\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XM408-4C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XM408-4C (L3 int.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XM408-8C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XM408-8C (L3 int.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XM416-4C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XM416-4C (L3 int.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XP208\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XP208 (Ethernet/IP)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XP208EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XP208PoE EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XP216\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XP216 (Ethernet/IP)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XP216EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XP216POE EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR324WG (24 x FE, AC 230V)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR324WG (24 X FE, DC 24V)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR326-2C PoE WG\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR326-2C PoE WG (without UL)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR328-4C WG (28xGE, AC 230V)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR328-4C WG (28xGE, DC 24V)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR524-8C, 1x230V\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR524-8C, 1x230V (L3 int.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR524-8C, 24V\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR524-8C, 24V (L3 int.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR524-8C, 2x230V\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR524-8C, 2x230V (L3 int.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR526-8C, 1x230V\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR526-8C, 1x230V (L3 int.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR526-8C, 24V\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR526-8C, 24V (L3 int.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR526-8C, 2x230V\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR526-8C, 2x230V (L3 int.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR528-6M\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR528-6M (2HR2, L3 int.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR528-6M (2HR2)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR528-6M (L3 int.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR552-12M\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR552-12M (2HR2, L3 int.)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR552-12M (2HR2)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE XR552-12M (2HR2)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V6.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPLUS NET SCALANCE XC206-2\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPLUS NET SCALANCE XC206-2SFP\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPLUS NET SCALANCE XC208\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPLUS NET SCALANCE XC216-4C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.4\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-710008.html\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-019200.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-770\", \"description\": \"CWE-770: Allocation of Resources Without Limits or Throttling\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2026-04-14T08:35:27.763Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-36324\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-04-14T08:35:27.763Z\", \"dateReserved\": \"2022-07-20T00:00:00.000Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2022-08-10T11:18:39.000Z\", \"assignerShortName\": \"siemens\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
CNVD-2022-56475
Vulnerability from cnvd - Published: 2022-08-12用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/html/ssa-710008.html
| Name | ['SIEMENS SCALANCE M-800 / S615', 'Siemens SCALANCE W-700 IEEE 802.11ax family', 'Siemens SCALANCE W-700 IEEE 802.11n family', 'Siemens SCALANCE W-1700 IEEE 802.11ac family', 'Siemens SCALANCE XB-200 switch family', 'Siemens SCALANCE XC-200 switch family', 'Siemens SCALANCE XF-200BA switch family', 'Siemens SCALANCE XM-400 Family', 'Siemens SCALANCE XP-200 switch family', 'Siemens SCALANCE XR-300WG switch family', 'Siemens SCALANCE XR-500 Family'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2022-36324"
}
},
"description": "SCALANCE M-800\u3001MUM-800\u548cS615\u4ee5\u53caRUGGEDCOM RM1224\u5de5\u4e1a\u8def\u7531\u5668\u7528\u4e8e\u901a\u8fc7\u79fb\u52a8\u7f51\u7edc\uff08\u5982GPRS\u6216UMTS\uff09\u5b89\u5168\u8fdc\u7a0b\u8bbf\u95ee\u5de5\u5382\uff0c\u5e76\u5177\u6709\u9632\u706b\u5899\u7684\u96c6\u6210\u5b89\u5168\u529f\u80fd\uff0c\u4ee5\u9632\u6b62\u672a\u7ecf\u6388\u6743\u7684\u8bbf\u95ee\uff0c\u4ee5\u53caVPN\u6765\u4fdd\u62a4\u6570\u636e\u4f20\u8f93\u3002SCALANCE SC-600\u8bbe\u5907\uff08SC622-2C\u3001SC632-2C\u3001SC636-2C\uff0cSC642-2C\u3001SC646-2C\uff09\u7528\u4e8e\u4fdd\u62a4\u53d7\u4fe1\u4efb\u7684\u5de5\u4e1a\u7f51\u7edc\u514d\u53d7\u4e0d\u53d7\u4fe1\u4efb\u7684\u7f51\u7edc\u653b\u51fb\u3002\u5b83\u4eec\u5141\u8bb8\u4ee5\u4e0d\u540c\u7684\u65b9\u5f0f\u8fc7\u6ee4\u4f20\u5165\u548c\u4f20\u51fa\u7f51\u7edc\u8fde\u63a5\u3002SCALANCE W-1700\u4ea7\u54c1\u662f\u57fa\u4e8eIEEE 802.11ac\u6807\u51c6\u7684\u65e0\u7ebf\u901a\u4fe1\u8bbe\u5907\u3002SCALANCE W-700\u4ea7\u54c1\u662f\u57fa\u4e8eIEEE 802.11ax\u6807\u51c6\u7684\u65e0\u7ebf\u901a\u4fe1\u8bbe\u5907\u3002SCALANCE X switches\u7528\u4e8e\u8fde\u63a5\u5de5\u4e1a\u90e8\u4ef6\uff0c\u5982\u53ef\u7f16\u7a0b\u903b\u8f91\u63a7\u5236\u5668\uff08PLC\uff09\u6216\u4eba\u673a\u63a5\u53e3\uff08HMI\uff09\u3002\n\nSiemens SCALANCE\u4ea7\u54c1\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u662f\u7531\u4e8e\u53d7\u5f71\u54cd\u7684\u8bbe\u5907\u672a\u80fd\u6b63\u786e\u5904\u7406SSL/TLS\u53c2\u6570\u7684\u91cd\u65b0\u534f\u5546\u3002\u5141\u8bb8\u672a\u7ecf\u8eab\u4efd\u9a8c\u8bc1\u7684\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u7ed5\u8fc7TCP\u66b4\u529b\u9884\u9632\uff0c\u5e76\u5728\u653b\u51fb\u671f\u95f4\u5bfc\u81f4\u62d2\u7edd\u670d\u52a1\u60c5\u51b5\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-710008.html",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2022-56475",
"openTime": "2022-08-12",
"patchDescription": "SCALANCE M-800\u3001MUM-800\u548cS615\u4ee5\u53caRUGGEDCOM RM1224\u5de5\u4e1a\u8def\u7531\u5668\u7528\u4e8e\u901a\u8fc7\u79fb\u52a8\u7f51\u7edc\uff08\u5982GPRS\u6216UMTS\uff09\u5b89\u5168\u8fdc\u7a0b\u8bbf\u95ee\u5de5\u5382\uff0c\u5e76\u5177\u6709\u9632\u706b\u5899\u7684\u96c6\u6210\u5b89\u5168\u529f\u80fd\uff0c\u4ee5\u9632\u6b62\u672a\u7ecf\u6388\u6743\u7684\u8bbf\u95ee\uff0c\u4ee5\u53caVPN\u6765\u4fdd\u62a4\u6570\u636e\u4f20\u8f93\u3002SCALANCE SC-600\u8bbe\u5907\uff08SC622-2C\u3001SC632-2C\u3001SC636-2C\uff0cSC642-2C\u3001SC646-2C\uff09\u7528\u4e8e\u4fdd\u62a4\u53d7\u4fe1\u4efb\u7684\u5de5\u4e1a\u7f51\u7edc\u514d\u53d7\u4e0d\u53d7\u4fe1\u4efb\u7684\u7f51\u7edc\u653b\u51fb\u3002\u5b83\u4eec\u5141\u8bb8\u4ee5\u4e0d\u540c\u7684\u65b9\u5f0f\u8fc7\u6ee4\u4f20\u5165\u548c\u4f20\u51fa\u7f51\u7edc\u8fde\u63a5\u3002SCALANCE W-1700\u4ea7\u54c1\u662f\u57fa\u4e8eIEEE 802.11ac\u6807\u51c6\u7684\u65e0\u7ebf\u901a\u4fe1\u8bbe\u5907\u3002SCALANCE W-700\u4ea7\u54c1\u662f\u57fa\u4e8eIEEE 802.11ax\u6807\u51c6\u7684\u65e0\u7ebf\u901a\u4fe1\u8bbe\u5907\u3002SCALANCE X switches\u7528\u4e8e\u8fde\u63a5\u5de5\u4e1a\u90e8\u4ef6\uff0c\u5982\u53ef\u7f16\u7a0b\u903b\u8f91\u63a7\u5236\u5668\uff08PLC\uff09\u6216\u4eba\u673a\u63a5\u53e3\uff08HMI\uff09\u3002\r\n\r\nSiemens SCALANCE\u4ea7\u54c1\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u662f\u7531\u4e8e\u53d7\u5f71\u54cd\u7684\u8bbe\u5907\u672a\u80fd\u6b63\u786e\u5904\u7406SSL/TLS\u53c2\u6570\u7684\u91cd\u65b0\u534f\u5546\u3002\u5141\u8bb8\u672a\u7ecf\u8eab\u4efd\u9a8c\u8bc1\u7684\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u7ed5\u8fc7TCP\u66b4\u529b\u9884\u9632\uff0c\u5e76\u5728\u653b\u51fb\u671f\u95f4\u5bfc\u81f4\u62d2\u7edd\u670d\u52a1\u60c5\u51b5\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens SCALANCE\u4ea7\u54c1\u5b58\u5728\u672a\u660e\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"SIEMENS SCALANCE M-800 / S615",
"Siemens SCALANCE W-700 IEEE 802.11ax family",
"Siemens SCALANCE W-700 IEEE 802.11n family",
"Siemens SCALANCE W-1700 IEEE 802.11ac family",
"Siemens SCALANCE XB-200 switch family",
"Siemens SCALANCE XC-200 switch family",
"Siemens SCALANCE XF-200BA switch family",
"Siemens SCALANCE XM-400 Family",
"Siemens SCALANCE XP-200 switch family",
"Siemens SCALANCE XR-300WG switch family",
"Siemens SCALANCE XR-500 Family"
]
},
"referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html",
"serverity": "\u9ad8",
"submitTime": "2022-08-09",
"title": "Siemens SCALANCE\u4ea7\u54c1\u5b58\u5728\u672a\u660e\u6f0f\u6d1e"
}
GSD-2022-36324
Vulnerability from gsd - Updated: 2023-12-13 01:19{
"GSD": {
"alias": "CVE-2022-36324",
"description": "A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions). Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.",
"id": "GSD-2022-36324"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-36324"
],
"details": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.",
"id": "GSD-2022-36324",
"modified": "2023-12-13T01:19:21.106092Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-36324",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "RUGGEDCOM RM1224 LTE(4G) EU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "RUGGEDCOM RM1224 LTE(4G) NAM",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE M804PB",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE M812-1 ADSL-Router (Annex A)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE M812-1 ADSL-Router (Annex B)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE M816-1 ADSL-Router (Annex A)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE M816-1 ADSL-Router (Annex B)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE M826-2 SHDSL-Router",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE M874-2",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE M874-3",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE M876-3 (EVDO)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE M876-3 (ROK)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE M876-4 (EU)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE M876-4 (NAM)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE MUM853-1 (EU)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE MUM856-1 (EU)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE MUM856-1 (RoW)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE S615",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V7.1.2"
}
]
}
},
{
"product_name": "SCALANCE SC622-2C",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.3.1"
}
]
}
},
{
"product_name": "SCALANCE SC626-2C",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.3.1"
}
]
}
},
{
"product_name": "SCALANCE SC632-2C",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.3.1"
}
]
}
},
{
"product_name": "SCALANCE SC636-2C",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.3.1"
}
]
}
},
{
"product_name": "SCALANCE SC642-2C",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.3.1"
}
]
}
},
{
"product_name": "SCALANCE SC646-2C",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.3.1"
}
]
}
},
{
"product_name": "SCALANCE W1748-1 M12",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W1788-1 M12",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 EEC M12",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W1788-2 M12",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W1788-2IA M12",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W721-1 RJ45",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W722-1 RJ45",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W734-1 RJ45",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W734-1 RJ45 (USA)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W738-1 M12",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W748-1 M12",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W748-1 RJ45",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W761-1 RJ45",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W774-1 M12 EEC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W774-1 RJ45",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W774-1 RJ45 (USA)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W778-1 M12",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W778-1 M12 EEC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W778-1 M12 EEC (USA)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W786-1 RJ45",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W786-2 RJ45",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W786-2 SFP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W786-2IA RJ45",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W788-1 M12",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W788-1 RJ45",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W788-2 M12",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W788-2 M12 EEC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE W788-2 RJ45",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
},
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE WAM763-1",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.0"
}
]
}
},
{
"product_name": "SCALANCE WAM766-1 (EU)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.0"
}
]
}
},
{
"product_name": "SCALANCE WAM766-1 (US)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.0"
}
]
}
},
{
"product_name": "SCALANCE WAM766-1 EEC (EU)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.0"
}
]
}
},
{
"product_name": "SCALANCE WAM766-1 EEC (US)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.0"
}
]
}
},
{
"product_name": "SCALANCE WUM763-1",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.0"
},
{
"version_affected": "=",
"version_value": "All versions \u003c V2.0"
}
]
}
},
{
"product_name": "SCALANCE WUM766-1 (EU)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.0"
}
]
}
},
{
"product_name": "SCALANCE WUM766-1 (US)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.0"
}
]
}
},
{
"product_name": "SCALANCE XB205-3 (SC, PN)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XB205-3 (ST, E/IP)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
},
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XB205-3 (ST, PN)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XB205-3LD (SC, E/IP)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XB205-3LD (SC, PN)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XB208 (E/IP)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XB208 (PN)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XB213-3 (SC, E/IP)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XB213-3 (SC, PN)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XB213-3 (ST, E/IP)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XB213-3 (ST, PN)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XB213-3LD (SC, E/IP)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XB213-3LD (SC, PN)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XB216 (E/IP)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XB216 (PN)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC206-2 (SC)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC206-2 (ST/BFOC)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC206-2G PoE",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC206-2G PoE (54 V DC)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC206-2G PoE EEC (54 V DC)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC206-2SFP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC206-2SFP EEC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC206-2SFP G",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC206-2SFP G (EIP DEF.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC206-2SFP G EEC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC208",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC208EEC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC208G",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC208G (EIP def.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC208G EEC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC208G PoE",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC208G PoE (54 V DC)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC216",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC216-3G PoE",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC216-3G PoE (54 V DC)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC216-4C",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC216-4C G",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC216-4C G (EIP Def.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC216-4C G EEC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC216EEC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC224",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC224-4C G",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC224-4C G (EIP Def.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XC224-4C G EEC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XF204",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XF204 DNA",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XF204-2BA",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XF204-2BA DNA",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XM408-4C",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XM408-4C (L3 int.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XM408-8C",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XM408-8C (L3 int.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XM416-4C",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XM416-4C (L3 int.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XP208",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XP208 (Ethernet/IP)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XP208EEC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XP208PoE EEC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XP216",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XP216 (Ethernet/IP)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XP216EEC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XP216POE EEC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XR324WG (24 x FE, AC 230V)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XR324WG (24 X FE, DC 24V)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XR326-2C PoE WG",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XR326-2C PoE WG (without UL)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
},
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SCALANCE XR524-8C, 1x230V",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR524-8C, 1x230V (L3 int.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR524-8C, 24V",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR524-8C, 24V (L3 int.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR524-8C, 2x230V",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR524-8C, 2x230V (L3 int.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR526-8C, 1x230V",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR526-8C, 1x230V (L3 int.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR526-8C, 24V",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR526-8C, 24V (L3 int.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR526-8C, 2x230V",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR526-8C, 2x230V (L3 int.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR528-6M",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR528-6M (2HR2, L3 int.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR528-6M (2HR2)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR528-6M (L3 int.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR552-12M",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR552-12M (2HR2, L3 int.)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SCALANCE XR552-12M (2HR2)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
},
{
"version_affected": "=",
"version_value": "All versions \u003c V6.6"
}
]
}
},
{
"product_name": "SIPLUS NET SCALANCE XC206-2",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SIPLUS NET SCALANCE XC206-2SFP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SIPLUS NET SCALANCE XC208",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
},
{
"product_name": "SIPLUS NET SCALANCE XC216-4C",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.4"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack."
}
]
},
"impact": {
"cvss": [
{
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-770",
"lang": "eng",
"value": "CWE-770: Allocation of Resources Without Limits or Throttling"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ax_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ax:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ac_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ac:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr-300eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr-300poe_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324wg_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr326-2c_poe_wg_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr326-2c_poe_wg:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr528-6m_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr528-6m_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr552-12m_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-36324"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-770"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "N/A",
"refsource": "CONFIRM",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2023-02-23T16:19Z",
"publishedDate": "2022-08-10T12:15Z"
}
}
}
NCSC-2026-0112
Vulnerability from csaf_ncscnl - Published: 2026-04-14 11:37 - Updated: 2026-04-14 11:37Multiple SUSE Linux Enterprise kernel updates across versions 11, 12, and 15 addressed critical security vulnerabilities including use-after-free, heap overflows, race conditions, side-channel leaks, and Wi-Fi protocol flaws, alongside extensive non-security bug fixes.
CWE-306 - Missing Authentication for Critical Function| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
Multiple security vulnerabilities affecting NetBSD and various SUSE Linux Enterprise kernel versions include flaws in BPF verifier, Bluetooth, Wi-Fi fragmentation, heap overflows, use-after-free bugs, and EAPOL frame handling, with extensive non-security fixes across drivers and subsystems.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
Multiple vulnerabilities in WiFi protocols and drivers, including IEEE 802.11, ALFA Windows 10 driver 6.1316.1209 for AWUS036H, and Linux kernel implementations, allow attackers to inject arbitrary plaintext frames into protected networks across WPA3 and earlier standards.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
Multiple security vulnerabilities including Wi-Fi fragmentation flaws, use-after-free, denial-of-service, BPF verifier bugs, heap overflows, and race conditions have been addressed across various SUSE Linux Enterprise kernel updates and an ALFA Windows 10 driver for AWUS036H, impacting WPA/WPA2 networks and kernel stability.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
Multiple vulnerabilities in Linux kernel, ALFA Windows 10 driver for AWUS036ACH, and IEEE 802.11 protocols allow attackers to inject malicious WiFi frames and exfiltrate data across WEP, CCMP, GCMP, WPA3, and protected networks.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
Multiple vulnerabilities affect Samsung Galaxy S3 i9305 devices, Linux kernel WiFi implementations, and Windows Wireless Networking, allowing attackers to inject or spoof network packets by exploiting acceptance of plaintext A-MSDU frames with valid RFC1042 headers for EAPOL.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
Multiple vulnerabilities in WiFi implementations, including IEEE 802.11 standards and specific devices like Samsung Galaxy S3 i9305 on Android 4.4.4, allow attackers to inject malicious frames and exfiltrate data via fragmented frame reassembly flaws affecting WEP, WPA, WPA2, WPA3, CCMP, and GCMP protocols.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
Multiple SUSE Linux Enterprise kernel updates across versions 12, 15, and LTSS address critical security vulnerabilities including use-after-free, heap overflows, race conditions, and Wi-Fi protocol flaws, alongside extensive non-security bug fixes.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
Multiple OpenSSL versions prior to 1.1.1l and 1.0.2za contain buffer overrun and memory disclosure vulnerabilities in ASN.1 string processing, affecting various products including Oracle Siebel CRM, Oracle Communications, NetApp, HPE, and Solarwinds, with CVSS scores up to 7.4.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
A critical vulnerability in OpenSSL's BN_mod_sqrt() function causes infinite loops when parsing crafted certificates with invalid elliptic curve parameters, leading to denial of service across multiple OpenSSL versions and affecting various products including Node.js, Oracle, SAP, and NetApp.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
A vulnerability in the web interface's change password function allows low privileged users on affected devices to escalate their privileges.
CWE-862 - Missing Authorization| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
Siemens products including SCALANCE, SICAM, Tecnomatix, SITOP, and PowerSys contain vulnerabilities allowing authenticated remote attackers with administrative privileges to inject code or gain root shell access due to improper input sanitization.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
Affected devices improperly handle SSL/TLS renegotiation, allowing unauthenticated remote attackers to bypass TCP brute force protections and cause denial of service during the attack.
CWE-770 - Allocation of Resources Without Limits or Throttling| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
Affected devices improperly sanitize user input in their web interface, enabling an authenticated remote attacker with administrative privileges to execute a DOM-based cross-site scripting (XSS) attack.
CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
Multiple Siemens RUGGEDCOM and SCALANCE devices below versions V8.0 or V2.4.0 contain vulnerabilities allowing authenticated admin users to execute code or spawn root shells due to improper input sanitization, related to CVE-2022-36323.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
Multiple vulnerabilities affect the TCG TPM2.0 Reference implementation's CryptHmacSign function and various HPE servers, including local denial of service and out-of-bounds read issues, as detailed in Intel Security Advisory INTEL-SA-01209 and TCG advisories.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
Critical vulnerabilities in Oracle Communications Cloud Native Core Unified Data Repository and Oracle Siebel CRM Cloud Applications allow unauthenticated attackers full system compromise, while multiple SQLite and MySQL flaws affect NetApp and other vendors, causing memory corruption and potential data breaches.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
A vulnerability in multiple Siemens software products allows unauthenticated remote attackers to conduct man-in-the-middle attacks by exploiting improper validation of client certificates when connecting to the Analytics Service endpoint.
CWE-295 - Improper Certificate Validation| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
A vulnerability in SINEC NMS versions prior to V4.0 SP3 with UMC allows unauthenticated remote attackers to bypass authentication due to insufficient user identity validation in the UMC component.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
A vulnerability in SINEC NMS versions prior to V4.0 SP3 enables an authenticated remote attacker to bypass authorization controls and reset any user account password.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
A vulnerability in RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) before version 5.8 allows authenticated User Administrators to escalate privileges and gain access to any device group at any access level.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
A vulnerability in Industrial Edge Management Pro and Virtual allows unauthenticated remote attackers to bypass authentication and impersonate users by exploiting improperly enforced authentication on remote device connections when the feature is enabled and connection details are known.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Siemens / 6AG1206-2BB00-7AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1206-2Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1208-0Ba00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6Ag1216-4Bs00-7Ac2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2GF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5204-0BA00-2YF2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BB00-2TB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5205-3BF00-2TB2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2BD00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2GS00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5206-2RS00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AB2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0BA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2AC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2FC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5208-0GA00-2TC2 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5632-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5646-2GS00-2AC2 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5721-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5722-1FC00-0AB0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / 6GK5734-1FX00-0AA0 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / BFCClient
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE EU Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-7 LTE US Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1243-8 IRC Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / CP 1542SP-1 Firmware (OS)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Machine Insight App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - OPC UA Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Opc Ua Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - PROFINET IO Connector
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - SIMATIC S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge - Simatic S7 Connector App
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Pro V2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Industrial Edge Management Virtual
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Open PCS 7
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V8.2
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.0
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / OpenPCS 7 V9.1
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / ROX II Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM CROSSBOW Station Access Controller (SAC)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RM1224 LTE4G
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX MX5000RE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1400
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1500 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1510 FIRMWARE
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1511
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1524 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX1536
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM ROX RX5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / RUGGEDCOM RX1400 (Firmware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Eu
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rm1224 Lte Nam
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Mx5000
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1500
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1501
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / Ruggedcom Rox Rx1512
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M816-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M826-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M874-2 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-3 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE M876-4 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE MUM856-1 (Hardware)
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE S615
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC-600 Firmware
|
vers:unknown/* | ||
|
vers:unknown/*
Siemens / SCALANCE SC622-2C
|
vers:unknown/* |
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE"
}
},
"lang": "nl",
"notes": [
{
"category": "legal_disclaimer",
"text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings."
},
{
"category": "description",
"text": "Siemens heeft kwetsbaarheden verholpen in diverse producten zoals Analytics Toolkit, Ruggedcom, Industrial Edge Management Pro, SIDIS en TPM.\n\n\n",
"title": "Feiten"
},
{
"category": "description",
"text": "De kwetsbaarheden stellen een kwaadwillende mogelijk in staat aanvallen uit te voeren die kunnen leiden tot de volgende categorie\u00ebn schade:\n\n- Denial-of-Service (DoS)\n- Manipulatie van gegevens\n- Omzeilen van een beveiligingsmaatregel\n- (Remote) code execution (root/admin rechten)\n- Toegang tot systeemgegevens\n- Verhogen van rechten\n\nVoor succesvol misbruik van de genoemde kwetsbaarheden moet de kwaadwillende toegang hebben tot de productie-omgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.",
"title": "Interpretaties"
},
{
"category": "description",
"text": "Siemens heeft beveiligingsupdates uitgebracht om de kwetsbaarheden te verhelpen. Voor de kwetsbaarheden waar nog geen updates voor zijn, heeft Siemens mitigerende maatregelen gepubliceerd om de risico\u0027s zoveel als mogelijk te beperken. Zie de bijgevoegde referenties voor meer informatie.",
"title": "Oplossingen"
},
{
"category": "general",
"text": "medium",
"title": "Kans"
},
{
"category": "general",
"text": "high",
"title": "Schade"
},
{
"category": "general",
"text": "Improper Input Validation",
"title": "CWE-20"
},
{
"category": "general",
"text": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
"title": "CWE-74"
},
{
"category": "general",
"text": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"title": "CWE-79"
},
{
"category": "general",
"text": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
"title": "CWE-80"
},
{
"category": "general",
"text": "Improper Control of Resource Identifiers (\u0027Resource Injection\u0027)",
"title": "CWE-99"
},
{
"category": "general",
"text": "Out-of-bounds Read",
"title": "CWE-125"
},
{
"category": "general",
"text": "Numeric Truncation Error",
"title": "CWE-197"
},
{
"category": "general",
"text": "Incorrect Privilege Assignment",
"title": "CWE-266"
},
{
"category": "general",
"text": "Improper Access Control",
"title": "CWE-284"
},
{
"category": "general",
"text": "Improper Authentication",
"title": "CWE-287"
},
{
"category": "general",
"text": "Authentication Bypass by Spoofing",
"title": "CWE-290"
},
{
"category": "general",
"text": "Improper Certificate Validation",
"title": "CWE-295"
},
{
"category": "general",
"text": "Authentication Bypass by Primary Weakness",
"title": "CWE-305"
},
{
"category": "general",
"text": "Missing Authentication for Critical Function",
"title": "CWE-306"
},
{
"category": "general",
"text": "Improper Restriction of Excessive Authentication Attempts",
"title": "CWE-307"
},
{
"category": "general",
"text": "Use of a Broken or Risky Cryptographic Algorithm",
"title": "CWE-327"
},
{
"category": "general",
"text": "Insufficient Verification of Data Authenticity",
"title": "CWE-345"
},
{
"category": "general",
"text": "Origin Validation Error",
"title": "CWE-346"
},
{
"category": "general",
"text": "Improper Verification of Cryptographic Signature",
"title": "CWE-347"
},
{
"category": "general",
"text": "Improper Validation of Integrity Check Value",
"title": "CWE-354"
},
{
"category": "general",
"text": "Uncontrolled Resource Consumption",
"title": "CWE-400"
},
{
"category": "general",
"text": "Authorization Bypass Through User-Controlled Key",
"title": "CWE-639"
},
{
"category": "general",
"text": "Allocation of Resources Without Limits or Throttling",
"title": "CWE-770"
},
{
"category": "general",
"text": "Inclusion of Functionality from Untrusted Control Sphere",
"title": "CWE-829"
},
{
"category": "general",
"text": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)",
"title": "CWE-835"
},
{
"category": "general",
"text": "Missing Authorization",
"title": "CWE-862"
},
{
"category": "general",
"text": "Incorrect Authorization",
"title": "CWE-863"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "cert@ncsc.nl",
"name": "Nationaal Cyber Security Centrum",
"namespace": "https://www.ncsc.nl/"
},
"references": [
{
"category": "external",
"summary": "Reference",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-019200.html"
},
{
"category": "external",
"summary": "Reference",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-225816.html"
},
{
"category": "external",
"summary": "Reference",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-605717.html"
},
{
"category": "external",
"summary": "Reference",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-609469.html"
},
{
"category": "external",
"summary": "Reference",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-628843.html"
},
{
"category": "external",
"summary": "Reference",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-741509.html"
},
{
"category": "external",
"summary": "Reference",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-801704.html"
},
{
"category": "external",
"summary": "Reference",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-981622.html"
}
],
"title": "Kwetsbaarheden verholpen in Siemens producten",
"tracking": {
"current_release_date": "2026-04-14T11:37:21.682429Z",
"generator": {
"date": "2025-08-04T16:30:00Z",
"engine": {
"name": "V.A.",
"version": "1.3"
}
},
"id": "NCSC-2026-0112",
"initial_release_date": "2026-04-14T11:37:21.682429Z",
"revision_history": [
{
"date": "2026-04-14T11:37:21.682429Z",
"number": "1.0.0",
"summary": "Initiele versie"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-1"
}
}
],
"category": "product_name",
"name": "6AG1206-2BB00-7AC2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-2"
}
}
],
"category": "product_name",
"name": "6Ag1206-2Bs00-7Ac2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-3"
}
}
],
"category": "product_name",
"name": "6Ag1208-0Ba00-7Ac2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-4"
}
}
],
"category": "product_name",
"name": "6Ag1216-4Bs00-7Ac2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-5"
}
}
],
"category": "product_name",
"name": "6GK5204-0BA00-2GF2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-6"
}
}
],
"category": "product_name",
"name": "6GK5204-0BA00-2YF2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-7"
}
}
],
"category": "product_name",
"name": "6GK5205-3BB00-2AB2 FIRMWARE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-8"
}
}
],
"category": "product_name",
"name": "6GK5205-3BB00-2AB2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-9"
}
}
],
"category": "product_name",
"name": "6GK5205-3BB00-2TB2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-10"
}
}
],
"category": "product_name",
"name": "6GK5205-3BF00-2TB2 FIRMWARE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-11"
}
}
],
"category": "product_name",
"name": "6GK5206-2BD00-2AC2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-12"
}
}
],
"category": "product_name",
"name": "6GK5206-2GS00-2AC2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-13"
}
}
],
"category": "product_name",
"name": "6GK5206-2GS00-2TC2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-14"
}
}
],
"category": "product_name",
"name": "6GK5206-2RS00-2AC2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-15"
}
}
],
"category": "product_name",
"name": "6GK5208-0BA00-2AB2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-16"
}
}
],
"category": "product_name",
"name": "6GK5208-0BA00-2AC2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-17"
}
}
],
"category": "product_name",
"name": "6GK5208-0BA00-2FC2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-18"
}
}
],
"category": "product_name",
"name": "6GK5208-0GA00-2AC2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-19"
}
}
],
"category": "product_name",
"name": "6GK5208-0GA00-2FC2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-20"
}
}
],
"category": "product_name",
"name": "6GK5208-0GA00-2TC2 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-21"
}
}
],
"category": "product_name",
"name": "6GK5632-2GS00-2AC2 FIRMWARE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-22"
}
}
],
"category": "product_name",
"name": "6GK5646-2GS00-2AC2 FIRMWARE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-23"
}
}
],
"category": "product_name",
"name": "6GK5721-1FC00-0AB0 FIRMWARE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-24"
}
}
],
"category": "product_name",
"name": "6GK5722-1FC00-0AB0 FIRMWARE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-25"
}
}
],
"category": "product_name",
"name": "6GK5734-1FX00-0AA0 FIRMWARE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-26"
}
}
],
"category": "product_name",
"name": "BFCClient"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-27"
}
}
],
"category": "product_name",
"name": "CP 1243-1 Firmware (OS)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-28"
}
}
],
"category": "product_name",
"name": "CP 1243-7 LTE EU Firmware (OS)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-29"
}
}
],
"category": "product_name",
"name": "CP 1243-7 LTE US Firmware (OS)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-30"
}
}
],
"category": "product_name",
"name": "CP 1243-8 IRC Firmware (OS)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-31"
}
}
],
"category": "product_name",
"name": "CP 1542SP-1 Firmware (OS)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-32"
}
}
],
"category": "product_name",
"name": "Industrial Edge - Machine Insight App"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-33"
}
}
],
"category": "product_name",
"name": "Industrial Edge - OPC UA Connector"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-34"
}
}
],
"category": "product_name",
"name": "Industrial Edge - Opc Ua Connector"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-35"
}
}
],
"category": "product_name",
"name": "Industrial Edge - PROFINET IO Connector"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-36"
}
}
],
"category": "product_name",
"name": "Industrial Edge - SIMATIC S7 Connector App"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-37"
}
}
],
"category": "product_name",
"name": "Industrial Edge - Simatic S7 Connector App"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-38"
}
}
],
"category": "product_name",
"name": "Industrial Edge Management"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-39"
}
}
],
"category": "product_name",
"name": "Industrial Edge Management Pro V1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-40"
}
}
],
"category": "product_name",
"name": "Industrial Edge Management Pro V2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-41"
}
}
],
"category": "product_name",
"name": "Industrial Edge Management Virtual"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-42"
}
}
],
"category": "product_name",
"name": "Open PCS 7"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-43"
}
}
],
"category": "product_name",
"name": "OpenPCS 7 V8.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-44"
}
}
],
"category": "product_name",
"name": "OpenPCS 7 V9.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-45"
}
}
],
"category": "product_name",
"name": "OpenPCS 7 V9.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-46"
}
}
],
"category": "product_name",
"name": "ROX II Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-47"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-48"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM CROSSBOW Station Access Controller (SAC)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-49"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RM1224 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-50"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RM1224 LTE(4G) EU"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-51"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-52"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RM1224 LTE(4G) NAM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-53"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-54"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RM1224 LTE4G"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-55"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX MX5000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-56"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX MX5000RE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-57"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1400"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-58"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1500"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-59"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1500 FIRMWARE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-60"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1501"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-61"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1510"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-62"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1510 FIRMWARE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-63"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1511"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-64"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1512"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-65"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1524"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-66"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1524 (Hardware)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-67"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX1536"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-68"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM ROX RX5000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-69"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RX1400 (Firmware)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-70"
}
}
],
"category": "product_name",
"name": "Ruggedcom Rm1224 Lte Eu"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-71"
}
}
],
"category": "product_name",
"name": "Ruggedcom Rm1224 Lte Nam"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-72"
}
}
],
"category": "product_name",
"name": "Ruggedcom Rox Mx5000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-73"
}
}
],
"category": "product_name",
"name": "Ruggedcom Rox Rx1500"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-74"
}
}
],
"category": "product_name",
"name": "Ruggedcom Rox Rx1501"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-75"
}
}
],
"category": "product_name",
"name": "Ruggedcom Rox Rx1512"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-76"
}
}
],
"category": "product_name",
"name": "SCALANCE M816-1 (Hardware)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-77"
}
}
],
"category": "product_name",
"name": "SCALANCE M826-2 (Hardware)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-78"
}
}
],
"category": "product_name",
"name": "SCALANCE M874-2 (Hardware)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-79"
}
}
],
"category": "product_name",
"name": "SCALANCE M876-3 (Hardware)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-80"
}
}
],
"category": "product_name",
"name": "SCALANCE M876-4 (Hardware)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-81"
}
}
],
"category": "product_name",
"name": "SCALANCE MUM856-1 (Hardware)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-82"
}
}
],
"category": "product_name",
"name": "SCALANCE S615"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-83"
}
}
],
"category": "product_name",
"name": "SCALANCE SC-600 Firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-84"
}
}
],
"category": "product_name",
"name": "SCALANCE SC622-2C"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-24588",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "other",
"text": "Missing Authentication for Critical Function",
"title": "CWE-306"
},
{
"category": "other",
"text": "Improper Control of Resource Identifiers (\u0027Resource Injection\u0027)",
"title": "CWE-99"
},
{
"category": "other",
"text": "Use of a Broken or Risky Cryptographic Algorithm",
"title": "CWE-327"
},
{
"category": "description",
"text": "Multiple SUSE Linux Enterprise kernel updates across versions 11, 12, and 15 addressed critical security vulnerabilities including use-after-free, heap overflows, race conditions, side-channel leaks, and Wi-Fi protocol flaws, alongside extensive non-security bug fixes.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2020-24588 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2020/cve-2020-24588.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2020-24588"
},
{
"cve": "CVE-2020-26139",
"cwe": {
"id": "CWE-829",
"name": "Inclusion of Functionality from Untrusted Control Sphere"
},
"notes": [
{
"category": "other",
"text": "Inclusion of Functionality from Untrusted Control Sphere",
"title": "CWE-829"
},
{
"category": "description",
"text": "Multiple security vulnerabilities affecting NetBSD and various SUSE Linux Enterprise kernel versions include flaws in BPF verifier, Bluetooth, Wi-Fi fragmentation, heap overflows, use-after-free bugs, and EAPOL frame handling, with extensive non-security fixes across drivers and subsystems.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2020-26139 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2020/cve-2020-26139.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2020-26139"
},
{
"cve": "CVE-2020-26140",
"cwe": {
"id": "CWE-346",
"name": "Origin Validation Error"
},
"notes": [
{
"category": "other",
"text": "Origin Validation Error",
"title": "CWE-346"
},
{
"category": "other",
"text": "Improper Control of Resource Identifiers (\u0027Resource Injection\u0027)",
"title": "CWE-99"
},
{
"category": "other",
"text": "Use of a Broken or Risky Cryptographic Algorithm",
"title": "CWE-327"
},
{
"category": "description",
"text": "Multiple vulnerabilities in WiFi protocols and drivers, including IEEE 802.11, ALFA Windows 10 driver 6.1316.1209 for AWUS036H, and Linux kernel implementations, allow attackers to inject arbitrary plaintext frames into protected networks across WPA3 and earlier standards.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2020-26140 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2020/cve-2020-26140.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2020-26140"
},
{
"cve": "CVE-2020-26141",
"cwe": {
"id": "CWE-863",
"name": "Incorrect Authorization"
},
"notes": [
{
"category": "other",
"text": "Incorrect Authorization",
"title": "CWE-863"
},
{
"category": "other",
"text": "Improper Validation of Integrity Check Value",
"title": "CWE-354"
},
{
"category": "description",
"text": "Multiple security vulnerabilities including Wi-Fi fragmentation flaws, use-after-free, denial-of-service, BPF verifier bugs, heap overflows, and race conditions have been addressed across various SUSE Linux Enterprise kernel updates and an ALFA Windows 10 driver for AWUS036H, impacting WPA/WPA2 networks and kernel stability.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2020-26141 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2020/cve-2020-26141.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2020-26141"
},
{
"cve": "CVE-2020-26143",
"cwe": {
"id": "CWE-346",
"name": "Origin Validation Error"
},
"notes": [
{
"category": "other",
"text": "Origin Validation Error",
"title": "CWE-346"
},
{
"category": "other",
"text": "Improper Control of Resource Identifiers (\u0027Resource Injection\u0027)",
"title": "CWE-99"
},
{
"category": "description",
"text": "Multiple vulnerabilities in Linux kernel, ALFA Windows 10 driver for AWUS036ACH, and IEEE 802.11 protocols allow attackers to inject malicious WiFi frames and exfiltrate data across WEP, CCMP, GCMP, WPA3, and protected networks.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2020-26143 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2020/cve-2020-26143.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2020-26143"
},
{
"cve": "CVE-2020-26144",
"cwe": {
"id": "CWE-290",
"name": "Authentication Bypass by Spoofing"
},
"notes": [
{
"category": "other",
"text": "Authentication Bypass by Spoofing",
"title": "CWE-290"
},
{
"category": "description",
"text": "Multiple vulnerabilities affect Samsung Galaxy S3 i9305 devices, Linux kernel WiFi implementations, and Windows Wireless Networking, allowing attackers to inject or spoof network packets by exploiting acceptance of plaintext A-MSDU frames with valid RFC1042 headers for EAPOL.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2020-26144 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2020/cve-2020-26144.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2020-26144"
},
{
"cve": "CVE-2020-26146",
"cwe": {
"id": "CWE-307",
"name": "Improper Restriction of Excessive Authentication Attempts"
},
"notes": [
{
"category": "other",
"text": "Improper Restriction of Excessive Authentication Attempts",
"title": "CWE-307"
},
{
"category": "other",
"text": "Improper Control of Resource Identifiers (\u0027Resource Injection\u0027)",
"title": "CWE-99"
},
{
"category": "description",
"text": "Multiple vulnerabilities in WiFi implementations, including IEEE 802.11 standards and specific devices like Samsung Galaxy S3 i9305 on Android 4.4.4, allow attackers to inject malicious frames and exfiltrate data via fragmented frame reassembly flaws affecting WEP, WPA, WPA2, WPA3, CCMP, and GCMP protocols.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2020-26146 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2020/cve-2020-26146.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2020-26146"
},
{
"cve": "CVE-2020-26147",
"cwe": {
"id": "CWE-307",
"name": "Improper Restriction of Excessive Authentication Attempts"
},
"notes": [
{
"category": "other",
"text": "Improper Restriction of Excessive Authentication Attempts",
"title": "CWE-307"
},
{
"category": "other",
"text": "Improper Control of Resource Identifiers (\u0027Resource Injection\u0027)",
"title": "CWE-99"
},
{
"category": "description",
"text": "Multiple SUSE Linux Enterprise kernel updates across versions 12, 15, and LTSS address critical security vulnerabilities including use-after-free, heap overflows, race conditions, and Wi-Fi protocol flaws, alongside extensive non-security bug fixes.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2020-26147 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2020/cve-2020-26147.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2020-26147"
},
{
"cve": "CVE-2021-3712",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "other",
"text": "Out-of-bounds Read",
"title": "CWE-125"
},
{
"category": "description",
"text": "Multiple OpenSSL versions prior to 1.1.1l and 1.0.2za contain buffer overrun and memory disclosure vulnerabilities in ASN.1 string processing, affecting various products including Oracle Siebel CRM, Oracle Communications, NetApp, HPE, and Solarwinds, with CVSS scores up to 7.4.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2021-3712 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2021/cve-2021-3712.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2021-3712"
},
{
"cve": "CVE-2022-0778",
"cwe": {
"id": "CWE-835",
"name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)"
},
"notes": [
{
"category": "other",
"text": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)",
"title": "CWE-835"
},
{
"category": "description",
"text": "A critical vulnerability in OpenSSL\u0027s BN_mod_sqrt() function causes infinite loops when parsing crafted certificates with invalid elliptic curve parameters, leading to denial of service across multiple OpenSSL versions and affecting various products including Node.js, Oracle, SAP, and NetApp.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2022-0778 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2022/cve-2022-0778.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2022-0778"
},
{
"cve": "CVE-2022-31765",
"cwe": {
"id": "CWE-862",
"name": "Missing Authorization"
},
"notes": [
{
"category": "other",
"text": "Missing Authorization",
"title": "CWE-862"
},
{
"category": "description",
"text": "A vulnerability in the web interface\u0027s change password function allows low privileged users on affected devices to escalate their privileges.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2022-31765 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2022/cve-2022-31765.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2022-31765"
},
{
"cve": "CVE-2022-36323",
"notes": [
{
"category": "description",
"text": "Siemens products including SCALANCE, SICAM, Tecnomatix, SITOP, and PowerSys contain vulnerabilities allowing authenticated remote attackers with administrative privileges to inject code or gain root shell access due to improper input sanitization.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2022-36323 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2022/cve-2022-36323.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2022-36323"
},
{
"cve": "CVE-2022-36324",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "other",
"text": "Allocation of Resources Without Limits or Throttling",
"title": "CWE-770"
},
{
"category": "description",
"text": "Affected devices improperly handle SSL/TLS renegotiation, allowing unauthenticated remote attackers to bypass TCP brute force protections and cause denial of service during the attack.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2022-36324 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2022/cve-2022-36324.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2022-36324"
},
{
"cve": "CVE-2022-36325",
"cwe": {
"id": "CWE-80",
"name": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
},
"notes": [
{
"category": "other",
"text": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
"title": "CWE-80"
},
{
"category": "description",
"text": "Affected devices improperly sanitize user input in their web interface, enabling an authenticated remote attacker with administrative privileges to execute a DOM-based cross-site scripting (XSS) attack.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2022-36325 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2022/cve-2022-36325.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2022-36325"
},
{
"cve": "CVE-2023-44373",
"notes": [
{
"category": "description",
"text": "Multiple Siemens RUGGEDCOM and SCALANCE devices below versions V8.0 or V2.4.0 contain vulnerabilities allowing authenticated admin users to execute code or spawn root shells due to improper input sanitization, related to CVE-2022-36323.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2023-44373 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2023/cve-2023-44373.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2023-44373"
},
{
"cve": "CVE-2025-2884",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "other",
"text": "Out-of-bounds Read",
"title": "CWE-125"
},
{
"category": "description",
"text": "Multiple vulnerabilities affect the TCG TPM2.0 Reference implementation\u0027s CryptHmacSign function and various HPE servers, including local denial of service and out-of-bounds read issues, as detailed in Intel Security Advisory INTEL-SA-01209 and TCG advisories.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-2884 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-2884.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2025-2884"
},
{
"cve": "CVE-2025-6965",
"cwe": {
"id": "CWE-197",
"name": "Numeric Truncation Error"
},
"notes": [
{
"category": "other",
"text": "Numeric Truncation Error",
"title": "CWE-197"
},
{
"category": "description",
"text": "Critical vulnerabilities in Oracle Communications Cloud Native Core Unified Data Repository and Oracle Siebel CRM Cloud Applications allow unauthenticated attackers full system compromise, while multiple SQLite and MySQL flaws affect NetApp and other vendors, causing memory corruption and potential data breaches.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:L/VI:H/VA:L/SC:L/SI:H/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:N/R:U/V:D/RE:L/U:Green",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-6965 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-6965.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2025-6965"
},
{
"cve": "CVE-2025-40745",
"cwe": {
"id": "CWE-295",
"name": "Improper Certificate Validation"
},
"notes": [
{
"category": "other",
"text": "Improper Certificate Validation",
"title": "CWE-295"
},
{
"category": "description",
"text": "A vulnerability in multiple Siemens software products allows unauthenticated remote attackers to conduct man-in-the-middle attacks by exploiting improper validation of client certificates when connecting to the Analytics Service endpoint.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-40745 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-40745.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2025-40745"
},
{
"cve": "CVE-2026-24032",
"cwe": {
"id": "CWE-347",
"name": "Improper Verification of Cryptographic Signature"
},
"notes": [
{
"category": "other",
"text": "Improper Verification of Cryptographic Signature",
"title": "CWE-347"
},
{
"category": "description",
"text": "A vulnerability in SINEC NMS versions prior to V4.0 SP3 with UMC allows unauthenticated remote attackers to bypass authentication due to insufficient user identity validation in the UMC component.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2026-24032 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2026/cve-2026-24032.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2026-24032"
},
{
"cve": "CVE-2026-25654",
"cwe": {
"id": "CWE-639",
"name": "Authorization Bypass Through User-Controlled Key"
},
"notes": [
{
"category": "other",
"text": "Authorization Bypass Through User-Controlled Key",
"title": "CWE-639"
},
{
"category": "description",
"text": "A vulnerability in SINEC NMS versions prior to V4.0 SP3 enables an authenticated remote attacker to bypass authorization controls and reset any user account password.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2026-25654 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2026/cve-2026-25654.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2026-25654"
},
{
"cve": "CVE-2026-27668",
"cwe": {
"id": "CWE-266",
"name": "Incorrect Privilege Assignment"
},
"notes": [
{
"category": "other",
"text": "Incorrect Privilege Assignment",
"title": "CWE-266"
},
{
"category": "description",
"text": "A vulnerability in RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) before version 5.8 allows authenticated User Administrators to escalate privileges and gain access to any device group at any access level.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2026-27668 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2026/cve-2026-27668.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2026-27668"
},
{
"cve": "CVE-2026-33892",
"cwe": {
"id": "CWE-305",
"name": "Authentication Bypass by Primary Weakness"
},
"notes": [
{
"category": "other",
"text": "Authentication Bypass by Primary Weakness",
"title": "CWE-305"
},
{
"category": "description",
"text": "A vulnerability in Industrial Edge Management Pro and Virtual allows unauthenticated remote attackers to bypass authentication and impersonate users by exploiting improperly enforced authentication on remote device connections when the feature is enabled and connection details are known.",
"title": "Summary"
},
{
"category": "general",
"text": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L",
"title": "CVSSV4"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2026-33892 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2026/cve-2026-33892.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2",
"CSAFPID-3",
"CSAFPID-4",
"CSAFPID-5",
"CSAFPID-6",
"CSAFPID-7",
"CSAFPID-8",
"CSAFPID-9",
"CSAFPID-10",
"CSAFPID-11",
"CSAFPID-12",
"CSAFPID-13",
"CSAFPID-14",
"CSAFPID-15",
"CSAFPID-16",
"CSAFPID-17",
"CSAFPID-18",
"CSAFPID-19",
"CSAFPID-20",
"CSAFPID-21",
"CSAFPID-22",
"CSAFPID-23",
"CSAFPID-24",
"CSAFPID-25",
"CSAFPID-26",
"CSAFPID-27",
"CSAFPID-28",
"CSAFPID-29",
"CSAFPID-30",
"CSAFPID-31",
"CSAFPID-32",
"CSAFPID-33",
"CSAFPID-34",
"CSAFPID-35",
"CSAFPID-36",
"CSAFPID-37",
"CSAFPID-38",
"CSAFPID-39",
"CSAFPID-40",
"CSAFPID-41",
"CSAFPID-42",
"CSAFPID-43",
"CSAFPID-44",
"CSAFPID-45",
"CSAFPID-46",
"CSAFPID-47",
"CSAFPID-48",
"CSAFPID-49",
"CSAFPID-50",
"CSAFPID-51",
"CSAFPID-52",
"CSAFPID-53",
"CSAFPID-54",
"CSAFPID-55",
"CSAFPID-56",
"CSAFPID-57",
"CSAFPID-58",
"CSAFPID-59",
"CSAFPID-60",
"CSAFPID-61",
"CSAFPID-62",
"CSAFPID-63",
"CSAFPID-64",
"CSAFPID-65",
"CSAFPID-66",
"CSAFPID-67",
"CSAFPID-68",
"CSAFPID-69",
"CSAFPID-70",
"CSAFPID-71",
"CSAFPID-72",
"CSAFPID-73",
"CSAFPID-74",
"CSAFPID-75",
"CSAFPID-76",
"CSAFPID-77",
"CSAFPID-78",
"CSAFPID-79",
"CSAFPID-80",
"CSAFPID-81",
"CSAFPID-82",
"CSAFPID-83",
"CSAFPID-84"
]
}
],
"title": "CVE-2026-33892"
}
]
}
BDU:2022-04991
Vulnerability from fstec - Published: 09.08.2022{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Siemens AG",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "- (SCALANCE S615), - (SCALANCE W-700), - (SCALANCE W1700), - (SCALANCE M-800), \u0434\u043e 2.3.1 (SCALANCE SC-600), - (SCALANCE XB-200), - (SCALANCE XC-200), - (SCALANCE XF-200BA), - (SCALANCE XM-400), - (SCALANCE XP-200), - (SCALANCE XR-300WG), - (SCALANCE XR-500)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0423\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0430 \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0439 \u0438\u0437 \u0434\u043e\u0432\u0435\u0440\u0435\u043d\u043d\u044b\u0445 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u043e\u0432.\n\u0412 \u0441\u0432\u044f\u0437\u0438 \u0441\u043e \u0441\u043b\u043e\u0436\u0438\u0432\u0448\u0435\u0439\u0441\u044f \u043e\u0431\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u043e\u0439 \u0438 \u0432\u0432\u0435\u0434\u0435\u043d\u043d\u044b\u043c\u0438 \u0441\u0430\u043d\u043a\u0446\u0438\u044f\u043c\u0438 \u043f\u0440\u043e\u0442\u0438\u0432 \u0420\u043e\u0441\u0441\u0438\u0439\u0441\u043a\u043e\u0439 \u0424\u0435\u0434\u0435\u0440\u0430\u0446\u0438\u0438 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u0442\u0441\u044f \u0443\u0441\u0442\u0430\u043d\u0430\u0432\u043b\u0438\u0432\u0430\u0442\u044c \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0442\u043e\u043b\u044c\u043a\u043e \u043f\u043e\u0441\u043b\u0435 \u043e\u0446\u0435\u043d\u043a\u0438 \u0432\u0441\u0435\u0445 \u0441\u043e\u043f\u0443\u0442\u0441\u0442\u0432\u0443\u044e\u0449\u0438\u0445 \u0440\u0438\u0441\u043a\u043e\u0432.\n\n\u041a\u043e\u043c\u043f\u0435\u043d\u0441\u0438\u0440\u0443\u044e\u0449\u0438\u0435 \u043c\u0435\u0440\u044b:\n- \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u043f\u043e\u0440\u0442\u0430\u043c 80/TCP \u0438 443/TCP;\n- \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044e \u0438\u0437 \u043e\u0431\u0449\u0435\u0434\u043e\u0441\u0442\u0443\u043f\u043d\u044b\u0445 \u0441\u0435\u0442\u0435\u0439 (\u0418\u043d\u0442\u0435\u0440\u043d\u0435\u0442);\n- \u043e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430\u043c \u0442\u043e\u043b\u044c\u043a\u043e \u0438\u0437 \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0430 \u0441\u0435\u0442\u0438 (\u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0435\u0442\u0438);\n- \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0432\u0441\u0442\u0440\u043e\u0435\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0440\u0430\u0437\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u0430;\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0432\u0438\u0440\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0445 \u0447\u0430\u0441\u0442\u043d\u044b\u0445 \u0441\u0435\u0442\u0435\u0439 \u0434\u043b\u044f \u043e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u0438 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430 (VPN).\n\n\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f:\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "09.08.2022",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "15.08.2022",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "15.08.2022",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2022-04991",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2022-36324",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438 \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0443\u0435\u0442",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "SCALANCE S615, SCALANCE W-700, SCALANCE W1700, SCALANCE M-800, SCALANCE SC-600, SCALANCE XB-200, SCALANCE XC-200, SCALANCE XF-200BA, SCALANCE XM-400, SCALANCE XP-200, SCALANCE XR-300WG, SCALANCE XR-500",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f Siemens, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043d\u0435\u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u043c \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435\u043c \u0440\u0435\u0441\u0443\u0440\u0441\u043e\u0432, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u043e\u0435 \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u043e\u0432 \u0438\u043b\u0438 \u0434\u0440\u043e\u0441\u0441\u0435\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 (CWE-770)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f Siemens \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043d\u0435\u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u043c \u0440\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u0435\u043c \u0440\u0435\u0441\u0443\u0440\u0441\u043e\u0432. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043c\u0435\u0440\u044b",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u0430\u043c\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u041e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0410\u0421\u0423 \u0422\u041f, \u041f\u041e \u0441\u0435\u0442\u0435\u0432\u043e\u0433\u043e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-770",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,8)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,5)"
}
ICSA-22-223-07
Vulnerability from csaf_cisa - Published: 2022-08-09 00:00 - Updated: 2026-04-16 06:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
6GK6108-4AM00-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
6GK6108-4AM00-2DA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M804PB (6GK5804-0AP00-2AA2)
Siemens / SCALANCE M804PB (6GK5804-0AP00-2AA2)
|
6GK5804-0AP00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
Siemens / SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
|
6GK5812-1AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
Siemens / SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
|
6GK5812-1BA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
Siemens / SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
|
6GK5816-1AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
Siemens / SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
|
6GK5816-1BA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
Siemens / SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
|
6GK5826-2AB00-2AB2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-2 (6GK5874-2AA00-2AA2)
Siemens / SCALANCE M874-2 (6GK5874-2AA00-2AA2)
|
6GK5874-2AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-3 (6GK5874-3AA00-2AA2)
Siemens / SCALANCE M874-3 (6GK5874-3AA00-2AA2)
|
6GK5874-3AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-3 (6GK5876-3AA02-2BA2)
Siemens / SCALANCE M876-3 (6GK5876-3AA02-2BA2)
|
6GK5876-3AA02-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)
Siemens / SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)
|
6GK5876-3AA02-2EA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)
Siemens / SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)
|
6GK5876-4AA00-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)
Siemens / SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)
|
6GK5876-4AA00-2DA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)
Siemens / SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)
|
6GK5853-2EA00-2DA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)
Siemens / SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)
|
6GK5856-2EA00-3DA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)
Siemens / SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)
|
6GK5856-2EA00-3AA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)
Siemens / SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)
|
6GK5615-0AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC622-2C (6GK5622-2GS00-2AC2)
Siemens / SCALANCE SC622-2C (6GK5622-2GS00-2AC2)
|
6GK5622-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC626-2C (6GK5626-2GS00-2AC2)
Siemens / SCALANCE SC626-2C (6GK5626-2GS00-2AC2)
|
6GK5626-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC632-2C (6GK5632-2GS00-2AC2)
Siemens / SCALANCE SC632-2C (6GK5632-2GS00-2AC2)
|
6GK5632-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE SC636-2C (6GK5636-2GS00-2AC2)
Siemens / SCALANCE SC636-2C (6GK5636-2GS00-2AC2)
|
6GK5636-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE SC642-2C (6GK5642-2GS00-2AC2)
Siemens / SCALANCE SC642-2C (6GK5642-2GS00-2AC2)
|
6GK5642-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE SC646-2C (6GK5646-2GS00-2AC2)
Siemens / SCALANCE SC646-2C (6GK5646-2GS00-2AC2)
|
6GK5646-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)
Siemens / SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)
|
6GK5748-1GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)
Siemens / SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)
|
6GK5748-1GY01-0TA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)
Siemens / SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)
|
6GK5788-1GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)
Siemens / SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)
|
6GK5788-2GY01-0TA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)
Siemens / SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)
|
6GK5788-2GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)
Siemens / SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)
|
6GK5788-2HY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)
Siemens / SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)
|
6GK5763-1AL00-7DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)
Siemens / SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)
|
6GK5766-1GE00-7DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)
Siemens / SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)
|
6GK5766-1GE00-7DB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)
Siemens / SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)
|
6GK5766-1GE00-7TA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)
Siemens / SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)
|
6GK5766-1GE00-7TB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)
Siemens / SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)
|
6GK5763-1AL00-3AA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)
Siemens / SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)
|
6GK5763-1AL00-3DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)
Siemens / SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)
|
6GK5766-1GE00-3DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)
Siemens / SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)
|
6GK5766-1GE00-3DB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)
Siemens / SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)
|
6GK5205-3BB00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)
Siemens / SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)
|
6GK5205-3BB00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)
Siemens / SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)
|
6GK5205-3BD00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)
Siemens / SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)
|
6GK5205-3BD00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)
Siemens / SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)
|
6GK5205-3BF00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)
Siemens / SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)
|
6GK5205-3BF00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)
Siemens / SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)
|
6GK5208-0BA00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)
Siemens / SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)
|
6GK5208-0BA00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)
Siemens / SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)
|
6GK5213-3BD00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)
Siemens / SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)
|
6GK5213-3BD00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)
Siemens / SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)
|
6GK5213-3BB00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)
Siemens / SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)
|
6GK5213-3BB00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)
Siemens / SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)
|
6GK5213-3BF00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)
Siemens / SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)
|
6GK5213-3BF00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)
Siemens / SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)
|
6GK5216-0BA00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)
Siemens / SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)
|
6GK5216-0BA00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)
Siemens / SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)
|
6GK5206-2BD00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)
Siemens / SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)
|
6GK5206-2BB00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)
Siemens / SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)
|
6GK5206-2RS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)
Siemens / SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)
|
6GK5206-2RS00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)
Siemens / SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)
|
6GK5206-2RS00-5FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)
Siemens / SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)
|
6GK5206-2BS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)
Siemens / SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)
|
6GK5206-2BS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)
Siemens / SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)
|
6GK5206-2GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)
Siemens / SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)
|
6GK5206-2GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)
Siemens / SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)
|
6GK5206-2GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208 (6GK5208-0BA00-2AC2)
Siemens / SCALANCE XC208 (6GK5208-0BA00-2AC2)
|
6GK5208-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208EEC (6GK5208-0BA00-2FC2)
Siemens / SCALANCE XC208EEC (6GK5208-0BA00-2FC2)
|
6GK5208-0BA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G (6GK5208-0GA00-2AC2)
Siemens / SCALANCE XC208G (6GK5208-0GA00-2AC2)
|
6GK5208-0GA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)
Siemens / SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)
|
6GK5208-0GA00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)
Siemens / SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)
|
6GK5208-0GA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)
Siemens / SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)
|
6GK5208-0RA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)
Siemens / SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)
|
6GK5208-0RA00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216 (6GK5216-0BA00-2AC2)
Siemens / SCALANCE XC216 (6GK5216-0BA00-2AC2)
|
6GK5216-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)
Siemens / SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)
|
6GK5216-3RS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)
Siemens / SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)
|
6GK5216-3RS00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C (6GK5216-4BS00-2AC2)
Siemens / SCALANCE XC216-4C (6GK5216-4BS00-2AC2)
|
6GK5216-4BS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)
Siemens / SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)
|
6GK5216-4GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)
Siemens / SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)
|
6GK5216-4GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)
Siemens / SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)
|
6GK5216-4GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216EEC (6GK5216-0BA00-2FC2)
Siemens / SCALANCE XC216EEC (6GK5216-0BA00-2FC2)
|
6GK5216-0BA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224 (6GK5224-0BA00-2AC2)
Siemens / SCALANCE XC224 (6GK5224-0BA00-2AC2)
|
6GK5224-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)
Siemens / SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)
|
6GK5224-4GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)
Siemens / SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)
|
6GK5224-4GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)
Siemens / SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)
|
6GK5224-4GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204 (6GK5204-0BA00-2GF2)
Siemens / SCALANCE XF204 (6GK5204-0BA00-2GF2)
|
6GK5204-0BA00-2GF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)
Siemens / SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)
|
6GK5204-0BA00-2YF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)
Siemens / SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)
|
6GK5204-2AA00-2GF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)
Siemens / SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)
|
6GK5204-2AA00-2YF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-4C (6GK5408-4GP00-2AM2)
Siemens / SCALANCE XM408-4C (6GK5408-4GP00-2AM2)
|
6GK5408-4GP00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)
Siemens / SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)
|
6GK5408-4GQ00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-8C (6GK5408-8GS00-2AM2)
Siemens / SCALANCE XM408-8C (6GK5408-8GS00-2AM2)
|
6GK5408-8GS00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)
Siemens / SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)
|
6GK5408-8GR00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM416-4C (6GK5416-4GS00-2AM2)
Siemens / SCALANCE XM416-4C (6GK5416-4GS00-2AM2)
|
6GK5416-4GS00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)
Siemens / SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)
|
6GK5416-4GR00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208 (6GK5208-0HA00-2AS6)
Siemens / SCALANCE XP208 (6GK5208-0HA00-2AS6)
|
6GK5208-0HA00-2AS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)
Siemens / SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)
|
6GK5208-0HA00-2TS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208EEC (6GK5208-0HA00-2ES6)
Siemens / SCALANCE XP208EEC (6GK5208-0HA00-2ES6)
|
6GK5208-0HA00-2ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)
Siemens / SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)
|
6GK5208-0UA00-5ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (6GK5216-0HA00-2AS6)
Siemens / SCALANCE XP216 (6GK5216-0HA00-2AS6)
|
6GK5216-0HA00-2AS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)
Siemens / SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)
|
6GK5216-0HA00-2TS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216EEC (6GK5216-0HA00-2ES6)
Siemens / SCALANCE XP216EEC (6GK5216-0HA00-2ES6)
|
6GK5216-0HA00-2ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)
Siemens / SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)
|
6GK5216-0UA00-5ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)
Siemens / SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)
|
6GK5324-0BA00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)
Siemens / SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)
|
6GK5324-0BA00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)
Siemens / SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)
|
6GK5326-2QS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)
Siemens / SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)
|
6GK5326-2QS00-3RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)
Siemens / SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)
|
6GK5328-4FS00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)
Siemens / SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)
|
6GK5328-4FS00-2RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)
Siemens / SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)
|
6GK5328-4FS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)
Siemens / SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)
|
6GK5328-4FS00-3RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)
Siemens / SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)
|
6GK5328-4SS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)
Siemens / SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)
|
6GK5328-4SS00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)
Siemens / SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)
|
6GK5524-8GS00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)
Siemens / SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)
|
6GK5524-8GR00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)
Siemens / SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)
|
6GK5524-8GS00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)
Siemens / SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)
|
6GK5524-8GR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)
Siemens / SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)
|
6GK5524-8GS00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)
Siemens / SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)
|
6GK5524-8GR00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)
Siemens / SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)
|
6GK5526-8GS00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)
Siemens / SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)
|
6GK5526-8GR00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)
Siemens / SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)
|
6GK5526-8GS00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)
Siemens / SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)
|
6GK5526-8GR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)
Siemens / SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)
|
6GK5526-8GS00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)
Siemens / SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)
|
6GK5526-8GR00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (6GK5528-0AA00-2AR2)
Siemens / SCALANCE XR528-6M (6GK5528-0AA00-2AR2)
|
6GK5528-0AA00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)
Siemens / SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)
|
6GK5528-0AR00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)
Siemens / SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)
|
6GK5528-0AA00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)
Siemens / SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)
|
6GK5528-0AR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (6GK5552-0AA00-2AR2)
Siemens / SCALANCE XR552-12M (6GK5552-0AA00-2AR2)
|
6GK5552-0AA00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)
Siemens / SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)
|
6GK5552-0AR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)
Siemens / SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)
|
6GK5552-0AA00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)
Siemens / SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)
|
6GK5552-0AR00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)
Siemens / SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)
|
6AG1206-2BB00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)
Siemens / SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)
|
6AG1206-2BS00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)
Siemens / SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)
|
6AG1208-0BA00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)
Siemens / SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)
|
6AG1216-4BS00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
6GK6108-4AM00-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
6GK6108-4AM00-2DA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M804PB (6GK5804-0AP00-2AA2)
Siemens / SCALANCE M804PB (6GK5804-0AP00-2AA2)
|
6GK5804-0AP00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
Siemens / SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
|
6GK5812-1AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
Siemens / SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
|
6GK5812-1BA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
Siemens / SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
|
6GK5816-1AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
Siemens / SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
|
6GK5816-1BA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
Siemens / SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
|
6GK5826-2AB00-2AB2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-2 (6GK5874-2AA00-2AA2)
Siemens / SCALANCE M874-2 (6GK5874-2AA00-2AA2)
|
6GK5874-2AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-3 (6GK5874-3AA00-2AA2)
Siemens / SCALANCE M874-3 (6GK5874-3AA00-2AA2)
|
6GK5874-3AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-3 (6GK5876-3AA02-2BA2)
Siemens / SCALANCE M876-3 (6GK5876-3AA02-2BA2)
|
6GK5876-3AA02-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)
Siemens / SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)
|
6GK5876-3AA02-2EA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)
Siemens / SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)
|
6GK5876-4AA00-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)
Siemens / SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)
|
6GK5876-4AA00-2DA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)
Siemens / SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)
|
6GK5853-2EA00-2DA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)
Siemens / SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)
|
6GK5856-2EA00-3DA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)
Siemens / SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)
|
6GK5856-2EA00-3AA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)
Siemens / SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)
|
6GK5615-0AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC622-2C (6GK5622-2GS00-2AC2)
Siemens / SCALANCE SC622-2C (6GK5622-2GS00-2AC2)
|
6GK5622-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC626-2C (6GK5626-2GS00-2AC2)
Siemens / SCALANCE SC626-2C (6GK5626-2GS00-2AC2)
|
6GK5626-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC632-2C (6GK5632-2GS00-2AC2)
Siemens / SCALANCE SC632-2C (6GK5632-2GS00-2AC2)
|
6GK5632-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC636-2C (6GK5636-2GS00-2AC2)
Siemens / SCALANCE SC636-2C (6GK5636-2GS00-2AC2)
|
6GK5636-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC642-2C (6GK5642-2GS00-2AC2)
Siemens / SCALANCE SC642-2C (6GK5642-2GS00-2AC2)
|
6GK5642-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC646-2C (6GK5646-2GS00-2AC2)
Siemens / SCALANCE SC646-2C (6GK5646-2GS00-2AC2)
|
6GK5646-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)
Siemens / SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)
|
6GK5748-1GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)
Siemens / SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)
|
6GK5748-1GY01-0TA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)
Siemens / SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)
|
6GK5788-1GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)
Siemens / SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)
|
6GK5788-2GY01-0TA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)
Siemens / SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)
|
6GK5788-2GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)
Siemens / SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)
|
6GK5788-2HY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)
Siemens / SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)
|
6GK5763-1AL00-7DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)
Siemens / SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)
|
6GK5766-1GE00-7DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)
Siemens / SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)
|
6GK5766-1GE00-7DB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)
Siemens / SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)
|
6GK5766-1GE00-7TA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)
Siemens / SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)
|
6GK5766-1GE00-7TB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)
Siemens / SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)
|
6GK5763-1AL00-3AA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)
Siemens / SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)
|
6GK5763-1AL00-3DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)
Siemens / SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)
|
6GK5766-1GE00-3DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)
Siemens / SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)
|
6GK5766-1GE00-3DB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)
Siemens / SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)
|
6GK5205-3BB00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)
Siemens / SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)
|
6GK5205-3BB00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)
Siemens / SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)
|
6GK5205-3BD00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)
Siemens / SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)
|
6GK5205-3BD00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)
Siemens / SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)
|
6GK5205-3BF00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)
Siemens / SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)
|
6GK5205-3BF00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)
Siemens / SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)
|
6GK5208-0BA00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)
Siemens / SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)
|
6GK5208-0BA00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)
Siemens / SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)
|
6GK5213-3BD00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)
Siemens / SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)
|
6GK5213-3BD00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)
Siemens / SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)
|
6GK5213-3BB00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)
Siemens / SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)
|
6GK5213-3BB00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)
Siemens / SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)
|
6GK5213-3BF00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)
Siemens / SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)
|
6GK5213-3BF00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)
Siemens / SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)
|
6GK5216-0BA00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)
Siemens / SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)
|
6GK5216-0BA00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)
Siemens / SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)
|
6GK5206-2BD00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)
Siemens / SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)
|
6GK5206-2BB00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)
Siemens / SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)
|
6GK5206-2RS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)
Siemens / SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)
|
6GK5206-2RS00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)
Siemens / SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)
|
6GK5206-2RS00-5FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)
Siemens / SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)
|
6GK5206-2BS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)
Siemens / SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)
|
6GK5206-2BS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)
Siemens / SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)
|
6GK5206-2GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)
Siemens / SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)
|
6GK5206-2GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)
Siemens / SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)
|
6GK5206-2GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208 (6GK5208-0BA00-2AC2)
Siemens / SCALANCE XC208 (6GK5208-0BA00-2AC2)
|
6GK5208-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208EEC (6GK5208-0BA00-2FC2)
Siemens / SCALANCE XC208EEC (6GK5208-0BA00-2FC2)
|
6GK5208-0BA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G (6GK5208-0GA00-2AC2)
Siemens / SCALANCE XC208G (6GK5208-0GA00-2AC2)
|
6GK5208-0GA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)
Siemens / SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)
|
6GK5208-0GA00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)
Siemens / SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)
|
6GK5208-0GA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)
Siemens / SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)
|
6GK5208-0RA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)
Siemens / SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)
|
6GK5208-0RA00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216 (6GK5216-0BA00-2AC2)
Siemens / SCALANCE XC216 (6GK5216-0BA00-2AC2)
|
6GK5216-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)
Siemens / SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)
|
6GK5216-3RS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)
Siemens / SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)
|
6GK5216-3RS00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C (6GK5216-4BS00-2AC2)
Siemens / SCALANCE XC216-4C (6GK5216-4BS00-2AC2)
|
6GK5216-4BS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)
Siemens / SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)
|
6GK5216-4GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)
Siemens / SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)
|
6GK5216-4GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)
Siemens / SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)
|
6GK5216-4GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216EEC (6GK5216-0BA00-2FC2)
Siemens / SCALANCE XC216EEC (6GK5216-0BA00-2FC2)
|
6GK5216-0BA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224 (6GK5224-0BA00-2AC2)
Siemens / SCALANCE XC224 (6GK5224-0BA00-2AC2)
|
6GK5224-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)
Siemens / SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)
|
6GK5224-4GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)
Siemens / SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)
|
6GK5224-4GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)
Siemens / SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)
|
6GK5224-4GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204 (6GK5204-0BA00-2GF2)
Siemens / SCALANCE XF204 (6GK5204-0BA00-2GF2)
|
6GK5204-0BA00-2GF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)
Siemens / SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)
|
6GK5204-0BA00-2YF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)
Siemens / SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)
|
6GK5204-2AA00-2GF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)
Siemens / SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)
|
6GK5204-2AA00-2YF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-4C (6GK5408-4GP00-2AM2)
Siemens / SCALANCE XM408-4C (6GK5408-4GP00-2AM2)
|
6GK5408-4GP00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)
Siemens / SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)
|
6GK5408-4GQ00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-8C (6GK5408-8GS00-2AM2)
Siemens / SCALANCE XM408-8C (6GK5408-8GS00-2AM2)
|
6GK5408-8GS00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)
Siemens / SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)
|
6GK5408-8GR00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM416-4C (6GK5416-4GS00-2AM2)
Siemens / SCALANCE XM416-4C (6GK5416-4GS00-2AM2)
|
6GK5416-4GS00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)
Siemens / SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)
|
6GK5416-4GR00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208 (6GK5208-0HA00-2AS6)
Siemens / SCALANCE XP208 (6GK5208-0HA00-2AS6)
|
6GK5208-0HA00-2AS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)
Siemens / SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)
|
6GK5208-0HA00-2TS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208EEC (6GK5208-0HA00-2ES6)
Siemens / SCALANCE XP208EEC (6GK5208-0HA00-2ES6)
|
6GK5208-0HA00-2ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)
Siemens / SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)
|
6GK5208-0UA00-5ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (6GK5216-0HA00-2AS6)
Siemens / SCALANCE XP216 (6GK5216-0HA00-2AS6)
|
6GK5216-0HA00-2AS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)
Siemens / SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)
|
6GK5216-0HA00-2TS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216EEC (6GK5216-0HA00-2ES6)
Siemens / SCALANCE XP216EEC (6GK5216-0HA00-2ES6)
|
6GK5216-0HA00-2ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)
Siemens / SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)
|
6GK5216-0UA00-5ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)
Siemens / SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)
|
6GK5324-0BA00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)
Siemens / SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)
|
6GK5324-0BA00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)
Siemens / SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)
|
6GK5326-2QS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)
Siemens / SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)
|
6GK5326-2QS00-3RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)
Siemens / SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)
|
6GK5328-4FS00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)
Siemens / SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)
|
6GK5328-4FS00-2RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)
Siemens / SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)
|
6GK5328-4FS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)
Siemens / SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)
|
6GK5328-4FS00-3RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)
Siemens / SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)
|
6GK5328-4SS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)
Siemens / SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)
|
6GK5328-4SS00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)
Siemens / SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)
|
6GK5524-8GS00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)
Siemens / SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)
|
6GK5524-8GR00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)
Siemens / SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)
|
6GK5524-8GS00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)
Siemens / SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)
|
6GK5524-8GR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)
Siemens / SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)
|
6GK5524-8GS00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)
Siemens / SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)
|
6GK5524-8GR00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)
Siemens / SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)
|
6GK5526-8GS00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)
Siemens / SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)
|
6GK5526-8GR00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)
Siemens / SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)
|
6GK5526-8GS00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)
Siemens / SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)
|
6GK5526-8GR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)
Siemens / SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)
|
6GK5526-8GS00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)
Siemens / SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)
|
6GK5526-8GR00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (6GK5528-0AA00-2AR2)
Siemens / SCALANCE XR528-6M (6GK5528-0AA00-2AR2)
|
6GK5528-0AA00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)
Siemens / SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)
|
6GK5528-0AR00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)
Siemens / SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)
|
6GK5528-0AA00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)
Siemens / SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)
|
6GK5528-0AR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (6GK5552-0AA00-2AR2)
Siemens / SCALANCE XR552-12M (6GK5552-0AA00-2AR2)
|
6GK5552-0AA00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)
Siemens / SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)
|
6GK5552-0AR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)
Siemens / SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)
|
6GK5552-0AA00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)
Siemens / SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)
|
6GK5552-0AR00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)
Siemens / SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)
|
6AG1206-2BB00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)
Siemens / SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)
|
6AG1206-2BS00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)
Siemens / SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)
|
6AG1208-0BA00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)
Siemens / SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)
|
6AG1216-4BS00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
6GK6108-4AM00-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
6GK6108-4AM00-2DA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M804PB (6GK5804-0AP00-2AA2)
Siemens / SCALANCE M804PB (6GK5804-0AP00-2AA2)
|
6GK5804-0AP00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
Siemens / SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
|
6GK5812-1AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
Siemens / SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
|
6GK5812-1BA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
Siemens / SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
|
6GK5816-1AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
Siemens / SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
|
6GK5816-1BA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
Siemens / SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
|
6GK5826-2AB00-2AB2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-2 (6GK5874-2AA00-2AA2)
Siemens / SCALANCE M874-2 (6GK5874-2AA00-2AA2)
|
6GK5874-2AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-3 (6GK5874-3AA00-2AA2)
Siemens / SCALANCE M874-3 (6GK5874-3AA00-2AA2)
|
6GK5874-3AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-3 (6GK5876-3AA02-2BA2)
Siemens / SCALANCE M876-3 (6GK5876-3AA02-2BA2)
|
6GK5876-3AA02-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)
Siemens / SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)
|
6GK5876-3AA02-2EA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)
Siemens / SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)
|
6GK5876-4AA00-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)
Siemens / SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)
|
6GK5876-4AA00-2DA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)
Siemens / SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)
|
6GK5853-2EA00-2DA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)
Siemens / SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)
|
6GK5856-2EA00-3DA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)
Siemens / SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)
|
6GK5856-2EA00-3AA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)
Siemens / SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)
|
6GK5615-0AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC622-2C (6GK5622-2GS00-2AC2)
Siemens / SCALANCE SC622-2C (6GK5622-2GS00-2AC2)
|
6GK5622-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC626-2C (6GK5626-2GS00-2AC2)
Siemens / SCALANCE SC626-2C (6GK5626-2GS00-2AC2)
|
6GK5626-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC632-2C (6GK5632-2GS00-2AC2)
Siemens / SCALANCE SC632-2C (6GK5632-2GS00-2AC2)
|
6GK5632-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE SC636-2C (6GK5636-2GS00-2AC2)
Siemens / SCALANCE SC636-2C (6GK5636-2GS00-2AC2)
|
6GK5636-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE SC642-2C (6GK5642-2GS00-2AC2)
Siemens / SCALANCE SC642-2C (6GK5642-2GS00-2AC2)
|
6GK5642-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE SC646-2C (6GK5646-2GS00-2AC2)
Siemens / SCALANCE SC646-2C (6GK5646-2GS00-2AC2)
|
6GK5646-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)
Siemens / SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)
|
6GK5748-1GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)
Siemens / SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)
|
6GK5748-1GY01-0TA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)
Siemens / SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)
|
6GK5788-1GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)
Siemens / SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)
|
6GK5788-2GY01-0TA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)
Siemens / SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)
|
6GK5788-2GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)
Siemens / SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)
|
6GK5788-2HY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)
Siemens / SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)
|
6GK5763-1AL00-7DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)
Siemens / SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)
|
6GK5766-1GE00-7DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)
Siemens / SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)
|
6GK5766-1GE00-7DB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)
Siemens / SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)
|
6GK5766-1GE00-7TA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)
Siemens / SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)
|
6GK5766-1GE00-7TB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)
Siemens / SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)
|
6GK5763-1AL00-3AA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)
Siemens / SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)
|
6GK5763-1AL00-3DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)
Siemens / SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)
|
6GK5766-1GE00-3DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)
Siemens / SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)
|
6GK5766-1GE00-3DB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)
Siemens / SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)
|
6GK5205-3BB00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)
Siemens / SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)
|
6GK5205-3BB00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)
Siemens / SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)
|
6GK5205-3BD00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)
Siemens / SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)
|
6GK5205-3BD00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)
Siemens / SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)
|
6GK5205-3BF00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)
Siemens / SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)
|
6GK5205-3BF00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)
Siemens / SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)
|
6GK5208-0BA00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)
Siemens / SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)
|
6GK5208-0BA00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)
Siemens / SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)
|
6GK5213-3BD00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)
Siemens / SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)
|
6GK5213-3BD00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)
Siemens / SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)
|
6GK5213-3BB00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)
Siemens / SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)
|
6GK5213-3BB00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)
Siemens / SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)
|
6GK5213-3BF00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)
Siemens / SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)
|
6GK5213-3BF00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)
Siemens / SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)
|
6GK5216-0BA00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)
Siemens / SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)
|
6GK5216-0BA00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)
Siemens / SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)
|
6GK5206-2BD00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)
Siemens / SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)
|
6GK5206-2BB00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)
Siemens / SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)
|
6GK5206-2RS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)
Siemens / SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)
|
6GK5206-2RS00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)
Siemens / SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)
|
6GK5206-2RS00-5FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)
Siemens / SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)
|
6GK5206-2BS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)
Siemens / SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)
|
6GK5206-2BS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)
Siemens / SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)
|
6GK5206-2GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)
Siemens / SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)
|
6GK5206-2GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)
Siemens / SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)
|
6GK5206-2GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208 (6GK5208-0BA00-2AC2)
Siemens / SCALANCE XC208 (6GK5208-0BA00-2AC2)
|
6GK5208-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208EEC (6GK5208-0BA00-2FC2)
Siemens / SCALANCE XC208EEC (6GK5208-0BA00-2FC2)
|
6GK5208-0BA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G (6GK5208-0GA00-2AC2)
Siemens / SCALANCE XC208G (6GK5208-0GA00-2AC2)
|
6GK5208-0GA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)
Siemens / SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)
|
6GK5208-0GA00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)
Siemens / SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)
|
6GK5208-0GA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)
Siemens / SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)
|
6GK5208-0RA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)
Siemens / SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)
|
6GK5208-0RA00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216 (6GK5216-0BA00-2AC2)
Siemens / SCALANCE XC216 (6GK5216-0BA00-2AC2)
|
6GK5216-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)
Siemens / SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)
|
6GK5216-3RS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)
Siemens / SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)
|
6GK5216-3RS00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C (6GK5216-4BS00-2AC2)
Siemens / SCALANCE XC216-4C (6GK5216-4BS00-2AC2)
|
6GK5216-4BS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)
Siemens / SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)
|
6GK5216-4GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)
Siemens / SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)
|
6GK5216-4GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)
Siemens / SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)
|
6GK5216-4GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216EEC (6GK5216-0BA00-2FC2)
Siemens / SCALANCE XC216EEC (6GK5216-0BA00-2FC2)
|
6GK5216-0BA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224 (6GK5224-0BA00-2AC2)
Siemens / SCALANCE XC224 (6GK5224-0BA00-2AC2)
|
6GK5224-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)
Siemens / SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)
|
6GK5224-4GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)
Siemens / SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)
|
6GK5224-4GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)
Siemens / SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)
|
6GK5224-4GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204 (6GK5204-0BA00-2GF2)
Siemens / SCALANCE XF204 (6GK5204-0BA00-2GF2)
|
6GK5204-0BA00-2GF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)
Siemens / SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)
|
6GK5204-0BA00-2YF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)
Siemens / SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)
|
6GK5204-2AA00-2GF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)
Siemens / SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)
|
6GK5204-2AA00-2YF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-4C (6GK5408-4GP00-2AM2)
Siemens / SCALANCE XM408-4C (6GK5408-4GP00-2AM2)
|
6GK5408-4GP00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)
Siemens / SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)
|
6GK5408-4GQ00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-8C (6GK5408-8GS00-2AM2)
Siemens / SCALANCE XM408-8C (6GK5408-8GS00-2AM2)
|
6GK5408-8GS00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)
Siemens / SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)
|
6GK5408-8GR00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM416-4C (6GK5416-4GS00-2AM2)
Siemens / SCALANCE XM416-4C (6GK5416-4GS00-2AM2)
|
6GK5416-4GS00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)
Siemens / SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)
|
6GK5416-4GR00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208 (6GK5208-0HA00-2AS6)
Siemens / SCALANCE XP208 (6GK5208-0HA00-2AS6)
|
6GK5208-0HA00-2AS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)
Siemens / SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)
|
6GK5208-0HA00-2TS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208EEC (6GK5208-0HA00-2ES6)
Siemens / SCALANCE XP208EEC (6GK5208-0HA00-2ES6)
|
6GK5208-0HA00-2ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)
Siemens / SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)
|
6GK5208-0UA00-5ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (6GK5216-0HA00-2AS6)
Siemens / SCALANCE XP216 (6GK5216-0HA00-2AS6)
|
6GK5216-0HA00-2AS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)
Siemens / SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)
|
6GK5216-0HA00-2TS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216EEC (6GK5216-0HA00-2ES6)
Siemens / SCALANCE XP216EEC (6GK5216-0HA00-2ES6)
|
6GK5216-0HA00-2ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)
Siemens / SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)
|
6GK5216-0UA00-5ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)
Siemens / SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)
|
6GK5324-0BA00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)
Siemens / SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)
|
6GK5324-0BA00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)
Siemens / SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)
|
6GK5326-2QS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)
Siemens / SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)
|
6GK5326-2QS00-3RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)
Siemens / SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)
|
6GK5328-4FS00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)
Siemens / SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)
|
6GK5328-4FS00-2RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)
Siemens / SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)
|
6GK5328-4FS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)
Siemens / SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)
|
6GK5328-4FS00-3RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)
Siemens / SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)
|
6GK5328-4SS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)
Siemens / SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)
|
6GK5328-4SS00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)
Siemens / SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)
|
6GK5524-8GS00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)
Siemens / SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)
|
6GK5524-8GR00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)
Siemens / SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)
|
6GK5524-8GS00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)
Siemens / SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)
|
6GK5524-8GR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)
Siemens / SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)
|
6GK5524-8GS00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)
Siemens / SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)
|
6GK5524-8GR00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)
Siemens / SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)
|
6GK5526-8GS00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)
Siemens / SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)
|
6GK5526-8GR00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)
Siemens / SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)
|
6GK5526-8GS00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)
Siemens / SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)
|
6GK5526-8GR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)
Siemens / SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)
|
6GK5526-8GS00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)
Siemens / SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)
|
6GK5526-8GR00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (6GK5528-0AA00-2AR2)
Siemens / SCALANCE XR528-6M (6GK5528-0AA00-2AR2)
|
6GK5528-0AA00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)
Siemens / SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)
|
6GK5528-0AR00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)
Siemens / SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)
|
6GK5528-0AA00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)
Siemens / SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)
|
6GK5528-0AR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (6GK5552-0AA00-2AR2)
Siemens / SCALANCE XR552-12M (6GK5552-0AA00-2AR2)
|
6GK5552-0AA00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)
Siemens / SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)
|
6GK5552-0AR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)
Siemens / SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)
|
6GK5552-0AA00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)
Siemens / SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)
|
6GK5552-0AR00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)
Siemens / SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)
|
6AG1206-2BB00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)
Siemens / SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)
|
6AG1206-2BS00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)
Siemens / SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)
|
6AG1208-0BA00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)
Siemens / SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)
|
6AG1216-4BS00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reported these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "SCALANCE devices contain multiple vulnerabilities in MSPS based product lines that could allow authenticated remote attackers to execute custom code or create a XSS situation, as well as unauthenticated remote attackers to create a denial of service condition.\n\nSiemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Siemens ProductCERT SSA-710008 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-710008: Multiple Web Vulnerabilities in SCALANCE Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-710008.json"
},
{
"category": "self",
"summary": "SSA-710008: Multiple Web Vulnerabilities in SCALANCE Products - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-223-07 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-223-07.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-223-07 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-07"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Siemens SCALANCE",
"tracking": {
"current_release_date": "2026-04-16T06:00:00.000000Z",
"generator": {
"date": "2026-04-15T16:33:43.871628Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.5.0"
}
},
"id": "ICSA-22-223-07",
"initial_release_date": "2022-08-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2022-08-09T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2022-09-13T00:00:00.000000Z",
"legacy_version": "Additional Release 1",
"number": "2",
"summary": "Added fix for SCALANCE M-800, SCALANCE MUM-800 and RUGGEDCOM RM1224 families, as well as for SCALANCE S615 families; All affected product families were expanded"
},
{
"date": "2023-01-10T00:00:00.000000Z",
"legacy_version": "Additional Release 2",
"number": "3",
"summary": "Added fix for SCALANCE W-700 IEEE 802.11ax product family"
},
{
"date": "2023-04-11T00:00:00.000000Z",
"legacy_version": "Additional Release 3",
"number": "4",
"summary": "Added fix for SCALANCE XM-400/XR-500 family and for SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG family"
},
{
"date": "2023-10-10T00:00:00.000000Z",
"legacy_version": "Additional Release 4",
"number": "5",
"summary": "Added that SCALANCE SC-600 family was also affected by CVE-2022-36324"
},
{
"date": "2026-04-14T00:00:00.000000Z",
"legacy_version": "Additional Release 5",
"number": "6",
"summary": "Added fix for SCALANCE W-700 IEEE 802.11n family"
},
{
"date": "2026-04-16T06:00:00.000000Z",
"legacy_version": "Latest Updated CISA Republication",
"number": "7",
"summary": "CISA Republication update based on Siemens ProductCERT SSA-710008 advisory"
}
],
"status": "final",
"version": "7"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)",
"product_id": "CSAFPID-0001",
"product_identification_helper": {
"model_numbers": [
"6GK6108-4AM00-2BA2"
]
}
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)",
"product_id": "CSAFPID-0002",
"product_identification_helper": {
"model_numbers": [
"6GK6108-4AM00-2DA2"
]
}
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)",
"product_id": "CSAFPID-0003",
"product_identification_helper": {
"model_numbers": [
"6GK5804-0AP00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)",
"product_id": "CSAFPID-0004",
"product_identification_helper": {
"model_numbers": [
"6GK5812-1AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)",
"product_id": "CSAFPID-0005",
"product_identification_helper": {
"model_numbers": [
"6GK5812-1BA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)",
"product_id": "CSAFPID-0006",
"product_identification_helper": {
"model_numbers": [
"6GK5816-1AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)",
"product_id": "CSAFPID-0007",
"product_identification_helper": {
"model_numbers": [
"6GK5816-1BA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)",
"product_id": "CSAFPID-0008",
"product_identification_helper": {
"model_numbers": [
"6GK5826-2AB00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)",
"product_id": "CSAFPID-0009",
"product_identification_helper": {
"model_numbers": [
"6GK5874-2AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)",
"product_id": "CSAFPID-0010",
"product_identification_helper": {
"model_numbers": [
"6GK5874-3AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M876-3 (6GK5876-3AA02-2BA2)",
"product_id": "CSAFPID-0011",
"product_identification_helper": {
"model_numbers": [
"6GK5876-3AA02-2BA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M876-3 (6GK5876-3AA02-2BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)",
"product_id": "CSAFPID-0012",
"product_identification_helper": {
"model_numbers": [
"6GK5876-3AA02-2EA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)",
"product_id": "CSAFPID-0013",
"product_identification_helper": {
"model_numbers": [
"6GK5876-4AA00-2BA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)",
"product_id": "CSAFPID-0014",
"product_identification_helper": {
"model_numbers": [
"6GK5876-4AA00-2DA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)",
"product_id": "CSAFPID-0015",
"product_identification_helper": {
"model_numbers": [
"6GK5853-2EA00-2DA1"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)",
"product_id": "CSAFPID-0016",
"product_identification_helper": {
"model_numbers": [
"6GK5856-2EA00-3DA1"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)",
"product_id": "CSAFPID-0017",
"product_identification_helper": {
"model_numbers": [
"6GK5856-2EA00-3AA1"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)",
"product_id": "CSAFPID-0018",
"product_identification_helper": {
"model_numbers": [
"6GK5615-0AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.3.1",
"product": {
"name": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2)",
"product_id": "CSAFPID-0019",
"product_identification_helper": {
"model_numbers": [
"6GK5622-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.3.1",
"product": {
"name": "SCALANCE SC626-2C (6GK5626-2GS00-2AC2)",
"product_id": "CSAFPID-0020",
"product_identification_helper": {
"model_numbers": [
"6GK5626-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC626-2C (6GK5626-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.3.1",
"product": {
"name": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2)",
"product_id": "CSAFPID-0021",
"product_identification_helper": {
"model_numbers": [
"6GK5632-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.3.1",
"product": {
"name": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2)",
"product_id": "CSAFPID-0022",
"product_identification_helper": {
"model_numbers": [
"6GK5636-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.3.1",
"product": {
"name": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2)",
"product_id": "CSAFPID-0023",
"product_identification_helper": {
"model_numbers": [
"6GK5642-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.3.1",
"product": {
"name": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2)",
"product_id": "CSAFPID-0024",
"product_identification_helper": {
"model_numbers": [
"6GK5646-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)",
"product_id": "CSAFPID-0025",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GY01-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)",
"product_id": "CSAFPID-0026",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GY01-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)",
"product_id": "CSAFPID-0027",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1GY01-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)",
"product_id": "CSAFPID-0028",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GY01-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)",
"product_id": "CSAFPID-0029",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GY01-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)",
"product_id": "CSAFPID-0030",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2HY01-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)",
"product_id": "CSAFPID-0031",
"product_identification_helper": {
"model_numbers": [
"6GK5721-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)",
"product_id": "CSAFPID-0032",
"product_identification_helper": {
"model_numbers": [
"6GK5721-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)",
"product_id": "CSAFPID-0033",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)",
"product_id": "CSAFPID-0034",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)",
"product_id": "CSAFPID-0035",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)",
"product_id": "CSAFPID-0036",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)",
"product_id": "CSAFPID-0037",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)",
"product_id": "CSAFPID-0038",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)",
"product_id": "CSAFPID-0039",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AB6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)",
"product_id": "CSAFPID-0040",
"product_identification_helper": {
"model_numbers": [
"6GK5738-1GY00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)",
"product_id": "CSAFPID-0041",
"product_identification_helper": {
"model_numbers": [
"6GK5738-1GY00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)",
"product_id": "CSAFPID-0042",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)",
"product_id": "CSAFPID-0043",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)",
"product_id": "CSAFPID-0044",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)",
"product_id": "CSAFPID-0045",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)",
"product_id": "CSAFPID-0046",
"product_identification_helper": {
"model_numbers": [
"6GK5761-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)",
"product_id": "CSAFPID-0047",
"product_identification_helper": {
"model_numbers": [
"6GK5761-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)",
"product_id": "CSAFPID-0048",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FY00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)",
"product_id": "CSAFPID-0049",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FY00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)",
"product_id": "CSAFPID-0050",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)",
"product_id": "CSAFPID-0051",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)",
"product_id": "CSAFPID-0052",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)",
"product_id": "CSAFPID-0053",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)",
"product_id": "CSAFPID-0054",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AB6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)",
"product_id": "CSAFPID-0055",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)",
"product_id": "CSAFPID-0056",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)",
"product_id": "CSAFPID-0057",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)",
"product_id": "CSAFPID-0058",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)",
"product_id": "CSAFPID-0059",
"product_identification_helper": {
"model_numbers": [
"6GK5786-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)",
"product_id": "CSAFPID-0060",
"product_identification_helper": {
"model_numbers": [
"6GK5786-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)",
"product_id": "CSAFPID-0061",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)",
"product_id": "CSAFPID-0062",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)",
"product_id": "CSAFPID-0063",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)",
"product_id": "CSAFPID-0064",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FE00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)",
"product_id": "CSAFPID-0065",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FE00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)",
"product_id": "CSAFPID-0066",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2HC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)",
"product_id": "CSAFPID-0067",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2HC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)",
"product_id": "CSAFPID-0068",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)",
"product_id": "CSAFPID-0069",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)",
"product_id": "CSAFPID-0070",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)",
"product_id": "CSAFPID-0071",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)",
"product_id": "CSAFPID-0072",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)",
"product_id": "CSAFPID-0073",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)",
"product_id": "CSAFPID-0074",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)",
"product_id": "CSAFPID-0075",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)",
"product_id": "CSAFPID-0076",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)",
"product_id": "CSAFPID-0077",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)",
"product_id": "CSAFPID-0078",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)",
"product_id": "CSAFPID-0079",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)",
"product_id": "CSAFPID-0080",
"product_identification_helper": {
"model_numbers": [
"6GK5763-1AL00-7DA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)",
"product_id": "CSAFPID-0081",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-7DA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)",
"product_id": "CSAFPID-0082",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-7DB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)",
"product_id": "CSAFPID-0083",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-7TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)",
"product_id": "CSAFPID-0084",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-7TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)",
"product_id": "CSAFPID-0085",
"product_identification_helper": {
"model_numbers": [
"6GK5763-1AL00-3AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)",
"product_id": "CSAFPID-0086",
"product_identification_helper": {
"model_numbers": [
"6GK5763-1AL00-3DA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)",
"product_id": "CSAFPID-0087",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-3DA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)",
"product_id": "CSAFPID-0088",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-3DB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)",
"product_id": "CSAFPID-0089",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BB00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)",
"product_id": "CSAFPID-0090",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BB00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)",
"product_id": "CSAFPID-0091",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BD00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)",
"product_id": "CSAFPID-0092",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BD00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)",
"product_id": "CSAFPID-0093",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BF00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)",
"product_id": "CSAFPID-0094",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BF00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)",
"product_id": "CSAFPID-0095",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)",
"product_id": "CSAFPID-0096",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)",
"product_id": "CSAFPID-0097",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BD00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)",
"product_id": "CSAFPID-0098",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BD00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)",
"product_id": "CSAFPID-0099",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BB00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)",
"product_id": "CSAFPID-0100",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BB00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)",
"product_id": "CSAFPID-0101",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BF00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)",
"product_id": "CSAFPID-0102",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BF00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)",
"product_id": "CSAFPID-0103",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0BA00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)",
"product_id": "CSAFPID-0104",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0BA00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)",
"product_id": "CSAFPID-0105",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BD00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)",
"product_id": "CSAFPID-0106",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BB00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)",
"product_id": "CSAFPID-0107",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2RS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)",
"product_id": "CSAFPID-0108",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2RS00-5AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)",
"product_id": "CSAFPID-0109",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2RS00-5FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)",
"product_id": "CSAFPID-0110",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)",
"product_id": "CSAFPID-0111",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BS00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)",
"product_id": "CSAFPID-0112",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)",
"product_id": "CSAFPID-0113",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2GS00-2TC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)",
"product_id": "CSAFPID-0114",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2GS00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC208 (6GK5208-0BA00-2AC2)",
"product_id": "CSAFPID-0115",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208 (6GK5208-0BA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC208EEC (6GK5208-0BA00-2FC2)",
"product_id": "CSAFPID-0116",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208EEC (6GK5208-0BA00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC208G (6GK5208-0GA00-2AC2)",
"product_id": "CSAFPID-0117",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0GA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G (6GK5208-0GA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)",
"product_id": "CSAFPID-0118",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0GA00-2TC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)",
"product_id": "CSAFPID-0119",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0GA00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)",
"product_id": "CSAFPID-0120",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0RA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)",
"product_id": "CSAFPID-0121",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0RA00-5AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216 (6GK5216-0BA00-2AC2)",
"product_id": "CSAFPID-0122",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0BA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216 (6GK5216-0BA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)",
"product_id": "CSAFPID-0123",
"product_identification_helper": {
"model_numbers": [
"6GK5216-3RS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)",
"product_id": "CSAFPID-0124",
"product_identification_helper": {
"model_numbers": [
"6GK5216-3RS00-5AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216-4C (6GK5216-4BS00-2AC2)",
"product_id": "CSAFPID-0125",
"product_identification_helper": {
"model_numbers": [
"6GK5216-4BS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-4C (6GK5216-4BS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)",
"product_id": "CSAFPID-0126",
"product_identification_helper": {
"model_numbers": [
"6GK5216-4GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)",
"product_id": "CSAFPID-0127",
"product_identification_helper": {
"model_numbers": [
"6GK5216-4GS00-2TC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)",
"product_id": "CSAFPID-0128",
"product_identification_helper": {
"model_numbers": [
"6GK5216-4GS00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216EEC (6GK5216-0BA00-2FC2)",
"product_id": "CSAFPID-0129",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0BA00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216EEC (6GK5216-0BA00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC224 (6GK5224-0BA00-2AC2)",
"product_id": "CSAFPID-0130",
"product_identification_helper": {
"model_numbers": [
"6GK5224-0BA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC224 (6GK5224-0BA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)",
"product_id": "CSAFPID-0131",
"product_identification_helper": {
"model_numbers": [
"6GK5224-4GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)",
"product_id": "CSAFPID-0132",
"product_identification_helper": {
"model_numbers": [
"6GK5224-4GS00-2TC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)",
"product_id": "CSAFPID-0133",
"product_identification_helper": {
"model_numbers": [
"6GK5224-4GS00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XF204 (6GK5204-0BA00-2GF2)",
"product_id": "CSAFPID-0134",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2GF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204 (6GK5204-0BA00-2GF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)",
"product_id": "CSAFPID-0135",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2YF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)",
"product_id": "CSAFPID-0136",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2AA00-2GF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)",
"product_id": "CSAFPID-0137",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2AA00-2YF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XM408-4C (6GK5408-4GP00-2AM2)",
"product_id": "CSAFPID-0138",
"product_identification_helper": {
"model_numbers": [
"6GK5408-4GP00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM408-4C (6GK5408-4GP00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)",
"product_id": "CSAFPID-0139",
"product_identification_helper": {
"model_numbers": [
"6GK5408-4GQ00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XM408-8C (6GK5408-8GS00-2AM2)",
"product_id": "CSAFPID-0140",
"product_identification_helper": {
"model_numbers": [
"6GK5408-8GS00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM408-8C (6GK5408-8GS00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)",
"product_id": "CSAFPID-0141",
"product_identification_helper": {
"model_numbers": [
"6GK5408-8GR00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XM416-4C (6GK5416-4GS00-2AM2)",
"product_id": "CSAFPID-0142",
"product_identification_helper": {
"model_numbers": [
"6GK5416-4GS00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM416-4C (6GK5416-4GS00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)",
"product_id": "CSAFPID-0143",
"product_identification_helper": {
"model_numbers": [
"6GK5416-4GR00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP208 (6GK5208-0HA00-2AS6)",
"product_id": "CSAFPID-0144",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0HA00-2AS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208 (6GK5208-0HA00-2AS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)",
"product_id": "CSAFPID-0145",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0HA00-2TS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP208EEC (6GK5208-0HA00-2ES6)",
"product_id": "CSAFPID-0146",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0HA00-2ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208EEC (6GK5208-0HA00-2ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)",
"product_id": "CSAFPID-0147",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0UA00-5ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP216 (6GK5216-0HA00-2AS6)",
"product_id": "CSAFPID-0148",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0HA00-2AS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216 (6GK5216-0HA00-2AS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)",
"product_id": "CSAFPID-0149",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0HA00-2TS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP216EEC (6GK5216-0HA00-2ES6)",
"product_id": "CSAFPID-0150",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0HA00-2ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216EEC (6GK5216-0HA00-2ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)",
"product_id": "CSAFPID-0151",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0UA00-5ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)",
"product_id": "CSAFPID-0152",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0BA00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)",
"product_id": "CSAFPID-0153",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0BA00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)",
"product_id": "CSAFPID-0154",
"product_identification_helper": {
"model_numbers": [
"6GK5326-2QS00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)",
"product_id": "CSAFPID-0155",
"product_identification_helper": {
"model_numbers": [
"6GK5326-2QS00-3RR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)",
"product_id": "CSAFPID-0156",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4FS00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)",
"product_id": "CSAFPID-0157",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4FS00-2RR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)",
"product_id": "CSAFPID-0158",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4FS00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)",
"product_id": "CSAFPID-0159",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4FS00-3RR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)",
"product_id": "CSAFPID-0160",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4SS00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)",
"product_id": "CSAFPID-0161",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4SS00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)",
"product_id": "CSAFPID-0162",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GS00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)",
"product_id": "CSAFPID-0163",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GR00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)",
"product_id": "CSAFPID-0164",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GS00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)",
"product_id": "CSAFPID-0165",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GR00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)",
"product_id": "CSAFPID-0166",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GS00-4AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)",
"product_id": "CSAFPID-0167",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GR00-4AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)",
"product_id": "CSAFPID-0168",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GS00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)",
"product_id": "CSAFPID-0169",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GR00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)",
"product_id": "CSAFPID-0170",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GS00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)",
"product_id": "CSAFPID-0171",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GR00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)",
"product_id": "CSAFPID-0172",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GS00-4AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)",
"product_id": "CSAFPID-0173",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GR00-4AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR528-6M (6GK5528-0AA00-2AR2)",
"product_id": "CSAFPID-0174",
"product_identification_helper": {
"model_numbers": [
"6GK5528-0AA00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR528-6M (6GK5528-0AA00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)",
"product_id": "CSAFPID-0175",
"product_identification_helper": {
"model_numbers": [
"6GK5528-0AR00-2HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)",
"product_id": "CSAFPID-0176",
"product_identification_helper": {
"model_numbers": [
"6GK5528-0AA00-2HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)",
"product_id": "CSAFPID-0177",
"product_identification_helper": {
"model_numbers": [
"6GK5528-0AR00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR552-12M (6GK5552-0AA00-2AR2)",
"product_id": "CSAFPID-0178",
"product_identification_helper": {
"model_numbers": [
"6GK5552-0AA00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR552-12M (6GK5552-0AA00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)",
"product_id": "CSAFPID-0179",
"product_identification_helper": {
"model_numbers": [
"6GK5552-0AR00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)",
"product_id": "CSAFPID-0180",
"product_identification_helper": {
"model_numbers": [
"6GK5552-0AA00-2HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)",
"product_id": "CSAFPID-0181",
"product_identification_helper": {
"model_numbers": [
"6GK5552-0AR00-2HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)",
"product_id": "CSAFPID-0182",
"product_identification_helper": {
"model_numbers": [
"6AG1206-2BB00-7AC2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)",
"product_id": "CSAFPID-0183",
"product_identification_helper": {
"model_numbers": [
"6AG1206-2BS00-7AC2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)",
"product_id": "CSAFPID-0184",
"product_identification_helper": {
"model_numbers": [
"6AG1208-0BA00-7AC2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)",
"product_id": "CSAFPID-0185",
"product_identification_helper": {
"model_numbers": [
"6AG1216-4BS00-7AC2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-36323",
"cwe": {
"id": "CWE-74",
"name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36323"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/74.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Apply the principle of least privileges for accounts configured on the affected devices",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
]
},
{
"category": "mitigation",
"details": "Restrict network access in affected system(s) to ports 80/TCP and 443/TCP to trusted IP addresses and personal only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.0.0 or later version",
"product_ids": [
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/"
},
{
"category": "vendor_fix",
"details": "Update to V2.3.1 or later version",
"product_ids": [
"CSAFPID-0019",
"CSAFPID-0020"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109810992/"
},
{
"category": "vendor_fix",
"details": "Update to V4.4 or later version",
"product_ids": [
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817768/"
},
{
"category": "vendor_fix",
"details": "Update to V6.6 or later version",
"product_ids": [
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818003/"
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
},
{
"category": "vendor_fix",
"details": "Update to V7.1.2 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109813051/"
},
{
"category": "vendor_fix",
"details": "Update to V2.3.1 or later version",
"product_ids": [
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
]
}
],
"title": "CVE-2022-36323"
},
{
"cve": "CVE-2022-36324",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36324"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/770.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Apply the principle of least privileges for accounts configured on the affected devices",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
]
},
{
"category": "mitigation",
"details": "Restrict network access in affected system(s) to ports 80/TCP and 443/TCP to trusted IP addresses and personal only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.0.0 or later version",
"product_ids": [
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/"
},
{
"category": "vendor_fix",
"details": "Update to V2.3.1 or later version",
"product_ids": [
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109810992/"
},
{
"category": "vendor_fix",
"details": "Update to V4.4 or later version",
"product_ids": [
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817768/"
},
{
"category": "vendor_fix",
"details": "Update to V6.6 or later version",
"product_ids": [
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818003/"
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
},
{
"category": "vendor_fix",
"details": "Update to V7.1.2 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109813051/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
]
}
],
"title": "CVE-2022-36324"
},
{
"cve": "CVE-2022-36325",
"cwe": {
"id": "CWE-80",
"name": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36325"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/80.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Apply the principle of least privileges for accounts configured on the affected devices",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
]
},
{
"category": "mitigation",
"details": "Restrict network access in affected system(s) to ports 80/TCP and 443/TCP to trusted IP addresses and personal only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.0.0 or later version",
"product_ids": [
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/"
},
{
"category": "vendor_fix",
"details": "Update to V2.3.1 or later version",
"product_ids": [
"CSAFPID-0019",
"CSAFPID-0020"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109810992/"
},
{
"category": "vendor_fix",
"details": "Update to V4.4 or later version",
"product_ids": [
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817768/"
},
{
"category": "vendor_fix",
"details": "Update to V6.6 or later version",
"product_ids": [
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818003/"
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
},
{
"category": "vendor_fix",
"details": "Update to V7.1.2 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109813051/"
},
{
"category": "vendor_fix",
"details": "Update to V2.3.1 or later version",
"product_ids": [
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082",
"CSAFPID-0083",
"CSAFPID-0084",
"CSAFPID-0085",
"CSAFPID-0086",
"CSAFPID-0087",
"CSAFPID-0088",
"CSAFPID-0089",
"CSAFPID-0090",
"CSAFPID-0091",
"CSAFPID-0092",
"CSAFPID-0093",
"CSAFPID-0094",
"CSAFPID-0095",
"CSAFPID-0096",
"CSAFPID-0097",
"CSAFPID-0098",
"CSAFPID-0099",
"CSAFPID-0100",
"CSAFPID-0101",
"CSAFPID-0102",
"CSAFPID-0103",
"CSAFPID-0104",
"CSAFPID-0105",
"CSAFPID-0106",
"CSAFPID-0107",
"CSAFPID-0108",
"CSAFPID-0109",
"CSAFPID-0110",
"CSAFPID-0111",
"CSAFPID-0112",
"CSAFPID-0113",
"CSAFPID-0114",
"CSAFPID-0115",
"CSAFPID-0116",
"CSAFPID-0117",
"CSAFPID-0118",
"CSAFPID-0119",
"CSAFPID-0120",
"CSAFPID-0121",
"CSAFPID-0122",
"CSAFPID-0123",
"CSAFPID-0124",
"CSAFPID-0125",
"CSAFPID-0126",
"CSAFPID-0127",
"CSAFPID-0128",
"CSAFPID-0129",
"CSAFPID-0130",
"CSAFPID-0131",
"CSAFPID-0132",
"CSAFPID-0133",
"CSAFPID-0134",
"CSAFPID-0135",
"CSAFPID-0136",
"CSAFPID-0137",
"CSAFPID-0138",
"CSAFPID-0139",
"CSAFPID-0140",
"CSAFPID-0141",
"CSAFPID-0142",
"CSAFPID-0143",
"CSAFPID-0144",
"CSAFPID-0145",
"CSAFPID-0146",
"CSAFPID-0147",
"CSAFPID-0148",
"CSAFPID-0149",
"CSAFPID-0150",
"CSAFPID-0151",
"CSAFPID-0152",
"CSAFPID-0153",
"CSAFPID-0154",
"CSAFPID-0155",
"CSAFPID-0156",
"CSAFPID-0157",
"CSAFPID-0158",
"CSAFPID-0159",
"CSAFPID-0160",
"CSAFPID-0161",
"CSAFPID-0162",
"CSAFPID-0163",
"CSAFPID-0164",
"CSAFPID-0165",
"CSAFPID-0166",
"CSAFPID-0167",
"CSAFPID-0168",
"CSAFPID-0169",
"CSAFPID-0170",
"CSAFPID-0171",
"CSAFPID-0172",
"CSAFPID-0173",
"CSAFPID-0174",
"CSAFPID-0175",
"CSAFPID-0176",
"CSAFPID-0177",
"CSAFPID-0178",
"CSAFPID-0179",
"CSAFPID-0180",
"CSAFPID-0181",
"CSAFPID-0182",
"CSAFPID-0183",
"CSAFPID-0184",
"CSAFPID-0185"
]
}
],
"title": "CVE-2022-36325"
}
]
}
ICSA-26-111-07
Vulnerability from csaf_cisa - Published: 2026-04-14 00:00 - Updated: 2026-04-21 06:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reported these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "SCALANCE W-700 IEEE 802.11n family before V6.6.0 are affected by multiple vulnerabilities.\n\nSiemens has released a new version for SCALANCE W-700 IEEE 802.11n family and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Siemens ProductCERT SSA-019200 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Communications, Information Technology, Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-019200: Multiple Vulnerabilities in SCALANCE W-700 IEEE 802.11n Devices Before V6.6.0 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-019200.json"
},
{
"category": "self",
"summary": "SSA-019200: Multiple Vulnerabilities in SCALANCE W-700 IEEE 802.11n Devices Before V6.6.0 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-019200.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-26-111-07 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-111-07.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-26-111-07 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-07"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Siemens SCALANCE",
"tracking": {
"current_release_date": "2026-04-21T06:00:00.000000Z",
"generator": {
"date": "2026-04-20T18:07:26.686293Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.5.0"
}
},
"id": "ICSA-26-111-07",
"initial_release_date": "2026-04-14T00:00:00.000000Z",
"revision_history": [
{
"date": "2026-04-14T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2026-04-21T06:00:00.000000Z",
"legacy_version": "CISA Republication",
"number": "2",
"summary": "Initial CISA Republication of Siemens ProductCERT SSA-019200 advisory"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)",
"product_id": "CSAFPID-0001",
"product_identification_helper": {
"model_numbers": [
"6GK5721-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)",
"product_id": "CSAFPID-0002",
"product_identification_helper": {
"model_numbers": [
"6GK5721-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)",
"product_id": "CSAFPID-0003",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)",
"product_id": "CSAFPID-0004",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)",
"product_id": "CSAFPID-0005",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)",
"product_id": "CSAFPID-0006",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)",
"product_id": "CSAFPID-0007",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)",
"product_id": "CSAFPID-0008",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)",
"product_id": "CSAFPID-0009",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AB6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)",
"product_id": "CSAFPID-0010",
"product_identification_helper": {
"model_numbers": [
"6GK5738-1GY00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)",
"product_id": "CSAFPID-0011",
"product_identification_helper": {
"model_numbers": [
"6GK5738-1GY00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)",
"product_id": "CSAFPID-0012",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)",
"product_id": "CSAFPID-0013",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)",
"product_id": "CSAFPID-0014",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)",
"product_id": "CSAFPID-0015",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)",
"product_id": "CSAFPID-0016",
"product_identification_helper": {
"model_numbers": [
"6GK5761-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)",
"product_id": "CSAFPID-0017",
"product_identification_helper": {
"model_numbers": [
"6GK5761-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)",
"product_id": "CSAFPID-0018",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FY00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)",
"product_id": "CSAFPID-0019",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FY00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)",
"product_id": "CSAFPID-0020",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)",
"product_id": "CSAFPID-0021",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)",
"product_id": "CSAFPID-0022",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)",
"product_id": "CSAFPID-0023",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)",
"product_id": "CSAFPID-0024",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AB6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)",
"product_id": "CSAFPID-0025",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)",
"product_id": "CSAFPID-0026",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)",
"product_id": "CSAFPID-0027",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)",
"product_id": "CSAFPID-0028",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)",
"product_id": "CSAFPID-0029",
"product_identification_helper": {
"model_numbers": [
"6GK5786-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)",
"product_id": "CSAFPID-0030",
"product_identification_helper": {
"model_numbers": [
"6GK5786-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)",
"product_id": "CSAFPID-0031",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)",
"product_id": "CSAFPID-0032",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)",
"product_id": "CSAFPID-0033",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)",
"product_id": "CSAFPID-0034",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FE00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)",
"product_id": "CSAFPID-0035",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FE00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)",
"product_id": "CSAFPID-0036",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2HC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)",
"product_id": "CSAFPID-0037",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2HC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)",
"product_id": "CSAFPID-0038",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)",
"product_id": "CSAFPID-0039",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)",
"product_id": "CSAFPID-0040",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)",
"product_id": "CSAFPID-0041",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)",
"product_id": "CSAFPID-0042",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)",
"product_id": "CSAFPID-0043",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)",
"product_id": "CSAFPID-0044",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)",
"product_id": "CSAFPID-0045",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)",
"product_id": "CSAFPID-0046",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)",
"product_id": "CSAFPID-0047",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)",
"product_id": "CSAFPID-0048",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)",
"product_id": "CSAFPID-0049",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-24588",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "summary",
"text": "The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn\u0027t require that the A-MSDU flag in the plaintext QoS header field is authenticated. Against devices that support receiving non-SSP A-MSDU frames (which is mandatory as part of 802.11n), an adversary can abuse this to inject arbitrary network packets.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-24588"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/306.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
{
"category": "mitigation",
"details": "Disable A-MSDU, if possible",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2020-24588"
},
{
"cve": "CVE-2020-26139",
"cwe": {
"id": "CWE-287",
"name": "Improper Authentication"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the kernel in NetBSD 7.1. An Access Point (AP) forwards EAPOL frames to other clients even though the sender has not yet successfully authenticated to the AP. This might be abused in projected Wi-Fi networks to launch denial-of-service attacks against connected clients and makes it easier to exploit other vulnerabilities in connected clients.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26139"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/287.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2020-26139"
},
{
"cve": "CVE-2020-26140",
"cwe": {
"id": "CWE-74",
"name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26140"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/74.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2020-26140"
},
{
"cve": "CVE-2020-26141",
"cwe": {
"id": "CWE-354",
"name": "Improper Validation of Integrity Check Value"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The Wi-Fi implementation does not verify the Message Integrity Check (authenticity) of fragmented TKIP frames. An adversary can abuse this to inject and possibly decrypt packets in WPA or WPA2 networks that support the TKIP data-confidentiality protocol.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26141"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/354.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2020-26141"
},
{
"cve": "CVE-2020-26143",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the ALFA Windows 10 driver 1030.36.604 for AWUS036ACH. The WEP, WPA, WPA2, and WPA3 implementations accept fragmented plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26143"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2020-26143"
},
{
"cve": "CVE-2020-26144",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext A-MSDU frames as long as the first 8 bytes correspond to a valid RFC1042 (i.e., LLC/SNAP) header for EAPOL. An adversary can abuse this to inject arbitrary network packets independent of the network configuration.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26144"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2020-26144"
},
{
"cve": "CVE-2020-26146",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WPA, WPA2, and WPA3 implementations reassemble fragments with non-consecutive packet numbers. An adversary can abuse this to exfiltrate selected fragments. This vulnerability is exploitable when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used. Note that WEP is vulnerable to this attack by design.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26146"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2020-26146"
},
{
"cve": "CVE-2020-26147",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the Linux kernel 5.8.9. The WEP, WPA, WPA2, and WPA3 implementations reassemble fragments even though some of them were sent in plaintext. This vulnerability can be abused to inject packets and/or exfiltrate selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26147"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2020-26147"
},
{
"cve": "CVE-2021-3712",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "ASN.1 strings are represented internally within OpenSSL as an ASN1_STRING structure which contains a buffer holding the string data and a field holding the buffer length. This contrasts with normal C strings which are repesented as a buffer for the string data which is terminated with a NUL (0) byte. Although not a strict requirement, ASN.1 strings that are parsed using OpenSSL\u0027s own \"d2i\" functions (and other similar parsing functions) as well as any string whose value has been set with the ASN1_STRING_set() function will additionally NUL terminate the byte array in the ASN1_STRING structure. However, it is possible for applications to directly construct valid ASN1_STRING structures which do not NUL terminate the byte array by directly setting the \"data\" and \"length\" fields in the ASN1_STRING array. This can also happen by using the ASN1_STRING_set0() function. Numerous OpenSSL functions that print ASN.1 data have been found to assume that the ASN1_STRING byte array will be NUL terminated, even though this is not guaranteed for strings that have been directly constructed. Where an application requests an ASN.1 structure to be printed, and where that ASN.1 structure contains ASN1_STRINGs that have been directly constructed by the application without NUL terminating the \"data\" field, then a read buffer overrun can occur. The same thing can also occur during name constraints processing of certificates (for example if a certificate has been directly constructed by the application instead of loading it via the OpenSSL parsing functions, and the certificate contains non NUL terminated ASN1_STRING structures). It can also occur in the X509_get1_email(), X509_REQ_get1_email() and X509_get1_ocsp() functions. If a malicious actor can cause an application to directly construct an ASN1_STRING and then process it through one of the affected OpenSSL functions then this issue could be hit. This might result in a crash (causing a Denial of Service attack). It could also result in the disclosure of private memory contents (such as private keys, or sensitive plaintext). Fixed in OpenSSL 1.1.1l (Affected 1.1.1-1.1.1k). Fixed in OpenSSL 1.0.2za (Affected 1.0.2-1.0.2y).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3712"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/125.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2021-3712"
},
{
"cve": "CVE-2022-0778",
"cwe": {
"id": "CWE-835",
"name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The BN_mod_sqrt() function in openSSL, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0778"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/835.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2022-0778"
},
{
"cve": "CVE-2022-31765",
"cwe": {
"id": "CWE-862",
"name": "Missing Authorization"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly authorize the change password function of the web interface.\r\nThis could allow low privileged users to escalate their privileges.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-31765"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/862.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2022-31765"
},
{
"cve": "CVE-2022-36323",
"cwe": {
"id": "CWE-74",
"name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36323"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/74.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2022-36323"
},
{
"cve": "CVE-2022-36324",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36324"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/770.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2022-36324"
},
{
"cve": "CVE-2022-36325",
"cwe": {
"id": "CWE-80",
"name": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36325"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/80.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2022-36325"
},
{
"cve": "CVE-2023-44373",
"cwe": {
"id": "CWE-74",
"name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44373"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/74.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0042",
"CSAFPID-0043",
"CSAFPID-0044",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049"
]
}
],
"title": "CVE-2023-44373"
}
]
}
CERTFR-2022-AVI-718
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | Teamcenter V12.4 versions antérieures à 12.4.0.15 | ||
| Siemens | N/A | CP-8000 (6MF2101-1AB10-0AA0) toutes versions | ||
| Siemens | N/A | SCALANCE W-1700 IEEE 802.11ac toutes versions | ||
| Siemens | N/A | Soft Starter ES versions antérieures à 16 | ||
| Siemens | N/A | Soft Starter ES versions antérieures à 15.1 | ||
| Siemens | N/A | SCALANCE XB-200 toutes versions | ||
| Siemens | N/A | SCALANCE XR-500 toutes versions | ||
| Siemens | N/A | Teamcenter V13.1 versions antérieures à 13.1.0.10 | ||
| Siemens | N/A | CP-8021 (6MF2802-1AA00) toutes versions | ||
| Siemens | N/A | Simcenter STAR-CCM+ | ||
| Siemens | N/A | CP-8022 (6MF2802-2AA00) toutes versions | ||
| Siemens | N/A | SCALANCE XC-200 toutes versions | ||
| Siemens | N/A | SCALANCE XP-200 toutes versions | ||
| Siemens | N/A | SCALANCE XM-400 toutes versions | ||
| Siemens | N/A | SCALANCE XF-200BA toutes versions | ||
| Siemens | N/A | Teamcenter V13.0 versions antérieures à 13.0.0.10 | ||
| Siemens | N/A | CP-8000 (6MF2101-0AB10-0AA0) toutes versions | ||
| Siemens | N/A | SCALANCE W-700 IEEE 802.11n toutes versions | ||
| Siemens | N/A | SCALANCE M-800 / S615 toutes versions | ||
| Siemens | N/A | SIMOCODE ES versions antérieures à 16 | ||
| Siemens | N/A | Teamcenter V13.3 versions antérieures à 13.3.0.5 | ||
| Siemens | N/A | SCALANCE W-700 IEEE 802.11ax toutes versions | ||
| Siemens | N/A | SCALANCE XR-300WG toutes versions | ||
| Siemens | N/A | Teamcenter V13.2 versions antérieures à 13.2.0.9 | ||
| Siemens | N/A | SIMOCODE ES versions antérieures à 15.1 | ||
| Siemens | N/A | Teamcenter V14.0 versions antérieures à 14.0.0.2 | ||
| Siemens | N/A | SCALANCE SC-600 versions antérieures à 2.3.1 |
| Title | Publication Time | Tags | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Teamcenter V12.4 versions ant\u00e9rieures \u00e0 12.4.0.15",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CP-8000 (6MF2101-1AB10-0AA0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W-1700 IEEE 802.11ac toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Soft Starter ES versions ant\u00e9rieures \u00e0 16",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Soft Starter ES versions ant\u00e9rieures \u00e0 15.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB-200 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR-500 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V13.1 versions ant\u00e9rieures \u00e0 13.1.0.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CP-8021 (6MF2802-1AA00) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Simcenter STAR-CCM+",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CP-8022 (6MF2802-2AA00) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC-200 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP-200 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XM-400 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF-200BA toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V13.0 versions ant\u00e9rieures \u00e0 13.0.0.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CP-8000 (6MF2101-0AB10-0AA0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W-700 IEEE 802.11n toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M-800 / S615 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOCODE ES versions ant\u00e9rieures \u00e0 16",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V13.3 versions ant\u00e9rieures \u00e0 13.3.0.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W-700 IEEE 802.11ax toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR-300WG toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V13.2 versions ant\u00e9rieures \u00e0 13.2.0.9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOCODE ES versions ant\u00e9rieures \u00e0 15.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V14.0 versions ant\u00e9rieures \u00e0 14.0.0.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE SC-600 versions ant\u00e9rieures \u00e0 2.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-46304",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-46304"
},
{
"name": "CVE-2020-7587",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7587"
},
{
"name": "CVE-2020-7588",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7588"
},
{
"name": "CVE-2022-34661",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34661"
},
{
"name": "CVE-2022-36325",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36325"
},
{
"name": "CVE-2020-7581",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7581"
},
{
"name": "CVE-2022-36323",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36323"
},
{
"name": "CVE-2022-36324",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36324"
},
{
"name": "CVE-2022-34659",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34659"
},
{
"name": "CVE-2022-34660",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34660"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-718",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-08-09T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-841348 du 9 ao\u00fbt 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-841348.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-555707 du 9 ao\u00fbt 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-555707.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-759952 du 9 ao\u00fbt 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-759952.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-185638 du 9 ao\u00fbt 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-185638.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-710008 du 9 ao\u00fbt 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html"
}
]
}
CERTFR-2026-AVI-0432
Vulnerability from certfr_avis - Published: 2026-04-14 - Updated: 2026-04-14
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une élévation de privilèges et un déni de service à distance.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | SIMATIC | SIMATIC IPC PX-39A versions antérieures à 29.01.09 | ||
| Siemens | SIMATIC | SIMATIC IPC627E toutes versions pour la vulnérabilité CVE-2025-2884 | ||
| Siemens | SIMATIC | SIMATIC Field PG M5 toutes versions pour la vulnérabilité CVE-2025-2884 | ||
| Siemens | SIMATIC | SIMATIC IPC BX-32A versions antérieures à 29.01.09 | ||
| Siemens | SIMATIC | SIMATIC IPC BX-39A versions antérieures à 29.01.09 | ||
| Siemens | SIMATIC | SIMATIC Field PG M6 toutes versions pour la vulnérabilité CVE-2025-2884 | ||
| Siemens | SIMATIC | SIMATIC IPC677E toutes versions pour la vulnérabilité CVE-2025-2884 | ||
| Siemens | SIMATIC | SIMATIC IPC PX-39A PRO versions antérieures à 29.01.09 | ||
| Siemens | SIMATIC | SIMATIC IPC BX-59A versions antérieures à 32.01.09 | ||
| Siemens | SIMATIC | SIMATIC IPC847E toutes versions pour la vulnérabilité CVE-2025-2884 | ||
| Siemens | SIMATIC | SIMATIC IPC427E versions antérieures à 21.01.20 | ||
| Siemens | SCALANCE | SCALANCE W-700 IEEE 802.11n versions antérieures à 6.6.0 | ||
| Siemens | SIMATIC | SIMATIC IPC477E versions antérieures à 21.01.20 | ||
| Siemens | SIMATIC | SIMATIC CN 4100 toutes versions. L'éditeur indique que le produit ne bénéficiera pas de correctif de sécurité pour la vulnérabilité CVE-2025-2884. | ||
| Siemens | SIMATIC | SIMATIC ITP1000 toutes versions pour la vulnérabilité CVE-2025-2884 | ||
| Siemens | SIMATIC | SIMATIC IPC477E PRO versions antérieures à 21.01.20 | ||
| Siemens | SIMATIC | SIMATIC IPC RW-548A versions antérieures à 34.01.02 | ||
| Siemens | SIMATIC | SIMATIC IPC PX-32A versions antérieures à 29.01.09 | ||
| Siemens | SIMATIC | SIMATIC IPC BX-56A versions antérieures à 32.01.09 | ||
| Siemens | SIMATIC | SIMATIC IPC277E toutes versions. L'éditeur indique que le produit ne bénéficiera pas de correctif de sécurité pour la vulnérabilité CVE-2025-2884. | ||
| Siemens | SIMATIC | SIMATIC IPC RW-528A versions antérieures à 34.01.02 | ||
| Siemens | SIMATIC | SIMATIC IPC647E toutes versions pour la vulnérabilité CVE-2025-2884 | ||
| Siemens | SIMATIC | SIMATIC IPC MD-57A versions antérieures à 30.01.10 | ||
| Siemens | SIMATIC | SIMATIC IPC227E toutes versions. L'éditeur indique que le produit ne bénéficiera pas de correctif de sécurité pour la vulnérabilité CVE-2025-2884. |
| Title | Publication Time | Tags | ||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC IPC PX-39A versions ant\u00e9rieures \u00e0 29.01.09",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC627E toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-2884",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Field PG M5 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-2884",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC BX-32A versions ant\u00e9rieures \u00e0 29.01.09",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC BX-39A versions ant\u00e9rieures \u00e0 29.01.09",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Field PG M6 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-2884",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC677E toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-2884",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC PX-39A PRO versions ant\u00e9rieures \u00e0 29.01.09",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC BX-59A versions ant\u00e9rieures \u00e0 32.01.09",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC847E toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-2884",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC427E versions ant\u00e9rieures \u00e0 21.01.20",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W-700 IEEE 802.11n versions ant\u00e9rieures \u00e0 6.6.0",
"product": {
"name": "SCALANCE",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC477E versions ant\u00e9rieures \u00e0 21.01.20",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CN 4100 toutes versions. L\u0027\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-2884.",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITP1000 toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-2884",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC477E PRO versions ant\u00e9rieures \u00e0 21.01.20",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC RW-548A versions ant\u00e9rieures \u00e0 34.01.02",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC PX-32A versions ant\u00e9rieures \u00e0 29.01.09",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC BX-56A versions ant\u00e9rieures \u00e0 32.01.09",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC277E toutes versions. L\u0027\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-2884.",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC RW-528A versions ant\u00e9rieures \u00e0 34.01.02",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC647E toutes versions pour la vuln\u00e9rabilit\u00e9 CVE-2025-2884",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC MD-57A versions ant\u00e9rieures \u00e0 30.01.10",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC227E toutes versions. L\u0027\u00e9diteur indique que le produit ne b\u00e9n\u00e9ficiera pas de correctif de s\u00e9curit\u00e9 pour la vuln\u00e9rabilit\u00e9 CVE-2025-2884.",
"product": {
"name": "SIMATIC",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2020-26139",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26139"
},
{
"name": "CVE-2020-26146",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26146"
},
{
"name": "CVE-2020-26143",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26143"
},
{
"name": "CVE-2020-24588",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-24588"
},
{
"name": "CVE-2020-26140",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26140"
},
{
"name": "CVE-2020-26144",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26144"
},
{
"name": "CVE-2022-36325",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36325"
},
{
"name": "CVE-2022-36323",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36323"
},
{
"name": "CVE-2020-26147",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26147"
},
{
"name": "CVE-2022-0778",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0778"
},
{
"name": "CVE-2022-36324",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36324"
},
{
"name": "CVE-2021-3712",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3712"
},
{
"name": "CVE-2020-26141",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26141"
},
{
"name": "CVE-2023-44373",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44373"
},
{
"name": "CVE-2025-2884",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-2884"
},
{
"name": "CVE-2022-31765",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-31765"
}
],
"initial_release_date": "2026-04-14T00:00:00",
"last_revision_date": "2026-04-14T00:00:00",
"links": [],
"reference": "CERTFR-2026-AVI-0432",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2026-04-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Siemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, une \u00e9l\u00e9vation de privil\u00e8ges et un d\u00e9ni de service \u00e0 distance.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": "2026-04-14",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-628843",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-628843.html"
},
{
"published_at": "2026-04-14",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-019200",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-019200.html"
}
]
}
CERTFR-2022-AVI-718
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | Teamcenter V12.4 versions antérieures à 12.4.0.15 | ||
| Siemens | N/A | CP-8000 (6MF2101-1AB10-0AA0) toutes versions | ||
| Siemens | N/A | SCALANCE W-1700 IEEE 802.11ac toutes versions | ||
| Siemens | N/A | Soft Starter ES versions antérieures à 16 | ||
| Siemens | N/A | Soft Starter ES versions antérieures à 15.1 | ||
| Siemens | N/A | SCALANCE XB-200 toutes versions | ||
| Siemens | N/A | SCALANCE XR-500 toutes versions | ||
| Siemens | N/A | Teamcenter V13.1 versions antérieures à 13.1.0.10 | ||
| Siemens | N/A | CP-8021 (6MF2802-1AA00) toutes versions | ||
| Siemens | N/A | Simcenter STAR-CCM+ | ||
| Siemens | N/A | CP-8022 (6MF2802-2AA00) toutes versions | ||
| Siemens | N/A | SCALANCE XC-200 toutes versions | ||
| Siemens | N/A | SCALANCE XP-200 toutes versions | ||
| Siemens | N/A | SCALANCE XM-400 toutes versions | ||
| Siemens | N/A | SCALANCE XF-200BA toutes versions | ||
| Siemens | N/A | Teamcenter V13.0 versions antérieures à 13.0.0.10 | ||
| Siemens | N/A | CP-8000 (6MF2101-0AB10-0AA0) toutes versions | ||
| Siemens | N/A | SCALANCE W-700 IEEE 802.11n toutes versions | ||
| Siemens | N/A | SCALANCE M-800 / S615 toutes versions | ||
| Siemens | N/A | SIMOCODE ES versions antérieures à 16 | ||
| Siemens | N/A | Teamcenter V13.3 versions antérieures à 13.3.0.5 | ||
| Siemens | N/A | SCALANCE W-700 IEEE 802.11ax toutes versions | ||
| Siemens | N/A | SCALANCE XR-300WG toutes versions | ||
| Siemens | N/A | Teamcenter V13.2 versions antérieures à 13.2.0.9 | ||
| Siemens | N/A | SIMOCODE ES versions antérieures à 15.1 | ||
| Siemens | N/A | Teamcenter V14.0 versions antérieures à 14.0.0.2 | ||
| Siemens | N/A | SCALANCE SC-600 versions antérieures à 2.3.1 |
| Title | Publication Time | Tags | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Teamcenter V12.4 versions ant\u00e9rieures \u00e0 12.4.0.15",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CP-8000 (6MF2101-1AB10-0AA0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W-1700 IEEE 802.11ac toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Soft Starter ES versions ant\u00e9rieures \u00e0 16",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Soft Starter ES versions ant\u00e9rieures \u00e0 15.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB-200 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR-500 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V13.1 versions ant\u00e9rieures \u00e0 13.1.0.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CP-8021 (6MF2802-1AA00) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Simcenter STAR-CCM+",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CP-8022 (6MF2802-2AA00) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC-200 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP-200 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XM-400 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF-200BA toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V13.0 versions ant\u00e9rieures \u00e0 13.0.0.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CP-8000 (6MF2101-0AB10-0AA0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W-700 IEEE 802.11n toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M-800 / S615 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOCODE ES versions ant\u00e9rieures \u00e0 16",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V13.3 versions ant\u00e9rieures \u00e0 13.3.0.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W-700 IEEE 802.11ax toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR-300WG toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V13.2 versions ant\u00e9rieures \u00e0 13.2.0.9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOCODE ES versions ant\u00e9rieures \u00e0 15.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V14.0 versions ant\u00e9rieures \u00e0 14.0.0.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE SC-600 versions ant\u00e9rieures \u00e0 2.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-46304",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-46304"
},
{
"name": "CVE-2020-7587",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7587"
},
{
"name": "CVE-2020-7588",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7588"
},
{
"name": "CVE-2022-34661",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34661"
},
{
"name": "CVE-2022-36325",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36325"
},
{
"name": "CVE-2020-7581",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7581"
},
{
"name": "CVE-2022-36323",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36323"
},
{
"name": "CVE-2022-36324",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36324"
},
{
"name": "CVE-2022-34659",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34659"
},
{
"name": "CVE-2022-34660",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34660"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-718",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-08-09T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-841348 du 9 ao\u00fbt 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-841348.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-555707 du 9 ao\u00fbt 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-555707.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-759952 du 9 ao\u00fbt 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-759952.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-185638 du 9 ao\u00fbt 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-185638.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-710008 du 9 ao\u00fbt 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html"
}
]
}
SSA-710008
Vulnerability from csaf_siemens - Published: 2022-08-09 00:00 - Updated: 2026-04-14 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
6GK6108-4AM00-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
6GK6108-4AM00-2DA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M804PB (6GK5804-0AP00-2AA2)
Siemens / SCALANCE M804PB (6GK5804-0AP00-2AA2)
|
6GK5804-0AP00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
Siemens / SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
|
6GK5812-1AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
Siemens / SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
|
6GK5812-1BA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
Siemens / SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
|
6GK5816-1AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
Siemens / SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
|
6GK5816-1BA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
Siemens / SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
|
6GK5826-2AB00-2AB2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-2 (6GK5874-2AA00-2AA2)
Siemens / SCALANCE M874-2 (6GK5874-2AA00-2AA2)
|
6GK5874-2AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-3 (6GK5874-3AA00-2AA2)
Siemens / SCALANCE M874-3 (6GK5874-3AA00-2AA2)
|
6GK5874-3AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-3 (6GK5876-3AA02-2BA2)
Siemens / SCALANCE M876-3 (6GK5876-3AA02-2BA2)
|
6GK5876-3AA02-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)
Siemens / SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)
|
6GK5876-3AA02-2EA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)
Siemens / SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)
|
6GK5876-4AA00-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)
Siemens / SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)
|
6GK5876-4AA00-2DA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)
Siemens / SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)
|
6GK5853-2EA00-2DA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)
Siemens / SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)
|
6GK5856-2EA00-3DA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)
Siemens / SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)
|
6GK5856-2EA00-3AA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)
Siemens / SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)
|
6GK5615-0AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC622-2C (6GK5622-2GS00-2AC2)
Siemens / SCALANCE SC622-2C (6GK5622-2GS00-2AC2)
|
6GK5622-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC626-2C (6GK5626-2GS00-2AC2)
Siemens / SCALANCE SC626-2C (6GK5626-2GS00-2AC2)
|
6GK5626-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC632-2C (6GK5632-2GS00-2AC2)
Siemens / SCALANCE SC632-2C (6GK5632-2GS00-2AC2)
|
6GK5632-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE SC636-2C (6GK5636-2GS00-2AC2)
Siemens / SCALANCE SC636-2C (6GK5636-2GS00-2AC2)
|
6GK5636-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE SC642-2C (6GK5642-2GS00-2AC2)
Siemens / SCALANCE SC642-2C (6GK5642-2GS00-2AC2)
|
6GK5642-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE SC646-2C (6GK5646-2GS00-2AC2)
Siemens / SCALANCE SC646-2C (6GK5646-2GS00-2AC2)
|
6GK5646-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)
Siemens / SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)
|
6GK5748-1GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)
Siemens / SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)
|
6GK5748-1GY01-0TA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)
Siemens / SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)
|
6GK5788-1GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)
Siemens / SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)
|
6GK5788-2GY01-0TA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)
Siemens / SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)
|
6GK5788-2GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)
Siemens / SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)
|
6GK5788-2HY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)
Siemens / SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)
|
6GK5763-1AL00-7DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)
Siemens / SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)
|
6GK5766-1GE00-7DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)
Siemens / SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)
|
6GK5766-1GE00-7DB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)
Siemens / SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)
|
6GK5766-1GE00-7TA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)
Siemens / SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)
|
6GK5766-1GE00-7TB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)
Siemens / SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)
|
6GK5763-1AL00-3AA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)
Siemens / SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)
|
6GK5763-1AL00-3DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)
Siemens / SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)
|
6GK5766-1GE00-3DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)
Siemens / SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)
|
6GK5766-1GE00-3DB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)
Siemens / SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)
|
6GK5205-3BB00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)
Siemens / SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)
|
6GK5205-3BB00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)
Siemens / SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)
|
6GK5205-3BD00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)
Siemens / SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)
|
6GK5205-3BD00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)
Siemens / SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)
|
6GK5205-3BF00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)
Siemens / SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)
|
6GK5205-3BF00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)
Siemens / SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)
|
6GK5208-0BA00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)
Siemens / SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)
|
6GK5208-0BA00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)
Siemens / SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)
|
6GK5213-3BD00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)
Siemens / SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)
|
6GK5213-3BD00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)
Siemens / SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)
|
6GK5213-3BB00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)
Siemens / SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)
|
6GK5213-3BB00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)
Siemens / SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)
|
6GK5213-3BF00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)
Siemens / SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)
|
6GK5213-3BF00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)
Siemens / SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)
|
6GK5216-0BA00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)
Siemens / SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)
|
6GK5216-0BA00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)
Siemens / SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)
|
6GK5206-2BD00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)
Siemens / SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)
|
6GK5206-2BB00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)
Siemens / SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)
|
6GK5206-2RS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)
Siemens / SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)
|
6GK5206-2RS00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)
Siemens / SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)
|
6GK5206-2RS00-5FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)
Siemens / SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)
|
6GK5206-2BS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)
Siemens / SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)
|
6GK5206-2BS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)
Siemens / SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)
|
6GK5206-2GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)
Siemens / SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)
|
6GK5206-2GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)
Siemens / SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)
|
6GK5206-2GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208 (6GK5208-0BA00-2AC2)
Siemens / SCALANCE XC208 (6GK5208-0BA00-2AC2)
|
6GK5208-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208EEC (6GK5208-0BA00-2FC2)
Siemens / SCALANCE XC208EEC (6GK5208-0BA00-2FC2)
|
6GK5208-0BA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G (6GK5208-0GA00-2AC2)
Siemens / SCALANCE XC208G (6GK5208-0GA00-2AC2)
|
6GK5208-0GA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)
Siemens / SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)
|
6GK5208-0GA00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)
Siemens / SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)
|
6GK5208-0GA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)
Siemens / SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)
|
6GK5208-0RA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)
Siemens / SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)
|
6GK5208-0RA00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216 (6GK5216-0BA00-2AC2)
Siemens / SCALANCE XC216 (6GK5216-0BA00-2AC2)
|
6GK5216-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)
Siemens / SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)
|
6GK5216-3RS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)
Siemens / SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)
|
6GK5216-3RS00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C (6GK5216-4BS00-2AC2)
Siemens / SCALANCE XC216-4C (6GK5216-4BS00-2AC2)
|
6GK5216-4BS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)
Siemens / SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)
|
6GK5216-4GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)
Siemens / SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)
|
6GK5216-4GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)
Siemens / SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)
|
6GK5216-4GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216EEC (6GK5216-0BA00-2FC2)
Siemens / SCALANCE XC216EEC (6GK5216-0BA00-2FC2)
|
6GK5216-0BA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224 (6GK5224-0BA00-2AC2)
Siemens / SCALANCE XC224 (6GK5224-0BA00-2AC2)
|
6GK5224-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)
Siemens / SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)
|
6GK5224-4GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)
Siemens / SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)
|
6GK5224-4GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)
Siemens / SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)
|
6GK5224-4GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204 (6GK5204-0BA00-2GF2)
Siemens / SCALANCE XF204 (6GK5204-0BA00-2GF2)
|
6GK5204-0BA00-2GF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)
Siemens / SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)
|
6GK5204-0BA00-2YF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)
Siemens / SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)
|
6GK5204-2AA00-2GF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)
Siemens / SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)
|
6GK5204-2AA00-2YF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-4C (6GK5408-4GP00-2AM2)
Siemens / SCALANCE XM408-4C (6GK5408-4GP00-2AM2)
|
6GK5408-4GP00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)
Siemens / SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)
|
6GK5408-4GQ00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-8C (6GK5408-8GS00-2AM2)
Siemens / SCALANCE XM408-8C (6GK5408-8GS00-2AM2)
|
6GK5408-8GS00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)
Siemens / SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)
|
6GK5408-8GR00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM416-4C (6GK5416-4GS00-2AM2)
Siemens / SCALANCE XM416-4C (6GK5416-4GS00-2AM2)
|
6GK5416-4GS00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)
Siemens / SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)
|
6GK5416-4GR00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208 (6GK5208-0HA00-2AS6)
Siemens / SCALANCE XP208 (6GK5208-0HA00-2AS6)
|
6GK5208-0HA00-2AS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)
Siemens / SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)
|
6GK5208-0HA00-2TS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208EEC (6GK5208-0HA00-2ES6)
Siemens / SCALANCE XP208EEC (6GK5208-0HA00-2ES6)
|
6GK5208-0HA00-2ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)
Siemens / SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)
|
6GK5208-0UA00-5ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (6GK5216-0HA00-2AS6)
Siemens / SCALANCE XP216 (6GK5216-0HA00-2AS6)
|
6GK5216-0HA00-2AS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)
Siemens / SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)
|
6GK5216-0HA00-2TS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216EEC (6GK5216-0HA00-2ES6)
Siemens / SCALANCE XP216EEC (6GK5216-0HA00-2ES6)
|
6GK5216-0HA00-2ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)
Siemens / SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)
|
6GK5216-0UA00-5ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)
Siemens / SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)
|
6GK5324-0BA00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)
Siemens / SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)
|
6GK5324-0BA00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)
Siemens / SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)
|
6GK5326-2QS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)
Siemens / SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)
|
6GK5326-2QS00-3RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)
Siemens / SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)
|
6GK5328-4FS00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)
Siemens / SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)
|
6GK5328-4FS00-2RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)
Siemens / SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)
|
6GK5328-4FS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)
Siemens / SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)
|
6GK5328-4FS00-3RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)
Siemens / SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)
|
6GK5328-4SS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)
Siemens / SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)
|
6GK5328-4SS00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)
Siemens / SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)
|
6GK5524-8GS00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)
Siemens / SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)
|
6GK5524-8GR00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)
Siemens / SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)
|
6GK5524-8GS00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)
Siemens / SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)
|
6GK5524-8GR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)
Siemens / SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)
|
6GK5524-8GS00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)
Siemens / SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)
|
6GK5524-8GR00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)
Siemens / SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)
|
6GK5526-8GS00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)
Siemens / SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)
|
6GK5526-8GR00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)
Siemens / SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)
|
6GK5526-8GS00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)
Siemens / SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)
|
6GK5526-8GR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)
Siemens / SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)
|
6GK5526-8GS00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)
Siemens / SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)
|
6GK5526-8GR00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (6GK5528-0AA00-2AR2)
Siemens / SCALANCE XR528-6M (6GK5528-0AA00-2AR2)
|
6GK5528-0AA00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)
Siemens / SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)
|
6GK5528-0AR00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)
Siemens / SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)
|
6GK5528-0AA00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)
Siemens / SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)
|
6GK5528-0AR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (6GK5552-0AA00-2AR2)
Siemens / SCALANCE XR552-12M (6GK5552-0AA00-2AR2)
|
6GK5552-0AA00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)
Siemens / SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)
|
6GK5552-0AR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)
Siemens / SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)
|
6GK5552-0AA00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)
Siemens / SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)
|
6GK5552-0AR00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)
Siemens / SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)
|
6AG1206-2BB00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)
Siemens / SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)
|
6AG1206-2BS00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)
Siemens / SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)
|
6AG1208-0BA00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)
Siemens / SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)
|
6AG1216-4BS00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
6GK6108-4AM00-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
6GK6108-4AM00-2DA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M804PB (6GK5804-0AP00-2AA2)
Siemens / SCALANCE M804PB (6GK5804-0AP00-2AA2)
|
6GK5804-0AP00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
Siemens / SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
|
6GK5812-1AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
Siemens / SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
|
6GK5812-1BA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
Siemens / SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
|
6GK5816-1AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
Siemens / SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
|
6GK5816-1BA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
Siemens / SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
|
6GK5826-2AB00-2AB2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-2 (6GK5874-2AA00-2AA2)
Siemens / SCALANCE M874-2 (6GK5874-2AA00-2AA2)
|
6GK5874-2AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-3 (6GK5874-3AA00-2AA2)
Siemens / SCALANCE M874-3 (6GK5874-3AA00-2AA2)
|
6GK5874-3AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-3 (6GK5876-3AA02-2BA2)
Siemens / SCALANCE M876-3 (6GK5876-3AA02-2BA2)
|
6GK5876-3AA02-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)
Siemens / SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)
|
6GK5876-3AA02-2EA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)
Siemens / SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)
|
6GK5876-4AA00-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)
Siemens / SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)
|
6GK5876-4AA00-2DA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)
Siemens / SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)
|
6GK5853-2EA00-2DA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)
Siemens / SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)
|
6GK5856-2EA00-3DA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)
Siemens / SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)
|
6GK5856-2EA00-3AA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)
Siemens / SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)
|
6GK5615-0AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC622-2C (6GK5622-2GS00-2AC2)
Siemens / SCALANCE SC622-2C (6GK5622-2GS00-2AC2)
|
6GK5622-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC626-2C (6GK5626-2GS00-2AC2)
Siemens / SCALANCE SC626-2C (6GK5626-2GS00-2AC2)
|
6GK5626-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC632-2C (6GK5632-2GS00-2AC2)
Siemens / SCALANCE SC632-2C (6GK5632-2GS00-2AC2)
|
6GK5632-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC636-2C (6GK5636-2GS00-2AC2)
Siemens / SCALANCE SC636-2C (6GK5636-2GS00-2AC2)
|
6GK5636-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC642-2C (6GK5642-2GS00-2AC2)
Siemens / SCALANCE SC642-2C (6GK5642-2GS00-2AC2)
|
6GK5642-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC646-2C (6GK5646-2GS00-2AC2)
Siemens / SCALANCE SC646-2C (6GK5646-2GS00-2AC2)
|
6GK5646-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)
Siemens / SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)
|
6GK5748-1GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)
Siemens / SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)
|
6GK5748-1GY01-0TA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)
Siemens / SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)
|
6GK5788-1GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)
Siemens / SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)
|
6GK5788-2GY01-0TA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)
Siemens / SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)
|
6GK5788-2GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)
Siemens / SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)
|
6GK5788-2HY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)
Siemens / SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)
|
6GK5763-1AL00-7DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)
Siemens / SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)
|
6GK5766-1GE00-7DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)
Siemens / SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)
|
6GK5766-1GE00-7DB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)
Siemens / SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)
|
6GK5766-1GE00-7TA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)
Siemens / SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)
|
6GK5766-1GE00-7TB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)
Siemens / SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)
|
6GK5763-1AL00-3AA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)
Siemens / SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)
|
6GK5763-1AL00-3DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)
Siemens / SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)
|
6GK5766-1GE00-3DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)
Siemens / SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)
|
6GK5766-1GE00-3DB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)
Siemens / SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)
|
6GK5205-3BB00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)
Siemens / SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)
|
6GK5205-3BB00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)
Siemens / SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)
|
6GK5205-3BD00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)
Siemens / SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)
|
6GK5205-3BD00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)
Siemens / SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)
|
6GK5205-3BF00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)
Siemens / SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)
|
6GK5205-3BF00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)
Siemens / SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)
|
6GK5208-0BA00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)
Siemens / SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)
|
6GK5208-0BA00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)
Siemens / SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)
|
6GK5213-3BD00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)
Siemens / SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)
|
6GK5213-3BD00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)
Siemens / SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)
|
6GK5213-3BB00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)
Siemens / SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)
|
6GK5213-3BB00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)
Siemens / SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)
|
6GK5213-3BF00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)
Siemens / SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)
|
6GK5213-3BF00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)
Siemens / SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)
|
6GK5216-0BA00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)
Siemens / SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)
|
6GK5216-0BA00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)
Siemens / SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)
|
6GK5206-2BD00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)
Siemens / SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)
|
6GK5206-2BB00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)
Siemens / SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)
|
6GK5206-2RS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)
Siemens / SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)
|
6GK5206-2RS00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)
Siemens / SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)
|
6GK5206-2RS00-5FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)
Siemens / SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)
|
6GK5206-2BS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)
Siemens / SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)
|
6GK5206-2BS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)
Siemens / SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)
|
6GK5206-2GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)
Siemens / SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)
|
6GK5206-2GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)
Siemens / SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)
|
6GK5206-2GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208 (6GK5208-0BA00-2AC2)
Siemens / SCALANCE XC208 (6GK5208-0BA00-2AC2)
|
6GK5208-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208EEC (6GK5208-0BA00-2FC2)
Siemens / SCALANCE XC208EEC (6GK5208-0BA00-2FC2)
|
6GK5208-0BA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G (6GK5208-0GA00-2AC2)
Siemens / SCALANCE XC208G (6GK5208-0GA00-2AC2)
|
6GK5208-0GA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)
Siemens / SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)
|
6GK5208-0GA00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)
Siemens / SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)
|
6GK5208-0GA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)
Siemens / SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)
|
6GK5208-0RA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)
Siemens / SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)
|
6GK5208-0RA00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216 (6GK5216-0BA00-2AC2)
Siemens / SCALANCE XC216 (6GK5216-0BA00-2AC2)
|
6GK5216-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)
Siemens / SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)
|
6GK5216-3RS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)
Siemens / SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)
|
6GK5216-3RS00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C (6GK5216-4BS00-2AC2)
Siemens / SCALANCE XC216-4C (6GK5216-4BS00-2AC2)
|
6GK5216-4BS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)
Siemens / SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)
|
6GK5216-4GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)
Siemens / SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)
|
6GK5216-4GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)
Siemens / SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)
|
6GK5216-4GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216EEC (6GK5216-0BA00-2FC2)
Siemens / SCALANCE XC216EEC (6GK5216-0BA00-2FC2)
|
6GK5216-0BA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224 (6GK5224-0BA00-2AC2)
Siemens / SCALANCE XC224 (6GK5224-0BA00-2AC2)
|
6GK5224-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)
Siemens / SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)
|
6GK5224-4GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)
Siemens / SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)
|
6GK5224-4GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)
Siemens / SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)
|
6GK5224-4GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204 (6GK5204-0BA00-2GF2)
Siemens / SCALANCE XF204 (6GK5204-0BA00-2GF2)
|
6GK5204-0BA00-2GF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)
Siemens / SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)
|
6GK5204-0BA00-2YF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)
Siemens / SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)
|
6GK5204-2AA00-2GF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)
Siemens / SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)
|
6GK5204-2AA00-2YF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-4C (6GK5408-4GP00-2AM2)
Siemens / SCALANCE XM408-4C (6GK5408-4GP00-2AM2)
|
6GK5408-4GP00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)
Siemens / SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)
|
6GK5408-4GQ00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-8C (6GK5408-8GS00-2AM2)
Siemens / SCALANCE XM408-8C (6GK5408-8GS00-2AM2)
|
6GK5408-8GS00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)
Siemens / SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)
|
6GK5408-8GR00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM416-4C (6GK5416-4GS00-2AM2)
Siemens / SCALANCE XM416-4C (6GK5416-4GS00-2AM2)
|
6GK5416-4GS00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)
Siemens / SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)
|
6GK5416-4GR00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208 (6GK5208-0HA00-2AS6)
Siemens / SCALANCE XP208 (6GK5208-0HA00-2AS6)
|
6GK5208-0HA00-2AS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)
Siemens / SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)
|
6GK5208-0HA00-2TS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208EEC (6GK5208-0HA00-2ES6)
Siemens / SCALANCE XP208EEC (6GK5208-0HA00-2ES6)
|
6GK5208-0HA00-2ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)
Siemens / SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)
|
6GK5208-0UA00-5ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (6GK5216-0HA00-2AS6)
Siemens / SCALANCE XP216 (6GK5216-0HA00-2AS6)
|
6GK5216-0HA00-2AS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)
Siemens / SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)
|
6GK5216-0HA00-2TS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216EEC (6GK5216-0HA00-2ES6)
Siemens / SCALANCE XP216EEC (6GK5216-0HA00-2ES6)
|
6GK5216-0HA00-2ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)
Siemens / SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)
|
6GK5216-0UA00-5ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)
Siemens / SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)
|
6GK5324-0BA00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)
Siemens / SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)
|
6GK5324-0BA00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)
Siemens / SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)
|
6GK5326-2QS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)
Siemens / SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)
|
6GK5326-2QS00-3RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)
Siemens / SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)
|
6GK5328-4FS00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)
Siemens / SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)
|
6GK5328-4FS00-2RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)
Siemens / SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)
|
6GK5328-4FS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)
Siemens / SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)
|
6GK5328-4FS00-3RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)
Siemens / SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)
|
6GK5328-4SS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)
Siemens / SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)
|
6GK5328-4SS00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)
Siemens / SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)
|
6GK5524-8GS00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)
Siemens / SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)
|
6GK5524-8GR00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)
Siemens / SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)
|
6GK5524-8GS00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)
Siemens / SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)
|
6GK5524-8GR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)
Siemens / SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)
|
6GK5524-8GS00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)
Siemens / SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)
|
6GK5524-8GR00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)
Siemens / SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)
|
6GK5526-8GS00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)
Siemens / SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)
|
6GK5526-8GR00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)
Siemens / SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)
|
6GK5526-8GS00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)
Siemens / SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)
|
6GK5526-8GR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)
Siemens / SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)
|
6GK5526-8GS00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)
Siemens / SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)
|
6GK5526-8GR00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (6GK5528-0AA00-2AR2)
Siemens / SCALANCE XR528-6M (6GK5528-0AA00-2AR2)
|
6GK5528-0AA00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)
Siemens / SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)
|
6GK5528-0AR00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)
Siemens / SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)
|
6GK5528-0AA00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)
Siemens / SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)
|
6GK5528-0AR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (6GK5552-0AA00-2AR2)
Siemens / SCALANCE XR552-12M (6GK5552-0AA00-2AR2)
|
6GK5552-0AA00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)
Siemens / SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)
|
6GK5552-0AR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)
Siemens / SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)
|
6GK5552-0AA00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)
Siemens / SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)
|
6GK5552-0AR00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)
Siemens / SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)
|
6AG1206-2BB00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)
Siemens / SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)
|
6AG1206-2BS00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)
Siemens / SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)
|
6AG1208-0BA00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)
Siemens / SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)
|
6AG1216-4BS00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
Siemens / RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)
|
6GK6108-4AM00-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
Siemens / RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)
|
6GK6108-4AM00-2DA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M804PB (6GK5804-0AP00-2AA2)
Siemens / SCALANCE M804PB (6GK5804-0AP00-2AA2)
|
6GK5804-0AP00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
Siemens / SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)
|
6GK5812-1AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
Siemens / SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)
|
6GK5812-1BA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
Siemens / SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)
|
6GK5816-1AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
Siemens / SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)
|
6GK5816-1BA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
Siemens / SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)
|
6GK5826-2AB00-2AB2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-2 (6GK5874-2AA00-2AA2)
Siemens / SCALANCE M874-2 (6GK5874-2AA00-2AA2)
|
6GK5874-2AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M874-3 (6GK5874-3AA00-2AA2)
Siemens / SCALANCE M874-3 (6GK5874-3AA00-2AA2)
|
6GK5874-3AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-3 (6GK5876-3AA02-2BA2)
Siemens / SCALANCE M876-3 (6GK5876-3AA02-2BA2)
|
6GK5876-3AA02-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)
Siemens / SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)
|
6GK5876-3AA02-2EA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)
Siemens / SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)
|
6GK5876-4AA00-2BA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)
Siemens / SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)
|
6GK5876-4AA00-2DA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)
Siemens / SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)
|
6GK5853-2EA00-2DA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)
Siemens / SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)
|
6GK5856-2EA00-3DA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)
Siemens / SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)
|
6GK5856-2EA00-3AA1
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)
Siemens / SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)
|
6GK5615-0AA00-2AA2
|
vers:intdot/<7.1.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC622-2C (6GK5622-2GS00-2AC2)
Siemens / SCALANCE SC622-2C (6GK5622-2GS00-2AC2)
|
6GK5622-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC626-2C (6GK5626-2GS00-2AC2)
Siemens / SCALANCE SC626-2C (6GK5626-2GS00-2AC2)
|
6GK5626-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE SC632-2C (6GK5632-2GS00-2AC2)
Siemens / SCALANCE SC632-2C (6GK5632-2GS00-2AC2)
|
6GK5632-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE SC636-2C (6GK5636-2GS00-2AC2)
Siemens / SCALANCE SC636-2C (6GK5636-2GS00-2AC2)
|
6GK5636-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE SC642-2C (6GK5642-2GS00-2AC2)
Siemens / SCALANCE SC642-2C (6GK5642-2GS00-2AC2)
|
6GK5642-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE SC646-2C (6GK5646-2GS00-2AC2)
Siemens / SCALANCE SC646-2C (6GK5646-2GS00-2AC2)
|
6GK5646-2GS00-2AC2
|
vers:intdot/<2.3.1 |
Mitigation
Mitigation
Vendor Fix
|
|
SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)
Siemens / SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)
|
6GK5748-1GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)
Siemens / SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)
|
6GK5748-1GY01-0TA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)
Siemens / SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)
|
6GK5788-1GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)
Siemens / SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)
|
6GK5788-2GY01-0TA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)
Siemens / SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)
|
6GK5788-2GY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)
Siemens / SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)
|
6GK5788-2HY01-0AA0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)
Siemens / SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)
|
6GK5763-1AL00-7DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)
Siemens / SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)
|
6GK5766-1GE00-7DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)
Siemens / SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)
|
6GK5766-1GE00-7DB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)
Siemens / SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)
|
6GK5766-1GE00-7TA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)
Siemens / SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)
|
6GK5766-1GE00-7TB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)
Siemens / SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)
|
6GK5763-1AL00-3AA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)
Siemens / SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)
|
6GK5763-1AL00-3DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)
Siemens / SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)
|
6GK5766-1GE00-3DA0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)
Siemens / SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)
|
6GK5766-1GE00-3DB0
|
vers:intdot/<2.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)
Siemens / SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)
|
6GK5205-3BB00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)
Siemens / SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)
|
6GK5205-3BB00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)
Siemens / SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)
|
6GK5205-3BD00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)
Siemens / SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)
|
6GK5205-3BD00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)
Siemens / SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)
|
6GK5205-3BF00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)
Siemens / SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)
|
6GK5205-3BF00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)
Siemens / SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)
|
6GK5208-0BA00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)
Siemens / SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)
|
6GK5208-0BA00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)
Siemens / SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)
|
6GK5213-3BD00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)
Siemens / SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)
|
6GK5213-3BD00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)
Siemens / SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)
|
6GK5213-3BB00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)
Siemens / SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)
|
6GK5213-3BB00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)
Siemens / SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)
|
6GK5213-3BF00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)
Siemens / SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)
|
6GK5213-3BF00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)
Siemens / SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)
|
6GK5216-0BA00-2TB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)
Siemens / SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)
|
6GK5216-0BA00-2AB2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)
Siemens / SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)
|
6GK5206-2BD00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)
Siemens / SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)
|
6GK5206-2BB00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)
Siemens / SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)
|
6GK5206-2RS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)
Siemens / SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)
|
6GK5206-2RS00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)
Siemens / SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)
|
6GK5206-2RS00-5FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)
Siemens / SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)
|
6GK5206-2BS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)
Siemens / SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)
|
6GK5206-2BS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)
Siemens / SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)
|
6GK5206-2GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)
Siemens / SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)
|
6GK5206-2GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)
Siemens / SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)
|
6GK5206-2GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208 (6GK5208-0BA00-2AC2)
Siemens / SCALANCE XC208 (6GK5208-0BA00-2AC2)
|
6GK5208-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208EEC (6GK5208-0BA00-2FC2)
Siemens / SCALANCE XC208EEC (6GK5208-0BA00-2FC2)
|
6GK5208-0BA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G (6GK5208-0GA00-2AC2)
Siemens / SCALANCE XC208G (6GK5208-0GA00-2AC2)
|
6GK5208-0GA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)
Siemens / SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)
|
6GK5208-0GA00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)
Siemens / SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)
|
6GK5208-0GA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)
Siemens / SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)
|
6GK5208-0RA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)
Siemens / SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)
|
6GK5208-0RA00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216 (6GK5216-0BA00-2AC2)
Siemens / SCALANCE XC216 (6GK5216-0BA00-2AC2)
|
6GK5216-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)
Siemens / SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)
|
6GK5216-3RS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)
Siemens / SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)
|
6GK5216-3RS00-5AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C (6GK5216-4BS00-2AC2)
Siemens / SCALANCE XC216-4C (6GK5216-4BS00-2AC2)
|
6GK5216-4BS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)
Siemens / SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)
|
6GK5216-4GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)
Siemens / SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)
|
6GK5216-4GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)
Siemens / SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)
|
6GK5216-4GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC216EEC (6GK5216-0BA00-2FC2)
Siemens / SCALANCE XC216EEC (6GK5216-0BA00-2FC2)
|
6GK5216-0BA00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224 (6GK5224-0BA00-2AC2)
Siemens / SCALANCE XC224 (6GK5224-0BA00-2AC2)
|
6GK5224-0BA00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)
Siemens / SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)
|
6GK5224-4GS00-2AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)
Siemens / SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)
|
6GK5224-4GS00-2TC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)
Siemens / SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)
|
6GK5224-4GS00-2FC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204 (6GK5204-0BA00-2GF2)
Siemens / SCALANCE XF204 (6GK5204-0BA00-2GF2)
|
6GK5204-0BA00-2GF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)
Siemens / SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)
|
6GK5204-0BA00-2YF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)
Siemens / SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)
|
6GK5204-2AA00-2GF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)
Siemens / SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)
|
6GK5204-2AA00-2YF2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-4C (6GK5408-4GP00-2AM2)
Siemens / SCALANCE XM408-4C (6GK5408-4GP00-2AM2)
|
6GK5408-4GP00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)
Siemens / SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)
|
6GK5408-4GQ00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-8C (6GK5408-8GS00-2AM2)
Siemens / SCALANCE XM408-8C (6GK5408-8GS00-2AM2)
|
6GK5408-8GS00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)
Siemens / SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)
|
6GK5408-8GR00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM416-4C (6GK5416-4GS00-2AM2)
Siemens / SCALANCE XM416-4C (6GK5416-4GS00-2AM2)
|
6GK5416-4GS00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)
Siemens / SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)
|
6GK5416-4GR00-2AM2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208 (6GK5208-0HA00-2AS6)
Siemens / SCALANCE XP208 (6GK5208-0HA00-2AS6)
|
6GK5208-0HA00-2AS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)
Siemens / SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)
|
6GK5208-0HA00-2TS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208EEC (6GK5208-0HA00-2ES6)
Siemens / SCALANCE XP208EEC (6GK5208-0HA00-2ES6)
|
6GK5208-0HA00-2ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)
Siemens / SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)
|
6GK5208-0UA00-5ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (6GK5216-0HA00-2AS6)
Siemens / SCALANCE XP216 (6GK5216-0HA00-2AS6)
|
6GK5216-0HA00-2AS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)
Siemens / SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)
|
6GK5216-0HA00-2TS6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216EEC (6GK5216-0HA00-2ES6)
Siemens / SCALANCE XP216EEC (6GK5216-0HA00-2ES6)
|
6GK5216-0HA00-2ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)
Siemens / SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)
|
6GK5216-0UA00-5ES6
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)
Siemens / SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)
|
6GK5324-0BA00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)
Siemens / SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)
|
6GK5324-0BA00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)
Siemens / SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)
|
6GK5326-2QS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)
Siemens / SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)
|
6GK5326-2QS00-3RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)
Siemens / SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)
|
6GK5328-4FS00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)
Siemens / SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)
|
6GK5328-4FS00-2RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)
Siemens / SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)
|
6GK5328-4FS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)
Siemens / SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)
|
6GK5328-4FS00-3RR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)
Siemens / SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)
|
6GK5328-4SS00-3AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)
Siemens / SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)
|
6GK5328-4SS00-2AR3
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)
Siemens / SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)
|
6GK5524-8GS00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)
Siemens / SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)
|
6GK5524-8GR00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)
Siemens / SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)
|
6GK5524-8GS00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)
Siemens / SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)
|
6GK5524-8GR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)
Siemens / SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)
|
6GK5524-8GS00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)
Siemens / SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)
|
6GK5524-8GR00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)
Siemens / SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)
|
6GK5526-8GS00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)
Siemens / SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)
|
6GK5526-8GR00-3AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)
Siemens / SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)
|
6GK5526-8GS00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)
Siemens / SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)
|
6GK5526-8GR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)
Siemens / SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)
|
6GK5526-8GS00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)
Siemens / SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)
|
6GK5526-8GR00-4AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (6GK5528-0AA00-2AR2)
Siemens / SCALANCE XR528-6M (6GK5528-0AA00-2AR2)
|
6GK5528-0AA00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)
Siemens / SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)
|
6GK5528-0AR00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)
Siemens / SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)
|
6GK5528-0AA00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)
Siemens / SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)
|
6GK5528-0AR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (6GK5552-0AA00-2AR2)
Siemens / SCALANCE XR552-12M (6GK5552-0AA00-2AR2)
|
6GK5552-0AA00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)
Siemens / SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)
|
6GK5552-0AR00-2AR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)
Siemens / SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)
|
6GK5552-0AA00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)
Siemens / SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)
|
6GK5552-0AR00-2HR2
|
vers:intdot/<6.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)
Siemens / SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)
|
6AG1206-2BB00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)
Siemens / SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)
|
6AG1206-2BS00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)
Siemens / SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)
|
6AG1208-0BA00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)
Siemens / SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)
|
6AG1216-4BS00-7AC2
|
vers:intdot/<4.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "SCALANCE devices contain multiple vulnerabilities in MSPS based product lines that could allow authenticated remote attackers to execute custom code or create a XSS situation, as well as unauthenticated remote attackers to create a denial of service condition.\n\nSiemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-710008: Multiple Web Vulnerabilities in SCALANCE Products - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html"
},
{
"category": "self",
"summary": "SSA-710008: Multiple Web Vulnerabilities in SCALANCE Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-710008.json"
}
],
"title": "SSA-710008: Multiple Web Vulnerabilities in SCALANCE Products",
"tracking": {
"current_release_date": "2026-04-14T00:00:00.000Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-710008",
"initial_release_date": "2022-08-09T00:00:00.000Z",
"revision_history": [
{
"date": "2022-08-09T00:00:00.000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2022-09-13T00:00:00.000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for SCALANCE M-800, SCALANCE MUM-800 and RUGGEDCOM RM1224 families, as well as for SCALANCE S615 families; All affected product families were expanded"
},
{
"date": "2023-01-10T00:00:00.000Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added fix for SCALANCE W-700 IEEE 802.11ax product family"
},
{
"date": "2023-04-11T00:00:00.000Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added fix for SCALANCE XM-400/XR-500 family and for SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG family"
},
{
"date": "2023-10-10T00:00:00.000Z",
"legacy_version": "1.4",
"number": "5",
"summary": "Added that SCALANCE SC-600 family was also affected by CVE-2022-36324"
},
{
"date": "2026-04-14T00:00:00.000Z",
"legacy_version": "1.5",
"number": "6",
"summary": "Added fix for SCALANCE W-700 IEEE 802.11n family"
}
],
"status": "interim",
"version": "6"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"6GK6108-4AM00-2BA2"
]
}
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)",
"product_id": "2",
"product_identification_helper": {
"model_numbers": [
"6GK6108-4AM00-2DA2"
]
}
}
}
],
"category": "product_name",
"name": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)",
"product_id": "3",
"product_identification_helper": {
"model_numbers": [
"6GK5804-0AP00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M804PB (6GK5804-0AP00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)",
"product_id": "4",
"product_identification_helper": {
"model_numbers": [
"6GK5812-1AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)",
"product_id": "5",
"product_identification_helper": {
"model_numbers": [
"6GK5812-1BA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)",
"product_id": "6",
"product_identification_helper": {
"model_numbers": [
"6GK5816-1AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)",
"product_id": "7",
"product_identification_helper": {
"model_numbers": [
"6GK5816-1BA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)",
"product_id": "8",
"product_identification_helper": {
"model_numbers": [
"6GK5826-2AB00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)",
"product_id": "9",
"product_identification_helper": {
"model_numbers": [
"6GK5874-2AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M874-2 (6GK5874-2AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)",
"product_id": "10",
"product_identification_helper": {
"model_numbers": [
"6GK5874-3AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M874-3 (6GK5874-3AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M876-3 (6GK5876-3AA02-2BA2)",
"product_id": "11",
"product_identification_helper": {
"model_numbers": [
"6GK5876-3AA02-2BA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M876-3 (6GK5876-3AA02-2BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)",
"product_id": "12",
"product_identification_helper": {
"model_numbers": [
"6GK5876-3AA02-2EA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)",
"product_id": "13",
"product_identification_helper": {
"model_numbers": [
"6GK5876-4AA00-2BA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)",
"product_id": "14",
"product_identification_helper": {
"model_numbers": [
"6GK5876-4AA00-2DA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)",
"product_id": "15",
"product_identification_helper": {
"model_numbers": [
"6GK5853-2EA00-2DA1"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)",
"product_id": "16",
"product_identification_helper": {
"model_numbers": [
"6GK5856-2EA00-3DA1"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)",
"product_id": "17",
"product_identification_helper": {
"model_numbers": [
"6GK5856-2EA00-3AA1"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c7.1.2",
"product": {
"name": "SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)",
"product_id": "18",
"product_identification_helper": {
"model_numbers": [
"6GK5615-0AA00-2AA2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.3.1",
"product": {
"name": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2)",
"product_id": "19",
"product_identification_helper": {
"model_numbers": [
"6GK5622-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.3.1",
"product": {
"name": "SCALANCE SC626-2C (6GK5626-2GS00-2AC2)",
"product_id": "20",
"product_identification_helper": {
"model_numbers": [
"6GK5626-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC626-2C (6GK5626-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.3.1",
"product": {
"name": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2)",
"product_id": "21",
"product_identification_helper": {
"model_numbers": [
"6GK5632-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.3.1",
"product": {
"name": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2)",
"product_id": "22",
"product_identification_helper": {
"model_numbers": [
"6GK5636-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.3.1",
"product": {
"name": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2)",
"product_id": "23",
"product_identification_helper": {
"model_numbers": [
"6GK5642-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.3.1",
"product": {
"name": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2)",
"product_id": "24",
"product_identification_helper": {
"model_numbers": [
"6GK5646-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)",
"product_id": "25",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GY01-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)",
"product_id": "26",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GY01-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)",
"product_id": "27",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1GY01-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)",
"product_id": "28",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GY01-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)",
"product_id": "29",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GY01-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)",
"product_id": "30",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2HY01-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)",
"product_id": "31",
"product_identification_helper": {
"model_numbers": [
"6GK5721-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)",
"product_id": "32",
"product_identification_helper": {
"model_numbers": [
"6GK5721-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)",
"product_id": "33",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)",
"product_id": "34",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)",
"product_id": "35",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)",
"product_id": "36",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)",
"product_id": "37",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)",
"product_id": "38",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)",
"product_id": "39",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AB6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)",
"product_id": "40",
"product_identification_helper": {
"model_numbers": [
"6GK5738-1GY00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)",
"product_id": "41",
"product_identification_helper": {
"model_numbers": [
"6GK5738-1GY00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)",
"product_id": "42",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)",
"product_id": "43",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)",
"product_id": "44",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)",
"product_id": "45",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)",
"product_id": "46",
"product_identification_helper": {
"model_numbers": [
"6GK5761-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)",
"product_id": "47",
"product_identification_helper": {
"model_numbers": [
"6GK5761-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)",
"product_id": "48",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FY00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)",
"product_id": "49",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FY00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)",
"product_id": "50",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)",
"product_id": "51",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)",
"product_id": "52",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)",
"product_id": "53",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)",
"product_id": "54",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AB6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)",
"product_id": "55",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)",
"product_id": "56",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)",
"product_id": "57",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)",
"product_id": "58",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)",
"product_id": "59",
"product_identification_helper": {
"model_numbers": [
"6GK5786-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)",
"product_id": "60",
"product_identification_helper": {
"model_numbers": [
"6GK5786-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)",
"product_id": "61",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)",
"product_id": "62",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)",
"product_id": "63",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)",
"product_id": "64",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FE00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)",
"product_id": "65",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FE00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)",
"product_id": "66",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2HC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)",
"product_id": "67",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2HC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)",
"product_id": "68",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)",
"product_id": "69",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)",
"product_id": "70",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)",
"product_id": "71",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)",
"product_id": "72",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)",
"product_id": "73",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)",
"product_id": "74",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)",
"product_id": "75",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)",
"product_id": "76",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)",
"product_id": "77",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)",
"product_id": "78",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)",
"product_id": "79",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)",
"product_id": "80",
"product_identification_helper": {
"model_numbers": [
"6GK5763-1AL00-7DA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)",
"product_id": "81",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-7DA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM766-1 (6GK5766-1GE00-7DA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)",
"product_id": "82",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-7DB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)",
"product_id": "83",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-7TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)",
"product_id": "84",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-7TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)",
"product_id": "85",
"product_identification_helper": {
"model_numbers": [
"6GK5763-1AL00-3AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)",
"product_id": "86",
"product_identification_helper": {
"model_numbers": [
"6GK5763-1AL00-3DA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)",
"product_id": "87",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-3DA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM766-1 (6GK5766-1GE00-3DA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.0.0",
"product": {
"name": "SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)",
"product_id": "88",
"product_identification_helper": {
"model_numbers": [
"6GK5766-1GE00-3DB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)",
"product_id": "89",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BB00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)",
"product_id": "90",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BB00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)",
"product_id": "91",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BD00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)",
"product_id": "92",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BD00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)",
"product_id": "93",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BF00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)",
"product_id": "94",
"product_identification_helper": {
"model_numbers": [
"6GK5205-3BF00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)",
"product_id": "95",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)",
"product_id": "96",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)",
"product_id": "97",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BD00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)",
"product_id": "98",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BD00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)",
"product_id": "99",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BB00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)",
"product_id": "100",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BB00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)",
"product_id": "101",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BF00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)",
"product_id": "102",
"product_identification_helper": {
"model_numbers": [
"6GK5213-3BF00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)",
"product_id": "103",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0BA00-2TB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)",
"product_id": "104",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0BA00-2AB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)",
"product_id": "105",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BD00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)",
"product_id": "106",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BB00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)",
"product_id": "107",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2RS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)",
"product_id": "108",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2RS00-5AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)",
"product_id": "109",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2RS00-5FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)",
"product_id": "110",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)",
"product_id": "111",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2BS00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)",
"product_id": "112",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)",
"product_id": "113",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2GS00-2TC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)",
"product_id": "114",
"product_identification_helper": {
"model_numbers": [
"6GK5206-2GS00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC208 (6GK5208-0BA00-2AC2)",
"product_id": "115",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208 (6GK5208-0BA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC208EEC (6GK5208-0BA00-2FC2)",
"product_id": "116",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0BA00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208EEC (6GK5208-0BA00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC208G (6GK5208-0GA00-2AC2)",
"product_id": "117",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0GA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G (6GK5208-0GA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)",
"product_id": "118",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0GA00-2TC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)",
"product_id": "119",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0GA00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G EEC (6GK5208-0GA00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)",
"product_id": "120",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0RA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G PoE (6GK5208-0RA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)",
"product_id": "121",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0RA00-5AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216 (6GK5216-0BA00-2AC2)",
"product_id": "122",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0BA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216 (6GK5216-0BA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)",
"product_id": "123",
"product_identification_helper": {
"model_numbers": [
"6GK5216-3RS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)",
"product_id": "124",
"product_identification_helper": {
"model_numbers": [
"6GK5216-3RS00-5AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216-4C (6GK5216-4BS00-2AC2)",
"product_id": "125",
"product_identification_helper": {
"model_numbers": [
"6GK5216-4BS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-4C (6GK5216-4BS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)",
"product_id": "126",
"product_identification_helper": {
"model_numbers": [
"6GK5216-4GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-4C G (6GK5216-4GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)",
"product_id": "127",
"product_identification_helper": {
"model_numbers": [
"6GK5216-4GS00-2TC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)",
"product_id": "128",
"product_identification_helper": {
"model_numbers": [
"6GK5216-4GS00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC216EEC (6GK5216-0BA00-2FC2)",
"product_id": "129",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0BA00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC216EEC (6GK5216-0BA00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC224 (6GK5224-0BA00-2AC2)",
"product_id": "130",
"product_identification_helper": {
"model_numbers": [
"6GK5224-0BA00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC224 (6GK5224-0BA00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)",
"product_id": "131",
"product_identification_helper": {
"model_numbers": [
"6GK5224-4GS00-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC224-4C G (6GK5224-4GS00-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)",
"product_id": "132",
"product_identification_helper": {
"model_numbers": [
"6GK5224-4GS00-2TC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)",
"product_id": "133",
"product_identification_helper": {
"model_numbers": [
"6GK5224-4GS00-2FC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XF204 (6GK5204-0BA00-2GF2)",
"product_id": "134",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2GF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204 (6GK5204-0BA00-2GF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)",
"product_id": "135",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2YF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204 DNA (6GK5204-0BA00-2YF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)",
"product_id": "136",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2AA00-2GF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204-2BA (6GK5204-2AA00-2GF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)",
"product_id": "137",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2AA00-2YF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XM408-4C (6GK5408-4GP00-2AM2)",
"product_id": "138",
"product_identification_helper": {
"model_numbers": [
"6GK5408-4GP00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM408-4C (6GK5408-4GP00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)",
"product_id": "139",
"product_identification_helper": {
"model_numbers": [
"6GK5408-4GQ00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XM408-8C (6GK5408-8GS00-2AM2)",
"product_id": "140",
"product_identification_helper": {
"model_numbers": [
"6GK5408-8GS00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM408-8C (6GK5408-8GS00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)",
"product_id": "141",
"product_identification_helper": {
"model_numbers": [
"6GK5408-8GR00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XM416-4C (6GK5416-4GS00-2AM2)",
"product_id": "142",
"product_identification_helper": {
"model_numbers": [
"6GK5416-4GS00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM416-4C (6GK5416-4GS00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)",
"product_id": "143",
"product_identification_helper": {
"model_numbers": [
"6GK5416-4GR00-2AM2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP208 (6GK5208-0HA00-2AS6)",
"product_id": "144",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0HA00-2AS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208 (6GK5208-0HA00-2AS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)",
"product_id": "145",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0HA00-2TS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP208EEC (6GK5208-0HA00-2ES6)",
"product_id": "146",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0HA00-2ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208EEC (6GK5208-0HA00-2ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)",
"product_id": "147",
"product_identification_helper": {
"model_numbers": [
"6GK5208-0UA00-5ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP216 (6GK5216-0HA00-2AS6)",
"product_id": "148",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0HA00-2AS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216 (6GK5216-0HA00-2AS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)",
"product_id": "149",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0HA00-2TS6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP216EEC (6GK5216-0HA00-2ES6)",
"product_id": "150",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0HA00-2ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216EEC (6GK5216-0HA00-2ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)",
"product_id": "151",
"product_identification_helper": {
"model_numbers": [
"6GK5216-0UA00-5ES6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)",
"product_id": "152",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0BA00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)",
"product_id": "153",
"product_identification_helper": {
"model_numbers": [
"6GK5324-0BA00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)",
"product_id": "154",
"product_identification_helper": {
"model_numbers": [
"6GK5326-2QS00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)",
"product_id": "155",
"product_identification_helper": {
"model_numbers": [
"6GK5326-2QS00-3RR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)",
"product_id": "156",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4FS00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)",
"product_id": "157",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4FS00-2RR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)",
"product_id": "158",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4FS00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)",
"product_id": "159",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4FS00-3RR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)",
"product_id": "160",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4SS00-3AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)",
"product_id": "161",
"product_identification_helper": {
"model_numbers": [
"6GK5328-4SS00-2AR3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)",
"product_id": "162",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GS00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)",
"product_id": "163",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GR00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)",
"product_id": "164",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GS00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)",
"product_id": "165",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GR00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)",
"product_id": "166",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GS00-4AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)",
"product_id": "167",
"product_identification_helper": {
"model_numbers": [
"6GK5524-8GR00-4AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)",
"product_id": "168",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GS00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)",
"product_id": "169",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GR00-3AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)",
"product_id": "170",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GS00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)",
"product_id": "171",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GR00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)",
"product_id": "172",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GS00-4AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)",
"product_id": "173",
"product_identification_helper": {
"model_numbers": [
"6GK5526-8GR00-4AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR528-6M (6GK5528-0AA00-2AR2)",
"product_id": "174",
"product_identification_helper": {
"model_numbers": [
"6GK5528-0AA00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR528-6M (6GK5528-0AA00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)",
"product_id": "175",
"product_identification_helper": {
"model_numbers": [
"6GK5528-0AR00-2HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)",
"product_id": "176",
"product_identification_helper": {
"model_numbers": [
"6GK5528-0AA00-2HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)",
"product_id": "177",
"product_identification_helper": {
"model_numbers": [
"6GK5528-0AR00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR552-12M (6GK5552-0AA00-2AR2)",
"product_id": "178",
"product_identification_helper": {
"model_numbers": [
"6GK5552-0AA00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR552-12M (6GK5552-0AA00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)",
"product_id": "179",
"product_identification_helper": {
"model_numbers": [
"6GK5552-0AR00-2AR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)",
"product_id": "180",
"product_identification_helper": {
"model_numbers": [
"6GK5552-0AA00-2HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6",
"product": {
"name": "SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)",
"product_id": "181",
"product_identification_helper": {
"model_numbers": [
"6GK5552-0AR00-2HR2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)",
"product_id": "182",
"product_identification_helper": {
"model_numbers": [
"6AG1206-2BB00-7AC2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)",
"product_id": "183",
"product_identification_helper": {
"model_numbers": [
"6AG1206-2BS00-7AC2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)",
"product_id": "184",
"product_identification_helper": {
"model_numbers": [
"6AG1208-0BA00-7AC2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c4.4",
"product": {
"name": "SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)",
"product_id": "185",
"product_identification_helper": {
"model_numbers": [
"6AG1216-4BS00-7AC2"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-36323",
"cwe": {
"id": "CWE-74",
"name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88",
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"138",
"139",
"140",
"141",
"142",
"143",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181",
"182",
"183",
"184",
"185"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Apply the principle of least privileges for accounts configured on the affected devices",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88",
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"138",
"139",
"140",
"141",
"142",
"143",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181",
"182",
"183",
"184",
"185"
]
},
{
"category": "mitigation",
"details": "Restrict network access in affected system(s) to ports 80/TCP and 443/TCP to trusted IP addresses and personal only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88",
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"138",
"139",
"140",
"141",
"142",
"143",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181",
"182",
"183",
"184",
"185"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"25",
"26",
"27",
"28",
"29",
"30"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.0.0 or later version",
"product_ids": [
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/"
},
{
"category": "vendor_fix",
"details": "Update to V2.3.1 or later version",
"product_ids": [
"19",
"20"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109810992/"
},
{
"category": "vendor_fix",
"details": "Update to V4.4 or later version",
"product_ids": [
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"182",
"183",
"184",
"185"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817768/"
},
{
"category": "vendor_fix",
"details": "Update to V6.6 or later version",
"product_ids": [
"138",
"139",
"140",
"141",
"142",
"143",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818003/"
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
},
{
"category": "vendor_fix",
"details": "Update to V7.1.2 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109813051/"
},
{
"category": "vendor_fix",
"details": "Update to V2.3.1 or later version",
"product_ids": [
"21",
"22",
"23",
"24"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88",
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"138",
"139",
"140",
"141",
"142",
"143",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181",
"182",
"183",
"184",
"185"
]
}
],
"title": "CVE-2022-36323"
},
{
"cve": "CVE-2022-36324",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88",
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"138",
"139",
"140",
"141",
"142",
"143",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181",
"182",
"183",
"184",
"185"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Apply the principle of least privileges for accounts configured on the affected devices",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88",
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"138",
"139",
"140",
"141",
"142",
"143",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181",
"182",
"183",
"184",
"185"
]
},
{
"category": "mitigation",
"details": "Restrict network access in affected system(s) to ports 80/TCP and 443/TCP to trusted IP addresses and personal only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88",
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"138",
"139",
"140",
"141",
"142",
"143",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181",
"182",
"183",
"184",
"185"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"25",
"26",
"27",
"28",
"29",
"30"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.0.0 or later version",
"product_ids": [
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/"
},
{
"category": "vendor_fix",
"details": "Update to V2.3.1 or later version",
"product_ids": [
"19",
"20",
"21",
"22",
"23",
"24"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109810992/"
},
{
"category": "vendor_fix",
"details": "Update to V4.4 or later version",
"product_ids": [
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"182",
"183",
"184",
"185"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817768/"
},
{
"category": "vendor_fix",
"details": "Update to V6.6 or later version",
"product_ids": [
"138",
"139",
"140",
"141",
"142",
"143",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818003/"
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
},
{
"category": "vendor_fix",
"details": "Update to V7.1.2 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109813051/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88",
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"138",
"139",
"140",
"141",
"142",
"143",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181",
"182",
"183",
"184",
"185"
]
}
],
"title": "CVE-2022-36324"
},
{
"cve": "CVE-2022-36325",
"cwe": {
"id": "CWE-80",
"name": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88",
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"138",
"139",
"140",
"141",
"142",
"143",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181",
"182",
"183",
"184",
"185"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Apply the principle of least privileges for accounts configured on the affected devices",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88",
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"138",
"139",
"140",
"141",
"142",
"143",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181",
"182",
"183",
"184",
"185"
]
},
{
"category": "mitigation",
"details": "Restrict network access in affected system(s) to ports 80/TCP and 443/TCP to trusted IP addresses and personal only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88",
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"138",
"139",
"140",
"141",
"142",
"143",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181",
"182",
"183",
"184",
"185"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"25",
"26",
"27",
"28",
"29",
"30"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.0.0 or later version",
"product_ids": [
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109815650/"
},
{
"category": "vendor_fix",
"details": "Update to V2.3.1 or later version",
"product_ids": [
"19",
"20"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109810992/"
},
{
"category": "vendor_fix",
"details": "Update to V4.4 or later version",
"product_ids": [
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"182",
"183",
"184",
"185"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817768/"
},
{
"category": "vendor_fix",
"details": "Update to V6.6 or later version",
"product_ids": [
"138",
"139",
"140",
"141",
"142",
"143",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818003/"
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
},
{
"category": "vendor_fix",
"details": "Update to V7.1.2 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109813051/"
},
{
"category": "vendor_fix",
"details": "Update to V2.3.1 or later version",
"product_ids": [
"21",
"22",
"23",
"24"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82",
"83",
"84",
"85",
"86",
"87",
"88",
"89",
"90",
"91",
"92",
"93",
"94",
"95",
"96",
"97",
"98",
"99",
"100",
"101",
"102",
"103",
"104",
"105",
"106",
"107",
"108",
"109",
"110",
"111",
"112",
"113",
"114",
"115",
"116",
"117",
"118",
"119",
"120",
"121",
"122",
"123",
"124",
"125",
"126",
"127",
"128",
"129",
"130",
"131",
"132",
"133",
"134",
"135",
"136",
"137",
"138",
"139",
"140",
"141",
"142",
"143",
"144",
"145",
"146",
"147",
"148",
"149",
"150",
"151",
"152",
"153",
"154",
"155",
"156",
"157",
"158",
"159",
"160",
"161",
"162",
"163",
"164",
"165",
"166",
"167",
"168",
"169",
"170",
"171",
"172",
"173",
"174",
"175",
"176",
"177",
"178",
"179",
"180",
"181",
"182",
"183",
"184",
"185"
]
}
],
"title": "CVE-2022-36325"
}
]
}
SSA-019200
Vulnerability from csaf_siemens - Published: 2026-04-14 00:00 - Updated: 2026-04-14 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)
|
6GK5721-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
Siemens / SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)
|
6GK5721-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)
|
6GK5722-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)
|
6GK5722-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
Siemens / SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)
|
6GK5722-1FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)
|
6GK5734-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)
|
6GK5734-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
Siemens / SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)
|
6GK5734-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
Siemens / SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)
|
6GK5734-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)
|
6GK5738-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
Siemens / SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)
|
6GK5738-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)
|
6GK5748-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
Siemens / SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)
|
6GK5748-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)
|
6GK5748-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
Siemens / SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)
|
6GK5748-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)
|
6GK5761-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
Siemens / SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)
|
6GK5761-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)
|
6GK5774-1FY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
Siemens / SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)
|
6GK5774-1FY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)
|
6GK5774-1FX00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)
|
6GK5774-1FX00-0AA6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)
|
6GK5774-1FX00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
Siemens / SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)
|
6GK5774-1FX00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
Siemens / SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)
|
6GK5774-1FX00-0AB6
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)
|
6GK5778-1GY00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
Siemens / SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)
|
6GK5778-1GY00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
Siemens / SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)
|
6GK5778-1GY00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
Siemens / SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)
|
6GK5778-1GY00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)
|
6GK5786-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
Siemens / SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)
|
6GK5786-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)
|
6GK5786-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)
|
6GK5786-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
Siemens / SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)
|
6GK5786-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)
|
6GK5786-2FE00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
Siemens / SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)
|
6GK5786-2FE00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)
|
6GK5786-2HC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
Siemens / SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)
|
6GK5786-2HC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)
|
6GK5788-1GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
Siemens / SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)
|
6GK5788-1GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)
|
6GK5788-1FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
Siemens / SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)
|
6GK5788-1FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)
|
6GK5788-2GD00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
Siemens / SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)
|
6GK5788-2GD00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)
|
6GK5788-2GD00-0TA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)
|
6GK5788-2GD00-0TB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
Siemens / SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)
|
6GK5788-2GD00-0TC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)
|
6GK5788-2FC00-0AA0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)
|
6GK5788-2FC00-0AB0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
|
SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
Siemens / SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)
|
6GK5788-2FC00-0AC0
|
vers:intdot/<6.6.0 |
Vendor Fix
fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "SCALANCE W-700 IEEE 802.11n family before V6.6.0 are affected by multiple vulnerabilities.\n\nSiemens has released a new version for SCALANCE W-700 IEEE 802.11n family and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-019200: Multiple Vulnerabilities in SCALANCE W-700 IEEE 802.11n Devices Before V6.6.0 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-019200.html"
},
{
"category": "self",
"summary": "SSA-019200: Multiple Vulnerabilities in SCALANCE W-700 IEEE 802.11n Devices Before V6.6.0 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-019200.json"
}
],
"title": "SSA-019200: Multiple Vulnerabilities in SCALANCE W-700 IEEE 802.11n Devices Before V6.6.0",
"tracking": {
"current_release_date": "2026-04-14T00:00:00.000Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-019200",
"initial_release_date": "2026-04-14T00:00:00.000Z",
"revision_history": [
{
"date": "2026-04-14T00:00:00.000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"6GK5721-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)",
"product_id": "2",
"product_identification_helper": {
"model_numbers": [
"6GK5721-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)",
"product_id": "3",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)",
"product_id": "4",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)",
"product_id": "5",
"product_identification_helper": {
"model_numbers": [
"6GK5722-1FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)",
"product_id": "6",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)",
"product_id": "7",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)",
"product_id": "8",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)",
"product_id": "9",
"product_identification_helper": {
"model_numbers": [
"6GK5734-1FX00-0AB6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)",
"product_id": "10",
"product_identification_helper": {
"model_numbers": [
"6GK5738-1GY00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)",
"product_id": "11",
"product_identification_helper": {
"model_numbers": [
"6GK5738-1GY00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)",
"product_id": "12",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)",
"product_id": "13",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)",
"product_id": "14",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)",
"product_id": "15",
"product_identification_helper": {
"model_numbers": [
"6GK5748-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)",
"product_id": "16",
"product_identification_helper": {
"model_numbers": [
"6GK5761-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)",
"product_id": "17",
"product_identification_helper": {
"model_numbers": [
"6GK5761-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)",
"product_id": "18",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FY00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)",
"product_id": "19",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FY00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)",
"product_id": "20",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)",
"product_id": "21",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)",
"product_id": "22",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)",
"product_id": "23",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)",
"product_id": "24",
"product_identification_helper": {
"model_numbers": [
"6GK5774-1FX00-0AB6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)",
"product_id": "25",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)",
"product_id": "26",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)",
"product_id": "27",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)",
"product_id": "28",
"product_identification_helper": {
"model_numbers": [
"6GK5778-1GY00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)",
"product_id": "29",
"product_identification_helper": {
"model_numbers": [
"6GK5786-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)",
"product_id": "30",
"product_identification_helper": {
"model_numbers": [
"6GK5786-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)",
"product_id": "31",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)",
"product_id": "32",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)",
"product_id": "33",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)",
"product_id": "34",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FE00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)",
"product_id": "35",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2FE00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)",
"product_id": "36",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2HC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)",
"product_id": "37",
"product_identification_helper": {
"model_numbers": [
"6GK5786-2HC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)",
"product_id": "38",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)",
"product_id": "39",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)",
"product_id": "40",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)",
"product_id": "41",
"product_identification_helper": {
"model_numbers": [
"6GK5788-1FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)",
"product_id": "42",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)",
"product_id": "43",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)",
"product_id": "44",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)",
"product_id": "45",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)",
"product_id": "46",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2GD00-0TC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)",
"product_id": "47",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)",
"product_id": "48",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.6.0",
"product": {
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)",
"product_id": "49",
"product_identification_helper": {
"model_numbers": [
"6GK5788-2FC00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-24588",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "summary",
"text": "The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn\u0027t require that the A-MSDU flag in the plaintext QoS header field is authenticated. Against devices that support receiving non-SSP A-MSDU frames (which is mandatory as part of 802.11n), an adversary can abuse this to inject arbitrary network packets.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
{
"category": "mitigation",
"details": "Disable A-MSDU, if possible",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2020-24588"
},
{
"cve": "CVE-2020-26139",
"cwe": {
"id": "CWE-287",
"name": "Improper Authentication"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the kernel in NetBSD 7.1. An Access Point (AP) forwards EAPOL frames to other clients even though the sender has not yet successfully authenticated to the AP. This might be abused in projected Wi-Fi networks to launch denial-of-service attacks against connected clients and makes it easier to exploit other vulnerabilities in connected clients.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2020-26139"
},
{
"cve": "CVE-2020-26140",
"cwe": {
"id": "CWE-74",
"name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2020-26140"
},
{
"cve": "CVE-2020-26141",
"cwe": {
"id": "CWE-354",
"name": "Improper Validation of Integrity Check Value"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The Wi-Fi implementation does not verify the Message Integrity Check (authenticity) of fragmented TKIP frames. An adversary can abuse this to inject and possibly decrypt packets in WPA or WPA2 networks that support the TKIP data-confidentiality protocol.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2020-26141"
},
{
"cve": "CVE-2020-26143",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the ALFA Windows 10 driver 1030.36.604 for AWUS036ACH. The WEP, WPA, WPA2, and WPA3 implementations accept fragmented plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2020-26143"
},
{
"cve": "CVE-2020-26144",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext A-MSDU frames as long as the first 8 bytes correspond to a valid RFC1042 (i.e., LLC/SNAP) header for EAPOL. An adversary can abuse this to inject arbitrary network packets independent of the network configuration.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2020-26144"
},
{
"cve": "CVE-2020-26146",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WPA, WPA2, and WPA3 implementations reassemble fragments with non-consecutive packet numbers. An adversary can abuse this to exfiltrate selected fragments. This vulnerability is exploitable when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used. Note that WEP is vulnerable to this attack by design.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2020-26146"
},
{
"cve": "CVE-2020-26147",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in the Linux kernel 5.8.9. The WEP, WPA, WPA2, and WPA3 implementations reassemble fragments even though some of them were sent in plaintext. This vulnerability can be abused to inject packets and/or exfiltrate selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "mitigation",
"details": "As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:N",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2020-26147"
},
{
"cve": "CVE-2021-3712",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "ASN.1 strings are represented internally within OpenSSL as an ASN1_STRING structure which contains a buffer holding the string data and a field holding the buffer length. This contrasts with normal C strings which are repesented as a buffer for the string data which is terminated with a NUL (0) byte. Although not a strict requirement, ASN.1 strings that are parsed using OpenSSL\u0027s own \"d2i\" functions (and other similar parsing functions) as well as any string whose value has been set with the ASN1_STRING_set() function will additionally NUL terminate the byte array in the ASN1_STRING structure. However, it is possible for applications to directly construct valid ASN1_STRING structures which do not NUL terminate the byte array by directly setting the \"data\" and \"length\" fields in the ASN1_STRING array. This can also happen by using the ASN1_STRING_set0() function. Numerous OpenSSL functions that print ASN.1 data have been found to assume that the ASN1_STRING byte array will be NUL terminated, even though this is not guaranteed for strings that have been directly constructed. Where an application requests an ASN.1 structure to be printed, and where that ASN.1 structure contains ASN1_STRINGs that have been directly constructed by the application without NUL terminating the \"data\" field, then a read buffer overrun can occur. The same thing can also occur during name constraints processing of certificates (for example if a certificate has been directly constructed by the application instead of loading it via the OpenSSL parsing functions, and the certificate contains non NUL terminated ASN1_STRING structures). It can also occur in the X509_get1_email(), X509_REQ_get1_email() and X509_get1_ocsp() functions. If a malicious actor can cause an application to directly construct an ASN1_STRING and then process it through one of the affected OpenSSL functions then this issue could be hit. This might result in a crash (causing a Denial of Service attack). It could also result in the disclosure of private memory contents (such as private keys, or sensitive plaintext). Fixed in OpenSSL 1.1.1l (Affected 1.1.1-1.1.1k). Fixed in OpenSSL 1.0.2za (Affected 1.0.2-1.0.2y).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2021-3712"
},
{
"cve": "CVE-2022-0778",
"cwe": {
"id": "CWE-835",
"name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The BN_mod_sqrt() function in openSSL, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2022-0778"
},
{
"cve": "CVE-2022-31765",
"cwe": {
"id": "CWE-862",
"name": "Missing Authorization"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly authorize the change password function of the web interface.\r\nThis could allow low privileged users to escalate their privileges.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2022-31765"
},
{
"cve": "CVE-2022-36323",
"cwe": {
"id": "CWE-74",
"name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2022-36323"
},
{
"cve": "CVE-2022-36324",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2022-36324"
},
{
"cve": "CVE-2022-36325",
"cwe": {
"id": "CWE-80",
"name": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2022-36325"
},
{
"cve": "CVE-2023-44373",
"cwe": {
"id": "CWE-74",
"name": "Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V6.6.0 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109996102/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49"
]
}
],
"title": "CVE-2023-44373"
}
]
}
FKIE_CVE-2022-36324
Vulnerability from fkie_nvd - Published: 2022-08-10 12:15 - Updated: 2026-04-14 09:167.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A43ECBDD-F831-4364-8869-C696D1AC531A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6EF65A06-2222-47D2-83B5-4C61E6D8731E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ax_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "23DDDAEC-C0B4-4E14-9840-101B6F24DBE5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ax:-:*:*:*:*:*:*:*",
"matchCriteriaId": "09908B6A-6655-42F0-A20B-79FFBF81937A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F05D6764-79B4-4787-B2D2-E685910453C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:*",
"matchCriteriaId": "880644DA-9280-4498-AD72-5CBD59CC8142",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ac_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8D7CF655-D174-4CE8-A2AC-C14967A8283B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ac:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C93984BD-70E6-496C-BA20-18464B0E84B3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E673B450-C436-49F3-B2F3-872B704FE075",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8CB0BE85-4A96-45EB-9EAA-A2D9E5D45508",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B9F9F101-6042-4D11-98CE-16A996023B38",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D9E6A2AB-7F15-4ABB-B00A-F5667B615ABE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
"matchCriteriaId": "18DC9125-FC41-4BAB-9638-C42DEF40235B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "713ADE75-1915-4DBB-9FC3-59E9A03AB5A8",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5C19D54A-8070-4EC6-9B30-B1B04A8BDABD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D0113244-9647-4E95-B1E4-DBD26ADD3786",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1FF67A06-D93B-4E4E-A639-29E0E49654FE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "692B60D5-696D-4680-BB38-3C0EC0F2D034",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D83C08F3-C6F7-46D1-B3F6-0173F9B7E983",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
"matchCriteriaId": "72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C08F92C8-0A5D-470E-8CFC-F622C3014336",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1C93B717-35A4-4824-9B85-DB046E38DA33",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "49C5CBD8-9799-4EBA-8297-EAE04F43DDD5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4F02CFE9-6058-4B0D-9FD5-6C84ED4A3EAD",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
"matchCriteriaId": "39310380-7D17-46C5-B91A-DFDF602D56A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C4EA7C54-4200-4E33-B2EA-0F82AA3ECD9D",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0C21EC27-F0A8-4DCA-88AD-92D07477B5AD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4B9CA045-5DB1-422C-ABE2-AC89F5A27847",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CC286693-55D6-4949-8164-262EB6C022C9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81AD4EB0-A125-4E4B-9348-AA6E670061B2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BC7B235D-0141-46E5-9057-2203555AE58A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "82708B62-47F9-4909-A52C-D96BC3AA567D",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "CB6B6ED1-7057-4240-B1C9-660173BF1A6A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49EBEDA9-A826-45DD-A5BB-D5B55FB47B60",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F7D1CCD-4DFD-4037-9BDC-65466D639456",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "822CB559-BAFC-4674-A64B-BDCF1AAFDD0E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "316A0742-A32F-453E-922A-F084D9BEAA19",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B6550B2D-4B8E-414C-B4CB-7B12D6D4EA4A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "62C9A709-2AB4-4836-B925-988D78AEB278",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8E922B78-7951-4115-8985-D824F6DDE41B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "17E1B7ED-A272-43C6-9CA5-4CF370F8ED1C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "62852B4B-AF5A-4967-AFC2-14CEC2F6972C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1ABF1FC1-2FB5-42D8-867C-0B93AB67C096",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9CCF0CEF-2E48-472E-9BDE-6E63F4CEA467",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "429647B3-1C26-42EF-94DC-B9630AA627CD",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
"matchCriteriaId": "585424EB-F9AB-45FB-B5C5-78FE45E3341A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D2F04D78-74F0-4471-9AF6-54EA822F1992",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4ABC0D8D-4F32-487F-835C-DADAB647EC21",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "00C80C92-FC92-4B96-8B80-6F7E0B07EBAD",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7668BC0B-A47A-4E05-9933-51CD43F3B7BA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AA3B23C3-8880-4640-A6B2-EA870A85AAFE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "78645734-50C1-4331-9FC4-AC8A8679B6AF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B2765D0D-9A77-45E5-9F58-BF877E6F94B7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "22B8B758-9781-474E-93C3-17DDDF263CC2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09F27730-5DB8-4736-B6ED-A46C3888F48D",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "323CEAEA-8122-43A5-BB87-97C7133FF510",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A5A04F9F-133C-4C02-BA65-CABA47E1F329",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6BE498F8-A9D8-4A92-90CE-21BA30234947",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2EA0205D-A280-4903-927A-AC4FEC051E2A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
"matchCriteriaId": "39AB9EB3-0F05-41C2-A32F-27B6D0C9C039",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CFF36832-3023-4AEA-800E-ED4D87271E3A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E7806CF9-4DA5-4090-84BD-D098C5FB1178",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "33C3BB4B-63C9-4770-9CC0-053A0B655ED7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "EE4E3630-DB15-46EA-B320-E4E457240B9F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D9089DA8-FEF8-4927-B56A-139B67571671",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "34F19168-C521-4D67-BF88-1551F079859E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
"matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A6C7A93D-B629-4A56-B961-5D4FD012E6E6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FAF28152-D6CA-4D20-BDF1-1EF4B7D10429",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4F316894-3BBB-4B72-8636-23868BF557AB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
"matchCriteriaId": "99E6AFAA-B903-47BB-B0F3-7650B039C0FB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6BF5436-1BCB-4945-8F2D-68F766D3567F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9FC408A8-903F-43A2-9D05-65AD4482FDBB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "813D5C37-C5CF-4B50-920A-38C9CF042966",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2AA81823-013F-4990-B62D-86C404F04BCB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0DFCB811-4CE6-4FA9-A722-86ED0D434FD9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2FB222B-0414-4A1E-8BBD-6470CDB3BFF8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "24722F13-7DA7-4CA6-A141-293DE72B15B4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7096DBA5-95BB-44D7-B7CA-B1845C87F70E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CFE568ED-3604-428E-82E7-4027CB2DDD62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "78562689-B494-4500-9725-B418F1EC3CAB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "616BB0A9-47FB-4F72-8241-0ADF50E6E236",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F9102A41-5812-4014-BC07-E571E815ED49",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "04B56011-74F9-4760-A4AD-850F0CCF0B62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "86A2A766-9046-484F-9D49-4A1F4F0F96A4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3491A486-47F3-4B30-B613-DCC412F6EF5B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "54BB088B-67FC-4C34-98A0-EC05B67B2396",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
"matchCriteriaId": "24C7FB09-D247-48F0-B87C-6A478BDC0A5A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BF3C7B31-25AA-4D74-AB2D-5C7F1D8025C1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "17BD41C2-2398-4A03-9C5F-43AEF424261E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DCFA1A9B-1130-46BC-9A5F-FFBB527517FF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2B313A4C-D3E7-4964-BA51-3401546B36C5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E5AAC31E-42DE-423E-8F43-A5600E24160F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D6E888EA-73A7-42B8-A617-621CF192F2A9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7D5F9D33-F74A-4FFB-9327-5CE691F0C1D6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
"matchCriteriaId": "67E4D039-5BF8-469B-A6FE-A391A6D1BDA4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7E0BC528-5B72-48AB-A70A-B116770A8587",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "33D044BD-12AD-42C9-B01C-957BEC6C6790",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "18D7E470-D872-4C37-8669-B66328F173D6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "12512EC4-FB7D-420F-9A8A-547562BE1B49",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F51CE85F-16D1-4E49-83C7-70C90233E294",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B357AD42-1806-4BE5-B76D-F798E475F659",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "889CF2C0-EE6C-447F-85F1-005730EAD232",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr-300eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "17115730-97BF-473F-A4A7-03D5AE0F1A6D",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6FF41E9F-4627-49EE-BCF1-08B5AADE964A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr-300poe_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "18537338-DF5C-4F7A-995E-7F953B380657",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CC118867-1A6C-4C3B-AD75-5D24551DB0BC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "64A47C63-7150-4F8D-BFD9-2F5C2761DBDF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
"matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0AC751E0-FC87-4DEB-85E8-C3E028B76482",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
"matchCriteriaId": "36C9AE74-4683-4ED0-A605-3A6B065C230E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EB09860F-9DC8-476B-9AF7-6FFE57101D6C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4356417E-B4CB-45B0-B395-CE9D423FAB44",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1E6AB4BE-D669-4A95-8F8A-F2DA146D5FB1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F952542-6B79-4681-A236-15C188AAEB1E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1F4B8E2B-DEFF-4F1C-B5A4-0C4671C605C1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
"matchCriteriaId": "664D9C76-BC13-4874-939C-A8211DA33903",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9F4DE2B7-1AB3-4BA5-B261-926B774B01DD",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4834A67B-7B0B-4F88-BBFB-25667FD68EC5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr324wg_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "82D18854-D803-40C6-BB14-A28594C37CDB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E767C461-8FA6-4700-98CB-734AFD309140",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr326-2c_poe_wg_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4B7EC611-120E-4002-BF1E-4B45E431B7FC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr326-2c_poe_wg:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CBD19EFB-12D2-4401-B87A-91873528E474",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AFA83BBC-C6F3-4F98-A92B-2611EACBC093",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A5B7DEDC-66BD-4701-BBDD-16273263ADC9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FC8637DA-CA1E-46C6-AD1D-4F90B2A0BB35",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "080E722F-FCD4-4967-86EE-151ADC5702E7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BA8C39A2-1989-49ED-91FC-7BCE7002F250",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7DEEA300-16C3-4FEE-88A8-674DE2AEEC95",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BA970560-8AE2-49B1-BCD0-E7913DEA50ED",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AC7CB42C-666C-4DFD-B3CB-DD9509363E94",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A1509C8A-89FC-445D-BB22-BF9A811E853B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8709D27F-90B9-4AF8-8784-E974CE859518",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:*",
"matchCriteriaId": "756A07F8-4F9F-4A76-942E-82CB92216943",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "554455C1-19FF-4F71-BC36-13DDE7FE0087",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "10F66ADC-91EC-4ED0-B768-03F94241B300",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0921AD23-44BA-4F5C-9DC8-A5F90753C977",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F41F6AE6-0E43-4D12-B379-FCF3A2A104DB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FDE5E54D-FFED-4C2C-B89D-E085E61D44E4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B0630BF0-8EFD-425A-A371-E1B0E5074D4D",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DEAA4C6F-F234-4895-9D0D-B89E3F07F038",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "03DFEC43-5E84-460A-A50E-6BF378E83A70",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "64CCA458-1F7F-44ED-ACD5-E9355B112194",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2_l3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FD9EACF0-ECE5-40DD-8280-41707A637E9E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_l3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7B7870B9-F1CF-4503-A64C-6258FFB9D78D",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr528-6m_l3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "81355370-BE69-434F-ABAC-8611F9909E46",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7319A333-EAA2-4ED2-A814-1AAEDFAC4E04",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AB16A0BE-5AF3-4168-B755-D023E497A35F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B490BBD4-458F-4077-8404-9208499226E7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*",
"matchCriteriaId": "09743616-31C9-4E47-8A4A-B15D76204BE7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "87B35693-9D07-4507-8070-43B8F756F772",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4A806691-3F4B-46AA-9718-2F6BF0FD3D7A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B05DE63D-186B-46CC-B3CE-66923F290B6B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C97B2B53-F40E-4FB1-B3BA-5D0E0F8501F0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EF61A53B-E4AD-4379-B053-1A25FDF65BD0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2_l3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BA9921B1-38FD-4404-9986-3023C577FE5C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack."
},
{
"lang": "es",
"value": "Los dispositivos afectados no manejan adecuadamente la renegociaci\u00f3n de los par\u00e1metros SSL/TLS. Esto podr\u00eda permitir a un atacante remoto no autenticado eludir la prevenci\u00f3n de fuerza bruta de TCP y provocar una condici\u00f3n de denegaci\u00f3n de servicio mientras dure el ataque"
}
],
"id": "CVE-2022-36324",
"lastModified": "2026-04-14T09:16:30.903",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-08-10T12:15:12.930",
"references": [
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-019200.html"
},
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html"
},
{
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-770"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-770"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
VAR-202208-0610
Vulnerability from variot - Updated: 2023-12-18 12:15Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack. SCALANCE M-800 firmware, SCALANCE S615 firmware, scalance w700 ieee 802.11ax Multiple Siemens products, including firmware, contain vulnerabilities related to limited or unthrottled resource allocation.Service operation interruption (DoS) It may be in a state. The SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 industrial routers are used for secure remote access to plants via mobile networks (e.g. GPRS or UMTS) and have integrated security functions for firewalls to prevent unauthorized access, as well as VPN to Secure data transmission. SCALANCE SC-600 devices (SC622-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) are used to protect trusted industrial networks from untrusted network attacks. They allow filtering incoming and outgoing network connections in different ways. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. SCALANCE W-700 products are wireless communication devices based on the IEEE 802.11ax standard. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions)
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-0610",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "scalance xc206-2sfp g",
"scope": null,
"trust": 1.6,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xc224",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr324wg",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc208g poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xp216eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr324-4m eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr528-6m 2hr2",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr524",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xf-200ba",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr524-8c l3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xb205-3ld",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr-300poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance s615",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr552-12",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc206-2sfp g",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr324-12m ts",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xm408-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc216-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr528-6m l3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xm408-4c l3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr528-6m",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc216-4c g \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc216-4c g eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc-200",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr524-8c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xb213-3ld",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w700 ieee 802.11n",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc224-4c g",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xp216",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc208g \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xb-200",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w700 ieee 802.11ax",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xb208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr-300",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xm416-4c l3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc206-2g poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr552-12m 2hr2 l3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr552",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xp208",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc216eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr552-12m",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xm408-8c l3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc216-4c g",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc208g eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr526-8c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xb213-3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr528",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc208g",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr500",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr324-4m poe ts",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc206-2sfp g eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr528-6m 2hr2 l3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr526-8c l3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc224-4c g \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xm416-4c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc206-2",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc216",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xp-200",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr326-2c poe wg",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xf204-2ba dna",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xp216poe eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance w700 ieee 802.11ac",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xm400",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xp208poe eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr-300wg",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr526",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xp208 \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr324-12m",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xm408-8c",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xb205-3",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc224-4c g eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xf204-2ba irt",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xp208eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc206-2sfp g \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr-300eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr328-4c wg",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance m-800",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc206-2sfp eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc208eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xp216 \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xb216",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xc206-2g poe eec",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr324-4m poe",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xr552-12m 2hr2",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "scalance xb205-3",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xc206-2",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xb-200",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xb216",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance w700 ieee 802.11ax",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xc-200",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xc206-2sfp g eec",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m-800",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xb213-3ld",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xb213-3",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xc206-2g poe eec",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance w700 ieee 802.11n",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance w700 ieee 802.11ac",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xb205-3ld",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance s615",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xc206-2sfp eec",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xb208",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xc206-2g poe",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance m-800 s615",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "/"
},
{
"model": "scalance w-700 ieee 802.11ax family",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w-700 ieee 802.11n family",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "scalance w-1700 ieee 802.11ac family",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xb-200 switch family",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xc-200 switch family",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xf-200ba switch family",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xm-400 family",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xp-200 switch family",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr-300wg switch family",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "scalance xr-500 family",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-56475"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014932"
},
{
"db": "NVD",
"id": "CVE-2022-36324"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ax_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ax:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ac_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ac:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr-300eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr-300poe_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324wg_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr326-2c_poe_wg_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr326-2c_poe_wg:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr528-6m_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr528-6m_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr552-12m_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2_l3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-36324"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens has reported these vulnerabilities to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2714"
}
],
"trust": 0.6
},
"cve": "CVE-2022-36324",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-56475",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-36324",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-36324",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2022-36324",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2022-56475",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-2714",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-56475"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014932"
},
{
"db": "NVD",
"id": "CVE-2022-36324"
},
{
"db": "NVD",
"id": "CVE-2022-36324"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2714"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack. SCALANCE M-800 firmware, SCALANCE S615 firmware, scalance w700 ieee 802.11ax Multiple Siemens products, including firmware, contain vulnerabilities related to limited or unthrottled resource allocation.Service operation interruption (DoS) It may be in a state. The SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 industrial routers are used for secure remote access to plants via mobile networks (e.g. GPRS or UMTS) and have integrated security functions for firewalls to prevent unauthorized access, as well as VPN to Secure data transmission. SCALANCE SC-600 devices (SC622-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) are used to protect trusted industrial networks from untrusted network attacks. They allow filtering incoming and outgoing network connections in different ways. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. SCALANCE W-700 products are wireless communication devices based on the IEEE 802.11ax standard. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions)",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-36324"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014932"
},
{
"db": "CNVD",
"id": "CNVD-2022-56475"
},
{
"db": "VULMON",
"id": "CVE-2022-36324"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-36324",
"trust": 3.9
},
{
"db": "SIEMENS",
"id": "SSA-710008",
"trust": 3.1
},
{
"db": "ICS CERT",
"id": "ICSA-22-223-07",
"trust": 1.5
},
{
"db": "JVN",
"id": "JVNVU90767165",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014932",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-56475",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2022.4032",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2714",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-36324",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-56475"
},
{
"db": "VULMON",
"id": "CVE-2022-36324"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014932"
},
{
"db": "NVD",
"id": "CVE-2022-36324"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2714"
}
]
},
"id": "VAR-202208-0610",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-56475"
}
],
"trust": 1.2503125066666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-56475"
}
]
},
"last_update_date": "2023-12-18T12:15:23.837000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Unknown Vulnerability in Siemens SCALANCE Products",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/343621"
},
{
"title": "Multiple Siemens SCALANCE Product security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=207453"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-56475"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2714"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-770",
"trust": 1.0
},
{
"problemtype": "Allocation of resources without limits or throttling (CWE-770) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014932"
},
{
"db": "NVD",
"id": "CVE-2022-36324"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu90767165/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-36324"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-07"
},
{
"trust": 0.6,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2022.4032"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-36324/"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-223-07"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/770.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-07"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-56475"
},
{
"db": "VULMON",
"id": "CVE-2022-36324"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014932"
},
{
"db": "NVD",
"id": "CVE-2022-36324"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2714"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-56475"
},
{
"db": "VULMON",
"id": "CVE-2022-36324"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014932"
},
{
"db": "NVD",
"id": "CVE-2022-36324"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2714"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-08-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-56475"
},
{
"date": "2022-08-10T00:00:00",
"db": "VULMON",
"id": "CVE-2022-36324"
},
{
"date": "2023-09-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-014932"
},
{
"date": "2022-08-10T12:15:12.930000",
"db": "NVD",
"id": "CVE-2022-36324"
},
{
"date": "2022-08-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2714"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-08-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-56475"
},
{
"date": "2022-08-10T00:00:00",
"db": "VULMON",
"id": "CVE-2022-36324"
},
{
"date": "2023-09-22T08:25:00",
"db": "JVNDB",
"id": "JVNDB-2022-014932"
},
{
"date": "2023-02-23T16:19:42.137000",
"db": "NVD",
"id": "CVE-2022-36324"
},
{
"date": "2022-09-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2714"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2714"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vulnerability in limiting or non-slotting resource allocation in multiple Siemens products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014932"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2714"
}
],
"trust": 0.6
}
}
GHSA-HM3H-QVM3-R8QV
Vulnerability from github – Published: 2022-08-11 00:00 – Updated: 2026-04-14 09:30A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions). Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.
{
"affected": [],
"aliases": [
"CVE-2022-36324"
],
"database_specific": {
"cwe_ids": [
"CWE-770"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2022-08-10T12:15:00Z",
"severity": "HIGH"
},
"details": "A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions). Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.",
"id": "GHSA-hm3h-qvm3-r8qv",
"modified": "2026-04-14T09:30:41Z",
"published": "2022-08-11T00:00:42Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-36324"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-019200.html"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.