cve-2022-30792
Vulnerability from cvelistv5
Published
2022-07-11 10:40
Modified
2024-09-16 23:05
Severity ?
EPSS score ?
Summary
In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:03:38.599Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Gateway", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Windows", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Development System V3", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.10", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Embedded Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Remote Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for Beckhoff CX9020 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Linux", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] } ], "datePublic": "2022-07-08T00:00:00", "descriptions": [ { "lang": "en", "value": "In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400 Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-11T10:40:43", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=" } ], "source": { "defect": [ "CERT@VDE#", "64130" ], "discovery": "UNKNOWN" }, "title": "CODESYS: CmpChannelServer, CmpChannelServerEmbedded allow unauthenticated attackers to block all their available communication channels", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-07-08T06:00:00.000Z", "ID": "CVE-2022-30792", "STATE": "PUBLIC", "TITLE": "CODESYS: CmpChannelServer, CmpChannelServerEmbedded allow unauthenticated attackers to block all their available communication channels" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Control RTE (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Control RTE (for Beckhoff CX) SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Control Win (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Gateway", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Edge Gateway for Windows", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS HMI (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Development System V3", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.10" } ] } }, { "product_name": "CODESYS Control Runtime System Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Embedded Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Remote Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Control for BeagleBone SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Beckhoff CX9020 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for IOT2000 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Linux SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC100 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC200 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PLCnext SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Raspberry Pi SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Edge Gateway for Linux", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400 Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=", "refsource": "CONFIRM", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=" } ] }, "source": { "defect": [ "CERT@VDE#", "64130" ], "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-30792", "datePublished": "2022-07-11T10:40:43.935648Z", "dateReserved": "2022-05-16T00:00:00", "dateUpdated": "2024-09-16T23:05:31.037Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-30792\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2022-07-11T11:15:08.240\",\"lastModified\":\"2024-11-21T07:03:23.950\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected.\"},{\"lang\":\"es\",\"value\":\"En CmpChannelServer de CODESYS versi\u00f3n V3 en m\u00faltiples versiones un consumo no controlado de recursos permite a un atacante no autorizado bloquear nuevas conexiones de canales de comunicaci\u00f3n. Las conexiones existentes no est\u00e1n afectadas\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"B5D6E827-7AD1-4248-82E6-C879771A2FBA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_empc-a\\\\/imx6:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"E07464D3-D8E5-45CC-8703-B445A866F015\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.6.0.0\",\"matchCriteriaId\":\"AD1474A7-A282-4929-A9E4-721322DCAE15\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"AB585AB5-D0AC-46DC-9723-A0FEFBFB015C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"4F6E2A1D-0187-4C71-A87D-48B3EC3D99DD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"A78E493B-6D9E-4196-830C-24BCF25D3D44\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_plcnext:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.6.0.0\",\"matchCriteriaId\":\"BD0BCA34-FE68-4933-B189-746D2DA3E062\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"9D5DE9D1-C334-452C-A64B-D74A48017B6D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_for_wago_touch_panels_600:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"966AEA54-4939-4C84-8D8B-7C70D361555B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.20\",\"matchCriteriaId\":\"A33E4442-F316-439F-83BD-047A34EF6E14\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_rte_sl_\\\\(for_beckhoff_cx\\\\):*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.20\",\"matchCriteriaId\":\"8AC245C1-F19D-417A-801E-D08B0ED81651\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.20\",\"matchCriteriaId\":\"F1A0B9C6-534C-4D2C-BC62-620786CE748F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.20\",\"matchCriteriaId\":\"22F16730-93D3-41D4-B5D0-F507BC2D5A03\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.20\",\"matchCriteriaId\":\"05792C1C-C4BB-4084-96A3-69544076F944\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:edge_gateway:*:*:*:*:*:windows:*:*\",\"versionEndExcluding\":\"3.5.18.20\",\"matchCriteriaId\":\"6C919501-6AFE-4D4C-84EF-C6AF30EBB769\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:edge_gateway:*:*:*:*:*:linux:*:*\",\"versionEndExcluding\":\"4.5.0.0\",\"matchCriteriaId\":\"E36291AE-21CB-4ECB-8816-D50712C70E30\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.20\",\"matchCriteriaId\":\"26B19D43-1A55-45E5-9C0A-00E9487B4282\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:gateway:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.20\",\"matchCriteriaId\":\"73C1F863-AAC0-446A-98E1-436916DA66B9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.20\",\"matchCriteriaId\":\"C26E9A35-AEB3-4856-8410-989D422A6D95\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.5.18.20\",\"matchCriteriaId\":\"26CA4951-7DD0-4477-8C36-EC07191CAC8F\"}]}]}],\"references\":[{\"url\":\"https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.