A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < CPC80 V16.30), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < CPC80 V16.30), CP-8021 MASTER MODULE (All versions < CPC80 V16.30), CP-8022 MASTER MODULE WITH GPRS (All versions < CPC80 V16.30). When using the HTTPS server under specific conditions, affected devices do not properly free resources. This could allow an unauthenticated remote attacker to put the device into a denial of service condition.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:43.055Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491621.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c CPC80 V16.30"
            }
          ]
        },
        {
          "product": "CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c CPC80 V16.30"
            }
          ]
        },
        {
          "product": "CP-8021 MASTER MODULE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c CPC80 V16.30"
            }
          ]
        },
        {
          "product": "CP-8022 MASTER MODULE WITH GPRS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c CPC80 V16.30"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C (All versions \u003c CPC80 V16.30), CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C (All versions \u003c CPC80 V16.30), CP-8021 MASTER MODULE (All versions \u003c CPC80 V16.30), CP-8022 MASTER MODULE WITH GPRS (All versions \u003c CPC80 V16.30). When using the HTTPS server under specific conditions, affected devices do not properly free resources. This could allow an unauthenticated remote attacker to put the device into a denial of service condition."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-772",
              "description": "CWE-772: Missing Release of Resource after Effective Lifetime",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-12T10:06:40",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491621.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-29884",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c CPC80 V16.30"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c CPC80 V16.30"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CP-8021 MASTER MODULE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c CPC80 V16.30"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CP-8022 MASTER MODULE WITH GPRS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c CPC80 V16.30"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C (All versions \u003c CPC80 V16.30), CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C (All versions \u003c CPC80 V16.30), CP-8021 MASTER MODULE (All versions \u003c CPC80 V16.30), CP-8022 MASTER MODULE WITH GPRS (All versions \u003c CPC80 V16.30). When using the HTTPS server under specific conditions, affected devices do not properly free resources. This could allow an unauthenticated remote attacker to put the device into a denial of service condition."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-772: Missing Release of Resource after Effective Lifetime"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-491621.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491621.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-29884",
    "datePublished": "2022-07-12T10:06:40",
    "dateReserved": "2022-04-28T00:00:00",
    "dateUpdated": "2024-08-03T06:33:43.055Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-29884\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-07-12T10:15:10.547\",\"lastModified\":\"2024-11-21T06:59:54.170\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C (All versions \u003c CPC80 V16.30), CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C (All versions \u003c CPC80 V16.30), CP-8021 MASTER MODULE (All versions \u003c CPC80 V16.30), CP-8022 MASTER MODULE WITH GPRS (All versions \u003c CPC80 V16.30). When using the HTTPS server under specific conditions, affected devices do not properly free resources. This could allow an unauthenticated remote attacker to put the device into a denial of service condition.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en el MASTER MODULE CP-8000 CON E/S -25/+70\u00b0C (Todas las versiones anteriores a CPC80 V16.30), MASTER MODULE CP-8000 CON E/S -40/+70\u00b0C (Todas las versiones anteriores a CPC80 V16.30), MASTER MODULE CP-8021 (Todas las versiones anteriores a CPC80 V16.30), MASTER MODULE CP-8022 CON GPRS (Todas las versiones anteriores a CPC80 V16.30). Cuando es usado el servidor HTTPS en condiciones espec\u00edficas, los dispositivos afectados no liberan apropiadamente los recursos. Esto podr\u00eda permitir a un atacante remoto no autenticado poner el dispositivo en una condici\u00f3n de denegaci\u00f3n de servicio\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:N/A:C\",\"baseScore\":7.1,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-772\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-772\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sicam_a8000_cp-8000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16.30\",\"matchCriteriaId\":\"6A3EDA09-C712-416E-BEE4-B49F867FEB56\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sicam_a8000_cp-8000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8DEF18ED-BF87-4CFA-A4BA-3387AC8964B3\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sicam_a8000_cp-8021_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16.30\",\"matchCriteriaId\":\"41F8797E-D4EC-4758-B526-35178F304DE1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sicam_a8000_cp-8021:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"65362A2F-DB6D-4D7F-87B5-10E18EE990F0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sicam_a8000_cp-8022_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16.30\",\"matchCriteriaId\":\"1182239D-D513-4C0F-8460-D4BDD6A2373A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sicam_a8000_cp-8022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"64D59FE8-03FD-4E5B-B7D2-47F31E98A187\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-491621.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-491621.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.