CVE-2026-53478 (GCVE-0-2026-53478)
Vulnerability from cvelistv5 – Published: 2026-07-03 14:03 – Updated: 2026-07-03 14:03
VLAI
Summary
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution.
Severity
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , ≤ 8.8.0.0 or later
(semver)
Affected: 0 , ≤ 8.6.1.20 or later (semver) Affected: 0 , ≤ 8.3.1.40 or later (semver) Affected: 0 , ≤ 7.13.1.80 or later (semver) |
Date Public
2026-07-02 06:30
Credits
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThanOrEqual": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThanOrEqual": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThanOrEqual": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank songxiaoyue for reporting this issue."
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-03T14:03:29.533Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-53478",
"datePublished": "2026-07-03T14:03:29.533Z",
"dateReserved": "2026-06-09T17:04:35.249Z",
"dateUpdated": "2026-07-03T14:03:29.533Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2026-53478\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2026-07-03T15:16:32.840\",\"lastModified\":\"2026-07-03T15:16:32.840\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command (\u0027OS command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution.\"}],\"affected\":[{\"source\":\"security_alert@emc.com\",\"affectedData\":[{\"vendor\":\"Dell\",\"product\":\"PowerProtect Data Domain\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThanOrEqual\":\"8.8.0.0 or later\",\"versionType\":\"semver\",\"status\":\"affected\"},{\"version\":\"0\",\"lessThanOrEqual\":\"8.6.1.20 or later\",\"versionType\":\"semver\",\"status\":\"affected\"},{\"version\":\"0\",\"lessThanOrEqual\":\"8.3.1.40 or later\",\"versionType\":\"semver\",\"status\":\"affected\"},{\"version\":\"0\",\"lessThanOrEqual\":\"7.13.1.80 or later\",\"versionType\":\"semver\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities\",\"source\":\"security_alert@emc.com\"}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…