CVE-2026-48192 (GCVE-0-2026-48192)
Vulnerability from cvelistv5 – Published: 2026-06-30 14:30 – Updated: 2026-06-30 15:05
VLAI
Summary
A vulnerability has been identified in Mendix Studio Pro 10.11 (All versions), Mendix Studio Pro 10.12 (All versions), Mendix Studio Pro 10.13 (All versions), Mendix Studio Pro 10.14 (All versions), Mendix Studio Pro 10.15 (All versions), Mendix Studio Pro 10.16 (All versions), Mendix Studio Pro 10.17 (All versions), Mendix Studio Pro 10.18 (All versions), Mendix Studio Pro 10.19 (All versions), Mendix Studio Pro 10.20 (All versions), Mendix Studio Pro 10.21 (All versions), Mendix Studio Pro 10.22 (All versions), Mendix Studio Pro 10.23 (All versions), Mendix Studio Pro 10.24 (All versions < V10.24.21), Mendix Studio Pro 11.0 (All versions), Mendix Studio Pro 11.1 (All versions), Mendix Studio Pro 11.10 (All versions), Mendix Studio Pro 11.11 (All versions), Mendix Studio Pro 11.2 (All versions), Mendix Studio Pro 11.3 (All versions), Mendix Studio Pro 11.4 (All versions), Mendix Studio Pro 11.5 (All versions), Mendix Studio Pro 11.6 (All versions < V11.6.7), Mendix Studio Pro 11.7 (All versions), Mendix Studio Pro 11.8 (All versions), Mendix Studio Pro 11.9 (All versions). Affected versions of Mendix Studio Pro do not properly validate or sanitize project files processed during the build pipeline.
This could allow an attacker who tricks a user into opening and running a specially crafted malicious project locally on their system to execute arbitrary code in the context of that user.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
1 reference
Impacted products
26 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Mendix Studio Pro 10.11 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 10.12 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 10.13 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 10.14 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 10.15 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 10.16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 10.17 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 10.18 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 10.19 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 10.20 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 10.21 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 10.22 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 10.23 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 10.24 |
Affected:
0 , < V10.24.21
(custom)
|
|
| Siemens | Mendix Studio Pro 11.0 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 11.1 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 11.10 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 11.11 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 11.2 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 11.3 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 11.4 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 11.5 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 11.6 |
Affected:
0 , < V11.6.7
(custom)
|
|
| Siemens | Mendix Studio Pro 11.7 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 11.8 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Mendix Studio Pro 11.9 |
Affected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-48192",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-30T15:05:23.824249Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-30T15:05:37.197Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 10.11",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 10.12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 10.13",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 10.14",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 10.15",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 10.16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 10.17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 10.18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 10.19",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 10.20",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 10.21",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 10.22",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 10.23",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 10.24",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.24.21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 11.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 11.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 11.10",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 11.11",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 11.2",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 11.3",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 11.4",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 11.5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 11.6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.6.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 11.7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 11.8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Mendix Studio Pro 11.9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Mendix Studio Pro 10.11 (All versions), Mendix Studio Pro 10.12 (All versions), Mendix Studio Pro 10.13 (All versions), Mendix Studio Pro 10.14 (All versions), Mendix Studio Pro 10.15 (All versions), Mendix Studio Pro 10.16 (All versions), Mendix Studio Pro 10.17 (All versions), Mendix Studio Pro 10.18 (All versions), Mendix Studio Pro 10.19 (All versions), Mendix Studio Pro 10.20 (All versions), Mendix Studio Pro 10.21 (All versions), Mendix Studio Pro 10.22 (All versions), Mendix Studio Pro 10.23 (All versions), Mendix Studio Pro 10.24 (All versions \u003c V10.24.21), Mendix Studio Pro 11.0 (All versions), Mendix Studio Pro 11.1 (All versions), Mendix Studio Pro 11.10 (All versions), Mendix Studio Pro 11.11 (All versions), Mendix Studio Pro 11.2 (All versions), Mendix Studio Pro 11.3 (All versions), Mendix Studio Pro 11.4 (All versions), Mendix Studio Pro 11.5 (All versions), Mendix Studio Pro 11.6 (All versions \u003c V11.6.7), Mendix Studio Pro 11.7 (All versions), Mendix Studio Pro 11.8 (All versions), Mendix Studio Pro 11.9 (All versions). Affected versions of Mendix Studio Pro do not properly validate or sanitize project files processed during the build pipeline.\r\nThis could allow an attacker who tricks a user into opening and running a specially crafted malicious project locally on their system to execute arbitrary code in the context of that user."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:R/S:C/C:N/I:H/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:A/VC:N/VI:H/VA:N/SC:N/SI:H/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-30T14:30:59.828Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-779310.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-48192",
"datePublished": "2026-06-30T14:30:59.828Z",
"dateReserved": "2026-05-21T08:13:02.100Z",
"dateUpdated": "2026-06-30T15:05:37.197Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2026-48192\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2026-06-30T15:16:56.990\",\"lastModified\":\"2026-06-30T16:16:53.507\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Mendix Studio Pro 10.11 (All versions), Mendix Studio Pro 10.12 (All versions), Mendix Studio Pro 10.13 (All versions), Mendix Studio Pro 10.14 (All versions), Mendix Studio Pro 10.15 (All versions), Mendix Studio Pro 10.16 (All versions), Mendix Studio Pro 10.17 (All versions), Mendix Studio Pro 10.18 (All versions), Mendix Studio Pro 10.19 (All versions), Mendix Studio Pro 10.20 (All versions), Mendix Studio Pro 10.21 (All versions), Mendix Studio Pro 10.22 (All versions), Mendix Studio Pro 10.23 (All versions), Mendix Studio Pro 10.24 (All versions \u003c V10.24.21), Mendix Studio Pro 11.0 (All versions), Mendix Studio Pro 11.1 (All versions), Mendix Studio Pro 11.10 (All versions), Mendix Studio Pro 11.11 (All versions), Mendix Studio Pro 11.2 (All versions), Mendix Studio Pro 11.3 (All versions), Mendix Studio Pro 11.4 (All versions), Mendix Studio Pro 11.5 (All versions), Mendix Studio Pro 11.6 (All versions \u003c V11.6.7), Mendix Studio Pro 11.7 (All versions), Mendix Studio Pro 11.8 (All versions), Mendix Studio Pro 11.9 (All versions). Affected versions of Mendix Studio Pro do not properly validate or sanitize project files processed during the build pipeline.\\r\\nThis could allow an attacker who tricks a user into opening and running a specially crafted malicious project locally on their system to execute arbitrary code in the context of that user.\"}],\"affected\":[{\"source\":\"productcert@siemens.com\",\"affectedData\":[{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 10.11\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 10.12\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 10.13\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 10.14\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 10.15\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 10.16\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 10.17\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 10.18\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 10.19\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 10.20\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 10.21\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 10.22\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 10.23\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 10.24\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V10.24.21\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 11.0\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 11.1\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 11.10\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 11.11\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 11.2\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 11.3\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 11.4\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 11.5\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 11.6\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V11.6.7\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 11.7\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 11.8\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"Mendix Studio Pro 11.9\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:A/VC:N/VI:H/VA:N/SC:N/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"ACTIVE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"HIGH\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:H/UI:R/S:C/C:N/I:H/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.0,\"impactScore\":4.0}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2026-06-30T15:05:23.824249Z\",\"id\":\"CVE-2026-48192\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-94\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-779310.html\",\"source\":\"productcert@siemens.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-48192\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-06-30T15:05:23.824249Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-06-30T15:05:33.355Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 5.4, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:H/UI:R/S:C/C:N/I:H/A:N\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 6.8, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:A/VC:N/VI:H/VA:N/SC:N/SI:H/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 10.11\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 10.12\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 10.13\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 10.14\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 10.15\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 10.16\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 10.17\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 10.18\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 10.19\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 10.20\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 10.21\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 10.22\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 10.23\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 10.24\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V10.24.21\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 11.0\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 11.1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 11.10\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 11.11\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 11.2\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 11.3\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 11.4\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 11.5\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 11.6\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V11.6.7\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 11.7\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 11.8\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Mendix Studio Pro 11.9\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-779310.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Mendix Studio Pro 10.11 (All versions), Mendix Studio Pro 10.12 (All versions), Mendix Studio Pro 10.13 (All versions), Mendix Studio Pro 10.14 (All versions), Mendix Studio Pro 10.15 (All versions), Mendix Studio Pro 10.16 (All versions), Mendix Studio Pro 10.17 (All versions), Mendix Studio Pro 10.18 (All versions), Mendix Studio Pro 10.19 (All versions), Mendix Studio Pro 10.20 (All versions), Mendix Studio Pro 10.21 (All versions), Mendix Studio Pro 10.22 (All versions), Mendix Studio Pro 10.23 (All versions), Mendix Studio Pro 10.24 (All versions \u003c V10.24.21), Mendix Studio Pro 11.0 (All versions), Mendix Studio Pro 11.1 (All versions), Mendix Studio Pro 11.10 (All versions), Mendix Studio Pro 11.11 (All versions), Mendix Studio Pro 11.2 (All versions), Mendix Studio Pro 11.3 (All versions), Mendix Studio Pro 11.4 (All versions), Mendix Studio Pro 11.5 (All versions), Mendix Studio Pro 11.6 (All versions \u003c V11.6.7), Mendix Studio Pro 11.7 (All versions), Mendix Studio Pro 11.8 (All versions), Mendix Studio Pro 11.9 (All versions). Affected versions of Mendix Studio Pro do not properly validate or sanitize project files processed during the build pipeline.\\r\\nThis could allow an attacker who tricks a user into opening and running a specially crafted malicious project locally on their system to execute arbitrary code in the context of that user.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-94\", \"description\": \"CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2026-06-30T14:30:59.828Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-48192\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-06-30T15:05:37.197Z\", \"dateReserved\": \"2026-05-21T08:13:02.100Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2026-06-30T14:30:59.828Z\", \"assignerShortName\": \"siemens\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…