CVE-2026-4558 (GCVE-0-2026-4558)
Vulnerability from cvelistv5 – Published: 2026-03-22 17:29 – Updated: 2026-03-23 16:06
VLAI?
Title
Linksys MR9600 SmartConnect.lua smartConnectConfigure os command injection
Summary
A flaw has been found in Linksys MR9600 2.0.6.206937. Affected is the function smartConnectConfigure of the file SmartConnect.lua. Executing a manipulation of the argument configApSsid/configApPassphrase/srpLogin/srpPassword can lead to os command injection. The attack may be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
Credits
wuuu (VulDB User)
VulDB
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-4558",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-23T16:06:42.703555Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-23T16:06:52.992Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:linksys:mr9600_firmware:*:*:*:*:*:*:*:*"
],
"product": "MR9600",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "2.0.6.206937"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wuuu (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Linksys MR9600 2.0.6.206937. Affected is the function smartConnectConfigure of the file SmartConnect.lua. Executing a manipulation of the argument configApSsid/configApPassphrase/srpLogin/srpPassword can lead to os command injection. The attack may be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-22T17:29:35.187Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-352385 | Linksys MR9600 SmartConnect.lua smartConnectConfigure os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.352385"
},
{
"name": "VDB-352385 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.352385"
},
{
"name": "Submit #775036 | Linksys MR9600 firmware 2.0.6.206937 OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.775036"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/utmost3/cve/issues/1"
},
{
"tags": [
"product"
],
"url": "https://www.linksys.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-21T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-21T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-21T21:52:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Linksys MR9600 SmartConnect.lua smartConnectConfigure os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-4558",
"datePublished": "2026-03-22T17:29:35.187Z",
"dateReserved": "2026-03-21T20:47:50.172Z",
"dateUpdated": "2026-03-23T16:06:52.992Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2026-4558\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2026-03-22T18:16:06.023\",\"lastModified\":\"2026-03-23T14:31:37.267\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A flaw has been found in Linksys MR9600 2.0.6.206937. Affected is the function smartConnectConfigure of the file SmartConnect.lua. Executing a manipulation of the argument configApSsid/configApPassphrase/srpLogin/srpPassword can lead to os command injection. The attack may be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"PROOF_OF_CONCEPT\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"},{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://github.com/utmost3/cve/issues/1\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?ctiid.352385\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?id.352385\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?submit.775036\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://www.linksys.com/\",\"source\":\"cna@vuldb.com\"}]}}",
"vulnrichment": {
"containers": "{\"cna\": {\"title\": \"Linksys MR9600 SmartConnect.lua smartConnectConfigure os command injection\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"wuuu (VulDB User)\"}, {\"lang\": \"en\", \"type\": \"coordinator\", \"value\": \"VulDB\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR\"}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:linksys:mr9600_firmware:*:*:*:*:*:*:*:*\"], \"vendor\": \"Linksys\", \"product\": \"MR9600\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.0.6.206937\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2026-03-21T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2026-03-21T01:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2026-03-21T21:52:56.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.352385\", \"name\": \"VDB-352385 | Linksys MR9600 SmartConnect.lua smartConnectConfigure os command injection\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.352385\", \"name\": \"VDB-352385 | CTI Indicators (IOB, IOC, TTP, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.775036\", \"name\": \"Submit #775036 | Linksys MR9600 firmware 2.0.6.206937 OS Command Injection\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/utmost3/cve/issues/1\", \"tags\": [\"exploit\", \"issue-tracking\"]}, {\"url\": \"https://www.linksys.com/\", \"tags\": [\"product\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A flaw has been found in Linksys MR9600 2.0.6.206937. Affected is the function smartConnectConfigure of the file SmartConnect.lua. Executing a manipulation of the argument configApSsid/configApPassphrase/srpLogin/srpPassword can lead to os command injection. The attack may be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"OS Command Injection\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"Command Injection\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2026-03-22T17:29:35.187Z\"}}, \"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-4558\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-03-23T16:06:42.703555Z\"}}}], \"providerMetadata\": {\"shortName\": \"CISA-ADP\", \"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"dateUpdated\": \"2026-03-23T16:06:48.664Z\"}}]}",
"cveMetadata": "{\"cveId\": \"CVE-2026-4558\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-03-22T17:29:35.187Z\", \"dateReserved\": \"2026-03-21T20:47:50.172Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2026-03-22T17:29:35.187Z\", \"assignerShortName\": \"VulDB\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…