CVE-2025-9997 (GCVE-0-2025-9997)
Vulnerability from cvelistv5 – Published: 2025-09-09 21:12 – Updated: 2025-09-10 19:34
VLAI
EPSS
Summary
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.
Severity
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Saitel DR RTU |
Affected:
all versions , ≤ 11.06.29
(version)
|
|
| Schneider Electric | Saitel DP RTU |
Affected:
all versions , ≤ 11.06.33
(version)
|
Date Public
2025-09-09 04:01
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9997",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-10T19:34:13.130524Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-10T19:34:21.734Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Saitel DR RTU",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "11.06.29",
"status": "affected",
"version": "all versions",
"versionType": "version"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Saitel DP RTU",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "11.06.33",
"status": "affected",
"version": "all versions",
"versionType": "version"
}
]
}
],
"datePublic": "2025-09-09T04:01:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session."
}
],
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T21:12:35.969Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-9997",
"datePublished": "2025-09-09T21:12:35.969Z",
"dateReserved": "2025-09-04T16:16:04.091Z",
"dateUpdated": "2025-09-10T19:34:21.734Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-9997",
"date": "2026-05-30",
"epss": "0.00088",
"percentile": "0.25138"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2025-9997\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2025-09-09T22:15:34.833\",\"lastModified\":\"2025-09-11T17:14:10.147\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"PRESENT\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"LOW\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-02.pdf\",\"source\":\"cybersecurity@se.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-9997\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-09-10T19:34:13.130524Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-09-10T19:34:17.690Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 5.8, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"PRESENT\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"LOW\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"LOW\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"Saitel DR RTU\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\", \"versionType\": \"version\", \"lessThanOrEqual\": \"11.06.29\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Saitel DP RTU\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\", \"versionType\": \"version\", \"lessThanOrEqual\": \"11.06.33\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2025-09-09T04:01:00.000Z\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-02.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2025-09-09T21:12:35.969Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-9997\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-09-10T19:34:21.734Z\", \"dateReserved\": \"2025-09-04T16:16:04.091Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2025-09-09T21:12:35.969Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
FKIE_CVE-2025-9997
Vulnerability from fkie_nvd - Published: 2025-09-09 22:15 - Updated: 2026-04-15 00:35
Severity
Summary
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.
References
Impacted products
| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session."
}
],
"id": "CVE-2025-9997",
"lastModified": "2026-04-15T00:35:42.020",
"metrics": {
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
},
"published": "2025-09-09T22:15:34.833",
"references": [
{
"source": "cybersecurity@se.com",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-02.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
GHSA-22Q2-GF4F-HVW6
Vulnerability from github – Published: 2025-09-10 00:31 – Updated: 2025-09-10 00:31
VLAI
Details
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.
Severity
{
"affected": [],
"aliases": [
"CVE-2025-9997"
],
"database_specific": {
"cwe_ids": [
"CWE-78"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2025-09-09T22:15:34Z",
"severity": "MODERATE"
},
"details": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.",
"id": "GHSA-22q2-gf4f-hvw6",
"modified": "2025-09-10T00:31:01Z",
"published": "2025-09-10T00:31:01Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-9997"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-02.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"type": "CVSS_V4"
}
]
}
ICSA-25-261-03
Vulnerability from csaf_cisa - Published: 2025-09-18 06:00 - Updated: 2025-09-18 06:00Summary
Schneider Electric Saitel DR & Saitel DP Remote Terminal Unit
Notes
Legal Notice: All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation: Successful exploitation of these vulnerabilities could enable an attacker to execute arbitrary shell commands on the affected devices.
Critical infrastructure sectors: Commercial Facilities, Critical Manufacturing, Energy
Countries/areas deployed: Worldwide
Company headquarters location: France
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Recommended Practices: Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices: No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.
6.6 (Medium)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Schneider Electric Saitel DR RTU: <=11.06.29
Schneider Electric / Schneider Electric Saitel DR RTU
|
<=11.06.29 |
Mitigation
Vendor Fix
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
fix
|
|
|
Schneider Electric Schneider Electric Saitel DP RTU: <=11.06.33
Schneider Electric / Schneider Electric Saitel DP RTU
|
<=11.06.33 |
Mitigation
Vendor Fix
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
fix
|
6.6 (Medium)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Schneider Electric Saitel DR RTU: <=11.06.29
Schneider Electric / Schneider Electric Saitel DR RTU
|
<=11.06.29 |
Mitigation
Vendor Fix
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
fix
|
|
|
Schneider Electric Schneider Electric Saitel DP RTU: <=11.06.33
Schneider Electric / Schneider Electric Saitel DP RTU
|
<=11.06.33 |
Mitigation
Vendor Fix
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
fix
|
References
14 references
Acknowledgments
GAI NetConsult GmbH
Robin Senn
GAI NetConsult GmbH
Sebastian Krause
{
"document": {
"acknowledgments": [
{
"names": [
"Robin Senn"
],
"organization": "GAI NetConsult GmbH",
"summary": "reporting CVE-2025-9996 to Schneider Electric"
},
{
"names": [
"Sebastian Krause"
],
"organization": "GAI NetConsult GmbH",
"summary": "reporting CVE-2025-9997 to Schneider Electric"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could enable an attacker to execute arbitrary shell commands on the affected devices.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities, Critical Manufacturing, Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-25-261-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-261-03.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-25-261-03 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
}
],
"title": "Schneider Electric Saitel DR \u0026 Saitel DP Remote Terminal Unit",
"tracking": {
"current_release_date": "2025-09-18T06:00:00.000000Z",
"generator": {
"date": "2025-09-18T14:55:14.439913Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-261-03",
"initial_release_date": "2025-09-18T06:00:00.000000Z",
"revision_history": [
{
"date": "2025-09-18T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=11.06.29",
"product": {
"name": "Schneider Electric Schneider Electric Saitel DR RTU: \u003c=11.06.29",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Schneider Electric Saitel DR RTU"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=11.06.33",
"product": {
"name": "Schneider Electric Schneider Electric Saitel DP RTU: \u003c=11.06.33",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Schneider Electric Saitel DP RTU"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-9996",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A OS command injection vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in anSSH session.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-9996"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Schneider Electric Saitel DR RTU Versions 11.06.29 and prior: HUe Firmware version 11.06.30 of Saitel DR includes a fix for this vulnerability and is available for download. A reboot is necessary to complete the firmware upgrade.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=62685"
},
{
"category": "vendor_fix",
"details": "Schneider Electric Saitel DP RTU Versions 11.06.33 and prior: Firmware SM_CPU866e version 11.06.34 of Saitel DP includes a fix for this vulnerability and is available for download. A reboot is necessary to complete the firmware upgrade.",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=61747"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends that customers use appropriate patching methodologies when applying these patches to their systems. They strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center for assistance removing a patch.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "If customers are not able to apply these patches, Schneider Electric recommends immediately applying the following mitigations to reduce the risk of exploitation:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Restrict access to BLMon by assigning permissions only to a limited set of user roles.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Ensure users are assigned the least privileged role that still allows them to perform their designated tasks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Implement firewall rules to restrict SSH connections to the device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends the following industry cybersecurity best practices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Place all controllers in locked cabinets and never leave them in the \"Program\" mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Never connect programming software to any network other than the network intended for that device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "mitigation",
"details": "For more information see the associated Schneider Electric CPCERT security advisory SEVD-2025-252-02 Saitel DR \u0026 Saitel DP Remote Terminal Unit - SEVD-2025-252-02 PDF Version, Saitel DR \u0026 Saitel DP Remote Terminal Unit - SEVD-2025-252-02 CSAF Version.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-02.pdf"
},
{
"category": "mitigation",
"details": "For more information see the associated Schneider Electric CPCERT security advisory SEVD-2025-252-02 Saitel DR \u0026 Saitel DP Remote Terminal Unit - SEVD-2025-252-02 PDF Version, Saitel DR \u0026 Saitel DP Remote Terminal Unit - SEVD-2025-252-02 CSAF Version.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-252-02.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2025-9997",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "CWE-78: Improper Neutralization of Special Elements used in an OS Command vulnerability exists that couldcause command injection in BLMon that is executed in the operating system console when in a SSH session.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-9997"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Schneider Electric Saitel DR RTU Versions 11.06.29 and prior: HUe Firmware version 11.06.30 of Saitel DR includes a fix for this vulnerability and is available for download. A reboot is necessary to complete the firmware upgrade.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=62685"
},
{
"category": "vendor_fix",
"details": "Schneider Electric Saitel DP RTU Versions 11.06.33 and prior: Firmware SM_CPU866e version 11.06.34 of Saitel DP includes a fix for this vulnerability and is available for download. A reboot is necessary to complete the firmware upgrade.",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=61747"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends that customers use appropriate patching methodologies when applying these patches to their systems. They strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center for assistance removing a patch.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "If customers are not able to apply these patches, Schneider Electric recommends immediately applying the following mitigations to reduce the risk of exploitation:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Restrict access to BLMon by assigning permissions only to a limited set of user roles.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Ensure users are assigned the least privileged role that still allows them to perform their designated tasks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Implement firewall rules to restrict SSH connections to the device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends the following industry cybersecurity best practices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Place all controllers in locked cabinets and never leave them in the \"Program\" mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Never connect programming software to any network other than the network intended for that device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "mitigation",
"details": "For more information see the associated Schneider Electric CPCERT security advisory SEVD-2025-252-02 Saitel DR \u0026 Saitel DP Remote Terminal Unit - SEVD-2025-252-02 PDF Version, Saitel DR \u0026 Saitel DP Remote Terminal Unit - SEVD-2025-252-02 CSAF Version.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-02.pdf"
},
{
"category": "mitigation",
"details": "For more information see the associated Schneider Electric CPCERT security advisory SEVD-2025-252-02 Saitel DR \u0026 Saitel DP Remote Terminal Unit - SEVD-2025-252-02 PDF Version, Saitel DR \u0026 Saitel DP Remote Terminal Unit - SEVD-2025-252-02 CSAF Version.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-252-02.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
NCSC-2025-0276
Vulnerability from csaf_ncscnl - Published: 2025-09-09 15:16 - Updated: 2025-09-09 15:16Summary
Kwetsbaarheden verholpen in Schneider Electric Saitel
Notes
The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:
NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.
NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.
This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings.
Feiten: Schneider Electric heeft kwetsbaarheden verholpen in Saitel componenten.
Interpretaties: De kwetsbaarheden bevinden zich in de wijze waarop de BLMon Console omgaat met speciale elementen in besturingssysteemcommando's tijdens SSH-sessies. Een kwaadwillende kan deze kwetsbaarheden misbruiken om ongeautoriseerde shell-commando's uit te voeren, wat kan leiden tot een compromittering van de systeemintegriteit.
Voor succesvol misbruik moet de kwaadwillende toegang hebben tot de productie-omgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.
Oplossingen: Schneider Electric heeft updates uitgebracht om de kwetsbaarheden te verhelpen. Zie bijgevoegde referenties voor meer informatie.
Kans: medium
Schade: high
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
6.6 (Medium)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Schneider Electric / Saitel DP RTU
|
vers:unknown/* | ||
|
vers:unknown/*
Schneider Electric / Saitel DR RTU
|
vers:unknown/* |
6.6 (Medium)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
vers:unknown/*
Schneider Electric / Saitel DP RTU
|
vers:unknown/* | ||
|
vers:unknown/*
Schneider Electric / Saitel DR RTU
|
vers:unknown/* |
References
3 references
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE"
}
},
"lang": "nl",
"notes": [
{
"category": "legal_disclaimer",
"text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings."
},
{
"category": "description",
"text": "Schneider Electric heeft kwetsbaarheden verholpen in Saitel componenten.",
"title": "Feiten"
},
{
"category": "description",
"text": "De kwetsbaarheden bevinden zich in de wijze waarop de BLMon Console omgaat met speciale elementen in besturingssysteemcommando\u0027s tijdens SSH-sessies. Een kwaadwillende kan deze kwetsbaarheden misbruiken om ongeautoriseerde shell-commando\u0027s uit te voeren, wat kan leiden tot een compromittering van de systeemintegriteit.\n\nVoor succesvol misbruik moet de kwaadwillende toegang hebben tot de productie-omgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.",
"title": "Interpretaties"
},
{
"category": "description",
"text": "Schneider Electric heeft updates uitgebracht om de kwetsbaarheden te verhelpen. Zie bijgevoegde referenties voor meer informatie.",
"title": "Oplossingen"
},
{
"category": "general",
"text": "medium",
"title": "Kans"
},
{
"category": "general",
"text": "high",
"title": "Schade"
},
{
"category": "general",
"text": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"title": "CWE-78"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "cert@ncsc.nl",
"name": "Nationaal Cyber Security Centrum",
"namespace": "https://www.ncsc.nl/"
},
"references": [
{
"category": "external",
"summary": "Reference",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-02.pdf"
}
],
"title": "Kwetsbaarheden verholpen in Schneider Electric Saitel",
"tracking": {
"current_release_date": "2025-09-09T15:16:00.122647Z",
"generator": {
"date": "2025-08-04T16:30:00Z",
"engine": {
"name": "V.A.",
"version": "1.3"
}
},
"id": "NCSC-2025-0276",
"initial_release_date": "2025-09-09T15:16:00.122647Z",
"revision_history": [
{
"date": "2025-09-09T15:16:00.122647Z",
"number": "1.0.0",
"summary": "Initiele versie"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-1"
}
}
],
"category": "product_name",
"name": "Saitel DP RTU"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:unknown/*",
"product": {
"name": "vers:unknown/*",
"product_id": "CSAFPID-2"
}
}
],
"category": "product_name",
"name": "Saitel DR RTU"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-9996",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "other",
"text": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"title": "CWE-78"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-9996 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-9996.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2"
]
}
],
"title": "CVE-2025-9996"
},
{
"cve": "CVE-2025-9997",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "other",
"text": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"title": "CWE-78"
}
],
"product_status": {
"known_affected": [
"CSAFPID-1",
"CSAFPID-2"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-9997 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-9997.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-1",
"CSAFPID-2"
]
}
],
"title": "CVE-2025-9997"
}
]
}
SEVD-2025-252-02
Vulnerability from csaf_se - Published: 2025-09-09 04:00 - Updated: 2025-09-09 04:00Summary
Saitel DR & Saitel DP Remote Terminal Unit
Notes
General Security Recommendations: We strongly recommend the following industry cybersecurity best practices.
https://www.se.com/us/en/download/document/7EN52-0390/
* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.
* Place all controllers in locked cabinets and never leave them in the “Program” mode.
* Never connect programming software to any network other than the network intended for that device.
* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.
* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.
* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.
For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices https://www.se.com/us/en/download/document/7EN52-0390/ document.
For More Information: This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.
For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp
LEGAL DISCLAIMER: THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION
About Schneider Electric: Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and
sustainability for all. We call this Life Is On.
Our mission is to be the trusted partner in Sustainability and Efficiency.
We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart
industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep
domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,
software and services, delivering digital twins to enable profitable growth for our customers.
We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries
to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our
meaningful purpose of a sustainable future for all.
www.se.com
Overview: Schneider Electric is aware of vulnerabilities in its Saitel DR & Saitel DP RTU (Remote Terminal Unit)
product(s).
The Saitel DR RTU https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=62685#overview is a field device, offering a solid and powerful platform for data acquisition, communication,
automation and IED integration for distribution and transmission networks, generation sector and railway.
The Saitel DP RTU https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=61747 is a modular platform for medium voltage and low voltage public distribution and
transmission network management.
Failure to apply the remediations provided below may risk command injection attack, which could result in
arbitrary code execution.
The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 (CVSS v4.0 https://www.first.org/cvss/calculator/4.0). CVSS v3.1
will be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without
incorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score
the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as
the presence of mitigations in that environment. Environmental metrics may refine the relative severity posed
by the vulnerabilities described in this document within a customer’s environment.
Customers should use appropriate patching methodologies when applying these patches to their systems. We
strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and
Development environment or on an offline infrastructure. Contact Schneider Electric's Customer Care Center https://www.se.com/us/en/work/support/contacts.jsp if you need assistance removing a patch.
CWE-78: Improper Neutralization of Special Elements used in an OS Command vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session.
6.6 (Medium)
Affected products
Fixed
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Saitel DR RTU Version 11.06.30
Schneider Electric / Saitel DR RTU
|
11.06.30 | ||
|
Schneider Electric Saitel DP RTU Version 11.06.34
Schneider Electric / Saitel DP RTU
|
11.06.34 |
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Saitel DR RTU Versions 11.06.29 and prior
Schneider Electric / Saitel DR RTU
|
<=11.06.29 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric Saitel DP RTU Versions 11.06.33 and prior
Schneider Electric / Saitel DP RTU
|
<=11.06.33 |
Vendor Fix
fix
Mitigation
|
CWE-78: Improper Neutralization of Special Elements used in an OS Command vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.
6.6 (Medium)
Affected products
Fixed
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Saitel DR RTU Version 11.06.30
Schneider Electric / Saitel DR RTU
|
11.06.30 | ||
|
Schneider Electric Saitel DP RTU Version 11.06.34
Schneider Electric / Saitel DP RTU
|
11.06.34 |
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Saitel DR RTU Versions 11.06.29 and prior
Schneider Electric / Saitel DR RTU
|
<=11.06.29 |
Vendor Fix
fix
Mitigation
|
|
|
Schneider Electric Saitel DP RTU Versions 11.06.33 and prior
Schneider Electric / Saitel DP RTU
|
<=11.06.33 |
Vendor Fix
fix
Mitigation
|
References
3 references
Acknowledgments
GAI NetConsult GmbH
Robin Senn
Sebastian Krause
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\n\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices https://www.se.com/us/en/download/document/7EN52-0390/ document.",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\n\nFor further information related to cybersecurity in Schneider Electric\u0027s products, visit the company\u0027s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "Schneider\u0027s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and\r\nsustainability for all. We call this Life Is On.\n\nOur mission is to be the trusted partner in Sustainability and Efficiency.\n\nWe are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart\r\nindustries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep\r\ndomain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,\r\nsoftware and services, delivering digital twins to enable profitable growth for our customers.\n\nWe are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries\r\nto ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our\r\nmeaningful purpose of a sustainable future for all. \n\n www.se.com",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of vulnerabilities in its Saitel DR \u0026 Saitel DP RTU (Remote Terminal Unit)\r\nproduct(s). \n\nThe Saitel DR RTU https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=62685#overview is a field device, offering a solid and powerful platform for data acquisition, communication, \r\nautomation and IED integration for distribution and transmission networks, generation sector and railway.\n\nThe Saitel DP RTU https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=61747 is a modular platform for medium voltage and low voltage public distribution and \r\ntransmission network management.\n\nFailure to apply the remediations provided below may risk command injection attack, which could result in \r\narbitrary code execution. ",
"title": "Overview"
},
{
"category": "other",
"text": "The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 (CVSS v4.0 https://www.first.org/cvss/calculator/4.0). CVSS v3.1 \nwill be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without \nincorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score \nthe CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as \nthe presence of mitigations in that environment. Environmental metrics may refine the relative severity posed \nby the vulnerabilities described in this document within a customer\u2019s environment."
},
{
"category": "other",
"text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We \nstrongly recommend the use of back-ups and evaluating the impact of these patches in a Test and \nDevelopment environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center https://www.se.com/us/en/work/support/contacts.jsp if you need assistance removing a patch. "
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Saitel DR \u0026 Saitel DP Remote Terminal Unit - SEVD-2025-252-02 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-02.pdf"
},
{
"category": "self",
"summary": "Saitel DR \u0026 Saitel DP Remote Terminal Unit - SEVD-2025-252-02 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-252-02.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "Saitel DR \u0026 Saitel DP Remote Terminal Unit",
"tracking": {
"current_release_date": "2025-09-09T04:00:00.000Z",
"generator": {
"date": "2025-09-05T09:57:52.871Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2025-252-02",
"initial_release_date": "2025-09-09T04:00:00.000Z",
"revision_history": [
{
"date": "2025-09-09T04:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=11.06.29",
"product": {
"name": "Schneider Electric Saitel DR RTU Versions 11.06.29 and prior",
"product_id": "1"
}
},
{
"category": "product_version",
"name": "11.06.30",
"product": {
"name": "Schneider Electric Saitel DR RTU Version 11.06.30",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Saitel DR RTU"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=11.06.33",
"product": {
"name": "Schneider Electric Saitel DP RTU Versions 11.06.33 and prior",
"product_id": "3"
}
},
{
"category": "product_version",
"name": "11.06.34",
"product": {
"name": "Schneider Electric Saitel DP RTU Version 11.06.34",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Saitel DP RTU"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Robin Senn",
"Sebastian Krause"
],
"organization": "GAI NetConsult GmbH"
}
],
"cve": "CVE-2025-9996",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "description",
"text": "CWE-78: Improper Neutralization of Special Elements used in an OS Command vulnerability exists that could \r\ncause the execution of any shell command when executing a netstat command using BLMon Console in an \r\nSSH session.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2",
"4"
],
"known_affected": [
"1",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "HUe Firmware version 11.06.30 of Saitel DR includes a fix for this \r\nvulnerability and is available for download here:\r\n\u2022 https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=62685\r\n\r\nA reboot is needed to complete the firmware upgrade.",
"product_ids": [
"1"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=62685"
},
{
"category": "vendor_fix",
"details": "Firmware SM_CPU866e version 11.06.34 of Saitel DP includes a fix for this \r\nvulnerability and is available for download here:\r\n\u2022 https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=61747\r\n\r\nA reboot is needed to complete the firmware upgrade.",
"product_ids": [
"3"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=61747"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit: \r\n\n* Restrict access to BLMon by assigning permissions only to a limited set of user roles. \n\n* Ensure users are assigned the least privileged role that still allows them to perform their designated \r\ntasks.\r\n\n* Implement firewall rules to restrict SSH connections to the device.",
"product_ids": [
"1",
"3"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"products": [
"1",
"3"
]
}
],
"title": "CVE-2025-9996"
},
{
"acknowledgments": [
{
"names": [
"Robin Senn",
"Sebastian Krause"
],
"organization": "GAI NetConsult GmbH"
}
],
"cve": "CVE-2025-9997",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "description",
"text": "CWE-78: Improper Neutralization of Special Elements used in an OS Command vulnerability exists that could \r\ncause command injection in BLMon that is executed in the operating system console when in a SSH session.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2",
"4"
],
"known_affected": [
"1",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "HUe Firmware version 11.06.30 of Saitel DR includes a fix for this \r\nvulnerability and is available for download here:\r\n\u2022 https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=62685\r\n\r\nA reboot is needed to complete the firmware upgrade.",
"product_ids": [
"1"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=62685"
},
{
"category": "vendor_fix",
"details": "Firmware SM_CPU866e version 11.06.34 of Saitel DP includes a fix for this \r\nvulnerability and is available for download here:\r\n\u2022 https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=61747\r\n\r\nA reboot is needed to complete the firmware upgrade.",
"product_ids": [
"3"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=61747"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit: \r\n\n* Restrict access to BLMon by assigning permissions only to a limited set of user roles. \n\n* Ensure users are assigned the least privileged role that still allows them to perform their designated \r\ntasks.\r\n\n* Implement firewall rules to restrict SSH connections to the device.",
"product_ids": [
"1",
"3"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
},
"products": [
"1",
"3"
]
}
],
"title": "CVE-2025-9997"
}
]
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.