CVE-2024-53649
Vulnerability from cvelistv5
Published
2025-01-14 10:30
Modified
2025-02-11 10:28
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
7.1 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
7.1 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.90), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SA82 (CP150) (All versions < V9.80), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SD82 (CP150) (All versions < V9.80), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SK82 (CP150) (All versions < V9.80), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SL82 (CP150) (All versions < V9.80), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions < V9.80), SIPROTEC 5 7SX82 (CP150) (All versions < V9.80), SIPROTEC 5 7SX85 (CP300) (All versions < V9.80), SIPROTEC 5 7SY82 (CP150) (All versions < V9.80), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80), SIPROTEC 5 7UT82 (CP150) (All versions < V9.80), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (All versions < V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.80). Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices.
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-53649", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-14T14:31:48.612161Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-14T14:33:11.420Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD84 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MD89 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.90", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 6MU85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7KE85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SA87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SD87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ81 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ81 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SJ86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SK82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SK82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SK85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SL87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SS85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7ST85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7ST86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SX82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SX85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7SY82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UM85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT82 (CP100)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT82 (CP150)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT86 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7UT87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7VE85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7VK87 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "V7.80", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 7VU85 (CP300)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPROTEC 5 Compact 7SX800 (CP050)", "vendor": "Siemens", "versions": [ { "lessThan": "V9.80", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V9.80), SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V7.80 \u003c V9.90), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SA82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SD82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SK82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SL82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V9.80), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V9.80), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7UT82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V9.80). Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-552", "description": "CWE-552: Files or Directories Accessible to External Parties", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-11T10:28:53.974Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-194557.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-53649", "datePublished": "2025-01-14T10:30:13.430Z", "dateReserved": "2024-11-21T13:26:39.693Z", "dateUpdated": "2025-02-11T10:28:53.974Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-53649\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2025-01-14T11:15:16.820\",\"lastModified\":\"2025-02-11T11:15:14.710\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V9.80), SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V7.80 \u003c V9.90), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SA82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SD82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SK82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SL82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V9.80), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V9.80), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7UT82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V9.80). Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIPROTEC 5 6MD84 (CP300) (Todas las versiones \u0026lt; V9.80), SIPROTEC 5 6MD85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 6MD86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 6MD89 (CP300) (Todas las versiones \u0026gt;= V7.80), SIPROTEC 5 6MU85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7KE85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7SA82 (CP100) (Todas las versiones \u0026gt;= V7.80), SIPROTEC 5 7SA82 (CP150) (Todas las versiones \u0026lt; V9.80), SIPROTEC 5 7SA86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7SA87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7SD82 (CP100) (Todas las versiones \u0026gt;= V7.80), SIPROTEC 5 7SD82 (CP150) (Todas las versiones \u0026lt; V9.80), SIPROTEC 5 7SD86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7SD87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7SJ81 (CP100) (Todas las versiones \u0026gt;= V7.80), SIPROTEC 5 7SJ81 (CP150) (Todas las versiones \u0026lt; V9.80), SIPROTEC 5 7SJ82 (CP100) (Todas las versiones \u0026gt;= V7.80), SIPROTEC 5 7SJ82 (CP150) (Todas las versiones \u0026lt; V9.80), SIPROTEC 5 7SJ85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7SJ86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7SK82 (CP100) (Todas las versiones \u0026gt;= V7.80), SIPROTEC 5 7SK82 (CP150) (Todas las versiones \u0026lt; V9.80), SIPROTEC 5 7SK85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7SL82 (CP100) (Todas las versiones \u0026gt;= V7.80), SIPROTEC 5 7SL82 (CP150) (Todas las versiones \u0026lt; V9.80), SIPROTEC 5 7SL86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7SL87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7SS85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7ST85 (CP300) (Todas las versiones), SIPROTEC 5 7ST86 (CP300) (Todas las versiones \u0026lt; V9.80), SIPROTEC 5 7SX82 (CP150) (Todas las versiones \u0026lt; V9.80), SIPROTEC 5 7SX85 (CP300) (Todas las versiones \u0026lt; V9.80), SIPROTEC 5 7SY82 (CP150) (Todas las versiones \u0026lt; V9.80), SIPROTEC 5 7UM85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7UT82 (CP100) (Todas las versiones \u0026gt;= V7.80), SIPROTEC 5 7UT82 (CP150) (Todas las versiones \u0026lt; V9.80), SIPROTEC 5 7UT85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7UT86 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7UT87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7VE85 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7VK87 (CP300) (Todas las versiones \u0026gt;= V7.80 \u0026lt; V9.80), SIPROTEC 5 7VU85 (CP300) (todas las versiones anteriores a V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (todas las versiones anteriores a V9.80). Los dispositivos afectados no limitan adecuadamente la ruta a la que se puede acceder a trav\u00e9s de su servidor web. Esto podr\u00eda permitir que un atacante remoto autenticado lea archivos arbitrarios del sistema de archivos de los dispositivos afectados.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"HIGH\",\"vulnerableSystemIntegrity\":\"NONE\",\"vulnerableSystemAvailability\":\"NONE\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-552\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-194557.html\",\"source\":\"productcert@siemens.com\"}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-53649\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-14T14:31:48.612161Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-14T14:33:06.641Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 7.1, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 6MD84 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 6MD85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 6MD86 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 6MD89 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.90\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 6MU85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7KE85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SA82 (CP100)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SA82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SA86 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SA87 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SD82 (CP100)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SD82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SD86 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SD87 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SJ81 (CP100)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SJ81 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SJ82 (CP100)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SJ82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SJ85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SJ86 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SK82 (CP100)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SK82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SK85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SL82 (CP100)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SL82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SL86 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SL87 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SS85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7ST85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7ST86 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SX82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SX85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7SY82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7UM85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7UT82 (CP100)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7UT82 (CP150)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7UT85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7UT86 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7UT87 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7VE85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7VK87 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V7.80\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 7VU85 (CP300)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIPROTEC 5 Compact 7SX800 (CP050)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V9.80\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-194557.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V9.80), SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V7.80 \u003c V9.90), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SA82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SD82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SK82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SL82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V9.80), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V9.80), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7UT82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V9.80). Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-552\", \"description\": \"CWE-552: Files or Directories Accessible to External Parties\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2025-02-11T10:28:53.974Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2024-53649\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-11T10:28:53.974Z\", \"dateReserved\": \"2024-11-21T13:26:39.693Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2025-01-14T10:30:13.430Z\", \"assignerShortName\": \"siemens\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.