CVE-2020-35783
Vulnerability from cvelistv5
Published
2020-12-29 23:41
Modified
2024-08-04 17:09
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, GS116Ev2 before 2.6.0.48, JGS524Ev2 before 2.6.0.48, and JGS524PE before 2.6.0.48. The NSDP protocol version allows unauthenticated remote attackers to obtain all the switch configuration parameters by sending the corresponding read requests.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:09:15.185Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062637/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0383" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, GS116Ev2 before 2.6.0.48, JGS524Ev2 before 2.6.0.48, and JGS524PE before 2.6.0.48. The NSDP protocol version allows unauthenticated remote attackers to obtain all the switch configuration parameters by sending the corresponding read requests." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-16T19:24:29", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062637/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0383" }, { "tags": [ "x_refsource_MISC" ], "url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35783", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, GS116Ev2 before 2.6.0.48, JGS524Ev2 before 2.6.0.48, and JGS524PE before 2.6.0.48. The NSDP protocol version allows unauthenticated remote attackers to obtain all the switch configuration parameters by sending the corresponding read requests." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062637/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0383", "refsource": "MISC", "url": "https://kb.netgear.com/000062637/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0383" }, { "name": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/", "refsource": "MISC", "url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35783", "datePublished": "2020-12-29T23:41:04", "dateReserved": "2020-12-29T00:00:00", "dateUpdated": "2024-08-04T17:09:15.185Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-35783\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-12-30T00:15:13.267\",\"lastModified\":\"2024-11-21T05:28:05.050\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, GS116Ev2 before 2.6.0.48, JGS524Ev2 before 2.6.0.48, and JGS524PE before 2.6.0.48. The NSDP protocol version allows unauthenticated remote attackers to obtain all the switch configuration parameters by sending the corresponding read requests.\"},{\"lang\":\"es\",\"value\":\"Determinados dispositivos NETGEAR est\u00e1n afectados por una falta de control de acceso en el nivel de funci\u00f3n. Esto afecta a JGS516PE versiones anteriores a 2.6.0.48, GS116Ev2 versiones anteriores a 2.6.0.48, JGS524Ev2 versiones anteriores a 2.6.0.48 y JGS524PE versiones anteriores a 2.6.0.48. La versi\u00f3n del protocolo NSDP permite a los atacantes remotos no autentificados obtener todos los par\u00e1metros de configuraci\u00f3n del switch enviando las correspondientes peticiones de lectura.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:jgs516pe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.0.48\",\"matchCriteriaId\":\"83FA56EB-35CD-4A58-8019-C4597AAC0104\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:jgs516pe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DCBC0DAB-226E-4C95-9818-7758D37EFD10\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:jgs524e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.0.48\",\"matchCriteriaId\":\"19D0AC3E-87B5-435A-B203-E9759A4A5396\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:jgs524e:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CFF899BD-AA1E-4C47-BCFD-5E32F75F538A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:jgs524pe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.0.48\",\"matchCriteriaId\":\"62D7F6C3-8104-4C7D-AE9D-8C96D40221A3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:jgs524pe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D4A32288-19B5-4A8F-B883-FCC326B7032D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:gs116e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.0.48\",\"matchCriteriaId\":\"9CCEFE31-BAA8-4791-BB66-27D341EAE6C7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:gs116e:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6DA5EF92-9B28-4C81-8A95-C5BCEC19591A\"}]}]}],\"references\":[{\"url\":\"https://kb.netgear.com/000062637/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0383\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Not Applicable\"]},{\"url\":\"https://kb.netgear.com/000062637/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0383\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Not Applicable\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.