gsd-2020-35783
Vulnerability from gsd
Modified
2023-12-13 01:22
Details
Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, GS116Ev2 before 2.6.0.48, JGS524Ev2 before 2.6.0.48, and JGS524PE before 2.6.0.48. The NSDP protocol version allows unauthenticated remote attackers to obtain all the switch configuration parameters by sending the corresponding read requests.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2020-35783", "description": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, GS116Ev2 before 2.6.0.48, JGS524Ev2 before 2.6.0.48, and JGS524PE before 2.6.0.48. The NSDP protocol version allows unauthenticated remote attackers to obtain all the switch configuration parameters by sending the corresponding read requests.", "id": "GSD-2020-35783" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2020-35783" ], "details": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, GS116Ev2 before 2.6.0.48, JGS524Ev2 before 2.6.0.48, and JGS524PE before 2.6.0.48. The NSDP protocol version allows unauthenticated remote attackers to obtain all the switch configuration parameters by sending the corresponding read requests.", "id": "GSD-2020-35783", "modified": "2023-12-13T01:22:01.005186Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35783", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, GS116Ev2 before 2.6.0.48, JGS524Ev2 before 2.6.0.48, and JGS524PE before 2.6.0.48. The NSDP protocol version allows unauthenticated remote attackers to obtain all the switch configuration parameters by sending the corresponding read requests." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062637/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0383", "refsource": "MISC", "url": "https://kb.netgear.com/000062637/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0383" }, { "name": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/", "refsource": "MISC", "url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:jgs516pe_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:jgs516pe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:jgs524e_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:jgs524e:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:jgs524pe_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:jgs524pe:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:gs116e_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:gs116e:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35783" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, GS116Ev2 before 2.6.0.48, JGS524Ev2 before 2.6.0.48, and JGS524PE before 2.6.0.48. The NSDP protocol version allows unauthenticated remote attackers to obtain all the switch configuration parameters by sending the corresponding read requests." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062637/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0383", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062637/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0383" }, { "name": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/", "refsource": "MISC", "tags": [ "Not Applicable" ], "url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6 } }, "lastModifiedDate": "2021-03-23T17:16Z", "publishedDate": "2020-12-30T00:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.