Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, GS116Ev2 before 2.6.0.48, JGS524Ev2 before 2.6.0.48, and JGS524PE before 2.6.0.48. The NSDP protocol version allows unauthenticated remote attackers to obtain all the switch configuration parameters by sending the corresponding read requests. plural NETGEAR device Contains an unspecified vulnerability.Information may be obtained
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202012-1137", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "jgs524e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.0.48" }, { "model": "jgs524pe", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.0.48" }, { "model": "gs116e", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.0.48" }, { "model": "jgs516pe", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.0.48" }, { "model": "jgs524pe", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "jgs524e", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "jgs516pe", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "gs116e", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015073" }, { "db": "NVD", "id": "CVE-2020-35783" } ] }, "cve": "CVE-2020-35783", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2020-35783", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-35783", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "None", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-015073", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-35783", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2020-35783", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2020-35783", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202012-1743", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015073" }, { "db": "CNNVD", "id": "CNNVD-202012-1743" }, { "db": "NVD", "id": "CVE-2020-35783" }, { "db": "NVD", "id": "CVE-2020-35783" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, GS116Ev2 before 2.6.0.48, JGS524Ev2 before 2.6.0.48, and JGS524PE before 2.6.0.48. The NSDP protocol version allows unauthenticated remote attackers to obtain all the switch configuration parameters by sending the corresponding read requests. plural NETGEAR device Contains an unspecified vulnerability.Information may be obtained", "sources": [ { "db": "NVD", "id": "CVE-2020-35783" }, { "db": "JVNDB", "id": "JVNDB-2020-015073" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-35783", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-015073", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202012-1743", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015073" }, { "db": "CNNVD", "id": "CNNVD-202012-1743" }, { "db": "NVD", "id": "CVE-2020-35783" } ] }, "id": "VAR-202012-1137", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.43738003000000003 }, "last_update_date": "2024-11-23T21:51:07.359000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Missing\u00a0Function\u00a0Level\u00a0Access\u00a0Control\u00a0on\u00a0Some\u00a0Smart\u00a0Managed\u00a0Plus\u00a0Switches,\u00a0PSV-2020-0383", "trust": 0.8, "url": "https://kb.netgear.com/000062637/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0383" }, { "title": "Multiple Netgear Product access control error vulnerability fixes", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=138266" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015073" }, { "db": "CNNVD", "id": "CNNVD-202012-1743" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015073" }, { "db": "NVD", "id": "CVE-2020-35783" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/" }, { "trust": 1.6, "url": "https://kb.netgear.com/000062637/security-advisory-for-missing-function-level-access-control-on-some-smart-managed-plus-switches-psv-2020-0383" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35783" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015073" }, { "db": "CNNVD", "id": "CNNVD-202012-1743" }, { "db": "NVD", "id": "CVE-2020-35783" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-015073" }, { "db": "CNNVD", "id": "CNNVD-202012-1743" }, { "db": "NVD", "id": "CVE-2020-35783" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-09T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-015073" }, { "date": "2020-12-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1743" }, { "date": "2020-12-30T00:15:13.267000", "db": "NVD", "id": "CVE-2020-35783" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-09T07:46:00", "db": "JVNDB", "id": "JVNDB-2020-015073" }, { "date": "2021-03-24T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1743" }, { "date": "2024-11-21T05:28:05.050000", "db": "NVD", "id": "CVE-2020-35783" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1743" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 device \u00a0 Vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015073" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "access control error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1743" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.