Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    235 vulnerabilities by abb

    CVE-2025-7064 (GCVE-0-2025-7064)

    Vulnerability from cvelistv5 – Published: 2026-06-11 09:07 – Updated: 2026-06-11 12:43
    VLAI
    Title
    Freelance Security Lock – Access to Windows OS
    Summary
    Authentication bypass by primary weakness vulnerability in ABB Freelance. This issue affects Freelance: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, 2019 SP1, 2019 SP1 FP1, 2024.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-305 - Authentication bypass by primary weakness
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB Freelance Affected: 0 , ≤ 2013 (custom)
    Affected: 2013 SP1 (custom)
    Affected: 2016 (custom)
    Affected: 2016 SP1 (custom)
    Affected: 2019 (custom)
    Affected: 2019 SP1 (custom)
    Affected: 2019 SP1 FP1 (custom)
    Affected: 2024 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7064",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-11T12:43:43.075897Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-11T12:43:52.186Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Freelance",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2013",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2013 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2016 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019 SP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2019 SP1 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2024",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Authentication bypass by primary weakness vulnerability in ABB Freelance.\u003cp\u003eThis issue affects Freelance: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, 2019 SP1, 2019 SP1 FP1, 2024.\u003c/p\u003e"
                }
              ],
              "value": "Authentication bypass by primary weakness vulnerability in ABB Freelance.\n\nThis issue affects Freelance: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, 2019 SP1, 2019 SP1 FP1, 2024."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 6.6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NO",
                "Recovery": "USER",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 5.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "privilegesRequired": "LOW",
                "providerUrgency": "GREEN",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "DIFFUSE",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:L/SC:L/SI:H/SA:L/E:P/AU:N/R:U/V:D/RE:L/U:Green",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "LOW"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-305",
                  "description": "CWE-305 Authentication bypass by primary weakness",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-11T09:07:30.912Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA020361\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Freelance Security Lock \u2013 Access to Windows OS",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-7064",
        "datePublished": "2026-06-11T09:07:30.912Z",
        "dateReserved": "2025-07-04T09:09:57.969Z",
        "dateUpdated": "2026-06-11T12:43:52.186Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14774 (GCVE-0-2025-14774)

    Vulnerability from cvelistv5 – Published: 2026-06-03 09:48 – Updated: 2026-06-03 12:16
    VLAI
    Title
    Communication analysis between the Card Reader and TP2CardReaderService daemon
    Summary
    Incorrect Authorization vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB T-MAC Plus Affected: 4.0-24 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14774",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-03T12:14:15.995844Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-03T12:16:24.437Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "T-MAC Plus",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0-24",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Incorrect Authorization vulnerability in ABB T-MAC Plus.\u003cp\u003eThis issue affects T-MAC Plus: 4.0-24.\u003c/p\u003e"
                }
              ],
              "value": "Incorrect Authorization vulnerability in ABB T-MAC Plus.\n\nThis issue affects T-MAC Plus: 4.0-24."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "ADJACENT",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863 Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-03T09:48:00.681Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A7840\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Communication analysis between the Card Reader and TP2CardReaderService daemon",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-14774",
        "datePublished": "2026-06-03T09:48:00.681Z",
        "dateReserved": "2025-12-16T03:47:14.477Z",
        "dateUpdated": "2026-06-03T12:16:24.437Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14773 (GCVE-0-2025-14773)

    Vulnerability from cvelistv5 – Published: 2026-06-03 09:40 – Updated: 2026-06-03 12:24
    VLAI
    Title
    Stored Cross-Site Scripting in ABB T-MAC Plus web application
    Summary
    Improper neutralization of input during web page generation ('cross-site scripting') vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB T-MAC Plus Affected: 4.0-24 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14773",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-03T12:23:55.931603Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-03T12:24:07.651Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "T-MAC Plus",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0-24",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027) vulnerability in ABB T-MAC Plus.\u003cp\u003eThis issue affects T-MAC Plus: 4.0-24.\u003c/p\u003e"
                }
              ],
              "value": "Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027) vulnerability in ABB T-MAC Plus.\n\nThis issue affects T-MAC Plus: 4.0-24."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:A/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-03T09:40:00.432Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A7840\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Stored Cross-Site Scripting in ABB T-MAC Plus web application",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-14773",
        "datePublished": "2026-06-03T09:40:00.432Z",
        "dateReserved": "2025-12-16T03:47:13.941Z",
        "dateUpdated": "2026-06-03T12:24:07.651Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14772 (GCVE-0-2025-14772)

    Vulnerability from cvelistv5 – Published: 2026-06-03 09:25 – Updated: 2026-06-03 12:49
    VLAI
    Title
    Broken Access Control in ABB T-MAC Plus web application
    Summary
    Authorization bypass through User-Controlled key vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-639 - Authorization bypass through User-Controlled key
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB T-MAC Plus Affected: 4.0-24
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14772",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-03T12:47:39.611706Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-03T12:49:14.950Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "T-MAC Plus",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0-24"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Authorization bypass through User-Controlled key vulnerability in ABB T-MAC Plus.\u003cp\u003eThis issue affects T-MAC Plus: 4.0-24.\u003c/p\u003e"
                }
              ],
              "value": "Authorization bypass through User-Controlled key vulnerability in ABB T-MAC Plus.\n\nThis issue affects T-MAC Plus: 4.0-24."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization bypass through User-Controlled key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-03T09:25:56.511Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A7840\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Broken Access Control in ABB T-MAC Plus web application",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-14772",
        "datePublished": "2026-06-03T09:25:56.511Z",
        "dateReserved": "2025-12-16T03:47:13.359Z",
        "dateUpdated": "2026-06-03T12:49:14.950Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14771 (GCVE-0-2025-14771)

    Vulnerability from cvelistv5 – Published: 2026-06-03 09:16 – Updated: 2026-06-03 13:02
    VLAI
    Title
    File Disclosure in ABB T-MAC Plus web application and in ABB T-MAC plus Server - Default IIS Web Site
    Summary
    Files or directories accessible to external parties vulnerability in ABB T-MAC Plus. This issue affects T-MAC Plus: 4.0-24.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-552 - Files or directories accessible to external parties
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB T-MAC Plus Affected: 4.0-24 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14771",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-03T12:56:59.726942Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-03T13:02:53.833Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "T-MAC Plus",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0-24",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Files or directories accessible to external parties vulnerability in ABB T-MAC Plus.\u003cp\u003eThis issue affects T-MAC Plus: 4.0-24.\u003c/p\u003e"
                }
              ],
              "value": "Files or directories accessible to external parties vulnerability in ABB T-MAC Plus.\n\nThis issue affects T-MAC Plus: 4.0-24."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-552",
                  "description": "CWE-552 Files or directories accessible to external parties",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-03T09:16:02.527Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A7840\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "File Disclosure in ABB T-MAC Plus web application and in ABB T-MAC  plus Server - Default IIS Web Site",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-14771",
        "datePublished": "2026-06-03T09:16:02.527Z",
        "dateReserved": "2025-12-16T03:47:13.262Z",
        "dateUpdated": "2026-06-03T13:02:53.833Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-3756 (GCVE-0-2025-3756)

    Vulnerability from cvelistv5 – Published: 2026-04-13 17:11 – Updated: 2026-04-13 18:03
    VLAI
    Title
    Denial of Service Vulnerabilities in System 800xA, Symphony® Plus IEC 61850
    Summary
    A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.  The System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.     This issue affects AC800M (System 800xA): from 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-1284 - Improper validation of specified quantity in input
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB AC800M (System 800xA) Affected: 6.0.0x , ≤ 6.0.0303.0 (custom)
    Affected: 6.1.0x , ≤ 6.1.0031.0 (custom)
    Affected: 6.1.1x , ≤ 6.1.1004.0 (custom)
    Affected: 6.1.1x , ≤ 6.1.1202.0 (custom)
    Affected: 6.2.0x , ≤ 6.2.0006.0 (custom)
    Create a notification for this product.
    ABB Symphony Plus SD Series Affected: A_0 (custom)
    Affected: A_1 (custom)
    Affected: A_2.003 (custom)
    Affected: A_3.005 (custom)
    Affected: A_4.001 (custom)
    Affected: B_0.005 (custom)
    Create a notification for this product.
    ABB Symphony Plus MR (Melody Rack) Affected: 3.10 , ≤ 3.52 (custom)
    Create a notification for this product.
    ABB S+ Operations Affected: 2.1 (custom)
    Affected: 2.2 (custom)
    Affected: 2.3 (custom)
    Affected: 3.3 (custom)
    Create a notification for this product.
    Credits
    ABB thanks Hitachi Energy for sharing the information affecting a commonly used software component.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3756",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-13T18:02:41.810841Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-13T18:03:41.437Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "CI868"
              ],
              "product": "AC800M (System 800xA)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "6.0.0303.0",
                  "status": "affected",
                  "version": "6.0.0x",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.0031.0",
                  "status": "affected",
                  "version": "6.1.0x",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1004.0",
                  "status": "affected",
                  "version": "6.1.1x",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1202.0",
                  "status": "affected",
                  "version": "6.1.1x",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.2.0006.0",
                  "status": "affected",
                  "version": "6.2.0x",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "modules": [
                "CI850"
              ],
              "product": "Symphony Plus SD Series",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "A_0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "A_1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "A_2.003",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "A_3.005",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "A_4.001",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "B_0.005",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "modules": [
                "PM 877"
              ],
              "product": "Symphony Plus MR (Melody Rack)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "3.52",
                  "status": "affected",
                  "version": "3.10",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "S+ Operations",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.2",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.3",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "3.3",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB thanks Hitachi Energy for sharing the information affecting a commonly used software component."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003e\u003cdiv\u003eA vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.\u0026nbsp;\u003c/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eThe System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.\u003c/div\u003e\u003cdiv\u003e\u0026nbsp; \u0026nbsp;\u003c/div\u003e\u003c/div\u003e\u003cp\u003eThis issue affects AC800M (System 800xA):\u0026nbsp;\u003cspan\u003efrom 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3.\u003c/span\u003e\u003c/p\u003e"
                }
              ],
              "value": "A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.\u00a0\n\n\n\n\nThe System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.\n\n\u00a0 \u00a0\n\n\n\nThis issue affects AC800M (System 800xA):\u00a0from 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1284",
                  "description": "CWE-1284 Improper validation of specified quantity in input",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-13T17:11:08.412Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA020125\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Denial of Service Vulnerabilities in System  800xA, Symphony\u00ae Plus IEC 61850",
          "x_generator": {
            "engine": "Vulnogram 1.0.1"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-3756",
        "datePublished": "2026-04-13T17:11:08.412Z",
        "dateReserved": "2025-04-17T10:42:33.414Z",
        "dateUpdated": "2026-04-13T18:03:41.437Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-13779 (GCVE-0-2025-13779)

    Vulnerability from cvelistv5 – Published: 2026-03-13 13:11 – Updated: 2026-03-13 14:11
    VLAI
    Title
    Configuration Data Spill
    Summary
    Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing authentication for critical function
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB AWIN GW100 rev.2 Affected: 2.0-0 (custom)
    Affected: 2.0-1 (custom)
    Create a notification for this product.
    ABB AWIN GW120 Affected: 1.2-0 (custom)
    Affected: 1.2-1 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13779",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-13T14:11:49.624286Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-13T14:11:57.527Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW100 rev.2",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0-1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW120",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.2-1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.\u003cp\u003eThis issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.\u003c/p\u003e"
                }
              ],
              "value": "Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing authentication for critical function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T13:11:11.547Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Configuration Data Spill",
          "x_generator": {
            "engine": "Vulnogram 1.0.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-13779",
        "datePublished": "2026-03-13T13:11:11.547Z",
        "dateReserved": "2025-11-28T14:22:33.792Z",
        "dateUpdated": "2026-03-13T14:11:57.527Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-13778 (GCVE-0-2025-13778)

    Vulnerability from cvelistv5 – Published: 2026-03-13 13:08 – Updated: 2026-03-13 13:35
    VLAI
    Title
    Device Reboot Control
    Summary
    Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing authentication for critical function
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB AWIN GW100 rev.2 Affected: 2.0-0 (custom)
    Affected: 2.0-1 (custom)
    Create a notification for this product.
    ABB AWIN GW120 Affected: 1.2-0 (custom)
    Affected: 1.2-1 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13778",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-13T13:35:12.366891Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-13T13:35:18.364Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW100 rev.2",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0-1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW120",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.2-1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.\u003cp\u003eThis issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.\u003c/p\u003e"
                }
              ],
              "value": "Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing authentication for critical function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T13:12:03.419Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Device Reboot Control",
          "x_generator": {
            "engine": "Vulnogram 1.0.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-13778",
        "datePublished": "2026-03-13T13:08:40.380Z",
        "dateReserved": "2025-11-28T14:22:33.054Z",
        "dateUpdated": "2026-03-13T13:35:18.364Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-13777 (GCVE-0-2025-13777)

    Vulnerability from cvelistv5 – Published: 2026-03-13 13:05 – Updated: 2026-03-13 13:35
    VLAI
    Title
    Authentication Bypass due to Improper Session Validation
    Summary
    Authentication bypass by capture-replay vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-294 - Authentication bypass by capture-replay
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB AWIN GW100 rev.2 Affected: 2.0-0 (custom)
    Affected: 2.0-1 (custom)
    Create a notification for this product.
    ABB AWIN GW120 Affected: 1.2-0 (custom)
    Affected: 1.2-1 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13777",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-13T13:35:31.062507Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-13T13:35:36.115Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW100 rev.2",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0-1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AWIN GW120",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2-0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.2-1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Authentication bypass by capture-replay vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.\u003cp\u003eThis issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.\u003c/p\u003e"
                }
              ],
              "value": "Authentication bypass by capture-replay vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-294",
                  "description": "CWE-294 Authentication bypass by capture-replay",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-13T13:05:26.329Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Authentication Bypass due to Improper Session Validation",
          "x_generator": {
            "engine": "Vulnogram 1.0.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-13777",
        "datePublished": "2026-03-13T13:05:26.329Z",
        "dateReserved": "2025-11-28T14:22:32.497Z",
        "dateUpdated": "2026-03-13T13:35:36.115Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-14510 (GCVE-0-2025-14510)

    Vulnerability from cvelistv5 – Published: 2026-01-16 13:02 – Updated: 2026-01-16 14:08
    VLAI
    Title
    ABB Ability OPTIMAX Authentication Bypass in Single-Sign On
    Summary
    Incorrect Implementation of Authentication Algorithm vulnerability in ABB ABB Ability OPTIMAX.This issue affects ABB Ability OPTIMAX: 6.1, 6.2, from 6.3.0 before 6.3.1-251120, from 6.4.0 before 6.4.1-251120.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-303 - Incorrect Implementation of Authentication Algorithm
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB ABB Ability OPTIMAX Affected: 6.1 (custom)
    Affected: 6.2 (custom)
    Affected: 6.3.0 , < 6.3.1-251120 (custom)
    Affected: 6.4.0 , < 6.4.1-251120 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-14510",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-16T14:08:08.177702Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-16T14:08:21.597Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ABB Ability OPTIMAX",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "6.2",
                  "versionType": "custom"
                },
                {
                  "lessThan": "6.3.1-251120",
                  "status": "affected",
                  "version": "6.3.0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "6.4.1-251120",
                  "status": "affected",
                  "version": "6.4.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Incorrect Implementation of Authentication Algorithm vulnerability in ABB ABB Ability OPTIMAX.\u003cp\u003eThis issue affects ABB Ability OPTIMAX: 6.1, 6.2, from 6.3.0 before 6.3.1-251120, from 6.4.0 before 6.4.1-251120.\u003c/p\u003e"
                }
              ],
              "value": "Incorrect Implementation of Authentication Algorithm vulnerability in ABB ABB Ability OPTIMAX.This issue affects ABB Ability OPTIMAX: 6.1, 6.2, from 6.3.0 before 6.3.1-251120, from 6.4.0 before 6.4.1-251120."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-303",
                  "description": "CWE-303 Incorrect Implementation of Authentication Algorithm",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-16T13:02:30.774Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A1331\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "ABB Ability OPTIMAX Authentication Bypass in Single-Sign On",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-14510",
        "datePublished": "2026-01-16T13:02:30.774Z",
        "dateReserved": "2025-12-11T04:40:57.208Z",
        "dateUpdated": "2026-01-16T14:08:21.597Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-4677 (GCVE-0-2025-4677)

    Vulnerability from cvelistv5 – Published: 2026-01-07 17:09 – Updated: 2026-01-07 18:19
    VLAI
    Title
    Idle session timeout is not configured for multiple open ports
    Summary
    Insufficient Session Expiration vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-613 - Insufficient Session Expiration
    Assigner
    ABB
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-4677",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-07T18:17:02.695141Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-07T18:19:30.647Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WebPro SNMP Card PowerValue",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.1.8.k",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "WebPro SNMP Card PowerValue UL",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.1.8.k",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Insufficient Session Expiration vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.\u003cp\u003eThis issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K.\u003c/p\u003e"
                }
              ],
              "value": "Insufficient Session Expiration vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-613",
                  "description": "CWE-613 Insufficient Session Expiration",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-07T17:09:05.370Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2CRT000009\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Idle session timeout is not configured for multiple open ports",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-4677",
        "datePublished": "2026-01-07T17:09:05.370Z",
        "dateReserved": "2025-05-14T06:02:15.939Z",
        "dateUpdated": "2026-01-07T18:19:30.647Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-4676 (GCVE-0-2025-4676)

    Vulnerability from cvelistv5 – Published: 2026-01-07 17:02 – Updated: 2026-01-07 17:22
    VLAI
    Title
    Authentication bypass by brute forcing Authentication Headers
    Summary
    Incorrect Implementation of Authentication Algorithm vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-303 - Incorrect Implementation of Authentication Algorithm
    Assigner
    ABB
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-4676",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-07T17:22:25.611391Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-07T17:22:42.902Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WebPro SNMP Card PowerValue",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.1.8.k",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "WebPro SNMP Card PowerValue UL",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.1.8.k",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Incorrect Implementation of Authentication Algorithm vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.\u003cp\u003eThis issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K.\u003c/p\u003e"
                }
              ],
              "value": "Incorrect Implementation of Authentication Algorithm vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-303",
                  "description": "CWE-303 Incorrect Implementation of Authentication Algorithm",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-07T17:02:29.110Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2CRT000009\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Authentication bypass by brute forcing Authentication Headers",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-4676",
        "datePublished": "2026-01-07T17:02:29.110Z",
        "dateReserved": "2025-05-14T06:02:14.592Z",
        "dateUpdated": "2026-01-07T17:22:42.902Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-4675 (GCVE-0-2025-4675)

    Vulnerability from cvelistv5 – Published: 2026-01-07 16:55 – Updated: 2026-01-07 17:20
    VLAI
    Title
    Improper implementation of Modbus protocol leading to DOS attack
    Summary
    Improper Check for Unusual or Exceptional Conditions vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Assigner
    ABB
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-4675",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-07T17:19:49.307602Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-07T17:20:05.011Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "WebPro SNMP Card PowerValue",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.1.8.k",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "WebPro SNMP Card PowerValue UL",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.1.8.k",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Check for Unusual or Exceptional Conditions vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.\u003cp\u003eThis issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K.\u003c/p\u003e"
                }
              ],
              "value": "Improper Check for Unusual or Exceptional Conditions vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-07T16:55:43.036Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2CRT000009\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Improper implementation of Modbus protocol leading to DOS attack",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-4675",
        "datePublished": "2026-01-07T16:55:43.036Z",
        "dateReserved": "2025-05-14T06:02:12.696Z",
        "dateUpdated": "2026-01-07T17:20:05.011Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-12143 (GCVE-0-2025-12143)

    Vulnerability from cvelistv5 – Published: 2025-11-28 11:59 – Updated: 2025-11-28 14:16
    VLAI
    Title
    Stack Memory Corruption Vulnerability
    Summary
    Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB Terra AC wallbox Affected: 0 , ≤ 1.8.33 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-12143",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-28T14:16:36.401623Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-28T14:16:43.237Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Terra AC wallbox",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.8.33",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.\u003cp\u003eThis issue affects Terra AC wallbox: through 1.8.33.\u003c/p\u003e"
                }
              ],
              "value": "Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NO",
                "Recovery": "AUTOMATIC",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "DIFFUSE",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "LOW"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-28T11:59:27.485Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8107\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Stack Memory Corruption Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-12143",
        "datePublished": "2025-11-28T11:59:27.485Z",
        "dateReserved": "2025-10-24T10:40:24.131Z",
        "dateUpdated": "2025-11-28T14:16:43.237Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-10571 (GCVE-0-2025-10571)

    Vulnerability from cvelistv5 – Published: 2025-11-20 18:06 – Updated: 2025-11-21 16:05
    VLAI
    Title
    ABB Ability Edgenius Authentication Bypass
    Summary
    Authentication Bypass Using an Alternate Path or Channel vulnerability in ABB ABB Ability Edgenius.This issue affects ABB Ability Edgenius: 3.2.0.0, 3.2.1.1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-288 - Authentication Bypass Using an Alternate Path or Channel
    Assigner
    ABB
    References
    Impacted products
    Vendor Product Version
    ABB ABB Ability Edgenius Affected: 3.2.0.0
    Affected: 3.2.1.1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-10571",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-21T16:05:15.558943Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-21T16:05:22.625Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ABB Ability Edgenius",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.2.0.0"
                },
                {
                  "status": "affected",
                  "version": "3.2.1.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Authentication Bypass Using an Alternate Path or Channel vulnerability in ABB ABB Ability Edgenius.\u003cp\u003eThis issue affects ABB Ability Edgenius: 3.2.0.0, 3.2.1.1.\u003c/p\u003e"
                }
              ],
              "value": "Authentication Bypass Using an Alternate Path or Channel vulnerability in ABB ABB Ability Edgenius.This issue affects ABB Ability Edgenius: 3.2.0.0, 3.2.1.1."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-288",
                  "description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-20T18:06:00.586Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA022088\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "ABB has prepared an update to fix this vulnerability included in the latest Roll-Up, ABB Ability Edgenius \nversion 3.2.2.0. \nABB advises customers to upgrade as soon as possible. Until the upgrade is applied, ABB advises customers to disable the Edgenius Management Portal to mitigate the vulnerability.\n\n\u003cbr\u003e"
                }
              ],
              "value": "ABB has prepared an update to fix this vulnerability included in the latest Roll-Up, ABB Ability Edgenius \nversion 3.2.2.0. \nABB advises customers to upgrade as soon as possible. Until the upgrade is applied, ABB advises customers to disable the Edgenius Management Portal to mitigate the vulnerability."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "ABB Ability Edgenius Authentication Bypass",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove the exposure with well-known impact on functionality. ABB has tested the following workaround.\n\n \n\n\u003cbr\u003e"
                }
              ],
              "value": "Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove the exposure with well-known impact on functionality. ABB has tested the following workaround."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-10571",
        "datePublished": "2025-11-20T18:06:00.586Z",
        "dateReserved": "2025-09-16T16:33:45.185Z",
        "dateUpdated": "2025-11-21T16:05:22.625Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-12142 (GCVE-0-2025-12142)

    Vulnerability from cvelistv5 – Published: 2025-10-29 12:00 – Updated: 2025-10-29 13:30
    VLAI
    Title
    BSS(Block Started by Symbol) Memory Corruption Vulnerability
    Summary
    Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB Terra AC wallbox Affected: 0 , ≤ 1.8.33 (custom)
    Create a notification for this product.
    Date Public
    2025-10-27 04:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-12142",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-29T13:25:28.068483Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-29T13:30:33.090Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Terra AC wallbox",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.8.33",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:abb:terra_ac_wallbox:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "1.8.33",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "datePublic": "2025-10-27T04:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in ABB Terra AC wallbox.\u003cp\u003eThis issue affects Terra AC wallbox: through 1.8.33.\u003c/p\u003e"
                }
              ],
              "value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NO",
                "Recovery": "AUTOMATIC",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "DIFFUSE",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "LOW"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-29T12:00:42.236Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8107\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "BSS(Block Started by Symbol) Memory Corruption Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-12142",
        "datePublished": "2025-10-29T12:00:42.236Z",
        "dateReserved": "2025-10-24T10:40:22.394Z",
        "dateUpdated": "2025-10-29T13:30:33.090Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-5517 (GCVE-0-2025-5517)

    Vulnerability from cvelistv5 – Published: 2025-10-20 18:27 – Updated: 2025-10-20 18:47
    VLAI
    Title
    Heap Memory Corruption Vulnerability
    Summary
    Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): through 1.8.32; Terra AC wallbox (UL32A): through 1.8.2; Terra AC wallbox (MID/ CE) -Terra AC MID: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC Juno CE: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC PTB: through 1.8.21; Terra AC wallbox (JP): through 1.8.2.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    ABB
    Credits
    ABB also acknowledges and thanks Itai Shmueli from Saiflow who also responsibly disclosed these vulnerabilities and provided valuable input on product improvements.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-5517",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-20T18:47:11.327089Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-20T18:47:22.917Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Terra AC wallbox (UL40/80A)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.8.32",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Terra AC wallbox (UL32A)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.8.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Terra AC wallbox (MID/ CE) -Terra AC MID",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.8.32",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Terra AC wallbox (MID/ CE) -Terra AC Juno CE",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.8.32",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Terra AC wallbox (MID/ CE) -Terra AC PTB",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.8.21",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Terra AC wallbox (JP)",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.8.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB also acknowledges and thanks Itai Shmueli from Saiflow who also responsibly disclosed these vulnerabilities and provided valuable input on product improvements."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra AC wallbox (JP).\u003cp\u003eThis issue affects Terra AC wallbox (UL40/80A): through 1.8.32; Terra AC wallbox (UL32A): through 1.8.2; Terra AC wallbox (MID/ CE) -Terra AC MID: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC Juno CE: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC PTB: through 1.8.21; Terra AC wallbox (JP): through 1.8.2.\u003c/p\u003e"
                }
              ],
              "value": "Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): through 1.8.32; Terra AC wallbox (UL32A): through 1.8.2; Terra AC wallbox (MID/ CE) -Terra AC MID: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC Juno CE: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC PTB: through 1.8.21; Terra AC wallbox (JP): through 1.8.2."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-20T18:27:32.374Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8948\u0026LanguageCode=en\u0026DocumentPartId=PDF\u0026Action=Launch"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The problem is corrected in the following product versions; apply the following update depending on product variant:\u003cul\u003e\u003cli\u003eTerra AC wallbox (UL40/80A) 1.8.33\u003c/li\u003e\u003cli\u003eTerra AC wallbox (UL32A) 1.8.34\u003c/li\u003e\u003cli\u003eTerra AC MID 1.8.34\u003c/li\u003e\u003cli\u003eTerra AC Juno CE 1.8.34\u003c/li\u003e\u003cli\u003eTerra AC PTB 1.8.33\u003c/li\u003e\u003cli\u003eTerra AC wallbox (JP) 1.8.34\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "The problem is corrected in the following product versions; apply the following update depending on product variant:  *  Terra AC wallbox (UL40/80A) 1.8.33\n  *  Terra AC wallbox (UL32A) 1.8.34\n  *  Terra AC MID 1.8.34\n  *  Terra AC Juno CE 1.8.34\n  *  Terra AC PTB 1.8.33\n  *  Terra AC wallbox (JP) 1.8.34"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Heap Memory Corruption Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-5517",
        "datePublished": "2025-10-20T18:27:32.374Z",
        "dateReserved": "2025-06-03T08:51:33.612Z",
        "dateUpdated": "2025-10-20T18:47:22.917Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3465 (GCVE-0-2025-3465)

    Vulnerability from cvelistv5 – Published: 2025-10-20 17:52 – Updated: 2025-10-20 20:25
    VLAI
    Title
    Path Traversal Vulnerability
    Summary
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ABB CoreSense™ HM, ABB CoreSense™ M10.This issue affects CoreSense™ HM: through 2.3.1; CoreSense™ M10: through 1.4.1.12.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB CoreSense™ HM Affected: 0 , ≤ 2.3.1 (custom)
    Create a notification for this product.
    ABB CoreSense™ M10 Affected: 0 , ≤ 1.4.1.12 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3465",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-20T20:25:43.681537Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-20T20:25:53.371Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CoreSense\u2122 HM",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2.3.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CoreSense\u2122 M10",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.4.1.12",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ABB CoreSense\u2122 HM, ABB CoreSense\u2122 M10.\u003cp\u003eThis issue affects CoreSense\u2122 HM: through 2.3.1; CoreSense\u2122 M10: through 1.4.1.12.\u003c/p\u003e"
                }
              ],
              "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in ABB CoreSense\u2122 HM, ABB CoreSense\u2122 M10.This issue affects CoreSense\u2122 HM: through 2.3.1; CoreSense\u2122 M10: through 1.4.1.12."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-20T17:52:40.975Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=3KXG200000R4801\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The vulnerabilities are corrected in the following version: \n\n\u003cbr\u003e\n\nCoreSense\u2122 HM v2.3.4\n\n\u003cbr\u003e\n\nCoreSense\u2122 M10 v1.4.1.31\n\n\n\u003cbr\u003e"
                }
              ],
              "value": "The vulnerabilities are corrected in the following version: \n\n\n\n\nCoreSense\u2122 HM v2.3.4\n\n\n\n\nCoreSense\u2122 M10 v1.4.1.31"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Path Traversal Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-3465",
        "datePublished": "2025-10-20T17:52:40.975Z",
        "dateReserved": "2025-04-09T10:11:48.997Z",
        "dateUpdated": "2025-10-20T20:25:53.371Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-9574 (GCVE-0-2025-9574)

    Vulnerability from cvelistv5 – Published: 2025-10-20 16:56 – Updated: 2025-10-24 10:04
    VLAI
    Title
    Missing Authentication Vulnerability
    Summary
    Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .  All firmware versions with the Serial Number from 2000 to 5166
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    ABB
    Impacted products
    Date Public
    2025-10-20 00:36
    Credits
    ABB acknowledges Souvik Kandar of MicroSec (microsec.io), for reporting vulnerabilities in responsible disclosure.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-9574",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-20T17:31:19.456273Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-20T17:32:51.170Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ALS-mini-s4 IP",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ALS-mini-s8 IP",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB acknowledges Souvik Kandar of MicroSec (microsec.io), for reporting vulnerabilities in responsible disclosure."
            }
          ],
          "datePublic": "2025-10-20T00:36:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.\u003cp\u003eThis issue affects .\u0026nbsp;\n\nAll firmware versions with the Serial Number from 2000 to 5166\n\n\u003c/p\u003e"
                }
              ],
              "value": "Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .\u00a0\n\nAll firmware versions with the Serial Number from 2000 to 5166"
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "RED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "DIFFUSE",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:H/S:N/AU:Y/R:U/V:D/RE:M/U:Red",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "MODERATE"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-24T10:04:57.390Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=4TZ00000006007\u0026LanguageCode=en\u0026DocumentPartId=PDF\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Missing Authentication Vulnerability",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Workarounds are specific measures that a user can take to help block an attack. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can\nhelp block known attack vectors. When a workaround reduces functionality, this is identified below as\n\u201cImpact of workaround\u201d.\u003cbr\u003e\u003cbr\u003e\n\u2013 Physically disconnect the ethernet port if embedded web server is not being used.\u003cbr\u003e\u003cbr\u003e\nImpact of workaround\n\u003cbr\u003e\u003cbr\u003eThe embedded web server and all its functionalities, incl. load monitoring, alarms, remote configuration,\netc. will not be accessible. However, the product will continue functioning as normal based on configured control parameters.\n\n\u003cbr\u003e"
                }
              ],
              "value": "Workarounds are specific measures that a user can take to help block an attack. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can\nhelp block known attack vectors. When a workaround reduces functionality, this is identified below as\n\u201cImpact of workaround\u201d.\n\n\n\u2013 Physically disconnect the ethernet port if embedded web server is not being used.\n\n\nImpact of workaround\n\n\nThe embedded web server and all its functionalities, incl. load monitoring, alarms, remote configuration,\netc. will not be accessible. However, the product will continue functioning as normal based on configured control parameters."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-9574",
        "datePublished": "2025-10-20T16:56:32.337Z",
        "dateReserved": "2025-08-28T10:04:01.947Z",
        "dateUpdated": "2025-10-24T10:04:57.390Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-9970 (GCVE-0-2025-9970)

    Vulnerability from cvelistv5 – Published: 2025-10-08 16:32 – Updated: 2025-10-08 17:21
    VLAI
    Title
    Application credential stored in clear text in memory
    Summary
    Cleartext Storage of Sensitive Information in Memory vulnerability in ABB MConfig.This issue affects MConfig: through 1.4.9.21.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-316 - Cleartext Storage of Sensitive Information in Memory
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB MConfig Affected: 0 , ≤ 1.4.9.21 (custom)
    Create a notification for this product.
    Date Public
    2025-10-08 00:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-9970",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-08T17:21:21.311982Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-08T17:21:31.635Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "MConfig",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.4.9.21",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2025-10-08T00:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Cleartext Storage of Sensitive Information in Memory vulnerability in ABB MConfig.\u003cp\u003eThis issue affects MConfig: through 1.4.9.21.\u003c/p\u003e"
                }
              ],
              "value": "Cleartext Storage of Sensitive Information in Memory vulnerability in ABB MConfig.This issue affects MConfig: through 1.4.9.21."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 5.7,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:P/VC:L/VI:H/VA:H/SC:N/SI:N/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:L/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-316",
                  "description": "CWE-316 Cleartext Storage of Sensitive Information in Memory",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-08T16:32:55.889Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=4TZ00000006008\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Application credential stored in clear text in memory",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-9970",
        "datePublished": "2025-10-08T16:32:55.889Z",
        "dateReserved": "2025-09-04T06:56:17.904Z",
        "dateUpdated": "2025-10-08T17:21:31.635Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-22291 (GCVE-0-2021-22291)

    Vulnerability from cvelistv5 – Published: 2025-10-07 13:29 – Updated: 2025-10-07 13:52
    VLAI
    Title
    EIBPORT Reflected XSS
    Summary
    Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in ABB EIBPORT V3 KNX, ABB EIBPORT V3 KNX GSM.This issue affects EIBPORT V3 KNX: before 3.9.2; EIBPORT V3 KNX GSM: before 3.9.2.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB EIBPORT V3 KNX Affected: 0 , < 3.9.2 (custom)
    Create a notification for this product.
    ABB EIBPORT V3 KNX GSM Affected: 0 , < 3.9.2 (custom)
    Create a notification for this product.
    Date Public
    2025-10-07 00:30
    Credits
    ABB acknowledges and thanks Psytester for responsibly disclosing the vulnerabilities and helping to verify the resolving implementation.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-22291",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-10-07T13:51:59.700208Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-07T13:52:06.104Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EIBPORT V3  KNX",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "3.9.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EIBPORT V3  KNX GSM",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "3.9.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB acknowledges and thanks Psytester for responsibly disclosing the vulnerabilities and helping to verify the resolving implementation."
            }
          ],
          "datePublic": "2025-10-07T00:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in ABB EIBPORT V3 KNX, ABB EIBPORT V3 KNX GSM.\u003cp\u003eThis issue affects EIBPORT V3 KNX: before 3.9.2; EIBPORT V3 KNX GSM: before 3.9.2.\u003c/p\u003e"
                }
              ],
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in ABB EIBPORT V3 KNX, ABB EIBPORT V3 KNX GSM.This issue affects EIBPORT V3 KNX: before 3.9.2; EIBPORT V3 KNX GSM: before 3.9.2."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-07T13:29:06.908Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A7808\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "EIBPORT Reflected XSS",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2021-22291",
        "datePublished": "2025-10-07T13:29:06.908Z",
        "dateReserved": "2021-01-05T17:31:49.084Z",
        "dateUpdated": "2025-10-07T13:52:06.104Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-10504 (GCVE-0-2025-10504)

    Vulnerability from cvelistv5 – Published: 2025-09-29 04:12 – Updated: 2025-10-16 06:22
    VLAI
    Title
    Heap Memory Corruption Vulnerability
    Summary
    Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB Terra AC wallbox Affected: 0 , ≤ 1.8.33 (custom)
    Create a notification for this product.
    Date Public
    2025-09-28 04:00
    Credits
    ABB acknowledges and thanks Ryo Kato for responsibly disclosing the vulnerabilities and providing valuable input on product improvements.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-10504",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-29T13:05:11.108097Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-29T13:05:14.517Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Terra AC wallbox",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "1.8.33",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB acknowledges and thanks Ryo Kato for responsibly disclosing the vulnerabilities and providing valuable input on  product improvements."
            }
          ],
          "datePublic": "2025-09-28T04:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.\u003cp\u003eThis issue affects Terra AC wallbox: through 1.8.33.\u003c/p\u003e"
                }
              ],
              "value": "Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NO",
                "Recovery": "AUTOMATIC",
                "Safety": "NEGLIGIBLE",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "DIFFUSE",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "LOW"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-16T06:22:01.300Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8107\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Heap Memory Corruption Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-10504",
        "datePublished": "2025-09-29T04:12:18.599Z",
        "dateReserved": "2025-09-16T06:05:51.851Z",
        "dateUpdated": "2025-10-16T06:22:01.300Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-10207 (GCVE-0-2025-10207)

    Vulnerability from cvelistv5 – Published: 2025-09-18 11:25 – Updated: 2025-09-18 13:32
    VLAI
    Title
    Authenticated File Disclosure/Delete
    Summary
    Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-1287 - Improper Validation of Specified Type of Input
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB FLXEON Affected: 0 , ≤ 9.3.5 (custom)
    Create a notification for this product.
    Date Public
    2025-09-17 00:31
    Credits
    ABB likes to thank Gjoko Krstikj, Zero Science Lab, for reporting the vulnerabilities in responsible disclosure.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-10207",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-18T13:32:31.740377Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-18T13:32:39.633Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FLXEON",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "9.3.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB likes to thank Gjoko Krstikj, Zero Science Lab, for reporting the vulnerabilities in responsible disclosure."
            }
          ],
          "datePublic": "2025-09-17T00:31:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.\u003cp\u003eThis issue affects FLXEON: through 9.3.5.\u003c/p\u003e"
                }
              ],
              "value": "Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1287",
                  "description": "CWE-1287 Improper Validation of Specified Type of Input",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-18T11:25:07.835Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A7121\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Authenticated File Disclosure/Delete",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-10207",
        "datePublished": "2025-09-18T11:25:07.835Z",
        "dateReserved": "2025-09-10T08:25:16.701Z",
        "dateUpdated": "2025-09-18T13:32:39.633Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-48851 (GCVE-0-2024-48851)

    Vulnerability from cvelistv5 – Published: 2025-09-18 11:17 – Updated: 2025-09-18 13:34
    VLAI
    Title
    Remote Code Execution
    Summary
    Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.A remote code execution is possible due to an improper input validation. This issue affects FLXEON: through 9.3.5.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-1287 - Improper Validation of Specified Type of Input
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB FLXEON Affected: 0 , ≤ 9.3.5 (custom)
    Create a notification for this product.
    Date Public
    2025-09-17 00:31
    Credits
    ABB likes to thank Gjoko Krstikj, Zero Science Lab, for reporting the vulnerabilities in responsible disclosure.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-48851",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-18T13:33:47.578655Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-18T13:34:37.756Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FLXEON",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "9.3.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB likes to thank Gjoko Krstikj, Zero Science Lab, for reporting the vulnerabilities in responsible disclosure."
            }
          ],
          "datePublic": "2025-09-17T00:31:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.\u003cp\u003eA remote code execution is possible due to an improper input validation.\n\n\u003cbr\u003e\u003c/p\u003e\u003cp\u003eThis issue affects FLXEON: through 9.3.5.\u003c/p\u003e"
                }
              ],
              "value": "Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.A remote code execution is possible due to an improper input validation.\n\n\n\n\nThis issue affects FLXEON: through 9.3.5."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1287",
                  "description": "CWE-1287 Improper Validation of Specified Type of Input",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-18T11:26:22.835Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A7121\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Remote Code Execution",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2024-48851",
        "datePublished": "2025-09-18T11:17:35.712Z",
        "dateReserved": "2024-10-08T17:31:47.585Z",
        "dateUpdated": "2025-09-18T13:34:37.756Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-10205 (GCVE-0-2025-10205)

    Vulnerability from cvelistv5 – Published: 2025-09-17 14:51 – Updated: 2025-09-18 11:22
    VLAI
    Title
    Predictable Salt and Weak Hashing Algorithm
    Summary
    Use of a One-Way Hash with a Predictable Salt vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5. and newer versions
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-759 - Use of a One-Way Hash with a Predictable Salt
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB FLXEON Affected: 0 , ≤ 9.3.5 (custom)
    Create a notification for this product.
    Date Public
    2025-09-17 00:31
    Credits
    ABB likes to thank Gjoko Krstikj, Zero Science Lab, for reporting the vulnerabilities in responsible disclosure.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-10205",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-17T15:11:12.782795Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-17T15:11:18.744Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FLXEON",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "9.3.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB likes to thank Gjoko Krstikj, Zero Science Lab, for reporting the vulnerabilities in responsible disclosure."
            }
          ],
          "datePublic": "2025-09-17T00:31:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of a One-Way Hash with a Predictable Salt vulnerability in ABB FLXEON.\u003cp\u003eThis issue affects FLXEON: through 9.3.5.\u0026nbsp;and newer versions\n\n\u003c/p\u003e"
                }
              ],
              "value": "Use of a One-Way Hash with a Predictable Salt vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5.\u00a0and newer versions"
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-759",
                  "description": "CWE-759 Use of a One-Way Hash with a Predictable Salt",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-18T11:22:31.377Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A7121\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Predictable Salt and Weak Hashing Algorithm",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-10205",
        "datePublished": "2025-09-17T14:51:52.567Z",
        "dateReserved": "2025-09-10T08:25:11.557Z",
        "dateUpdated": "2025-09-18T11:22:31.377Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-48842 (GCVE-0-2024-48842)

    Vulnerability from cvelistv5 – Published: 2025-09-17 14:48 – Updated: 2025-09-17 15:05
    VLAI
    Title
    Hardcoded passwords
    Summary
    Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB FLXEON Affected: 0 , ≤ 9.3.5 (custom)
    Create a notification for this product.
    Date Public
    2025-09-17 00:31
    Credits
    ABB likes to thank Gjoko Krstikj, Zero Science Lab, for reporting the vulnerabilities in responsible disclosure.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-48842",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-17T15:05:36.275227Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-17T15:05:59.325Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FLXEON",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "9.3.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB likes to thank Gjoko Krstikj, Zero Science Lab, for reporting the vulnerabilities in responsible disclosure."
            }
          ],
          "datePublic": "2025-09-17T00:31:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of Hard-coded Credentials vulnerability in ABB FLXEON.\u003cp\u003eThis issue affects FLXEON: through 9.3.5 and newer versions\u003c/p\u003e"
                }
              ],
              "value": "Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions"
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "PHYSICAL",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:P/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-17T14:48:21.712Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A7121\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Hardcoded passwords",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2024-48842",
        "datePublished": "2025-09-17T14:48:21.712Z",
        "dateReserved": "2024-10-08T17:24:01.444Z",
        "dateUpdated": "2025-09-17T15:05:59.325Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-8754 (GCVE-0-2025-8754)

    Vulnerability from cvelistv5 – Published: 2025-08-13 17:40 – Updated: 2025-08-13 17:53
    VLAI
    Title
    ABB AbilityTM zenon Remote Transport Vulnerability
    Summary
    Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB ABB AbilityTM zenon Affected: 7.50 , ≤ 14 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-8754",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-13T17:53:23.312601Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-13T17:53:43.102Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ABB AbilityTM zenon",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "14",
                  "status": "affected",
                  "version": "7.50",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.\u003cp\u003eThis issue affects ABB AbilityTM zenon: from 7.50 through 14.\u003c/p\u003e"
                }
              ],
              "value": "Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NO",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/AU:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-13T17:40:34.706Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA002743\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "ABB AbilityTM zenon Remote Transport Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-8754",
        "datePublished": "2025-08-13T17:40:34.706Z",
        "dateReserved": "2025-08-08T13:25:56.086Z",
        "dateUpdated": "2025-08-13T17:53:43.102Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-7679 (GCVE-0-2025-7679)

    Vulnerability from cvelistv5 – Published: 2025-08-11 18:36 – Updated: 2025-09-04 00:35
    VLAI
    Title
    Session ID Basic Auth Bypass
    Summary
    The ASPECT system allows users to bypass authentication. This issue affects all versions of ASPECT
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB Aspect Affected: All versions (custom)
    Create a notification for this product.
    Credits
    ABB acknowledges Gjoko Krstikj, Zero Science Lab, for reporting vulnerabilities in responsible disclosure.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7679",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-11T18:56:29.497213Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-11T18:56:43.287Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Aspect",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB acknowledges Gjoko Krstikj, Zero Science Lab, for reporting vulnerabilities in responsible disclosure."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe ASPECT system allows users to bypass authentication.\u003cbr\u003e This issue affects all versions of ASPECT\u003c/span\u003e\n\n\u003cp\u003e\u003c/p\u003e"
                }
              ],
              "value": "The ASPECT system allows users to bypass authentication.\n This issue affects all versions of ASPECT"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-04T00:35:39.266Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A4462\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Session ID Basic Auth Bypass",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-7679",
        "datePublished": "2025-08-11T18:36:26.588Z",
        "dateReserved": "2025-07-15T14:54:37.423Z",
        "dateUpdated": "2025-09-04T00:35:39.266Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-7677 (GCVE-0-2025-7677)

    Vulnerability from cvelistv5 – Published: 2025-08-11 18:36 – Updated: 2025-09-08 15:14
    VLAI
    Title
    DOS attack possible
    Summary
    A denial-of-service (DoS) attack is possible if access to the local network is provided to unauthorized users. This is due to a buffer copy issue that may lead to a software crash. This issue affects all versions of ASPECT.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Assigner
    ABB
    Impacted products
    Vendor Product Version
    ABB Aspect Affected: All versions (custom)
    Create a notification for this product.
    Credits
    ABB acknowledges Gjoko Krstikj, Zero Science Lab, for reporting vulnerabilities in responsible disclosure.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7677",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-11T18:59:07.884450Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-11T18:59:43.160Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Aspect",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB acknowledges Gjoko Krstikj, Zero Science Lab, for reporting vulnerabilities in responsible disclosure."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA denial-of-service (DoS) attack is possible if access to the local network is provided to unauthorized users. This is due to a buffer copy issue that may lead to a software crash. \u003cbr\u003eThis issue affects all versions of ASPECT.\u003c/span\u003e"
                }
              ],
              "value": "A denial-of-service (DoS) attack is possible if access to the local network is provided to unauthorized users. This is due to a buffer copy issue that may lead to a software crash. \nThis issue affects all versions of ASPECT."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-08T15:14:32.740Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A4462\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "DOS attack possible",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-7677",
        "datePublished": "2025-08-11T18:36:23.850Z",
        "dateReserved": "2025-07-15T14:54:34.544Z",
        "dateUpdated": "2025-09-08T15:14:32.740Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-53191 (GCVE-0-2025-53191)

    Vulnerability from cvelistv5 – Published: 2025-08-11 18:29 – Updated: 2025-08-21 10:28
    VLAI

    This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.

    Show details on NVD website

    {
      "containers": {
        "cna": {
          "providerMetadata": {
            "dateUpdated": "2025-08-21T10:28:28.154Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "rejectedReasons": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This CVE ID has been rejected or withdrawn by its CVE Numbering Authority."
                }
              ],
              "value": "This CVE ID has been rejected or withdrawn by its CVE Numbering Authority."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-53191",
        "datePublished": "2025-08-11T18:29:03.065Z",
        "dateRejected": "2025-08-21T10:28:28.154Z",
        "dateReserved": "2025-06-27T10:01:27.161Z",
        "dateUpdated": "2025-08-21T10:28:28.154Z",
        "state": "REJECTED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }