CWE-798
Allowed-with-ReviewUse of Hard-coded Credentials
Abstraction: Base · Status: Draft
The product contains hard-coded credentials, such as a password or cryptographic key.
2174 vulnerabilities reference this CWE, most recent first.
CVE-2025-27255 (GCVE-0-2025-27255)
Vulnerability from cvelistv5 – Published: 2025-03-10 09:05 – Updated: 2025-03-12 11:10- CWE-798 - Use of Hard-coded Credentials
| Vendor | Product | Version | |
|---|---|---|---|
| GE Vernova | EnerVista UR Setup |
Affected:
8.42
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27255",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-10T14:02:30.485876Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-10T14:03:06.938Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EnerVista UR Setup",
"vendor": "GE Vernova",
"versions": [
{
"status": "affected",
"version": "8.42",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Use of Hard-coded Credentials vulnerability in GE Vernova EnerVista UR Setup allows Privilege Escalation. The local user database is encrypted using an hardcoded password retrievable by an attacker analyzing the application code."
}
],
"value": "Use of Hard-coded Credentials vulnerability in GE Vernova EnerVista UR Setup allows Privilege Escalation. The local user database is encrypted using an hardcoded password retrievable by an attacker analyzing the application code."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-12T11:10:21.030Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily\u0026type=21\u0026file=76"
},
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-27255"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2025-27255",
"datePublished": "2025-03-10T09:05:17.222Z",
"dateReserved": "2025-02-21T08:32:26.973Z",
"dateUpdated": "2025-03-12T11:10:21.030Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-26410 (GCVE-0-2025-26410)
Vulnerability from cvelistv5 – Published: 2025-02-11 09:20 – Updated: 2025-11-03 21:12- CWE-798 - Use of Hard-coded Credentials
| URL | Tags |
|---|---|
| https://r.sec-consult.com/wattsense | third-party-advisory |
| https://support.wattsense.com/hc/en-150/articles/… | release-notes |
| http://seclists.org/fulldisclosure/2025/Feb/9 |
| Vendor | Product | Version | |
|---|---|---|---|
| Wattsense | Wattsense Bridge |
Affected:
0 , < 6.4.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-26410",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-11T14:35:57.904824Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T18:27:29.653Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T21:12:53.153Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Feb/9"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Wattsense Bridge",
"vendor": "Wattsense",
"versions": [
{
"lessThan": "6.4.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Constantin Schieber-Kn\u00f6bl | SEC Consult Vulnerability Lab"
},
{
"lang": "en",
"type": "finder",
"value": "Stefan Schweighofer | SEC Consult Vulnerability Lab"
},
{
"lang": "en",
"type": "finder",
"value": "Steffen Robertz | SEC Consult Vulnerability Lab"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP \u0026gt;= 6.4.1.\u003cbr\u003e"
}
],
"value": "The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP \u003e= 6.4.1."
}
],
"impacts": [
{
"capecId": "CAPEC-653",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-653 Use of Known Operating System Credentials"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-11T09:20:22.708Z",
"orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"shortName": "SEC-VLab"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://r.sec-consult.com/wattsense"
},
{
"tags": [
"release-notes"
],
"url": "https://support.wattsense.com/hc/en-150/articles/13366066529437-Release-Notes"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This issue is fixed in recent firmware versions BSP \u0026gt;= 6.4.1."
}
],
"value": "This issue is fixed in recent firmware versions BSP \u003e= 6.4.1."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Weak Hard-coded Credentials",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
"assignerShortName": "SEC-VLab",
"cveId": "CVE-2025-26410",
"datePublished": "2025-02-11T09:20:22.708Z",
"dateReserved": "2025-02-10T07:48:38.352Z",
"dateUpdated": "2025-11-03T21:12:53.153Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-26398 (GCVE-0-2025-26398)
Vulnerability from cvelistv5 – Published: 2025-08-12 08:10 – Updated: 2026-02-26 17:49- CWE-798 - Use of Hard-coded Credentials
| Vendor | Product | Version | |
|---|---|---|---|
| SolarWinds | Database Performance Analyzer |
Affected:
2025.2 and below
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-26398",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-13T15:03:59.169314Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-26T17:49:42.688Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "Database Performance Analyzer",
"vendor": "SolarWinds",
"versions": [
{
"status": "affected",
"version": "2025.2 and below"
}
]
}
],
"datePublic": "2025-08-11T23:59:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSolarWinds Database Performance Analyzer was found to \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003econtain\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e a hard-coded cryptographic key. If exploited, this vulnerability could lead to a machine-in-the-middle (\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eM\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eI\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eTM\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e) attack against users. This vulnerability requires \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eadditional\u003c/span\u003e \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003esoftware not installed by \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003edefault,\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e local access to the server and administrator level privileges\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e on the host.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "SolarWinds Database Performance Analyzer was found to contain a hard-coded cryptographic key. If exploited, this vulnerability could lead to a machine-in-the-middle (MITM) attack against users. This vulnerability requires additional software not installed by default, local access to the server and administrator level privileges on the host."
}
],
"impacts": [
{
"capecId": "CAPEC-21",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-21 Exploitation of Trusted Credentials"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T08:10:54.116Z",
"orgId": "49f11609-934d-4621-84e6-e02e032104d6",
"shortName": "SolarWinds"
},
"references": [
{
"url": "https://www.solarwinds.com/trust-center/security-advisories/CVE-2025-26398"
},
{
"url": "https://documentation.solarwinds.com/en/success_center/dpa/content/release_notes/dpa_2025-3_release_notes.htm"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "SolarWinds recommends that customers upgrade to SolarWinds \n\n Database Performance Analyzer 2025.3\n\n as soon as it becomes available.\n\n\u003cbr\u003e"
}
],
"value": "SolarWinds recommends that customers upgrade to SolarWinds \n\n Database Performance Analyzer 2025.3\n\n as soon as it becomes available."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "SolarWinds Database Performance Analyzer Hard-coded Cryptographic Key Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
"assignerShortName": "SolarWinds",
"cveId": "CVE-2025-26398",
"datePublished": "2025-08-12T08:10:54.116Z",
"dateReserved": "2025-02-08T00:19:09.395Z",
"dateUpdated": "2026-02-26T17:49:42.688Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-23179 (GCVE-0-2025-23179)
Vulnerability from cvelistv5 – Published: 2025-04-29 16:09 – Updated: 2025-04-29 17:56- CWE-798 - Use of Hard-coded Credentials
| Vendor | Product | Version | |
|---|---|---|---|
| Ribbon Communications | Apollo 9608 |
Affected:
v9.6R3
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-23179",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-29T17:55:28.041990Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-29T17:56:36.747Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Apollo 9608",
"vendor": "Ribbon Communications",
"versions": [
{
"status": "affected",
"version": "v9.6R3"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Pierpaolo Santucci"
}
],
"datePublic": "2025-04-29T16:06:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-798: Use of Hard-coded Credentials"
}
],
"value": "CWE-798: Use of Hard-coded Credentials"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-29T16:09:12.121Z",
"orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
"shortName": "INCD"
},
"references": [
{
"url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to v13R1 or later"
}
],
"value": "Upgrade to v13R1 or later"
}
],
"source": {
"advisory": "ILVN-2025-0225",
"discovery": "UNKNOWN"
},
"title": "Ribbon Communications - CWE-798: Use of Hard-coded Credentials",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
"assignerShortName": "INCD",
"cveId": "CVE-2025-23179",
"datePublished": "2025-04-29T16:09:12.121Z",
"dateReserved": "2025-01-12T08:45:19.974Z",
"dateUpdated": "2025-04-29T17:56:36.747Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-20309 (GCVE-0-2025-20309)
Vulnerability from cvelistv5 – Published: 2025-07-02 16:39 – Updated: 2026-02-26 18:27- CWE-798 - Use of Hard-coded Credentials
| Vendor | Product | Version | |
|---|---|---|---|
| Cisco | Cisco Unified Communications Manager |
Affected:
15.0.1.13010-1
Affected: 15.0.1.13011-1 Affected: 15.0.1.13012-1 Affected: 15.0.1.13013-1 Affected: 15.0.1.13014-1 Affected: 15.0.1.13015-1 Affected: 15.0.1.13016-1 Affected: 15.0.1.13017-1 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-20309",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-03T03:55:37.641117Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-26T18:27:57.479Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Cisco Unified Communications Manager",
"vendor": "Cisco",
"versions": [
{
"status": "affected",
"version": "15.0.1.13010-1"
},
{
"status": "affected",
"version": "15.0.1.13011-1"
},
{
"status": "affected",
"version": "15.0.1.13012-1"
},
{
"status": "affected",
"version": "15.0.1.13013-1"
},
{
"status": "affected",
"version": "15.0.1.13014-1"
},
{
"status": "affected",
"version": "15.0.1.13015-1"
},
{
"status": "affected",
"version": "15.0.1.13016-1"
},
{
"status": "affected",
"version": "15.0.1.13017-1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in Cisco Unified Communications Manager (Unified CM) and Cisco Unified Communications Manager Session Management Edition (Unified CM SME) could allow an unauthenticated, remote attacker to log in to an affected device using the root account, which has default, static credentials that cannot be changed or deleted.\r\n\r\nThis vulnerability is due to the presence of static user credentials for the root account that are reserved for use during development. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco PSIRT is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "cvssV3_1"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "Use of Hard-coded Credentials",
"lang": "en",
"type": "cwe"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-02T19:19:10.516Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "cisco-sa-cucm-ssh-m4UBdpE7",
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-cucm-ssh-m4UBdpE7"
}
],
"source": {
"advisory": "cisco-sa-cucm-ssh-m4UBdpE7",
"defects": [
"CSCwp27755"
],
"discovery": "INTERNAL"
},
"title": "Cisco Unified Communications Manager Static SSH Credentials Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2025-20309",
"datePublished": "2025-07-02T16:39:40.392Z",
"dateReserved": "2024-10-10T19:15:13.253Z",
"dateUpdated": "2026-02-26T18:27:57.479Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-20188 (GCVE-0-2025-20188)
Vulnerability from cvelistv5 – Published: 2025-05-07 17:34 – Updated: 2025-06-06 16:24- CWE-798 - Use of Hard-coded Credentials
| Vendor | Product | Version | |
|---|---|---|---|
| Cisco | Cisco IOS XE Software |
Affected:
17.11.1
Affected: 17.12.1 Affected: 17.12.2 Affected: 17.12.3 Affected: 17.13.1 Affected: 17.14.1 Affected: 17.11.99SW |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-20188",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-04T13:12:24.831348Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-04T13:14:28.117Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://horizon3.ai/attack-research/attack-blogs/cisco-ios-xe-wlc-arbitrary-file-upload-vulnerability-cve-2025-20188-analysis/"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco IOS XE Software",
"vendor": "Cisco",
"versions": [
{
"status": "affected",
"version": "17.11.1"
},
{
"status": "affected",
"version": "17.12.1"
},
{
"status": "affected",
"version": "17.12.2"
},
{
"status": "affected",
"version": "17.12.3"
},
{
"status": "affected",
"version": "17.13.1"
},
{
"status": "affected",
"version": "17.14.1"
},
{
"status": "affected",
"version": "17.11.99SW"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the Out-of-Band Access Point (AP) Image Download, the Clean Air Spectral Recording, and the client debug bundles features of Cisco IOS XE Software for Wireless LAN Controllers (WLCs) could allow an unauthenticated, remote attacker to upload arbitrary files to an affected system.\r\n\r This vulnerability is due to the presence of a hard-coded JSON Web Token (JWT) on an affected system. An attacker could exploit this vulnerability by sending crafted HTTPS requests to the AP file upload interface. A successful exploit could allow the attacker to upload files, perform path traversal, and execute arbitrary commands with root privileges."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco PSIRT is aware that proof-of-concept exploit code is available for the vulnerability that is described in this advisory.\r\n\r\nThe Cisco PSIRT is not aware of any malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "cvssV3_1"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "Use of Hard-coded Credentials",
"lang": "en",
"type": "cwe"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-06T16:24:05.256Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "cisco-sa-wlc-file-uplpd-rHZG9UfC",
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wlc-file-uplpd-rHZG9UfC"
}
],
"source": {
"advisory": "cisco-sa-wlc-file-uplpd-rHZG9UfC",
"defects": [
"CSCwk33139"
],
"discovery": "INTERNAL"
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2025-20188",
"datePublished": "2025-05-07T17:34:36.871Z",
"dateReserved": "2024-10-10T19:15:13.226Z",
"dateUpdated": "2025-06-06T16:24:05.256Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-15371 (GCVE-0-2025-15371)
Vulnerability from cvelistv5 – Published: 2025-12-31 01:02 – Updated: 2026-01-02 14:38| URL | Tags |
|---|---|
| https://vuldb.com/?id.339075 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.339075 | signaturepermissions-required |
| https://vuldb.com/?submit.727155 | third-party-advisory |
| https://vuldb.com/?submit.727283 | third-party-advisory |
| https://vuldb.com/?submit.727284 | third-party-advisory |
| https://vuldb.com/?submit.727285 | third-party-advisory |
| https://vuldb.com/?submit.727302 | third-party-advisory |
| https://vuldb.com/?submit.727305 | third-party-advisory |
| https://vuldb.com/?submit.727306 | third-party-advisory |
| https://github.com/vuln-1/vuln/blob/main/Tenda/i2… | exploit |
| https://www.tenda.com.cn/ | product |
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | i24 |
Affected:
1.0.0.35
Affected: 3.0.0.8(4008) Affected: 04.03.01.49 Affected: 04.05.01.15 Affected: 04.08.01.28 Affected: 16.01.8.5 Affected: 65.10.15.6 |
|
| Tenda | 4G03 Pro |
Affected:
1.0.0.35
Affected: 3.0.0.8(4008) Affected: 04.03.01.49 Affected: 04.05.01.15 Affected: 04.08.01.28 Affected: 16.01.8.5 Affected: 65.10.15.6 |
|
| Tenda | 4G05 |
Affected:
1.0.0.35
Affected: 3.0.0.8(4008) Affected: 04.03.01.49 Affected: 04.05.01.15 Affected: 04.08.01.28 Affected: 16.01.8.5 Affected: 65.10.15.6 |
|
| Tenda | 4G08 |
Affected:
1.0.0.35
Affected: 3.0.0.8(4008) Affected: 04.03.01.49 Affected: 04.05.01.15 Affected: 04.08.01.28 Affected: 16.01.8.5 Affected: 65.10.15.6 |
|
| Tenda | G0-8G-PoE |
Affected:
1.0.0.35
Affected: 3.0.0.8(4008) Affected: 04.03.01.49 Affected: 04.05.01.15 Affected: 04.08.01.28 Affected: 16.01.8.5 Affected: 65.10.15.6 |
|
| Tenda | Nova MW5G |
Affected:
1.0.0.35
Affected: 3.0.0.8(4008) Affected: 04.03.01.49 Affected: 04.05.01.15 Affected: 04.08.01.28 Affected: 16.01.8.5 Affected: 65.10.15.6 |
|
| Tenda | TEG5328F |
Affected:
1.0.0.35
Affected: 3.0.0.8(4008) Affected: 04.03.01.49 Affected: 04.05.01.15 Affected: 04.08.01.28 Affected: 16.01.8.5 Affected: 65.10.15.6 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-15371",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-02T14:22:55.128847Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-02T14:38:01.600Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Shadow File"
],
"product": "i24",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.35"
},
{
"status": "affected",
"version": "3.0.0.8(4008)"
},
{
"status": "affected",
"version": "04.03.01.49"
},
{
"status": "affected",
"version": "04.05.01.15"
},
{
"status": "affected",
"version": "04.08.01.28"
},
{
"status": "affected",
"version": "16.01.8.5"
},
{
"status": "affected",
"version": "65.10.15.6"
}
]
},
{
"modules": [
"Shadow File"
],
"product": "4G03 Pro",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.35"
},
{
"status": "affected",
"version": "3.0.0.8(4008)"
},
{
"status": "affected",
"version": "04.03.01.49"
},
{
"status": "affected",
"version": "04.05.01.15"
},
{
"status": "affected",
"version": "04.08.01.28"
},
{
"status": "affected",
"version": "16.01.8.5"
},
{
"status": "affected",
"version": "65.10.15.6"
}
]
},
{
"modules": [
"Shadow File"
],
"product": "4G05",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.35"
},
{
"status": "affected",
"version": "3.0.0.8(4008)"
},
{
"status": "affected",
"version": "04.03.01.49"
},
{
"status": "affected",
"version": "04.05.01.15"
},
{
"status": "affected",
"version": "04.08.01.28"
},
{
"status": "affected",
"version": "16.01.8.5"
},
{
"status": "affected",
"version": "65.10.15.6"
}
]
},
{
"modules": [
"Shadow File"
],
"product": "4G08",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.35"
},
{
"status": "affected",
"version": "3.0.0.8(4008)"
},
{
"status": "affected",
"version": "04.03.01.49"
},
{
"status": "affected",
"version": "04.05.01.15"
},
{
"status": "affected",
"version": "04.08.01.28"
},
{
"status": "affected",
"version": "16.01.8.5"
},
{
"status": "affected",
"version": "65.10.15.6"
}
]
},
{
"modules": [
"Shadow File"
],
"product": "G0-8G-PoE",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.35"
},
{
"status": "affected",
"version": "3.0.0.8(4008)"
},
{
"status": "affected",
"version": "04.03.01.49"
},
{
"status": "affected",
"version": "04.05.01.15"
},
{
"status": "affected",
"version": "04.08.01.28"
},
{
"status": "affected",
"version": "16.01.8.5"
},
{
"status": "affected",
"version": "65.10.15.6"
}
]
},
{
"modules": [
"Shadow File"
],
"product": "Nova MW5G",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.35"
},
{
"status": "affected",
"version": "3.0.0.8(4008)"
},
{
"status": "affected",
"version": "04.03.01.49"
},
{
"status": "affected",
"version": "04.05.01.15"
},
{
"status": "affected",
"version": "04.08.01.28"
},
{
"status": "affected",
"version": "16.01.8.5"
},
{
"status": "affected",
"version": "65.10.15.6"
}
]
},
{
"modules": [
"Shadow File"
],
"product": "TEG5328F",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.35"
},
{
"status": "affected",
"version": "3.0.0.8(4008)"
},
{
"status": "affected",
"version": "04.03.01.49"
},
{
"status": "affected",
"version": "04.05.01.15"
},
{
"status": "affected",
"version": "04.08.01.28"
},
{
"status": "affected",
"version": "16.01.8.5"
},
{
"status": "affected",
"version": "65.10.15.6"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "vlun-1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda i24, 4G03 Pro, 4G05, 4G08, G0-8G-PoE, Nova MW5G and TEG5328F up to 65.10.15.6. Affected is an unknown function of the component Shadow File. Such manipulation with the input Fireitup leads to hard-coded credentials. An attack has to be approached locally. The exploit has been disclosed to the public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.8,
"vectorString": "AV:L/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "Use of Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-31T01:02:06.989Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-339075 | Tenda i24 Shadow File hard-coded credentials",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.339075"
},
{
"name": "VDB-339075 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.339075"
},
{
"name": "Submit #727155 | Tenda Tenda i24v3.0 V3.0.0.8(4008) V3.0.0.8(4008) Hard-coded Credentials",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.727155"
},
{
"name": "Submit #727283 | Tenda 4G03ProV1.0re V04.03.01.49 Hard-coded Credentials (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.727283"
},
{
"name": "Submit #727284 | Tenda 4G05V1.0re V04.05.01.15 Hard-coded Credentials (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.727284"
},
{
"name": "Submit #727285 | Tenda 4G08V1.0re V04.08.01.28 Hard-coded Credentials (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.727285"
},
{
"name": "Submit #727302 | Tenda G0-8G-PoEV2.0si V16.01.8.5 Hard-coded Credentials (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.727302"
},
{
"name": "Submit #727305 | Tenda MW5GV1.0re V1.0.0.35 Hard-coded Credentials (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.727305"
},
{
"name": "Submit #727306 | Tenda TEG5328FV1.0ma V65.10.15.6 Hard-coded Credentials (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.727306"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/vuln-1/vuln/blob/main/Tenda/i24v3.0_V3.0.0.8/report-1.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-12-30T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-12-30T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-12-30T19:37:46.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda i24 Shadow File hard-coded credentials"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-15371",
"datePublished": "2025-12-31T01:02:06.989Z",
"dateReserved": "2025-12-30T17:35:13.980Z",
"dateUpdated": "2026-01-02T14:38:01.600Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-14126 (GCVE-0-2025-14126)
Vulnerability from cvelistv5 – Published: 2025-12-06 10:02 – Updated: 2025-12-08 17:14| URL | Tags |
|---|---|
| https://vuldb.com/?id.334521 | vdb-entry |
| https://vuldb.com/?ctiid.334521 | signaturepermissions-required |
| https://vuldb.com/?submit.697498 | third-party-advisory |
| https://youtu.be/o8rfjSlpRxY | exploitmedia-coverage |
| Vendor | Product | Version | |
|---|---|---|---|
| TOZED | ZLT M30S |
Affected:
1.47
Affected: 3.09.06 |
|
| TOZED | ZLT M30S PRO |
Affected:
1.47
Affected: 3.09.06 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-14126",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-08T17:07:30.732362Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-08T17:14:25.265Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Web Interface"
],
"product": "ZLT M30S",
"vendor": "TOZED",
"versions": [
{
"status": "affected",
"version": "1.47"
},
{
"status": "affected",
"version": "3.09.06"
}
]
},
{
"modules": [
"Web Interface"
],
"product": "ZLT M30S PRO",
"vendor": "TOZED",
"versions": [
{
"status": "affected",
"version": "1.47"
},
{
"status": "affected",
"version": "3.09.06"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "S33K3R (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in TOZED ZLT M30S and ZLT M30S PRO 1.47/3.09.06. Affected is an unknown function of the component Web Interface. Such manipulation leads to hard-coded credentials. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "Use of Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-06T10:02:05.279Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-334521 | TOZED ZLT M30S/ZLT M30S PRO Web hard-coded credentials",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.334521"
},
{
"name": "VDB-334521 | CTI Indicators (IOB, IOC, TTP)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.334521"
},
{
"name": "Submit #697498 | ZLT M30S \u0026 M30S PRO MTNNGRM30S_1.47, M30SPRO_3.09.06 (Other versions might be vulnerable) Backdoor Credentials",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.697498"
},
{
"tags": [
"exploit",
"media-coverage"
],
"url": "https://youtu.be/o8rfjSlpRxY"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-12-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-12-05T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-12-05T18:03:30.000Z",
"value": "VulDB entry last update"
}
],
"title": "TOZED ZLT M30S/ZLT M30S PRO Web hard-coded credentials"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-14126",
"datePublished": "2025-12-06T10:02:05.279Z",
"dateReserved": "2025-12-05T16:58:25.370Z",
"dateUpdated": "2025-12-08T17:14:25.265Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-14115 (GCVE-0-2025-14115)
Vulnerability from cvelistv5 – Published: 2026-01-20 14:59 – Updated: 2026-02-26 14:44- CWE-798 - Use of Hard-coded Credentials
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7257143 | vendor-advisorypatch |
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Sterling Connect:Direct for UNIX Container |
Affected:
6.3.0.0 , ≤ 6.3.0.6 Interim Fix 016
(semver)
Affected: 6.4.0.0 , ≤ 6.4.0.3 Interim Fix 019 (semver) cpe:2.3:a:ibm:sterling_connectdirect_for_unix_container:6.3.0.0:*:*:*:*:*:*:* cpe:2.3:a:ibm:sterling_connectdirect_for_unix_container:6.3.0.6:interim_fix_016:*:*:*:*:*:* cpe:2.3:a:ibm:sterling_connectdirect_for_unix_container:6.4.0.0:*:*:*:*:*:*:* cpe:2.3:a:ibm:sterling_connectdirect_for_unix_container:6.4.0.3:interim_fix_019:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-14115",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-21T04:55:23.620986Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-26T14:44:44.315Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:ibm:sterling_connectdirect_for_unix_container:6.3.0.0:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:sterling_connectdirect_for_unix_container:6.3.0.6:interim_fix_016:*:*:*:*:*:*",
"cpe:2.3:a:ibm:sterling_connectdirect_for_unix_container:6.4.0.0:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:sterling_connectdirect_for_unix_container:6.4.0.3:interim_fix_019:*:*:*:*:*:*"
],
"product": "Sterling Connect:Direct for UNIX Container",
"vendor": "IBM",
"versions": [
{
"lessThanOrEqual": "6.3.0.6 Interim Fix 016",
"status": "affected",
"version": "6.3.0.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "6.4.0.3 Interim Fix 019",
"status": "affected",
"version": "6.4.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Sterling Connect:Direct for UNIX Container 6.3.0.0 through 6.3.0.6 Interim Fix 016, and 6.4.0.0 through 6.4.0.3 Interim Fix 019 IBM\u00ae Sterling Connect:Direct for UNIX contains hard-coded credentials, such as a password or cryptographic key, which it uses for\u0026nbsp;its own inbound authentication, outbound communication to external components, or encryption of\u0026nbsp;internal data.\u003c/p\u003e"
}
],
"value": "IBM Sterling Connect:Direct for UNIX Container 6.3.0.0 through 6.3.0.6 Interim Fix 016, and 6.4.0.0 through 6.4.0.3 Interim Fix 019 IBM\u00ae Sterling Connect:Direct for UNIX contains hard-coded credentials, such as a password or cryptographic key, which it uses for\u00a0its own inbound authentication, outbound communication to external components, or encryption of\u00a0internal data."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-20T14:59:15.938Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7257143"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM strongly recommends addressing the vulnerability now by upgrading. Product(s) Version(s) APAR Remediation/Fix IBM Sterling Connect:Direct for UNIX Container 6.3.0.0 to 6.3.0.6_iFix016 IT48880 Apply 6.3.0.6_iFix017, see Downloading the IBM Sterling Connect:Direct for Unix Container IBM Sterling Connect:Direct for UNIX Container 6.4.0.0 to 6.4.0.3_iFix019 IT48880 Apply 6.4.0.4, see Downloading the IBM Sterling Connect:Direct for Unix Container For unsupported versions IBM recommends upgrading to a fixed, supported version of the product.\u003c/p\u003e"
}
],
"value": "IBM strongly recommends addressing the vulnerability now by upgrading. Product(s) Version(s) APAR Remediation/Fix IBM Sterling Connect:Direct for UNIX Container 6.3.0.0 to 6.3.0.6_iFix016 IT48880 Apply 6.3.0.6_iFix017, see Downloading the IBM Sterling Connect:Direct for Unix Container IBM Sterling Connect:Direct for UNIX Container 6.4.0.0 to 6.4.0.3_iFix019 IT48880 Apply 6.4.0.4, see Downloading the IBM Sterling Connect:Direct for Unix Container For unsupported versions IBM recommends upgrading to a fixed, supported version of the product."
}
],
"title": "IBM Sterling Connect:Direct for UNIX Container is affected by vulnerability where hard-coded credentials are embeeded in the product for its internal use.",
"x_generator": {
"engine": "ibm-cvegen"
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2025-14115",
"datePublished": "2026-01-20T14:59:15.938Z",
"dateReserved": "2025-12-05T15:14:31.863Z",
"dateUpdated": "2026-02-26T14:44:44.315Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-14096 (GCVE-0-2025-14096)
Vulnerability from cvelistv5 – Published: 2025-12-17 12:19 – Updated: 2025-12-17 14:43| Vendor | Product | Version | |
|---|---|---|---|
| Radiometer Medical Aps | ABL90 FLEX and ABL90 FLEX PLUS Analyzers |
Affected:
Windows 7 Operating system
(Radiometer Customized Windows Operating System)
Affected: Windows XP Operating system (Radiometer Customized Windows Operating System) |
|
| Radiometer Medical Aps | AQT90 FLEX Analyzers |
Affected:
Windows 7 Operating system
(Radiometer Customized Windows Operating System)
Affected: Windows XP Operating system (Radiometer Customized Windows Operating System) |
|
| Radiometer Medical Aps | ABL800 BASIC and ABL800 FLEX analyzers |
Affected:
Windows 7 Operating system
(Radiometer Customized Windows Operating System)
Affected: Windows XP Operating system (Radiometer Customized Windows Operating System) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-14096",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-17T14:42:57.843796Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-17T14:43:16.523Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows XP",
"Windows 7"
],
"product": "ABL90 FLEX and ABL90 FLEX PLUS Analyzers",
"vendor": "Radiometer Medical Aps",
"versions": [
{
"status": "affected",
"version": "Windows 7 Operating system",
"versionType": "Radiometer Customized Windows Operating System"
},
{
"status": "affected",
"version": "Windows XP Operating system",
"versionType": "Radiometer Customized Windows Operating System"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows 7",
"Windows XP"
],
"product": "AQT90 FLEX Analyzers",
"vendor": "Radiometer Medical Aps",
"versions": [
{
"status": "affected",
"version": "Windows 7 Operating system",
"versionType": "Radiometer Customized Windows Operating System"
},
{
"status": "affected",
"version": "Windows XP Operating system",
"versionType": "Radiometer Customized Windows Operating System"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Windows 7",
"Windows XP"
],
"product": "ABL800 BASIC and ABL800 FLEX analyzers",
"vendor": "Radiometer Medical Aps",
"versions": [
{
"status": "affected",
"version": "Windows 7 Operating system",
"versionType": "Radiometer Customized Windows Operating System"
},
{
"status": "affected",
"version": "Windows XP Operating system",
"versionType": "Radiometer Customized Windows Operating System"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Requires physical access to the Analyzer.\n\n\u003cbr\u003e"
}
],
"value": "Requires physical access to the Analyzer."
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Florian Hauser and Fabian Weber from CODE WHITE GmbH"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.\u003cbr\u003e\u003cbr\u003eOther related CVE\u0027s are CVE-2025-14095 \u0026amp; CVE-2025-14097.\u003cbr\u003e\u003cbr\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAffected customers have been informed about this vulnerability. This CVE is being published to provide transparency.\u003c/span\u003e\n\n\u003cbr\u003e\u003cbr\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eRequired Configuration for Exposure:\u003cbr\u003e\u003c/span\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAttacker requires physical access to the analyzer.\u003c/span\u003e\n\n\u003cbr\u003e\u003cbr\u003eTemporary work Around:\u003cbr\u003eOnly authorized people can physically access the analyzer.\u003cbr\u003e\u003cbr\u003ePermanent solution:\u003cbr\u003eLocal Radiometer representatives will contact all affected customers to discuss a permanent solution.\u003cbr\u003e\u003cbr\u003eExploit Status:\u003cbr\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eResearchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication.\u003c/span\u003e\n\n\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.\n\nOther related CVE\u0027s are CVE-2025-14095 \u0026 CVE-2025-14097.\n\n\n\nAffected customers have been informed about this vulnerability. This CVE is being published to provide transparency.\n\n\n\n\n\nRequired Configuration for Exposure:\n\n\nAttacker requires physical access to the analyzer.\n\n\n\nTemporary work Around:\nOnly authorized people can physically access the analyzer.\n\nPermanent solution:\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution.\n\nExploit Status:\n\n\nResearchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication."
}
],
"exploits": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication.\n\n\u003cbr\u003e"
}
],
"value": "Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication."
}
],
"impacts": [
{
"capecId": "CAPEC-69",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-69 \u2014 Target Programs with Elevated Privileges"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-17T13:03:05.696Z",
"orgId": "46b595e9-1acc-41cb-9398-adaf98d37a9b",
"shortName": "Radiometer"
},
"references": [
{
"url": "https://www.radiometer.com/myradiometer"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Local Radiometer representatives will contact all affected customers to discuss a permanent solution.\n\n\n\n\u003cbr\u003e"
}
],
"value": "Local Radiometer representatives will contact all affected customers to discuss a permanent solution."
}
],
"source": {
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2025-12-17T13:01:00.000Z",
"value": "CVE Published"
}
],
"title": "Credential Disclosure vulnerability in Radiometer Products",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Only authorized people can physically access the analyzer.\n\n\n\n\u003cbr\u003e"
}
],
"value": "Only authorized people can physically access the analyzer."
}
],
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "46b595e9-1acc-41cb-9398-adaf98d37a9b",
"assignerShortName": "Radiometer",
"cveId": "CVE-2025-14096",
"datePublished": "2025-12-17T12:19:27.489Z",
"dateReserved": "2025-12-05T10:50:00.566Z",
"dateUpdated": "2025-12-17T14:43:16.523Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Mitigation
- For outbound authentication: store passwords, keys, and other credentials outside of the code in a strongly-protected, encrypted configuration file or database that is protected from access by all outsiders, including other local users on the same system. Properly protect the key (CWE-320). If you cannot use encryption to protect the file, then make sure that the permissions are as restrictive as possible [REF-7].
- In Windows environments, the Encrypted File System (EFS) may provide some protection.
Mitigation
For inbound authentication: Rather than hard-code a default username and password, key, or other authentication credentials for first time logins, utilize a "first login" mode that requires the user to enter a unique strong password or key.
Mitigation
If the product must contain hard-coded credentials or they cannot be removed, perform access control checks and limit which entities can access the feature that requires the hard-coded credentials. For example, a feature might only be enabled through the system console instead of through a network connection.
Mitigation
- For inbound authentication using passwords: apply strong one-way hashes to passwords and store those hashes in a configuration file or database with appropriate access control. That way, theft of the file/database still requires the attacker to try to crack the password. When handling an incoming password during authentication, take the hash of the password and compare it to the saved hash.
- Use randomly assigned salts for each separate hash that is generated. This increases the amount of computation that an attacker needs to conduct a brute-force attack, possibly limiting the effectiveness of the rainbow table method.
Mitigation
- For front-end to back-end connections: Three solutions are possible, although none are complete.
- The first suggestion involves the use of generated passwords or keys that are changed automatically and must be entered at given time intervals by a system administrator. These passwords will be held in memory and only be valid for the time intervals.
- Next, the passwords or keys should be limited at the back end to only performing actions valid for the front end, as opposed to having full access.
- Finally, the messages sent should be tagged and checksummed with time sensitive values so as to prevent replay-style attacks.
CAPEC-191: Read Sensitive Constants Within an Executable
An adversary engages in activities to discover any sensitive constants present within the compiled code of an executable. These constants may include literal ASCII strings within the file itself, or possibly strings hard-coded into particular routines that can be revealed by code refactoring methods including static and dynamic analysis.
CAPEC-70: Try Common or Default Usernames and Passwords
An adversary may try certain common or default usernames and passwords to gain access into the system and perform unauthorized actions. An adversary may try an intelligent brute force using empty passwords, known vendor default credentials, as well as a dictionary of common usernames and passwords. Many vendor products come preconfigured with default (and thus well-known) usernames and passwords that should be deleted prior to usage in a production environment. It is a common mistake to forget to remove these default login credentials. Another problem is that users would pick very simple (common) passwords (e.g. "secret" or "password") that make it easier for the attacker to gain access to the system compared to using a brute force attack or even a dictionary attack using a full dictionary.