CVE-2017-16748 (GCVE-0-2017-16748)

Vulnerability from cvelistv5 – Published: 2018-08-20 21:00 – Updated: 2024-09-17 03:13
VLAI
Summary
An attacker can log into the local Niagara platform (Niagara AX Framework Versions 3.8 and prior or Niagara 4 Framework Versions 4.4 and prior) using a disabled account name and a blank password, granting the attacker administrator access to the Niagara system.
Severity
No CVSS data available.
CWE
  • CWE-287 - IMPROPER AUTHENTICATION CWE-287
Assigner
Impacted products
Vendor Product Version
ICS-CERT Niagara AX Framework and Niagara 4 Framework Affected: Niagara AX Framework Versions 3.8 and prior and Niagara 4 Framework Versions 4.4 and prior
Create a notification for this product.
Date Public
2018-08-16 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:35:21.125Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "105101",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105101"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-03"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-022-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Niagara AX Framework and Niagara 4 Framework",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "Niagara AX Framework Versions 3.8 and prior and Niagara 4 Framework Versions 4.4 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-08-16T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An attacker can log into the local Niagara platform (Niagara AX Framework Versions 3.8 and prior or Niagara 4 Framework Versions 4.4 and prior) using a disabled account name and a blank password, granting the attacker administrator access to the Niagara system."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "IMPROPER AUTHENTICATION CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-04-03T21:11:09.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "105101",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105101"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-03"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-022-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-08-16T00:00:00",
          "ID": "CVE-2017-16748",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Niagara AX Framework and Niagara 4 Framework",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Niagara AX Framework Versions 3.8 and prior and Niagara 4 Framework Versions 4.4 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An attacker can log into the local Niagara platform (Niagara AX Framework Versions 3.8 and prior or Niagara 4 Framework Versions 4.4 and prior) using a disabled account name and a blank password, granting the attacker administrator access to the Niagara system."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER AUTHENTICATION CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "105101",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105101"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-03"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-022-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-022-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-16748",
    "datePublished": "2018-08-20T21:00:00.000Z",
    "dateReserved": "2017-11-09T00:00:00.000Z",
    "dateUpdated": "2024-09-17T03:13:38.893Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-15135 (GCVE-0-2017-15135)

Vulnerability from cvelistv5 – Published: 2018-01-24 15:00 – Updated: 2024-08-05 19:50
VLAI
Summary
It was found that 389-ds-base since 1.3.6.1 up to and including 1.4.0.3 did not always handle internal hash comparison operations correctly during the authentication process. A remote, unauthenticated attacker could potentially use this flaw to bypass the authentication process under very rare and specific circumstances.
Severity
No CVSS data available.
CWE
Assigner
References
URL Tags
http://www.securityfocus.com/bid/102811 vdb-entryx_refsource_BID
https://bugzilla.redhat.com/show_bug.cgi?id=1525628 x_refsource_CONFIRM
https://access.redhat.com/errata/RHSA-2018:0414 vendor-advisoryx_refsource_REDHAT
https://access.redhat.com/errata/RHSA-2018:0515 vendor-advisoryx_refsource_REDHAT
http://lists.opensuse.org/opensuse-security-annou… vendor-advisoryx_refsource_SUSE
Impacted products
Vendor Product Version
Red Hat, Inc. 389-ds-base Affected: since 1.3.6.1 up to and including 1.4.0.3
Create a notification for this product.
Date Public
2017-12-13 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:50:16.357Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "102811",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102811"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=1525628"
          },
          {
            "name": "RHSA-2018:0414",
            "tags": [
              "vendor-advisory",
              "x_refsource_REDHAT",
              "x_transferred"
            ],
            "url": "https://access.redhat.com/errata/RHSA-2018:0414"
          },
          {
            "name": "RHSA-2018:0515",
            "tags": [
              "vendor-advisory",
              "x_refsource_REDHAT",
              "x_transferred"
            ],
            "url": "https://access.redhat.com/errata/RHSA-2018:0515"
          },
          {
            "name": "openSUSE-SU-2019:1397",
            "tags": [
              "vendor-advisory",
              "x_refsource_SUSE",
              "x_transferred"
            ],
            "url": "http://lists.opensuse.org/opensuse-security-announce/2019-05/msg00033.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "389-ds-base",
          "vendor": "Red Hat, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "since 1.3.6.1 up to and including 1.4.0.3"
            }
          ]
        }
      ],
      "datePublic": "2017-12-13T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "It was found that 389-ds-base since 1.3.6.1 up to and including 1.4.0.3 did not always handle internal hash comparison operations correctly during the authentication process. A remote, unauthenticated attacker could potentially use this flaw to bypass the authentication process under very rare and specific circumstances."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-15T20:06:08.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "name": "102811",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102811"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=1525628"
        },
        {
          "name": "RHSA-2018:0414",
          "tags": [
            "vendor-advisory",
            "x_refsource_REDHAT"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2018:0414"
        },
        {
          "name": "RHSA-2018:0515",
          "tags": [
            "vendor-advisory",
            "x_refsource_REDHAT"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2018:0515"
        },
        {
          "name": "openSUSE-SU-2019:1397",
          "tags": [
            "vendor-advisory",
            "x_refsource_SUSE"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2019-05/msg00033.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2017-15135",
    "datePublished": "2018-01-24T15:00:00.000Z",
    "dateReserved": "2017-10-08T00:00:00.000Z",
    "dateUpdated": "2024-08-05T19:50:16.357Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-14026 (GCVE-0-2017-14026)

Vulnerability from cvelistv5 – Published: 2018-09-06 19:00 – Updated: 2024-09-16 23:55
VLAI
Summary
In Ice Qube Thermal Management Center versions prior to version 4.13, the web application does not properly authenticate users which may allow an attacker to gain access to sensitive information.
Severity
No CVSS data available.
CWE
  • CWE-287 - IMPROPER AUTHENTICATION CWE-287
Assigner
References
Impacted products
Vendor Product Version
Ice Qube Thermal Management Center Affected: All versions prior to version 4.13
Create a notification for this product.
Date Public
2018-09-06 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:13:41.469Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-249-01"
          },
          {
            "name": "105303",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105303"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Thermal Management Center",
          "vendor": "Ice Qube",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to version 4.13"
            }
          ]
        }
      ],
      "datePublic": "2018-09-06T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Ice Qube Thermal Management Center versions prior to version 4.13, the web application does not properly authenticate users which may allow an attacker to gain access to sensitive information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "IMPROPER AUTHENTICATION CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-09-11T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-249-01"
        },
        {
          "name": "105303",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105303"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-09-06T00:00:00",
          "ID": "CVE-2017-14026",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Thermal Management Center",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to version 4.13"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Ice Qube"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Ice Qube Thermal Management Center versions prior to version 4.13, the web application does not properly authenticate users which may allow an attacker to gain access to sensitive information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER AUTHENTICATION CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-249-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-249-01"
            },
            {
              "name": "105303",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105303"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-14026",
    "datePublished": "2018-09-06T19:00:00.000Z",
    "dateReserved": "2017-08-30T00:00:00.000Z",
    "dateUpdated": "2024-09-16T23:55:57.237Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-14018 (GCVE-0-2017-14018)

Vulnerability from cvelistv5 – Published: 2017-12-05 23:00 – Updated: 2024-08-05 19:13
VLAI
Summary
An improper authentication issue was discovered in Johnson & Johnson Ethicon Endo-Surgery Generator Gen11, all versions released before November 29, 2017. The security authentication mechanism used between the Ethicon Endo-Surgery Generator Gen11 and single-patient use products can be bypassed, allowing for unauthorized devices to be connected to the generator, which could result in a loss of integrity or availability.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Ethicon Endo-Surgery Generator G11 Affected: Ethicon Endo-Surgery Generator G11
Date Public
2017-12-05 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:13:41.676Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "101978",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/101978"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-332-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Ethicon Endo-Surgery Generator G11",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Ethicon Endo-Surgery Generator G11"
            }
          ]
        }
      ],
      "datePublic": "2017-12-05T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An improper authentication issue was discovered in Johnson \u0026 Johnson Ethicon Endo-Surgery Generator Gen11, all versions released before November 29, 2017. The security authentication mechanism used between the Ethicon Endo-Surgery Generator Gen11 and single-patient use products can be bypassed, allowing for unauthorized devices to be connected to the generator, which could result in a loss of integrity or availability."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-06T10:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "101978",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/101978"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-332-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-14018",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Ethicon Endo-Surgery Generator G11",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Ethicon Endo-Surgery Generator G11"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An improper authentication issue was discovered in Johnson \u0026 Johnson Ethicon Endo-Surgery Generator Gen11, all versions released before November 29, 2017. The security authentication mechanism used between the Ethicon Endo-Surgery Generator Gen11 and single-patient use products can be bypassed, allowing for unauthorized devices to be connected to the generator, which could result in a loss of integrity or availability."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "101978",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/101978"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-332-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-332-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-14018",
    "datePublished": "2017-12-05T23:00:00.000Z",
    "dateReserved": "2017-08-30T00:00:00.000Z",
    "dateUpdated": "2024-08-05T19:13:41.676Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-14008 (GCVE-0-2017-14008)

Vulnerability from cvelistv5 – Published: 2018-03-20 16:00 – Updated: 2024-09-16 17:43
VLAI
Summary
GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
Severity
No CVSS data available.
CWE
  • CWE-287 - IMPROPER AUTHENTICATION CWE-287 The affected devices use default or hard-coded credentials.
Assigner
References
Impacted products
Date Public
2018-03-13 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:13:41.648Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "103400",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/103400"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "GE Centricity PACS RA1000",
          "vendor": "GE Healthcare",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        }
      ],
      "datePublic": "2018-03-13T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "IMPROPER AUTHENTICATION CWE-287 The affected devices use default or hard-coded credentials.",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-21T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "103400",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/103400"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-03-13T00:00:00",
          "ID": "CVE-2017-14008",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "GE Centricity PACS RA1000",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE Healthcare"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER AUTHENTICATION CWE-287 The affected devices use default or hard-coded credentials."
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "103400",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/103400"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-14008",
    "datePublished": "2018-03-20T16:00:00.000Z",
    "dateReserved": "2017-08-30T00:00:00.000Z",
    "dateUpdated": "2024-09-16T17:43:31.891Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-14006 (GCVE-0-2017-14006)

Vulnerability from cvelistv5 – Published: 2018-03-20 16:00 – Updated: 2024-09-16 23:20
VLAI
Summary
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
Severity
No CVSS data available.
CWE
  • CWE-287 - IMPROPER AUTHENTICATION CWE-287 The affected devices use default or hard-coded credentials.
Assigner
References
Impacted products
Vendor Product Version
GE Healthcare GE Xeleris Affected: 1.0,1.1,2.1,3.0,3.1
Create a notification for this product.
Date Public
2018-03-13 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:13:41.557Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "GE Xeleris",
          "vendor": "GE Healthcare",
          "versions": [
            {
              "status": "affected",
              "version": "1.0,1.1,2.1,3.0,3.1"
            }
          ]
        }
      ],
      "datePublic": "2018-03-13T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "IMPROPER AUTHENTICATION CWE-287 The affected devices use default or hard-coded credentials.",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-20T15:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-03-13T00:00:00",
          "ID": "CVE-2017-14006",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "GE Xeleris",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.0,1.1,2.1,3.0,3.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE Healthcare"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER AUTHENTICATION CWE-287 The affected devices use default or hard-coded credentials."
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-14006",
    "datePublished": "2018-03-20T16:00:00.000Z",
    "dateReserved": "2017-08-30T00:00:00.000Z",
    "dateUpdated": "2024-09-16T23:20:54.531Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-14004 (GCVE-0-2017-14004)

Vulnerability from cvelistv5 – Published: 2018-03-20 16:00 – Updated: 2024-09-16 17:27
VLAI
Summary
GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
Severity
No CVSS data available.
CWE
  • CWE-287 - IMPROPER AUTHENTICATION CWE-287 The affected devices use default or hard-coded credentials.
Assigner
References
Impacted products
Date Public
2018-03-13 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:13:41.677Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "GE GEMNet License server aka. (EchoServer)",
          "vendor": "GE Healthcare",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        }
      ],
      "datePublic": "2018-03-13T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "IMPROPER AUTHENTICATION CWE-287 The affected devices use default or hard-coded credentials.",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-20T15:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-03-13T00:00:00",
          "ID": "CVE-2017-14004",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "GE GEMNet License server aka. (EchoServer)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE Healthcare"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER AUTHENTICATION CWE-287 The affected devices use default or hard-coded credentials."
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-14004",
    "datePublished": "2018-03-20T16:00:00.000Z",
    "dateReserved": "2017-08-30T00:00:00.000Z",
    "dateUpdated": "2024-09-16T17:27:58.161Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-14002 (GCVE-0-2017-14002)

Vulnerability from cvelistv5 – Published: 2018-03-20 16:00 – Updated: 2024-09-17 02:52
VLAI
Summary
GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
Severity
No CVSS data available.
CWE
  • CWE-287 - IMPROPER AUTHENTICATION CWE-287 The affected devices use default or hard-coded credentials.
Assigner
References
Impacted products
Date Public
2018-03-13 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:13:41.691Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "103405",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/103405"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "GE Infinia",
          "vendor": "GE Healthcare",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        }
      ],
      "datePublic": "2018-03-13T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "IMPROPER AUTHENTICATION CWE-287 The affected devices use default or hard-coded credentials.",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-21T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "103405",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/103405"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-03-13T00:00:00",
          "ID": "CVE-2017-14002",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "GE Infinia",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE Healthcare"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER AUTHENTICATION CWE-287 The affected devices use default or hard-coded credentials."
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "103405",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/103405"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-14002",
    "datePublished": "2018-03-20T16:00:00.000Z",
    "dateReserved": "2017-08-30T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:52:52.873Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-14000 (GCVE-0-2017-14000)

Vulnerability from cvelistv5 – Published: 2017-10-04 07:00 – Updated: 2024-08-05 19:13
VLAI
Summary
An Improper Authentication issue was discovered in Ctek SkyRouter Series 4200 and 4400, all versions prior to V6.00.11. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the application without authenticating.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Ctek, Inc. SkyRouter Affected: Ctek, Inc. SkyRouter
Date Public
2017-10-04 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:13:41.648Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "100953",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/100953"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Ctek, Inc. SkyRouter",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Ctek, Inc. SkyRouter"
            }
          ]
        }
      ],
      "datePublic": "2017-10-04T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Authentication issue was discovered in Ctek SkyRouter Series 4200 and 4400, all versions prior to V6.00.11. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the application without authenticating."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-10-04T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "100953",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/100953"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-14000",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Ctek, Inc. SkyRouter",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Ctek, Inc. SkyRouter"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Authentication issue was discovered in Ctek SkyRouter Series 4200 and 4400, all versions prior to V6.00.11. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the application without authenticating."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "100953",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/100953"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-14000",
    "datePublished": "2017-10-04T07:00:00.000Z",
    "dateReserved": "2017-08-30T00:00:00.000Z",
    "dateUpdated": "2024-08-05T19:13:41.648Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-13995 (GCVE-0-2017-13995)

Vulnerability from cvelistv5 – Published: 2017-10-04 07:00 – Updated: 2024-08-05 19:13
VLAI
Summary
An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a iniNet Solutions GmbH SCADA Webserver Affected: iniNet Solutions GmbH SCADA Webserver
Date Public
2017-10-03 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:13:41.584Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "100951",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/100951"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "iniNet Solutions GmbH SCADA Webserver",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "iniNet Solutions GmbH SCADA Webserver"
            }
          ]
        }
      ],
      "datePublic": "2017-10-03T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-10-04T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "100951",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/100951"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-13995",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "iniNet Solutions GmbH SCADA Webserver",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "iniNet Solutions GmbH SCADA Webserver"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "100951",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/100951"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-264-04"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-13995",
    "datePublished": "2017-10-04T07:00:00.000Z",
    "dateReserved": "2017-08-30T00:00:00.000Z",
    "dateUpdated": "2024-08-05T19:13:41.584Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Architecture and Design

Strategy: Libraries or Frameworks

Use an authentication framework or library such as the OWASP ESAPI Authentication feature.

CAPEC-114: Authentication Abuse

An attacker obtains unauthorized access to an application, service or device either through knowledge of the inherent weaknesses of an authentication mechanism, or by exploiting a flaw in the authentication scheme's implementation. In such an attack an authentication mechanism is functioning but a carefully controlled sequence of events causes the mechanism to grant access to the attacker.

CAPEC-115: Authentication Bypass

An attacker gains access to application, service, or device with the privileges of an authorized or privileged user by evading or circumventing an authentication mechanism. The attacker is therefore able to access protected data without authentication ever having taken place.

CAPEC-151: Identity Spoofing

Identity Spoofing refers to the action of assuming (i.e., taking on) the identity of some other entity (human or non-human) and then using that identity to accomplish a goal. An adversary may craft messages that appear to come from a different principle or use stolen / spoofed authentication credentials.

CAPEC-194: Fake the Source of Data

An adversary takes advantage of improper authentication to provide data or services under a falsified identity. The purpose of using the falsified identity may be to prevent traceability of the provided data or to assume the rights granted to another individual. One of the simplest forms of this attack would be the creation of an email message with a modified "From" field in order to appear that the message was sent from someone other than the actual sender. The root of the attack (in this case the email system) fails to properly authenticate the source and this results in the reader incorrectly performing the instructed action. Results of the attack vary depending on the details of the attack, but common results include privilege escalation, obfuscation of other attacks, and data corruption/manipulation.

CAPEC-22: Exploiting Trust in Client

An attack of this type exploits vulnerabilities in client/server communication channel authentication and data integrity. It leverages the implicit trust a server places in the client, or more importantly, that which the server believes is the client. An attacker executes this type of attack by communicating directly with the server where the server believes it is communicating only with a valid client. There are numerous variations of this type of attack.

CAPEC-57: Utilizing REST's Trust in the System Resource to Obtain Sensitive Data

This attack utilizes a REST(REpresentational State Transfer)-style applications' trust in the system resources and environment to obtain sensitive data once SSL is terminated.

CAPEC-593: Session Hijacking

This type of attack involves an adversary that exploits weaknesses in an application's use of sessions in performing authentication. The adversary is able to steal or manipulate an active session and use it to gain unathorized access to the application.

CAPEC-633: Token Impersonation

An adversary exploits a weakness in authentication to create an access token (or equivalent) that impersonates a different entity, and then associates a process/thread to that that impersonated token. This action causes a downstream user to make a decision or take action that is based on the assumed identity, and not the response that blocks the adversary.

CAPEC-650: Upload a Web Shell to a Web Server

By exploiting insufficient permissions, it is possible to upload a web shell to a web server in such a way that it can be executed remotely. This shell can have various capabilities, thereby acting as a "gateway" to the underlying web server. The shell might execute at the higher permission level of the web server, providing the ability the execute malicious code at elevated levels.

CAPEC-94: Adversary in the Middle (AiTM)

An adversary targets the communication between two components (typically client and server), in order to alter or obtain data from transactions. A general approach entails the adversary placing themself within the communication channel between the two components.