CWE-250
AllowedExecution with Unnecessary Privileges
Abstraction: Base · Status: Draft
The product performs an operation at a privilege level that is higher than the minimum level required, which creates new weaknesses or amplifies the consequences of other weaknesses.
575 vulnerabilities reference this CWE, most recent first.
CVE-2024-47903 (GCVE-0-2024-47903)
Vulnerability from cvelistv5 – Published: 2024-10-23 14:21 – Updated: 2024-10-23 18:02- CWE-250 - Execution with Unnecessary Privileges
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | InterMesh 7177 Hybrid 2.0 Subscriber |
Affected:
0 , < V8.2.12
(custom)
|
|
| Siemens | InterMesh 7707 Fire Subscriber |
Affected:
0 , < V7.2.12
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-47903",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T18:01:58.898600Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T18:02:13.310Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "InterMesh 7177 Hybrid 2.0 Subscriber",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "InterMesh 7707 Fire Subscriber",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.2.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions \u003c V8.2.12), InterMesh 7707 Fire Subscriber (All versions \u003c V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices allows to write arbitrary files to the web server\u0027s DocumentRoot directory."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:L/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T14:21:21.774Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-333468.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-47903",
"datePublished": "2024-10-23T14:21:21.774Z",
"dateReserved": "2024-10-04T16:15:00.392Z",
"dateUpdated": "2024-10-23T18:02:13.310Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-47120 (GCVE-0-2024-47120)
Vulnerability from cvelistv5 – Published: 2025-09-10 20:04 – Updated: 2026-02-26 17:48- CWE-250 - Execution with Unnecessary Privileges
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7244514 | vendor-advisorypatch |
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Security Verify Information Queue |
Affected:
10.0.5
Affected: 10.0.6 Affected: 10.0.7 Affected: 10.0.8 cpe:2.3:a:ibm:security_verify_information_queue:10.0.5:*:*:*:*:*:*:* cpe:2.3:a:ibm:security_verify_information_queue:10.0.6:*:*:*:*:*:*:* cpe:2.3:a:ibm:security_verify_information_queue:10.0.7:*:*:*:*:*:*:* cpe:2.3:a:ibm:security_verify_information_queue:10.0.8:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-47120",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-13T03:55:37.680342Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-26T17:48:41.624Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:ibm:security_verify_information_queue:10.0.5:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:security_verify_information_queue:10.0.6:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:security_verify_information_queue:10.0.7:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:security_verify_information_queue:10.0.8:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "Security Verify Information Queue",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "10.0.5"
},
{
"status": "affected",
"version": "10.0.6"
},
{
"status": "affected",
"version": "10.0.7"
},
{
"status": "affected",
"version": "10.0.8"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "IBM Security Verify Information Queue 10.0.5, 10.0.6, 10.0.7, and 10.0.8 could allow a privileged user to escalate their privileges and attack surface on the host due to the containers running with unnecessary privileges."
}
],
"value": "IBM Security Verify Information Queue 10.0.5, 10.0.6, 10.0.7, and 10.0.8 could allow a privileged user to escalate their privileges and attack surface on the host due to the containers running with unnecessary privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250 Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-10T20:04:19.307Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7244514"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003cstrong\u003eIBM encourages customers to update their systems promptly.\u003c/strong\u003e\u003c/p\u003e\u003cp\u003eDownload and install the latest ISIQ images for \u003cstrong\u003ev10.0.11\u003c/strong\u003e\u0026nbsp;from \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ibm.com/support/pages/ibm-security-information-queue-starter-kit\"\u003eIBM Security Information Queue Starter Kit\u003c/a\u003e\u0026nbsp;page.\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "IBM encourages customers to update their systems promptly.\n\nDownload and install the latest ISIQ images for v10.0.11\u00a0from IBM Security Information Queue Starter Kit https://www.ibm.com/support/pages/ibm-security-information-queue-starter-kit \u00a0page."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "IBM Security Verify Information Queue code execution",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2024-47120",
"datePublished": "2025-09-10T20:04:19.307Z",
"dateReserved": "2024-09-18T19:27:02.822Z",
"dateUpdated": "2026-02-26T17:48:41.624Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-45034 (GCVE-0-2024-45034)
Vulnerability from cvelistv5 – Published: 2024-09-07 07:45 – Updated: 2024-09-09 13:55- CWE-250 - Execution with Unnecessary Privileges
| Vendor | Product | Version | |
|---|---|---|---|
| Apache Software Foundation | Apache Airflow |
Affected:
0 , < 2.10.1
(semver)
|
|
| apache | airflow |
Affected:
0 , < 2.10.1
(semver)
cpe:2.3:a:apache:airflow:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-09-07T08:03:12.429Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://www.openwall.com/lists/oss-security/2024/09/06/3"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:apache:airflow:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "airflow",
"vendor": "apache",
"versions": [
{
"lessThan": "2.10.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-45034",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-09T13:50:48.026862Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-09T13:55:13.683Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://pypi.python.org",
"defaultStatus": "unaffected",
"packageName": "apache-airflow",
"product": "Apache Airflow",
"vendor": "Apache Software Foundation",
"versions": [
{
"lessThan": "2.10.1",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Seokchan Yoon: https://github.com/ch4n3-yoon"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Amogh Desai"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Apache Airflow versions before 2.10.1 have a vulnerability that allows\u0026nbsp;DAG authors to add local settings to the DAG folder and get it executed by the scheduler, where the scheduler is not supposed to execute code submitted by the DAG author. \u003cbr\u003eUsers are advised to upgrade to version 2.10.1 or later, which has fixed the vulnerability."
}
],
"value": "Apache Airflow versions before 2.10.1 have a vulnerability that allows\u00a0DAG authors to add local settings to the DAG folder and get it executed by the scheduler, where the scheduler is not supposed to execute code submitted by the DAG author. \nUsers are advised to upgrade to version 2.10.1 or later, which has fixed the vulnerability."
}
],
"metrics": [
{
"other": {
"content": {
"text": "important"
},
"type": "Textual description of severity"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-07T07:45:27.654Z",
"orgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
"shortName": "apache"
},
"references": [
{
"tags": [
"patch"
],
"url": "https://github.com/apache/airflow/pull/41672"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://lists.apache.org/thread/b4fcw33vh60yfg9990n5vmc7sy2dcgjx"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Apache Airflow: Authenticated DAG authors could execute code on scheduler nodes",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
"assignerShortName": "apache",
"cveId": "CVE-2024-45034",
"datePublished": "2024-09-07T07:45:27.654Z",
"dateReserved": "2024-08-21T12:41:18.078Z",
"dateUpdated": "2024-09-09T13:55:13.683Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-43655 (GCVE-0-2024-43655)
Vulnerability from cvelistv5 – Published: 2025-01-09 07:56 – Updated: 2025-03-11 13:07| URL | Tags |
|---|---|
| https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory |
| https://csirt.divd.nl/CVE-2024-43655/ | third-party-advisory |
| https://iocharger.com | product |
| Vendor | Product | Version | |
|---|---|---|---|
| Iocharger | Iocharger firmware for AC models |
Affected:
0 , < 24120701
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-43655",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T15:11:43.639526Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T15:12:19.472Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iocharger firmware for AC models",
"vendor": "Iocharger",
"versions": [
{
"lessThan": "24120701",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Wilco van Beijnum"
},
{
"lang": "en",
"type": "analyst",
"value": "Harm van den Brink (DIVD)"
},
{
"lang": "en",
"type": "analyst",
"value": "Frank Breedijk (DIVD)"
}
],
"datePublic": "2025-01-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\u003cbr\u003e\u003cbr\u003eThis issue affects Iocharger firmware for AC model chargers before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).\u003cbr\u003e"
}
],
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\n\nThis issue affects Iocharger firmware for AC model chargers before version 24120701.\n\nLikelihood: Moderate \u2013 The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"Safety": "PRESENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"description": "OWASP-A03: Injection",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:07:19.985Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2024-00035/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2024-43655/"
},
{
"tags": [
"product"
],
"url": "https://iocharger.com"
}
],
"source": {
"advisory": "DIVD-2024-00035",
"discovery": "EXTERNAL"
},
"title": "Any authenticated users can execute OS commands as root using the \u003credacted\u003e.sh CGI script.",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2024-43655",
"datePublished": "2025-01-09T07:56:45.279Z",
"dateReserved": "2024-08-14T09:27:41.768Z",
"dateUpdated": "2025-03-11T13:07:19.985Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-43654 (GCVE-0-2024-43654)
Vulnerability from cvelistv5 – Published: 2025-01-09 07:56 – Updated: 2025-03-11 13:07| URL | Tags |
|---|---|
| https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory |
| https://csirt.divd.nl/CVE-2024-43654/ | third-party-advisory |
| https://iocharger.com | product |
| Vendor | Product | Version | |
|---|---|---|---|
| Iocharger | Iocharger firmware for AC models |
Affected:
0 , < 25010801
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-43654",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T14:32:43.409061Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T14:33:30.319Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iocharger firmware for AC models",
"vendor": "Iocharger",
"versions": [
{
"lessThan": "25010801",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Wilco van Beijnum"
},
{
"lang": "en",
"type": "analyst",
"value": "Harm van den Brink (DIVD)"
},
{
"lang": "en",
"type": "analyst",
"value": "Frank Breedijk (DIVD)"
}
],
"datePublic": "2025-01-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Iocharger firmware for AC models allows OS Command Injection as root\u003cbr\u003eThis issue affects all Iocharger AC EV charger models on a firmware version before 25010801.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The \u0026lt;redacted\u0026gt; binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a crafted HTTP request.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\u003cbr\u003efiles and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).\u003cbr\u003e"
}
],
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Iocharger firmware for AC models allows OS Command Injection as root\nThis issue affects all Iocharger AC EV charger models on a firmware version before 25010801.\n\nLikelihood: Moderate \u2013 The \u003credacted\u003e binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\nfiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"Safety": "PRESENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"description": "OWASP-A03: Injection",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:07:09.158Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2024-00035/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2024-43654/"
},
{
"tags": [
"product"
],
"url": "https://iocharger.com"
}
],
"source": {
"advisory": "DIVD-2024-00035",
"discovery": "EXTERNAL"
},
"title": "Authenticated command injection in the \u003credacted\u003e action leads to full remote code execution as root on the charging station",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2024-43654",
"datePublished": "2025-01-09T07:56:47.131Z",
"dateReserved": "2024-08-14T09:27:41.768Z",
"dateUpdated": "2025-03-11T13:07:09.158Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-43653 (GCVE-0-2024-43653)
Vulnerability from cvelistv5 – Published: 2025-01-09 07:56 – Updated: 2025-03-11 13:07| URL | Tags |
|---|---|
| https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory |
| https://csirt.divd.nl/CVE-2024-43653/ | third-party-advisory |
| https://iocharger.com | product |
| Vendor | Product | Version | |
|---|---|---|---|
| Iocharger | Iocharger firmware for AC models |
Affected:
0 , < 24120701
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-43653",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T14:39:24.235683Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T14:40:21.083Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iocharger firmware for AC models",
"vendor": "Iocharger",
"versions": [
{
"lessThan": "24120701",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Wilco van Beijnum"
},
{
"lang": "en",
"type": "analyst",
"value": "Harm van den Brink (DIVD)"
},
{
"lang": "en",
"type": "analyst",
"value": "Frank Breedijk (DIVD)"
}
],
"datePublic": "2025-01-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability\u0026nbsp; allows OS Command Injection as root\u003cbr\u003eThis issue affects Iocharger firmware for AC model chargers before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The \u0026lt;redacted\u0026gt; binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a crafted HTTP request.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\u003cbr\u003efiles and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).\u003cbr\u003e"
}
],
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability\u00a0 allows OS Command Injection as root\nThis issue affects Iocharger firmware for AC model chargers before version 24120701.\n\nLikelihood: Moderate \u2013 The \u003credacted\u003e binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\nfiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"Safety": "PRESENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"description": "OWASP-A03: Injection",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:07:21.123Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2024-00035/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2024-43653/"
},
{
"tags": [
"product"
],
"url": "https://iocharger.com"
}
],
"source": {
"advisory": "DIVD-2024-00035",
"discovery": "EXTERNAL"
},
"title": "Authenticated command injection in the \u003credacted\u003e action leads to full remote code execution as root on the charging station",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2024-43653",
"datePublished": "2025-01-09T07:56:46.647Z",
"dateReserved": "2024-08-14T09:27:41.767Z",
"dateUpdated": "2025-03-11T13:07:21.123Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-43652 (GCVE-0-2024-43652)
Vulnerability from cvelistv5 – Published: 2025-01-09 07:56 – Updated: 2025-03-11 13:07| URL | Tags |
|---|---|
| https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory |
| https://csirt.divd.nl/CVE-2024-43652/ | third-party-advisory |
| https://iocharger.com | product |
| Vendor | Product | Version | |
|---|---|---|---|
| Iocharger | Iocharger firmware for AC chargers |
Affected:
0 , < 24120701
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-43652",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T14:42:07.955181Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T14:43:04.986Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iocharger firmware for AC chargers",
"vendor": "Iocharger",
"versions": [
{
"lessThan": "24120701",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Wilco van Beijnum"
},
{
"lang": "en",
"type": "analyst",
"value": "Harm van den Brink (DIVD)"
},
{
"lang": "en",
"type": "analyst",
"value": "Frank Breedijk (DIVD)"
}
],
"datePublic": "2025-01-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\u003cbr\u003eThis issue affects Iocharger firmware for AC model chargers before version 24120701\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The \u0026lt;redacted\u0026gt; binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a crafted HTTP request.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\u003cbr\u003efiles and services.\u003cbr\u003e"
}
],
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\nThis issue affects Iocharger firmware for AC model chargers before version 24120701\n\nLikelihood: Moderate \u2013 The \u003credacted\u003e binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\nfiles and services."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "USER",
"Safety": "PRESENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y/R:U/V:D/RE:M",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"description": "OWASP-A03: Injection",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:07:18.824Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2024-00035/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2024-43652/"
},
{
"tags": [
"product"
],
"url": "https://iocharger.com"
}
],
"source": {
"advisory": "DIVD-2024-00035",
"discovery": "EXTERNAL"
},
"title": "Authenticated command injection in the \u003credacted\u003e action leads to full remote code execution as root on the charging station",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2024-43652",
"datePublished": "2025-01-09T07:56:46.379Z",
"dateReserved": "2024-08-14T09:27:41.767Z",
"dateUpdated": "2025-03-11T13:07:18.824Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-43651 (GCVE-0-2024-43651)
Vulnerability from cvelistv5 – Published: 2025-01-09 07:56 – Updated: 2025-03-11 13:07| URL | Tags |
|---|---|
| https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory |
| https://csirt.divd.nl/CVE-2024-43651/ | third-party-advisory |
| https://iocharger.com | product |
| Vendor | Product | Version | |
|---|---|---|---|
| Iocharger | Iocharger firmware for AC models |
Affected:
0 , < 24120701
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-43651",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T15:20:15.887605Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T15:21:03.613Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iocharger firmware for AC models",
"vendor": "Iocharger",
"versions": [
{
"lessThan": "24120701",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Wilco van Beijnum"
},
{
"lang": "en",
"type": "analyst",
"value": "Harm van den Brink (DIVD)"
},
{
"lang": "en",
"type": "analyst",
"value": "Frank Breedijk (DIVD)"
}
],
"datePublic": "2025-01-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\u003cbr\u003eThis issue affects Iocharger firmware for AC models before version 241207101\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The \u0026lt;redacted\u0026gt; binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a crafted HTTP request.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification:\u0026nbsp;Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially \"pivot\" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y)."
}
],
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability allows OS Command Injection as root\nThis issue affects Iocharger firmware for AC models before version 241207101\n\nLikelihood: Moderate \u2013 The \u003credacted\u003e binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\n\nCVSS clarification:\u00a0Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially \"pivot\" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y)."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"Safety": "PRESENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"description": "OWASP-A03: Injection",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:07:06.826Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2024-00035/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2024-43651/"
},
{
"tags": [
"product"
],
"url": "https://iocharger.com"
}
],
"source": {
"advisory": "DIVD-2024-00035",
"discovery": "EXTERNAL"
},
"title": "Authenticated command injection in the \u003credacted\u003e action leads to full remote code execution as root on the charging station",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2024-43651",
"datePublished": "2025-01-09T07:56:47.394Z",
"dateReserved": "2024-08-14T09:27:41.767Z",
"dateUpdated": "2025-03-11T13:07:06.826Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-43650 (GCVE-0-2024-43650)
Vulnerability from cvelistv5 – Published: 2025-01-09 07:56 – Updated: 2025-03-11 13:07| URL | Tags |
|---|---|
| https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory |
| https://csirt.divd.nl/CVE-2024-43650/ | third-party-advisory |
| https://iocharger.com | product |
| Vendor | Product | Version | |
|---|---|---|---|
| Iocharger | Iocharger firmware for AC models |
Affected:
0 , < 24120701
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-43650",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T15:09:01.310561Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T15:09:57.625Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iocharger firmware for AC models",
"vendor": "Iocharger",
"versions": [
{
"lessThan": "24120701",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Wilco van Beijnum"
},
{
"lang": "en",
"type": "analyst",
"value": "Harm van den Brink (DIVD)"
},
{
"lang": "en",
"type": "analyst",
"value": "Frank Breedijk (DIVD)"
}
],
"datePublic": "2025-01-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Iocharger firmware for AC models allows OS Command Injection as root\u003cbr\u003e\u003cbr\u003eThis issue affects\u0026nbsp; firmware versions before 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The \u0026lt;redacted\u0026gt; binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a crafted HTTP request.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\u003cbr\u003efiles and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to \"pivot\" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y)."
}
],
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in Iocharger firmware for AC models allows OS Command Injection as root\n\nThis issue affects\u00a0 firmware versions before 24120701.\n\nLikelihood: Moderate \u2013 The \u003credacted\u003e binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\nfiles and services.\n\nCVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to \"pivot\" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y)."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"Safety": "PRESENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"description": "OWASP-A03: Injection",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:07:12.866Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2024-00035/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2024-43650/"
},
{
"tags": [
"product"
],
"url": "https://iocharger.com"
}
],
"source": {
"advisory": "DIVD-2024-00035",
"discovery": "EXTERNAL"
},
"title": "Authenticated command injection in the \u003credacted\u003e action leads to full remote code execution as root on the charging station",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2024-43650",
"datePublished": "2025-01-09T07:56:45.504Z",
"dateReserved": "2024-08-14T09:27:41.767Z",
"dateUpdated": "2025-03-11T13:07:12.866Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-43649 (GCVE-0-2024-43649)
Vulnerability from cvelistv5 – Published: 2025-01-09 07:56 – Updated: 2025-03-11 13:07| URL | Tags |
|---|---|
| https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory |
| https://csirt.divd.nl/CVE-2024-43649/ | third-party-advisory |
| https://iocharger.com | product |
| Vendor | Product | Version | |
|---|---|---|---|
| Iocharger | Iocharger firmware for AC models |
Affected:
0 , < 24120701
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-43649",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T14:35:10.473442Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T14:36:23.194Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iocharger firmware for AC models",
"vendor": "Iocharger",
"versions": [
{
"lessThan": "24120701",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Wilco van Beijnum"
},
{
"lang": "en",
"type": "analyst",
"value": "Harm van den Brink (DIVD)"
},
{
"lang": "en",
"type": "analyst",
"value": "Frank Breedijk (DIVD)"
}
],
"datePublic": "2025-01-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Authenticated command injection in the filename of a \u0026lt;redacted\u0026gt;.exe request leads to remote code execution as the root user.\u003cbr\u003e\u003cbr\u003eThis issue affects Iocharger firmware for AC models before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all \u0026lt;redacted\u0026gt; fields. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a payload.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification:\u0026nbsp;This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to \"pivot\" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y)."
}
],
"value": "Authenticated command injection in the filename of a \u003credacted\u003e.exe request leads to remote code execution as the root user.\n\nThis issue affects Iocharger firmware for AC models before version 24120701.\n\nLikelihood: Moderate \u2013 This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all \u003credacted\u003e fields. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a payload.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.\n\nCVSS clarification:\u00a0This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to \"pivot\" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y)."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"Safety": "PRESENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"description": "OWASP-A03: Injection",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:07:05.672Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2024-00035/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2024-43649/"
},
{
"tags": [
"product"
],
"url": "https://iocharger.com"
}
],
"source": {
"advisory": "DIVD-2024-00035",
"discovery": "EXTERNAL"
},
"title": "Authenticated command injection via \u003credacted\u003e.exe \u003credacted\u003e parameter",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2024-43649",
"datePublished": "2025-01-09T07:56:46.982Z",
"dateReserved": "2024-08-14T09:27:41.767Z",
"dateUpdated": "2025-03-11T13:07:05.672Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation MIT-17
Strategy: Environment Hardening
Run your code using the lowest privileges that are required to accomplish the necessary tasks [REF-76]. If possible, create isolated accounts with limited privileges that are only used for a single task. That way, a successful attack will not immediately give the attacker access to the rest of the software or its environment. For example, database applications rarely need to run as the database administrator, especially in day-to-day operations.
Mitigation MIT-18
Strategy: Separation of Privilege
Identify the functionality that requires additional privileges, such as access to privileged operating system resources. Wrap and centralize this functionality if possible, and isolate the privileged code as much as possible from other code [REF-76]. Raise privileges as late as possible, and drop them as soon as possible to avoid CWE-271. Avoid weaknesses such as CWE-288 and CWE-420 by protecting all possible communication channels that could interact with the privileged code, such as a secondary socket that is only intended to be accessed by administrators.
Mitigation MIT-18
Strategy: Attack Surface Reduction
Identify the functionality that requires additional privileges, such as access to privileged operating system resources. Wrap and centralize this functionality if possible, and isolate the privileged code as much as possible from other code [REF-76]. Raise privileges as late as possible, and drop them as soon as possible to avoid CWE-271. Avoid weaknesses such as CWE-288 and CWE-420 by protecting all possible communication channels that could interact with the privileged code, such as a secondary socket that is only intended to be accessed by administrators.
Mitigation
Perform extensive input validation for any privileged code that must be exposed to the user and reject anything that does not fit your strict requirements.
Mitigation MIT-19
When dropping privileges, ensure that they have been dropped successfully to avoid CWE-273. As protection mechanisms in the environment get stronger, privilege-dropping calls may fail even if it seems like they would always succeed.
Mitigation
If circumstances force you to run with extra privileges, then determine the minimum access level necessary. First identify the different permissions that the software and its users will need to perform their actions, such as file read and write permissions, network socket permissions, and so forth. Then explicitly allow those actions while denying all else [REF-76]. Perform extensive input validation and canonicalization to minimize the chances of introducing a separate vulnerability. This mitigation is much more prone to error than dropping the privileges in the first place.
Mitigation MIT-37
Strategy: Environment Hardening
Ensure that the software runs properly under the United States Government Configuration Baseline (USGCB) [REF-199] or an equivalent hardening configuration guide, which many organizations use to limit the attack surface and potential risk of deployed software.
CAPEC-104: Cross Zone Scripting
An attacker is able to cause a victim to load content into their web-browser that bypasses security zone controls and gain access to increased privileges to execute scripting code or other web objects such as unsigned ActiveX controls or applets. This is a privilege elevation attack targeted at zone-based web-browser security.
CAPEC-470: Expanding Control over the Operating System from the Database
An attacker is able to leverage access gained to the database to read / write data to the file system, compromise the operating system, create a tunnel for accessing the host machine, and use this access to potentially attack other machines on the same network as the database machine. Traditionally SQL injections attacks are viewed as a way to gain unauthorized read access to the data stored in the database, modify the data in the database, delete the data, etc. However, almost every data base management system (DBMS) system includes facilities that if compromised allow an attacker complete access to the file system, operating system, and full access to the host running the database. The attacker can then use this privileged access to launch subsequent attacks. These facilities include dropping into a command shell, creating user defined functions that can call system level libraries present on the host machine, stored procedures, etc.
CAPEC-69: Target Programs with Elevated Privileges
This attack targets programs running with elevated privileges. The adversary tries to leverage a vulnerability in the running program and get arbitrary code to execute with elevated privileges.