var-201812-0346
Vulnerability from variot
A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial-of-Service condition impacting the availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known. SIMATIC S7-1200 and SIMATIC S7-1500 Contains a resource exhaustion vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Siemens SIMATIC S7-1200 and SIMATIC S7-1500 are programmable logic controllers (PLCs) from Siemens AG in small and medium-sized automation systems. Siemens SIMATIC S7 is prone to a denial-of-service vulnerability. Remote attackers may exploit this issue to cause denial-of-service conditions, denying service to legitimate users
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201812-0346", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic s7-1500", "scope": "lt", "trust": 2.4, "vendor": "siemens", "version": "2.6" }, { "model": "simatic s7-1200", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1.8.3" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1.7" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2.5" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1.6" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1.5.0" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-1500", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "2.6" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1200", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500", "version": "*" } ], "sources": [ { "db": "IVD", "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25436" }, { "db": "BID", "id": "105928" }, { "db": "JVNDB", "id": "JVNDB-2018-014528" }, { "db": "NVD", "id": "CVE-2018-13815" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:simatic_s7-1200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-014528" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Younes Dragoni of Nozomi Networks", "sources": [ { "db": "BID", "id": "105928" } ], "trust": 0.3 }, "cve": "CVE-2018-13815", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2018-13815", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2018-25436", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-123912", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2018-13815", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-13815", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-13815", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2018-25436", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201811-486", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-123912", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25436" }, { "db": "VULHUB", "id": "VHN-123912" }, { "db": "JVNDB", "id": "JVNDB-2018-014528" }, { "db": "CNNVD", "id": "CNNVD-201811-486" }, { "db": "NVD", "id": "CVE-2018-13815" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions \u003c V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial-of-Service condition impacting the availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known. SIMATIC S7-1200 and SIMATIC S7-1500 Contains a resource exhaustion vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Siemens SIMATIC S7-1200 and SIMATIC S7-1500 are programmable logic controllers (PLCs) from Siemens AG in small and medium-sized automation systems. Siemens SIMATIC S7 is prone to a denial-of-service vulnerability. \nRemote attackers may exploit this issue to cause denial-of-service conditions, denying service to legitimate users", "sources": [ { "db": "NVD", "id": "CVE-2018-13815" }, { "db": "JVNDB", "id": "JVNDB-2018-014528" }, { "db": "CNVD", "id": "CNVD-2018-25436" }, { "db": "BID", "id": "105928" }, { "db": "IVD", "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1" }, { "db": "VULHUB", "id": "VHN-123912" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-13815", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-18-317-05", "trust": 2.3 }, { "db": "BID", "id": "105928", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-584286", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-201811-486", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2018-25436", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2018-014528", "trust": 0.8 }, { "db": "IVD", "id": "7D80FC81-463F-11E9-8E8E-000C29342CB1", "trust": 0.2 }, { "db": "SEEBUG", "id": "SSVID-98855", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-123912", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25436" }, { "db": "VULHUB", "id": "VHN-123912" }, { "db": "BID", "id": "105928" }, { "db": "JVNDB", "id": "JVNDB-2018-014528" }, { "db": "CNNVD", "id": "CNNVD-201811-486" }, { "db": "NVD", "id": "CVE-2018-13815" } ] }, "id": "VAR-201812-0346", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25436" }, { "db": "VULHUB", "id": "VHN-123912" } ], "trust": 1.567001695 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 }, { "category": [ "ICS" ], "sub_category": null, "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25436" } ] }, "last_update_date": "2024-11-23T22:37:57.648000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-584286", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-584286.pdf" }, { "title": "Patch for SiemensSIMATICS7-1200 and SIMATICS7-1500 denial of service vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/147357" }, { "title": "Siemens SIMATIC S7-1200 and SIMATIC S7-1500 Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=86887" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-25436" }, { "db": "JVNDB", "id": "JVNDB-2018-014528" }, { "db": "CNNVD", "id": "CNNVD-201811-486" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.9 }, { "problemtype": "CWE-410", "trust": 1.0 } ], "sources": [ { "db": "VULHUB", "id": "VHN-123912" }, { "db": "JVNDB", "id": "JVNDB-2018-014528" }, { "db": "NVD", "id": "CVE-2018-13815" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-317-05" }, { "trust": 1.7, "url": "http://www.securityfocus.com/bid/105928" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-584286.pdf" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-13815" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-13815" }, { "trust": 0.3, "url": "http://www.siemens.com/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-25436" }, { "db": "VULHUB", "id": "VHN-123912" }, { "db": "BID", "id": "105928" }, { "db": "JVNDB", "id": "JVNDB-2018-014528" }, { "db": "CNNVD", "id": "CNNVD-201811-486" }, { "db": "NVD", "id": "CVE-2018-13815" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25436" }, { "db": "VULHUB", "id": "VHN-123912" }, { "db": "BID", "id": "105928" }, { "db": "JVNDB", "id": "JVNDB-2018-014528" }, { "db": "CNNVD", "id": "CNNVD-201811-486" }, { "db": "NVD", "id": "CVE-2018-13815" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-12-14T00:00:00", "db": "IVD", "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1" }, { "date": "2018-12-14T00:00:00", "db": "CNVD", "id": "CNVD-2018-25436" }, { "date": "2018-12-13T00:00:00", "db": "VULHUB", "id": "VHN-123912" }, { "date": "2018-11-13T00:00:00", "db": "BID", "id": "105928" }, { "date": "2019-03-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-014528" }, { "date": "2018-11-15T00:00:00", "db": "CNNVD", "id": "CNNVD-201811-486" }, { "date": "2018-12-13T16:29:00.383000", "db": "NVD", "id": "CVE-2018-13815" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-12-14T00:00:00", "db": "CNVD", "id": "CNVD-2018-25436" }, { "date": "2019-10-09T00:00:00", "db": "VULHUB", "id": "VHN-123912" }, { "date": "2018-11-13T00:00:00", "db": "BID", "id": "105928" }, { "date": "2019-03-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-014528" }, { "date": "2019-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201811-486" }, { "date": "2024-11-21T03:48:07.740000", "db": "NVD", "id": "CVE-2018-13815" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201811-486" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "SIMATIC S7-1200 and SIMATIC S7-1500 Vulnerable to resource exhaustion", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-014528" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Resource management error", "sources": [ { "db": "IVD", "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1" }, { "db": "CNNVD", "id": "CNNVD-201811-486" } ], "trust": 0.8 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.