SEVD-2025-224-02

Vulnerability from csaf_se - Published: 2025-08-12 04:00 - Updated: 2025-11-11 08:00
Summary
EcoStruxure™ Power Monitoring Expert Software & EcoStruxure™ Power Operation (EPO) and EcoStruxure™ Power SCADA Operation (PSO)

Notes

General Security Recommendations
We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.
For More Information
This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp
LEGAL DISCLAIMER
THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION
About Schneider Electric
Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com
Overview
Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure™ Power Monitoring Expert (PME) and EcoStruxure™ Power Operation (EPO) and EcoStruxure™ Power SCADA Operation (PSO) products. EcoStruxure™ Power Monitoring Expert (PME) is an on-premises software used to help power critical and energy-intensive facilities maximize uptime and operational efficiency. Note: There are some instances of PME being deployed in a Managed Service model. EcoStruxure™ Power Operation (EPO) and EcoStruxure™ Power SCADA Operation (PSO) are on-premises software offers that provides a single platform to monitor and control medium and lower power systems. Failure to apply the remediation and/or mitigations provided below may risk deserialization of untrusted data, server-side request forgery and/or path traversal that could result in remote code execution, and/or unauthorized access to sensitive data.
The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 ([CVSS v4.0](https://www.first.org/cvss/calculator/4.0)). CVSS v3.1 will be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without incorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as the presence of mitigations in that environment. Environmental metrics may refine the relative severity posed by the vulnerabilities described in this document within a customer's environment.
Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric's [Customer Care Center](https://www.se.com/us/en/work/support/contacts.jsp) if you need assistance removing a patch.
NOTE: EcoStruxure™ Power Operation 2022 with Advanced Reporting AND EcoStruxure™ Power Operation 2024 with Advanced Reporting utilizes EcoStruxure™ Power Monitoring Expert. You must update EcoStruxure™ Power Monitoring Expert separately from EcoStruxure™ Power Operation and apply the appropriate update for Power Monitoring Expert as described above.

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Public",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "We strongly recommend the following industry cybersecurity best practices.\n\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\n\nFor more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.",
        "title": "General Security Recommendations"
      },
      {
        "category": "general",
        "text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\n\nFor further information related to cybersecurity in Schneider Electric\u0027s products, visit the company\u0027s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
        "title": "For More Information"
      },
      {
        "category": "legal_disclaimer",
        "text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND.  SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
        "title": "LEGAL DISCLAIMER"
      },
      {
        "category": "general",
        "text": "Schneider\u0027s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and\r\nsustainability for all. We call this Life Is On.\n\nOur mission is to be the trusted partner in Sustainability and Efficiency.\n\nWe are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart\r\nindustries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep\r\ndomain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,\r\nsoftware and services, delivering digital twins to enable profitable growth for our customers.\n\nWe are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries\r\nto ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our\r\nmeaningful purpose of a sustainable future for all. \n\n www.se.com",
        "title": "About Schneider Electric"
      },
      {
        "category": "summary",
        "text": "Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure\u2122 Power Monitoring Expert (PME) and\nEcoStruxure\u2122 Power Operation (EPO) and EcoStruxure\u2122 Power SCADA Operation (PSO) products.\r\nEcoStruxure\u2122 Power Monitoring Expert (PME) is an on-premises software used to help power critical and\nenergy-intensive facilities maximize uptime and operational efficiency. Note: There are some instances of PME\nbeing deployed in a Managed Service model.\r\nEcoStruxure\u2122 Power Operation (EPO) and EcoStruxure\u2122 Power SCADA Operation (PSO) are on-premises\nsoftware offers that provides a single platform to monitor and control medium and lower power systems.\r\nFailure to apply the remediation and/or mitigations provided below may risk deserialization of untrusted data,\nserver-side request forgery and/or path traversal that could result in remote code execution, and/or\runauthorized access to sensitive data.",
        "title": "Overview"
      },
      {
        "category": "other",
        "text": "The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 ([CVSS v4.0](https://www.first.org/cvss/calculator/4.0)). CVSS v3.1 \nwill be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without \nincorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as \nthe presence of mitigations in that environment. Environmental metrics may refine the relative severity posed by the vulnerabilities described in this document within a customer\u0027s environment."
      },
      {
        "category": "other",
        "text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u0027s [Customer Care Center](https://www.se.com/us/en/work/support/contacts.jsp) if you need assistance removing a patch. "
      },
      {
        "category": "details",
        "text": "NOTE: EcoStruxure\u2122 Power Operation 2022 with Advanced Reporting AND EcoStruxure\u2122 Power Operation 2024 with Advanced Reporting utilizes EcoStruxure\u2122 Power Monitoring Expert. You must update EcoStruxure\u2122 Power Monitoring Expert separately from EcoStruxure\u2122 Power Operation and apply the appropriate update for Power Monitoring Expert as described above."
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "cpcert@se.com",
      "name": "Schneider Electric CPCERT",
      "namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
    },
    "references": [
      {
        "category": "self",
        "summary": "EcoStruxure\u2122 Power Monitoring Expert Software \u0026 EcoStruxure\u2122 Power Operation (EPO) and EcoStruxure\u2122 Power SCADA Operation (PSO) - SEVD-2025-224-02 PDF Version",
        "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-224-02.pdf"
      },
      {
        "category": "self",
        "summary": "EcoStruxure\u2122 Power Monitoring Expert Software \u0026 EcoStruxure\u2122 Power Operation (EPO) and EcoStruxure\u2122 Power SCADA Operation (PSO) - SEVD-2025-224-02 CSAF Version",
        "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-224-02.json"
      },
      {
        "category": "external",
        "summary": "Recommended Cybersecurity Best Practices",
        "url": "https://www.se.com/us/en/download/document/7EN52-0390/"
      }
    ],
    "title": "EcoStruxure\u2122 Power Monitoring Expert Software \u0026 EcoStruxure\u2122 Power Operation (EPO) and EcoStruxure\u2122 Power SCADA Operation (PSO)",
    "tracking": {
      "current_release_date": "2025-11-11T08:00:00.000Z",
      "generator": {
        "date": "2025-11-10T14:41:29.636Z",
        "engine": {
          "name": "Schneider Electric CSAF Generator",
          "version": "1.2"
        }
      },
      "id": "SEVD-2025-224-02",
      "initial_release_date": "2025-08-12T04:00:00.000Z",
      "revision_history": [
        {
          "date": "2025-08-12T04:00:00.000Z",
          "number": "1.0.0",
          "summary": "Original Release"
        },
        {
          "date": "2025-10-14T07:00:00.000Z",
          "number": "2.0.0",
          "summary": "Remediations are now available for all impacting CVEs listed below for EcoStruxure\u2122 Power Monitoring Expert (PME) 2023 \u0026 2024 \u0026 2024R2 and EcoStruxure\u2122 Power Operation (EPO) 2022 \u0026 2024 w/ Advanced Reporting and Dashboards Module. After further investigation, CVE-2025-54923 and CVE-2025-54925 do not impact EcoStruxure\u2122 Power Monitoring Expert (PME) 2023 and prior."
        },
        {
          "date": "2025-11-11T08:00:00.000Z",
          "number": "3.0.0",
          "summary": "Updated Affected Products and Version section to include PME 2023 R2. Updated the impacting CVEs for PME 2022, 2023, and 2023 R2. There have been remediation updates made for PME 2023, and 2023 R2."
        }
      ],
      "status": "final",
      "version": "3.0.0"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version",
                "name": "2022",
                "product": {
                  "name": "EcoStruxure\u2122 Power Monitoring Expert (PME) Version 2022",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Power Monitoring Expert (PME)"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "2023",
                "product": {
                  "name": "EcoStruxure\u2122 Power Monitoring Expert (PME) Version 2023",
                  "product_id": "2"
                }
              },
              {
                "category": "product_version",
                "name": "2023 R2",
                "product": {
                  "name": "EcoStruxure\u2122 Power Monitoring Expert (PME) Version 2023 R2",
                  "product_id": "20"
                }
              },
              {
                "category": "product_version",
                "name": "2023 R2 Hotfix_199767",
                "product": {
                  "name": "EcoStruxure\u2122 Power Monitoring Expert (PME) 2023 R2 Hotfix_199767",
                  "product_id": "14"
                }
              },
              {
                "category": "product_version",
                "name": "2023 R2 Hotfix_273686_release.12.0",
                "product": {
                  "name": "EcoStruxure\u2122 Power Monitoring Expert (PME) 2023 R2 Hotfix_273686_release.12.0",
                  "product_id": "15"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Power Monitoring Expert (PME)"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "2024",
                "product": {
                  "name": "EcoStruxure\u2122 Power Monitoring Expert (PME) Version 2024",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Power Monitoring Expert (PME)"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "2024 R2",
                "product": {
                  "name": "EcoStruxure\u2122 Power Monitoring Expert (PME) Version 2024 R2",
                  "product_id": "4"
                }
              },
              {
                "category": "product_version",
                "name": "Hotfix_279338_Release_2024R2",
                "product": {
                  "name": "EcoStruxure\u2122 Power Monitoring Expert (PME) Hotfix_279338_Release_2024R2",
                  "product_id": "16"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Power Monitoring Expert (PME)"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "2022",
                "product": {
                  "name": "EcoStruxure\u2122 Power Operation (EPO) Advanced Reporting and Dashboards Module Version 2022",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Power Operation (EPO)"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "2024",
                "product": {
                  "name": "EcoStruxure\u2122 Power Operation (EPO) Advanced Reporting and Dashboards Module Version 2024",
                  "product_id": "6"
                }
              }
            ],
            "category": "product_name",
            "name": "EcoStruxure\u2122 Power Operation (EPO)"
          },
          {
            "category": "product_name",
            "name": "Advanced Reporting and Dashboards Module",
            "product": {
              "name": "Advanced Reporting and Dashboards Module",
              "product_id": "9"
            }
          }
        ],
        "category": "vendor",
        "name": "Schneider Electric"
      }
    ],
    "relationships": [
      {
        "category": "optional_component_of",
        "full_product_name": {
          "name": "EcoStruxure\u2122 Power Operation (EPO) 2022 w/ Advanced Reporting and Dashboards Module",
          "product_id": "10"
        },
        "product_reference": "9",
        "relates_to_product_reference": "5"
      },
      {
        "category": "optional_component_of",
        "full_product_name": {
          "name": "EcoStruxure\u2122 Power Operation (EPO) 2024 w/ Advanced Reporting and Dashboards Module",
          "product_id": "11"
        },
        "product_reference": "9",
        "relates_to_product_reference": "6"
      },
      {
        "category": "installed_with",
        "full_product_name": {
          "name": "EcoStruxure\u2122 Power Operation (EPO) 2024 w/ Advanced Reporting and Dashboards Module installed with EcoStruxure\u2122 Power Monitoring Expert (PME) Version 2024 R2",
          "product_id": "12"
        },
        "product_reference": "11",
        "relates_to_product_reference": "4"
      },
      {
        "category": "installed_with",
        "full_product_name": {
          "name": "EcoStruxure\u2122 Power Operation (EPO) 2024 w/ Advanced Reporting and Dashboards Module installed with EcoStruxure\u2122 Power Monitoring Expert (PME) Version 2024",
          "product_id": "13"
        },
        "product_reference": "11",
        "relates_to_product_reference": "3"
      },
      {
        "category": "installed_with",
        "full_product_name": {
          "name": "EcoStruxure\u2122 Power Operation (EPO) 2022 w/ Advanced Reporting and Dashboards Module installed with EcoStruxure\u2122 Power Monitoring Expert (PME) Version 2024 R2",
          "product_id": "17"
        },
        "product_reference": "10",
        "relates_to_product_reference": "4"
      },
      {
        "category": "installed_with",
        "full_product_name": {
          "name": "EcoStruxure\u2122 Power Operation (EPO) 2022 w/ Advanced Reporting and Dashboards Module installed with EcoStruxure\u2122 Power Monitoring Expert (PME) Version 2024",
          "product_id": "18"
        },
        "product_reference": "10",
        "relates_to_product_reference": "3"
      },
      {
        "category": "installed_with",
        "full_product_name": {
          "name": "EcoStruxure\u2122 Power Operation (EPO) 2022 w/ Advanced Reporting and Dashboards Module installed with EcoStruxure\u2122 Power Monitoring Expert (PME) Version 2023",
          "product_id": "19"
        },
        "product_reference": "10",
        "relates_to_product_reference": "2"
      },
      {
        "category": "installed_with",
        "full_product_name": {
          "name": "EcoStruxure\u2122 Power Operation (EPO) 2022 w/ Advanced Reporting and Dashboards Module installed with EcoStruxure\u2122 Power Monitoring Expert (PME) Version 2023 R2",
          "product_id": "21"
        },
        "product_reference": "10",
        "relates_to_product_reference": "20"
      }
    ]
  },
  "vulnerabilities": [
    {
      "acknowledgments": [
        {
          "organization": "ZDI - Trend Micro Initiative"
        }
      ],
      "cve": "CVE-2025-54923",
      "cwe": {
        "id": "CWE-502",
        "name": "Deserialization of Untrusted Data"
      },
      "notes": [
        {
          "category": "description",
          "text": "CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution and\r\ncompromise of system integrity when authenticated users send crafted data to a network-exposed service that\r\nperforms unsafe deserialization.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "fixed": [
          "16"
        ],
        "known_affected": [
          "3",
          "4",
          "12",
          "13",
          "17",
          "18"
        ],
        "known_not_affected": [
          "1",
          "2",
          "19",
          "20",
          "21"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Hotfix_279338_Release_2024R2 is available for EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center for assistance applying this hotfix. In addition to applying the hotfixes noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "4"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Customers should upgrade to the latest product offering EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 and apply Hotfix_279338_Release_2024R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center for assistance with obtaining EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 and help applying this hotfix. In addition to applying the hotfix noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "3"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm Ensure PME is running in an isolated network. Deploy and configure the Windows firewall to limit access to appropriate network segments. Enforce complex password policies. Review Server Access Permissions: Conduct an audit of all Windows-authenticated users who currently have access to PME.  Repeat this audit of your system periodically. Identify all accounts with access rights, especially those with elevated privileges or remote access. Limit access to essential users. Revoke access for any user accounts that are not critical for system functionality or day-to-day operations. Apply the principle of least privilege to ensure users have only the access needed for their role",
          "product_ids": [
            "3",
            "4",
            "12",
            "13",
            "17",
            "18"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm"
        },
        {
          "category": "vendor_fix",
          "details": "Hotfix_279338_Release_2024R2 is available for EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center to determine if you are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 OR EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 as part of your solution. Customers running either of these versions of PME can work with Schneider Electric\u2019s Customer Care Center for assistance to upgrade PME and/or apply the hotfix. Note: Customers who are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 should upgrade to EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 then apply the hotfix.",
          "product_ids": [
            "12",
            "13",
            "17",
            "18"
          ],
          "restart_required": {
            "category": "none"
          }
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "3",
            "4",
            "12",
            "13",
            "17",
            "18"
          ]
        }
      ],
      "title": "CVE-2025-54923"
    },
    {
      "acknowledgments": [
        {
          "organization": "ZDI - Trend Micro Initiative"
        }
      ],
      "cve": "CVE-2025-54924",
      "cwe": {
        "id": "CWE-918",
        "name": "Server-Side Request Forgery (SSRF)"
      },
      "notes": [
        {
          "category": "description",
          "text": "CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to\r\nsensitive data when an attacker sends a specially crafted document to a vulnerable endpoint.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "fixed": [
          "14",
          "15",
          "16"
        ],
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "12",
          "13",
          "17",
          "18",
          "19",
          "20",
          "21"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Hotfix_279338_Release_2024R2 is available for EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center for assistance applying this hotfix. In addition to applying the hotfixes noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "4"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Customers should upgrade to the latest product offering EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 and apply Hotfix_279338_Release_2024R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center for assistance with obtaining EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 and help applying this hotfix. In addition to applying the hotfix noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "3"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Hotfix_279338_Release_2024R2 is available for EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center to determine if you are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 OR EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 as part of your solution. Customers running either of these versions of PME can work with Schneider Electric\u2019s Customer Care Center for assistance to upgrade PME and/or apply the hotfix. Note: Customers who are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 should upgrade to EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 then apply the hotfix.",
          "product_ids": [
            "12",
            "13",
            "17",
            "18"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Customers should upgrade to EcoStruxure\u2122 Power Monitoring Expert (PME) 2023 R2 and apply Hotfix_199767_release and Hotfix_273686_release.12.0 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, and CVE-2025-54927. Contact Schneider Electric\u2019s Customer Care Center for assistance applying these hotfixes. In addition to applying the hotfixes noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "2"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Hotfix_199767_release and Hotfix_273686_release.12.0 are available for EcoStruxure\u2122 Power Monitoring Expert (PME) that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, and CVE-2025-54927. Contact Schneider Electric\u2019s Customer Care Center for assistance applying these hotfixes. In addition to applying the hotfixes noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "20"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Hotfix_199767 and Hotfix_273686_release.12.0 is available for EcoStruxure\u2122 Power Monitoring Expert (PME) 2023R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, and CVE-2025-54927. Contact Schneider Electric\u2019s Customer Care Center to determine if you are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2023R2 as part of your solution. Customers running this version of PME can work with Schneider Electric\u2019s Customer Care Center for assistance applying this hotfix. OR Contact Schneider Electric\u2019s Customer Care Center to determine if you are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2023 as part of your solution. Customers running this version of PME can work with Schneider Electric\u2019s Customer Care Center for assistance upgrading to EcoStruxure\u2122 Power Monitoring Expert (PME) 2023 R2 and then help applying the hotfix.",
          "product_ids": [
            "19",
            "21"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm Ensure PME is running in an isolated network. Deploy and configure the Windows firewall to limit access to appropriate network segments. Enforce complex password policies. Review Server Access Permissions: Conduct an audit of all Windows-authenticated users who currently have access to PME.  Repeat this audit of your system periodically. Identify all accounts with access rights, especially those with elevated privileges or remote access. Limit access to essential users. Revoke access for any user accounts that are not critical for system functionality or day-to-day operations. Apply the principle of least privilege to ensure users have only the access needed for their role",
          "product_ids": [
            "2",
            "3",
            "4",
            "12",
            "13",
            "17",
            "18",
            "19",
            "20",
            "21"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm"
        },
        {
          "category": "mitigation",
          "details": "EcoStruxure\u2122 Power Monitoring Expert (PME) 2022 version has reached its end of life and is no longer supported. Customers should immediately apply the following mitigations to reduce the risk of exploit for CVE-2025-54924, CVE-2025-54925, and CVE-2025-54927:\u2022 Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm \u2022 Ensure PME is running in an isolated network \u2022 Deploy and configure the Windows firewall to limit access to appropriate network segments. \u2022 Enforce complex password policies. \u2022 Review Server Access Permissions \u2022 Conduct an audit of all Windows-authenticated users who currently have access to PME. Repeat this audit of your system periodically. \u2022 Identify all accounts with access rights, especially those with elevated privileges or remote access. \u2022 Limit access to essential users only. \u2022 Revoke access for any user accounts that are not critical for system functionality or daily operations. \u2022 Apply the principle of least privilege to ensure users have only the access necessary for their role(s). Customers should also consider upgrading to the latest product offering EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 to resolve this issue.",
          "product_ids": [
            "1"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "12",
            "13",
            "17",
            "18",
            "19",
            "20",
            "21"
          ]
        }
      ],
      "title": "CVE-2025-54924"
    },
    {
      "acknowledgments": [
        {
          "organization": "ZDI - Trend Micro Initiative"
        }
      ],
      "cve": "CVE-2025-54925",
      "cwe": {
        "id": "CWE-918",
        "name": "Server-Side Request Forgery (SSRF)"
      },
      "notes": [
        {
          "category": "description",
          "text": "CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to\r\nsensitive data when an attacker configures the application to access a malicious url.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "fixed": [
          "14",
          "15",
          "16"
        ],
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "12",
          "13",
          "17",
          "18",
          "19",
          "20",
          "21"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Hotfix_279338_Release_2024R2 is available for EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center for assistance applying this hotfix. In addition to applying the hotfixes noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "4"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Customers should upgrade to the latest product offering EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 and apply Hotfix_279338_Release_2024R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center for assistance with obtaining EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 and help applying this hotfix. In addition to applying the hotfix noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "3"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Hotfix_279338_Release_2024R2 is available for EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center to determine if you are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 OR EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 as part of your solution. Customers running either of these versions of PME can work with Schneider Electric\u2019s Customer Care Center for assistance to upgrade PME and/or apply the hotfix. Note: Customers who are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 should upgrade to EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 then apply the hotfix.",
          "product_ids": [
            "12",
            "13",
            "17",
            "18"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Customers should upgrade to EcoStruxure\u2122 Power Monitoring Expert (PME) 2023 R2 and apply Hotfix_199767_release and Hotfix_273686_release.12.0 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, and CVE-2025-54927. Contact Schneider Electric\u2019s Customer Care Center for assistance applying these hotfixes. In addition to applying the hotfixes noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "2"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Hotfix_199767_release and Hotfix_273686_release.12.0 are available for EcoStruxure\u2122 Power Monitoring Expert (PME) that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, and CVE-2025-54927. Contact Schneider Electric\u2019s Customer Care Center for assistance applying these hotfixes. In addition to applying the hotfixes noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "20"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Hotfix_199767 and Hotfix_273686_release.12.0 is available for EcoStruxure\u2122 Power Monitoring Expert (PME) 2023R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, and CVE-2025-54927. Contact Schneider Electric\u2019s Customer Care Center to determine if you are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2023R2 as part of your solution. Customers running this version of PME can work with Schneider Electric\u2019s Customer Care Center for assistance applying this hotfix. OR Contact Schneider Electric\u2019s Customer Care Center to determine if you are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2023 as part of your solution. Customers running this version of PME can work with Schneider Electric\u2019s Customer Care Center for assistance upgrading to EcoStruxure\u2122 Power Monitoring Expert (PME) 2023 R2 and then help applying the hotfix.",
          "product_ids": [
            "19",
            "21"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm Ensure PME is running in an isolated network. Deploy and configure the Windows firewall to limit access to appropriate network segments. Enforce complex password policies. Review Server Access Permissions: Conduct an audit of all Windows-authenticated users who currently have access to PME.  Repeat this audit of your system periodically. Identify all accounts with access rights, especially those with elevated privileges or remote access. Limit access to essential users. Revoke access for any user accounts that are not critical for system functionality or day-to-day operations. Apply the principle of least privilege to ensure users have only the access needed for their role",
          "product_ids": [
            "2",
            "3",
            "4",
            "12",
            "13",
            "17",
            "18",
            "19",
            "20",
            "21"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm"
        },
        {
          "category": "mitigation",
          "details": "EcoStruxure\u2122 Power Monitoring Expert (PME) 2022 version has reached its end of life and is no longer supported. Customers should immediately apply the following mitigations to reduce the risk of exploit for CVE-2025-54924, CVE-2025-54925, and CVE-2025-54927:\u2022 Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm \u2022 Ensure PME is running in an isolated network \u2022 Deploy and configure the Windows firewall to limit access to appropriate network segments. \u2022 Enforce complex password policies. \u2022 Review Server Access Permissions \u2022 Conduct an audit of all Windows-authenticated users who currently have access to PME. Repeat this audit of your system periodically. \u2022 Identify all accounts with access rights, especially those with elevated privileges or remote access. \u2022 Limit access to essential users only. \u2022 Revoke access for any user accounts that are not critical for system functionality or daily operations. \u2022 Apply the principle of least privilege to ensure users have only the access necessary for their role(s). Customers should also consider upgrading to the latest product offering EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 to resolve this issue.",
          "product_ids": [
            "1"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "12",
            "13",
            "17",
            "18",
            "19",
            "20",
            "21"
          ]
        }
      ],
      "title": "CVE-2025-54925"
    },
    {
      "acknowledgments": [
        {
          "organization": "ZDI - Trend Micro Initiative"
        }
      ],
      "cve": "CVE-2025-54926",
      "cwe": {
        "id": "CWE-22",
        "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
      },
      "notes": [
        {
          "category": "description",
          "text": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that\r\ncould cause remote code execution when an authenticated attacker with admin privileges uploads a malicious\r\nfile over HTTP which then gets executed.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "fixed": [
          "16"
        ],
        "known_affected": [
          "3",
          "4",
          "12",
          "13",
          "17",
          "18"
        ],
        "known_not_affected": [
          "1",
          "2",
          "19",
          "20",
          "21"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Hotfix_279338_Release_2024R2 is available for EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center for assistance applying this hotfix. In addition to applying the hotfixes noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "4"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Customers should upgrade to the latest product offering EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 and apply Hotfix_279338_Release_2024R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center for assistance with obtaining EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 and help applying this hotfix. In addition to applying the hotfix noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "3"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm Ensure PME is running in an isolated network. Deploy and configure the Windows firewall to limit access to appropriate network segments. Enforce complex password policies. Review Server Access Permissions: Conduct an audit of all Windows-authenticated users who currently have access to PME.  Repeat this audit of your system periodically. Identify all accounts with access rights, especially those with elevated privileges or remote access. Limit access to essential users. Revoke access for any user accounts that are not critical for system functionality or day-to-day operations. Apply the principle of least privilege to ensure users have only the access needed for their role",
          "product_ids": [
            "3",
            "4",
            "12",
            "13",
            "17",
            "18"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm"
        },
        {
          "category": "vendor_fix",
          "details": "Hotfix_279338_Release_2024R2 is available for EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center to determine if you are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 OR EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 as part of your solution. Customers running either of these versions of PME can work with Schneider Electric\u2019s Customer Care Center for assistance to upgrade PME and/or apply the hotfix. Note: Customers who are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 should upgrade to EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 then apply the hotfix.",
          "product_ids": [
            "12",
            "13",
            "17",
            "18"
          ],
          "restart_required": {
            "category": "none"
          }
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "3",
            "4",
            "12",
            "13",
            "17",
            "18"
          ]
        }
      ],
      "title": "CVE-2025-54926"
    },
    {
      "acknowledgments": [
        {
          "organization": "ZDI - Trend Micro Initiative"
        }
      ],
      "cve": "CVE-2025-54927",
      "cwe": {
        "id": "CWE-22",
        "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
      },
      "notes": [
        {
          "category": "description",
          "text": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that\r\ncould cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input\r\nthat is processed by the system.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "fixed": [
          "14",
          "15",
          "16"
        ],
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "12",
          "13",
          "17",
          "18",
          "19",
          "20",
          "21"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Hotfix_279338_Release_2024R2 is available for EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center for assistance applying this hotfix. In addition to applying the hotfixes noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "4"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Customers should upgrade to the latest product offering EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 and apply Hotfix_279338_Release_2024R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center for assistance with obtaining EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 and help applying this hotfix. In addition to applying the hotfix noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "3"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Hotfix_279338_Release_2024R2 is available for EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, CVE-2025-54926, CVE-2025-54927 and CVE-2025-54923. Contact Schneider Electric\u2019s Customer Care Center to determine if you are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 OR EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 as part of your solution. Customers running either of these versions of PME can work with Schneider Electric\u2019s Customer Care Center for assistance to upgrade PME and/or apply the hotfix. Note: Customers who are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 should upgrade to EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 then apply the hotfix.",
          "product_ids": [
            "12",
            "13",
            "17",
            "18"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Customers should upgrade to EcoStruxure\u2122 Power Monitoring Expert (PME) 2023 R2 and apply Hotfix_199767_release and Hotfix_273686_release.12.0 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, and CVE-2025-54927. Contact Schneider Electric\u2019s Customer Care Center for assistance applying these hotfixes. In addition to applying the hotfixes noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "2"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Hotfix_199767_release and Hotfix_273686_release.12.0 are available for EcoStruxure\u2122 Power Monitoring Expert (PME) that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, and CVE-2025-54927. Contact Schneider Electric\u2019s Customer Care Center for assistance applying these hotfixes. In addition to applying the hotfixes noted above, you are encouraged to review the mitigations listed below.",
          "product_ids": [
            "20"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "vendor_fix",
          "details": "Hotfix_199767 and Hotfix_273686_release.12.0 is available for EcoStruxure\u2122 Power Monitoring Expert (PME) 2023R2 that includes a fix for the vulnerabilities CVE-2025-54924, CVE-2025-54925, and CVE-2025-54927. Contact Schneider Electric\u2019s Customer Care Center to determine if you are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2023R2 as part of your solution. Customers running this version of PME can work with Schneider Electric\u2019s Customer Care Center for assistance applying this hotfix. OR Contact Schneider Electric\u2019s Customer Care Center to determine if you are running EcoStruxure\u2122 Power Monitoring Expert (PME) 2023 as part of your solution. Customers running this version of PME can work with Schneider Electric\u2019s Customer Care Center for assistance upgrading to EcoStruxure\u2122 Power Monitoring Expert (PME) 2023 R2 and then help applying the hotfix.",
          "product_ids": [
            "19",
            "21"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm Ensure PME is running in an isolated network. Deploy and configure the Windows firewall to limit access to appropriate network segments. Enforce complex password policies. Review Server Access Permissions: Conduct an audit of all Windows-authenticated users who currently have access to PME.  Repeat this audit of your system periodically. Identify all accounts with access rights, especially those with elevated privileges or remote access. Limit access to essential users. Revoke access for any user accounts that are not critical for system functionality or day-to-day operations. Apply the principle of least privilege to ensure users have only the access needed for their role",
          "product_ids": [
            "2",
            "3",
            "4",
            "12",
            "13",
            "17",
            "18",
            "19",
            "20",
            "21"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm"
        },
        {
          "category": "mitigation",
          "details": "EcoStruxure\u2122 Power Monitoring Expert (PME) 2022 version has reached its end of life and is no longer supported. Customers should immediately apply the following mitigations to reduce the risk of exploit for CVE-2025-54924, CVE-2025-54925, and CVE-2025-54927:\u2022 Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm \u2022 Ensure PME is running in an isolated network \u2022 Deploy and configure the Windows firewall to limit access to appropriate network segments. \u2022 Enforce complex password policies. \u2022 Review Server Access Permissions \u2022 Conduct an audit of all Windows-authenticated users who currently have access to PME. Repeat this audit of your system periodically. \u2022 Identify all accounts with access rights, especially those with elevated privileges or remote access. \u2022 Limit access to essential users only. \u2022 Revoke access for any user accounts that are not critical for system functionality or daily operations. \u2022 Apply the principle of least privilege to ensure users have only the access necessary for their role(s). Customers should also consider upgrading to the latest product offering EcoStruxure\u2122 Power Monitoring Expert (PME) 2024 R2 to resolve this issue.",
          "product_ids": [
            "1"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "12",
            "13",
            "17",
            "18",
            "19",
            "20",
            "21"
          ]
        }
      ],
      "title": "CVE-2025-54927"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…