SEVD-2023-010-06
Vulnerability from csaf_se - Published: 2023-01-10 15:17 - Updated: 2024-08-13 00:00Summary
EcoStruxure™ Control Expert, EcoStruxure™ Process Expert and Modicon M340, M580 and M580 CPU Safety
Notes
General Security Recommendations
We strongly recommend the following industry cybersecurity best practices.
https://www.se.com/us/en/download/document/7EN52-0390/
* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.
* Place all controllers in locked cabinets and never leave them in the “Program” mode.
* Never connect programming software to any network other than the network intended for that device.
* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.
* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.
* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.
For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.
For More Information
This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.
For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp
LEGAL DISCLAIMER
THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION
About Schneider Electric
At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.
We provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.
We are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.
www.se.com
Overview
Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure™ Control Expert , EcoStruxure™ Process Expert, Modicon M340, M580 and M580 CPU Safety. The Modicon M580 are PAC and Safety PLCs with built-in Ethernet for process, high availability & safety solutions.The Modicon M340 offers compactness, flexibility, scalability, and robustness for the process industry and a wide range of demanding automation applications. EcoStruxure™ Control Expert is the common programming, debugging and operating software forModicon PLCs (Programmable Logic Controllers) and PACs (Programmable Automation Controllers). The EcoStruxure™ Process Expert DCS is a single automation system to engineer, operate, and maintain your entire infrastructure for a sustainable, productive and market-agile plant.Failure to apply the mitigations provided below may risk unauthorized access to your PLC, which could result in the possibility of denial of service and loss of confidentiality, integrity of the controller. March 2023 Update: Modicon Momentum Unity M1E Process (page 6) and Modicon MC80 were added to the impacted products with the mitigations (page 7).
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure\u2122 Control Expert , EcoStruxure\u2122 Process Expert, Modicon M340, M580 and M580 CPU Safety. The Modicon M580 are PAC and Safety PLCs with built-in Ethernet for process, high availability \u0026 safety solutions.The Modicon M340 offers compactness, flexibility, scalability, and robustness for the process industry and a wide range of demanding automation applications. EcoStruxure\u2122 Control Expert is the common programming, debugging and operating software forModicon PLCs (Programmable Logic Controllers) and PACs (Programmable Automation Controllers). The EcoStruxure\u2122 Process Expert DCS is a single automation system to engineer, operate, and maintain your entire infrastructure for a sustainable, productive and market-agile plant.Failure to apply the mitigations provided below may risk unauthorized access to your PLC, which could result in the possibility of denial of service and loss of confidentiality, integrity of the controller. March 2023 Update: Modicon Momentum Unity M1E Process (page 6) and Modicon MC80 were added to the impacted products with the mitigations (page 7).",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "EcoStruxure\u2122 Control Expert, EcoStruxure\u2122 Process Expert and Modicon M340, M580 and M580 CPU Safety - SEVD-2023-010-06 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-06_Modicon_Controllers_Security_Notification.pdf"
},
{
"category": "self",
"summary": "EcoStruxure\u2122 Control Expert, EcoStruxure\u2122 Process Expert and Modicon M340, M580 and M580 CPU Safety - SEVD-2023-010-06 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2023-010-06.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/in/en/download/document/7EN52-0390/"
}
],
"title": "EcoStruxure\u2122 Control Expert, EcoStruxure\u2122 Process Expert and Modicon M340, M580 and M580 CPU Safety",
"tracking": {
"current_release_date": "2024-08-13T00:00:00.000Z",
"generator": {
"date": "2024-08-13T00:00:00.000Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2023-010-06",
"initial_release_date": "2023-01-10T15:17:09.000Z",
"revision_history": [
{
"date": "2023-01-10T15:17:09.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2023-03-14T06:30:00.000Z",
"number": "2.0.0",
"summary": "Modicon Momentum Unity M1E Process (page 6) and Modicon MC80 were added to the impacted products with the mitigations (page 7)."
},
{
"date": "2023-08-08T15:41:00.000Z",
"number": "3.0.0",
"summary": "All versions of the EcoStruxure\u2122 Process Expert are impacted by this vulnerability"
},
{
"date": "2024-01-09T00:00:00.000Z",
"number": "4.0.0",
"summary": "A remediation is available for Modicon M580"
},
{
"date": "2024-08-13T00:00:00.000Z",
"number": "5.0.0",
"summary": "A remediation is available for Modicon M580 CPU Safety(page 2)."
}
],
"status": "final",
"version": "5.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 Control Expert all versions",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Control Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 Process Expert All Versions",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Process Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric Modicon M340 CPU all versions",
"product_id": "3",
"product_identification_helper": {
"model_numbers": [
"BMXP34*"
]
}
}
}
],
"category": "product_name",
"name": "Modicon M340 CPU"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003csv4.20",
"product": {
"name": "Schneider Electric Modicon M580 CPU versions prior to sv4.20",
"product_id": "4",
"product_identification_helper": {
"model_numbers": [
"BMEP*",
"BMEH*"
]
}
}
}
],
"category": "product_name",
"name": "Modicon M580 CPU"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV4.21",
"product": {
"name": "Schneider Electric Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) Versions prior to SV4.21",
"product_id": "5",
"product_identification_helper": {
"model_numbers": [
"BMEP58*S",
"BMEH58*S"
]
}
}
}
],
"category": "product_name",
"name": "Modicon M580 CPU Safety"
},
{
"branches": [
{
"category": "product_version",
"name": "2021",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 Process Expert version 2021",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Process Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Modicon Momentum Unity M1E Processor all versions",
"product_id": "7",
"product_identification_helper": {
"model_numbers": [
"171CBU*"
]
}
}
}
],
"category": "product_name",
"name": "Modicon Momentum Unity M1E Processor"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Modicon MC80 all versions",
"product_id": "8",
"product_identification_helper": {
"model_numbers": [
"BMKC80"
]
}
}
}
],
"category": "product_name",
"name": "Modicon MC80"
},
{
"branches": [
{
"category": "product_version",
"name": "sv4.20",
"product": {
"name": "Schneider Electric Modicon M580 CPU version sv4.20",
"product_id": "9",
"product_identification_helper": {
"model_numbers": [
"BMEP*",
"BMEH*"
]
}
}
}
],
"category": "product_name",
"name": "Modicon M580 CPU"
},
{
"branches": [
{
"category": "product_version",
"name": "SV4.21",
"product": {
"name": "Schneider Electric Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) Version SV4.21",
"product_id": "10",
"product_identification_helper": {
"model_numbers": [
"BMEP58*S",
"BMEH58*S"
]
}
}
}
],
"category": "product_name",
"name": "Modicon M580 CPU Safety"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Daniel dos Santos",
"Jos Wetzels"
],
"organization": "Forescout Technologies"
}
],
"cve": "CVE-2022-45789",
"cwe": {
"id": "CWE-294",
"name": "Authentication Bypass by Capture-replay"
},
"notes": [
{
"category": "description",
"text": "A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could\r\ncause execution of unauthorized Modbus functions on the controller when hijacking an\r\nauthenticated Modbus session.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"9",
"10"
],
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"7",
"8"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Firmware SV4.21 includes a fix for this vulnerability and \r\nis available for download here: \r\nhttps://www.se.com/ww/en/product-range/62098-modicon-m580-pac-controller/#software-andfirmware \r\nImportant: customer needs to use version of \r\nEcoStruxure Control Expert v16.0 HF001 minimum to \r\nconnect with the latest version of M580 CPU Safety. \r\nThe software is available for download here: \r\nhttps://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#software-andfirmware",
"product_ids": [
"5"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/62098-modicon-m580-epac-controller/#software-and-firmware"
},
{
"category": "mitigation",
"details": "Schneider Electric is establishing a remediation plan for all future versions of EcoStruxure\u2122 Process Expert that will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit: \r\n \u2022 Setup a VPN between the Modicon PLC controllers and the engineering workstation containing EcoStruxureTM Process Expert. Note: this functionality may be provided by an external IPSEC compatible firewall located close to the controller. \r\n \u2022 Encrypt project files when stored and restrict the access to only trusted users. \r\n \u2022 When exchanging files over the network, use secure communication protocols.\r\n \u2022 Only open project files received from trusted source. \r\n\u2022 Compute a hash of the project files and regularly check the consistency of this hash to verify the integrity before usage. \r\n Harden the workstation running EcoStruxure\u2122 Process Expert.",
"product_ids": [
"2"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Schneider Electric is establishing a remediation plan for all future\r\nversions of EcoStruxure\u2122 Control Expert that will include a fix for\r\nthis vulnerability. We will update this document when the remediation\r\nis available. Until then, customers should immediately apply the\r\nfollowing mitigations to reduce the risk of exploit:\r\n\u2022 Setup a VPN between the Modicon PLC controllers and the\r\nengineering workstation containing EcoStruxureTM Control\r\nExpert. Note: this functionality may be provided by an\r\nexternal IPSEC compatible firewall located close to the\r\ncontroller.\r\n\u2022 Harden the workstation running EcoStruxure\u2122 Control\r\nExpert. \r",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Schneider Electric is establishing a remediation plan for all future\r\nversions of M340 Controllers that will include a fix for this\r\nvulnerability. We will update this document when the remediation is\r\navailable. Until then, customers should immediately apply the\r\nfollowing mitigations to reduce the risk of exploit:\r\n\u2022 Setup an application password in the project properties.\r\n\u2022 Setup network segmentation and implement a firewall to\r\nblock all unauthorized access to port 502/TCP.\r\n\u2022 Configure the Access Control List following the\r\nrecommendations of the user manuals:\r\no \u201cModicon M340 for Ethernet Communications\r\nModules and Processors User Manual\u201d in chapter\r\n\u201cMessaging Configuration Parameters\u201d:\r\nhttps://www.se.com/ww/en/download/document/31007131K01000/\r\n\u2022 Setup a secure communication according to the following\r\nguideline \u201cModicon Controllers Platform Cyber Security\r\nReference Manual,\u201d in chapter \u201cSetup secured communications\u201d:\r\nhttps://www.se.com/ww/en/download/document/EIO0000001999/\r\n\u2022 Consider the use of external firewall devices such as\r\nEAGLE40-07 from Belden to establish VPN connections for\r\nM340 \u0026 M580 architectures. For more details refer to the\r\nchapter \u201cHow to protect M580 and M340 architectures with\r\nEAGLE40 using VPN\u201d:\r\nhttps://www.se.com/ww/en/download/document/EIO0000001999/",
"product_ids": [
"3"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Firmware sv4.20 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware",
"product_ids": [
"4"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation, it is recommended to apply the following mitigations to reduce the risk of the exploit:\u2022 Setup an application password in the project properties. \u2022 Setup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP. \u2022 Configure the Access Control List following the recommendations of the user manuals: o \u201cModicon M580, Hardware, Reference Manual\u201d: https://www.se.com/ww/en/download/document/EIO0000001578/ \u2022 Setup a secure communication according to the following guideline \u201cModicon Controllers Platform Cyber Security Reference Manual,\u201d in chapter \u201cSetup secured communications\u201d: https://www.se.com/ww/en/download/document/EIO0000001999/ o use a BMENOC module and follow the instructions to configure IPSEC feature as described in the guideline \u201cModicon M580 - BMENOC03.1 Ethernet Communications Schneider Electric Security Notification Module, Installation and Configuration Guide\u201d in the chapter \u201cConfiguring IPSEC communications\u201d: https://www.se.com/ww/en/download/document/HRB62665/ OR \u2022 Use a BMENUA0100 module and follow the instructions to configure IPSEC feature as described in the chapter \u201cConfiguring the BMENUA0100 Cybersecurity Settings\u201d: https://www.se.com/ww/en/download/document/PHA83350 OR \u2022 Consider use of external firewall devices such as EAGLE40-07 from Belden to establish VPN connections for M340 \u0026 M580 architectures. For more details refer to the chapter \u201cHow to protect M580 and M340 architectures with EAGLE40 using VPN\u201d: https://www.se.com/ww/en/download/document/EIO0000001999/ \u2022 Ensure the M580 CPU is running with the memory protection activated by configuring the input bit to a physical input, for more details refer to the following guideline \u201cModicon Controllers Platform Cyber Security Reference Manual\u201d, \u201cCPU Memory Protection section\u201d: https://www.schneiderelectric.com/en/download/document/EIO0000001999/ o NOTE: The CPU memory protection cannot be configured with M580 Hot Standby CPUs. In such cases, use IPsec encrypted communication.",
"product_ids": [
"4"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation then they are encouraged to immediately apply the following mitigations to reduce the risk of exploit:\r\n\u2022 Setup an application password in the project properties.\r\n\u2022 Setup network segmentation and implement a firewall to\r\nblock all unauthorized access to port 502/TCP.\r\n\u2022 Configure the Access Control List following the\r\nrecommendations of the user manuals:\r\no \u201cModicon M580, Hardware, Reference Manual\u201d:\r\nhttps://www.se.com/ww/en/download/document/EIO0\r\n000001578/\r\n\u2022 Setup a secure communication according to the following\r\nguideline \u201cModicon Controllers Platform Cyber Security\r\nReference Manual,\u201d in chapter \u201cSetup secured\r\ncommunications\u201d:\r\nhttps://www.se.com/ww/en/download/document/EIO0000001\r\n999/\r\no use a BMENOC module and follow the instructions to\r\nconfigure IPSEC feature as described in the guideline\r\n\u201cModicon M580 - BMENOC03.1 Ethernet\r\nCommunications Schneider Electric Security\r\nNotification Module, Installation and Configuration\r\nGuide\u201d in the chapter \u201cConfiguring IPSEC\r\ncommunications\u201d: \r\nOR\r\n\u2022 Use a BMENUA0100 module and follow the instructions to\r\nconfigure IPSEC feature as described in the chapter\r\n\u201cConfiguring the BMENUA0100 Cybersecurity Settings\u201d:\r\nhttps://www.se.com/ww/en/download/document/PHA83350\r\nOR\r\n\u2022 Consider use of external firewall devices such as EAGLE40-\r\n07 from Belden to establish VPN connections for M340 \u0026\r\nM580 architectures. For more details refer to the chapter\r\n\u201cHow to protect M580 and M340 architectures with EAGLE40\r\nusing VPN\u201d:\r\nhttps://www.se.com/ww/en/download/document/EIO0000001\r\n999/\r\n\u2022 Ensure the M580 CPU is running with the memory protection\r\nactivated by configuring the input bit to a physical input, for\r\nmore details refer to the following guideline \u201cModicon\r\nControllers Platform Cyber Security Reference Manual\u201d,\r\n\u201cCPU Memory Protection section\u201d: https://www.schneiderelectric.com/en/download/document/EIO0000001999/\r\no NOTE: The CPU memory protection cannot be\r\nconfigured with M580 Hot Standby CPUs. In such\r\ncases, use IPsec encrypted communication.\r\nTo further reduce the attack surface on Modicon M580 CPU Safety:\r\no Ensure the CPU is running in Safety mode and\r\nmaintenance input is configured to maintain this\r\nSafety mode during operation \u2013 refer to the document\r\nModicon M580 - Safety System Planning Guide - in\r\nthe chapter \u201cOperating Mode Transitions\u201d:\r\nhttps://www.se.com/ww/en/download/document/QGH60283/",
"product_ids": [
"5"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Schneider Electric is establishing a remediation plan for all future versions of Modicon MOMENTUM Unity M1E controllers that will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit:\r\n\u2022 Setup an application password in the project properties\r\n\u2022 Setup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP\r\n\u2022 Configure the Access Control List following the recommendations of the user manuals:\u2022 \u201cMomentum for EcoStruxure\u2122 Control Expert \u2013 171 CBU 78090, 171 CBU 98090, 171 CBU 98091 Processors\u201d manual in the chapter \u201cModbus Messaging and Access Control\u201d: https://www.se.com/ww/en/download/document/HRB44124/\r\n\u2022 Setup a secure communication according to the following guideline \u201cModicon Controllers Platform Cyber Security Reference Manual,\u201d in chapter \u201cSetup secured communications\u201d: https://www.se.com/ww/en/download/document/EIO0000001999/",
"product_ids": [
"7"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Schneider Electric is establishing a remediation plan for all future versions of Modicon MC80 controllers that will include a fix for this vulnerability. We will update this document when the remediation is available. Until then, customers should immediately apply the following mitigations to reduce the risk of exploit:\r\n\u2022 Setup an application password in the project properties\r\n\u2022 Setup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP\r\n\u2022 Configure the Access Control List following the recommendations of the user manuals:\r\n\u2022 \u201cModicon MC80 Programmable Logic Controller (PLC) manual\u201d in the chapter \u201cAccess Control List (ACL)\u201d: https://www.se.com/ww/en/download/document/EIO0000002071/\r\n\u2022 Setup a secure communication according to the following guideline \u201cModicon Controllers Platform Cyber Security Reference Manual,\u201d in chapter \u201cSetup secured communications\u201d: https://www.se.com/ww/en/download/document/EIO0000001999/",
"product_ids": [
"8"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"7",
"8"
]
}
],
"title": "CVE-2022-45789"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.