Details
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2023-37552",
    "id": "GSD-2023-37552"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-37552"
      ],
      "details": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n",
      "id": "GSD-2023-37552",
      "modified": "2023-12-13T01:20:24.950553Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "info@cert.vde.com",
        "ID": "CVE-2023-37552",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "CODESYS Control for BeagleBone SL",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V4.10.0.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V4.10.0.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS Control for IOT2000 SL",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V4.10.0.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS Control for Linux SL",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V4.10.0.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS Control for PFC100 SL",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V4.10.0.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS Control for PFC200 SL",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V4.10.0.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS Control for PLCnext SL",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V4.10.0.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS Control for Raspberry Pi SL",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V4.10.0.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V4.10.0.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V3.5.19.20"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS Control RTE (SL)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V3.5.19.20"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS Control Runtime System Toolkit",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V3.5.19.20"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS Control Win (SL)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V3.5.19.20"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS Development System V3",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V3.5.19.20"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS HMI (SL)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V3.5.19.20"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "CODESYS Safety SIL2 Runtime Toolkit",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "V3.5.19.20"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "CODESYS"
            }
          ]
        }
      },
      "credits": [
        {
          "lang": "en",
          "value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.1.0-dev"
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-20",
                "lang": "eng",
                "value": "CWE-20 Improper Input Validation"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://cert.vde.com/en/advisories/VDE-2023-019/",
            "refsource": "MISC",
            "url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
          }
        ]
      },
      "source": {
        "advisory": "VDE-2023-019",
        "defect": [
          "CERT@VDE#64558"
        ],
        "discovery": "EXTERNAL"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.10.0.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.10.0.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.10.0.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.10.0.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.10.0.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.10.0.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.10.0.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.10.0.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.10.0.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "3.5.19.20",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "3.5.19.20",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "3.5.19.20",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "3.5.19.20",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "3.5.19.20",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "3.5.19.20",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "3.5.19.20",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "ID": "CVE-2023-37552"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "NVD-CWE-noinfo"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2023-019/",
              "refsource": "MISC",
              "tags": [
                "Third Party Advisory"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 3.6
        }
      },
      "lastModifiedDate": "2023-08-08T15:43Z",
      "publishedDate": "2023-08-03T12:15Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…